Carrier Ventilation Hood 62MB User Manual

62MB,MC,MD,ME040-950  
Energy Recovery  
Ventilators  
Installation, Start-Up and  
Service Instructions  
Untrained personnel can perform the basic maintenance  
CONTENTS  
functions of cleaning coils and filters and replacing filters. All  
other operations should be performed by trained service  
personnel. When working on air-conditioning equipment,  
observe precautions in the literature, tags and labels attached to  
the unit, and other safety precautions that may apply.  
Page  
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . 1  
INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-58  
Step 1 — Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
Step 2 — Install Roof Curb . . . . . . . . . . . . . . . . . . . . . . . . 1  
• STAND-ALONE APPLICATIONS  
Follow all safety codes. Wear safety glasses and work  
gloves. These instructions describe how to install, start up, and  
service 62M energy recovery ventilator units.  
• COUPLED APPLICATIONS  
Step 3 — Rigging and Handling . . . . . . . . . . . . . . . . . 45  
• MOUNTING THE UNIT INDOORS  
Step 4 — Installing ERV Transitions. . . . . . . . . . . . . . . 47  
• ERV UNIT COUPLED WITH A 3 TO 12 1/2 TON  
HVAC UNIT  
Electrical shock can cause personal injury and death. Shut  
off all power to this equipment during installation. There  
may be more than one disconnect switch. Tag all discon-  
nect locations to alert others not to restore power until work  
is completed.  
Step 5 — Make Electrical Connections . . . . . . . . . . . . 47  
• POWER SUPPLY  
• ELECTRICAL CONNECTIONS  
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59-75  
Unit Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
Internal Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
Rain Hoods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
Energy Recovery Wheel. . . . . . . . . . . . . . . . . . . . . . . . . 59  
• DRIVE BELT  
INTRODUCTION  
The 62M energy recovery ventilator (ERV) units recover  
energy from building exhaust air and pre-condition ventilation  
air. All ERV units are available in either vertical discharge  
(through the bottom) or horizontal discharge configuration.  
The 62MB and MC vertical discharge units are used when a  
stand-alone ERV unit is required.  
The 62MD and ME horizontal discharge unit can be used as  
a stand-alone unit, or can also be coupled with a Carrier rooftop  
unit.  
• AIR SEALS  
Blower Rotation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59  
Airflow Settings and Adjustments. . . . . . . . . . . . . . . 59  
• FACTORY SETTING  
• CURVE SELECTION  
• ADJUST THE ERV BLOWER SPEED  
• MEASURE MOTOR VOLTAGE, AMPERAGE  
AND FAN RPM  
INSTALLATION  
• BELT MAINTENANCE  
Variable Air Volume Option. . . . . . . . . . . . . . . . . . . . . . 74  
Operating Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74  
• OCCUPIED MODE  
Step 1 — Inspection — Inspect the unit; file a claim  
with the shipping company if the unit is damaged. Check the  
packing list to ensure that the correct items have been received  
and notify your Carrier representative of any discrepancy.  
• UNOCCUPIED MODE  
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75-78  
Step 2 — Install Roof Curb  
Removing Wheel Segments for Cleaning  
(62M170-950 Units). . . . . . . . . . . . . . . . . . . . . . . . . . . . 75  
Removing and Installing Non-Segmented  
STAND-ALONE APPLICATIONS — The ERV unit can be  
installed without being coupled with a Carrier rooftop unit. The  
ERV units can be installed in one of three stand-alone applica-  
tions: down discharge, horizontal discharge, or a combination  
of both down discharge and horizontal discharge.  
When installing a stand-alone ERV unit refer to Fig. 1-45  
and, complete the following:  
Locate the Roof Curb — Prior to locating the roof curb con-  
sider the structural support required for the rooftop system and,  
the duct drop location in relation to the joists. Allow sufficient  
space for service, clearance, and locations of vents or other  
sources of air.  
Wheel for Cleaning (62M040 Units). . . . . . . . . . . . 75  
Removing and Installing Non-Segmented  
Wheel for Cleaning (62M075,120 Units) . . . . . . . 76  
Installing Wheel Segments (62M170-950 Units). . . 76  
Wheel Drive Motor and Pulley Replacement. . . . . 77  
Belt Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77  
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78,79  
START UP CHECKLIST. . . . . . . . . . . . . . . . . . . . . . . .CL-1  
SAFETY CONSIDERATIONS  
Installation and servicing of air-conditioning equipment can  
be hazardous due to system pressure and electrical compo-  
nents. Only trained and qualified service personnel should  
install, repair, or service air-conditioning equipment.  
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.  
Catalog No. 536-220 Printed in U.S.A. Form 62M-1SI Pg 1 1-06 Replaces: New  
Book 1  
4
Tab 10a 12a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set the Roof Curb — Fit the roof curb assembly by measuring  
across the corners of the curb to ensure a square fit. Set the roof  
curb over the roof opening. Level the curb by placing shims  
under the bottom flange of the curb. Secure the curb in place by  
welding or fastening the curb to the roof.  
Refer to Fig. 2 and 3 to determine the duct size required.  
Provide field manufactured duct and place into the supply and  
return openings in the curb.  
Install Gaskets — The ERV roof curbs come with a gasketing  
package to provide a seal between the ERV unit and the top  
perimeter of the roof curb. Install the gasket around the top  
perimeter of the curb and around the supply and return  
opening. (Some stand-alone curbs will not have duct open-  
ings.) Gasket strips must fit tightly together, leaving no gaps for  
leakage.  
IMPORTANT: The ERV roof curb must be set in  
precisely the correct location relative to the rooftop  
roof curb for the transitions to connect properly. See  
Fig. 7-44 for location dimensions.  
IMPORTANT: Gasket installation is critical for water  
integrity. Improperly installed gaskets can result in air  
or water leaks, leading to poor unit performance.  
Install Ductwork — Ductwork will be installed in the roof  
curb for vertical, coupled applications. The duct will hang from  
the top of the curb.  
NOTE: Ductwork must be installed before the rooftop unit is  
set in place.  
NOTE: Ductwork must be installed before the ERV unit is set  
in place.  
Install Roofing Materials — Insulate and add a cant strip to  
the roof curb. Follow suggested and acceptable roofing proce-  
dures for applying roofing materials. The roofing material  
should extend up to the wood nailer and be secured under the  
counter flashing. Follow all local, national, and industry roof-  
ing standards. Refer to Fig. 5 for roofing recommendations.  
24.09  
SUPPLY  
1.00  
TYP. 4X  
10.81  
22.94  
RETURN  
14.00  
11.50  
3.00  
TYP. 4X  
11.00  
NOTES:  
1. All dimensions are in inches.  
2. Roof curb shipped unassembled.  
Fig. 2 — Roof Curb — 62M040 for Stand-Alone Applications  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Typical Insulated deck pans.  
(Insulation face up) *  
D
S/A  
E
F
C
R/A  
G
H
B
LEGEND  
R/A — Return Air  
S/A — Supply Air  
A
*IMPORTANT: Insulation on deck pans must face up.  
NOTE: Roof curb shipped unassembled.  
DIMENSIONS (in.)  
CURB  
PART NO.  
62M UNIT SIZE  
Duct Sizes  
A
B
C
D
E
F
G
H
Return  
13.75 x 14.38  
17 x 23.5  
Supply  
13.75 x 11  
17 x 19  
075,120  
170-285  
330-640  
750,950  
62M-A-CRB-14S  
62M-B-CRB-14S  
62M-C-CRB-14S  
62M-D-CRB-14S  
27  
30.5  
49.63 14  
60.34 14  
14  
14  
11.3  
19.5  
23.41  
42.13  
1
2
2
2
14.7  
24  
30  
1.5  
1.75  
45.5  
55.41  
86.25  
17.5  
24.84  
32.5  
24.5 x 29.5  
32 x 41.75  
24.5 x 23  
32 x 41.75  
95.7  
14  
42.13  
Fig. 3 — Roof Curb — 62M075-950 for Vertical Stand-Alone Applications  
C
ERV Curb  
B
D
A
LEGEND  
Energy Recovery Ventilator  
NOTE: Roof curb shipped unassembled.  
DIMENSIONS (in.)  
CURB  
62M UNIT SIZE  
PART NO.  
ERV  
A
27  
49.63  
60.34  
95.7  
B
30.5  
14  
C
14  
45.5  
D
1.5  
1.75  
1.75  
1.75  
075,120*  
170-285†  
330-640  
750,950  
62M-A-CRB-14S  
62M-B-CRB-14S  
62M-C-CRB-14M  
62M-D-CRB-14M  
14  
14  
55.41  
86.25  
*62M075,120 curb is shipped with deckpans insulation and duct supports which may  
be discarded.  
†62M170-285 curb is shipped with deck pans and insulation.  
Fig. 4 — Roof Curb — 62M075-950 for Horizontal Stand-Alone Applications  
or Units Coupled with Rooftop Units 15 Tons and Above  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ERV Curb  
C
Must be Watertight  
Locator pieces to connect  
ERV curb to rooftop unit curb  
B
D
A
E
LEGEND  
Energy Recovery Ventilator  
NOTE: Roof curb shipped unassembled.  
ERV  
DIMENSIONS (in.)  
CURB  
PART NO.  
62M UNIT SIZE  
A
B
C
D
E
075,120  
170-285  
62M-A-CRB-14MC  
62M-B-CRB-14MC  
30.5  
49.63  
14  
14  
27  
45.5  
1.5  
19.81  
1.75 37.81  
Fig. 5 — Roof Curb — 62M075-285 Units 3 to 121/2 Ton Rooftop Units  
GASKETING  
ROOF CURB  
NAIL*  
RIGID  
INSULATION*  
FLASHING*  
CANT STRIP*  
ROOF FELT*  
ROOF DECK*  
ROOF*  
*Field provided.  
Fig. 6 — Roofing Materials — Recommendation  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RooftopUnit  
Filteraccessdoor  
shippedwithRooftop  
Unit  
62M040Unit  
Outsideairhood  
withaluminum  
waterentrain-  
mentfilter.  
Includesbaro-  
metricintake  
damper.  
Evaporation  
Coil  
Exhaust  
hood  
Filter  
Filters  
AccessoryERV  
Equipmentsupport  
StandardRooftop  
Unitroofcurb  
EXH  
TRANSITION DETAIL  
Supply  
Blower  
Panelcovering  
returnchamber  
3to6TonRooftopUnit  
Outside  
airhood  
Filter  
ERV  
wheel  
AccessoryTransition  
ROOF CURB LOCATION DETAIL  
3”  
Accessdoorto  
adjustbalancing  
damper  
To62M040Unit  
Balancingdamper  
Supply  
A
A
Return  
35”  
673/8”  
ERV  
Unit  
Support  
Rooftop  
Unit  
Curb  
35"  
AccessoryERV  
Equipmentsupport  
Side View A-A  
RooftopCurb  
LEGEND  
37”  
ERV — Energy Recovery Ventilator  
Top View  
ROOFTOP UNIT MODEL  
48/50HJ,TJ,TM  
ROOFTOP SIZE  
TRANSITION P/N  
62M-AATR-HJ36-D  
ROOFTOP ECONOMIZER  
62MA-900---004  
ERV EQUIPMENT SUPPORT P/N  
62MA-900---001  
004-007  
Fig. 17 — 62MD,ME040 Coupled with Carrier 48/50HJ,TJ,TM004-007 Vertical Discharge Rooftop Unit  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RooftopUnit  
Filteraccessdoor  
shippedwithRooftop  
Unit  
62M040Unit  
Outsideairhood  
withaluminum  
waterentrain-  
mentfilter.  
Includesbaro-  
metricintake  
damper.  
