Bosch Appliances Security Camera VEZ 400 User Manual

VEZ-400 Mini PTZ Dome  
VEZ-400 Series  
en User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Table of Contents | en  
3
Table of Contents  
1
Safety  
5
5
1.1  
1.2  
1.3  
1.4  
1.5  
Safety precautions  
Important safety instructions  
Important notices  
FCC & ICES compliance  
Bosch notices  
6
7
10  
13  
2
Description  
15  
2.1  
Features  
15  
3
Unpacking  
16  
16  
17  
17  
3.1  
3.2  
3.3  
Parts List  
Additional Tools Required  
Accessories  
4
5
Installation Overview  
18  
19  
Installing a Surface Mount  
6
Connection  
22  
23  
25  
25  
26  
26  
28  
28  
6.1  
6.2  
6.3  
6.4  
6.5  
6.5.1  
6.5.2  
RS-485 Connections  
Video Connection  
Alarm Connections  
Power Connections  
Camera Settings  
Setting the address (ID) of the camera  
Setting the protocol of the camera  
7
On-Screen Display (OSD) Menu  
Basic Navigation and Common Actions  
Main Menu  
29  
29  
31  
32  
33  
33  
33  
7.1  
7.2  
7.2.1  
7.2.2  
7.3  
Editing Titles  
Clearing Saved Functions  
System Setup Menu  
7.3.1  
System Information  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
en | Table of Contents  
VEZ-400 Mini PTZ Dome  
7.3.2  
7.3.3  
7.3.4  
7.4  
Reboot  
34  
34  
35  
36  
36  
37  
39  
39  
40  
41  
41  
42  
43  
44  
45  
46  
47  
48  
48  
49  
51  
52  
53  
54  
55  
56  
Initialize  
Password  
Display Setup  
OSD Setup  
Privacy Zone  
Image Setup  
Motion/Face Detection  
Language  
7.4.1  
7.4.2  
7.4.3  
7.4.4  
7.4.5  
7.5  
Camera Setup  
Focus/Zoom  
WB Setup  
7.5.1  
7.5.2  
7.5.3  
7.5.4  
7.5.5  
7.5.6  
7.6  
AE Setup  
D/N Setup  
Advanced  
WDR/DNR  
Dome Motion Setup  
General Setup  
Motion Setup  
Home Action  
Calibration  
7.6.1  
7.6.2  
7.6.3  
7.6.4  
7.7  
Preset Setup  
Pattern Setup  
Tour Setup  
7.8  
7.9  
7.10  
7.11  
Scan Setup  
Alarm Setup  
8
Troubleshooting  
Technical Specifications  
Dimensions  
58  
60  
62  
63  
65  
9
10  
11  
12  
Bosch Protocol  
Pelco Protocol  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Safety | en  
5
1
Safety  
Before installing and operating the camera, please read this  
manual carefully.  
1.1  
Safety precautions  
DANGER!  
High risk: This symbol indicates an imminently hazardous  
situation such as "Dangerous Voltage" inside the product.  
If not avoided, this will result in an electrical shock, serious  
bodily injury, or death.  
WARNING!  
Medium risk: Indicates a potentially hazardous situation.  
If not avoided, this could result in minor or moderate bodily  
injury.  
CAUTION!  
Low risk: Indicates a potentially hazardous situation.  
If not avoided, this could result in property damage or risk of  
damage to the unit.  
NOTICE!  
This symbol indicates information or a company policy that  
relates directly or indirectly to the safety of personnel or  
protection of property.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
en | Safety  
VEZ-400 Mini PTZ Dome  
1.2  
Important safety instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow these instructions.  
5. Do not install near any heat sources such as radiators,  
heaters, stoves, or other equipment (including amplifiers)  
that produce heat.  
6. Do not defeat the safety purpose of the polarized or  
grounding-type plug. A polarized plug has two blades with  
one wider than the other. A grounding type plug has two  
blades and a third grounding prong. The wide blade or the  
third prong is provided for your safety. If the provided plug  
does not fit into your outlet, consult an electrician for  
replacement of the obsolete outlet.  
