Broan Ventilation Hood E60000 Series User Manual

INSTALLATION INSTRUCTIONS  
HB0073  
E60000 SERIES  
!
!
INTENDED FOR DOMESTIC COOKING ONLY  
READ AND SAVE THESE INSTRUCTIONS  
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.  
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 13 AND 14.  
Broan-NuTone LLC; Hartford, Wisconsin www.broan.com 800-558-1711  
Broan-NuTone Canada; Mississauga, Ontario www.broan.ca 877-896-1119  
REGISTER YOUR PRODUCT ON LINE AT: www.broan.com/register  
SV08340 rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- E60000 SERIES RANGE HOOD SYSTEM -  
INTERNAL BLOWERS  
MODEL 441  
MODEL 647  
MODEL 634 OR 644  
(ROOF CAP)  
MODEL 643  
(8” ROUND WALL CAP)  
MODEL 437  
(HIGH CAPACITY ROOF CAP)  
(10’’ ROUND WALL CAP)  
(7” ROUND WALL CAP)  
MODEL 418  
(10” ROUND  
ADJUSTABLE ELBOW)  
8” ROUND  
ADJUSTABLE  
MODEL 415  
7” ROUND ADJUSTABLE  
ELBOW  
MODEL 421  
(10” ROUND VERTICAL  
IN-LINE DAMPER)  
ELBOW  
MODEL 407  
(7” ROUND  
—2 FT. SECTIONS)  
8” ROUND  
STANDARD  
DUCT  
MODEL 410  
(10” ROUND DUCT  
—2 FT. SECTIONS)  
MODEL 412  
TRANSITION  
MODEL 413  
TRANSITION  
(3¼” X 10” TO 7”)  
(3¼” X 10” TO 8”)  
MODEL 639  
(3¼” X 10”  
WALL CAP)  
MODEL 427  
(4½” X 18½”  
TO 10” ROUND,  
6” HIGH - LATERAL  
MODEL 423  
(4½” X 18½”  
TO 10” ROUND -  
VERTICAL  
MODEL 424  
(4½” X 18½”  
TO 10” ROUND -  
HORIZ. FRONT/REAR  
MODEL 454  
(4½” X 18½”  
TO 10” ROUND -  
HORIZ. /RIGHT  
MODEL 453  
(4½” X 18½”  
TO 10” ROUND -  
HORIZ. /LEFT  
STANDARD  
DUCT  
(3¼” X 10”)  
OPTIONAL  
NON-DUCTED RECIRCULATION KIT  
ANKE60 SERIES  
OPTIONAL DECORATIVE  
FLUE AEE SERIES  
ADAPTER 4½” X 18½”  
(SUPPLIED WITH  
DOUBLE BLOWER HOOD)  
ADAPTER/DAMPER 3¼’’ X 10’’  
(SUPPLIED WITH  
SINGLE BLOWER HOOD)  
E60000 SERIES HOOD  
DUAL BLOWER (1200 CFM)  
42” AND 48” ONLY  
RMP SERIES  
SINGLE BLOWER (600 CFM)  
BACKSPLASH  
(STAINLESS STEEL WALL  
COVERING WITH WARMING  
SHELVES. OPTIONAL)  
HL0099  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- E60000 SERIES RANGE HOOD SYSTEM -  
IN-LINE AND EXTERIOR BLOWERS  
MODEL 441  
(10” ROUND WALL CAP)  
MODEL 437  
(HIGH CAPACITY ROOF CAP)  
MODEL HLB9 (800 CFM)  
OR HLB11 (1100 CFM)  
IN-LINE BLOWER  
MODEL 335 (1200 CFM)  
OR 336 (1500 CFM)  
EXTERIOR BLOWER  
MODEL 331H (600 CFM)  
OR 332H (900 CFM)  
EXTERIOR BLOWER  
(INCLUDES TWO 8” X 12” TO  
10’’ ROUND TRANSITIONS)  
MODEL 441  
(10” ROUND  
WALL CAP)  
MODEL 643  
(8” ROUND  
WALL CAP)  
MODEL HLB6 (600 CFM)  
IN-LINE BLOWER  
(INCLUDES TWO 4½” X 18½” TO  
10’’ ROUND TRANSITIONS)  
MODEL 421  
MODEL 418  
10” RD  
(10” RD. VERT.  