Field-Supplied  
Duct  
Exhaust  
hood  
Filter  
AccessoryERV  
Equipmentsupport  
StandardRooftop  
Unitroofcurb  
EXH  
TRANSITION DETAIL  
Supply  
Blower  
Panelcovering  
returnchamber  
3to6TonRooftopUnit  
Outside  
airhood  
Filter  
ERV  
wheel  
AccessoryTransition  
ROOF CURB LOCATION DETAIL  
3”  
Accessdoorto  
adjust balancing  
damper  
To62M040Unit  
Balancingdamper  
Supply  
Return  
A
A
35”  
673/8”  
ERV  
Unit  
Support  
Rooftop  
Unit  
Curb  
35"  
AccessoryERV  
Equipmentsupport  
Side View A-A  
RooftopCurb  
LEGEND  
ERV — Energy Recovery Ventilator  
37”  
ROOFTOP UNIT MODEL  
48/50HJ,TJ,TM  
ROOFTOP SIZE  
TRANSITION P/N  
62M-AATR-HJ36-D  
ROOFTOP ECONOMIZER  
62MA-900---008  
ERV EQUIPMENT SUPPORT P/N  
004-007  
62MA-900---001  
Fig. 18 — 62MD,ME040 Coupled with Carrier 48/50HJ,TJ,TM004-007 Horizontal Discharge Rooftop Unit  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RooftopUnit  
AccessoryTransition  
(Includesfrontpanel)  
RooftopUnit  
Supply  
Return  
TRANSITION DETAIL  
AccessoryERV  
Equipmentsupport  
AccessoryTransition  
2Piecefront  
panelcovers  
returnchamber  
Filter  
ERV  
wheel  
Filter  
62M040Unit  
Exhaust  
hood  
Outsideairhood  
Top View  
ROOF CURB LOCATION DETAIL  
To62M040Unit  
Accessdoorto  
adjust balancing  
damper  
35”  
805/16”  
A
A
4411/16”  
Return  
Supply  
ERV  
Unit  
Support  
Rooftop  
Unit  
Curb  
35"  
43/8”  
RooftopCurb  
Side View A-A  
LEGEND  
ERV — Energy Recovery Ventilator  
AccessoryERV  
Equipmentsupport  
ROOFTOP UNIT MODEL  
48/50PG  
ROOFTOP SIZE  
TRANSITION P/N  
62M-AATR-HJ36-D  
ERV EQUIPMENT SUPPORT P/N  
03-07  
62MA-900---001  
Fig. 19 — 62MD,ME040 Coupled with Carrier 48/50PG03-07 Vertical Discharge Rooftop Unit  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RooftopUnit  
AccessoryTransition  
(Includesfrontpanel)  
RooftopUnit  
TRANSITION DETAIL  
AccessoryERV  
Equipmentsupport  
AccessoryTransition  
2Piecefront  
panelcovers  
returnchamber  
Filter  
ERV  
wheel  
Filter  
62M040Unit  
Exhaust  
hood  
Outsideairhood  
TopView  
ROOF CURB LOCATION DETAIL  
To62M040Unit  
Accessdoorto  
adjust balancing  
damper  
35”  
805/16”  
A
A
4411/16”  
ERV  
Unit  
Support  
Rooftop  
Unit  
Curb  
35"  
43/8”  
RooftopCurb  
Side View A-A  
LEGEND  
ERV — Energy Recovery Ventilator  
AccessoryERV  
Equipmentsupport  
ROOFTOP UNIT MODEL  
48/50PG  
ROOFTOP SIZE  
TRANSITION P/N  
62M-AATR-HJ36-D  
ERV EQUIPMENT SUPPORT P/N  
03-07  
62MA-900---001  
Fig. 20 — 62MD,ME040 Coupled with Carrier 48/50PG03-07 Horizontal Discharge Rooftop Unit  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ROOF CURB LAYOUT  
TOP VIEW  
673/8"  
A
Supply  
Standard roof curb for  
3 to 6 ton rooftop unit  
Air  
373/16"  
Return  
Air  
3"  
35  
"
343/8"  
36"  
62MA-900---001  
Equipment Support  
A
"A-A" SIDE VIEW  
Standard Roof curb  
for3 to 6 tonrooftop unit  
35  
"
62MA-900---001  
Equipment Support  
14"  
Roof  
10.4"  
Fig. 21 — 62MD,ME040 Coupled with Carrier 48/50HJ,TJ,TM004-007 Rooftop Unit  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter door shipped  
with Rooftop unit.  
62M ERV Unit  
Rainhoods for  
optional economizer  
Rooftop unit  
Unit curb  
Rooftop unit  
AccessoryTransition  
62M075,120 ERV Unit  
Locator  
pieces  
(included with  
ERV curb,  
ERV curb  
must be watertight)  
SUPPLY  
ROOF CURB LOCATION DETAIL  
B
Rooftop  
Unit curb  
Locator Pieces ( included with ERV Curb)  
Cover panel provided  
30.5”  
LEGEND  
Energy Recovery Ventilator  
A
ERV  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed economizer  
cannot be used. Use the 62M economizer instead.  
27”  
2 3/4"  
20"  
ERV curb  
DIMENSIONS (in.)  
ROOFTOP UNIT  
MODEL  
ROOFTOP  
ROOFTOP SIZE  
TRANSITION P/N  
ERV CURB P/N  
ECONOMIZER  
A
B
373/16  
50  
004-007  
008,009  
012,014  
62M-ATR-HJ36-D  
62M-ATR-HJ78-D  
62M-ATR-HJ1012-D  
62M-A-CRB-14MC  
62M-A-CRB-14MC  
62M-A-CRB-14MC  
62MA-900---004  
62MA-900---005  
62MA-900---006  
673/8  
781/4  
781/4  
48/50HJ,TF,TJ,TM  
50  
Fig. 22 — 62MD,ME075,120 Coupled with Carrier 48/50HJ,TF,TJ,TM004-014 Vertical Discharge Rooftop Unit  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter door shipped  
with Rooftop unit.  
62M ERV Unit  
Horizontal supply and  
return duct (field supplied)  
Rooftop unit  
Rooftop Unit  
Accessory Transition  
62M075,120  
ERV Unit  
Locator  
pieces  
(included with  
ERV curb,  
ERV curb  
must be watertight)  
Optional Horizontal  
Economizer  
ROOF CURB LOCATION DETAIL  
B
Rooftop  
Unit curb  
Locator Pieces ( included with ERV curb)  
Cover panel provided  
LEGEND  
Energy Recovery Ventilator  
30.5"  
A
ERV  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed economizer  
cannot be used. Use the 62M economizer instead.  
27"  
2 3/4"  
20"  
ERV curb  
DIMENSIONS (in.)  
ROOFTOP UNIT  
MODEL  
ROOFTOP  
ROOFTOP SIZE  
TRANSITION P/N  
ERV CURB P/N  
ECONOMIZER  
A
B
373/16  
50  
004-007  
008,009  
012,014  
62M-ATR-HJ36-H  
62M-ATR-HJ78-H  
62M-ATR-HJ1012-H  
62M-A-CRB-14MC  
62M-A-CRB-14MC  
62M-A-CRB-14MC  
62MA-900---008  
62MA-900---009  
62MA-900---010  
673/8  
781/4  
781/4  
48/50HJ,TF,TJ,TM  
50  
Fig. 23 — 62MD,ME075,120 Coupled with Carrier 48/50HJ,TF,TJ,TM004-014 Horizontal Discharge Rooftop Unit  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Rooftop Unit  
Accessory Transition  
(Includes frontpanel)  
62M ERV Unit  
Supply  
Return  
Accessory  
Transition  
Locator  
pieces  
(included with  
ERV curb,  
ERV Wheel  
ERV Curb  
must be watertight)  
62M075,120 ERV Unit  
LEGEND  
ERV  
Energy Recovery Ventilator  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed econo-  
mizer cannot be used.  
TOP VIEW  
ROOF CURB LOCATION DETAIL  
20"  
A
ERV Curb  
30 1/12"  
CurbDetail  
A
A
B
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
27"  
20"  
Return  
Supply  
2 3/4"  
SideViewA-A  
Rooftop Unit Curb  
Locator pieces  
(included with  
ERV Curb)  
DIMENSIONS (in.)  
ROOFTOP MODEL  
48/50PG  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
805/16  
923/4  
B
4411  
5315  
03-07  
08-14  
62M-ATR-PG26-D  
62M-ATR-PG712-D  
62M-A-CRB-14MC  
62M-A-CRB-14MC  
/
/
16  
16  
Fig. 24 — 62MD,ME075,120 Coupled with Carrier 48/50PG03-14 Vertical Discharge Rooftop Unit  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Rooftop Unit  
Accessory Transition  
(Includes front panel)  
62M Unit  
Accessory  
Transition  
Locator  
pieces  
(included with  
ERV curb,  
ERV Wheel  
ERV Curb  
must be watertight)  
62M075-120 ERV Unit  
LEGEND  
Energy Recovery Ventilator  
ERV  
NOTE: When using a 62M ERV unit coupled with  
a Carrier rooftop unit, the rooftop factory or field-  
installed economizer cannot be used.  
TOP VIEW  
ROOF CURB LOCATION DETAIL  
20"  
A
ERV Curb  
30 1/12"  
CurbDetail  
A
A
B
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
27"  
20"  
2 3/4"  
SideViewA-A  
Rooftop Unit Curb  
Locator pieces  
(included with  
ERV Curb)  
DIMENSIONS (in.)  
ROOFTOP MODEL  
48/50PG  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
805/16  
923/4  
B
4411  
5315  
03-07  
08-14  
62M-ATR-PG26-H  
62M-ATR-PG712-H  
62M-A-CRB-14MC  
62M-A-CRB-14MC  
/
/
16  
16  
Fig. 25 — 62MD,ME075,120 Coupled with Carrier 48/50PG03-14 Horizontal Discharge Rooftop Unit  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter door shipped with  
Rooftop unit  
62M ERV Unit  
Rainhoods for  
optional economizer  
Rooftop unit  
Rooftop curb  
Top View  
Rooftop  
Unit  
Locator Pieces  
(included with ERV curb,  
must be watertight)  
ERV Curb  
AccessoryTransition  
62M170-285 ERV Unit  
SUPPLY  
Rooftop  
Unit curb  
ROOF CURB LOCATION DETAIL  
B
Locator Pieces ( included with ERV curb)  
Cover panel provided  
ERV curb  
49 5/8"  
A
45 1/2"  
LEGEND  
2 3/4"  
ERV  
Energy Recovery Ventilator  
38"  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed economizer  
cannot be used. Use the 62M economizer instead.  
Top View  
DIMENSIONS (in.)  
ROOFTOP UNIT  
MODEL  
ROOFTOP  
ROOFTOP SIZE  
TRANSITION P/N  
ERV CURB P/N  
ECONOMIZER  
A
B
373/16  
50  
004-007  
008,009  
012,014  
62M-BTR-HJ36-D  
62M-BTR-HJ78-D  
62M-BTR-HJ1012-D  
62M-B-CRB-14MC  
62M-B-CRB-14MC  
62M-B-CRB-14MC  
62MA-900---004  
62MA-900---005  
62MA-900---006  
673/8  
781/4  
781/4  
48/50HJ,TF,TJ,TM  
50  
Fig. 26 — 62MD,ME170-285 Coupled with Carrier 48/50HJ,TF,TJ,TM004-014 Vertical Discharge Rooftop Unit  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter door shipped  
with Rooftop unit.  
Rooftop Unit  
62M ERV Unit  
Optional  
Horizontal  
Economizer  
Locator  
pieces  
Top View  
Rooftop  
Unit  
(included with  
ERV curb,  
must be watertight)  
Horizontal  
Return duct  
ERV Curb  
(field supplied)  
AccessoryTransition  
62M170-285 ERV Unit  
Rooftop  
Unit curb  
ROOF CURB LOCATION DETAIL  
B
Locator Pieces ( included with ERV Curb)  
Cover Panel provided  
ERV curb  
49 5/8"  
A
45 1/2"  
LEGEND  
ERV  
Energy Recovery Ventilator  
2 3/4"  
38"  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed economizer  
cannot be used. Use the 62M economizer instead.  
Top View  
DIMENSIONS (in.)  
ROOFTOP UNIT  
MODEL  
ROOFTOP  
ROOFTOP SIZE  
TRANSITION P/N  
ERV CURB P/N  
ECONOMIZER  
A
B
373/16  
50  
004-007  
008,009  
012,014  
62M-BTR-HJ36-H  
62M-BTR-HJ78-H  
62M-BTR-HJ1012-H  
62M-B-CRB-14MC  
62M-B-CRB-14MC  
62M-B-CRB-14MC  
62MA-900---008  
62MA-900---009  
62MA-900---010  
673/8  
781/4  
781/4  
48/50HJ,TF,TJ,TM  
50  
Fig. 27 — 62MD,ME170-285 Coupled with Carrier 48/50HJ,TF,TJ,TM004-014 Horizontal Discharge Rooftop Unit  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
AccessoryTransition  
62M ERV unit  
LEGEND  
ERV  
Energy Recovery Ventilator  
NOTES:  
1. The 62M ERV unit cannot be coupled with  
horizontal return 48/50TJ,TM016-028 and  
48/50HJ015,017 units.  
Unit curb  
2. The ERV unit can be used with a factory-  
installed economizer, if desired.  
ERV curb  
TOP VIEW  
SIDE VIEW  
15 to 25 Ton RooftopUnit  
Rooftop Unit  
62M170-285  
ERV Unit  
62M170-285  
ERV Unit  
Accessory  
Transition  
*Optional  
Economizer  
Transition  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
ERV Curb  
A
A
45 1/2"  
ERV  
Unit  
Curb  
74 1/4"  
Rooftop  
44 3/4"  
Unit  
Curb  
18 11/16"  
44 3/4"  
49 5/8"  
67 1/16"*  
SIDE VIEW A-A  
TOP VIEW  
*Length is 891/16for 48/50TM028 units.  
ROOFTOP UNIT  
ROOFTOP SIZE  
TRANSITION P/N  
ERV CURB P/N  
MODEL  
48/50TJ,TM  
48/50HJ  
016-028  
015,017  
62M-BTR-HJ1525-D  
62M-BTR-HJ1525-D  
62M-B-CRB-14S  
62M-B-CRB-14S  
Fig. 28 — 62MD,ME170-285 Coupled with Carrier 48/50TJ,TM016-028  
and 48/50HJ015,017 Vertical Discharge Rooftop Unit  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Rooftop Unit  
Accessory Transition  
(Includes front panel)  
62M ERV Unit  
Supply  
Return  
Accessory  
Transition  
Locator  
pieces  
(included with  
ERV curb,  
must be watertight)  
ERV Wheel  
ERV Curb  
62M170-285 ERV Unit  
LEGEND  
ERV  
Energy Recovery Ventilator  
NOTE: When using a 62M ERV unit coupled with a Carrier roof-  
top unit, the rooftop factory or field-installed economizer cannot  
be used.  
TOP VIEW  
ROOF CURB LOCATION DETAIL  
A
38 3/4"  
ERV Curb  
49 5/8"  
CurbDetail  
A
A
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
B
38 3/4"  
45 1/2"  
Return  
Supply  
SideViewA-A  
0"  
Rooftop Unit Curb  
Locator pieces  
(included with  
ERV Curb)  
DIMENSIONS (in.)  
