Installation
Instructions
TDB3104
Terreon® 54" Semi-Circular Deep
Bowl Washfountain with
Air Metering Valve
TDB3104 with Push Button Air Valve
WF3204
Terreon® Extra Height 54" Semi-
Circular Classic Washfountain
with 9" Deep Bowl and
Air Metering Valve
TDB3104 Juvenile Height with
Push Button Air Valve
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . 2
Model TDB3104 Washfountain Dimensions . . . . 3
Model WF3204 Washfountain Dimensions . . . . . .4
Washfountain Rough-Ins . . . . . . . . . . . . . . . . . . 5-7
Drain Installation . . . . . . . . . . . . . . . . . . . . . . . . . .8
Bowl/Pedestal Mounting and Assembly . . . . . . . .9
Drain Spud Installation . . . . . . . . . . . . . . . . . . . . .10
Air Valve Installation (A/O drains) . . . . . . . . .11-12
Air Valve Installation (B/H drains) . . . . . . . . .13-14
Valve and Tubing Connections . . . . . . . . . . . .15-17
Vernatherm Adjustment Procedure . . . . . . . . . . . .18
Terreon® Cleaning/Maintenance . . . . . . . . . . . . .19
Gel-Coated Fiberglass Cleaning/Maintenance . . .19
Stainless Steel Cleaning/Maintenance . . . . . . . . .20
Soap Dispensing Valve Repair Parts . . . . . . . . . .21
Soap Recommendations and Maintenance . . . . . .23
Sprayhead Troubleshooting/Repair Parts . . . . . . 24
Actuator Module Assembly Components . . . . . .25
Metering Air Valve Maintenance . . . . . . . . . .25-27
Vernatherm™ Mixing Valve Maintenance . . .28-29
Cleaning the Strainer . . . . . . . . . . . . . . . . . . . .28-29
TDB3104 TAS Height with
Push Button Air Valve
WF3204 with Push Button Air Valve
215-1470 Rev. H; EN 06-915
© 2007 Bradley Corporation
P.O. Box 309, Menomonee Falls, WI 53052-0309
TEL. 1-800-BRADLEY FAX 262-251-5817
Page 1 of 29
2/8/07
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Semi-Circular Washfountain Dimensions
Model TDB3104
54" Semi-circular - side view
32-1/4"
(819)
Optional equipment may not comply with all ADA
dimensional guidelines
5-1/4"
(133)
ADJUST TO
TOWEL DISPENSER
MOUNTING HOLES
6"
(152)
64" (1626) WITH SOAP
55-1/2" (1410) WITHOUT SOAP
22-3/4"
(577)
55-3/4"
(1416)
47-1/4"
(1200)
43-3/4"
(1111)
40"
(1016)
34"
(864)
27"
(686)
23-1/2"
(597)
Figure 1a
15"
(381
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Semi-Circular Washfountain Dimensions (juvenile height)
32-1/4"
(819)
Model TDB3104
54" Semi-circular - side view
5-1/4"
(133)
Optional equipment may not comply with all ADA
dimensional guidelines
ADJUST TO
TOWEL DISPENSER
MOUNTING HOLES
6"
(152)
*59-1/2" (1511) WITH SOAP
*51" (1295) WITHOUT SOAP
22-3/4"
(577)
*51-1/4"
(1301)
*42-5/8"
(1084)
*39-1/8"
(994)
*34"
(864)
*30"
(762)
Figure 1b
*23-1/2"
(597)
15"
(381
* ADD 2" (51) FOR TAS HEIGHT UNIT
12-1/2"
(318)
54" Semi-circular - rear view
pedestal access
Figure 1c
17-1/2"
(444)
*3-1/2"
(89)
4
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Semi-Circular Washfountain Dimensions
32-1/4"
(819)
Model WF3204
54" Semi-circular - side view
22-3/4"
(577)
Model WF3204 is not ADA compliant
5-1/4"
(133)
ADJUST TO
TOWEL DISPENSER
MOUNTING HOLES
6"
(152)
64" (1626) WITH SOAP
55-1/2" (1410) WITHOUT SOAP
55-3/4"
(1416)
47-1/4"
(1200)
43-3/4"
(1111)
41"
(1041)
34"
(864)
23-1/2"
(597)
Figure 1d
15"
(381
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Rough-In Specifications
Type A Drain
- Supplies from below or through wall
- Vent from below or through wall
off-drain
(mm)
NOTE: Supply lines for one to two
washfountains should be 1”; for three
washfountains, 1-1/4”. For more than
three washfountains, pipe sizes should
be increased proportionately.
Figure 2a
Type B Drain
- Supplies from above
- Vent through ceiling off trap inside
pedestal
(mm)
NOTE: Supply lines for one to two
washfountains should be 1”; for three
washfountains, 1-1/4”. For more than
three washfountains, pipe sizes should
be increased proportionately.
