1.888.227.2178
Table of Contents
To register your fan, please visit:
What to Expect with
Your Installation
Tools Needed
Mounting Options
Ceiling Bracket
Save your receipt for proof of purchase.
Congratulations on purchasing your new Casablanca®
ceiling fan! It will provide comfort and performance in
your home or office for many years. This installation and
operation manual contains complete instructions for
installing and operating your fan.
30 inches
4
2
3
5
We are proud of our work and
appreciate the opportunity
to supply you with the best
Preparation
Downrod
Wiring
Wall Control
Canopy
ceiling fan available anywhere
in the world.
6
7
11
17
12
13
Maintenance
& Cleaning
Blades
Switch Housing
Operation
Troubleshooting
?
?
?
?
?
14
15
18
19
1
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Tools Needed
Pliers
Wire Strippers
Screwdrivers
Ladder
9/64” Drill Bit
(optional)
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
O
34
CEILING
Mounting Options
If you have a flat ceiling:
Hang your fan by a standard downrod (included).
Standard
Mounting
Support
Structure
Support
Structure
If you have an angled ceiling:
Ceiling
Outlet Box
(required)
1. You will need a longer downrod (sold separately).
Angled
Mounting
2. If your ceiling angle is greater than 34°, you will
also need an Angled Mounting Kit (sold separately).
Ceiling
Angled
(required)
Standard
Mounting
Style
Outlet Box
Mounting
Style
Use the three steps below to determine if your ceiling angle is greater than 34°
1
2
3
34°
PLACE
SLIDE
toward ceiling
FOLD
against wall
on dotted line
Guide Touches
BOTH Ceiling & Wall
Guide Touches
but NOT Ceiling
Wall
Use Standard Mounting
or Low-Profile Mounting
Use Angled Mounting
to hang the fan from a
to hang the fan from a flat ceiling.
vaulted or angled ceiling.
You need BOTH
a Longer
You need ONLY
a Longer
Downrod &
an Angled
Downrod
Mounting Kit
*most common
4
Download from Www.Somanuals.com. All Manuals Search And Download.
1.888.227.2178
Ceiling Bracket
OFF
For angled ceilings, point
opening toward peak.
Use wood screws
Use machine screws
(included) when securing
to support structure with
(provided with outlet
box) when securing to
approved electrical outlet existing ceiling fan-rated
box. Drill 9/64” pilot holes
outlet box. Make sure
in support structure to aid
it is securely installed
in securing ceiling bracket and is acceptable for fan
with hardware found in support of 31.8 kg (70 lbs)
the
hardware bag.
or less.
Make sure all four bumpers are
If you are unable to do this,
call Technical Support at
1-888-277-2178.
still attached.
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
Refer to warning w.1 on pg. 2
5
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Preparation
Time Saver Tip: Get a helper
to insert grommets, found in
the
hardware bag, into the
Remove the shipping blocks from the
motor. Save the screws. They will be
needed for blade iron installation.
blades while you’re doing the
next couple of steps.
Note: Some fans will have a shipping
ring instead of shipping blocks. Please
remove the ring and save the screws.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Downrod
Standard
skip to next page
Downrod
for ceilings 8-10’ high
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Longer
Downrod
for angled
ceilings or
ceilings 10’ or
higher
1
2
3
4
5
Shorter
Downrod
for fans installed
close to ceiling
10
9
8
7
6
Steps 6-10 to reassemble with new pipe
7
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Downrod (continued)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
The wires can be cut, but
leave at least 8” extending
from the top of the downrod.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
8”
3/8”
If the setscrew is not tightened
securely, the fan may fall.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Downrod (continued)
Put the wires and downrod through the canopy.
Let the canopy sit loosely on top of the fan.
DO NOT PICK THE FAN UP BY THE
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Wiring
Note: To connect the wires, hold
the bare metal leads together and
place a wire connector over them,
then twist clockwise until tight.
C
Receiver
Using an orange wire connector
from the hardware bag:
Connect the 3 grounding wires
(green, green/yellow stripe, or bare
copper) coming from the ceiling,
downrod, and ceiling bracket.
green/yellow stripe
Place the receiver on top of the downrod
assembly as shown.
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
10
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Wiring (continued)
Using an orange wire connector from
Using the wire connectors from the
remote control hardware bag:
the
hardware bag:
•
Connect the black wire
•
•
•
Connect the white wire from the
receiver (marked “common out”)
to the white wire from fan.
(ungrounded) from the ceiling to
the black wire from the receiver
(marked “live in”).
Connect the black wire from the
receiver (marked “fan out”) to
the black wire from the fan.
•
Connect the white wire (grounded)
from the ceiling to the white wire
from the receiver (marked “neutral
in” or “common in”).
Connect the blue wire from the
receiver (marked ”light out”) to
the blue wire from the fan.
The red wire from the receiver will
not be used, it has a pre-installed
wire terminator.
M
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
11
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Wall Control
Screw
Cut-Out
Drywall
Drill Holes
Before
Drywall
Anchors
Painter’s
Tape
Cover Plate
Template
Template
Template
After
1. Tape the provided wall control
template with painter’s tape at
the desired installation area.
2. Drill holes inside the four
corners of the template.
Note: Make sure the wall
control template is level before
proceeding to the next step.