ROOFTOP MODEL  
48/50PG  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
805/16  
923/4  
B
4411  
5315  
03-07  
08-14  
62M-BTR-PG26-D  
62M-BTR-PG712-D  
62M-A-CRB-14MC  
62M-A-CRB-14MC  
/
/
16  
16  
Fig. 29 — 62MD,ME170-285 Coupled with Carrier 48/50PG03-14 Vertical Discharge Rooftop Unit  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Rooftop Unit  
Accessory Transition  
(Includes frontpanel)  
62M ERV Unit  
Accessory Transition  
Locator  
pieces  
(included with  
ERV curb,  
ERV Wheel  
ERV Curb  
must be watertight)  
62M170-285 ERV Unit  
LEGEND  
Energy Recovery Ventilator  
ERV  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed economizer  
cannot be used.  
TOP VIEW  
ROOF CURB LOCATION DETAIL  
A
38 3/4"  
ERV Curb  
49 5/8"  
CurbDetail  
A
A
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
B
38 3/4"  
45 1/2"  
SideViewA-A  
0"  
Rooftop Unit Curb  
Locator pieces  
(included with  
ERV Curb)  
DIMENSIONS (in.)  
ROOFTOP MODEL  
48/50PG  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
805/16  
923/4  
B
4411  
5315  
03-07  
08-14  
62M-BTR-PG26-H  
62M-BTR-PG712-H  
62M-B-CRB-14MC  
62M-B-CRB-14MC  
/
/
16  
16  
Fig. 30 — 62MD,ME170-285 Coupled with Carrier 48/50PG03-14 Horizontal Discharge Rooftop Unit  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Outside Air Hood (See Note 2)  
62M ERV Unit  
Rooftop Unit  
Curb  
Horizontal /Return Duct  
(field supplied)  
Accessory  
Transition  
Rooftop Unit  
Accessory  
Transition  
ERV Curb  
62M170-285 ERV Unit  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
O/A Hood  
NOTES:  
1. The ERV unit can be used with a factory-  
installed economizer, if desired.  
2. Transition includes a new outside air hood,  
which allows air intake through the front of the  
hood rather than the bottom. The new hood will  
use the filters from the original rooftop unit  
hood.  
Relief Hood  
Top View  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
44 3/4”  
ERV Curb  
A
49 5/8”  
CurbDetail  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
A
A
44 3/4"  
B
45 1/2”  
SideViewA-A  
Top View  
DIMENSIONS (in.)  
ROOFTOP MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
B
48/50PG  
48/50HJ  
20-28  
62M-BTR-HG1525-H  
62M-BTR-HG1525-H  
62M-B-CRB-14MC  
62M-B-CRB-14MC  
114.4  
114.4  
78.6  
78.6  
020-028  
Fig. 31 — 62MD,ME170-285 Coupled with Carrier 48/50PG20-28  
and 48/50HJ020-028 Horizontal Discharge Rooftop Unit  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Outside Air Hood (See  
Note 2)  
62M ERV Unit  
Standard HVAC Unit  
Roofcurb  
Accessory  
Transition  
Rooftop Unit  
ERV Curb  
Accessory  
Transition  
62M170-285 ERV Unit  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
NOTES:  
1. The ERV unit can be used with a factory-  
installed economizer, if desired.  
2. Transition includes a new outside air hood,  
which allows air intake through the front of  
the hood rather than the bottom. The new  
hood will use the filters from the original  
rooftop unit hood.  
O/A Hood  
Top View  
Relief Hood  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
44 3/4”  
A
49 5/8”  
CurbDetail  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
A
A
44 3/4"  
45 1/2”  
B
SideViewA-A  
ERV Curb  
Top View  
DIMENSIONS (in.)  
ROOFTOP MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
B
48/50PG  
48/50HJ  
20-28  
62M-BTR-HG1525-D  
62M-BTR-HG1525-D  
62M-B-CRB-14MC  
62M-B-CRB-14MC  
114.4  
114.4  
78.6  
78.6  
020-028  
Fig. 32 — 62MD,ME170-285 Coupled with Carrier 48/50PG20-28  
and 48/50HJ020-028 Vertical Discharge Rooftop Unit  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter access door  
shippedwith  
transition  
62M ERV Unit  
Rooftop Unit  
Outside air hood  
for optional  
economizer  
Accessory  
Transition  
Top View  
Rooftop Unit  
ERV Curb  
Accessory  
Transition  
62M330-640 ERV Unit  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
NOTE: When using a 62M ERV unit coupled with a  
Carrier rooftop unit, the rooftop factory or field-  
installed economizer cannot be used. Use the 62M  
economizer instead.  
Supply  
O/Ahood  
Outside air hood  
for optional  
economizer  
Exhaust hood  
ROOF CURB LOCATION DETAIL  
Rooftop Unit curb  
ERV curb  
781/4"  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
331/2"  
A
A
5513/32"  
Supply  
Side View A-A  
9"  
50"  
6011/32"  
331/2"  
Top View  
ROOFTOP UNIT MODEL ROOFTOP SIZE  
48/50HJ,TF,TJ,TM 012,014  
TRANSITION P/N  
62M-CTR-HJ1012-D  
ERV CURB P/N  
62M-C-CRB-14M  
ROOFTOP ECONOMIZER  
62MA-900---006  
Fig. 33 — 62MD,ME330-640 Coupled with Carrier 48/50HJ,TF,TJ,TM012,014 Vertical Discharge Rooftop Unit  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filter access door  
shippedwith  
transition  
Rooftop Unit  
62MERVUnit  
LEGEND  
Horizontal  
ERV  
O/A  
R/A  
S/A  
Energy Recovery Ventilator  
Outdoor Air  
supply duct  
Return Air  
(field supplied)  
Supply Air  
NOTE: When using a 62M ERV unit cou-  
pled with a Carrier rooftop unit, the rooftop  
factory or field-installed economizer cannot  
be used. Use the 62M economizer instead.  
Horizontal  
return(field  
supplied)  
Accessory  
Transition  
ERV Curb  
Top View  
Rooftop Unit  
Top View  
with Economizer  
Accessory  
Transitions  
62M330-640  
ERV Unit  
Accessory  
Transitions  
62M 330-640 ERV Unit  
10 to 12 1/2 Ton  
Rooftop Unit  
O/Ahood  
S/A  
Duct  
Optional  
Horizontal  
Economizer  
S/A  
R/A  
Duct  
R/A  
Exhaust hood  
Exhaust hood  
ROOF CURB LOCATION DETAIL  
Rooftop Unit curb  
ERV Curb  
781/4"  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
331/2"  
5513/32"  
A
A
Side View A-A  
9"  
6011/32"  
50"  
331/2"  
Top View  
ROOFTOP UNIT MODEL  
48/50HJ,TF,TJ,TM Without Economizer  
48/50HJ,TF,TJ,TM With Economizer  
ROOFTOP SIZE  
012,014  
TRANSITION P/N  
62M-CTR-HJ1012-H  
62M-CTR-HJ1012-HEC  
ERV CURB P/N  
62M-C-CRB-14M  
62M-C-CRB-14M  
ROOFTOP ECONOMIZER  
012,014  
62MA-900---010  
Fig. 34 — 62MD,ME330-640 Coupled with Carrier 48/50HJ,TF,TJ,TM012,014 Horizontal Discharge Rooftop Unit  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
LEGEND  
62M ERV Unit  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
NOTES:  
1. The ERV unit can be used with a factory-  
installed economizer, if desired.  
2. The ERV cannot be coupled with a hori-  
zontal return 48/50TJ,TM or HJ 15 to  
25 ton rooftop unit.  
Rooftop Unit Curb  
Accessory  
Transition  
ERV curb  
Rooftop Unit  
Accessory  
Transition  
TJ/HJ15to25Ton  
RooftopUnit  
Accessory  
Transition  
62M ERV Unit  
62M330-640  
ERV Unit  
Optional  
Economizer  
O/Ahood  
Exhaust hood  
SideView  
Top View  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
ERV curb  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
A
A
5513/32"  
53 3/4"  
74 1/4"  
SideViewA-A  
11 1/2"  
53 3/4"  
6011/32"  
67 1/16"*  
Top View  
*Length is 891/16for 48/50TM028 units.  
ROOFTOP UNIT  
MODEL  
ROOFTOP SIZE  
TRANSITION P/N  
ERV CURB P/N  
48/50TJ,TM  
48/50HJ  
016-028  
015,017  
62M-BTR-HJ1525-D  
62M-BTR-HJ1525-D  
62M-B-CRB-14S  
62M-B-CRB-14S  
Fig. 35 — 62MD,ME330-640 Coupled with Carrier 48/50TJ,TM016-028 and 48/50HJ015,017  
Vertical Discharge Rooftop Unit  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Rooftop 48/50PG Unit  
Accessory Transition  
(Includes front panel)  
62M ERV Unit  
Supply  
Return  
Accessory Transition  
ERV Wheel  
ERV Curb  
62M330-640 ERV Unit  
LEGEND  
Energy Recovery Ventilator  
ERV  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed economizer  
cannot be used.  
TOP VIEW  
ROOF CURB LOCATION DETAIL  
"
A
38 3/4  
ERV Curb  
60 11/32"  
CurbDetail  
A
A
B
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
55 13/32"  
Return  
38 3/4"  
Supply  
Rooftop Unit Curb  
SideViewA-A  
C
DIMENSIONS (in.)  
B
ROOFTOP UNIT  
MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
923/4  
C
10  
48/50PG  
08-14  
62M-CTR-PG712-D  
62M-C-CRB-14M  
5315  
/
16  
Fig. 36 — 62MD,ME330-640 Coupled with Carrier 48/50PG08-14 Vertical Discharge Rooftop Unit  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Rooftop Unit  
Accessory Transition  
(Includes front panel)  
62M ERV Unit  
Accessory Transition  
ERV Wheel  
ERV Curb  
62M330-640 ERV Unit  
LEGEND  
ERV  
Energy Recovery Ventilator  
NOTE: When using a 62M ERV unit coupled with a Carrier  
rooftop unit, the rooftop factory or field-installed economizer  
cannot be used.  
TOP VIEW  
ROOF CURB LOCATION DETAIL  
38 3/4"  
A
ERV Curb  
60 11/32"  
CurbDetail  
ERV  
Unit  
Curb  
B
A
A
Rooftop  
Unit  
Curb  
38 3/4"  
55 13/32"  
C
SideViewA-A  
Rooftop Unit Curb  
DIMENSIONS (in.)  
B
ROOFTOP UNIT  
MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
923/4  
C
10  
48/50PG  
08-14  
62M-CTR-PG712-H  
62M-C-CRB-14M  
5315  
/
16  
Fig. 37 — 62MD,ME330-640 Coupled with Carrier 48/50PG08-14 Horizontal Discharge Rooftop Unit  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Outside Air Hood (See  
Note 2)  
62M ERV Unit  
Horizontal Return Duct  
(Field Supplied)  
Accessory  
Transition  
Rooftop Unit Curb  
Rooftop Unit  
Accessory  
Transition  
ERV Curb  
62M330-640 ERV Unit  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
NOTES:  
1. The ERV unit can be used with a factory-  
installed economizer, if desired.  
O/A Hood  
2. Transition includes a new outside air hood,  
which allows air intake through the front of  
the hood rather than the bottom. The new  
hood will use the filters from the original  
rooftop unit hood.  
Relief Hood  
Top View  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
44 3/4"  
A
60 11/32"  
CurbDetail  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
44 3/4"  
A
A
B
55 13/32"  
SideViewA-A  
ERV Curb  
Top View  
DIMENSIONS (in.)  
ROOFTOP MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
B
48/50PG  
48/50HJ  
20-28  
62M-CTR-HG1525-H  
62M-CTR-HG1525-H  
62M-C-CRB-14M  
62M-B-CRB-14M  
114.4  
114.4  
78.6  
78.6  
020-028  
Fig. 38 — 62MD,ME330-640 Coupled with Carrier 48/50PG20-28  
and 48/50HJ020-028 Horizontal Discharge Rooftop Unit  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
Outside Air Hood (See  
Note 2)  
62M ERV Unit  
Rooftop Unit Curb  
Accessory  
Transition  
Rooftop Unit  
ERV Curb  
Accessory  
Transition  
62M330-640 ERV Unit  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
NOTES:  
1. The ERV unit can be used with a factory-  
installed economizer, if desired.  
O/A Hood  
2. Transition includes a new outside air hood,  
which allows air intake through the front of  
the hood rather than the bottom. The new  
hood will use the filters from the original  
rooftop unit hood.  
Top View  
Relief Hood  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
44 3/4"  
A
60 11/32"  
CurbDetail  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
A
A
B
44 3/4"  
55 13/32"  
SideViewA-A  
ERV Curb  
Top View  
DIMENSIONS (in.)  
ROOFTOP MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
B
48/50PG  
48/50HJ  
20-28  
62M-CTR-HG1525-D  
62M-CTR-HG1525-D  
62M-C-CRB-14M  
62M-B-CRB-14M  
114.4  
114.4  
78.6  
78.6  
020-028  
Fig. 39 — 62MD,ME330-640 Coupled with Carrier 48/50PG20-28  
and 48/50HJ020-028 Vertical Discharge Rooftop Unit  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOP VIEW  
Accessory  
Transition  
62M ERV Unit  
O/Ahood  
Exhaust hood  
Rooftop Unit  
ROOF CURB LAYOUT  
60.34"  
0"  
55.4"  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
NOTES:  
1. The ERV unit can be used with a factory-  
installed economizer, if desired.  
