INSTALLATION INSTRUCTIONS
HB0073
E60000 SERIES
!
!
INTENDED FOR DOMESTIC COOKING ONLY
READ AND SAVE THESE INSTRUCTIONS
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGE 13 AND 14.
SV08340 rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
- E60000 SERIES RANGE HOOD SYSTEM -
INTERNAL BLOWERS
MODEL 441
MODEL 647
MODEL 634 OR 644
(ROOF CAP)
MODEL 643
(8” ROUND WALL CAP)
MODEL 437
(HIGH CAPACITY ROOF CAP)
(10’’ ROUND WALL CAP)
(7” ROUND WALL CAP)
MODEL 418
(10” ROUND
ADJUSTABLE ELBOW)
8” ROUND
ADJUSTABLE
MODEL 415
7” ROUND ADJUSTABLE
ELBOW
MODEL 421
(10” ROUND VERTICAL
IN-LINE DAMPER)
ELBOW
MODEL 407
(7” ROUND
—2 FT. SECTIONS)
8” ROUND
STANDARD
DUCT
MODEL 410
(10” ROUND DUCT
—2 FT. SECTIONS)
MODEL 412
TRANSITION
MODEL 413
TRANSITION
(3¼” X 10” TO 7”)
(3¼” X 10” TO 8”)
MODEL 639
(3¼” X 10”
WALL CAP)
MODEL 427
(4½” X 18½”
TO 10” ROUND,
6” HIGH - LATERAL
MODEL 423
(4½” X 18½”
TO 10” ROUND -
VERTICAL
MODEL 424
(4½” X 18½”
TO 10” ROUND -
HORIZ. FRONT/REAR
MODEL 454
(4½” X 18½”
TO 10” ROUND -
HORIZ. /RIGHT
MODEL 453
(4½” X 18½”
TO 10” ROUND -
HORIZ. /LEFT
STANDARD
DUCT
(3¼” X 10”)
OPTIONAL
NON-DUCTED RECIRCULATION KIT
ANKE60 SERIES
OPTIONAL DECORATIVE
FLUE AEE SERIES
ADAPTER 4½” X 18½”
(SUPPLIED WITH
DOUBLE BLOWER HOOD)
ADAPTER/DAMPER 3¼’’ X 10’’
(SUPPLIED WITH
SINGLE BLOWER HOOD)
E60000 SERIES HOOD
DUAL BLOWER (1200 CFM)
42” AND 48” ONLY
RMP SERIES
SINGLE BLOWER (600 CFM)
BACKSPLASH
(STAINLESS STEEL WALL
COVERING WITH WARMING
SHELVES. OPTIONAL)
HL0099
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
- E60000 SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
MODEL 441
(10” ROUND WALL CAP)
MODEL 437
(HIGH CAPACITY ROOF CAP)
MODEL HLB9 (800 CFM)
OR HLB11 (1100 CFM)
IN-LINE BLOWER
MODEL 335 (1200 CFM)
OR 336 (1500 CFM)
EXTERIOR BLOWER
MODEL 331H (600 CFM)
OR 332H (900 CFM)
EXTERIOR BLOWER
(INCLUDES TWO 8” X 12” TO
10’’ ROUND TRANSITIONS)
MODEL 441
(10” ROUND
WALL CAP)
MODEL 643
(8” ROUND
WALL CAP)
MODEL HLB6 (600 CFM)
IN-LINE BLOWER
(INCLUDES TWO 4½” X 18½” TO
10’’ ROUND TRANSITIONS)
MODEL 421
MODEL 418
10” RD
(10” RD. VERT.
IN-LINE DAMPER)
RECOMMENDED FOR
USE WITH EXTERIOR
BLOWERS
ADJUSTABLE ELBOW
MODEL HLB3 (280 CFM)
IN-LINE BLOWER
(INCLUDES ONE 8” TO 10”
ROUND TRANSITION)
MODEL 410
(10” RD DUCT -
2FT. SECTIONS)
E60000 SERIES HOOD
332KR IN-LINE AND
EXTERIOR BLOWER ROUGH-IN KIT
(SUPPLIED WITH HOOD)
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES.
OPTIONAL)
HL0100
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
1. SELECT BLOWER OPTION AND INSTALLATION TYPE
1.1 NON-DUCTED INSTALLATION
For a non-ducted installation, a recirculation kit ANKE60 Series (sold separately) must be installed. For maximum effectiveness,
we recommend installing this kit with a single (internal) blower hood. The kit fits hood from 30-inch width up to 48-inch
width. See installation instructions included with the non-duct kit ANKE60 Series.