IN-LINE DAMPER)  
RECOMMENDED FOR  
USE WITH EXTERIOR  
BLOWERS  
ADJUSTABLE ELBOW  
MODEL HLB3 (280 CFM)  
IN-LINE BLOWER  
(INCLUDES ONE 8” TO 10”  
ROUND TRANSITION)  
MODEL 410  
(10” RD DUCT -  
2FT. SECTIONS)  
E60000 SERIES HOOD  
332KR IN-LINE AND  
EXTERIOR BLOWER ROUGH-IN KIT  
(SUPPLIED WITH HOOD)  
RMP SERIES BACKSPLASH  
(STAINLESS STEEL WALL COVERING  
WITH WARMING SHELVES.  
OPTIONAL)  
HL0100  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. SELECT BLOWER OPTION AND INSTALLATION TYPE  
1.1 NON-DUCTED INSTALLATION  
For a non-ducted installation, a recirculation kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness,  
we recommend installing this kit with a single (internal) blower hood. The kit fits hood from 30-inch width up to 48-inch  
width. See installation instructions included with the non-duct kit ANKE60 Series.  
1.2 DUCTED INSTALLATION  
The Broan Elite E60000 Series range hood includes many configurations: hoods with single or double internal blowers  
(included with the hood), or hoods using external blowers. For this last category, the Broan Elite E60000 Series must be  
installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only.  
Other blowers cannot be substituted. (Blowers sold separately).  
Plan where and how the ductwork will be installed.  
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 6, 10, 12 and  
up of this manual.  
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10”  
round ducts, use a transition (internal blowers only). Use 2” duct tape to seal duct joints.  
ROOF CAP  
ROOF CAP  
7or 8” ROUND  
OR 3¼x 10DUCT  
10ROUND DUCT  
DECORATIVE FLUE  
DECORATIVE FLUE  
12  
WALL CAP  
WALL CAP  
12”  
or SOFFIT  
or SOFFIT  
HOOD  
HOOD  
x 18½”  
TO 10”  
7or 8” ROUND  
OR 3¼x 10”  
RECTANGULAR  
ELBOW  
ROUND  
TRANSITION  
(see page 3)  
24TO 30ABOVE  
24TO 30ABOVE  
COOKING SURFACE  
COOKING SURFACE  
HH0088A  
HH0089A  
ONE INTERNAL BLOWER  
TYPICAL DUCTWORK  
TWO INTERNAL BLOWERS  
TYPICAL DUCTWORK  
EXTERIOR BLOWER  
ROOF CAP  
10ROUND  
DUCT  
10ROUND DUCT  
(except HLB3, 8’’ ROUND DUCT)  
IN-LINE BLOWER  
10ROUND  
ELBOW  
DECORATIVE FLUE  
12 ”  
OR SOFFIT  
EXTERIOR  
BLOWER  
WALL  
CAP  
HOOD  
332KR  
ROUGH-IN KIT  
(see page 4)  
HOOD  
24TO 30”  
ABOVE COOKING SURFACE  
24TO 30ABOVE  
COOKING SURFACE  
HH0090A  
HH0091A  
MODEL 331H, 332H, 335 OR 336  
EXTERIOR BLOWER TYPICAL DUCTWORK  
MODEL HLB3, HLB6, HLB9 OR HLB11  
IN-LINE BLOWER TYPICAL DUCTWORK  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. MEASURE INSTALLATION  
Dimensions for the most common installation are illustrated beside.  
Ceiling  
Top of wood  
mounting strip  
A + 2’’  
Cabinet, soffit,  
decorative flue or  
non-duct kit flue  
The minimum hood distance above cooktop must not be less  
than 24’’. A maximum of 30” above cooktop is highly  
recommended for best capture of cooking impurities.  
A
Distances over 30” are at the installer and users discretion.  
Hood  
Minimum distance between  
the hood and cooktop:  
24’’  
Recommended maximum  
distance between the hood  
and cooktop: 30’’  
Standard 36”  
high cooktop  
HH0093A  
MINIMUM AND MAXIMUM DISTANCE  
OVER COOKTOP  
3. PREPARE THE INSTALLATION  
CAUTION  
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and  
gloves.  