2. ERV cannot be coupled to a horizontal return  
rooftop unit.  
58 3/4"  
ERV Curb  
Rooftop Unit Curb  
77 3/4"  
SIDE VIEW  
Outside air  
hood  
Rooftop Unit  
62M Unit  
Economizer  
See Note 1  
Accessory  
Transition  
ERV Curb  
Standard  
Rooftop Unit Curb  
ROOFTOP UNIT MODEL  
48/50A  
ROOFTOP SIZE  
020-060  
TRANSITION P/N  
62M-CTR-AJ2060-D  
ERV CURB P/N  
62M-C-CRB-14M  
Fig. 40 — 62MD,ME330-640 Coupled with Carrier 48/50A020-060 Vertical Discharge Rooftop Unit  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
62M ERV Unit  
Rooftop  
Unit Curb  
Accessory  
Transition  
Top View  
Rooftop Unit  
Accessory  
Transition  
ERV Curb  
62M750,950 ERV Unit  
O/AHood  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
NOTES:  
1. The standard factory economizer cannot be  
used when coupled with 62M750,950 units.  
Contact factory for transition with economizer.  
2. 62M750,950 units cannot be used with  
48/50TJ and TM016-028 horizontal discharge  
rooftop units.  
Exhaust Hood  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
ERV Curb  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
31 9/16"  
74 1/4"  
A
A
86.25"  
0"  
Side View A-A  
95.7"  
67.1"*  
319/16"  
Top View  
*Length is 891/16for  
48/50TM028 units.  
ROOFTOP UNIT MODEL  
ROOFTOP SIZE  
TRANSITION P/N  
62M-DTR-HJ1525-D  
62M-DTR-HJ1525-D  
ERV CURB P/N  
62M-D-CRB-14M  
62M-D-CRB-14M  
ROOFTOP ECONOMIZER  
62MA-900---007  
48/50TJ,TM  
48/50HJ  
016-028  
015,017  
62MA-900---007  
Fig. 41 — 62MD,ME750,950 Coupled with Carrier 48/50TJ,TM016-028  
and 48/50HJ015,017 Vertical Discharge Rooftop Unit  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
62M ERV Unit  
Accessory  
Transition  
Rooftop Unit  
Accessory  
Transition  
62M750,950 ERV  
ERV Curb  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
O/A Hood  
NOTE: The ERV unit can be used with a factory-  
installed economizer, if desired.  
Top View  
Relief Hood  
ROOF CURB LOCATION DETAIL  
ERV Curb  
CurbDetail  
A
A
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
B
86 1/4"  
44 3/4"  
SideViewA-A  
A
44 3/4”  
95 3/4"  
Top View  
DIMENSIONS (in.)  
ROOFTOP MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
B
48/50PG  
48/50HJ  
20-28  
62M-DTR-HG1525-H  
62M-DTR-HG1525-H  
62M-D-CRB-14M  
62M-D-CRB-14M  
114.4  
114.4  
78.6  
78.6  
020-028  
Fig. 42 — 62MD,ME750,950 Coupled with Carrier 48/50PG20-28  
and 48/50HJ020-028 Vertical Discharge Rooftop Unit  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
62M ERV Unit  
Rooftop Unit Curb  
Accessory  
Transition  
Rooftop Unit  
Accessory  
Transition  
62M750,950 ERV  
ERV Curb  
LEGEND  
ERV  
O/A  
Energy Recovery Ventilator  
Outdoor Air  
O/A Hood  
NOTE: The ERV unit can be used with a  
factory-installed economizer, if desired.  
Top View  
Relief Hood  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
ERV Curb  
CurbDetail  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
A
A
B
86 1/4"  
44 3/4"  
A
95 3/4"  
44 3/4”  
SideViewA-A  
Top View  
DIMENSIONS (in.)  
ROOFTOP MODEL  
ROOFTOP SIZE  
62M TRANSITION  
ERV CURB  
A
B
48/50PG  
48/50HJ  
20-28  
62M-DTR-HG1525-D  
62M-DTR-HG1525-D  
62M-D-CRB-14M  
62M-D-CRB-14M  
114.4  
114.4  
78.6  
78.6  
020-028  
Fig. 43 — 62MD,ME750,950 Coupled with Carrier 48/50PG20-28  
and 48/50HJ020-028 Vertical Discharge Rooftop Unit  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rooftop Unit  
62M ERV Unit  
Accessory  
Transition  
Unit curb  
ERV Curb  
62M750,950 ERV Unit  
O/AHood  
Accessory  
Transition  
Rooftop Unit  
LEGEND  
Energy Recovery Ventilator  
Outdoor Air  
RETURNAIR  
SUPPLYAIR  
ERV  
O/A  
NOTES:  
1. The standard factory economizer can be used in  
conjunction with 62M750,950 units.  
2. 62M750,950 units cannot be used with horizontal  
discharge rooftop units.  
Exhaust Hood  
ROOF CURB LOCATION DETAIL  
Rooftop Unit Curb  
ERV Curb  
0"  
CURB DETAIL  
ERV  
Unit  
Curb  
Rooftop  
Unit  
Curb  
86.25"  
A
A
579/16"  
Side View A-A  
57 9/16"  
(Seecurb  
detail)  
95.7"  
Top View  
77 3/4"  
ROOFTOP UNIT MODEL  
48/50A  
ROOFTOP SIZE  
TRANSITION P/N  
62M-DTR-AJ2060-D  
ERV CURB P/N  
62M-D-CRB-14M  
020-060  
Fig. 44 — 62MD,ME750,950 Coupled with Carrier 48/50A020-060 Rooftop Unit  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Exhaust hood  
(outdoor units only)  
2 in. pre-filters for  
exhaust  
Exhaust  
Blower  
Outside air hood  
(outdoor units only)  
Top View  
Horizontal Discharge -  
Stand-Alone Unit  
Optional  
Pre-heater  
Supply air  
blower  
2 in. pre-filters for  
outside air  
ERV wheel  
2 in. pre-filters  
exhaust  
ERV Wheel  
Exhaust hood  
(outdoor units only)  
Return/exhaust  
opening in base  
Exhaust  
blower  
Top View  
Down Discharge -  
Stand-Alone Unit  
Optional  
Pre-heater  
Outside air blower,  
mounted over supply  
opening in base  
Optional  
Pre-heater  
Outside air intake hood  
(outside units only)  
2 in. pre-filters  
outside air  
2 in. pre-filters  
outside air  
ERV wheel  
Outside air  
rainhood  
Hinged and latched  
access door (both sides)  
Supply air  
blower  
Side View  
Down Discharge -  
Stand-Alone Unit  
Supply duct for  
outside air (field  
provided)  
Optional ERV  
roof curb  
Fig. 45 — 62M Airflow in Stand-Alone Applications  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 3 — Rigging and Handling — To transfer the  
unit from the shipping platform to the storage or installation  
site, refer to the rigging label on the unit and these instructions.  
Locate the ERV Unit — Prior to locating the indoor ERV unit  
consider the intake and exhaust duct accessibility to outside  
walls or roof vents. When locating the ERV unit consider  
required service clearances.  
Refer to Table 1 for ERV unit weights. Check lifting devices  
for capacity constraints.  
Hook rigging shackles through the holes or lifting eyes in  
the ERV unit.  
See Table 1 for unit weights to determine if building struc-  
NOTE: Some 62M units have lifting eyes, some 62M units  
have holes in the ERV base rail. See Fig. 46.  
Connect lifting straps and spreader bars. See Fig. 46.  
Spreader bars must be positioned to prevent cables from  
rubbing against the ERV unit.  
Carefully lift the ERV unit and set on ERV roof curb. Do  
not drop the ERV unit onto the roof curb, as damage may  
occur. Avoid twisting or uneven lifting of the unit. Never lift  
the unit by the hoods or any means other than the provided  
lifting holes or eyes.  
MOUNTING THE ERV UNIT INDOORS — The ERV unit  
can be mounted indoors. Follow all local and other applicable  
building codes.  
45  
Table 1 — Physical Data  
UNIT 62M  
NOMINAL CAPACITY (cfm)  
CAPACITY RANGE (cfm)  
040  
400  
075  
750  
120  
1200  
170  
1700  
225  
2250  
285  
2850  
100-550  
500-1000  
1000-1400  
1400-2000  
2000-2500  
2500-3200  
MAXIMUM SHIPPING WEIGHT (lb)  
Single-Wall Models  
Double-Wall Models  
255  
367  
440  
635  
462  
657  
850  
1135  
900  
1185  
1000  
1285  
MAXIMUM OPERATING WEIGHT (lb)  
Single-Wall Models  
Double-Wall Models  
235  
347  
400  
595  
422  
617  
790  
1075  
840  
1125  
940  
1225  
62MB,MC INDOOR UNIT DIMENSIONS (in.)  
Length*  
Width  
29.75  
29.88  
29.75  
43.25  
39.13  
37.88  
43.25  
39.13  
37.88  
62.63  
58.38  
48.88  
62.63  
58.38  
48.88  
62.63  
58.38  
48.88  
Height  
62MD,ME OUTDOOR UNIT DIMENSIONS (in.)†  
Length*  
Width  
48.43  
31.24  
29.72  
60.75  
50.13  
37.88  
60.75  
55.13  
37.88  
87.13  
69.38  
48.88  
87.13  
69.38  
48.88  
87.13  
69.38  
48.88  
Height  
ROTARY ENERGY EXCHANGER  
Type  
Size (Diam. x Depth) (in.)  
Nominal Drive Motor Hp  
Enthalpy Lightweight Polymer with Silica Gel Desiccant Coating  
22.5 x 2  
N/A  
29.0 x 2  
29.0 x 3  
40.0 x 1.5  
40.0 x 1.5  
40.0 x 3  
1
/
1
/
1
/
N/A  
N/A  
6
6
6
SUPPLY/EXHAUST AIR FAN  
Qty…Type  
2….Forward Curved Centrifugal  
Adjustable Belt Drive  
Neoprene Pads  
Drive Type  
Direct  
Fan Isolation  
Wheel Dimensions (Diam. x Width)  
Nominal Motor Hp  
5.5 x 5.5  
9 x 7  
2
9 x 7  
1
12 x 12  
1
12 x 12  
2
12 x 12  
2
1
/
1
/
4
FILTERS (optional)  
Type  
2-in. Pleated — 30% Efficiency  
Exhaust Air...Qty...Size (L x W x D) (in.)  
Outside Air...Qty...Size (L x W x D) (in.)  
1….12 x 20 x 2  
1….12 x 20 x 2  
1….18 x 25 x 2  
1….18 x 25 x 2  
1….18 x 25 x 2  
1….18 x 25 x 2  
2….20 x 25 x 2  
2….20 x 25 x 2  
2….20 x 25 x 2  
2….20 x 25 x 2  
2….20 x 25 x 2  
2….20 x 25 x 2  
UNIT 62M  
NOMINAL CAPACITY (cfm)  
CAPACITY RANGE (cfm)  
330  
3300  
430  
4300  
550  
5500  
640  
6400  
750  
7500  
950  
9500  
3000-3600  
3600-5000  
5000-6000  
6000-6800  
6500-8500  
8500-10,500  
MAXIMUM SHIPPING WEIGHT (lb)  
Single-Wall Models  
Double-Wall Models  
1300  
1710  
1350  
1760  
1440  
1850  
1590  
2000  
2650  
3270  
2750  
3370  
MAXIMUM OPERATING WEIGHT (lb)  
Single-Wall Models  
Double-Wall Models  
1220  
1630  
1270  
1680  
1360  
1770  
1510  
1920  
2550  
3170  
2650  
3270  
62MB,MC INDOOR UNIT DIMENSIONS (in.)  
Length  
Width  
73.13  
67.89  
65.21  
73.13  
67.89  
65.21  
73.13  
67.89  
65.21  
73.13  
67.89  
65.21  
108.3  
97.87  
77.4  
108.3  
97.87  
77.4  
Height  
62MD,ME OUTDOOR UNIT DIMENSIONS (in.)†  
Length  
Width  
100.88  
87.89  
65.21  
100.88  
87.89  
65.21  
100.88  
87.89  
65.21  
100.88  
87.89  
65.21  
143.45  
121.87  
77.4  
143.45  
121.87  
77.4  
Height  
ROTARY ENERGY EXCHANGER  
Type  
Size (Diam. x Depth) (in.)  
Nominal Drive Motor Hp  
Enthalpy Lightweight Polymer with Silica Gel Desiccant Coating  
56.2 x 1.5  
56.2 x 1.5  
56.2 x 3  
56.2 x 3  
68.0 x 3  
68.0 x 3  
1
/
1
/
1
/
1
/
1/4**  
1/4**  
2
2
2
2
SUPPLY/EXHAUST AIR FAN  
Qty…Type  
2...Forward Curved Centrifugal  
Adjustable Belt Drive  
Neoprene Pads  
Drive Type  
Fan Isolation  
Wheel Dimensions (Diam. x Width)  
Nominal Motor Hp  
15 x 15  
2
15 x 15  
3
15 x 15  
5
15 x 15  
18 x 18  
18 x 18  
10  
71/2  
71/2  
FILTERS (optional)  
Type  
2-in. Pleated — 30% Efficiency  
Exhaust Air...Qty...Size (L x W x D) (in.)  
