I N S T A L L A T I O N I N S T R U C T I O N S
Universal Slat Wall
Multi Arm Mount
KSY220
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
KSY220
LEGEND
Pencil Mark
Tighten Fastener
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Drill Hole
Loosen Fastener
Perforar
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Percez un trou
Adjust
Phillips Screwdriver
Ajustar
Destornillador Phillips
Einstellen
Ajustar
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Regolare
Afstellen
Ajuster
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Remove
Quitar
Open-Ended Wrench
Llave de boca
Entfernen
Remover
Rimuovere
Verwijderen
Retirez
Gabelschlüssel
Chave de bocas
Chiave a punte aperte
Steeksleutel
Clé à fourche
Optional
Opcional
Optional
Opcional
Opzionale
Optie
By Hand
A mano
Von Hand
Com a mão
A mano
Met de hand
À la main
En option
Security Wrench
Hex-Head Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
Llave de cabeza hexagonal
Sechskantschlüssel
Chave de cabeça sextavada
Chiave esagonale
Zeskantsleutel
Clé à tête hexagonale
3
Download from Www.Somanuals.com. All Manuals Search And Download.
KSY220
Installation Instructions
TOOLS REQUIRED FOR INSTALLATION
1/8"
(Provided)
3/16"
(Provided)
5/32"
(Provided)
PARTS
B (1)
C (1)
A (1)
E (1)
5/32"
D (1)
1/8"
F (1)
3/16"
H (2)
G (4)
#8-32 X 3/8"
J (2)
M (2)
UHMW
P (2)
K (4)
N (2)
L (2)
5/16-18
.320 x .563 x .018"
Q (2)
Q2 (4)
.500 x .194 x .750
Q3 (4)
Q4 (4)
Q5 (4)
M4 x 30mm
Q1 (4)
.500 x .194 x .375
M4 X 12mm
M4 x 20mm
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
KSY220
INSTALLATION
(C) X 1
WARNING: FAILURE TO PROVIDE ADEQUATE
STRUCTURAL STRENGTH FOR THIS COMPONENT CAN
RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE
TO EQUIPMENT! It is the installer’s responsibility to make
sure the structure to which this component is attached can
support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
OFBU and Wall Plate Installation
1. Install OFBU (C) following the instructions provided with the
OFBU (C).
3
IMPORTANT ! : If the display being installed has a recessed
mounting surface, the display must be assembled to the mount
prior to mount installation. See Display Installation in this
document before proceeding.
(B) X 1
Figure 2
2. Insert top of wall plate (B) over lip on top of OFBU bracket
(C). (See Figure 1)
4. Tighten set screw using 5/32" hex key (E). (See Figure 3)
CAUTION: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Make sure set
screw engages back side of mounting dish on OFBU bracket
(C). (See Figure 3)
(C) X 1
2
(C) X 1
(B) X 1
4
(B) X 1
Figure 3
Figure 1
Swing Arm Installation
1. Insert pivot pin (N) into Y-connector upper bore.
3. Swing wall plate(B) downward until flush against OFBU
bracket (C). (See Figure 2)
2. Install spacer (L). (See Figure 4)
3. Insert arm assembly (A) on pivot pin (N).
4. While holding nut (P) in lower bore of Y-connector, insert
screw (J) through washers (K), UHMW washer (M), arm
assembly (A), spacer (L) and Y-connector, into nut (P). (See
Figure 4)
5. Loosely install screw (J) using 3/16" hex key (F).
6. Repeat Steps 1. through 5. for second mount arm assembly
(A).
5
Download from Www.Somanuals.com. All Manuals Search And Download.
KSY220
Installation Instructions
(J) X 2
(K) X 4
(M) X 2
4
1
(L) X 2
(A) X 2
3
(N) X 2
2
(P) X 2
Figure 4
in the previous step) with the two top teardrop mounting
holes on the Centris cup.
Display Installation
The mounting holes on the back of the display will be flush with
the back surface, or recessed into the back. Refer to the
applicable installation procedure below.
CAUTION: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Smaller area of
teardrop mounting holes must be facing downward for proper
installation. Reposition Centris cup if required.
Flush Mount Display Installation
CAUTION: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Using screws of
improper size may damage your display! Proper screws will
easily and completely thread into display mounting holes.
(Q3) x 2
2
CAUTION: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Inadequate thread
engagement in display may cause display to fall! Back out
screws ONLY as necessary to allow installation of Centris
bracket!