Figure 2b
6
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Rough-In Specifications continued . . .
Type H Drain
- Supplies from below or through wall
- Vented through ceiling off trap
inside pedestal
(mm)
NOTE: Supply lines for one to two
washfountains should be 1”; for
three washfountains, 1-1/4”. For
more than three washfountains,
pipe sizes should be increased
proportionately.
Figure 2c
Type O Drain
- Supplies from above
- Vented from below or through wall
off drain
(mm)
NOTE: Supply lines for one to two
washfountains should be 1”; for
three washfountains, 1-1/4”. For
more than three washfountains,
pipe sizes should be increased
proportionately.
Figure 2d
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions
Step 1: Installing the drain
1. Rough in supply and drain piping as required for your installation (see pages 6-7 for rough-ins
of the optional installations).
2. Assemble the drain to the dimension shown in Figure 3 for the bowl you are installing.
NOTE: All piping shown in dotted lines to be supplied by installer.
Types B, H
Vent
or
Vented Trap
(111-024)
Tie Pipe
2" NPT Coupling if Tie
Pipe is not required
(Supplied by Installer)
(Supplied by Installer)
Centerline of
W
ashfountain
able 1
T
B – See
4"
Centerline of
able 1
T
W
B – See
ashfountain
(102)
Vent
or
4"
(102)
Optional
Tie Pipe Bracket
(S70-082)
Tie Pipe
(Supplied by Installer)
Centerline of
W
Types A, O
ashfountain
able 1
T
B – See
4"
(102)
See rough-ins
on Pages 6-7
for dimensions
not shown
Types A, O
With Tie Pipe
Bracket Option
Figure 3
Table 1 — “B” Trap Dimensions
Dim
Standard Height
23-3/8" (594mm)
Juvenile Height
TAS
B
22-1/2" (572mm)
24-1/2" (622mm)
8
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
Step 2: Bowl/pedestal mounting and assembly
1. Position pedestal at desired location and mark the position of the (2) pedestal wall mounting
locations and (2) pedestal floor mounting locations (see Figure 5b).
TAS Option:
Place TAS spacer on floor over the mounting holes. Place pedestal on top of the spacer.
2. Secure pedestal to wall and floor with suitable fasteners, 1/2" anchors and 1/2" bolts (supplied by
installer) (see Figure 5b for floor and wall mounting locations).
3. Using two to three people, carefully lift bowl onto pedestal (see Figure 5b).
4. Position bowl so that threaded rods in bowl mate with slotted holes in pedestal (see Figure 5b).
5. Using 1/4" wing nuts and washers, secure bowl to pedestal, three places (see Figure 5b).
CAUTION: BOWL SURFACE IS VERY SMOOTH. APPROXIMATE WEIGHT OF BOWL
IS 146 LBS. (model TDB3104), 136 lbs. (model WF3204) or 101 lbs.
(TDB3104/JUV). HANDLE WITH CARE!
TOP VIEW
DRAIN
Figure 5a
FRONT VIEW
PLACE HANDS
HERE WHEN
LIFTING BOWL
PLACE HANDS
HERE WHEN
DRAIN
LIFTING BOWL
THREADED ROD
(Secured by 1/4" wing
nut and washer)
WALL MOUNTING
LOCATIONS
PEDESTAL
Figure 5b
FLOOR MOUNTING LOCATIONS
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
Step 3: Installing drain spud in bowl
NOTE: Seal between drain spud and drain hole with plumber’s putty (supplied by installer).
1. Loosely attach the drain spud to the bowl with the locknut and washer as shown in Figure 6.
B Trap Option:
Attach B Trap to drain spud.
Tie Pipe Option:
Attach Tie Pipe Bracket to drain spud.
2. Tighten the spud and lock nut against the bowl.
3. Secure the strainer to drain spud with the screws provided.
4. Connect spud (or B Trap or Tie Pipe Bracket) to drain.
STRAINER
S45-067
SPUD
112-015
BOWL
WASHER
142-068
LOCKNUT
161-021
DRAIN PRE-PACK
S45-273
Figure 6
10
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
Step 4a: Air Metering Valve assembly for A drain and O drain units without Tie Pipe option
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 7).
2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through the support
tube and connect to valve tube connector. Make sure the spray holes point away from the wall.
3. Place the upper tie bar (notched at both corners of each end) on top of sprayhead parallel to wall.
Connect the longer tie rod to the 4-1/4" tie rod using the coupling nut with hex head set screws.
Run the tie rod assembly down through upper tie bar (see Figure 7 inset) and secure from under-
neath the bowl using lower tie bar (no notches) and hex nut with socket head set screw.
