LED PAR 56-24UVB
User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
1. BEFORE OU BEGIN
Y
What is included
•
•
•
•
1 x LED PAR 56-24UVB
1 x Gel Holder
1 x Warranty Card
1 x User Manual
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure
that all parts are present, and have been received in good condition. Notify the shipper
immediately and retain packing material for inspection if any parts appear damaged from
shipping or the carton itself shows signs of mishandling. Save the carton and all packing
materials. In the event that a fixture must be returned to the factory, it is important that the fixture
be returned in the original factory box and packing.
Manual Conventions
CHAUVET® manuals use the following conventions to differentiate certain types of information
from the regular text.
MEANING
CONVENTION
[10]
<Menu>
1~512
50/60
A DIP switch to be configured
A key to be pressed on the fixture’s control panel
A range of values
A set of values of which only one can be chosen
A menu option not to be modified (for example, showing the operating
mode/current status)
Settings
MENU >
Settings
A sequence of menu options to be followed
A value to be entered or selected
ON
Icons
This manual uses the following icons to indicate information that requires special attention on the
part of the user.
MEANING
ICONS
This paragraph contains critical installation, configuration or operation
information. Failure to comply with this information may render the fixture
partially or completely inoperative, cause damage to the fixture or cause
harm to the user.
This paragraph contains important installation or configuration information.
Failure to comply with this information may prevent the fixture from
functioning correctly.
This paragraph reminds you of useful, although not critical, information.
1. Before You Begin
3
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Instructions
Please read these instructions carefully. It includes important information
about the installation, usage and maintenance of this product.
•
•
Please keep this User Manual for future consultation. If you sell the unit to another
user, be sure that they also receive this instruction booklet.
Always make sure that you are connecting to the proper voltage, and that the line
voltage you are connecting to is not higher than that stated on the decal or rear panel
of the fixture.
•
This product is intended for indoor use only! To prevent risk of fire or shock, do not
expose fixture to rain or moisture.
•
•
Make sure there are no flammable materials close to the unit while operating.
The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm)
from adjacent surfaces. Be sure that no ventilation slots are blocked.
•
Always disconnect from power source before servicing or replacing fuse and be sure to
replace with same fuse source.
•
•
Secure fixture to fastening device using a safety chain.
Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at
temperatures higher than this.
•
In the event of a serious operating problem, stop using the unit immediately. Never try
to repair the unit by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
center.
•
•
•
•
Never connect the device to a dimmer pack.
Make sure the power cord is never crimped or damaged.
Never disconnect the power cord by pulling or tugging on the cord.
Never carry the fixture directly from the cord. Always use the hanging/mounting
bracket.
•
Avoid direct eye exposure to the light source while it is on.
1. Before You Begin
4
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
2. INTRODUCTION
Product Overview
Control Panel
(LED display)
Microphone
Microphone Sensitivity
Adjustment Knob
Fuseholder
DMX Out
DMX In
Power Input
Bracket
Adjustment Knob
Attachment Bolt (not
meant to be adjusted)
Power Output
Hanging/mounting
(13 mm hole)
Gel Frame
Release
Gel Frame
Power Output
Bracket
Adjustment Knob
2. Introduction
5
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
3. SETUP
AC Power
This fixture runs on 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure the line
voltage to which you are connecting it is within the range of accepted voltages.
To determine the power requirements for a particular fixture, see the label affixed to the back
plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating
indicates its average current draw under normal conditions.
Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat
(variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only
as a 0 to 100% switch.
Always connect the fixture to a circuit with a suitable electrical ground.
PoLinking
This fixture contains power linking via the Edison outlet located in front of the power input cable.
Please see the diagram below for further explanation.
The maximum quantity of LED PAR 56-24UVB that may be linked is 18.
Fixture 1
Fixture 2
Fixture 3
Additional power
link out
The power linking shown in this document is for the Chauvet® North American version
ONLY! Therefore, it is the customer’s responsibility to check with the Dealer/Distributor
regarding power linking on the local version of the product. Connections and availability
may change, depending on the power requirements and/or regulations of each
country/region.
3. Setup
6
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting
Orientation
The LED PAR 56-24UVBmay be mounted in any position provided there is adequate room for
ventilation.
Rigging
Be sure that the structure can support the weight of the fixture. Please see the “Technical
Specifications” section of this manual for a detailed weight listing. Mount the fixture securely. Use
a screw, nut and bolt, or a hanging clamp. The hole in each bracket is 13 mm in size. When
rigging, consider routine maintenance and control panel access. Please see the following notes
on installation.
•
Be sure to orient the gel frame release so that it is pointing up. Please see the diagram
below for a visual reference.
