Chief Manufacturing Indoor Furnishings KSY220 User Manual

I N S T A L L A T I O N I N S T R U C T I O N S  
Universal Slat Wall  
Multi Arm Mount  
KSY220  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
KSY220  
LEGEND  
Pencil Mark  
Tighten Fastener  
Marcar con lápiz  
Stiftmarkierung  
Marcar com lápis  
Segno a matita  
Potloodmerkteken  
Marquage au crayon  
Apretar elemento de fijación  
Befestigungsteil festziehen  
Apertar fixador  
Serrare il fissaggio  
Bevestiging vastdraaien  
Serrez les fixations  
Drill Hole  
Loosen Fastener  
Perforar  
Aflojar elemento de fijación  
Befestigungsteil lösen  
Desapertar fixador  
Bohrloch  
Fazer furo  
Praticare un foro  
Gat boren  
Allentare il fissaggio  
Bevestiging losdraaien  
Desserrez les fixations  
Percez un trou  
Adjust  
Phillips Screwdriver  
Ajustar  
Destornillador Phillips  
Einstellen  
Ajustar  
Kreuzschlitzschraubendreher  
Chave de fendas Phillips  
Cacciavite a stella  
Regolare  
Afstellen  
Ajuster  
Kruiskopschroevendraaier  
Tournevis à pointe cruciforme  
Remove  
Quitar  
Open-Ended Wrench  
Llave de boca  
Entfernen  
Remover  
Rimuovere  
Verwijderen  
Retirez  
Gabelschlüssel  
Chave de bocas  
Chiave a punte aperte  
Steeksleutel  
Clé à fourche  
Optional  
Opcional  
Optional  
Opcional  
Opzionale  
Optie  
By Hand  
A mano  
Von Hand  
Com a mão  
A mano  
Met de hand  
À la main  
En option  
Security Wrench  
Hex-Head Wrench  
Llave de seguridad  
Sicherheitsschlüssel  
Chave de segurança  
Chiave di sicurezza  
Veiligheidssleutel  
Clé de sécurité  
Llave de cabeza hexagonal  
Sechskantschlüssel  
Chave de cabeça sextavada  
Chiave esagonale  
Zeskantsleutel  
Clé à tête hexagonale  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
KSY220  
Installation Instructions  
TOOLS REQUIRED FOR INSTALLATION  
1/8"  
(Provided)  
3/16"  
(Provided)  
5/32"  
(Provided)  
PARTS  
B (1)  
C (1)  
A (1)  
E (1)  
5/32"  
D (1)  
1/8"  
F (1)  
3/16"  
H (2)  
G (4)  
#8-32 X 3/8"  
J (2)  
M (2)  
UHMW  
P (2)  
K (4)  
N (2)  
L (2)  
5/16-18  
.320 x .563 x .018"  
Q (2)  
Q2 (4)  
.500 x .194 x .750  
Q3 (4)  
Q4 (4)  
Q5 (4)  
M4 x 30mm  
Q1 (4)  
.500 x .194 x .375  
M4 X 12mm  
M4 x 20mm  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
KSY220  
INSTALLATION  
(C) X 1  
WARNING: FAILURE TO PROVIDE ADEQUATE  
STRUCTURAL STRENGTH FOR THIS COMPONENT CAN  
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE  
TO EQUIPMENT! It is the installer’s responsibility to make  
sure the structure to which this component is attached can  
support five times the combined weight of all equipment.  
Reinforce the structure as required before installing the  
component.  
OFBU and Wall Plate Installation  
1. Install OFBU (C) following the instructions provided with the  
OFBU (C).  
3
IMPORTANT ! : If the display being installed has a recessed  
mounting surface, the display must be assembled to the mount  
prior to mount installation. See Display Installation in this  
document before proceeding.  
