I N S T A L L A T I O N I N S T R U C T I O N S  
Vibration Mount  
Model CMA-347  
The Chief CMA-347 Vibration Mount is designed to  
dampen shock and vibration between a mounted item  
and its structural mounting surface.  
Any lengths of standard NPT 1 1/2” pipe, threaded on  
both ends, can be used to extend the height capabilities  
to meet your needs.  
BEFORE YOU BEGIN  
CAUTION: To prevent damage to the mount, which could void factory warranty and affect the attached equipment,  
thoroughly study all instructions and illustrations before you begin the installation. Pay particular attention to the  
“Important Warnings and Precautions” on Page 1.  
The maximum weight to be installed on the CMA-347 mount is 35 pounds (15.88 Kg).  
If you have any questions about this installation, contact Chief Manufacturing at 1-800-582-6480.  
8803-000044 (Rev. D)  
CHIEF MANUFACTURING INC.  
1-800-582-6480 952-894-6280 FAX 952-894-6918  
8401 EAGLE CREEK PARKWAY, STE 700  
SAVAGE, MINNESOTA 55378 USA  
¤2007 Chief Manufacturing  
09/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
Model CMA-347  
PARTS  
Item  
Nomenclature  
Qty  
.
Item  
Nomenclature  
Qty.  
10  
CMA-347 Top  
1
1
3
3
12  
3
6
3
3
6
3
3
130  
140  
150  
160  
170*  
180  
190  
200  
210  
WASHER, Fender, 1” OD  
24  
3
20  
CMA-347 Bottom  
NUT,Nylock, 3/8-16  
30  
WEIGHT, 2.5 Pound  
SCREW, Cap, Hex Head, 3/8-16 x 1.5”  
SCREW, Set, Socket Head, 5/16-18x3/8” (not shown)  
KEY, Hex, 5/32” (not shown)  
3
40  
DAMPER, Sorbothane, Stepped  
DAMPER, Sorbothane  
WASHER, Flat, 1/4”  
2
50  
1
60  
Plate, Ceiling, Projector Mounting (not shown or supplied)  
Pipe, Upper mounting, NPT 1 1/2" (not shown or supplied)  
Pipe, Lower Mounting, NPT 1 1/2" (not shown or supplied)  
Mount, Projector (not shown or supplied)  
1
1
1
1
70  
SPRING, Small  
80  
SPRING, Long Medium Gauge  
SPRING, Long Heavy Gauge  
BUSHING, Vibration, Stepped  
NUT, Nylock, 1/4-20  
90*  
100*  
110  
120  
BOLT, Hex Tap, 1/4-20 x 4”  
* Items 90 - 100 are included in the accessory pack and used when configuring mount for applications over 15lbs..  
Items 160 and 170 are located in the accessory pack and used in all applications to install the CMA-347 Vibration Mount.  
120  
60  
100  
120  
130  
(10)  
50  
15-35lb  
Applications  
130  
0-15lb  
Applications  
80  
130  
50  
90  
140  
130  
100  
130  
50  
130  
30  
70  
130  
50  
(20)  
40  
130  
150  
110  
Figure 1: CMA-347 Parts  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model CMA-347  
Installation Instructions  
lower mounting pipe (200).  
INSPECT MOUNT BEFORE INSTALLATION  
7. Thread projector mount (210) onto lower NPT 1 1/2"  
lower mounting pipe (200).  
1. Carefully inspect the mount for shipping damage  
(see figure 1). If any damage is apparent, call your  
carrier claims agent and do not continue with the  
installation until the carrier has reviewed the damage.  
8. Secure NPT 1 1/2” lower mounting pipe (200) to  
projector mount (210) following the installation  
instructions provided with the projector mount (210).  
NOTE: Read all assembly instructions before starting  
set-up or installation.  
9. With the weight of the installation on the CMA-347,  
tighten the 1/4-20 x 4" tap bolts until a slight preload  
is on the springs.  
2. Carefully inspect mount components for damage.  
MOUNT INSTALLATION  
The mount is shipped pre-assembled for applications  
under 15 pounds.  
CAUTION: If the total combined weight of the  
projector, projector mount, and lower mounting pipe  
exceeds 15lbs, the CMA 347 vibration mount needs to  
be reconfigured for weights over 15lbs. Weigh all parts  
before beginning installation.  