Remove the installation kit from inside the hood.  
Make sure that the following items are included:  
-Wood strip (attached to back of hood)  
-Installation manual  
-Accessories including:  
• Baffle filters: 30” and 36” hoods comes with 3 baffle filters; 42” and 48” hoods comes with 4 baffle filters  
• Baffle filters handles (taped inside the hood)  
• 3¼” x 10” adapter/damper (included with internal single blower hood)  
• 4½” x 18½” adapter (included with internal double blower hood)  
• In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)  
• Bag of parts including:  
(4) flat head screws no. 10-2’’, (8) screws no. 8 x 3/4’’, (2) wire connectors, (3) wall anchors,  
(3) washers 13/64’’ ID x 3/4’’ OD, (1) wire clamp, (8) mechanical screws no. 8-32 x 1/4”, (4) no. 8 x 3/8” screws  
Parts sold separately:  
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)  
- Exterior blower assembly 331H, 332H, 335 or 336  
- Shielded GU10 50W halogen bulbs (2 required for 30” and 36” hood width, 3 required for 42” and 48” hood width)  
- RMP Series Backsplash (optional)  
- ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)  
- AEE Series Decorative flue, to be installed over the hood (optional)  
- Transitions, duct, elbows, dampers, wall and roof caps.  
Refer to pages 3 and 4 for a complete list of venting options and model numbers.  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. PREPARE THE INSTALLATION (CONT’D)  
DUCTED INSTALLATIONS ONLY  
Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen.  
See figures below.  
NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter  
the discharge chosen (vertical or horizontal).  
INTERNAL DOUBLE BLOWER HOOD  
CABINET BOTTOM VIEW  
INTERNAL SINGLE BLOWER HOOD  
VERTICAL DISCHARGE  
CABINET BOTTOM VIEW  
HOOD  
WIDTHS  
C
C
L
L
DIMENSION C  
30’’  
36’’  
42’’  
48’’  
13”  
16”  
19”  
22”  
C
22”  
A
A
B
B
”  
3¾”  
2”  
2”  
10”  
10”  
”  
”  
2”  
2”  
1/2”  
7/8”  
INTERNAL SINGLE BLOWER HOOD  
INTERNAL DOUBLE BLOWER HOOD  
HORIZONTAL DISCHARGE  
HOOD  
WIDTHS  
DIMENSION C  
C
L
C
L
30’’  
36’’  
42’’  
48’’  
13”  
16”  
19”  
22”  
C
22”  
B
2”  
2”  
B
83  
8
91  
8
2”  
2”  
”  
A
3¾”  
10”  
10”  
”  
HD0266A  
HOOD WITH IN-LINE OR EXTERIOR BLOWER  
CABINET BOTTOM VIEW  
HOOD WITH IN-LINE OR EXTERIOR BLOWER  
3½”  
A
B
C
47  
8
L
C
L
10¼”  
³
8
57  
8
3½”  
Ø 10½”  
8  
B
A
8  
47  
8
”  
CABINET CENTER LINE  
Ø 10½”  
”  
HD0286A  
4. INSTALL BACKSPLASH (OPTIONAL)  
(Optional) RMP Series  
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order  
to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel  
or cooktop. (See instructions packed with backsplash.)  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY)  
Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.  
VERTICAL DISCHARGE  
1
1
2
2
3
3
HORIZONTAL DISCHARGE  
NOTE: For ducted installation only.  
HR0021  
A
B
Punch out the appropriate electrical knockout  
hole on top (A) or back (B) of the hood.  
Install the wire clamp (included in parts bag).  
NOTE: For a non-ducted installation, punch  
out the back electrical knock-out (B).  
HD0250  
6. REMOVE FILTERS AND THE GREASE DRIP RAIL  
A. Remove tape on filters.  
Remove filters from hood and set aside.  
NOTE: It is recommended to start with the  
center one.  
1
B. Remove tape on grease drip rail (1).  
Lift out grease drip rail and set aside.  
A
B
HD0243  
7. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)  
Remove the adapter (1), or adapter/damper, taped inside the hood.  