3
1. Ensure Centris cup is able to swivel and tilt easily, yet still be
tight enough to hold display in desired position. Adjust as
required before proceeding. See "ADJUSTMENT" for
detail.
Centris Cup
2. Using Phillips screwdriver, carefully install two screws (Q3)
into the upper mounting holes on the display. Thread
screws completely into display, then back out 3 complete
turns.
Figure 5
4. Using Phillips screwdriver, install two screws (Q3) through
the lower mounting holes in Centris cup into the display.
5. Tighten all screws (Q3). Do not overtighten!
3. Align two screws (Q3) (installed on the back of the display
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
KSY220
Centris Cup
Centris Cup
(Q4 or Q5)
(4 places)
7
4
(Q3) x 2
(Q1 or Q2)
(4 places)
5
Figure 6
6. Repeat display installation procedures for second display.
7. Proceed to "CABLE MANAGEMENT."
Recessed Mount Display Installation
Figure 7
1. Ensure Centris bracket is able to swivel and tilt easily, yet
still be tight enough to hold display in desired position.
Adjust as required before proceeding. See
"ADJUSTMENT" for detail.
Cable Management
1. Attach all cables to display.
2. Carefully place display face down on a clean and dry
surface.
2. Open the cable management bracket by sliding it towards
the edge of the arm (See Figure 8).
3. Determine depth of recessed mounting holes relative to
back surface of display.
4. Select proper length spacer and screw from table below:
NOTE: If necessary, cable management bracket attach screws
may be loosened using hex key.
IMPORTANT ! : All spacers used should be the same length.
If the recess depths result in multiple spacer lengths, then
select the longer spacer.
IF recess DEPTH is: THEN use spacer:
3/8" or less Q1 (3/8" long)
AND screw:
Q4 (M4 x 20mm)
Q5 (M4 x 30mm)
Attach
Screws
More than 3/8" up to Q2 (3/4" long)
and including 3/4"
5. Place the four spacers (Q1 or Q2) over each mounting hole
on the back of display. (See Figure 7)
6. Orient mount so that mounting holes in the Centris cup are
aligned with the holes in the spacers (Q1 or Q2); rotate the
Centris cup as required (See Figure 7).
CLOSED Position
View from Bottom
OPEN Position
CAUTION: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Using screws of
improper size may damage your display! Proper screws will
easily and completely thread into display mounting holes.
Figure 8
CAUTION: Ensure that adequate cable slack exists for
movement of display, and that cables will not be pinched
when bracket is closed.
7. Using Phillips screwdriver, install four screws (Q4 or Q5)
through the mounting holes in Centris cup, through the
spacers (Q1 or Q2), into display (See Figure 7).
8. Tighten all four screws. Do not overtighten!
9. Return to mount installation section to continue.
10. Repeat display installation procedure for second display.
3. Carefully insert cables into bracket (See Figure 9).
7
Download from Www.Somanuals.com. All Manuals Search And Download.
KSY220
Installation Instructions
2. Using Phillips screwdriver, slightly loosen or tighten
the adjustment screw as necessary (See Figure 11).
Adjustment Screw
2
Cable Management
Bracket (in open position)
Cable Path (typical)
Figure 11
NOTE: Display not shown for clarity.
3. Reinstall display. See Display Installation in this
Figure 9
document.
4. Close cable management bracket by sliding it back towards
the centerline of the arm (See Figure 8).
Swing Arm Tension Adjustment
1. Using 3/16" hex wrench (F), loosen or tighten adjustment
screw(s) as necessary (See Figure 12).
NOTE: If necessary, cable management bracket attach screws
may be tightened using hex key.
CAUTION: Ensure that adequate cable slack exists for
movement of display, and that cables will not be pinched by
installation of cover (H) or screws (G).
5. Carefully insert cables in cavity located in lower portion of
mount arm (See Figure 10).
6. Using Phillips screwdriver, install cover (H) with two
screws (G).
Cable Path
(typical)
Figure 12
(H) X 1
(G) x 2
Figure 10
7. Repeat cable management procedures for second display.
Adjustments
Centris Head Tension Adjustment
1. If previouslyattached, disconnect cables from display,
remove display.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
KSY220
9
Download from Www.Somanuals.com. All Manuals Search And Download.
KSY220
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
+31 (0)40 2668615
Asia Pacific
A
Room 30I, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA. Post Code: 518112
8832-000239 RevA
¤2007 Chief Manufacturing
12/07
P
F
+86-755-8996 9226 ; 8996 9236 ; 8996 9220
+86-755-8996 9217
Download from Www.Somanuals.com. All Manuals Search And Download.
|