Bradley Smoker Plumbing Product TDB3104 User Manual

Installation  
Instructions  
TDB3104  
Terreon® 54" Semi-Circular Deep  
Bowl Washfountain with  
Air Metering Valve  
TDB3104 with Push Button Air Valve  
WF3204  
Terreon® Extra Height 54" Semi-  
Circular Classic Washfountain  
with 9" Deep Bowl and  
Air Metering Valve  
TDB3104 Juvenile Height with  
Push Button Air Valve  
Table of Contents  
Pre-Installation Information . . . . . . . . . . . . . . . . . 2  
Model TDB3104 Washfountain Dimensions . . . . 3  
Model WF3204 Washfountain Dimensions . . . . . .4  
Washfountain Rough-Ins . . . . . . . . . . . . . . . . . . 5-7  
Drain Installation . . . . . . . . . . . . . . . . . . . . . . . . . .8  
Bowl/Pedestal Mounting and Assembly . . . . . . . .9  
Drain Spud Installation . . . . . . . . . . . . . . . . . . . . .10  
Air Valve Installation (A/O drains) . . . . . . . . .11-12  
Air Valve Installation (B/H drains) . . . . . . . . .13-14  
Valve and Tubing Connections . . . . . . . . . . . .15-17  
Vernatherm Adjustment Procedure . . . . . . . . . . . .18  
Terreon® Cleaning/Maintenance . . . . . . . . . . . . .19  
Gel-Coated Fiberglass Cleaning/Maintenance . . .19  
Stainless Steel Cleaning/Maintenance . . . . . . . . .20  
Soap Dispensing Valve Repair Parts . . . . . . . . . .21  
Soap Recommendations and Maintenance . . . . . .23  
Sprayhead Troubleshooting/Repair Parts . . . . . . 24  
Actuator Module Assembly Components . . . . . .25  
Metering Air Valve Maintenance . . . . . . . . . .25-27  
Vernatherm™ Mixing Valve Maintenance . . .28-29  
Cleaning the Strainer . . . . . . . . . . . . . . . . . . . .28-29  
TDB3104 TAS Height with  
Push Button Air Valve  
WF3204 with Push Button Air Valve  
215-1470 Rev. H; EN 06-915  
© 2007 Bradley Corporation  
P.O. Box 309, Menomonee Falls, WI 53052-0309  
TEL. 1-800-BRADLEY FAX 262-251-5817  
Page 1 of 29  
2/8/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Semi-Circular Washfountain Dimensions  
Model TDB3104  
54" Semi-circular - side view  
32-1/4"  
(819)  
Optional equipment may not comply with all ADA  
dimensional guidelines  
5-1/4"  
(133)  
ADJUST TO  
TOWEL DISPENSER  
MOUNTING HOLES  
6"  
(152)  
64" (1626) WITH SOAP  
55-1/2" (1410) WITHOUT SOAP  
22-3/4"  
(577)  
55-3/4"  
(1416)  
47-1/4"  
(1200)  
43-3/4"  
(1111)  
40"  
(1016)  
34"  
(864)  
27"  
(686)  
23-1/2"  
(597)  
Figure 1a  
15"  
(381  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Semi-Circular Washfountain Dimensions (juvenile height)  
32-1/4"  
(819)  
Model TDB3104  
54" Semi-circular - side view  
5-1/4"  
(133)  
Optional equipment may not comply with all ADA  
dimensional guidelines  
ADJUST TO  
TOWEL DISPENSER  
MOUNTING HOLES  
6"  
(152)  
*59-1/2" (1511) WITH SOAP  
*51" (1295) WITHOUT SOAP  
22-3/4"  
(577)  
*51-1/4"  
(1301)  
*42-5/8"  
(1084)  
*39-1/8"  
(994)  
*34"  
(864)  
*30"  
(762)  
Figure 1b  
*23-1/2"  
(597)  
15"  
(381  
* ADD 2" (51) FOR TAS HEIGHT UNIT  
12-1/2"  
(318)  
54" Semi-circular - rear view  
pedestal access  
Figure 1c  
17-1/2"  
(444)  
*3-1/2"  
(89)  
4
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Semi-Circular Washfountain Dimensions  
32-1/4"  
(819)  
Model WF3204  
54" Semi-circular - side view  
22-3/4"  
(577)  
Model WF3204 is not ADA compliant  
5-1/4"  
(133)  
ADJUST TO  
TOWEL DISPENSER  
MOUNTING HOLES  
6"  
(152)  
64" (1626) WITH SOAP  
55-1/2" (1410) WITHOUT SOAP  
55-3/4"  
(1416)  
47-1/4"  
(1200)  
43-3/4"  
(1111)  
41"  
(1041)  
34"  
(864)  
23-1/2"  
(597)  
Figure 1d  
15"  
(381  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Rough-In Specifications  
Type A Drain  
- Supplies from below or through wall  
- Vent from below or through wall  
off-drain  
(mm)  
NOTE: Supply lines for one to two  
washfountains should be 1”; for three  
washfountains, 1-1/4”. For more than  
three washfountains, pipe sizes should  
be increased proportionately.  