1.2 DUCTED INSTALLATION
The Broan Elite E60000 Series range hood includes many configurations: hoods with single or double internal blowers
(included with the hood), or hoods using external blowers. For this last category, the Broan Elite E60000 Series must be
installed with in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only.
Other blowers cannot be substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 6, 10, 12 and
up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7”, 8” or 10”
round ducts, use a transition (internal blowers only). Use 2” duct tape to seal duct joints.
ROOF CAP
ROOF CAP
7” or 8” ROUND
OR 3¼” x 10” DUCT
10” ROUND DUCT
DECORATIVE FLUE
DECORATIVE FLUE
12”
WALL CAP
WALL CAP
12”
or SOFFIT
or SOFFIT
HOOD
HOOD
4½” x 18½”
TO 10”
7” or 8” ROUND
OR 3¼” x 10”
RECTANGULAR
ELBOW
ROUND
TRANSITION
(see page 3)
24” TO 30” ABOVE
24” TO 30” ABOVE
COOKING SURFACE
COOKING SURFACE
HH0088A
HH0089A
ONE INTERNAL BLOWER
TYPICAL DUCTWORK
TWO INTERNAL BLOWERS
TYPICAL DUCTWORK
EXTERIOR BLOWER
ROOF CAP
10” ROUND
DUCT
10” ROUND DUCT
(except HLB3, 8’’ ROUND DUCT)
IN-LINE BLOWER
10” ROUND
ELBOW
DECORATIVE FLUE
12 ”
OR SOFFIT
EXTERIOR
BLOWER
WALL
CAP
HOOD
332KR
ROUGH-IN KIT
(see page 4)
HOOD
24” TO 30”
ABOVE COOKING SURFACE
24” TO 30” ABOVE
COOKING SURFACE
HH0090A
HH0091A
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER TYPICAL DUCTWORK
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
2. MEASURE INSTALLATION
Dimensions for the most common installation are illustrated beside.
Ceiling
Top of wood
mounting strip
A + 2’’
Cabinet, soffit,
decorative flue or
non-duct kit flue
The minimum hood distance above cooktop must not be less
than 24’’. A maximum of 30” above cooktop is highly
recommended for best capture of cooking impurities.
A
Distances over 30” are at the installer and users discretion.
Hood
Minimum distance between
the hood and cooktop:
24’’
Recommended maximum
distance between the hood
and cooktop: 30’’
Standard 36”
high cooktop
HH0093A
MINIMUM AND MAXIMUM DISTANCE
OVER COOKTOP
3. PREPARE THE INSTALLATION
CAUTION
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and
gloves.
Remove the installation kit from inside the hood.
Make sure that the following items are included:
-Wood strip (attached to back of hood)
-Installation manual
-Accessories including:
• Baffle filters: 30” and 36” hoods comes with 3 baffle filters; 42” and 48” hoods comes with 4 baffle filters
• Baffle filters handles (taped inside the hood)
• 3¼” x 10” adapter/damper (included with internal single blower hood)
• 4½” x 18½” adapter (included with internal double blower hood)
• In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
• Bag of parts including:
(4) flat head screws no. 10-2’’, (8) screws no. 8 x 3/4’’, (2) wire connectors, (3) wall anchors,
(3) washers 13/64’’ ID x 3/4’’ OD, (1) wire clamp, (8) mechanical screws no. 8-32 x 1/4”, (4) no. 8 x 3/8” screws
Parts sold separately:
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- Exterior blower assembly 331H, 332H, 335 or 336
- Shielded GU10 50W halogen bulbs (2 required for 30” and 36” hood width, 3 required for 42” and 48” hood width)
- RMP Series Backsplash (optional)
- ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)
- AEE Series Decorative flue, to be installed over the hood (optional)
- Transitions, duct, elbows, dampers, wall and roof caps.
Refer to pages 3 and 4 for a complete list of venting options and model numbers.
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
3. PREPARE THE INSTALLATION (CONT’D)
DUCTED INSTALLATIONS ONLY
Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen.
See figures below.
NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter
the discharge chosen (vertical or horizontal).