1
HD0287  
- 8 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) HOOD ONLY)  
All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal  
discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the inner back panel  
of the hood. The procedure below applies for one or two blowers.  
LEFT SIDE MOUNTING  
SCREW LOCATION  
Using a 5/16” socket, remove all  
blower mounting screws from the  
inner top of the hood. Keep the  
screws for further use.  
RIGHT SIDE  
MOUNTING SCREW  
LOCATION  
HD0282  
HD0269  
Slide the blower to disengage its flange from the  
retaining bracket.  
HD0270  
RIGHT SIDE  
MOUNTING SCREW  
LOCATION  
Rotate the blower and engage its  
flange in the back wall retaining  
bracket.  
LEFT SIDE MOUNTING  
SCREW LOCATION  
Using a 5/16” socket and the  
screws previously removed, secure  
the blower to the hood.  
HD0288  
HD0289  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)  
(INTERNAL BLOWER(S) HOOD ONLY)  
Using standard 3/8’’ screws provided, secure the adapter to the top (or back) of the hood (2 screws for a 3¼” x 10”  
adapter/damper and 4 screws for a 4½” x 18½” adapter). Seal the adapter to the hood using duct tape. For round ducting, install  
an appropriate sized transition and seal the joints with duct tape.  
HJ0013  
10. INSTALL WOOD MOUNTING STRIP  
Measure and mark a level line on wall above cooktop location for the wood  
mounting strip (see illustration beside and under step 2). Remove wood mounting  
strip from back of hood.  
Use no. 10 - 2’’ flat head screws to secure the mounting strip to the drywall. Make  
sure to hit the wall studs.  
CAUTION  
Due to the weight of this hood, ensure that the wood strip is  
attached to all of the available studs (2 studs minimum for a 30’’  
width hood, more as hood width increases); not into the drywall  
alone.  
HD0263A  
1. Drywall  
2. Wood mounting strip  
3. Flat head screw  
4. Wall anchor location  
5. Back of hood outline  
6. Wall studs  
11. INSTALL ANKE60 RECIRCULATION KIT (NON-DUCTED INSTALLATION ONLY)  
Refer to the instructions sheet included with the recirculation kit for details.  
12. INSTALL AEE OPTIONAL SOFFIT CHIMNEY  
(DUCTED INSTALLATION ONLY)  
Refer to the instructions sheet included with the optional soffit chimney.  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. INSTALL THE HOOD  
CAUTION  
Hold the hood until it is completely secured to the wood  
mounting strip.  
MOUNTING SCREWS LOCATION  
WALL ANCHORS LOCATION  
INTERNAL BLOWER(S) ONLY  
Run power cable to installation location. Remove the electrical compartment cover.  
Insert the cable in the hood and tighten the wire clamp to secure the cable.  
ALL INSTALLATIONS  
HD0264  
Rest the back cavity of the hood on the wood mounting strip.  
Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4’’ (for 30’’ and  
36’’ width hoods) or (6) screws (for 42’’ and 48’’ width hoods) provided at locations shown. Drill (3) 3/16’’ size holes into the  
drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the three wall  
anchors with the remaining no. 8 x 3/4’’ screws and the (3) washers provided.  
For a non-ducted installation, go to step 15, Connect the wiring.  
14. ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY)  
Run power cable to installation location. For ducting through top of hood, existing  
plate remains in place on inside back of hood.  
ROUGH-IN PLATE  
ON TOP OF HOOD  
For ducting through back of hood, remove existing plate from inside back of hood  
and remove the rough-in plate from the top of hood. Attach the plate to inside top  
of hood to cover hole. Secure to threaded studs with same (4) nuts. Install the  
rough-in plate to the back of hood so that the wiring box is located on the right  
side as you are facing the hood.  
WIRING  
COVER  
LOCKNUTS  
LOCKNUTS  
Connect ducting to rough-in plate as you are installing the rough-in plate. Use  
duct tape to make all joints secure and air-tight.  
HD0262  
PLATE ON BACK OF HOOD  
15. CONNECT THE WIRING (ALL BLOWERS)  
WARNING  
!
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all  
applicable codes and standards. Before connecting wires, switch power off at service panel and lock  
service disconnecting means to prevent power to be switched on accidentally.  