Outside Air...Qty...Size (L x W x D) (in.)  
6….16 x 20 x 2  
6….16 x 20 x 2  
6….16 x 20 x 2  
6….16 x 20 x 2  
6….16 x 20 x 2  
6….16 x 20 x 2  
6….16 x 20 x 2  
6….16 x 20 x 2  
6….20 x 24 x 2  
6….20 x 24 x 2  
6….20 x 24 x 2  
6….20 x 24 x 2  
LEGEND  
N/A — Not Applicable  
*Add 10 in. to 62M040 units equipped with a preheater.  
†Dimensions include outdoor air hoods.  
**575-v motors are 1/3 hp.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 4 — Installing ERV Transitions — When cou-  
pling ERV units with Carrier rooftop units an ERV transition is  
required to link the ERV unit and the Carrier rooftop unit  
together.  
IMPORTANT: Only trained, qualified installers and  
service technicians should install, wire, start-up and  
service equipment.  
ERV UNIT COUPLED WITH A 3 to 121/2 TON HVAC  
UNIT — Complete the following steps to install a transition to  
a 3 to 121/2 ton rooftop unit.  
1. Remove the HVAC unit filter door and set aside for later  
use.  
POWER SUPPLY — The electrical characteristics of the  
available power supply must agree with the unit nameplate  
rating. Supply voltage must be within the limits shown. See  
Tables 2 and 3 for electrical and configuration data.  
ELECTRICAL CONNECTIONS — The ERV unit must  
have its own electrical disconnect box. If the disconnect option  
has not been ordered from the factory, it must be field supplied  
and installed per local codes. See Tables 2 and 3.  
If the ERV unit has an electric pre-heater factory installed, it  
will be wired through the ERV unit disconnect.  
NOTE: Most ERV units have electrical interlock safety  
switches on the access doors, which will not allow the ERV  
unit to operate if either of the access doors are opened.  
Low Voltage Wiring — Wire low voltage per diagrams. For  
coupled applications, there will be a brown and black wire in  
the exhaust chamber, which must be tied into the HVAC unit’s  
indoor fan so that when the indoor fan is activated, the ERV  
unit will be activated.  
48/50TJ, HJ 3 to 121/2 Ton Rooftop Units with Economizers  
— The brown and black wires can be plugged into the econo-  
mizer jumper plug on the HVAC unit’s economizer harness.  
Insert the brown wire from the ERV unit into terminal 4 in the  
jumper plug and insert the black wire from the ERV unit into  
terminal 3 in the jumper plug. See Fig. 47.  
2. Remove the panel shipped on the HVAC unit covering  
the return air chamber. This panel can be discarded.  
3. The 62M ERV transition for 3 to 121/2 ton rooftop units  
includes a replacement panel to cover the return opening.  
Install the replacement panel, with hood scoop attached,  
onto the HVAC unit, over the return air chamber. Screw  
in place. The return/exhaust scoop will cover part of the  
return air opening in the HVAC unit.  
NOTE: The standard transition does not seal tight around the  
return air opening on the HVAC unit. This allows for some air  
to flow back to the HVAC unit and some to be drawn back  
through the ERV unit.  
4. Slide the transition between the ERV unit and the HVAC  
unit. Refer to Fig. 17-44 to orient the transition. Line up  
the transition so that it covers the openings in the HVAC  
unit and the ERV unit. The divider in the transition must  
separate the supply and return openings in the ERV unit.  
Screw the mating flanges of the transition to the ERV unit  
through pre-punched holes. Caulk the seams watertight.  
Screw the mating flanges on the other side of the transi-  
tion to the new return air cover panel on the HVAC unit.  
Caulk seams watertight.  
If the 3 to 121/2 ton rooftop unit has an economizer in-  
stalled, the economizer will have an end switch attached to the  
economizer actuator. The end switch must be wired into the  
ERV unit as shown in Fig. 48.  
5. On most models the filter access door shipped with the  
HVAC unit will be reinstalled above the transition.  
For ERV units coupled with units with factory-installed  
economizers, (48/50TM, HJ 15 to 25 ton units 48/50HG, PG 15  
to 25 ton units) the ERV transitions to these rooftop units in-  
clude an economizer end switch. This switch mounts to the hub  
of the economizer damper gear as shown in Fig. 49. Set the end  
switch so that the ERV unit’s outside air blower is deactivated  
during economizer mode.  
For stand-alone units, the ERV unit is jumpered from termi-  
nals 6 and 8 and 7 and 9, providing for continuous operation.  
The ERV unit should be connected to an on-off device such as  
a CO2 sensor.  
6. The transition includes a balancing damper to allow for  
the desired separation of the return/exhaust air between  
the ERV and HVAC units. This damper has a manual  
adjustment. During balancing, this damper will be  
adjusted to achieve desired exhaust cfm. The balancing  
damper can be accessed through a separate door in the  
transition or through the HVAC unit’s filter access door.  
See Fig. 17-44.  
Step 5 — Make Electrical Connections  
High Voltage Wiring (Fig. 50-53) — Connect high voltage  
wiring to the disconnect per Fig. 50, 52 and 53. Check blower  
rotation direction and adjust if necessary.  
Prior to performing service or maintenance operations on  
the ERV unit, turn off and disconnect all power switches to  
the unit. Be aware that there may be more than one discon-  
nect switch. Electrical shock could cause serious personal  
injury or death.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 2 — Electrical Data Without VAV Option  
DISCONNECT  
(Optional)  
EXHAUST AND SUPPLY MOTOR  
POWER SUPPLY  
HEATER  
SIZE  
PRE-HEATER  
(Optional)  
FLA  
UNIT SIZE  
62M  
VOLTAGE  
(V-Ph-Hz)  
ERV WHEEL  
FLA  
Fuse Size*  
(kW)  
NEC - FLA  
Hp  
FLA MCA MOCP  
Amps  
Amps  
12  
30  
5
2
2
2
2
2
2
5
2
5
2
5
2
5
2
5
2
5
2
5
5
8
2
5
2
9.27  
26.64 31.64 31.64  
4.44 4.35 5.66  
13.76 16.37 16.37  
4.11 4.35 5.66  
9.66 11.30 11.30  
9.90 12.87  
17.39  
8.7  
5.03  
2.51  
2.01  
17.39  
43.48  
8.7  
21.74  
5.03  
12.57  
2.51  
6.28  
2.01  
5.03  
17.39  
43.48  
8.70  
21.74  
5.03  
12.57  
2.51  
6.28  
2.01  
5.03  
21.74  
34.78  
43.48  
12.57  
20.11  
25.13  
6.28  
10.05  
12.57  
5.03  
8.04  
10.05  
30  
40  
115-1-60  
230-1-60  
0.7  
3.96  
15  
5
040  
208/230-3-60  
460-3-60  
.6  
10  
3
0.3  
1.74†  
30  
2.34  
4.85  
1.87  
3.75  
2.72  
5.86  
2.17  
4.18  
4.89  
7.40  
3.91  
5
2
4
575-3-60  
6.90  
20.69 24.5  
31.85  
40  
60  
100  
30  
45  
70  
15  
20  
35  
6
115-1-60  
230-1-60  
0.7  
0.3  
0.7  
0.3  
9.8  
4.9  
2.2  
1.1  
0.9  
16  
38.08 46.24 49.24  
64.17 78.85 78.85  
10.46 12.25 15.93  
19.16 23.12 24.62  
30  
60  
32.2  
5.03  
39.42 39.42  
5.50 7.15  
075  
208/230-3-60  
460-3-60  
0.5  
10.05 11.78 12.18  
17.59 21.21 21.21  
12  
20  
4
2.53  
5.04  
2.75  
5.89  
3.58  
6.09  
30  
6
8.81 10.60 10.60  
10  
3
5
2.10  
4.11  
7.13  
2.25  
4.76  
8.53  
2.93  
4.94  
8.53  
575-3-60  
8
33.09 40.00 52.00  
50.48 61.74 69.39  
76.57 94.35 95.48  
16.66 20.00 26.00  
25.36 30.87 34.70  
38.40 47.17 47.74  
9.03 10.50 13.65  
14.05 16.78 18.68  
21.59 26.21 26.22  
60  
80  
200  
30  
40  
60  
30  
30  
40  
50  
60  
90  
25  
30  
45  
12  
18  
25  
6
115-1-60  
230-1-60  
8
120  
208/230-3-60  
460-3-60  
4.2  
2.1  
1.7  
1
4.53  
7.04  
5.25  
8.39  
6.83  
9.34  
8
10.81 13.10 13.11  
12  
5
30  
3.70  
5.71  
4.25  
6.76  
5.53  
7.54  
575-3-60  
6
5
5
8.73 10.53 10.55  
16.93 20.00 26.00  
38.67 47.17 47.74  
51.71 63.48 63.48  
60.41 74.35 74.35  
9.33 10.50 13.65  
21.90 26.21 26.22  
29.44 35.63 35.63  
34.46 41.91 41.91  
10  
25  
45  
60  
70  
12  
25  
35  
40  
6
12  
18  
20  
5
10  
12  
15  
30  
60  
80  
100  
30  
40  
60  
60  
30  
30  
30  
30  
30  
30  
30  
30  
230-1-60  
208/230-3-60  
460-3-60  
8
4.2  
2.1  
1.7  
8
10  
5
8
10  
5
170  
0.6  
1
4.69  
5.25  
6.83  
10.97 13.10 13.11  
14.74 17.82 17.82  
17.26 20.96 20.96  
8
10  
5
8
10  
3.88  
4.25  
5.53  
8.90 10.53 10.55  
11.92 14.30 14.30  
13.93 16.82 16.82  
575-3-60  
LEGEND  
ERV  
Energy Recovery Ventilator  
Full Load Amps  
FLA  
Hp  
Horsepower  
MCA  
MOCP  
NEC  
N/A  
Minimum Circuit Amps  
Maximum Overcurrent Protection  
National Electric Code  
Not Applicable  
*Fused disconnect only.  
†Exhaust and supply fan motors are 230-1-60.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 2 — Electrical Data Without VAV Option (cont)  
DISCONNECT  
(Optional)  
EXHAUST AND SUPPLY MOTOR  
POWER SUPPLY  
HEATER  
SIZE  
PRE-HEATER  
(Optional)  
FLA  
Amps  
UNIT SIZE  
62M  
VOLTAGE  
(V-Ph-Hz)  
ERV WHEEL  
FLA  
Fuse Size*  
(kW)  
NEC - FLA  
Hp  
FLA MCA MOCP  
Amps  
20  
30  
40  
45  
5
8
10  
5
14.53 17.00 22.10  
27.10 32.71 34.67  
34.64 42.13 42.21  
39.66 48.41 48.41  
7.29 8.50 11.05  
13.57 16.35 17.33  
30  
40  
60  
60  
30  
30  
12.57  
20.11  
25.13  
208/230-3-60  
6.8  
10  
15  
6.28  
225  
460-3-60  
0.6  
3.4  
2
49  
Table 2 — Electrical Data Without VAV Option (cont)  
DISCONNECT  
(Optional)  
EXHAUST AND SUPPLY MOTOR  
POWER SUPPLY  
HEATER  
SIZE  
(kW)  
PRE-HEATER  
(Optional)  
FLA  
Amps  
UNIT SIZE  
62M  
VOLTAGE  
(V-Ph-Hz)  
ERV WHEEL  
FLA  
Fuse Size†  
Amps  
NEC - FLA  
Hp  
FLA  
MCA MOCP  
8
10  
15  
8
10  
15  
8
45.53 56.50 72.70  
65.64 81.63 92.81  
70.66 87.91 97.83  
83.23 103.62 110.40  
22.82 29.00 36.95  
32.87 41.57 47.00  
35.38 44.71 49.52  
41.66 52.56 55.80  
18.65 24.00 30.45  
26.69 34.05 38.49  
28.70 36.57 40.50  
33.73 42.85 45.53  
46.83 58.13 74.00  
71.96 89.54 99.13  
84.53 105.25 111.70  
97.09 120.95 124.26  
23.36 29.00 36.95  
35.93 44.71 49.52  
42.21 52.56 55.80  
48.49 60.41 62.08  
19.53 24.25 30.65  
29.58 36.82 40.70  
34.61 43.10 45.73  
39.64 49.38 50.76  
64.46 80.13 102.60  
92.25 114.86 130.39  
106.15 132.23 144.29  
120.04 149.60 158.18  
29.36 36.50 46.70  
41.93 52.21 59.27  
48.21 60.06 65.55  
54.49 67.91 71.83  
23.53 29.25 37.15  
33.58 41.82 47.20  
38.61 48.10 52.23  
43.64 54.38 57.26  
100  
70  
20.11  
25.13  
37.70  
10.05  
12.57  
18.85  
8.04  
10.05  
15.08  
25.13  
37.70  
50.26  
12.57  
18.85  
25.13  
10.05  
15.08  
20.11  
27.79  
41.69  
55.58  
12.57  
18.85  
25.13  
208/230-3-60  
460-3-60  
22  
90  
200  
110  
35  
60  
640  
750  
950  
1.2  
11  
9
45  
60  
80  
40  
50  
30  
35  
40  
45  
70  
90  
575-3-60  
10  
15  
10  
15  
20  
10  
15  
20  
10  
15  
20  
10  
15  
20  
10  
15  
20  
10  
15  
20  
60  
7.5  
100  
200  
208/230-3-60  
460-3-60  
2.5  
1.2  
1.4  
2.5  
1.2  
1.4  
22  
11  
9
110  
35  
45  
50  
60  
30  
40  
45  
50  
100  
60  
80  
80  
40  
575-3-60  
60  
208/230-3-60  
460-3-60  
30.8  
14  
11  
200  
125  
N/A  
45  
50  
60  
70  
35  
45  
60  
80  
80  
10  
100  
60  
80  
10.05  
15.08  
20.11  
575-3-60  
LEGEND  
50  
ERV  
FLA  
Hp  
MCA  
MOCP  
NEC  
N/A  
Energy Recovery Ventilator  
Full Load Amps  
Horsepower  
Minimum Circuit Amps  
Maximum Overcurrent Protection  
National Electric Code  
Not Applicable  
*Fused disconnect only.  