•
•
If you intend to use the power link out with multiple fixtures, consider the length of each
power cable, and mount the fixtures close enough to one another to account for this.
When aiming the fixtures, you may use the bracket adjustment knob. Loosen the knob,
adjust to the desired angle, and then tighten the knob by turning clockwise. Do not use
tools for this step, as it may cause damage.
•
•
Use the secondary bracket for floor standing applications.
Always use safety cables.
Mounting
Bracket
Secondary bracket
(used primarily for
standing position)
Do not use a tool on
the bracket
adjustment knob
Aim the fixture with the
gel frame release
pointing up, (as shown
in this diagram)
3. Setup
7
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
4. OPERATING INSTRUCTIONS
Configuring the Starting Address
The LED PAR 56-24UVBfixture uses two DMX channels. The highest channel that the fixture may
be set to in order to function properly is 511. Any address higher than this will prevent access to all
of the channels.
If this is your first time using DMX, we recommend reading the “DMX Primer” section in the
“Appendix”.
Control Panel Functions
Access control panel functions using the four buttons located directly underneath the LED display
on the included wired remote.
BUTTON
FUNCTION
Used to scroll through the
current operating mode,
as well as back out of the
current menu option
<MENU>
Used to select increasing
advancement in the value
<UP>
Used to select decreasing
advancement in the value
<DOWN>
<ENTER>
Used to select a value
and store it to memory
MENU
UP DOWN ENTER
Menu Map
MAIN FUNCTION
SUB-FUNCTION
SELECTION
SUB-SELECTION
DESCRIPTION
Select for DMX mode
and the starting
address
DMX Mode
512
d001~d512
The speed is
Auto Mode
AUtO
SND
adjustable using S--
This is the sound-
active mode. Use the
microphone sensitivity
adjust knob along
with this mode
Sound-Active
Mode
Select the intensity for
the static dimmer
Select the speed
range for the auto
program (slow to fast)
Static Dimmer
U--
S--
u 1~100
(default range
is S050)
-
S001~S100
4. Operating Instructions
8
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
DMX Operation
This operating mode allows control of the fixture with an external DMX controller. You must set the
starting address for this mode. If this is your first time using DMX, then it is recommended that you
refer to the “DMX Primer” section in the “Appendix” of this manual.
1. Press <MENU> until 512 appears on the LED screen.
2. Press <ENTER>.
3. Using <UP> and <DOWN>, select the desired DMX address (d001~d512).
4. Press <ENTER>.
All fixtures must be individually set to DMX using the instructions above.
Master/Slave Mode (Sound-Active, Auto Mode)
This mode allows a single unit to run to the beat of the music, or the unit will change automatically.
DMX cables must be used to daisy chain between the fixtures from the output of the master unit.
Master:
1. Set the master unit to run in either Automatic mode or Sound-Active mode. Please
see the appropriate sections on this user manual for instructions on this process.
Slave:
1. Press <MENU> until 512 appears on the LED screen.
2. Press <ENTER>.
3. Using <UP> and <DOWN>, set the starting address to d001.
4. Press <ENTER>.
All fixtures must be individually set to either master or slave mode using the instructions
above.
Only one fixture may be set to master. Having two or more fixtures in the same daisy chain
will prevent the fixtures from working properly.
Do not connect a DMX controller for this setup.
4. Operating Instructions
9
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Automatic
This fixture has a preprogrammed pulsating chase with adjustable speed. Access this via the
control panel of the front of the fixture. Please see the instructions below for further details.
1. Press <MENU> until S-- appears on the LED screen.
2. Using <UP> and <DOWN>, select the desired speed (S 1~100).
3. Press <ENTER>.
4. Press <MENU> until AUtO appears on the LED screen.
5. Press <ENTER>.
Sound-Active
This fixture has a preprogrammed sound triggered chase. Access this via the control panel on the
front of the fixture, and the speed may be adjusted using the audio adjustment knob. Please see
the chart below for further explanation.
1. Press <MENU> until SNd appears on the LED screen.
2. Press <ENTER>.
3. Use the microphone sensitivity adjustment knob to adjust the microphone sensitivity.
Static Dimmer
This fixture has a variable static dimmer mode. Access this via the control panel on the back of
the fixture. Please see the chart below for further explanation.
1. Press <MENU> until U-- appears on the LED screen.
2. Using <UP> and <DOWN>, select the desired intensity (u0~100).
3. Press <ENTER>.
DMX Channel Values
CHANNEL
VALUE
FUNCTION
Dimmer
0%~100%
1
2
000 Ù 255
Strobe
No Function
Strobe: 0%~100%
000 Ù 015
016 Ù 255
4. Operating Instructions
10
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
5. APPENDIX
General Troubleshooting
SYMPTOM
POSSIBLE CAUSE(S
)
POSSIBLE ACTION(S)
• Check total load placed on the
electrical circuit.