7. Protect the power cord from being walked on or pinched,  
particularly at plugs, convenience receptacles, and the  
point where they exit from the apparatus.  
8. Only use attachments/accessories specified by the  
manufacturer.  
9. Use only with the cart, stand, tripod, bracket, or table  
specified by the manufacturer. When a cart is used, use  
caution when moving the cart/apparatus combination to  
avoid injury from tip-over.  
10. Unplug this apparatus during lightning storms or when l  
unused for long periods of time. This will prevent damage  
to the unit from lightning and power line surges.  
11. Refer all servicing to qualified service personnel. Servicing  
is required when the apparatus has been damaged in a  
way, such as power supply cord or plug is damaged, liquid  
has been spilled or objects have fallen into the apparatus,  
the apparatus has been exposed to rain or moisture, does  
not operate normally, or has been dropped.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Safety | en  
7
1.3  
Important notices  
CAUTION!  
1. A regulated 24 VAC, 43W power supply is recommended  
for use with this camera for the best picture and the most  
stable operation. An unregulated power supply can cause  
damage to the camera. When unregulated power supply is  
applied, product warranty will be void.  
2. Bosch recommends using the camera with a monitor that  
has a CCTV-quality 75 Ohm video impedance level. If your  
monitor is switched to high impedance, please adjust  
accordingly.  
3. Do not attempt to disassemble the camera to gain access  
to the internal components. Refer servicing to your dealer  
or to qualified service personnel.  
4. Never face the camera towards the sun or any bright or  
reflective light. This may cause smear on the picture and  
possible damage to the CCD.  
5. Do not remove the serial sticker for the warranty service.  
All-pole power switch - Incorporate an all-pole power switch,  
with a contact separation of at least 3 mm in each pole, into the  
electrical installation of the building. If it is needed to open the  
housing for servicing and/or other activities, use this all-pole  
switch as the main disconnect device for switching off the  
voltage to the unit.  
Camera grounding - For mounting the camera in potentially  
damp environments, ensure to ground the system using the  
ground connection of the power supply connector (see section:  
Connecting external power supply).  
Camera lens - An assembled camera lens in the outdoor  
housing must comply and be tested in accordance with UL/  
IEC60065. Any output or signal lines from the camera must be  
SELV or Limited Power Source. For safety reasons, the  
environmental specification of the camera lens assembly must  
be within the environmental specification of -10 °C (14 °F) to  
50 °C (122 °F).  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
en | Safety  
VEZ-400 Mini PTZ Dome  
Camera signal - Protect the cable with a primary protector if  
the camera signal is beyond 140 feet, in accordance with  
NEC800 (CEC Section 60).  
Coax grounding:  
Ground the cable system if connecting an outside cable  
system to the unit.  
Connect outdoor equipment to the unit's inputs only after  
this unit has had its grounding plug connected to a  
grounded outlet or its ground terminal is properly  
connected to a ground source.  
Disconnect the unit's input connectors from outdoor  
equipment before disconnecting the grounding plug or  
grounding terminal.  
Follow proper safety precautions such as grounding for  
any outdoor device connected to this unit.  
U.S.A. models only - Section 810 of the National Electrical Code,  
ANSI/NFPA No.70 provides information regarding proper  
grounding of the mount and supporting structure, grounding of  
the coax to a discharge unit, size of grounding conductors,  
location of discharge unit, connection to grounding electrodes,  
and requirements for the grounding electrode.  
Disposal - Your Bosch product was developed and  
manufactured with high-quality material and components that  
can be recycled and reused. This symbol means that electronic  
and electrical appliances, which have reached the end of their  
working life, must be collected and disposed of separately  
from household waste material. Separate collecting systems  
are usually in place for disused electronic and electrical  
products. Please dispose of these units at an environmentally  
compatible recycling facility, per European Directive 2002/96/  
EC.  
Electronic Surveillance - This device is intended for use in  
public areas only. U.S. federal law strictly prohibits  
surreptitious recording of oral communications.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Safety | en  
9
Environmental statement - Bosch has a strong commitment  
towards the environment. This unit has been designed to  
respect the environment as much as possible.  