Remove wiring cover from rough-in plate or electrical compartment and set aside.  
INTERNAL BLOWERS: Connect cable into wiring box using wire connectors.  
Connect BLACK to BLACK, WHITE to WHITE and  
GREEN or bare wire under GREEN ground screw.  
A
CAUTION  
The ORANGE wire (A) is for make-up air device connection only.  
If there is no make-up air device, never remove the cap on the  
ORANGE wire end.  
Reinstall wiring cover.  
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.  
HE0088  
- 11 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER)  
Refer to instructions included with blower.  
Plug the 3-prong plug cord from rough-in plate to the 3-prong male  
connector inside the hood (A) and the 2-prong male connector cord from rough-in  
plate to the 2-prong plug inside the hood (B).  
B
A
WARNING  
!
Do not plug the 2 cords together.  
HE0078  
17. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS  
Reinstall grease drip rail.The illustration beside shows how to reinsert the grease  
drip rail into the range hood.  
HD0244  
CAUTION  
Remove protective plastic film covering filters before installing them.  
NOTE:Assemble the metal handles  
to the filters, using provided  
1
2
no. 8-32 x 1/4” screws, before  
installing them in the hood.  
It is recommended to install side  
filters first and finish with center one(s).  
1. Insert one end of the filter into the  
upper channel of the hood.  
2. Raise the other end toward the  
inside of hood and insert in the  
grease drip rail of the hood.  
HD0245  
18. INSTALL LIGHT BULBS  
WARNING  
!
1
2
In order to prevent the risk of personal injury, do not install a  
lamp identified for use only in enclosed fixtures.  
This hood must use 50W, 120V with GU10 base, shielded halogen bulbs (not  
included). (2 required for 30” and 36” hood width or 3 for 42” and 48” hood width.)  
1. Install bulbs by placing the bulb leads into their grooves in the socket.  
2. Gently push upwards and turn clockwise until secure.  
HO0090  
WARNING  
!
In order to prevent the risk of personal injury, the halogen bulbs must be cooled down before removing  
them.  
To remove bulbs, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.  
NOTE: If need be, use a rubber dishwashing glove to add grip when removing the bulb.  
- 12 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19. USE AND CARE  
Baffle Filters  
The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates  
greater grease—like frying foods or wok cooking.  
Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe.  
Allow filters to dry completely before reinstalling them in the hood.  
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate  
detergent or as a result of local water conditions—but this will not affect filter performance. This discoloration is not covered by  
the warranty.  
Grease Drip Rail  
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle  
filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail  
to dry completely before reinstalling it in the hood.  
Blower Cleaning (Internal)  
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water.  
Hood Cleaning  
Stainless steel cleaning:  
Do:  
Don’t:  
• Regularly wash with clean cloth or rag soaked with warm • Use any steel or stainless steel wool or any other scrapers  
water and mild soap or liquid dish detergent.  
• Always clean in the direction of original polish lines.  
• Always rinse well with clear water (2 or 3 times) after  
cleaning. Wipe dry completely.  
You may also use a specialized household stainless steel  
cleaner.  
to remove stubborn dirt.  
• Use any harsh or abrasive cleansers.  
• Allow dirt to accumulate.  
• Let plaster dust or any other construction residues reach  
the hood. During construction/renovation, cover the hood  
to make sure no dust sticks to stainless steel surface.  
Avoid: When choosing a detergent  
• Any cleaners that contain bleach will attack stainless steel.  
• Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.  
• Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should  
never be used close to a range.  
20. OPERATION  
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes  
to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.  
HEAT SENTRY  
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower if it  
senses excessive heat above the cooking surface.  
1) If blower is OFF - it turns blower ON to HIGH speed.  
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.  
WARNING  
!
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible to turn  
the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel.  
When the temperature level drops to normal, the blower will return to its original setting.  
- 13 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20. OPERATION (CONT’D)  
4
3
2
1
A
B
HC0034  
A) Halogen light knob  
B) Blower speed control knob  
HC0035  
1) Halogen light knob  
2) Blower operation indicator  
3) ON/OFF blower switch  
4) Blower speed control knob  
COOKTOP LIGHTING (HALOGEN)  
A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity).  