COVER
TIE ROD
PRE-PACK
ACTUATOR
MODULE
ASSY.
COUPLING
NUT
TIE
BAR
SPRAYHEAD
SUPPLY TUBE
TIE
ROD
SECTION VIEW OF
A/O UNIT ASSEMBLY
TIE ROD PRE-PACK
S45-1336
TOP COVER
107-099 (A)
107-179 (O)
RESTRAINING BRACKET
140-126
MODULE COVER
1/8" AIR TUBES
ACTUATOR MODULE ASSY.
S65-134
TIE BAR
SPRAYHEAD
S05-054B
STD.TIE ROD 176-008A
JUV.TIE ROD 176-008
SUPPORT TUBE
(STD) S57-005
(TAS) (JUV) S57-006
DRAIN
S45-273
SUPPORT TUBE
GASKET
125-011
SEMI-CIRC. BOWL
PRE-PACK
TERREON® SEMI-CIRCULAR BOWL
S45-1523
(PART No. VARIES WITH COLOR OF
BOWL — CONTACTYOUR LOCAL
BRADLEY REP. FOR ASSISTANCE)
1/2" FLEXIBLE
SUPPLY TUBE
TIE BAR
PRE-PACK
S45-055
STANDARD PEDESTAL
ASSY. S17-259
ACCESS PANEL
186-1456
TAS PEDESTAL
ASSY. S17-345
A/O
VALVE ASSY.
(See Figure 7a)
(A shown)
Figure 7
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
4. Place the actuator module assembly on top of sprayhead. Rotate until actuator module locks in
with tie bar. Drop two 1/8" diameter tubes down to valve assembly and connect to the air valve.
NOTE: Skip to number 5 for units without soap.
• For units with soap option, install the spacer, soap dispenser and cover using the third tie rod
(8-5/8" long) and second coupling nut as shown (see Figure 8). Secure with acorn nut and set
screw.
5. Secure actuator module cover and top cover with sprayhead restraining bracket, acorn nut and
set screw.
6. FOR A UNIT: Connect supply lines to stops using suitable fittings.
FOR O UNIT: Install 1/2" nominal copper tubing supply lines (pass them through holes in
cover down through support column) and connect to stops using suitable fittings.
Sprayhead troubleshooting. Adjust volume control valve, if necessary, to control water flow.
UNIT WITH “O” DRAIN AND ACTUATOR MODULE
SHOWN, ALSO AVAILABLE WITH “A” DRAIN
TOP COVER
8-5/8"
TIE ROD
SOAP
DISPENSER
SPACER
COUPLING NUT
MODULE
4-1/4"
COVER
TIE ROD
TIE ROD
21-5/8" (STD.)
18-1/8" (JUV.)
COUPLING
NUT
TIE BAR
ACTUATOR
MODULE
ASSEMBLY
S65-134
SUPPORT TUBE
(STD.) S57-005
(TAS)(JUV.) S57-006
SPRAYHEAD
S05-054B
Figure 8
12
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
Step 4b: Air Metering Valve assembly for B and H units and units with Tie Pipe option
1. Install hemmed end (not sharp end) of support tube with gasket onto bowl (see Figure 9).
2. Place sprayhead with 1/2" tubing onto support tube. Run the tubing down through support tube.
3. Insert the 1-1/2" vent pipe (supplied by installer) down through the support tube and thread into
vented trap.
ACTUATOR
MODULE
ASSY.
COVER
TIE
BAR
SPRAYHEAD
SUPPLY
TUBE
SECTION VIEW OF
B/H UNIT ASSEMBLY
1-1/2" VENT PIPE
TOP COVER
107-185 (B)
107-048 (H)
ACTUATOR
MODULE ASSY.
S65-134
MODULE COVER
TIE BAR
PRE-PACK
S45-056
SPRAYHEAD
S05-054B
1/8" AIR TUBES
SUPPORT TUBE
(STD) S57-005
(TAS) (JUV) S57-006
DRAIN
S45-273
SUPPORT TUBE
GASKET
TERREON® SEM-CIRCULAR
BOWL
125-011
Part No. varies with color
of bowl. — Contact your Bradley Rep.
for assistance.
SEMI-CIRCULAR
BOWL PRE-PACK
S45-1523
VENTED TRAP
111-024
STANDARD PEDESTAL ASSY.
S17-259
ACCESS PANEL
186-1456
TAS PEDESTAL ASSY.
S17-345
VALVE ASSY.
(See Figure 7a)
B/H
(B shown)
Figure 9
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
4. Place the actuator module assembly on top of the sprayhead. Drop 1/8" diameter tube down to
the valve assembly and connect to the air valve. Make sure the spray holes point away from the
wall.
NOTE: Skip to number 5 for units without soap.