†Exhaust and supply fan motors are 230-1-60.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3 — Electrical Data With VAV Option  
VFD  
EXHAUST AND SUPPLY  
FAN MOTOR  
DISCONNECT  
(Optional)  
POWER SUPPLY  
VFD  
VOLTAGE  
V-Ph-Hz  
ERV  
WHEEL  
FLA  
CURRENT  
INPUT  
HEATER  
SIZE  
(kW)  
PRE-HEATER  
(Optional)  
FLA  
Amps  
UNIT SIZE  
62M*  
Fuse Size†  
Amps  
VALUE  
AMP  
NEC - FLA  
Hp  
FLA  
MCA MOCP  
2
5
2
5
2
5
2
5
2
5
2
5
2
5
5
8
2
5
2
5
5
8
10  
5
19.75 23.00 29.90  
37.14 44.74 47.29  
63.23 77.35 77.35  
11.05 13.02 16.93  
19.74 23.89 25.62  
32.79 40.19 40.19  
17.39  
43.48  
8.70  
21.74  
5.03  
12.57  
2.51  
6.28  
2.01  
5.03  
17.39  
43.48  
8.70  
21.74  
5.03  
12.57  
2.51  
6.28  
2.01  
5.03  
21.74  
34.98  
43.48  
12.57  
20.11  
25.13  
6.28  
10.05  
12.57  
5.03  
8.04  
10.05  
12.57  
20.11  
25.13  
6.28  
10.05  
12.57  
40  
60  
100  
25  
45  
70  
15  
25  
40  
8
12  
20  
5
115-1-60  
230-1-60**  
208/230-3-60  
460-3-60  
0.7  
0.3  
0.7  
0.3  
9.2  
5.2  
2.8  
1.5  
2.1  
16.6  
9.6  
5.3  
2.6  
2.1  
30  
60  
2.2  
6.26  
7.03  
9.14  
075  
0.5  
11.28 13.31 14.17  
18.82 22.74 22.74  
3.24  
5.76  
3.65  
6.79  
4.74  
7.25  
1.1  
0.9  
30  
6
10  
6
9.53 11.50 11.50  
4.41  
6.42  
5.13  
7.64  
6.67  
8.68  
575-3-60  
8
9.43 11.41 11.69  
34.55 41.50 53.95  
51.94 63.24 71.34  
78.03 95.85 97.43  
19.80 23.96 31.15  
28.49 34.83 39.84  
41.54 51.13 52.88  
11.26 13.28 17.27  
16.28 19.56 22.29  
23.82 28.99 29.83  
10  
50  
70  
90  
30  
35  
50  
15  
20  
25  
8
80  
100  
200  
40  
60  
80  
30  
30  
40  
115-1-60  
230-1-60**  
208/230-3-60  
460-3-60  
4.2  
120  
1
5.53  
8.05  
6.51  
9.65 10.98  
8.46  
2.1  
1.7  
10  
12  
6
11.82 14.36 14.75  
30  
4.41  
6.42  
5.13  
7.64  
6.67  
8.68  
575-3-60  
8
9.43 11.41 11.69  
20.10 23.96 31.15  
41.84 51.13 52.88  
54.88 67.44 67.44  
63.57 78.31 78.31  
11.56 13.28 17.27  
24.12 28.99 29.83  
31.66 38.41 38.41  
36.69 44.70 44.70  
10  
30  
50  
60  
70  
15  
25  
35  
40  
8
40  
80  
80  
100  
30  
40  
230-1-60**  
208/230-3-60  
460-3-60  
9.6  
5.3  
2.6  
2.1  
8.2  
4.2  
3.6  
4.2  
8
60  
60  
10  
5
170  
0.6  
1
5.70  
6.51  
8.46  
11.98 14.36 14.75  
15.75 19.08 19.08  
18.26 22.22 22.22  
12  
17.5  
20  
6
2.1  
1.7  
6.8  
3.4  
2.7  
8
10  
5
30  
4.58  
5.13  
6.67  
9.61 11.41 11.69  
12.62 15.18 15.18  
14.63 17.69 17.69  
17.39 20.57 26.74  
29.95 36.28 39.31  
37.49 45.70 46.85  
42.52 51.99 51.99  
8.82 10.42 13.54  
15.11 18.27 19.82  
18.88 22.98 23.59  
21.39 26.12 26.12  
10  
15  
17.5  
25  
35  
45  
50  
12  
17.5  
20  
25  
10  
15  
17.5  
20  
575-3-60  
8
10  
5
40  
60  
30  
40  
208/230-3-60  
460-3-60  
8
10  
5
225  
0.6  
2
8
10  
5
8
10  
7.66  
8.97 11.66  
12.68 15.26 16.69  
15.70 19.03 19.71  
17.71 21.54 21.72  
5.03  
8.04  
10.05  
575-3-60  
30  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3 — Electrical Data With VAV Option (cont)  
VFD  
CURRENT  
INPUT  
VALUE  
AMP  
EXHAUST AND SUPPLY  
FAN MOTOR  
DISCONNECT  
(Optional)  
POWER SUPPLY  
VFD  
VOLTAGE  
V-Ph-Hz  
ERV  
WHEEL  
FLA  
HEATER  
SIZE  
(kW)  
PRE-HEATER  
(Optional)  
FLA  
Amps  
UNIT SIZE  
62M*  
Fuse Size†  
Amps  
NEC - FLA  
Hp  
FLA  
MCA MOCP  
5
8
17.39 20.57 26.74  
29.95 36.28 39.31  
37.49 45.70 46.85  
42.52 51.99 51.99  
40  
60  
25  
35  
45  
50  
12.57  
20.11  
25.13  
208/230-3-60  
8.2  
6.8  
10  
285  
0.6  
2
LEGEND  
*The VAV option is not available on 62M040 units.  
†Fused disconnect only.  
**Exhaust and supply fan motors are 230-3-60.  
52  
Table 3 — Electrical Data With VAV Option (cont)  
VFD  
CURRENT  
INPUT  
VALUE  
AMP  
EXHAUST AND SUPPLY  
FAN MOTOR  
DISCONNECT  
(Optional)  
POWER SUPPLY  
PRE-  
HEATER  
(Optional)  
FLA  
VFD  
VOLTAGE  
V-Ph-Hz  
ERV  
WHEEL  
FLA  
HEATER  
SIZE  
(kW)  
UNIT SIZE  
62M*  
Fuse Size†  
NEC - FLA  
Hp  
FLA  
MCA MOCP  
Amps  
Amps  
8
10  
15  
8
10  
15  
8
53.61 65.10 84.64  
73.72 90.24 104.74  
78.75 96.52 109.77  
91.31 112.23 122.33  
26.65 32.29 41.98  
36.70 44.86 52.03  
39.21 48.00 54.55  
45.50 55.85 60.83  
23.62 28.71 37.33  
31.66 38.76 45.37  
33.67 41.28 47.38  
38.70 47.56 52.40  
54.91 65.10 84.64  
80.05 96.52 109.77  
92.61 112.23 122.33  
105.18 127.93 134.90  
27.20 32.29 41.98  
39.76 48.00 54.55  
46.05 55.85 60.83  
52.33 63.71 67.11  
24.50 28.71 37.33  
34.55 41.28 47.38  
39.58 47.56 52.40  
44.61 53.84 57.43  
70.86 85.00 110.50  
98.65 119.74 138.29  
112.55 137.11 152.19  
126.44 154.48 166.08  
34.28 41.15 53.49  
46.85 56.85 66.06  
53.13 64.71 72.34  
59.41 72.56 78.62  
29.63 35.12 45.66  
39.68 47.69 55.71  
44.71 53.97 60.74  
49.73 60.25 65.76  
100  
200  
80  
100  
100  
110  
40  
50  
50  
60  
35  
45  
45  
50  
80  
100  
110  
125  
40  
50  
60  
20.11  
25.13  
37.70  
10.05  
12.57  
18.85  
8.04  
10.05  
15.08  
25.13  
37.70  
50.26  
12.57  
18.85  
25.13  
10.05  
15.08  
20.11  
27.79  
41.69  
55.58  
12.57  
18.85  
25.13  
208/230-3-60  
460-3-60  
26  
12.9  
11.5  
26  
22  
60  
80  
640  
750  
950  
1.2  
11  
9
60  
575-3-60  
10  
15  
10  
15  
20  
10  
15  
20  
10  
15  
20  
10  
15  
20  
10  
15  
20  
10  
15  
20  
80  
100  
7.5  
208/230-3-60  
460-3-60  
2.5  
1.2  
1.4  
2.5  
1.2  
1.4  
22  
11  
9
200  
60  
12.9  
11.5  
34  
80  
60  
35  
45  
50  
60  
80  
575-3-60  
50  
110  
125  
N/A  
N/A  
50  
60  
70  
70  
45  
208/230-3-60  
460-3-60  
30.8  
14  
11  
200  
80  
16.5  
14  
10  
100  
60  
10.05  
15.08  
20.11  
50  
60  
60  
575-3-60  
LEGEND  
80  
ERV  
FLA  
Hp  
Energy Recovery Ventilator  
Full Load Amps  
Horsepower  
MCA  
MOCP  
NEC  
N/A  
Minimum Circuit Amps  
Maximum Overcurrent Protection  
National Electric Code  
Not Applicable  
VFD  
Variable Frequency Drive  
*The VAV option is not available on 62M040 units.  
†Fused disconnect only.  
**Exhaust and supply fan motors are 230-3-60.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
19  
18  
17  
16  
15  
14  
Economizer  
harness/plug coming  
from control box in  
HVAC unit.  
Actuator  
(Motor)  
Black  
Important: Remove  
and re-install through  
end switch  
Jumper  
in plug  
leave.  
Economizer  
End switch  
Jumper plug  
shipped attached  
economizer plug.  
Fig. 48 — Economizer End Switch Wiring  
Brown  
Fig. 47 — Jumper Plug Detail  
20  
19  
Economizer  
Switch  
Economizer  
Gear hub  
18  
17  
16  
15  
14  
Switch  
Bracket  
Fig. 49 — Economizer Switch Wiring  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
55  
56  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
START-UP  
Use the following information and the Start-Up Checklist  
on page CL-1 to check unit PRIOR to start-up.  
Unit Preparation — Check that the unit has been in-  
stalled in accordance with these installation instructions and all  
applicable codes.  
Check all fasteners and set screws for tightness. This is  
critical for bearings and fan wheels. Also, if dampers are not  
motorized, check that they open and close without binding.  
Internal Wiring — Check all electrical connections in the  
control box. Tighten as required.  
Rain Hoods — Some ERV units will require the outside  
air and/or exhaust hood to be field installed. Caulk coupled  
flanges and screw to ERV unit.  
NOTE: Units for indoor applications will not have rain hoods.  
The outside air hood will include aluminum water entrain-  
59  
0.8  
0.7  
0.6  
0.5  
0.4  
62M040  
62M120  
62M075  
0.3  
0.2  
200  
400  
600  
800  
1000  
1200  
1400  
Airflow (cfm)  
*Data based on measurements taken using optional airflow test ports.  
Fig. 54 — 62M040-120 ERV Wheel Pressure Drop*  
1.2  
1.1  
62M330,430  
1
0.9  
0.8  
62M285  
62M170,225  
0.7  
0.6  
0.5  
0.4  
1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000  
Airflow (cfm)  
*Data based on measurements taken using optional airflow test ports.  
Fig. 55 — 62M170-430 ERV Wheel Pressure Drop*  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2  
1.1  
1
62M550,640  
62M750,950  
0.9  
0.8  
0.7  
0.6  
0.5  
5000  
5500  
6000  
6500  
7000  
7500  
8000  
8500  
9000  
9500  
10000 10500 11000  
Airflow (cfm)  
*Data based on measurements taken using optional airflow test ports.  
