Chromalox Thermostat PK410 1 User Manual

Installation Instructions  
4
WR  
(Supersedes PK410)  
PK410-1  
161-048634-001  
JUNE, 1989  
Type WR Room Thermostat  
23/  
4
21/  
2
Note —  
WR-80 is  
not a  
Fail-Safe  
Device.  
6”  
53/  
8
21/  
2
29/16”  
WR-80  
40 to 80°F  
UL Listed  
21/  
4
WR-90  
20 to 90°F  
UL Listed  
Specifications – Table A  
Range  
Maximum Rating  
Model  
(°F)  
120Vac  
† 115Vac  
240Vac  
† 230Vac  
277Vac  
480Vac  
WR-80  
40-80  
125va pilot  
duty (use  
with d-c  
125va pilot  
duty (use  
with d-c  
125va pilot  
duty (use  
with a-c  
25 amps  
or 3000  
total watts  
22 amps  
or 5280  
total watts  
18 amps  
or 5000  
WR-90  
20-90  
contactor)  
contactor)  
total watts contactor)  
† d-c ratings not UL listed  
GENERAL  
Positive accuracy, long and reliable service, 3° differential.  
Heavy-duty, single stage, SPST line voltage snap-acting switch.  
Patented hydraulic element. WR-80 has internal sensing element  
and thermometer on cover; WR-90 has external, coiled sensing  
element but no thermometer. Both have a low position which  
drops control point to keep heater off. WR-80 and WR-90 fin-  
ished in tough metallic gray with chrome trim; mounting plate  
fits outlet or conduit box.  
Uses – Automatically controls room temperature by turning elec-  
tric air heaters on and off. Can be used to control the air heaters  
directly, within thermostat rating. For higher ratings use thermo-  
stat with magnetic contactor. Place thermostat on inside wall,  
away from undue heating or cooling influences, about 4 feet  
above the floor. WR-90 is especially useful in holding lower tem-  
peratures, for example, in garages, warehouses, factories, etc.  
NOTICE: Type WR thermostats are designed for temperature  
control service only. Because they do not fail safe, they should  
not be used for temperature limiting duty.  
CAUTION: Users should install adequate back-up controls and  
safety devices with their electric heating equipment. Where the  
consequences of failure may be severe, back-up controls are  
essential. Although the safety of the installation is the responsi-  
bility of the user, Chromalox will be glad to make equipment rec-  
ommendations.  
Principle of Operation – Control action of these thermostats is  
provided through the principle of liquid volume change. With a  
variation in temperature, the liquid in the sensing element  
expands or contracts, causing a bellows to actuate the switching  
mechanism.  
CAUTION: Not for use in hazardous environments  
as described in National Electrical Code. Failure to  
comply can result in explosion or fire.  
© 2010 Chromalox, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CALIBRATION  
SETTING  
WR-90 controls have an adjustable differential. The movable  
indicator points to the temperature at which the contacts open. The  
fixed indicator points to the temperature at which the contacts close.  
The difference between these two indicators is the differential.  
UNITING LIQUID IN THERMOMETER  
Sometimes the red liquid inside the thermometer on the WR-  
80 becomes separated during shipment. The thermometer will not  
read correctly when this red liquid is separated at any point. If the  
red liquid in the thermometer of this thermostat has become sepa-  
rated it may be reunited as follows:  
To set the control, proceed as follows:  
1. Remove the thermostat from the wall, and straighten out the  
four prongs so the cover can be removed to expose the ball of  
the thermometer.  
1. Use screwdriver in slot and turn the dial so the fixed indicator  
“B” points to the temperature at which heating is to start.  
2. Turn the differential adjusting screw “C” until the movable  
indicator “D” points to the temperature at which the heating is  
to stop.  
2. Hold the lighted end of a cigarette or a match at such a distance  
from the SIDE of the ball of the thermometer so the red liquid  
rises SLOWLY in the stem of the thermometer.  
3. When the lowest separation goes into the reservoir, immedi-  
ately remove the heat and blow on the thermometer.  
Figure 5  
Figure 4  
CAUTION: If there is more red liquid in the stem of the ther-  
mometer above the lowest separation than there is below it, it is  
best to replace the thermometer.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Limited Warranty:  
Please refer to the Chromalox limited warranty applicable to this product at  
1347 HEIL QUAKER BLVD., LAVERGNE, TN 37086  
Phone: (615) 793-3900  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Box Switch 24 Port Web Smart Gigabit Ethernet Switch User Manual
Bowers Wilkins Portable Speaker Signature 805 User Manual
Canon All in One Printer 2868B002 User Manual
Canon Camcorder 3i MC User Manual
Canon Camera Lens 9517A002 User Manual
Canon Printer BJC 1000 User Manual
Casio Cash Register PCR T2300 User Manual
Casio Digital Camera MA1006 A 1106 User Manual
Casio Watch QW 748 User Manual
Channel Plus Home Theater Server 9511BID Bamp;W User Manual