Figure 2a  
Type B Drain  
- Supplies from above  
- Vent through ceiling off trap inside  
pedestal  
(mm)  
NOTE: Supply lines for one to two  
washfountains should be 1”; for three  
washfountains, 1-1/4”. For more than  
three washfountains, pipe sizes should  
be increased proportionately.  
Figure 2b  
6
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Rough-In Specifications continued . . .  
Type H Drain  
- Supplies from below or through wall  
- Vented through ceiling off trap  
inside pedestal  
(mm)  
NOTE: Supply lines for one to two  
washfountains should be 1”; for  
three washfountains, 1-1/4”. For  
more than three washfountains,  
pipe sizes should be increased  
proportionately.  
Figure 2c  
Type O Drain  
- Supplies from above  
- Vented from below or through wall  
off drain  
(mm)  
NOTE: Supply lines for one to two  
washfountains should be 1”; for  
three washfountains, 1-1/4”. For  
more than three washfountains,  
pipe sizes should be increased  
proportionately.  
Figure 2d  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions  
Step 1: Installing the drain  
1. Rough in supply and drain piping as required for your installation (see pages 6-7 for rough-ins  
of the optional installations).  
2. Assemble the drain to the dimension shown in Figure 3 for the bowl you are installing.  
NOTE: All piping shown in dotted lines to be supplied by installer.  
Types B, H  
Vent  
or  
Vented Trap  
(111-024)  
Tie Pipe  
2" NPT Coupling if Tie  
Pipe is not required  
(Supplied by Installer)  
(Supplied by Installer)  
Centerline of  
W
ashfountain  
able 1  
T
B – See  
4"  
Centerline of  
able 1  
T
W
B – See  
ashfountain  
(102)  
Vent  
or  
4"  
(102)  
Optional  
Tie Pipe Bracket  
(S70-082)  
Tie Pipe  
(Supplied by Installer)  
Centerline of  
W
Types A, O  
ashfountain  
able 1  
T
B – See  
4"  
(102)  
See rough-ins  
on Pages 6-7  
for dimensions  
not shown  
Types A, O  
With Tie Pipe  
Bracket Option  
Figure 3  
Table 1 — “B” Trap Dimensions  
Dim  
Standard Height  
23-3/8" (594mm)  
Juvenile Height  
TAS  
B
22-1/2" (572mm)  
24-1/2" (622mm)  
8
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
Step 2: Bowl/pedestal mounting and assembly  
1. Position pedestal at desired location and mark the position of the (2) pedestal wall mounting  
locations and (2) pedestal floor mounting locations (see Figure 5b).  
TAS Option:  
Place TAS spacer on floor over the mounting holes. Place pedestal on top of the spacer.  
2. Secure pedestal to wall and floor with suitable fasteners, 1/2" anchors and 1/2" bolts (supplied by  
installer) (see Figure 5b for floor and wall mounting locations).  
3. Using two to three people, carefully lift bowl onto pedestal (see Figure 5b).  
4. Position bowl so that threaded rods in bowl mate with slotted holes in pedestal (see Figure 5b).  
5. Using 1/4" wing nuts and washers, secure bowl to pedestal, three places (see Figure 5b).  
CAUTION: BOWL SURFACE IS VERY SMOOTH. APPROXIMATE WEIGHT OF BOWL  
IS 146 LBS. (model TDB3104), 136 lbs. (model WF3204) or 101 lbs.  
(TDB3104/JUV). HANDLE WITH CARE!  
TOP VIEW  
DRAIN  
Figure 5a  
FRONT VIEW  
PLACE HANDS  
HERE WHEN  
LIFTING BOWL  
PLACE HANDS  
HERE WHEN  
DRAIN  
LIFTING BOWL  
THREADED ROD  
(Secured by 1/4" wing  
nut and washer)  
WALL MOUNTING  
LOCATIONS  
PEDESTAL  
Figure 5b  
FLOOR MOUNTING LOCATIONS  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
Step 3: Installing drain spud in bowl  
NOTE: Seal between drain spud and drain hole with plumbers putty (supplied by installer).  
1. Loosely attach the drain spud to the bowl with the locknut and washer as shown in Figure 6.  
B Trap Option:  
Attach B Trap to drain spud.  
Tie Pipe Option:  
Attach Tie Pipe Bracket to drain spud.  
2. Tighten the spud and lock nut against the bowl.  
3. Secure the strainer to drain spud with the screws provided.  
4. Connect spud (or B Trap or Tie Pipe Bracket) to drain.  
STRAINER  
S45-067  
SPUD  
112-015  
BOWL  
WASHER  
142-068  
LOCKNUT  
161-021  
DRAIN PRE-PACK  
S45-273  
Figure 6  
10  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
Step 4a: Air Metering Valve assembly for A drain and O drain units without Tie Pipe option  
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 7).  
2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through the support  
tube and connect to valve tube connector. Make sure the spray holes point away from the wall.  