Fig. 56 — 62M550-950 ERV Wheel Pressure Drop* (cont)  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
600  
500  
400  
Supply Air High Speed  
Supply Air Speed Three  
Supply Air Speed Two  
Supply Air Low Speed  
300  
200  
100  
0
0.00  
0.20  
0.40  
0.60  
0.80  
1.00  
1.20  
1.40  
1.60  
External Static Pressure (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 57 — 62M040 Supply Air Fan Performance Curves  
600  
500  
400  
300  
200  
100  
0
Exhaust Air High Speed  
Exhaust Air Speed Three  
Exhaust Air Speed Two  
Exhaust Air Low Speed  
0.00  
0.20  
0.40  
0.60  
0.80  
1.00  
1.20  
1.40  
1.60  
External Static Pressure (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 58 — 62M040 Exhaust Air Fan Performance Curves  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1400  
1200  
1000  
800  
600  
400  
200  
0
1112 rpm: 2 turns  
1058 rpm: 3 turns  
1002 rpm: 4 turns  
942 rpm: 5 turns  
0.1  
0.3  
0.5  
0.7  
0.9  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 59 — 62M075 Supply Air Fan Performance Curves  
1200  
1000  
800  
600  
400  
200  
0
1136 rpm: 2 turns  
1081 rpm: 3 turns  
1010 rpm: 4 turns  
946 rpm: 5 turns  
0.1  
0.2  
0.3  
0.4  
0.5  
0.6  
0.7  
0.8  
0.9  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 60 — 62M075 Exhaust Air Fan Performance Curves  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1575  
1375  
11 75  
975  
1448 rpm: 2 turns  
1315 rpm: 3 turns  
1277 rpm: 4 turns  
1194 rpm: 5 turns  
775  
575  
375  
0.2  
0.4  
0.6  
0.8  
1
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 61 — 62M120 Supply Air Fan Performance Curves  
1475  
1275  
1075  
875  
1399 rpm: 2 turns  
1332 rpm: 3 turns  
1244 rpm: 4 turns  
1162 rpm: 5 turns  
675  
475  
275  
0.2  
0.4  
0.6  
0.8  
1.0  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 62 — 62M120 Exhaust Air Fan Performance Curves  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2800  
2600  
2400  
2200  
2000  
1800  
1600  
1400  
1200  
1000  
1121 rpm: 3 turns  
1074 rpm: 4 turns  
1017 rpm: 5 turns  
937 rpm: 6 turns  
0.2  
0.4  
0.6  
0.8  
1
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 63 — 62M170 Supply Air Fan Performance Curves  
2600  
2400  
2200  
2000  
1800  
1600  
1400  
1200  
1000  
1068 rpm: 3 turns  
1045 rpm: 4 turns  
1018 rpm: 5 turns  
977 rpm: 6 turns  
0.2  
0.4  
0.6  
0.8  
1
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 64 — 62M170 Exhaust Air Fan Performance Curves  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3000  
2500  
2000  
1500  
1000  
1159 rpm: 3 turns  
1114 rpm: 4 turns  
1054 rpm: 5 turns  
0.2  
0.4  
0.6  
0.8  
1
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 65 — 62M225 Supply Air Fan Performance Curves  
3000  
2500  
2000  
1500  
1000  
1077 rpm: 3 turns  
1052 rpm: 4 turns  
1024 rpm: 5 turns  
964 rpm: 6 turns  
0.2  
0.4  
0.6  
0.8  
1
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 66 — 62M225 Exhaust Air Fan Performance Curves  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3500  
3000  
2500  
2000  
1500  
1000  
1186 rpm: 2 turns  
1109 rpm: 3 turns  
1057 rpm: 4 turns  
1010 rpm: 5 turns  
0.1  
0.3  
0.5  
0.7  
0.9  
1.1  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 67 — 62M285 Supply Air Fan Performance Curves  
3500  
3000  
2500  
1193 rpm: 2 turns  
1147 rpm: 3 turns  
1097 rpm: 4 turns  
1062 rpm: 5 turns  
2000  
1500  
1000  
0.1  
0.3  
0.5  
0.7  
0.9  
1.1  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 68 — 62M285 Exhaust Air Fan Performance Curves  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4500  
4000  
3500  
3000  
2500  
2000  
833 rpm: 2 turns  
803 rpm: 3 turns  
763 rpm: 4 turns  
0.10  
0.20  
0.30  
0.40  
0.50  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 69 — 62M330 Supply Air Fan Performance Curves  
4000  
3800  
3600  
3400  
3200  
3000  
2800  
2600  
2400  
2200  
2000  
842 rpm: 2 turns  
808 rpm: 3 turns  
770 rpm: 4 turns  
0.13  
0.20  
0.30  
0.40  
0.50  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 70 — 62M330 Exhaust Air Fan Performance Curves  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5500  
5000  
4500  
4000  
3500  
3000  
2500  
962 rpm: 3 turns  
942 rpm: 4 turns  
891 rpm: 5 turns  
0. 20  
0. 40  
0. 60  
0. 80  
1. 00  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 71 — 62M430 Supply Air Fan Performance Curves  
5500  
5000  
4500  
4000  
3500  
3000  
2500  
871 rpm: 4 turns  
891 rpm: 5 turns  
0. 20  
0. 40  
0. 60  
0. 80  
1. 00  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 72 — 62M430 Exhaust Air Fan Performance Curves  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6500  
6000  
5500  
5000  
4500  
4000  
3500  
3000  
2500  
2000  
1109 rpm: 2 turns  
1068 rpm: 3 turns  
1014 rpm: 4 turns  
968 rpm: 5 turns  
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 73 — 62M550 Supply Air Fan Performance Curves  
6500  
6000  
5500  
5000  
4500  
4000  
3500  
3000  
2500  
2000  
1109 rpm: 2 turns  
1049 rpm: 3 turns  
998 rpm: 4 turns  
947 rpm: 5 turns  
0.3  
0.4  
0.6  
0.8  
1.0  
1.2  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 74 — 62M550 Exhaust Air Fan Performance Curves  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7500  
7000  
6500  
6000  
5500  
5000  
1256 rpm: 2 turns  
1174 rpm: 3 turns  
1150 rpm: 4 turns  
0.25  
0.45  
0.65  
0.85  
1.00  
1.20  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 75 — 62M640 Supply Air Fan Performance Curves  
8000  
7500  
7000  
6500  
6000  
5500  
5000  
1202 rpm : 0 turns  
1152 rpm: 1 turn  
1123 rpm: 2 turns  
1096 rpm: 3 turns  
0.4  
0.5  
0.6  
0.7  
0.9  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 76 — 62M640 Exhaust Air Fan Performance Curves  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9500  
9000  
8500  
8000  
7500  
7000  
6500  
6000  
5500  
906 rpm: 0 turns  
870 rpm: 1 turns  
847 rpm: 2 turns  
821 rpm: 3 turns  
807 rpm: 4 turns  
0.10  
0.30  
0.50  
0.70  
0.90  
1.10  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 77 — 62M750 Supply Air Fan Performance Curves  
9000  
8500  
8000  
7500  
7000  
6500  
6000  
5500  
923 rpm : 0 turns  
898 rpm: 1 turn  
862 rpm: 2 turns  
844 rpm: 3 turns  
813 rpm: 4 turns  
0.3  
0.5  
0.7  
0.9  
1.1  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 78 — 62M750 Exhaust Air Fan Performance Curves  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11500  
11000  
10500  
10000  
9500  
9000  
8500  
8000  
7500  
7000  
6500  
966 rpm: 3 turns  
896 rpm: 4 turns  
831 rpm: 5 turns  
0.10  
0.30  
0.50  
0.70  
0.90  
1.10  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 79 — 62M950 Supply Air Fan Performance Curves  
11000  
10500  
10000  
9500  
9000  
8500  
8000  
7500  
7000  
1024 rpm: 3 turns  
962 rpm: 4 turns  
929 rpm: 5 turns  
0.3  
0.5  
0.7  
0.9  
1.1  
External Static (in. wg)  
NOTE: Fan data includes pressure drop for 30% efficient 2-in. filters.  
Fig. 80 — 62M950 Exhaust Air Fan Performance Curves  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Occupied Mode, with CO2 Sensor — When the CO2 sensor  
is used, it will measure the space CO2 levels in parts per  
million (ppm). The 62M ERV CO2 setting is factory set at  
1,000 ppm but can be adjusted from 0 ppm to 2,000 ppm.  
When either the scheduling program and/or the CO2 sensor  
calls for ERV operation, the ERV will activate the following:  
ERV wheel  
Outdoor air blower motor  
EXH blower motor  
Two-position damper opens  
NOTE: The two-position damper option may slightly delay  
activation of the ERV blower motor.  
Occupied Mode, with Frost Protection — In the occupied  
mode, the frost protection option will eliminate frost build-up  
on the ERV wheel using exhaust air. It is activated via a  
pressure differential across the ERV wheel. This set point is  
field set from 0.2 in. wg to 2.0 in. wg and must be set to 150%  
of the normal static pressure across the wheel. The frost protec-  
tion feature is automatically locked out above 35 F.  
NOTE: If the outdoor-air temperature is below 35 F, a dirty  
wheel may incorrectly activate the frost control feature if the  
differential pressure across the wheel exceeds the set point.  
Fig. 81 — Blower Motor Pulley Adjustment  
When the frost protection option is activated the following  
will occur:  
ERV wheel turns on.  
Outdoor air blower motor turns off.  
EXH blower motor is on.  
Occupied Mode, with the Pre-Heat Option — In the occu-  
pied mode, the pre-heat option provides frost protection for the  
ERV wheel and slightly warms the outdoor air. This feature is  
factory set to activate at –5 F, and can be field adjusted from  
–30 F to 100 F. It is recommended that this set point be set at  
the frost threshold for the region in which it is used.  
If desired, this feature may also be activated via a field  
supplied pressure differential switch to determine if frost build  
up has occurred on the ERV wheel.  
Occupied Mode, with the Economizer Accessory — When  
using the economizer option, this allows for up to 100%  
outside air to be brought in for free cooling. During free  
cooling, the rooftop unit mechanical cooling may or may not  
be operating depending on the set points used with the rooftop  
unit. When using the economizer accessory, it is recommended  
that the minimum position be set to the closed position and the  
ERV should be set such that it is locked out when the econo-  
mizer opens far enough to bring in the same level of outdoor air  
as the ERV.  
Fig. 82 — Belt Alignment  
If desired, this feature may also be activated via a  
field-supplied pressure differential switch to determine if frost  
build- up has occurred on the ERV wheel.  
Variable Air Volume Option — This option can be  
used in conjunction with the CO2 sensor option (ordered  
separately). Outside air and exhaust air blower speeds are  
independently controlled by variable frequency drives and  
modulated based upon space occupancy, which can be  
measured by CO2. The more people in the space the greater the  
CO2 levels, the more outside air is introduced. This option  
eliminates over ventilating the space in less than full condi-  
tions. The ERV unit has completely different electrical charac-  
teristics when used with a variable air volume option. Refer to  
Tables 2 and 3.  
During free cooling, the following occurs:  
ERV wheel is turned off.  
Outdoor air blower is turned off.  
EXH blower motor turns on.  
Two-position outdoor-air damper is closed (if used).  
Two-position EXH damper is opened (if used).  
Stop/jog option will periodically rotate the ERV wheel  
to clean it during wheel bypass operation. This feature is  
factory set to activate every 10 minutes, for 20 seconds  
of operation. Both settings can be adjusted from 0 to 10  
minutes.  
Operating Sequence  
Wheel Bypass Option — When using the wheel bypass option  
(with the stop/jog option), this allows free cooling through the  
wheel limited by the ERV airflow cfm limits. With this option  
the unit can be in free cooling or not depending on the tempera-  
ture of the outdoor-air compared to the set point. When not in  
free cooling, the ERV will not operate. When in free cooling:  
OCCUPIED MODE — While in occupied mode, the 62M  
ERV will operate per the ERV Timer option (scheduling  
program), the CO2 sensor input, a combination of the schedul-  
ing option and CO2 input, or the economizer accessory.  
Additionally, the low temperature lockout (LTLO) function  
locks out the 62M ERV if the outdoor-air temperature entering  
the wheel is below the set point. The LTLO is factory set at  
–10 F, and can be field adjusted from –30 F to 100 F.  
ERV wheel is turned off.  
Outdoor-air blower is turned on.  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXH blower motor is turned on.  
To install the segments see the Installing Wheel Segments  
(62M075-950) section.  
The two-position damper is open (if used).  
The stop/jog option will periodically rotate the ERV  
wheel to clean it during wheel bypass operation. This  
feature is factory set to activate every 10 minutes, for  
20 seconds of operation. Both settings can be adjusted  
from 0 to 10 minutes.  
Removing and Installing Non-Segmented Wheel  
for Cleaning (62M040 Units) — Non-segmented ener-  
gy transfer wheels are secured to the shaft and bearing support  
beam by a Phillips head screw and hub cover. See Fig. 84.  
To remove the energy transfer wheel, follow Steps 1-4  
below. (See Fig. 84.) Reverse procedure for wheel installation.  
1. Remove front seal assembly (pulley side of cassette) if  
present.  
2. Remove belt from pulley and position temporarily around  
wheel rim.  
3. Remove the hub cover from the wheel. Note the wheel to  
shaft alignment pin under the hub cover. Ensure this pin  
engages the notch at the end of the shaft when reinstalling  
the wheel.  
UNOCCUPIED MODE — While in unoccupied mode, when  
below the low temperature lockout set point, the ERV wheel is  
off, and only the two-position damper option is opened to  
allow free cooling when desired. The dampers are controlled  
by either the ERV Timer option (scheduling program) or the  
CO2 sensor input. Additionally, the frost protection and preheat  
options are also off. The low temperature lockout (LTLO)  
function locks out the 62M ERV if the outdoor-air temperature  
entering the wheel is below the set point. The LTLO is factory  
set at –10 F, and can be field adjusted from –30 F to 100 F.  
When above the low temperature lockout set point and  
cooling is desired the economizer or wheel bypass option is  
also used. Depending on the option used with the 62M ERV,  
several sequences of operation could occur.  
4. Pull the wheel straight off the shaft. Handle wheel with  
care to prevent distorting of the wheel.  
