BEFORE YOU BEGIN  
What is included  
1 x LED-RAIN36  
1 x Power cable (1 m) and 1 x Linking cable (1.5 m)  
Warranty Card  
Users Manual  
Unpacking Instructions  
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that  
all parts are present, and have been received in good condition. Notify the shipper immediately and  
retain packing material for inspection if any parts appear damaged from shipping or the carton itself  
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture  
must be returned to the factory, it is important that the fixture be returned in the original factory box  
and packing.  
AC Power  
To determine the power requirements for a particular product, see the label affixed to the back plate  
of the product or refer to the products specifications chart. A products listed current rating is its  
average current draw under normal conditions. All fixtures must be powered directly off a switched  
circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit,  
AC Voltage Switch Example  
even if the rheostat or dimmer channel is used solely for a 0% to 100%  
switch. Before applying power, check that the source voltage matches the  
products requirement. Check the product or device carefully to make sure  
that if a voltage selection switch exists that it is set to the correct line  
voltage you will use.  
Warning!  
If applicable, verify that the power select switch on your unit matches the line  
voltage applied. All fixtures must be connected to circuits with a suitable Earth  
Ground.  
Safety Instructions  
Please read these instructions carefully, which includes important  
information about the installation, usage and maintenance?  
Please keep this User Guide for future consultation. If you  
sell the unit to another user, be sure that they also receive  
this instruction booklet.  
Secure fixture to fastening device using a safety chain.  
Never carry the fixture solely by its head. Use its carrying  
handles.  
Always make sure that you are connecting to the proper  
voltage and that the line voltage you are connecting to is  
not higher than that stated on decal or rear panel of the  
fixture.  
Maximum ambient temperature is Ta: 40°. Do not operate  
fixture at temperatures higher than this.  
In the event of serious operating problem, stop using the  
unit immediately. Never try to repair the unit by yourself.  
Repairs carried out by unskilled people can lead to  
damage or malfunction. Please contact the nearest  
authorized technical assistance center. Always use the  
same type spare parts.  
This product is intended for indoor use only!  
To prevent risk of fire or shock, do not expose fixture to  
rain or moisture. Make sure there are no flammable  
materials close to the unit while operating.  
Dont connect the device to a dimmer pack.  
The unit must be installed in a location with adequate  
ventilation, at least 50cm from adjacent surfaces. Be sure  
that no ventilation slots are blocked.  
Make sure power cord is never crimped or damaged.  
Never disconnect power cord by pulling or tugging on the  
cord.  
Always disconnect from power source before servicing or  
replacing lamp or fuse and be sure to replace with same  
lamp source.  
Avoid direct eye exposure to lamp while it is on.  
Caution!  
There are no user serviceable parts inside the unit. Do not open the housing or  
attempt any repairs yourself. In the unlikely event your unit may require service,  
please contact CHAUVET.  
LED-RAIN36 User Manual  
3
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Features  
CONTROL FEATURES  
2-channel DMX-512 LED pinspot  
Dimmer/Strobe  
FEATURES  
86 white LEDs per surface  
Ultra bright LEDs  
Built in strobe program  
Low power consumption  
Up to 100,000-hour LED life span  
Master/Slave mode  
OPTIONS  
Programmable: Any universal DMX-512 controller  
DMX Channel Summary  
CHANNEL  
1
INTENSITY CONTROL OF  
Dimmer  
Strobe  
2
LED-RAIN36 User Manual  
4
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Overview  
DMX Connectors  
DMX dipswitches:  
DMX channel addressing  
Power link  
AC Voltage Switch  
Power connection  
Fuse  
Hanging yoke  
LED-RAIN36 User Manual  
5
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETUP  
Power  
Warning!  
Verify that the power indicator label on your unit matches the line voltage applied.  
All fixtures must be connected to circuits with a suitable Earth Ground.  
To determine the power requirements for a particular fixture, see the label affixed to the back plate  
of the fixture or refer to the fixtures specifications chart.  
A fixtures listed current rating is its average current draw under normal conditions.  
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat  
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0%  
to 100% switch.  
Before applying power to a fixture, check that the source voltage matches the fixtures  
requirement.  
All fixtures must be connected to circuits with a suitable Earth Ground.  
Power Cable Configuration  
CABLE  
BROWN  
PIN  
Live  
INTERNATIONAL  
L
N
BLUE  
Neutral  
Earth  
YELLOW/GREEN  
EG (Ground)  
Mounting  
Optional Hanging Clamp  
Orientation  
This fixture can be mounted on a truss using a clamp in any position.  
Rigging  
The fixture includes a mounting yoke to which 1 rigging clamp can be bolted.  