(B) X 1  
Figure 2  
2. Insert top of wall plate (B) over lip on top of OFBU bracket  
(C). (See Figure 1)  
4. Tighten set screw using 5/32" hex key (E). (See Figure 3)  
CAUTION: IMPROPER INSTALLATION CAN LEAD TO  
DISPLAY FALLING CAUSING SERIOUS PERSONAL  
INJURY OR DAMAGE TO EQUIPMENT! Make sure set  
screw engages back side of mounting dish on OFBU bracket  
(C). (See Figure 3)  
(C) X 1  
2
(C) X 1  
(B) X 1  
4
(B) X 1  
Figure 3  
Figure 1  
Swing Arm Installation  
1. Insert pivot pin (N) into Y-connector upper bore.  
3. Swing wall plate(B) downward until flush against OFBU  
bracket (C). (See Figure 2)  
2. Install spacer (L). (See Figure 4)  
3. Insert arm assembly (A) on pivot pin (N).  
4. While holding nut (P) in lower bore of Y-connector, insert  
screw (J) through washers (K), UHMW washer (M), arm  
assembly (A), spacer (L) and Y-connector, into nut (P). (See  
Figure 4)  
5. Loosely install screw (J) using 3/16" hex key (F).  
6. Repeat Steps 1. through 5. for second mount arm assembly  
(A).  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
KSY220  
Installation Instructions  
(J) X 2  
(K) X 4  
(M) X 2  
4
1
(L) X 2  
(A) X 2  
3
(N) X 2  
2
(P) X 2  
Figure 4  
in the previous step) with the two top teardrop mounting  
holes on the Centris cup.  
Display Installation  
The mounting holes on the back of the display will be flush with  
the back surface, or recessed into the back. Refer to the  
applicable installation procedure below.  
CAUTION: IMPROPER INSTALLATION CAN LEAD TO  
DISPLAY FALLING CAUSING SERIOUS PERSONAL  
INJURY OR DAMAGE TO EQUIPMENT! Smaller area of  
teardrop mounting holes must be facing downward for proper  
installation. Reposition Centris cup if required.  
Flush Mount Display Installation  
CAUTION: IMPROPER INSTALLATION CAN LEAD TO  
DISPLAY FALLING CAUSING SERIOUS PERSONAL  
INJURY OR DAMAGE TO EQUIPMENT! Using screws of  
improper size may damage your display! Proper screws will  
easily and completely thread into display mounting holes.  
(Q3) x 2  
2
CAUTION: IMPROPER INSTALLATION CAN LEAD TO  
DISPLAY FALLING CAUSING SERIOUS PERSONAL  
INJURY OR DAMAGE TO EQUIPMENT! Inadequate thread  
engagement in display may cause display to fall! Back out  
screws ONLY as necessary to allow installation of Centris  
bracket!  
3
1. Ensure Centris cup is able to swivel and tilt easily, yet still be  
tight enough to hold display in desired position. Adjust as  
required before proceeding. See "ADJUSTMENT" for  
detail.  
Centris Cup  
2. Using Phillips screwdriver, carefully install two screws (Q3)  
into the upper mounting holes on the display. Thread  
screws completely into display, then back out 3 complete  
turns.  
Figure 5  
4. Using Phillips screwdriver, install two screws (Q3) through  
the lower mounting holes in Centris cup into the display.  
5. Tighten all screws (Q3). Do not overtighten!  
3. Align two screws (Q3) (installed on the back of the display  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
KSY220  
Centris Cup  
Centris Cup  
(Q4 or Q5)  
(4 places)  
7
4
(Q3) x 2  
(Q1 or Q2)  
(4 places)  
5
Figure 6  
6. Repeat display installation procedures for second display.  
7. Proceed to "CABLE MANAGEMENT."  
Recessed Mount Display Installation  
Figure 7  
1. Ensure Centris bracket is able to swivel and tilt easily, yet  
still be tight enough to hold display in desired position.  
Adjust as required before proceeding. See  
"ADJUSTMENT" for detail.  
Cable Management  
1. Attach all cables to display.  
2. Carefully place display face down on a clean and dry  
surface.  
2. Open the cable management bracket by sliding it towards  
the edge of the arm (See Figure 8).  
3. Determine depth of recessed mounting holes relative to  
back surface of display.  
4. Select proper length spacer and screw from table below:  
NOTE: If necessary, cable management bracket attach screws  
may be loosened using hex key.  