Unoccupied Mode, with the Economizer Accessory — When  
using the economizer option, this allows for up to 100% out-  
side air to be brought in for free cooling. During free cooling,  
no mechanical cooling is operating and the following occurs:  
ERV wheel is turned off.  
Outdoor air blower motor is off.  
EXH blower motor is off.  
Two-position OA damper option is closed (if used).  
Two-position EXH damper is open (if used).  
The stop/jog option will periodically rotate the ERV  
wheel to clean it during wheel bypass operation.  
When using the economizer option and mechanical cooling  
is operating, the economizer should be closed or at the mini-  
mum position.  
Unoccupied Mode, with the Wheel Bypass Option — When  
using the wheel bypass option (with the stop/jog option), this  
allows free cooling through the wheel limited by the ERV cfm  
limits. With this option the unit can be in free cooling or not  
depending on the temperature of the OA compared to the  
set point. When in free cooling:  
Fig. 83 — Unlocking the  
Segment Retaining Brackets  
ERV wheel is turned off.  
Outdoor air blower is on.  
EXH blower motor is on.  
Two-position damper is open (if used).  
When not in free cooling:  
ERV wheel is turned off.  
Outdoor air blower motor is turned off.  
EXH blower motor is turned off.  
Two-position damper is closed (if used).  
Alignment  
Cassette  
Pin  
Housing/Frame  
SERVICE  
Shaft  
Disconnect electrical power before servicing energy recov-  
ery cassette.  
Removing Wheel Segments for Cleaning  
(62M170-950 Units)  
Bearings (2)  
1. Unlock and open the segment retaining brackets on both  
Wheel &  
Hub  
Hub Cover  
sides of the selected segment opening. Refer to Fig. 83.  
2. Gently lift segment outward.  
3. Close segment retaining latches and rotate wheel 180 de-  
grees to remove next segment. Follow this pattern to  
remove all segments. This pattern will help keep wheel  
balanced.  
Fig. 84 — 62M040 Energy  
Transfer Wheel Assembly  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing and Installing Non-Segmented  
Wheel for Cleaning (62M075, 120 Units) —  
Non-segmented energy transfer wheels include the shaft and  
are secured to two wheel support beams by two flange bearings  
with locking collars. See Fig. 85.  
To remove the energy transfer wheel follow Steps 1-4  
below. Reverse procedure for wheel installation.  
WHEEL,  
HUB &  
SHAFT  
FLANGE  
BEARINGS  
(2)  
1. Pull the wheel with shaft straight out of the motor side  
wheel support beam and bearing. Handle wheel with care  
to prevent distorting of the wheel.  
2. Remove the pulley side wheel support beam with bearing  
by removing the 4 support beam screws.  
3. Remove the belt from the pulley and position temporarily  
around the wheel rim.  
SET  
SCREWS  
(2) EACH  
4. Loosen the two set screws on each of the two wheel  
bearings. See Fig. 85.  
When replacing wheel, retighten the 4 bearing set screws.  
Premature bearing failure could result.  
WHEEL SUPPORT BEAMS  
Fig. 85 — 62M075,120 Energy  
Transfer Wheel Assembly  
Installing Wheel Segments (62M170-950  
Units)  
Before performing service or maintenance operations on  
unit, turn off main power switch to unit. Electrical shock  
could cause personal injury.  
HAMMER  
USED AS  
NOTE: Both installation and removal procedures must be per-  
formed from the pulley side of the cassette.  
STOP”  
Weight of the installed segment will cause the wheel to  
accelerate in rotation. Failure to maintain control of the  
wheel rotation while installing all segments could cause  
severe injury to fingers or hand caught between revolving  
spokes and the bearing support beam. Handle of hammer,  
or other stop, should be inserted through spokes and above  
or below bearing support beams to limit rotation of unbal-  
anced wheel. See Fig. 86.  
Fig. 86 — Using a Stop on the Wheel  
NOTE: The 62M040-120 units contain non-segmented wheels  
which must be completely removed to be cleaned.  
1. Begin by positioning one segment opening at the top of  
the cassette. Unlock and open the segment retaining  
brackets on both sides of the selected segment opening.  
2. Holding the segment as vertical as possible and  
centered between spokes, insert nose of segment down-  
ward between the hub plates. See Fig. 87.  
NOTE: The face of the segment, with the imbedded  
stiffener (vertical support between nose and rim end of  
segment) must face the motor side of the cassette. See  
Fig. 88.  
3. Ease the segment downward until its outer rim clears the  
inside of the wheel rim. Then press the segment inward  
against the spoke flanges.  
4. Close and latch segment retaining brackets to the position  
shown in Fig. 89. Make certain the retaining bracket is  
fully engaged under the catch.  
5. Slowly rotate, by hand, the first installed segment to the  
bottom of the cassette, then install the second segment  
opposite the first. Repeat this sequence with the two  
installed segments rotated to the horizontal position to  
balance the weight of installed segments. Continue this  
sequence with the remaining segments.  
Fig. 87 — Inserting a Segment of the Wheel  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Using hexagonal wrench, loosen setscrew in bearing  
locking collar. Using light hammer and drift (in drift pin  
hole) tap collar in the direction of wheel rotation to  
unlock collar. Remove collar.  
Imbedded Stiffeners  
3. Using socket wrench with extension, remove two nuts  
which secure bearing housing to the bearing support  
beam. Slide bearing from shaft.  
NOTE: Slight hand pressure against wheel rim will  
lift weight of wheel from inner race of bearing to assist  
bearing removal and installation. If not removable by  
hand, use bearing puller.  
Fig. 88 — Motor Side View of Segment  
Protect hands and belt from possible sharp edges of hole in  
bearing support beam.  
4. Using a wrench, remove diameter seal retaining screws or  
hub seal retaining screws. Remove diameter seals or hub  
seal from bearing beam. See Fig. 91.  
5. Form a small loop of belt and pass it through the hole in  
the bearing support beam. Grasp the belt at the wheel hub  
and pull the entire belt down. Loop the trailing end of the  
belt over the shaft (Fig. 91 shows belt partially through  
the opening).  
6. Reinstall the bearing onto the wheel shaft, being careful  
to engage the two locating pins into the holes in the  
bearing support beam. Secure the bearing with two  
self-locking nuts.  
PULL TAB  
CATCH  
Fig. 89— Latch Segment Retaining Brackets  
Wheel Drive Motor and Pulley Replacement  
(62M170-095 Units)  
1. Disconnect power to wheel drive motor.  
2. Remove belt from pulley and position temporarily around  
wheel rim.  
3. Loosen setscrew in wheel drive pulley using Allen  
wrench and remove pulley from motor drive shaft.  
4. While supporting weight of drive motor in one hand,  
loosen and remove 4 mounting bolts.  
5. Install replacement motor with hardware kit supplied.  
6. Install pulley to dimension shown in Fig. 90 and secure  
setscrew to drive shaft.  
7. Stretch belt over pulley and engage in groove.  
7. Install the belts around the wheel and pulley according to  
the instructions provided with the belt.  
8. Reinstall diameter seals or hub seal and tighten retaining  
screws. Rotate wheel in clockwise direction to determine  
that wheel rotates freely with slight drag on seals.  
9. Reinstall bearing locking collar. Rotate collar by hand in  
the direction the wheel rotates (see label provided on each  
cassette for wheel rotation). Lock in position by tapping  
drift pin hole with hammer and drift. Secure in position  
by tightening setscrew.  
10. Reinstall bearing access cover.  
11. Apply power to wheel and ensure that the wheel rotates  
freely without interference.  
ALTERNATE BELT REPLACEMENT METHODS — Alter-  
nate belt replacement methods may be used in some applica-  
tions depending upon accessibility of the cassette. Consult  
instructions provided with the belt for further information.  
Belt Replacement  
1. Obtain access to the pulley side bearing access plate.  
Remove two bearing access plate retaining screws and  
the access plate.  
Insulation  
Seal  
Plate  
62M  
ERV  
WHEEL DIMENSION A  
UNIT SIZE WHEEL SERIES  
(in.)  
Dimension A  
170  
225  
285  
330  
430  
550  
640  
750  
950  
ERC-3623  
ERC-3623  
ERC-3628  
ERC-5245  
ERC-5245  
ERC-5262  
ERC-5262  
ERC-6488  
ERC-6488  
36  
36  
36  
52  
52  
52  
52  
64  
64  
Wheel  
Drive  
Motor  
1
/
4
Pulley  
7
/
16  
NOTE: The ERV wheel model number contains the wheel series number,  
and is located on a label near the drive pulley. For example, ERC-5245D is  
a 52 series wheel.  
Fig. 90 — Pulley Location  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Belt (Shown in  
Place)  
Locking  
Collar  
Bearing  
Support  
Beam  
Wheel Rim  
Locking  
Nut (2)  
Wheel  
Bearing  
Access Plate  
Bearing  
Housing  
Hub (2)  
Taper - Lock  
Hub Collar (2)  
Retaining  
Screws  
Set Screw  
Shaft  
Drift Hole  
Locating Pin  
PULL  
FEED  
Belt  
Pulley  
Side  
Motor  
Side  
Fig. 91 — Belt Replacement (Diameter Seals Removed)  
MAINTENANCE  
To clean, gain access to the energy recovery wheel and  
remove wheel. Brush foreign material from the face of the  
wheel. Wash the wheel in a 5% solution of non-acid based coil  
cleaner or alkaline detergent and warm water.  
Routine maintenance of the energy recovery cassettes  
includes periodic cleaning of the energy recovery wheel as well  
as inspection of the air seals and wheel drive components as  
follows:  
Soak in the solution until grease and tar deposits are  
loosened.  
Cleaning — The need for periodic cleaning of the energy  
recovery wheel will be a function of operating schedule, cli-  
mate and contaminants in the indoor air being exhausted, and  
the outdoor air being supplied to the building.  
The air exchange wheel is “self-cleaning” with respect to  
dry particles due to its laminar flow characteristics. Smaller  
particles pass through; larger particles land on the surface and  
are blown clear as the flow direction is reversed. Any material  
that builds up on the face of the wheel can be removed with a  
brush or vacuum. The primary need for cleaning is to remove  
oil-based aerosols that have condensed on energy transfer  
surfaces.  
NOTE: Some staining of the desiccant may remain and is not  
harmful to performance.  
Before removing, rapidly run finger across surface of wheel  
to separate polymer strips for better cleaning action. Rinse  
dirty solution from wheel and remove excess water before  
reinstalling.  
Do not use acid based cleaners, aromatic solvents, steam or  
temperatures in excess of 170 F; damage to the wheel may  
result.  
A characteristic of all dry desiccants, such films can close  
off micron sized pores at the surface of the desiccant material,  
reducing the efficiency by which the desiccant can adsorb and  
desorb moisture and also build up so as to reduce airflow.  
Air Seals — Diameter seals are provided on each cassette  
to minimize transfer of air between the counter flowing  
airstreams.  
In a reasonably clean indoor environment such as a school  
or office building, measurable reductions of airflow or loss of  
sensible effectiveness may not occur for several years. Measur-  
able changes in latent energy transfer can occur in shorter  
periods of time in applications such as moderate occupant  
smoking or cooking facilities. In applications experiencing  
unusually high levels of occupant smoking or oil-based aero-  
sols such as industrial applications involving the ventilation of  
machine shop areas for example, annual washing of energy  
transfer may be necessary to maintain latent transfer efficiency.  
Proper cleaning of the energy recovery wheel will restore latent  
effectiveness to near original performance.  
To adjust diameter seals, loosen diameter seal adjusting  
screws and back seals away from wheel surface (Fig. 92).  
Rotate wheel clockwise until two opposing spokes are hidden  
behind the bearing support beam. Using a folded piece of paper  
as a feeler gage, position paper between the wheel surface and  
diameter seals. Adjust seals towards wheel surface until a slight  
friction on the feeler gage (paper) is detected when gage is  
moved along the length of the spoke. Retighten adjusting  
screws and recheck clearance with “feeler” gage.  
78  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wheel Drive Components — The wheel drive motor  
bearings are pre-lubricated and no further lubrication is neces-  
sary. Make certain air cooling ports are not blocked.  
Rotation  
The wheel drive a pulley is secured to the drive motor shaft  
by a setscrew. The setscrew is secured with removable adhe-  
sive to prevent loosening. Annually confirm setscrew is secure.  
The wheel drive belt is a urethane stretch belt designed to  
provide constant tension through the life of the belt. No adjust-  
ment is required. Inspect the drive belt annually for proper  
tracking and tension. A properly tensioned belt will turn  
the wheel immediately after power is applied with no visible  
slippage during start-up.  
To  
Adjust  
Adjusting Screws  
Feeler Gage  
Fig. 92 — Diameter Seal Adjustment  
79  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Copyright 2006 Carrier Corporation  
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.  
Catalog No. 536-220 Printed in U.S.A. Form 62M-1SI Pg 80 1-06 Replaces: New  
Book 1  
4
Tab 10a 12a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.  

Black Box Computer Accessories IC64OA User Manual
Black Decker Automobile Accessories 90529232 User Manual
BlueAnt Wireless Bluetooth Headset Q2 User Manual
Blue Rhino Outdoor Fireplace WAD613T User Manual
Braun Electric Toothbrush D15525 User Manual
Breville Slow Cooker BSC500 User Manual
Brinkmann Gas Grill Heavy Duty Natural Gas Grill User Manual
Canon Camera Lens 15 85mm User Manual
Canon Printer 830D User Manual
CH Tech Projector Pulse Generator User Manual