3. Place the upper tie bar (notched at both corners of each end) on top of sprayhead parallel to wall.  
Connect the longer tie rod to the 4-1/4" tie rod using the coupling nut with hex head set screws.  
Run the tie rod assembly down through upper tie bar (see Figure 7 inset) and secure from under-  
neath the bowl using lower tie bar (no notches) and hex nut with socket head set screw.  
COVER  
TIE ROD  
PRE-PACK  
ACTUATOR  
MODULE  
ASSY.  
COUPLING  
NUT  
TIE  
BAR  
SPRAYHEAD  
SUPPLY TUBE  
TIE  
ROD  
SECTION VIEW OF  
A/O UNIT ASSEMBLY  
TIE ROD PRE-PACK  
S45-1336  
TOP COVER  
107-099 (A)  
107-179 (O)  
RESTRAINING BRACKET  
140-126  
MODULE COVER  
1/8" AIR TUBES  
ACTUATOR MODULE ASSY.  
S65-134  
TIE BAR  
SPRAYHEAD  
S05-054B  
STD.TIE ROD 176-008A  
JUV.TIE ROD 176-008  
SUPPORT TUBE  
(STD) S57-005  
(TAS) (JUV) S57-006  
DRAIN  
S45-273  
SUPPORT TUBE  
GASKET  
125-011  
SEMI-CIRC. BOWL  
PRE-PACK  
TERREON® SEMI-CIRCULAR BOWL  
S45-1523  
(PART No. VARIES WITH COLOR OF  
BOWL — CONTACTYOUR LOCAL  
BRADLEY REP. FOR ASSISTANCE)  
1/2" FLEXIBLE  
SUPPLY TUBE  
TIE BAR  
PRE-PACK  
S45-055  
STANDARD PEDESTAL  
ASSY. S17-259  
ACCESS PANEL  
186-1456  
TAS PEDESTAL  
ASSY. S17-345  
A/O  
VALVE ASSY.  
(See Figure 7a)  
(A shown)  
Figure 7  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
4. Place the actuator module assembly on top of sprayhead. Rotate until actuator module locks in  
with tie bar. Drop two 1/8" diameter tubes down to valve assembly and connect to the air valve.  
NOTE: Skip to number 5 for units without soap.  
• For units with soap option, install the spacer, soap dispenser and cover using the third tie rod  
(8-5/8" long) and second coupling nut as shown (see Figure 8). Secure with acorn nut and set  
screw.  
5. Secure actuator module cover and top cover with sprayhead restraining bracket, acorn nut and  
set screw.  
6. FOR A UNIT: Connect supply lines to stops using suitable fittings.  
FOR O UNIT: Install 1/2" nominal copper tubing supply lines (pass them through holes in  
cover down through support column) and connect to stops using suitable fittings.  
Sprayhead troubleshooting. Adjust volume control valve, if necessary, to control water flow.  
UNIT WITH “O” DRAIN AND ACTUATOR MODULE  
SHOWN, ALSO AVAILABLE WITH “A” DRAIN  
TOP COVER  
8-5/8"  
TIE ROD  
SOAP  
DISPENSER  
SPACER  
COUPLING NUT  
MODULE  
4-1/4"  
COVER  
TIE ROD  
TIE ROD  
21-5/8" (STD.)  
18-1/8" (JUV.)  
COUPLING  
NUT  
TIE BAR  
ACTUATOR  
MODULE  
ASSEMBLY  
S65-134  
SUPPORT TUBE  
(STD.) S57-005  
(TAS)(JUV.) S57-006  
SPRAYHEAD  
S05-054B  
Figure 8  
12  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
Step 4b: Air Metering Valve assembly for B and H units and units with Tie Pipe option  
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 9).  
2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through support tube.  
3. Insert the 1-1/2" vent pipe (supplied by installer) down through the support tube and thread into  
vented trap.  
ACTUATOR  
MODULE  
ASSY.  
COVER  
TIE  
BAR  
SPRAYHEAD  
SUPPLY  
TUBE  
SECTION VIEW OF  
B/H UNIT ASSEMBLY  
1-1/2" VENT PIPE  
TOP COVER  
107-185 (B)  
107-048 (H)  
ACTUATOR  
MODULE ASSY.  
S65-134  
MODULE COVER  
TIE BAR  
PRE-PACK  
S45-056  
SPRAYHEAD  
S05-054B  
1/8" AIR TUBES  
SUPPORT TUBE  
(STD) S57-005  
(TAS) (JUV) S57-006  
DRAIN  
S45-273  
SUPPORT TUBE  
GASKET  
TERREON® SEM-CIRCULAR  
BOWL  
125-011  
Part No. varies with color  
of bowl. — Contact your Bradley Rep.  
for assistance.  
SEMI-CIRCULAR  
BOWL PRE-PACK  
S45-1523  
VENTED TRAP  
111-024  
STANDARD PEDESTAL ASSY.  
S17-259  
ACCESS PANEL  
186-1456  
TAS PEDESTAL ASSY.  