1. Using a 9/64 drill bit, drill a hole
in each screw cut-out on the wall
control template.
2. Using a hammer, tap a drywall
anchor found in the wall control
hardware bag into each hole
until the drywall anchor is flush
with the wall.
1. Using a drywall punch saw,
cut out the interior shape of
the template using one of
the four drilled corners as a
starting point.
2. Remove the template and the
cut-out section of drywall.
1. Insert the wall control into the
dry wall cut out.
2. Align the screw holes in the wall
control with the drywall anchors.
3. Install the cover plate using
a Phillips Head screwdriver
to secure the two cover plate
screws found in the wall control
hardware bag through the wall
control and into the drywall
anchors.
If you are using a outlet box for wall control installation, the wires coming from the wall
control must be grounded using the attached green wire. If not placed in an outlet box, cap
the green wire coming from the wall control with an included wire nut.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Canopy
Screw
Holes
Position the canopy so that, when
lifted into place, the canopy fits into
the hanging bracket as shown.
Lift the canopy into place so that
the screw holes are aligned.
Insert the two canopy screws
found in the
hardware bag.
Note: Fan style may vary.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Blades
Remember the screws that
you kept after removing the
shipping blocks (page 6)? You
need them plus five more from
the hardware bag for this step.
Lightly attach the blade irons to the
Insert grommets found in the
hardware
motor with screws found in
bag into the holes in the blades, then
secure each blade to a blade iron with
the
hardware bag, then securely
tighten after both screws are attached.
screws found in the
hardware bag.
Your blades are shielded with Dust Armor® which
is a nanotechnology coating that repels dust. For
cleaning the fan, use soft brushes or cloths to prevent
scratching. Cleaning agents may damage the finishes.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Switch Housing
Feed the wire plug through the center
hole of the upper switch housing, then
wrap keyhole slots around the screws and
twist counterclockwise.
Insert the third screw, found in
Screw two housing assembly screws
from the hardware bag halfway into
the motor housing. It does not matter
which two screw holes you choose.
the
hardware bag, into place and
then tighten all three screws.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing fixture falling.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
Switch Housing (continued)
Lift the lower switch housing up until the
holes line up with the screw holes in the
upper switch housing. Install the three
switch housing screws, found in
Connect the plugs from the upper and
lower switch housings. Make sure to
line up the colored markings on the
connectors.
the
hardware bag.
Make sure the lower switch housing is securely attached to the
upper switch housing. Failure to properly secure all 3 assembly
screws could result in the switch housing fixture falling.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Operation
(Low)
Fan
Fan
Speed
Speed
(High)
Battery
Lights
Up
ON
Lights
Down
Battery
Holder
Fan
Power
Reverse
Battery
Door
Battery
Holder
Before operating the wall control,
press on the battery door to eject it.
Unscrew the battery holder. Insert the
battery, found in the control hardware
bag, with the positive (+) side facing
downward. Reinstall the battery
holder and reinsert the battery door
into the wall control.
The remote transmitter should already be
paired to the receiver and ready to use.
Quickly press the up or down arrow
to turn the lights off and on. Hold
the up or down arrow to dim or
raise the light level. The reverse
button changes the direction that
the blades turn. The power button
turns the fan off and on.
Note: If your need to pair your remote, turn
fan power off and back on at the circuit
breaker. Within three minutes, press and
hold both the Fan Off button and the 4
button for four seconds to pair the remote.
To prevent faulty operation, please
disconnect power from all other ceiling
fans within range while pairing.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Maintenance & Cleaning
Reverse
Button
(a)
Battery
(b)
Battery
Door
For cleaning the fan, use soft
brushes or cloths to prevent
scratching. Cleaning products
may damage the finishes.
The reverse button on the wall
control changes the air flow
direction. In warm weather, use
(a) downward air flow pattern.
In cold weather, use (b) upward
air flow pattern.
To change the battery, push on
the battery door to eject it. Remove
the battery using a small Phillip’s
head screwdriver. Replace with
same type battery, making sure
the (+) side is facing down. Replace
battery holder and battery door.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
1.888.227.2178
Troubleshooting
Fan doesn’t work
Noisy Operation
Remote doesn’t work
Excessive wobbling
• Press a fan speed button (1-4).
• Tighten the blade and blade
iron screws until they are snug.
• Install a fresh battery in the wall
control.
• Tighten all of the blade and
blade iron screws until they
are snug.
• Check the circuit breaker to
ensure the power is turned on.
• Check to see if any of the
blades are cracked. If so, replace
all of the blades.
• Make sure you have paired the
remote.
• Turn the power off, support
the fan carefully, and check
that the hanger ball is
properly seated.
• Check the wall control battery.
• Make sure that you have paired
the wall control.
• Use the provided balancing
kit and instructions to balance
the fan.
• Make sure the blades spin freely.
• Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on pages 10-11.
If you have multiple remotes or
multiple remote-controlled fans
installed on the same circuit
breaker and you are experiencing
interference or faulty operation of
your remote controls, please go to
and click “How do I properly install
multiple remote-controlled fans?” for
information on how to correct this
issue.
• Check the plug connection in
the switch housing.
AUTHORIZED SERVICE CENTERS
For the most updated listing of Casablanca Authorized
call toll free 1-888-227-2178.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
M6005-01 • 10/30/14 • © Casablanca Fan Company
|