1. Align the clamp screw with the center hole on the yoke and tighten.  
2. Verify the structure can hold 10 times the weight of all to-be installed fixtures.  
3. Adjust the angle on the yoke arm as necessary.  
LED-RAIN36 User Manual  
6
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
The LED-RAIN36 is a DMX-512 controllable, pinspot made up of highly efficient and super bright  
white LEDs. The LED-RAIN36 can operate in Stand-Alone, Master/Slave and via DMX-512 control  
utilizing 2 channels.  
Master/Slave & Stand-Alone Mode  
The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In  
this mode, the first unit in the daisy chain will automatically command all other units following.  
DMX512  
OUT  
1. Connect all LED-RAIN36 units in a daisy  
chain fashion as described in the section  
following.  
IN  
ON  
POWER  
IN AC  
Master Setting  
POWER  
OUT AC  
FUSE  
2. Master Unit: Set dipswitch #10 to OFF.  
3. Slaves: Set dipswitch # 10 to the ON position  
and all others to the OFF position.  
DMX512  
IN  
OUT  
4. You can also run the fixtures in an automatic  
stand-alone mode by simply setting all  
fixtures to run as master units.  
ON  
Slave Setting  
POWER  
OUT AC  
POWER  
IN AC  
FUSE  
Daisy Chain Connection  
1. Connect the (male) 3 pin connector side of  
the DMX cable to the output (female) 3 pin connector of the first fixture.  
2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin  
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then,  
proceed to connect from the output as stated above to the input of the following fixture and so on.  
Continue  
Optional DMX Controller  
Use 3-pin XLR DMX cable  
DMX512  
DMX512  
DMX512  
DMX512  
OUT  
IN  
OUT  
IN  
OUT  
IN  
OUT  
IN  
O
N
O
N
O
N
O
N
C.  
C
POWER  
POWER  
POWER  
POWER  
POWER  
POWER  
POWER  
POWER  
FUSE  
FUSE  
FUSE  
FUSE  
OUT AC  
OUT AC  
OUT AC  
OUT AC  
IN AC  
IN AC  
IN AC  
IN AC  
AC Line  
Continue  
Use AC linking cable for convenience. As many as 50 par cans  
can be powered from one AC daisy chain connection.  
LED-RAIN36 User Manual  
7
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Built-in Program Options  
There are 2 main programs that can be adjusted  
by turning ON dipswitches 1 through 8 as  
illustrated next. Dipswitch # 10 must be set to  
OFF.  
Dipswitches 1 ~ 8  
(adjusts either speed or intensity)  
ON  
Manual Control Options  
DIPSWITCHES (ON)  
ADJUSTMENT  
PROGRAM FUNCTION  
Light Intensity  
(0%) - - - - - (100%)  
1
2
3
4
5
6
7
8
>
>>  
>>>  
>>>>  
>>>>>  
>>>>>>  
>>>>>>>  
>>>>>>>>  
Solid, very narrow beam  
Strobe Speed  
(Min)- - - - - (Max)  
9 & 8  
9 & 7  
9 & 6  
9 & 5  
9 & 4  
9 & 3  
9 & 2  
9 & 1  
9
>
>>  
>>>  
>>>>  
>>>>>  
>>>>>>  
>>>>>>>  
>>>>>>>>  
>>>>>>>>>  
Strobing  
Only the number of  
the dipswitch listed  
in this column is  
turned ON all others  
remain OFF  
LED-RAIN36 User Manual  
8
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DMX Control Mode  
Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to  
customizing or creating a show. In this mode you will be able to control each individual trait of the  
fixture and each fixture independently. The LED-RAIN36 uses 2 channels of control.  
1. Enable DMX control by setting dipswitch # 10 to the ON position. Use dipswitches 1 through 9 to  
address each fixture accordingly.  
Setting the DMX address  
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start  
address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data  
on the channel indicated by the start address. For example, a fixture that occupies or uses 7 channels  
of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101,  
102, 103, 104, 105 and 106. Choose start addresses so that the channels used do not overlap and  
notate the start address selected for future reference.  
If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping  
to the Appendix Section and read the heading DMX Primer. It contains very useful information that  
will help you understand its use.  
Set the start address using the group of DIP switches located usually on bottom of the fixture. Each  
dip switch has an associated value. Adding the value of each switch in the ON position will provide  
the start address. Determining which switches to toggle ON given a specific start address can be  
accomplished in the following manner. By subtracting the largest switch value possible from the  
selected start address until zero is achieved.  