INTERNAL DOUBLE BLOWER HOOD
CABINET BOTTOM VIEW
INTERNAL SINGLE BLOWER HOOD
VERTICAL DISCHARGE
CABINET BOTTOM VIEW
HOOD
WIDTHS
C
C
L
L
DIMENSION C
30’’
36’’
42’’
48’’
13”
16”
19”
22”
C
22”
A
A
B
B
5½”
3¾”
2”
2”
10”
10”
5¼”
5¼”
2”
2”
1/2”
7/8”
INTERNAL SINGLE BLOWER HOOD
INTERNAL DOUBLE BLOWER HOOD
HORIZONTAL DISCHARGE
HOOD
WIDTHS
DIMENSION C
C
L
C
L
30’’
36’’
42’’
48’’
13”
16”
19”
22”
C
22”
B
2”
2”
B
83
8
”
91
8
”
2”
2”
5½”
A
3¾”
10”
10”
5¼” 5¼”
HD0266A
HOOD WITH IN-LINE OR EXTERIOR BLOWER
CABINET BOTTOM VIEW
HOOD WITH IN-LINE OR EXTERIOR BLOWER
3½”
A
B
C
47
8
”
L
C
L
10¼”
³
8
”
57
8
”
3½”
Ø 10½”
5³8
”
B
A
9³8
”
47
8
”
9¾”
CABINET CENTER LINE
Ø 10½”
9¾”
HD0286A
4. INSTALL BACKSPLASH (OPTIONAL)
(Optional) RMP Series
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order
to be able to install the backsplash, make sure you have at least 18’’ clearance between bottom of hood and range control panel
or cooktop. (See instructions packed with backsplash.)
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
5. CHOOSE THE OPENING(S) (INTERNAL BLOWER(S) HOOD ONLY)
Remove the knockout(s) for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.
VERTICAL DISCHARGE
1
1
2
2
3
3
HORIZONTAL DISCHARGE
NOTE: For ducted installation only.
HR0021
A
B
Punch out the appropriate electrical knockout
hole on top (A) or back (B) of the hood.
Install the wire clamp (included in parts bag).
NOTE: For a non-ducted installation, punch
out the back electrical knock-out (B).
HD0250
6. REMOVE FILTERS AND THE GREASE DRIP RAIL
A. Remove tape on filters.
Remove filters from hood and set aside.
NOTE: It is recommended to start with the
center one.
1
B. Remove tape on grease drip rail (1).
Lift out grease drip rail and set aside.
A
B
HD0243
7. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)
Remove the adapter (1), or adapter/damper, taped inside the hood.
1
HD0287
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
8. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) HOOD ONLY)
All internal blower hoods are factory shipped with the blowers mounted for a vertical discharge configuration. For a horizontal
discharge configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the inner back panel
of the hood. The procedure below applies for one or two blowers.
LEFT SIDE MOUNTING
SCREW LOCATION
Using a 5/16” socket, remove all
blower mounting screws from the
inner top of the hood. Keep the
screws for further use.
RIGHT SIDE
MOUNTING SCREW
LOCATION
HD0282
HD0269
Slide the blower to disengage its flange from the
retaining bracket.
HD0270
RIGHT SIDE
MOUNTING SCREW
LOCATION
Rotate the blower and engage its
flange in the back wall retaining
bracket.
LEFT SIDE MOUNTING
SCREW LOCATION
Using a 5/16” socket and the
screws previously removed, secure
the blower to the hood.
HD0288
HD0289
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
9. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)
(INTERNAL BLOWER(S) HOOD ONLY)
Using standard 3/8’’ screws provided, secure the adapter to the top (or back) of the hood (2 screws for a 3¼” x 10”
adapter/damper and 4 screws for a 4½” x 18½” adapter). Seal the adapter to the hood using duct tape. For round ducting, install
an appropriate sized transition and seal the joints with duct tape.
HJ0013
10. INSTALL WOOD MOUNTING STRIP
Measure and mark a level line on wall above cooktop location for the wood
mounting strip (see illustration beside and under step 2). Remove wood mounting
strip from back of hood.
Use no. 10 - 2’’ flat head screws to secure the mounting strip to the drywall. Make
sure to hit the wall studs.
CAUTION
Due to the weight of this hood, ensure that the wood strip is
attached to all of the available studs (2 studs minimum for a 30’’
width hood, more as hood width increases); not into the drywall
alone.
HD0263A
1. Drywall
2. Wood mounting strip
3. Flat head screw
4. Wall anchor location
5. Back of hood outline
6. Wall studs
11. INSTALL ANKE60 RECIRCULATION KIT (NON-DUCTED INSTALLATION ONLY)
Refer to the instructions sheet included with the recirculation kit for details.