• For units with soap option, slide the spacer and soap dispenser over the 1-1/2" pipe.
5. Position the upper tie bar slightly below the module (see Figure 9 inset on previous page) or
soap dispenser (see Figure 12) and fasten securely to vent pipe with set screws provided. Secure
top cover to tie bar with two cap screws provided.
6. FOR B UNIT: Install 1/2" nominal copper supply lines (pass through holes in cover and
through support column) and connect supply lines to stops using suitable fittings.
FOR H UNIT ONLY: Connect supply lines to stops using suitable fittings.
UNIT WITH “H” DRAIN AND ACTUATOR MODULE
SHOWN, ALSO AVAILABLE WITH “B” DRAIN
TOP COVER
SOAP
DISPENSER
SPACER
ACTUATOR
MODULE
ASSEMBLY
S65-134
MODULE
COVER
TIE BAR
SPRAYHEAD
S05-054B
SUPPORT TUBE
S57-005 (STD.)
S57-006 (JUV.) (TAS)
Figure 10
14
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
VALVE ASSEMBLY S45-2246
3/8" TUBE TO
SPRAYHEAD
THERMOSTATIC MIXING
VALVE ASSEMBLY
VOLUME CONTROL VALVE
FLEXIBLE HOSE
1/8" TUBING TO
ACTUATOR
CHECK STOP
AIR VALVE
ASSEMBLY
CHECK STOP
AIR VALVE TIMER
(DO NOT APPLY PIPE SEALANT
TO COMPRESSION FITTINGS)
Figure 11a
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
Step 5: Valve and Tubing Connections
NOTE: Flush supply lines before making connections.
1. Attach hot and cold flexible supply lines to mixing valve assembly, two places (see Figure 11a
and Figure 11b).
2. Hang valve assembly on pedestal valve bracket.
3. Use wire tie to secure valving to valve bracket.
VALVE AND TUBING CONNECTIONS - AIR METERING VALVE OPTION
NOTE: FLUSH SUPPLY LINES BEFORE MAKING CONNECTIONS.
DO NOT APPLY PIPE SEALANT TO COMPRESSION FITTINGS.
3/8" TUBE FROM
SPRAYHEAD
VALVE
BRACKET
1/8" TUBING TO
ACTUATOR
FLEXIBLE
HOSING
HOT SUPPLY
VOLUME
CONTROL
THERMOSTATIC
MIXING VALVE
FLEXIBLE
HOSING
COLD SUPPLY
PEDESTAL
REAR
Figure 11b
16
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
NOTE: Flush supply lines before making connections.
4. Follow the procedures below and refer to Figure 12 when installing tubing to ensure that you
achieve a leakproof seal. Install 3/8" supply tubing in the sprayhead using the male tube con-
nector.
• Using a sharp razor, cut tubing squarely and remove any burrs. DO NOT pinch or crush end
of tubing.
• Loosen nut on fitting. Moisten end of tube and push into fitting until it is firmly seated.
Tighten nut to secure tube to fitting (make sure nut is securely tightened).
• If connector leaks, reseat tubing according to above procedure. If leaking persists,
replace male connector, or call your Bradley representative for assistance.
MALE
TUBE
CONNECTOR
NUT
SPRAYHEAD
TUBING
TUBING
Figure 12
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Installation Instructions continued . . .
NOTE: The Vernatherm TMA valve is NOT factory preset. Upon installation, the temperature of
this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in
excess of 110°F (43°C) may cause scalding.
5. Check the temperature when approximately 1.0 GPM water flow is reached and adjust if neces-
sary (the range of the valve is 95°F–115°F (35°C–43°C). To adjust the temperature, follow the
procedure below:
• Loosen temperature locking nut with wrench.
• Using a blade screwdriver, turn the adjustment stem counterclockwise to increase the tempera-
ture or clockwise to decrease the temperature (Figure 13).
• Once desired temperature is reached, tighten nut to prevent temperature change.
6. Clean sprayhead if necessary. See page 24 for sprayhead maintenance and repair parts. Adjust the
volume control valve, if necessary, to control the flow of water.
7. Attach pedestal access panel with hardware provided.
8. Attach kick plate to pedestal base with hardware provided.
TEMPERATURE
ADJUSTMENT
STEM
TEMPERATURE
LOCKING
NUT
Figure 13
18
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Cleaning/Maintenance Instructions for Terreon®
Material Description: Terreon® is a NAHB Certified densified solid surface material composed of polyester
resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with
everyday cleansers or fine grit abrasives.
Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household
cleaner such as Formula 409® or Windex®.
Stubborn Stains: Remove tough stains with Ajax®, Comet®, or Soft-Scrub® and a green Scotch-Brite® pad or
lightly sand in a circular motion with 240 grit wet/dry sandpaper. The finish can be renewed with a maroon
Scotch-Brite pad.