BLOWER  
The blower is operated using two controls.  
Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the blower  
operates at the previous setting of the speed control (4).  
Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.  
21. WARRANTY  
WARRANTY  
BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY  
Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in  
materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER  
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  
During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which  
is found to be defective under normal use and service.  
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to  
misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or  
installation contrary to recommended installation instructions.  
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or  
provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.  
BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE  
PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE  
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH  
PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental  
or consequential damages, so the above limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to  
another. This warranty supersedes all prior warranties.  
To qualify for warranty service, you must (a) notify Broan-NuTone LLC at one of the addresses or telephone number stated  
below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At  
the time of requesting warranty service, you must present evidence of the original purchase date.  
(For U.S.) Broan-NuTone LLC; 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711  
(For Canada) Broan-NuTone Canada; 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 877-896-1119  
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22. WIRING DIAGRAMS  
Broan Elite E60000 Series  
Internal blower(s) hoods  
NEON  
BLK  
FAN  
SWITCH  
On 3  
SPEED  
CONTROL  
1
BLK  
BRN  
BLU  
Off 2  
ORA  
USE ONLY WITH  
APPROPRIATE  
MAKE-UP AIR SYSTEM  
M
M
BLK  
ORA  
RED  
BLK  
WHT  
ORA  
HS  
THERMOSTAT  
BLU  
LINE  
NEUTRAL  
GROUND  
BLK  
BLU  
WHT  
BRN  
BLU  
WHT  
WHT  
BLK  
BLK  
LAMP  
SWITCH  
RED  
BLK  
YEL  
YEL  
L
1-3  
YEL  
2
WHT  
WHT  
WHT  
COLOR CODE  
BLK  
BLACK  
BLUE  
BROWN  
ORANGE  
RED  
WHITE  
YELLOW  
BLU  
BRN  
ORA  
RED  
WHT  
YEL  
LAMP  
LAMP  
LAMP  
HE0090A  
Broan Elite E60000 Series  
NEON  
BLK  
SPEED CONTROL  
Exterior or In-Line blower hoods  
FAN  
SWITCH  
On 3  
COLOR CODE  
1
BLK  
BLU  
GRN  
ORA  
WHT  
YEL  
BLACK  
BLUE  
GREEN  
ORANGE  
WHITE  
YELLOW  
BLK  
Off 2  
ORA  
USE ONLY WITH  
APPROPRIATE  
MAKE-UP AIR SYSTEM  
ORA  
HS  
THERMOSTAT  
BLK  
BLU  
BLK  
BLU  
WHT  
WHT  
BLK  
LAMP  
SWITCH  
YEL  
BLK  
BLK  
YEL  
WHT  
L
1-3  
2
YEL  
WHT  
WHT  
WHT  
GRN  
WHT  
120 V  
SUPPLY  
LINE  
M
BLK  
BLK  
RETURN  
GROUND  
WHT  
WHT  
GRN  
LAMP  
LAMP  
LAMP  
REMOTE  
BLOWER ASSEMBLY  
ROUGH-IN PLATE  
HE0091A  
WHT  
- 15 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23. SERVICE PARTS  
Broan Elite E60000 Series  
Internal blower hoods  
Broan Elite E60000 Series  
Exterior or In-Line blower hoods  
1
15  
15  
2
2
3
6
5
14  
14  
3
6
7
5
18  
17  
4
7
4
10  
9
16  
8
11  
12  
11  
13  
13  
12  
HL0105  
HL0106  
KEY PART  
DESCRIPTION  
QTY. (HOOD WIDTH)  
30” 36” 42” 48”  
KEY PART  
NO. NO.  
2 SV06750 BROAN ELITE LOGO  
3 SV16569 LAMP SHELL, SOCKET & TRIM ASSY  
4 SV03435 HEAT SENTRY THERMOSTAT  
5 SV08338 LIGHT SWITCH  
6 SV03501 SPEED CONTROL  
7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)  
SV17640 GREASE RAIL 30”  
DESCRIPTION  
QTY. (HOOD WIDTH)  
30” 36” 42” 48”  
NO.  
NO.  