• Excessive circuit load
Breaker/Fuse
keeps blowing
• Short circuit along the power
wires
• Check for a short in the electrical
wiring (internal and/or external).
• No power
• Loose power cord
• Check for power on Mains.
• Check power cord
Device does not
power up
• Check Control Panel and unit
addressing
• Wrong DMX addressing
• Damaged DMX cables
• Wrong polarity settings on the
controller
• Check DMX cables
• Check polarity switch settings on
the controller
Fixture is not
responding to DMX
• Loose DMX cables
• Faulty DMX interface
• Faulty Main PCB
• Check cable connections
• Replace DMX input
• Replace Main PCB
• Non DMX cables
• Bouncing signals
• Use only DMX compatible cables
• Install terminator as suggested.
• Install amplifier right after fixture
with strong signal.
• Install an optically coupled DMX
splitter after unit #32.
• Long cable / Low level signal
• Too many fixtures
Loss of signal
• Keep DMX cables separated from
power cables or black lights.
• Interference from AC wires
If you still have a problem after trying the above solutions, please contact CHAUVET®
Technical Support.
5. Appendix
11
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
DMX Primer
There are 512 channels in a DMX connection. A fixture capable of receiving DMX will require one
or a number of sequential channels. The user must assign a starting address on the fixture that
indicates the first channel reserved in the controller. There are many different types of DMX
controllable fixtures and they all may vary in the total number of channels required. Choosing a
start address should be planned in advance. Channels should never overlap. If they do, this will
result in erratic operation of the fixtures whose starting address is set incorrectly. You can
however, control multiple fixtures of the same type using the same starting address as long as the
intended result is that of unison movement or operation. In other words, the fixtures will all
respond exactly the same.
DMX fixtures are designed to receive data through a daisy chain. A daisy chain connection is
where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in
which the fixtures are connected is not important and has no effect on how a controller
communicates to each fixture. Use an order that provides for the easiest and most direct cabling.
Connect fixtures using shielded two conductor twisted pair DMX data cable with three pin XLR
male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and
pin 3 is Data positive (S+).
Fixture Linking (Daisy Chain)
You will need a daisy chain to run light shows of one or more fixtures using a DMX controller or to
run synchronized shows on two or more fixtures set to a master/slave operating mode. The
combined number of channels required by all the fixtures on a daisy chain determines the number
of fixtures the data link can support.
To comply with the EIA-485 standard, do not connect more than 32 fixtures on one daisy
chain. Connecting more than 32 fixtures on one daisy chain without the use of a DMX
optically-isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended cable distance: 500 m (1640 ft)
Maximum recommended number of fixtures on a daisy chain: 32
Data Cabling
To link fixtures together you must obtain data cables. You can purchase CHAUVET® certified
DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create
your own cable please use data-grade cables that can carry a high quality signal and are less
prone to electromagnetic interference.
DMX Data Cable
Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485
applications. Standard microphone cables cannot transmit DMX data reliably over long distances.
The cable must have the following characteristics:
Type:
shielded, 2-conductor twisted pair
30 pF/ft
Maximum capacitance between conductors:
Maximum capacitance between conductor and shield:
Maximum resistance:
Nominal impedance:
55 pF/ft
20 ohms/1000 ft
100 ~ 140 ohms
5. Appendix
12
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
Cable Connectors
Cabling must have a male XLR connector on one end and a female XLR
connector on the other end.
DMX connector configuration
COMMON
DMX +
1
3
1
3
INPUT
OUTPUT
2
2
DMX
-
Terminator
To avoid signal transmission problems
and interference, it is always advisable to
connect a DMX signal terminator.
1
3
2
120 ohm ¼ W resistor
between pin 2 (DMX -) and
pin 3 (DMX +) on the
output of the last fixture
Do not allow contact between the common and the fixture’s chassis ground. Grounding
the common can cause a ground loop, and your fixture may perform erratically. Test
cables with an ohm meter to verify correct polarity and to make sure the pins are not
grounded or shorted to the shield or each other.
Setting the Starting Address
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a
start address from 1~512. A fixture requiring one or more channels for control begins to read the
data on the channel indicated by the start address. For example, a fixture that uses six DMX
channels and was addressed to start on DMX channel 100, would read data from channels: 100,
101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap,
and note the start address selected for future reference.
If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping
to the “Appendix” section and reading the heading “DMX Primer”. It contains very useful
information that will help you understand its use.