12. INSTALL AEE OPTIONAL SOFFIT CHIMNEY
(DUCTED INSTALLATION ONLY)
Refer to the instructions sheet included with the optional soffit chimney.
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
13. INSTALL THE HOOD
CAUTION
Hold the hood until it is completely secured to the wood
mounting strip.
MOUNTING SCREWS LOCATION
WALL ANCHORS LOCATION
INTERNAL BLOWER(S) ONLY
Run power cable to installation location. Remove the electrical compartment cover.
Insert the cable in the hood and tighten the wire clamp to secure the cable.
ALL INSTALLATIONS
HD0264
Rest the back cavity of the hood on the wood mounting strip.
Secure the hood to wood mounting strip with (4) screws no. 8 x 3/4’’ (for 30’’ and
36’’ width hoods) or (6) screws (for 42’’ and 48’’ width hoods) provided at locations shown. Drill (3) 3/16’’ size holes into the
drywall for wall anchors through the existing holes in the inside hood back in the locations shown. Then, install the three wall
anchors with the remaining no. 8 x 3/4’’ screws and the (3) washers provided.
For a non-ducted installation, go to step 15, Connect the wiring.
14. ROUGH-IN PLATE LOCATION (EXTERNAL BLOWERS HOODS ONLY)
Run power cable to installation location. For ducting through top of hood, existing
plate remains in place on inside back of hood.
ROUGH-IN PLATE
ON TOP OF HOOD
For ducting through back of hood, remove existing plate from inside back of hood
and remove the rough-in plate from the top of hood. Attach the plate to inside top
of hood to cover hole. Secure to threaded studs with same (4) nuts. Install the
rough-in plate to the back of hood so that the wiring box is located on the right
side as you are facing the hood.
WIRING
COVER
LOCKNUTS
LOCKNUTS
Connect ducting to rough-in plate as you are installing the rough-in plate. Use
duct tape to make all joints secure and air-tight.
HD0262
PLATE ON BACK OF HOOD
15. CONNECT THE WIRING (ALL BLOWERS)
WARNING
!
Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power to be switched on accidentally.
Remove wiring cover from rough-in plate or electrical compartment and set aside.
INTERNAL BLOWERS: Connect cable into wiring box using wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under GREEN ground screw.
A
CAUTION
The ORANGE wire (A) is for make-up air device connection only.
If there is no make-up air device, never remove the cap on the
ORANGE wire end.
Reinstall wiring cover.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
HE0088
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
16. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER)
Refer to instructions included with blower.
Plug the 3-prong plug cord from rough-in plate to the 3-prong male
connector inside the hood (A) and the 2-prong male connector cord from rough-in
plate to the 2-prong plug inside the hood (B).
B
A
WARNING
!
Do not plug the 2 cords together.
HE0078
17. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS
Reinstall grease drip rail.The illustration beside shows how to reinsert the grease
drip rail into the range hood.
HD0244
CAUTION
Remove protective plastic film covering filters before installing them.
NOTE:Assemble the metal handles
to the filters, using provided
1
2
no. 8-32 x 1/4” screws, before
installing them in the hood.
It is recommended to install side
filters first and finish with center one(s).
1. Insert one end of the filter into the
upper channel of the hood.
2. Raise the other end toward the
inside of hood and insert in the
grease drip rail of the hood.
HD0245
18. INSTALL LIGHT BULBS
WARNING
!
1
2
In order to prevent the risk of personal injury, do not install a
lamp identified for use only in enclosed fixtures.
This hood must use 50W, 120V with GU10 base, shielded halogen bulbs (not
included). (2 required for 30” and 36” hood width or 3 for 42” and 48” hood width.)
1. Install bulbs by placing the bulb leads into their grooves in the socket.
2. Gently push upwards and turn clockwise until secure.
HO0090
WARNING
!
In order to prevent the risk of personal injury, the halogen bulbs must be cooled down before removing
them.
To remove bulbs, gently push upwards and turn counterclockwise to disengage bulb leads from their grooves.
NOTE: If need be, use a rubber dishwashing glove to add grip when removing the bulb.
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
19. USE AND CARE
Baffle Filters
The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style generates
greater grease—like frying foods or wok cooking.
Remove baffle filters by pushing them towards the back of hood and rotating filters downward. Baffle filters are dishwasher safe.