IMPORTANT ! : All spacers used should be the same length.  
If the recess depths result in multiple spacer lengths, then  
select the longer spacer.  
IF recess DEPTH is: THEN use spacer:  
3/8" or less Q1 (3/8" long)  
AND screw:  
Q4 (M4 x 20mm)  
Q5 (M4 x 30mm)  
Attach  
Screws  
More than 3/8" up to Q2 (3/4" long)  
and including 3/4"  
5. Place the four spacers (Q1 or Q2) over each mounting hole  
on the back of display. (See Figure 7)  
6. Orient mount so that mounting holes in the Centris cup are  
aligned with the holes in the spacers (Q1 or Q2); rotate the  
Centris cup as required (See Figure 7).  
CLOSED Position  
View from Bottom  
OPEN Position  
CAUTION: IMPROPER INSTALLATION CAN LEAD TO  
DISPLAY FALLING CAUSING SERIOUS PERSONAL  
INJURY OR DAMAGE TO EQUIPMENT! Using screws of  
improper size may damage your display! Proper screws will  
easily and completely thread into display mounting holes.  
Figure 8  
CAUTION: Ensure that adequate cable slack exists for  
movement of display, and that cables will not be pinched  
when bracket is closed.  
7. Using Phillips screwdriver, install four screws (Q4 or Q5)  
through the mounting holes in Centris cup, through the  
spacers (Q1 or Q2), into display (See Figure 7).  
8. Tighten all four screws. Do not overtighten!  
9. Return to mount installation section to continue.  
10. Repeat display installation procedure for second display.  
3. Carefully insert cables into bracket (See Figure 9).  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
KSY220  
Installation Instructions  
2. Using Phillips screwdriver, slightly loosen or tighten  
the adjustment screw as necessary (See Figure 11).  
Adjustment Screw  
2
Cable Management  
Bracket (in open position)  
Cable Path (typical)  
Figure 11  
NOTE: Display not shown for clarity.  
3. Reinstall display. See Display Installation in this  
Figure 9  
document.  
4. Close cable management bracket by sliding it back towards  
the centerline of the arm (See Figure 8).  
Swing Arm Tension Adjustment  
1. Using 3/16" hex wrench (F), loosen or tighten adjustment  
screw(s) as necessary (See Figure 12).  
NOTE: If necessary, cable management bracket attach screws  
may be tightened using hex key.  
CAUTION: Ensure that adequate cable slack exists for  
movement of display, and that cables will not be pinched by  
installation of cover (H) or screws (G).  
5. Carefully insert cables in cavity located in lower portion of  
mount arm (See Figure 10).  
6. Using Phillips screwdriver, install cover (H) with two  
screws (G).  
Cable Path  
(typical)  
Figure 12  
(H) X 1  
(G) x 2  
Figure 10  
7. Repeat cable management procedures for second display.  
Adjustments  
Centris Head Tension Adjustment  
1. If previouslyattached, disconnect cables from display,  
remove display.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
KSY220  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
KSY220  
Installation Instructions  
USA/International  
Europe  
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378  
800.582.6480 / 952.894.6280  
877.894.6918 / 952.894.6918  
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands  
+31 (0)40 2668620  
+31 (0)40 2668615  
Asia Pacific  
A
Room 30I, Block D, Lily YinDu International Building  
LuoGang, BuJi Town, Shenzhen, CHINA. Post Code: 518112  
8832-000239 RevA  
¤2007 Chief Manufacturing  
12/07  
P
F
+86-755-8996 9226 ; 8996 9236 ; 8996 9220  
+86-755-8996 9217  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bowers Wilkins Home Theater System CT SW10 User Manual
Broan Range E6036SS User Manual
Bushnell Laser Pointer 201916 User Manual
Calibre UK Computer Monitor 6ID User Manual
Candy Washer CE 104 1 User Manual
Canon Digital Camera VB C50FSi User Manual
Capcom Video Games 13388330287 User Manual
CDA Cooktop HCC662 User Manual
Chicago Electric Automobile Battery Charger 96157 User Manual
Chromalox Electric Heater CAB User Manual