Special Situations for Material
Scratches: Remove scratches with a green Scotch-Brite® pad. The finish can then be renewed with a maroon
Scotch-Brite® pad.
Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse
the unit thoroughly after cleaning.
Restoring the Surface: Use Hope's® Solid Surface cleaner and polish to refresh and protect the Terreon
Solid Surface material. Bradley recommends additional care and maintenance for the darker colored Terreon,
for complete instructions on this additional maintenance see Bradley document #1505.
IMPORTANT: DO NOT USE STRONG ACID OR ALKALINE CHEMICALS AND CLEANSERS TO
CLEAN TERREON. IF THESES CHEMICALS COME IN CONTACT WITH THE TERREON SUR-
FACE WIPE THEM OFF IMMEDIATELY AND RINSE WITH SOAPY WATER. AVOID CONTACT
WITH HARSH CHEMICALS SUCH AS PAINT REMOVER, BLEACH, ACETONE, ETC. AVOID
CONTACT WITH HOT PANS AND OBJECTS.
Repair Kits: Terreon® repair kits are available. Contact your Bradley representative or distributor for part
numbers and pricing.
NOTE: Repair kits are made to order and have a shelf life of 30 days.
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an
endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named
are regional in distribution, and can be found in local supermarkets, department and hardware stores, or
through your cleaning service. It is emphasized that all products should be used in strict accordance with
package instructions.
Cleaning/Maintenance Instructions for Gel-coated Fiberglass
Material Description: The Terreon® Washfountains referenced in this installation manual use a gel-coated
fiberglass pedestal.
Routine cleaning: The gel-coated pedestal should be cleaned daily or as often as needed with a mild solution
of detergent and water. Always use a soft cloth to avoid damage to the finish.
Repair Kits: There are no repair kits available for fiberglass materials. However, replacement parts are
available, contact your Bradley representative for pricing and part numbers.
IMPORTANT: DO NOT EXPOSE GEL-COATED FIBERGLASS TO SOLVENTS AS THEY
WILL DAMAGE THE MATERIAL AND MAY CREATE HARMFUL FUMES.
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an
endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are
regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your
cleaning service. It is emphasized that all products should be used in strict accordance with package instructions.
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Cleaning and Maintenance Instructions for Stainless Steel
Material Description: Stainless steel is extremely durable, and maintenance is simple and inexpensive.
Proper care, particularly under corrosive conditions, is essential. Always start with the simplest solution and
work your way toward the more complicated.
Routine cleaning: Daily or as often as needed use a solution of warm water and soap, detergent, or ammonia.
Apply the cleaning solution per the manufactures instructions and always use a soft cloth or sponge to avoid
damaging the finish.
Stubborn Stains: To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball®
stainless steel cleaner or a soft abrasive. Always follow the manufactures instructions and apply in the same
direction as the polish lines.
IMPORTANT: NEVER USE ORDINARY STEEL WOOL OR STEEL BRUSHES ON STAINLESS
STEEL. ALWAYS USE STAINLESS STEEL WOOL OR STAINLESS STEEL BRUSHES.
Special Situations for Material
Finger Prints and Smears: To remove fingerprints or smears use a high quality stainless steel cleaner and
polish in accordance with the manufactures instructions. Many of these products leave a protective coating
the helps prevent future smears and fingerprints.
Grease and Oil : To remove grease and oil use a quality commercial detergent or caustic cleaner. Apply in
accordance to the manufactures instructions and in the direction of the polish lines.
Precautions: Avoid prolonged contact with chlorides (bleaches, salts), bromides (sanitizing agents), thio-
cyanates (pesticides, photography chemicals, and some foods), and iodides on stainless steel equipment,
especially if acid conditions exist.
IMPORTANT: DO NOT PERMIT SALTY SOLUTIONS TO EVAPORATE AND DRY ON
STAINLESS STEEL.
The appearance of rust streaks on stainless steel leads to the belief that the stainless steel is rusting. Look for the
actual source of the rust in some iron or steel particles which may be touching, but not actually a part of the
stainless steel structure.
NOTE: Strongly acidic or caustic cleaners may attack the steel causing a reddish film to appear. The use of
these cleaners should be avoided.
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an
endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products named are
regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your
cleaning service. It is emphasized that all products should be used in strict accordance with package instructions.
20
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Soap Valve — Liquid — S09-007S
Parts List
3
1
Attaching
Parts
S09-007S
Item
Part No.