5. Appendix
13
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Pin to 5-Pin Conversion Chart
If you use a controller with a 5-pin DMX output connector, you will need to use a 5-pin to
3-pin adapter. The chart below details a proper cable conversion:
3-PIN TO 5-PIN CONVERSION CHART
Conductor
3-Pin Female (Output)
Pin 1
5-Pin Male (Input)
Pin 1
Ground/Shield
Data ( - ) signal
Data ( + ) signal
Not used
Pin 2
Pin 3
Pin 2
Pin 3
Pin 4
Pin 5
Not used
Setting up a DMX Daisy Chain
1. Connect the (male) 3-pin connector side of
the DMX cable to the output (female) 3-pin
connector of the controller.
Universal DMX Controller
2. Connect the end of the cable coming from the
controller which will have a (female) 3-pin
connector to the input connector of the next
fixture consisting of a (male) 3-pin connector.
This drawing
3. Then, proceed to connect from the output as
stated above to the input of the following
fixture and so on.
provides a general
illustration of the
DMX input/output
panel of a lighting
fixture.
Continue the link
5. Appendix
14
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
General Maintenance
To maintain optimum performance and minimize wear, fixtures should be cleaned frequently.
Usage and environment are contributing factors in determining frequency. As a general rule,
fixtures should be cleaned at least twice a month. Dust build up reduces light output performance
and can cause overheating. This can lead to reduced lamp life and increased mechanical wear.
Be sure to power off fixture before conducting maintenance.
•
•
Unplug fixture from power.
Use a vacuum or air compressor and a soft brush to remove dust collected on external
vents.
•
Clean all lenses when the fixture is cool with a mild solution of glass cleaner or
Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue.
•
•
Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens.
Gently polish optical surfaces until they are free of haze and lint.
The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize
light output. Cleaning frequency depends on the environment in which the fixture operates.
Damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the
unit’s optics. Clean with soft cloth using normal glass cleaning fluid. Clean the external optics at
least every 20 days. Clean the fixture at least every 30/60 days.
Always dry the parts carefully after cleaning them.
Never spin a fan using compressed air.
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing; call tags will not be
issued. Package must be clearly labeled with a Return Merchandize Authorization Number (RMA
#). Products returned without the RMA # will be refused. Call CHAUVET® and request an RMA #
prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief
description of the cause for the return. Be sure to pack fixture properly; any shipping damage
resulting from inadequate packaging is the customer’s responsibility. As a suggestion, proper
UPS packing or double-boxing is always a safe method to use. CHAUVET® reserves the right to
use its own discretion to repair or replace product(s).
If you are given an RMA #, please include the following information on a piece of paper
inside the box:
1)
2)
3)
4)
5)
Your name
Your address
Your phone number
The RMA #
A brief description of the symptoms
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore, the damage must be
reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify
and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any
other claim for items such as missing component/part, damage not related to shipping, and
concealed damage, must be made within seven (7) days of receiving merchandise.
5. Appendix
15
9/13/2010 2:33 PM
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL SPECIFICATIONS
WEIGHT & DIMENSIONS
Length.............................................................................................................9.2 in (234 mm)
Width...............................................................................................................9.5 in (241 mm)
Height............................................................................................................16.3 in (415 mm)
Weight.............................................................................................................. 5.4 lbs (2.4 kg)
POWER
Auto-ranging Power Supply.............................................................. 100~240 VAC, 50/60 Hz
Power Consumption @ 120 V ................................................35 W (0.5 A) max, 0.5 A inrush
Power Consumption @ 230 V ................................................31 W (0.5 A) max, 0.5 A inrush
Power output........................................................................................................18 units max
LIGHT SOURCE
LED.................................................................................................... 24 1 W (UV) 50,000 hrs
PHOTO OPTIC
Coverage angle...................................................................................................................23°
INDOOR/OUTDOOR
Rating........................................................................................................ For indoor use only
THERMAL
Maximum ambient temperature........................................................................104° F (40° C)
ORDERING INFORMATION
LED PAR 56-24UVB.................................................................................. LEDPAR5624UVB
WARRANTY INFORMATION
Warranty ..............................................................................................2-year limited warranty
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTACT US
World Wide
General Information
CHAUVET®
5200 NW 108th Ave
Sunrise, FL 33351
voice: 954.929.1115
fax:
954.929.5560
toll free: 800.762.1084
Technical Support
World Wide Web
CHAUVET®
5200 NW 108th Ave
Sunrise, FL 33351
voice: 954.929.1115 (Press 4)
fax:
954.929.5560 (Attention: Service)
Download from Www.Somanuals.com. All Manuals Search And Download.
|