Ceiling Plate (180)  
NPT 1 1/2"  
Upper Mounting Pipe (190)  
If the total combined weight of the projector, projector  
mount, and lower mounting pipe is 15lbs or below,  
proceed with mount installation. If the total combined  
weight of the projector, projector mount, and lower  
mounting pipe is over 15lbs, see Set-Up for Over 15 lbs  
on page 6.  
CMA 347 Vibration Mount  
5/16-18 x 3/8"  
Socket Head  
Set Screw  
(160)  
NOTE: Keep the vibration mount as close as possible to  
the projector by minimizing the length of the lower  
mounting pipe.  
5/16-18 x 3/8"  
Socket Head  
Set Screw  
(160)  
1. Thread Upper mounting pipe (190) into Ceiling plate  
(180).  
NPT 1 1/2"  
Lower Mounting Pipe  
(200)  
2. Secure NPT 1 1/2” upper mounting pipe (190) to  
ceiling plate (180) following the installation  
instructions provided with the ceiling plate (180).  
3. Thread mount top (10) onto NPT 1 1/2” upper  
mounting pipe (190).  
Projector Mount (210)  
NOTE: Ensure there is no direct contact between mount  
and surrounding structure. Any contact could  
allow vibration transfer to the projector.  
Figure 2: CMA 347 Vibration Mount Installation  
4. Secure NPT 1 1/2” upper mounting pipe (190) to  
mount top (10) using 5/16-18 x 3/8" socket head set  
screw (160). Turn 5/16/18 x 3/8" socket head set  
screw (160) until it contacts thread of NPT 1 1/2”  
upper mounting pipe (190).  
5. Thread NPT 1 1/2” lower mounting pipe (200) into  
mount bottom (20).  
6. Secure NPT 1 1/2” lower mounting pipe (200) to  
mount bottom (20) using 5/16-18 x 3/8" socket head  
set screw (160). Turn 5/16/18 x 3/8" socket head set  
screw (160) until it contacts thread of NPT 1 1/2”  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
Model CMA-347  
Set-Up  
Set-up For 15 Pounds and Under  
(120)  
(60)  
The mount is shipped pre-assembled for applications  
under 15 pounds. If the total combined weight of the  
projector, projector mount, and lower mounting pipe is  
15lbsorbelow,proceedwithmount installation.  
(see MOUNT INSTALLATION on page 4)  
(10)  
(100)  
A
(90)  
For applications over 15 pounds, proceed to “Set-up For  
Over 15 Pounds”.  
(100)  
If the mount has been previously set-up to accommodate  
a weight of 15-35lbs, it needs to be reconfigured to work  
properly with weights below 15lbs.  
(20)  
B
To set-up the mount for applications under 15lbs:  
1. Un-install mount following the instructions outlined in  
the Removal section of this document.  
(40)  
(130)  
(see Mount Removal on page 7)  
(110)  
2. Loosen and remove 1/4-20 Nylock nut (110), 1/4"  
fender washer (130), and stepped sorbothane  
damper (40) located underneath mount arm and set  
aside for reuse. (see figure 3)  
Figure 3: Remove 35lb-15lb Application Hardware.  
3. Slide 1/4-20 x 4" tap bolt (120) upward, out of mount  
top (10).  
(120)  
(130)  
NOTE: Make cetrtain hardware group B (see figure 3)  
and (see figure 4) stays in place when removing  
1/4-20 x 4" tap bolt (120) and associated  
hardware.  
(50)  
(10)  
(130)  
(80)  
(130)  
(50)  
4. Remove hardware group A (see figure 3) keeping  
1/4-20 x tap bolt (120) for reuse in 0-15lb  
configuration.  
(130)  
(50)  
(130)  
5. Install 1/4" fender washers (130), sorbothane  
dampers (50), and long medium gauge spring (80),  
onto 1/4-20 x 4" tap bolt (120). (see figure 4)  
B
(70)  
(130)  
(50)  
(20)  
6. Insert 1/4-20 x 4" tap bolt (120) with washers and  
dampers through mount top (10), group B hardware  
(see figure 6), and mount bottom (20). (see figure 4)  
(40)  
(130)  
(110)  
7. Install stepped sorbothane damper (40), fender  
washer (130), and Nylock nut (110) onto 1/4-20 x 4"  
tap bolt (120). (see figure 4)  
8. Tighten until a slight preload is on the springs.  
Figure 4: Install 0-15lb Application Hardware.  