Description
Qty
4
1
2
3
4
5
*
118-025
Valve Body
Packing Nut
Spring
1
1
1
1
1
1
2
1
110-007
135-001L
125-001BU
119-028
5
Washer
Plunger
161-014
Nut
2
*
124-001D
142-002AH
Washer
*
Washer - Stainless Steel
* Not Illustrated
This valve delivers a measured amount of soap with each upward stroke. The soap dispenser has
been standard on washfountains since 1983 and is not well-suited for very thick lotion soaps.
NOTE: Lotion soap will clog liquid soap valves. Use only lotion soap valves with lotion soap.
Soap Valve — Lotion — S09-057S
Parts List
Valve
Assembly
S09-057
Attaching
Parts
S09-057S
5
2
6
4
1
Item
Part No.
Description
Qty
1
2
3
4
5
6
7
8
124-001D
110-057
Washer
Nut
—
—
—
—
—
—
1
1
1
1
1
1
1
1
1
3
125-001AN
159-114
Stopper
Reinforcing Plate
Washer
Screw
124-001AT
160-176
S09-040
S53-045
Valve
7
8
Adaptor
1
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Soap Valve — Powdered — S09-010A
Parts List
1
Item Part No.
Qty
Description
1
2
3
4
160-069
142-002X
S62-002
192-004
1
1
1
1
Screw, 1/4-20 RD
Washer, 1/4 Split-Lock
Agitator / Slide Assy.
Lever - Powdered Soap
2
3
NOTE: Reducer plugs are available for use with fine granulated
soap to reduce the flow.
NOTE: Valves can be changed from powdered to liquid by plugging
the innermost, or “bearing” hole with rubber plug, part number
125-001AK. To change from liquid to powdered, the plug must be
removed. If none is present, it will be necessary to drill out the
bearing hole with a 1/2" or 5/8" drill. The plastic container config-
uration forms a natural template for locating the bearing hole.
4
22
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Soap Maintenance Tips
SOAP RECOMMENDATIONS
Quality soap dispensers require good quality soap and periodic maintenance to properly operate. Bradley soap
dispensers will provide dependable, consistent operation over the long term when soap with reasonable viscos-
ity and pH levels are used and when a minimal amount of periodic maintenance is performed on the valves.
Soap thickness is determined by a measurement called viscosity. Soap viscosity should be between 100 cps
(centerpoise) and 2500 cps for all Bradley soap dispensers. Thinner soaps are perceived by the users as being
"watered down" so users tend to take more than they need, resulting in waste. Thick soaps flow slower and
inhibit the "flushing" action of the valves, which allows the soap to congeal in the valve and cause clogs.
The pH (acid) level of the soap should be in the range of 6.5 to 8.5. More acidic soaps (pH levels lower than
6.5) will corrode metal parts (even stainless steel!!) and degrade rubber and plastic components. They will also
cause skin irritation. Most inexpensive soaps (typically the pink lotion type) fall into this acidic category and
will eventually cause valve failure and metal corrosion. Base soaps (pH levels higher than 8.5) will cause
swelling or degradation of rubber and plastic parts and skin irritation.
Generally, any quality soap meeting the viscosity and pH guidelines above will work well with Bradley soap
dispensers. PCMX or Isapropanol based antibacterial soaps (within viscosity and pH limits) will also work
with Bradley dispensers. Soaps satisfying these basic guidelines will provide consistent flow and reduce clogs.
Most soap dispenser problems are caused by soap that is too thick or corrosive, or by a lack of maintenance.
Many soaps come in concentrate form which must be diluted with water. Often, the soap is improperly diluted
or used straight out of the bottle, which causes clogging and valve failure. If proper soap is being used, valves
that have never been cleaned are usually the source of dispensing problems. Bradley has entered into an agree-
ment with Champion Brand Products to provide additional customer service for purchasers of our dispensers
regarding soap issues. They are very helpful and can get to the bottom of almost any soap dispenser related
problem. They also sell an excellent "Bradley approved" soap. Please see Soap Instruction Sheet 215-1286
for details about soap valve cleaning or how to contact Champion. With proper maintenance and soap, Bradley
dispensers will provide long term, trouble free operation.
SOAP DISPENSER MAINTENANCE INSTRUCTIONS
Bradley soap dispensers will provide dependable, consistent operation over the long term when the proper
soap is used and when a minimal amount of periodic maintenance is performed on the valves. Valves must be
maintained (cleaned) to function properly.
To ensure proper operation of your soap dispenser, follow these instructions:
• Once per month, unscrew valve from reservoir and soak it for 30 minutes in hot water.
• Push valve at least 20 times while it is soaking.
• Flush soap reservoir with hot water while valve is soaking.
In cases of extreme clogging, the valve should be disassembled and the parts should be soaked in hot water or
cleaning solution to restore proper functioning. Soap dispensers that will not be used for extended periods of
time (schools during summer break, etc.) should be drained, cleaned and left empty until put back into service.