S17-345  
VALVE ASSY.  
(See Figure 7a)  
B/H  
(B shown)  
Figure 9  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
4. Place the actuator module assembly on top of the sprayhead. Drop 1/8" diameter tube down to  
the valve assembly and connect to the air valve. Make sure the spray holes point away from the  
wall.  
NOTE: Skip to number 5 for units without soap.  
• For units with soap option, slide the spacer and soap dispenser over the 1-1/2" pipe.  
5. Position the upper tie bar slightly below the module (see Figure 9 inset on previous page) or  
soap dispenser (see Figure 12) and fasten securely to vent pipe with set screws provided. Secure  
top cover to tie bar with two cap screws provided.  
6. FOR B UNIT: Install 1/2" nominal copper supply lines (pass through holes in cover and  
through support column) and connect supply lines to stops using suitable fittings.  
FOR H UNIT ONLY: Connect supply lines to stops using suitable fittings.  
UNIT WITH “H” DRAIN AND ACTUATOR MODULE  
SHOWN, ALSO AVAILABLE WITH “B” DRAIN  
TOP COVER  
SOAP  
DISPENSER  
SPACER  
ACTUATOR  
MODULE  
ASSEMBLY  
S65-134  
MODULE  
COVER  
TIE BAR  
SPRAYHEAD  
S05-054B  
SUPPORT TUBE  
S57-005 (STD.)  
S57-006 (JUV.) (TAS)  
Figure 10  
14  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
VALVE ASSEMBLY S45-2246  
3/8" TUBE TO  
SPRAYHEAD  
THERMOSTATIC MIXING  
VALVE ASSEMBLY  
VOLUME CONTROL VALVE  
FLEXIBLE HOSE  
1/8" TUBING TO  
ACTUATOR  
CHECK STOP  
AIR VALVE  
ASSEMBLY  
CHECK STOP  
AIR VALVE TIMER  
(DO NOT APPLY PIPE SEALANT  
TO COMPRESSION FITTINGS)  
Figure 11a  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
Step 5: Valve and Tubing Connections  
NOTE: Flush supply lines before making connections.  
1. Attach hot and cold flexible supply lines to mixing valve assembly, two places (see Figure 11a  
and Figure 11b).  
2. Hang valve assembly on pedestal valve bracket.  
3. Use wire tie to secure valving to valve bracket.  
VALVE AND TUBING CONNECTIONS - AIR METERING VALVE OPTION  
NOTE: FLUSH SUPPLY LINES BEFORE MAKING CONNECTIONS.  
DO NOT APPLY PIPE SEALANT TO COMPRESSION FITTINGS.  
3/8" TUBE FROM  
SPRAYHEAD  
VALVE  
BRACKET  
1/8" TUBING TO  
ACTUATOR  
FLEXIBLE  
HOSING  
HOT SUPPLY  
VOLUME  
CONTROL  
THERMOSTATIC  
MIXING VALVE  
FLEXIBLE  
HOSING  
COLD SUPPLY  
PEDESTAL  
REAR  
Figure 11b  
16  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
NOTE: Flush supply lines before making connections.  
4. Follow the procedures below and refer to Figure 12 when installing tubing to ensure that you  
achieve a leakproof seal. Install 3/8" supply tubing in the sprayhead using the male tube con-  
nector.  
• Using a sharp razor, cut tubing squarely and remove any burrs. DO NOT pinch or crush end  
of tubing.  
• Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated.  
Tighten nut to secure tube to fitting (make sure nut is securely tightened).  
• If connector leaks, reseat tubing according to above procedure. If leaking persists,  
replace male connector, or call your Bradley representative for assistance.  
MALE  
TUBE  
CONNECTOR  
NUT  
SPRAYHEAD  
TUBING  
TUBING  
Figure 12  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Installation Instructions continued . . .  
NOTE: The Vernatherm TMA valve is NOT factory preset. Upon installation, the temperature of  
this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in  
excess of 110°F (43°C) may cause scalding.  
5. Check the temperature when approximately 1.0 GPM water flow is reached and adjust if neces-  
sary (the range of the valve is 95°F–115°F (35°C–43°C). To adjust the temperature, follow the  
procedure below:  
• Loosen temperature locking nut with wrench.  
• Using a blade screwdriver, turn the adjustment stem counterclockwise to increase the tempera-  
ture or clockwise to decrease the temperature (Figure 13).  
• Once desired temperature is reached, tighten nut to prevent temperature change.  
6. Clean sprayhead if necessary. See page 24 for sprayhead maintenance and repair parts. Adjust the  
volume control valve, if necessary, to control the flow of water.  
7. Attach pedestal access panel with hardware provided.  
8. Attach kick plate to pedestal base with hardware provided.  
TEMPERATURE  
ADJUSTMENT  
STEM  
TEMPERATURE  
LOCKING  
NUT  
Figure 13  
18  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Cleaning/Maintenance Instructions for Terreon®  
Material Description: Terreon® is a NAHB Certified densified solid surface material composed of polyester  
resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with  
everyday cleansers or fine grit abrasives.  
Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household  
cleaner such as Formula 409® or Windex®.  
Stubborn Stains: Remove tough stains with Ajax®, Comet®, or Soft-Scrub® and a green Scotch-Brite® pad or  
lightly sand in a circular motion with 240 grit wet/dry sandpaper. The finish can be renewed with a maroon  
Scotch-Brite pad.  
Special Situations for Material  
Scratches: Remove scratches with a green Scotch-Brite® pad. The finish can then be renewed with a maroon  
Scotch-Brite® pad.  
Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse  
the unit thoroughly after cleaning.  
Restoring the Surface: Use Hope's® Solid Surface cleaner and polish to refresh and protect the Terreon  
Solid Surface material. Bradley recommends additional care and maintenance for the darker colored Terreon,  
for complete instructions on this additional maintenance see Bradley document #1505.  
IMPORTANT: DO NOT USE STRONG ACID OR ALKALINE CHEMICALS AND CLEANSERS TO  
CLEAN TERREON. IF THESES CHEMICALS COME IN CONTACT WITH THE TERREON SUR-  
FACE WIPE THEM OFF IMMEDIATELY AND RINSE WITH SOAPY WATER. AVOID CONTACT  
WITH HARSH CHEMICALS SUCH AS PAINT REMOVER, BLEACH, ACETONE, ETC. AVOID  
CONTACT WITH HOT PANS AND OBJECTS.  
Repair Kits: Terreon® repair kits are available. Contact your Bradley representative or distributor for part  
numbers and pricing.  
NOTE: Repair kits are made to order and have a shelf life of 30 days.  
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an  
endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named  
are regional in distribution, and can be found in local supermarkets, department and hardware stores, or  
through your cleaning service. It is emphasized that all products should be used in strict accordance with  
package instructions.  
Cleaning/Maintenance Instructions for Gel-coated Fiberglass  
Material Description: The Terreon® Washfountains referenced in this installation manual use a gel-coated  
fiberglass pedestal.  
Routine cleaning: The gel-coated pedestal should be cleaned daily or as often as needed with a mild solution  
of detergent and water. Always use a soft cloth to avoid damage to the finish.  
Repair Kits: There are no repair kits available for fiberglass materials. However, replacement parts are  
available, contact your Bradley representative for pricing and part numbers.  
IMPORTANT: DO NOT EXPOSE GEL-COATED FIBERGLASS TO SOLVENTS AS THEY  
WILL DAMAGE THE MATERIAL AND MAY CREATE HARMFUL FUMES.  
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an  
endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are  
regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your  
cleaning service. It is emphasized that all products should be used in strict accordance with package instructions.  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Cleaning and Maintenance Instructions for Stainless Steel  
Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive.  
Proper care, particularly under corrosive conditions, is essential. Always start with the simplest solution and  
work your way toward the more complicated.  
Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia.  
Apply the cleaning solution per the manufactures instructions and always use a soft cloth or sponge to avoid  
damaging the finish.  
Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball®  
stainless steel cleaner or a soft abrasive. Always follow the manufactures instructions and apply in the same  
direction as the polish lines.  
IMPORTANT: NEVER USE ORDINARY STEEL WOOL OR STEEL BRUSHES ON STAINLESS  
STEEL. ALWAYS USE STAINLESS STEEL WOOL OR STAINLESS STEEL BRUSHES.  
Special Situations for Material  
Finger Prints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and  
polish in accordance with the manufactures instructions. Many of these products leave a protective coating  
the helps prevent future smears and fingerprints.  
Grease and Oil : To remove grease and oil use a quality commercial detergent or caustic cleaner. Apply in  
accordance to the manufactures instructions and in the direction of the polish lines.  
Precautions: Avoid prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thio-  
cyanates (pesticides, photography chemicals, and some foods), and iodides on stainless steel equipment,  
especially if acid conditions exist.  
IMPORTANT: DO NOT PERMIT SALTY SOLUTIONS TO EVAPORATE AND DRY ON  
STAINLESS STEEL.  
The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the  
actual source of the rust in some iron or steel particles which may be touching, but not actually a part of the  
stainless steel structure.  
NOTE: Strongly acidic or caustic cleaners may attack the steel causing a reddish film to appear. The use of  
these cleaners should be avoided.  
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an  
endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are  
regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your  
cleaning service. It is emphasized that all products should be used in strict accordance with package instructions.  
20  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Soap Valve — Liquid — S09-007S  
Parts List  
3
1
Attaching  
Parts  
S09-007S  
Item  
Part No.  
Description  
Qty  
4
1
2
3
4
5
*
118-025  
Valve Body  
Packing Nut  
Spring  
1
1
1
1
1
1
2
1
110-007  
135-001L  
125-001BU  
119-028  
5
Washer  
Plunger  
161-014  
Nut  
2
*
124-001D  
142-002AH  
Washer  
*
Washer - Stainless Steel  
* Not Illustrated  
This valve delivers a measured amount of soap with each upward stroke. The soap dispenser has  
been standard on washfountains since 1983 and is not well-suited for very thick lotion soaps.  