Allow filters to dry completely before reinstalling them in the hood.
Clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate
detergent or as a result of local water conditions—but this will not affect filter performance. This discoloration is not covered by
the warranty.
Grease Drip Rail
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle
filters, wash more often if your cooking style generates greater grease—like frying foods or wok cooking. Allow grease drip rail
to dry completely before reinstalling it in the hood.
Blower Cleaning (Internal)
Remove the filters in order to access the blower. Vacuum blower to clean. Do not immerse in water.
Hood Cleaning
Stainless steel cleaning:
Do:
Don’t:
• Regularly wash with clean cloth or rag soaked with warm • Use any steel or stainless steel wool or any other scrapers
water and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after
cleaning. Wipe dry completely.
• You may also use a specialized household stainless steel
cleaner.
to remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach
the hood. During construction/renovation, cover the hood
to make sure no dust sticks to stainless steel surface.
Avoid: When choosing a detergent
• Any cleaners that contain bleach will attack stainless steel.
• Any products containing: chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should
never be used close to a range.
20. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes
to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
HEAT SENTRY
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower if it
senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
WARNING
!
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible to turn
the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel.
When the temperature level drops to normal, the blower will return to its original setting.
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
20. OPERATION (CONT’D)
4
3
2
1
A
B
HC0034
A) Halogen light knob
B) Blower speed control knob
HC0035
1) Halogen light knob
2) Blower operation indicator
3) ON/OFF blower switch
4) Blower speed control knob
COOKTOP LIGHTING (HALOGEN)
A rotary 3-position knob (1) controls the halogen lights (OFF - low intensity - high intensity).
BLOWER
The blower is operated using two controls.
Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the blower
operates at the previous setting of the speed control (4).
Turn the speed control knob counterclockwise to increase blower speed – clockwise to decrease speed.
21. WARRANTY
WARRANTY
BROAN-NUTONE LLC ONE-YEAR LIMITED WARRANTY
Broan-NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in
materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which
is found to be defective under normal use and service.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to
misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone LLC), faulty installation or
installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states or
provinces do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE LLC’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE LLC’S OPTION, SHALL BE THE
PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE LLC SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states or provinces do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state or province to
another. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone LLC at one of the addresses or telephone number stated
below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the original purchase date.
(For U.S.) Broan-NuTone LLC; 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711
(For Canada) Broan-NuTone Canada; 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 877-896-1119
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
22. WIRING DIAGRAMS
Broan Elite E60000 Series
Internal blower(s) hoods
NEON
BLK
FAN
SWITCH
On 3
SPEED
CONTROL
1
BLK
BRN
BLU
Off 2
ORA
USE ONLY WITH
APPROPRIATE
MAKE-UP AIR SYSTEM
M
M
BLK
ORA
RED
BLK
WHT
ORA
HS
THERMOSTAT
BLU
LINE
NEUTRAL
GROUND
BLK
BLU
WHT
BRN
BLU
WHT
WHT
BLK
BLK
LAMP
SWITCH
RED
BLK
YEL
YEL
L
1-3
YEL
2
WHT
WHT
WHT
COLOR CODE
BLK
BLACK
BLUE
BROWN
ORANGE
RED
WHITE
YELLOW
BLU
BRN
ORA
RED
WHT
YEL
LAMP
LAMP
LAMP
HE0090A
Broan Elite E60000 Series
NEON
BLK
SPEED CONTROL
Exterior or In-Line blower hoods
FAN
SWITCH
On 3
COLOR CODE
1
BLK
BLU
GRN
ORA
WHT
YEL
BLACK
BLUE
GREEN
ORANGE
WHITE
YELLOW
BLK
Off 2
ORA
USE ONLY WITH
APPROPRIATE
MAKE-UP AIR SYSTEM
ORA
HS
THERMOSTAT
BLK
BLU
BLK
BLU
WHT
WHT
BLK
LAMP
SWITCH
YEL
BLK
BLK
YEL
WHT
L
1-3
2
YEL
WHT
WHT
WHT
GRN
WHT
120 V
SUPPLY
LINE
M
BLK
BLK
RETURN
GROUND
WHT
WHT
GRN
LAMP
LAMP
LAMP
REMOTE
BLOWER ASSEMBLY
ROUGH-IN PLATE
HE0091A
WHT
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
23. SERVICE PARTS
Broan Elite E60000 Series
Internal blower hoods
Broan Elite E60000 Series
Exterior or In-Line blower hoods
1
15
15
2
2
3
6
5
14
14
3
6
7
5
18
17
4
7
4
10
9
16
8
11
12
11
13
13
12
HL0105
HL0106
KEY PART
DESCRIPTION
QTY. (HOOD WIDTH)
30” 36” 42” 48”
KEY PART
NO. NO.