Soap left on the outside of dispensers can cause discoloration and corrosion of the reservoir (even on stainless
steel units). All soap should be wiped or scrubbed off daily, then the outside of the dispenser should be rinsed
with clear water and dried with a soft cloth.
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Sprayheads — Standard w/Neoprene Spray Ring Grommet
NOTE: Repair kit does not include sprayhead
2
1
grommet. Order as a separate item.
4
5
3
9
7
10
6
8
Parts List
Sprayhead
Assembly S05-054B
Repair Kit
S45-051
Item
Part No.
Description
Qty
1
2
125-001DE
139-031
Neoprene Washer-Top
Sprayhead Manifold
Washer
1
1
3
3
1
1
3
3
1
1
1
—
4
3
124-001AL
160-211
4
Carriage Bolt
Sprayhead Top
Sprayhead Bottom
Washer
4
5
115-061
—
—
4
6
116-008
7
124-001AT
161-025
8
Nut
4
9
124-020D
125-001DF
Sprayhead Grommet - Semi-circle
Neoprene Washer-Bottom
—
1
10
Sprayhead Service Suggestions
Problem: Water splashes over the rim of the bowl.
Cause: Foreign matter has reduced the size of the sprayhead slots, causing greater pressure at the open slots.
Solution: Clean the sprayhead:
1. Disassemble the sprayhead and dislodge any dirt, lime build-up and foreign debris with a wire brush.
2. Sprayheads with rubber grommet spray rings may be cleaned by rubbing a coin over the grommet.
3. Throttle down the volume control (water spray should strike the bowl without splashing outside of the bowl).
Problem: Water flow diminishes from the sprayhead.
Cause: Strainer portion of the stop-strainer-check valve is plugged.
Solution: Remove and clean the strainer screen from the stop-strainer-check valve.
NOTE: The sprayhead shown above includes a perforated neopreme spray ring grommet that is self-cleaning. The water pressure flexes
the spray holes which slows accumulation of foreign matter and tends to “break loose” any such deposits that may have accumulated.
24
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Actuator Module Components
Piston * (119-227A)
U-Cup * (125-099)
Spring * (135-065)
Screw (160-165)
Duckbill Check * (198-010)
Actuator Body * (118-279)
Pushbutton
Assembly
(S08-324)
Straight Tube Connector * (169-890)
Nut (110-115)
Actuator Bracket (140-743)
* Included in Actuator Assembly S65-168
WATER TUBE CONNECTOR
AIR VALVE
Metering Air Valve Maintenance
Adjust Air Valve Meter Time
NOTE: The air valve timer is located next to the tube connector
on the air valve body. The timer is capped with a filter to prevent
dirt build-up on the timer. The air valve timing can be adjusting
from 5–60 seconds.
FILTER CAP
1. Remove filter cap and use a screwdriver to tighten or
loosen the timer (see illustration at right). Turning the
timer clockwise increases the time; turning the timer coun-
terclockwise decreases the time.
AIR TUBE
CONNECTOR
2. Continue to adjust until the timer is set at desired length.
3. Replace filter cap over the timer.
Tube Connection Leaks
1. Push in the white manual release button while pulling the
tube out (see illustration at right) to disconnect the tube at
the connector. No tools are needed.
2. To correct a leak, press tubing firmly into the connector
and make sure it is seated.
3. If leak persists, remove tubing from the fitting, and trim
the tubing end square with a razor-sharp knife. If leak con-
tinues, replace the fitting or contact your Bradley represen-
tative for assistance.
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
AST4 Valve Repair Kits
13
1
14
2
3
8
9
10
4
12
11
5
6
7
AST4 Valve Repair Kits
AST 4
Valve Kit
S65-260
Repair Kit
(Upper)
S65-261
Repair Kit
(Lower)
S65-262
AST4
5/16" Tube Valve
S07-079S
Item
Description
Qty
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Diaphragm
Armature
Spring
1
1
1
1
1
1
1
1
1
1
3
1
—
—
—
—
—
—
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AST 4 Valve Upper Body
Magnet / Diaghragm Assembly
AST 4 Valve Cover
AST 4 Valve Clamp Nut
AST 4 Valve Timer Assembly
O-Ring, #2-012
AST 4 Valve Timer Cover
Screw, #8 x 7/8"
Compression Nut, 1/8" Tube
Valve Body 5/16 Tube
O - Ring
—
—
—
—
—
—
—
—
—
—
—
1
1
—
—
—
—
1
—
—
26
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Metering Air Valve Troubleshooting
Problem: Valve will not shut off.
Cause: Timing mechanism is clogged.
Solution: Clean and inspect timing mechanism:
1. If compressed air is available, blow water and debris from timer cover of timing mechanism.
2. Turn adjusting screw out all the way. Clean and inspect screw and valve body.
3. Turn adjusting screw in to desired cycle time.
Problem: Valve will not turn on.