NOTE: Lotion soap will clog liquid soap valves. Use only lotion soap valves with lotion soap.  
Soap Valve — Lotion — S09-057S  
Parts List  
Valve  
Assembly  
S09-057  
Attaching  
Parts  
S09-057S  
5
2
6
4
1
Item  
Part No.  
Description  
Qty  
1
2
3
4
5
6
7
8
124-001D  
110-057  
Washer  
Nut  
1
1
1
1
1
1
1
1
1
3
125-001AN  
159-114  
Stopper  
Reinforcing Plate  
Washer  
Screw  
124-001AT  
160-176  
S09-040  
S53-045  
Valve  
7
8
Adaptor  
1
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Soap Valve — Powdered — S09-010A  
Parts List  
1
Item Part No.  
Qty  
Description  
1
2
3
4
160-069  
142-002X  
S62-002  
192-004  
1
1
1
1
Screw, 1/4-20 RD  
Washer, 1/4 Split-Lock  
Agitator / Slide Assy.  
Lever - Powdered Soap  
2
3
NOTE: Reducer plugs are available for use with fine granulated  
soap to reduce the flow.  
NOTE: Valves can be changed from powdered to liquid by plugging  
the innermost, or “bearing” hole with rubber plug, part number  
125-001AK. To change from liquid to powdered, the plug must be  
removed. If none is present, it will be necessary to drill out the  
bearing hole with a 1/2" or 5/8" drill. The plastic container config-  
uration forms a natural template for locating the bearing hole.  
4
22  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Soap Maintenance Tips  
SOAP RECOMMENDATIONS  
Quality soap dispensers require good quality soap and periodic maintenance to properly operate. Bradley soap  
dispensers will provide dependable, consistent operation over the long term when soap with reasonable viscos-  
ity and pH levels are used and when a minimal amount of periodic maintenance is performed on the valves.  
Soap thickness is determined by a measurement called viscosity. Soap viscosity should be between 100 cps  
(centerpoise) and 2500 cps for all Bradley soap dispensers. Thinner soaps are perceived by the users as being  
"watered down" so users tend to take more than they need, resulting in waste. Thick soaps flow slower and  
inhibit the "flushing" action of the valves, which allows the soap to congeal in the valve and cause clogs.  
The pH (acid) level of the soap should be in the range of 6.5 to 8.5. More acidic soaps (pH levels lower than  
6.5) will corrode metal parts (even stainless steel!!) and degrade rubber and plastic components. They will also  
cause skin irritation. Most inexpensive soaps (typically the pink lotion type) fall into this acidic category and  
will eventually cause valve failure and metal corrosion. Base soaps (pH levels higher than 8.5) will cause  
swelling or degradation of rubber and plastic parts and skin irritation.  
Generally, any quality soap meeting the viscosity and pH guidelines above will work well with Bradley soap  
dispensers. PCMX or Isapropanol based antibacterial soaps (within viscosity and pH limits) will also work  
with Bradley dispensers. Soaps satisfying these basic guidelines will provide consistent flow and reduce clogs.  
Most soap dispenser problems are caused by soap that is too thick or corrosive, or by a lack of maintenance.  
Many soaps come in concentrate form which must be diluted with water. Often, the soap is improperly diluted  
or used straight out of the bottle, which causes clogging and valve failure. If proper soap is being used, valves  
that have never been cleaned are usually the source of dispensing problems. Bradley has entered into an agree-  
ment with Champion Brand Products to provide additional customer service for purchasers of our dispensers  
regarding soap issues. They are very helpful and can get to the bottom of almost any soap dispenser related  
problem. They also sell an excellent "Bradley approved" soap. Please see Soap Instruction Sheet 215-1286  
for details about soap valve cleaning or how to contact Champion. With proper maintenance and soap, Bradley  
dispensers will provide long term, trouble free operation.  
SOAP DISPENSER MAINTENANCE INSTRUCTIONS  
Bradley soap dispensers will provide dependable, consistent operation over the long term when the proper  
soap is used and when a minimal amount of periodic maintenance is performed on the valves. Valves must be  
maintained (cleaned) to function properly.  
To ensure proper operation of your soap dispenser, follow these instructions:  
• Once per month, unscrew valve from reservoir and soak it for 30 minutes in hot water.  
• Push valve at least 20 times while it is soaking.  
• Flush soap reservoir with hot water while valve is soaking.  
In cases of extreme clogging, the valve should be disassembled and the parts should be soaked in hot water or  
cleaning solution to restore proper functioning. Soap dispensers that will not be used for extended periods of  
time (schools during summer break, etc.) should be drained, cleaned and left empty until put back into service.  
Soap left on the outside of dispensers can cause discoloration and corrosion of the reservoir (even on stainless  
steel units). All soap should be wiped or scrubbed off daily, then the outside of the dispenser should be rinsed  
with clear water and dried with a soft cloth.  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Sprayheads — Standard w/Neoprene Spray Ring Grommet  
NOTE: Repair kit does not include sprayhead  
2
1
grommet. Order as a separate item.  