2 SV06750 BROAN ELITE LOGO
3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y
4 SV03435 HEAT SENTRY THERMOSTAT
5 SV08338 LIGHT SWITCH
6 SV03501 SPEED CONTROL
7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)
SV17640 GREASE RAIL 30”
DESCRIPTION
QTY. (HOOD WIDTH)
30” 36” 42” 48”
NO.
NO.
ADAPTER/DAMPER 3¼” X 10”
(1-BLOWER HOOD)
1
2
1
1
1
1
1
-
1
2
1
1
1
1
-
1
-
-
1
3
1
1
1
1
-
-
1
-
1
2
2
1
1
1
1
1
1
1
3
1
1
1
1
-
SV13296
1
1
1
1
1
SV17797 ADAPTER 4½” X 18½” (2-BLOWER HOOD)
2 SV06750 BROAN ELITE LOGO
3 SV16569 LAMP SHELL, SOCKET & TRIM ASS’Y
4 SV03435 HEAT SENTRY THERMOSTAT
5 SV08338 LIGHT SWITCH
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
6 SV03501 SPEED CONTROL
SV17641 GREASE RAIL 36”
SV17642 GREASE RAIL 42”
-
-
11
7 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS)
8 SV08343 REPLACEMENT CHARCOAL FILTERS (PAIR)
9 SV08344 CHARCOAL FILTER SUPPORTS (PAIR)
-
-
SV17643 GREASE RAIL 48”
12 SV08337 FILTER SPRINGS (4)
1
1
-
4
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
-
INTERNAL MOTOR
(1 OR 2, DEPENDING ON HOOD MODEL)
SV17606 BAFFLE FILTER 8.84” X 15.125”
SV17609 BAFFLE FILTER 11.84” X 15.125”
10 SV08097
1
1
1
1
13
3
1
1
1
1
1
1
SV17640 GREASE RAIL 30”
1
-
-
-
1
-
-
1
-
3
1
1
1
-
-
1
-
1
2
2
1
1
1
-
-
-
14 SV08339 BLOWER ROCKER SWITCH
15 SV08093 PILOT LAMP ASS’Y
16 SV08354 ROUGH-IN PLATE 10” ROUND
17 SV13924 FEMALE CONNECTOR
18 SV13923 MALE CONNECTOR
SV17641 GREASE RAIL 36”
SV17642 GREASE RAIL 42”
11
SV17643 GREASE RAIL 48”
12 SV08337 FILTER SPRINGS (4)
-
1
1
-
4
1
1
1
1
2
1
1
1
1
SV17606 BAFFLE FILTER 8.84” X 15.125”
SV17609 BAFFLE FILTER 11.84” X 15.125”
13
*
SV08340 INSTALLATION GUIDE
PARTS BAG ([2] WIRE CONNECTORS,
[9] SCREWS NO. 8 X 1/2”,
14 SV08339 BLOWER ROCKER SWITCH
15 SV08093 PILOT LAMP ASS’Y
[1] WIRE CLAMP, [3] WALL ANCHORS,
[3] WASHERS 13/64’’ ID x 3/4’’ OD,
[4] SCREWS NO. 8 X 3/8”)
*
SV08340 INSTALLATION GUIDE
*
SV08352
1
1
1
1
PARTS BAG ([2] WIRE CONNECTORS,
[9] SCREWS NO. 8 X 1/2”,
[1] WIRE CLAMP, [3] WALL ANCHORS,
[3] WASHERS 13/64’’ ID x 3/4’’ OD,
[4] SCREWS NO. 8 X 3/8”)
[8] SCREWS NO. 8 X 3/4”,
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,
[4] FLAT HEAD SCREWS NO. 10-2”)
*
SV08352
1
1
1
1
* NOT SHOWN.
[8] SCREWS NO. 8 X 3/4”,
[8] MECHANICAL SCREWS NO. 8-32 X 1/4”,
[4] FLAT HEAD SCREWS NO. 10-2”)
* NOT SHOWN.
- 16 -