EXAMPLE STARTING ADDRESS  
Address 10  
ON  
Pin # 4 = 8  
Pin # 2 = 2  
Total  
= 10  
Address 24  
ON  
Pin # 5 = 16  
Pin # 4 = 8  
Total  
= 24  
233 (128) = 105, Turn ON Dip # 8  
105 (64) = 41, Turn ON Dip # 7  
41 (32) = 9, Turn ON Dip # 6  
9 (8) = 1, Turn ON Dip # 4  
DIP SWITCH  
(DMX VALUE)  
1
2
1
2
Resolving address using  
simple math.  
1 (1) = 0, Turn ON Dip # 1  
3
4
4
5
6
7
8
9
8
You will most likely use the first  
available number which maybe  
number 1. This number was  
selected for example purposes.  
16  
32  
64  
128  
256  
Address 233  
10  
LED-RAIN36 User Manual  
9
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPENDIX  
DMX Primer  
There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A  
fixture capable of receiving DMX-512 will require one or a number of sequential channels. The user  
must assign a starting address on the fixture that indicates the first channel reserved in the controller.  
There are many different types of DMX controllable fixtures and they all may vary in the total number  
of channels required. Choosing a start address should be planned in advance. Channels should  
never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is  
set incorrectly. You can however, control multiple fixtures of the same type using the same starting  
address as long as the intended result is that of unison movement or operation. In other words, the  
fixtures will be slaved together and all respond exactly the same.  
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is  
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which  
the fixtures are connected is not important and has no effect on how a controller communicates to  
each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures  
using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The  
shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET  
carries 3-pin XLR DMX compliant cables, DMX-10 (33), DMX-4.5 (15) and DMX-1.5 (5)  
Fixture Linking  
DMX connector configuration  
Resistance 120  
1
ohm 1/4w between  
3
pin 2 (DMX -) and  
pin 3 (DMX +) of  
2
COMMON  
the last fixture.  
1
1
3
DMX +  
DMX -  
INPUT  
3
OUTPUT  
Termination reduces signal errors and to  
avoid signal transmission problems and  
interference, it is always advisable to  
connect a DMX signal terminator.  
2
2
Note!  
If you use a controller with a 5 pin DMX output connector, you will need to use a 5  
pin to 3 pin adapter. CHAUVET Model No: DMX5M.  
The chart below details a proper cable conversion:  
3 PIN TO 5 PIN CONVERSION CHART  
Conductor  
Ground/Shield  
Data ( - )signal  
Data ( + ) signal  
Do not use  
3 Pin Female (output)  
5 Pin Male (Input)  
Pin 1  
Pin 1  
Pin 2  
Pin 3  
Pin 2  
Pin 3  
Do not use  
Do not use  
Do not use  
LED-RAIN36 User Manual  
10  
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DMX Channel Values  
DEFAULT  
1
VALUE  
FUNCTION  
Dimmer  
000 255  
000 255  
Intensity: 0% > 100%  
Strobe (fps)  
Min > Max  
2
Returns Procedure  
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.  
Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products  
returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the  
fixture. Be prepared to provide the model number, serial number and a brief description of the cause  
for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate  
packaging is the customers responsibility. CHAUVET reserves the right to use its own discretion to  
repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe  
method to use.  
Claims  
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be  
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and  
submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim  
for items such as missing component/part, damage not related to shipping, and concealed damage,  
must be made within seven (7) days of receiving merchandise.  