4
5
3
9
7
10  
6
8
Parts List  
Sprayhead  
Assembly S05-054B  
Repair Kit  
S45-051  
Item  
Part No.  
Description  
Qty  
1
2
125-001DE  
139-031  
Neoprene Washer-Top  
Sprayhead Manifold  
Washer  
1
1
3
3
1
1
3
3
1
1
1
4
3
124-001AL  
160-211  
4
Carriage Bolt  
Sprayhead Top  
Sprayhead Bottom  
Washer  
4
5
115-061  
4
6
116-008  
7
124-001AT  
161-025  
8
Nut  
4
9
124-020D  
125-001DF  
Sprayhead Grommet - Semi-circle  
Neoprene Washer-Bottom  
1
10  
Sprayhead Service Suggestions  
Problem: Water splashes over the rim of the bowl.  
Cause: Foreign matter has reduced the size of the sprayhead slots, causing greater pressure at the open slots.  
Solution: Clean the sprayhead:  
1. Disassemble the sprayhead and dislodge any dirt, lime build-up and foreign debris with a wire brush.  
2. Sprayheads with rubber grommet spray rings may be cleaned by rubbing a coin over the grommet.  
3. Throttle down the volume control (water spray should strike the bowl without splashing outside of the bowl).  
Problem: Water flow diminishes from the sprayhead.  
Cause: Strainer portion of the stop-strainer-check valve is plugged.  
Solution: Remove and clean the strainer screen from the stop-strainer-check valve.  
NOTE: The sprayhead shown above includes a perforated neopreme spray ring grommet that is self-cleaning. The water pressure flexes  
the spray holes which slows accumulation of foreign matter and tends to “break loose” any such deposits that may have accumulated.  
24  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Actuator Module Components  
Piston * (119-227A)  
U-Cup * (125-099)  
Spring * (135-065)  
Screw (160-165)  
Duckbill Check * (198-010)  
Actuator Body * (118-279)  
Pushbutton  
Assembly  
(S08-324)  
Straight Tube Connector * (169-890)  
Nut (110-115)  
Actuator Bracket (140-743)  
* Included in Actuator Assembly S65-168  
WATER TUBE CONNECTOR  
AIR VALVE  
Metering Air Valve Maintenance  
Adjust Air Valve Meter Time  
NOTE: The air valve timer is located next to the tube connector  
on the air valve body. The timer is capped with a filter to prevent  
dirt build-up on the timer. The air valve timing can be adjusting  
from 5–60 seconds.  
FILTER CAP  
1. Remove filter cap and use a screwdriver to tighten or  
loosen the timer (see illustration at right). Turning the  
timer clockwise increases the time; turning the timer coun-  
terclockwise decreases the time.  
AIR TUBE  
CONNECTOR  
2. Continue to adjust until the timer is set at desired length.  
3. Replace filter cap over the timer.  
Tube Connection Leaks  
1. Push in the white manual release button while pulling the  
tube out (see illustration at right) to disconnect the tube at  
the connector. No tools are needed.  
2. To correct a leak, press tubing firmly into the connector  
and make sure it is seated.  
3. If leak persists, remove tubing from the fitting, and trim  
the tubing end square with a razor-sharp knife. If leak con-  
tinues, replace the fitting or contact your Bradley represen-  
tative for assistance.  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
AST4 Valve Repair Kits  
13  
1
14  
2
3
8
9
10  
4
12  
11  
5
6
7
AST4 Valve Repair Kits  
AST 4  
Valve Kit  
S65-260  
Repair Kit  
(Upper)  
S65-261  
Repair Kit  
(Lower)  
S65-262  
AST4  
5/16" Tube Valve  
S07-079S  
Item  
Description  
Qty  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
Diaphragm  
Armature  
Spring  
1
1
1
1
1
1
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AST 4 Valve Upper Body  
Magnet / Diaghragm Assembly  
AST 4 Valve Cover  
AST 4 Valve Clamp Nut  
AST 4 Valve Timer Assembly  
O-Ring, #2-012  
AST 4 Valve Timer Cover  
Screw, #8 x 7/8"  
Compression Nut, 1/8" Tube  
Valve Body 5/16 Tube  
O - Ring  
1
1
1
26  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Metering Air Valve Troubleshooting  
Problem: Valve will not shut off.  
Cause: Timing mechanism is clogged.  
Solution: Clean and inspect timing mechanism:  
1. If compressed air is available, blow water and debris from timer cover of timing mechanism.  
2. Turn adjusting screw out all the way. Clean and inspect screw and valve body.  
3. Turn adjusting screw in to desired cycle time.  
Problem: Valve will not turn on.  
Cause: Water is not being supplied to unit.  
Solution: Open all stops on mixing valve.  
Cause: Water pressure is over 80 PSI.  
Solution: Install a pressure reducing valve.  
Cause: Failed diaphragm/magnet assembly.  