Repeat steps 2 through 8 for the remaining two hardware  
sets.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model CMA-347  
Installation Instructions  
Set-up For Over 15 Pounds  
The mount is shipped pre-assembled for applications  
under 15 pounds.  
(120)  
(130)  
(50)  
If the mount is set-up to accommodate a weight of up to  
15lbs (as shipped), it needs to be reconfigured to work  
properly with weights over 15lbs.  
(10)  
A
(130)  
WARNING: DO NOT attempt to reconfigure the mount  
while installed. Properly un-install mount and place on  
a flat stable surface before performing the procedure  
below.  
(80)  
(130)  
(50)  
(130)  
(50)  
To set-up the mount for applications over 15lbs:  
1. Un-install mount following the instructions outlined in  
the Removal section of this document.  
B
(70)  
(20)  
(130)  
(50)  
2. Loosen and remove 1/4-20 Nylock nut (110), 1/4"  
fender washer (130), and stepped sorbothane  
damper (40) located underneath mount arm and set  
aside for reuse. (see figure 5)  
(40)  
(130)  
(110)  
3. Slide 1/4-20 x 4" tap bolt (120) upward, out of mount  
top (10).  
NOTE: Make cetrtain hardware group B (see figure 5)  
stays in place when removing 1/4-20 x 4" tap bolt  
(120) and associated hardware.  
Figure 5: Remove 0-15lb Application Hardware.  
4. Remove hardware group A (see figure 5) keeping  
1/4-20 x tap bolt (120) for reuse in 15lb-35lb  
configuration.  
(120)  
(60)  
(10)  
(100)  
5. Install 1/4" machine washer (60), stepped dampers  
(100), and long heavy gauge spring (90), onto 1/4-20  
x 4" tap bolt (120).  
(see figure 6)  
(90)  
6. Insert 1/4-20 x 4" tap bolt (120) with washers and  
dampers through mount top (10), group B hardware  
(see figure 6), and mount bottom (20). (see figure 6)  
(100)  
(20)  
7. Install stepped sorbothane damper (40), fender  
washer (130), and Nylock nut (110) onto 1/4-20 x 4"  
tap bolt (120).  
B
8. Tighten all the parts installed in Step 1, Step 2 and  
Step 3 using a 1/4-20 x 4” tap bolt (120) and 1/4-20  
Nylock nut (110) until a slight preload is on the  
springs.  
(40)  
(130)  
(110)  
NOTE: Repeat steps 2 through 8 for the remaining two  
hardware sets.  
Figure 6: Install 15lb-35lb Application Hardware.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
Model CMA-347  
Mount Removal  
To remove the CMA 347 vibration mount:  
1. Disonnect power cables and wires from projector.  
NPT 1 1/2"  
Upper Mounting Pipe  
(190)  
2. Uninstall projector from projector mount (210).  
3. Uninstall projector mount (210) from NPT 1 1/2” lower  
mounting pipe (200) following the instructions  
provided with the projector mount (210)  
4. Loosen 5/16-18 x 3/8" socket head set screw (160)  
securing NPT 1 1/2” lower mounting pipe (200) to  
mount bottom (20).  
CMA 347 Vibration Mount  
5/16-18 x 3/8"  
Socket Head  
Set Screw  
(160)  
5. Uninstall NPT 1 1/2” lower mounting pipe (200) from  
mount bottom (20) by turning NPT 1 1/2” lower  
mounting pipe (200) counterclockwise.  
6. Loosen 5/16-18 x 3/8" socket head set screw (160)  
securing mount top (10) to NPT 1 1/2” upper mounting  
pipe (190).  
5/16-18 x 3/8"  
Socket Head  
Set Screw  
(160)  
NPT 1 1/2"  
Lower Mounting Pipe  
(200)  
7. Uninstall vibration mount from NPT 1 1/2” upper  
mounting pipe (190) by turning mount top (10)  
counterclockwise.  
Projector Mount  
(210)  
Figure 7: CMA 347 Vibration Mount Removal  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Belkin Network Card F8T017 User Manual
Binatone Cordless Telephone 2925 User Manual
Bissell Carpet Cleaner 1200, 7887 User Manual
Black Box Network Router MDR210A 485 User Manual
Black Decker Coffeemaker KE2000SD User Manual
Bolens Log Splitter 24638B User Manual
Bosch Appliances Security Camera EX27 User Manual
Candy Washer CBL140 User Manual
Carrier Stove 48KHA User Manual
Centro Gas Grill 85 1095 6 User Manual