LED-RAIN36 User Manual  
11  
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DMX Dipswitch Quick Reference Chart  
DMX Address Quick Reference Chart  
Dip Switch Position  
DMX DIP SWITCH SET #9  
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
0=OFF  
1=ON  
#8  
#7  
#6  
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
X=OFF or ON  
#1 #2 #3 #4 #5  
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
32 64  
33 65  
34 66  
35 67  
96  
97  
98  
99  
128  
129  
130  
131  
132  
133  
134  
135  
136  
137  
138  
139  
140  
141  
142  
143  
144  
145  
146  
147  
148  
149  
150  
151  
152  
153  
154  
155  
156  
157  
158  
159  
160  
161  
162  
163  
164  
165  
166  
167  
168  
169  
170  
171  
172  
173  
174  
175  
176  
177  
178  
179  
180  
181  
182  
183  
184  
185  
186  
187  
188  
189  
190  
191  
192  
193  
194  
195  
196  
197  
198  
199  
200  
201  
202  
203  
204  
205  
206  
207  
208  
209  
210  
211  
212  
213  
214  
215  
216  
217  
218  
219  
220  
221  
222  
223  
224  
225  
226  
227  
228  
229  
230  
231  
232  
233  
234  
235  
236  
237  
238  
239  
240  
241  
242  
243  
244  
245  
246  
247  
248  
249  
250  
251  
252  
253  
254  
255  
256  
257  
258  
259  
260  
261  
262  
263  
264  
265  
266  
267  
268  
269  
270  
271  
272  
273  
274  
275  
276  
277  
278  
279  
280  
281  
282  
283  
284  
285  
286  
287  
288  
289  
290  
291  
292  
293  
294  
295  
296  
297  
298  
299  
300  
301  
302  
303  
304  
305  
306  
307  
308  
309  
310  
311  
312  
313  
314  
315  
316  
317  
318  
319  
320  
321  
322  
323  
324  
325  
326  
327  
328  
329  
330  
331  
332  
333  
334  
335  
336  
337  
338  
339  
340  
341  
342  
343  
344  
345  
346  
347  
348  
349  
350  
351  
352  
353  
354  
355  
356  
357  
358  
359  
360  
361  
362  
363  
364  
365  
366  
367  
368  
369  
370  
371  
372  
373  
374  
375  
376  
377  
378  
379  
380  
381  
382  
383  
384  
385  
386  
387  
388  
389  
390  
391  
392  
393  
394  
395  
396  
397  
398  
399  
400  
401  
402  
403  
404  
405  
406  
407  
408  
409  
410  
411  
412  
413  
414  
415  
416  
417  
418  
419  
420  
421  
422  
423  
424  
425  
426  
427  
428  
429  
430  
431  
432  
433  
434  
435  
436  
437  
438  
439  
440  
441  
442  
443  
444  
445  
446  
447  
448  
449  
450  
451  
452  
453  
454  
455  
456  
457  
458  
459  
460  
461  
462  
463  
464  
465  
466  
467  
468  
469  
470  
471  
472  
473  
474  
475  
476  
477  
478  
479  
480  
481  
482  
483  
484  
485  
486  
487  
488  
489  
490  
491  
492  
493  
494  
495  
496  
497  
498  
499  
500  
501  
502  
503  
504  
505  
506  
507  
508  
509  
510  
511  
1
2
3
4
5
6
7
8
9
36 68 100  
37 69 101  
38 70 102  
39 71 103  
40 72 104  
41 73 105  
10 42 74 106  
11 43 75 107  
12 44 76 108  
13 45 77 109  
14 46 78 110  
15 47 79 111  
16 48 80 112  
17 49 81 113  
18 50 82 114  
19 51 83 115  
20 52 84 116  
21 53 85 117  
22 54 86 118  
23 55 87 119  
24 56 88 120  
25 57 89 121  
26 58 90 122  
27 59 91 123  
28 60 92 124  
29 61 93 125  
30 62 94 126  
31 63 95 127  
Dip Switch Position  
DMX Address  
LED-RAIN36 User Manual  
12  
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
WEIGHT & DIMENSIONS  
Length........................................................................................................................125 mm (4.92 in)  
Width..........................................................................................................................125 mm (4.92 in)  
Height ........................................................................................................................200 mm (7.87 in)  
Weight........................................................................................................................1.1Kgs (2.43 lbs)  
POWER  
Switch-selectable power setting ..................................................................115V 60 Hz or 230V 50 Hz  
AC input............................................................................................................... Power cord attached  
European version............................................................................................................... 240V 50 Hz  
FUSE  
Main............................................................................................................ 20mm Glass 1A Fast Blow  
CONTROL & PROGRAMMING  
Data input ............................................................................................. locking 3-pin XLR male socket  
Data output ........................................................................................ locking 3-pin XLR female socket  
Data pin configuration ............................................................................pin 1 shield, pin 2 (-), pin 3 (+)  
Protocols.....................................................................................................................DMX-512 USITT  
DMX Channels....................................................................................................................................2  
ORDERING INFORMATION  
LED-RAIN36. ................................................................................................................... LED-RAIN36  
Technical Support  
Address: Service Dept.  
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)  
Support (Email): [email protected]  
Telephone: (954) 929-1115 - (Press 4)  
Fax: (954) 929-5560 - (Attention: Service)  
LED-RAIN36 User Manual  
13  
2006-07-14/15:25  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Billy Goat Vacuum Cleaner HTR1601V User Manual
Black Decker Mixer MX40 User Manual
BMW Car Stereo System K1200 LT User Manual
Braun Thermometer 6013 User Manual
Briggs Stratton Air Cleaner 543200 User Manual
Bushnell Digital Camera 26 2440 User Manual
Cary Audio Design Car Amplifier CAD 300 SE User Manual
Casio Digital Camera EX TR15 User Manual
Celestron Hunting Equipment 52233 User Manual
Centro Gas Grill 07012009 User Manual