Cause: Water is not being supplied to unit.
Solution: Open all stops on mixing valve.
Cause: Water pressure is over 80 PSI.
Solution: Install a pressure reducing valve.
Cause: Failed diaphragm/magnet assembly.
Solution: Unscrew the valve clamp nut on valve. Remove valve cover. Gently press the the
diaphragm. The valve should activate. If not, replace the diaphragm/magnet assembly.
Problem: Timing can not be adjusted for more than 5 seconds.
Cause: There is an air leak
Solution: Check the valve assembly:
1. Check all tubing and fittings for proper assembly.
2. Tighten cap and nut on 1/8" tubing.
Problem: Pushbutton does not work properly.
Cause: Air volume may not be sufficient to operate valve.
Solution: Check for leaks and lubricate U-cup:
1. Check all fittings for air leaks.
2. Disassemble pushbutton and lubricate U-cup seal (see pushbutton assembly diagram on page 25).
Problem: Water is dripping from the streamformers.
Cause: Debris has accumulated on valve seat or orifices.
Solution: Clean and inspect valve seat.
1. Remove screws and disassemble metering valve.
2. Clean valve seat and inspect for deep gouges or scratches. Replace valve body if necessary.
3. Remove any debris clogging off-center hole in rubber diaphragm.
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Thermostatic Mixing Valve Troubleshooting
NOTE: Before attempting to troubleshoot the valve or disassemble the components, check for the fol-
lowing conditions:
• If stop/check valves are used, make sure that they are fully open.
• Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-
connections or leaking stop/check valves.
• Check the hot water heater output to make sure that it is at least 20° F above the set tempera-
ture.
Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the
valves after inspection and repair is complete.
Problem: Limited water flow
Cause: Dirt and debris have built up in the valve or strainer.
1. Remove and clean strainer (see Figure 14 or 15 on page 29). If strainer needs to be replaced,
order Bradley part no. 173-028.
2. Check the piston for smooth movement.
To check the valve's piston for free and smooth movement, follow the procedures outlined below:
1. Remove the valve's cap and thermostat (see Figure 14 on Page 29).
2. Push down on the piston with your finger (the piston should move freely). If the movement is
not as it should be, the piston needs to be cleaned. Follow the method outlined below for clean-
ing the piston and valve body:
• Remove the thermostat.
• Lift the piston out with a needle-nose pliers and remove the spring.
• Any cleaner suitable for brass and stainless steel may be used (if cleaning with suitable cleaner
is not sufficient to remove debris, a 400-grit sandpaper may be used to polish and hone the pis-
ton and valve body).
• Snap spring into piston (will detent) and reassemble into the valve body. Retest the piston.
3. If, after a thorough cleaning, the piston does not move freely, the piston must be replaced.
Contact your Bradley representative and ask for Repair Kit (part number S65-259).
Problem: External leaks in the system
Cause: O-rings have been damaged.
Solution: Replace O-rings where necessary. For replacement of the O-rings, contact your
Bradley representative and ask for Repair Kit (part number S65-259).
Problem: Improper water temperature or temperature fluctuation
Cause: Thermostat is slowly failing or not working at all.
Solution: Check the thermostat for proper operation.
1. At room temperature (80° F or less) remove cap and thermostat.
2. Place thermostat into container with 115° F water. The pushrod should pop out of the
thermostat approximately 1/10".
3. If thermostat pushrod does not pop out, the thermostat must be replaced. Contact your Bradley
representative and ask for Repair Kit (part number S65-259).
Cause: Valve temperature is not properly set.
Solution: Adjust the temperature. Using a blade screwdriver, turn the adjustment stem counterclock-
wise to increase the temperature or clockwise to decrease the temperature.
28
2/8/07
Bradley Corporation • 215-1470 Rev. H; EN 06-915
Download from Www.Somanuals.com. All Manuals Search And Download.
Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve
TDB3104, WF3204
Installation Instructions
Vernatherm™ Thermostatic Mixing Valve (S01-524)
Repair Kit S65-259
10
Nut 3/8-24 Hex Jam
Cap
Item Qty
Description
5
7
8
1
1
1
Thermostat
O-Ring
O-Ring
9
8
7
O-Ring
O-Ring
6
5
Stem
Thermostat
Piston
4
3
Spring
2
Seal Cup
1
Valve Body
Strainer
11
(173-028)
Figure 14
Tempered Line Adapter Assembly (S39-685) Option
Figure 15
Strainer
173-028
Bradley Corporation • 215-1470 Rev. H; EN 06-915
2/8/07
29
Download from Www.Somanuals.com. All Manuals Search And Download.
|