ADAPTER/DAMPER 3¼” X 10”  
(1-BLOWER HOOD)  
1
2
1
1
1
1
1
-
1
2
1
1
1
1
-
1
-
-
1
3
1
1
1
1
-
-
1
-
1
2
2
1
1
1
1
1
1
1
3
1
1
1
1
-
SV13296  
1
1
1
1
1
SV17797 ADAPTER 4½” X 18½” (2-BLOWER HOOD)  
2 SV06750 BROAN ELITE LOGO  
3 SV16569 LAMP SHELL, SOCKET & TRIM ASSY  
4 SV03435 HEAT SENTRY THERMOSTAT  
5 SV08338 LIGHT SWITCH  
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
6 SV03501 SPEED CONTROL  
SV17641 GREASE RAIL 36”  
SV17642 GREASE RAIL 42”  
-
-
11  
7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)  
8 SV08343 REPLACEMENT CHARCOAL FILTERS (PAIR)  
9 SV08344 CHARCOAL FILTER SUPPORTS (PAIR)  
-
-
SV17643 GREASE RAIL 48”  
12 SV08337 FILTER SPRINGS (4)  
1
1
-
4
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
-
INTERNAL MOTOR  
(1 OR 2, DEPENDING ON HOOD MODEL)  
SV17606 BAFFLE FILTER 8.84” X 15.125”  
SV17609 BAFFLE FILTER 11.84” X 15.125”  
10 SV08097  
1
1
1
1
13  
3
1
1
1
1
1
1
SV17640 GREASE RAIL 30”  
1
-
-
-
1
-
-
1
-
3
1
1
1
-
-
1
-
1
2
2
1
1
1
-
-
-
14 SV08339 BLOWER ROCKER SWITCH  
15 SV08093 PILOT LAMP ASSY  
16 SV08354 ROUGH-IN PLATE 10” ROUND  
17 SV13924 FEMALE CONNECTOR  
18 SV13923 MALE CONNECTOR  
SV17641 GREASE RAIL 36”  
SV17642 GREASE RAIL 42”  
11  
SV17643 GREASE RAIL 48”  
12 SV08337 FILTER SPRINGS (4)  
-
1
1
-
4
1
1
1
1
2
1
1
1
1
SV17606 BAFFLE FILTER 8.84” X 15.125”  
SV17609 BAFFLE FILTER 11.84” X 15.125”  
13  
*
SV08340 INSTALLATION GUIDE  
PARTS BAG ([2] WIRE CONNECTORS,  
[9] SCREWS NO. 8 X 1/2”,  
14 SV08339 BLOWER ROCKER SWITCH  
15 SV08093 PILOT LAMP ASSY  
[1] WIRE CLAMP, [3] WALL ANCHORS,  
[3] WASHERS 13/64’’ ID x 3/4’’ OD,  
[4] SCREWS NO. 8 X 3/8”)  
*
SV08340 INSTALLATION GUIDE  
*
SV08352  
1
1
1
1
PARTS BAG ([2] WIRE CONNECTORS,  
[9] SCREWS NO. 8 X 1/2”,  
[1] WIRE CLAMP, [3] WALL ANCHORS,  
[3] WASHERS 13/64’’ ID x 3/4’’ OD,  
[4] SCREWS NO. 8 X 3/8”)  
[8] SCREWS NO. 8 X 3/4”,  
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,  
[4] FLAT HEAD SCREWS NO. 10-2”)  
*
SV08352  
1
1
1
1
* NOT SHOWN.  
[8] SCREWS NO. 8 X 3/4”,  
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,  
[4] FLAT HEAD SCREWS NO. 10-2”)  
* NOT SHOWN.  
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Beko Washer Dryer WMG 10454 W User Manual
Beko Washer WCY 71232 HPTL User Manual
Bertazzoni Range H304GGVCR User Manual
Black Decker Food Processor HC20 User Manual
Blanco Indoor Furnishings 515 546 User Manual
Bogen Speaker System AE SB User Manual
Canon Camcorder ZR25 MC User Manual
Canon Scanner D1230U D2400U User Manual
Carrier Smoke Alarm 48 50HG014 028 User Manual
CBC VCR CTR 030NC 2 User Manual