Solution: Unscrew the valve clamp nut on valve. Remove valve cover. Gently press the the  
diaphragm. The valve should activate. If not, replace the diaphragm/magnet assembly.  
Problem: Timing can not be adjusted for more than 5 seconds.  
Cause: There is an air leak  
Solution: Check the valve assembly:  
1. Check all tubing and fittings for proper assembly.  
2. Tighten cap and nut on 1/8" tubing.  
Problem: Pushbutton does not work properly.  
Cause: Air volume may not be sufficient to operate valve.  
Solution: Check for leaks and lubricate U-cup:  
1. Check all fittings for air leaks.  
2. Disassemble pushbutton and lubricate U-cup seal (see pushbutton assembly diagram on page 25).  
Problem: Water is dripping from the streamformers.  
Cause: Debris has accumulated on valve seat or orifices.  
Solution: Clean and inspect valve seat.  
1. Remove screws and disassemble metering valve.  
2. Clean valve seat and inspect for deep gouges or scratches. Replace valve body if necessary.  
3. Remove any debris clogging off-center hole in rubber diaphragm.  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Thermostatic Mixing Valve Troubleshooting  
NOTE: Before attempting to troubleshoot the valve or disassemble the components, check for the fol-  
lowing conditions:  
• If stop/check valves are used, make sure that they are fully open.  
• Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-  
connections or leaking stop/check valves.  
• Check the hot water heater output to make sure that it is at least 20° F above the set tempera-  
ture.  
Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the  
valves after inspection and repair is complete.  
Problem: Limited water flow  
Cause: Dirt and debris have built up in the valve or strainer.  
1. Remove and clean strainer (see Figure 14 or 15 on page 29). If strainer needs to be replaced,  
order Bradley part no. 173-028.  
2. Check the piston for smooth movement.  
To check the valve's piston for free and smooth movement, follow the procedures outlined below:  
1. Remove the valve's cap and thermostat (see Figure 14 on Page 29).  
2. Push down on the piston with your finger (the piston should move freely). If the movement is  
not as it should be, the piston needs to be cleaned. Follow the method outlined below for clean-  
ing the piston and valve body:  
• Remove the thermostat.  
• Lift the piston out with a needle-nose pliers and remove the spring.  
• Any cleaner suitable for brass and stainless steel may be used (if cleaning with suitable cleaner  
is not sufficient to remove debris, a 400-grit sandpaper may be used to polish and hone the pis-  
ton and valve body).  
• Snap spring into piston (will detent) and reassemble into the valve body. Retest the piston.  
3. If, after a thorough cleaning, the piston does not move freely, the piston must be replaced.  
Contact your Bradley representative and ask for Repair Kit (part number S65-259).  
Problem: External leaks in the system  
Cause: O-rings have been damaged.  
Solution: Replace O-rings where necessary. For replacement of the O-rings, contact your  
Bradley representative and ask for Repair Kit (part number S65-259).  
Problem: Improper water temperature or temperature fluctuation  
Cause: Thermostat is slowly failing or not working at all.  
Solution: Check the thermostat for proper operation.  
1. At room temperature (80° F or less) remove cap and thermostat.  
2. Place thermostat into container with 115° F water. The pushrod should pop out of the  
thermostat approximately 1/10".  
3. If thermostat pushrod does not pop out, the thermostat must be replaced. Contact your Bradley  
representative and ask for Repair Kit (part number S65-259).  
Cause: Valve temperature is not properly set.  
Solution: Adjust the temperature. Using a blade screwdriver, turn the adjustment stem counterclock-  
wise to increase the temperature or clockwise to decrease the temperature.  
28  
2/8/07  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve  
TDB3104, WF3204  
Installation Instructions  
Vernatherm™ Thermostatic Mixing Valve (S01-524)  
Repair Kit S65-259  
10  
Nut 3/8-24 Hex Jam  
Cap  
Item Qty  
Description  
5
7
8
1
1
1
Thermostat  
O-Ring  
O-Ring  
9
8
7
O-Ring  
O-Ring  
6
5
Stem  
Thermostat  
Piston  
4
3
Spring  
2
Seal Cup  
1
Valve Body  
Strainer  
11  
(173-028)  
Figure 14  
Tempered Line Adapter Assembly (S39-685) Option  
Figure 15  
Strainer  
173-028  
Bradley Corporation • 215-1470 Rev. H; EN 06-915  
2/8/07  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bissell Vacuum Cleaner 4104 User Manual
Blue Coat Systems Crib Toy SGOS 4x User Manual
Brinkmann Charcoal Grill Grill King DeLuxe Heavy Duty Outdoor Charcoal Grill Smoker User Manual
Bryan Boilers Boiler Broile System User Manual
Butler Coffeemaker 645 067 User Manual
Casablanca Fan Company Fan 59536 User Manual
Casio Clock MA1405 EA User Manual
Casio Digital Camera EX Z 2 User Manual
Chicago Electric Indoor Furnishings 40148 User Manual
Chromalox Air Conditioner UB 2502A User Manual