Electrostatic-sensitive device - Use proper CMOS/MOS-FET  
handling precautions to avoid electrostatic discharge.  
NOTE: Wear required grounded wrist straps and observe proper  
ESD safety precautions when handling the electrostatic-  
sensitive printed circuit boards.  
Fuse rating - For protection of the device, the branch circuit  
protection must be secured with a maximum fuse rating of 16A.  
This must be in accordance with NEC800 (CEC Section 60).  
Moving - Disconnect the power before moving the unit. Move  
the unit with care. Excessive force or shock may damage the  
unit and the hard disk drives.  
Outdoor signals - The installation for outdoor signals, especially  
regarding clearance from power and lightning conductors and  
transient protection, must be in accordance with NEC725 and  
NEC800 (CEC Rule 16-224 and CEC Section 60).  
Permanently connected equipment - Incorporate a readily-  
accessible disconnect device in the building installation wiring.  
Pluggable equipment - Install the socket outlet near the  
equipment so that it is easily accessible.  
Power resupply - If the unit is forced to power down due to  
exceeding the specified operating temperatures, disconnect  
the power cord, wait for at least 30 seconds, and then  
reconnect the power cord.  
Power lines: Do not locate the camera near overhead power  
lines, power circuits, or electrical lights, nor where it may  
contact such power lines, circuits, or lights.  
Rack mount  
Ventilation - Do not place this unit in a built-in installation  
or rack without proper ventilation or adhering to the  
manufacturer’s instructions. The equipment must not  
exceed its maximum operating temperature requirements.  
Mechanical loading - Properly mount the equipment in a  
rack to prevent a hazardous condition due to uneven  
mechanical loading.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 en | Safety  
VEZ-400 Mini PTZ Dome  
SELV - All the input/output ports are Safety Extra Low Voltage  
(SELV) circuits. SELV circuits should only be connected to  
other SELV circuits.  
Because the ISDN circuits are treated like telephone-network  
voltage, avoid connecting the SELV circuit to the Telephone  
Network Voltage (TNV) circuits.  
The system ground is only used to comply with safety standards  
or installation practices in certain countries. Bosch does not  
recommend connecting system ground to safety ground unless  
it is explicitly required. However, if the system ground and  
safety ground are connected and grounding loops are causing  
interference in the video signal, use an isolation transformer  
(available separately from Bosch).  
CAUTION!  
Connecting System ground to Safety ground may result in  
ground loops that can disrupt the CCTV system.  
Video loss - Video loss is inherent to digital video recording;  
therefore, Bosch Security Systems cannot be held liable for any  
damage that results from missing video information. To  
minimize the risk of lost digital information, Bosch Security  
Systems recommends multiple, redundant recording systems,  
and a procedure to back up all analog and digital information.  
1.4  
FCC & ICES compliance  
FCC & ICES Information  
(U.S.A. and Canadian Models Only)  
This device complies with part 15 of the FCC Rules. Operation is  
subject to the following conditions:  
this device may not cause harmful interference, and  
this device must accept any interference received,  
including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the  
limits for a Class A digital device, pursuant to Part 15 of the  
FCC Rules and ICES-003 of Industry Canada. These limits are  
designed to provide reasonable protection against harmful  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Safety | en 11  
interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and radiates  
radio frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular  
installation. In a domestic environment, this product may cause  
radio interference, in which case the user may be required to  
take adequate measures. If this equipment does cause harmful  
interference to radio or television reception, which may be  
determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of  
the following measures:  
reorient or relocate the receiving antenna;  
increase the separation between the equipment and  
receiver;  
connect the equipment into an outlet on a circuit different  
from that to which the receiver is connected;  
consult the dealer or an experienced radio/TV technician  
for help.  
Intentional or unintentional modifications, not expressly  
approved by the party responsible for compliance, shall not be  
made. Any such modifications could void the user's authority to  
operate the equipment. If necessary, the user should consult  
the dealer or an experienced radio/television technician for  
corrective action.  
The user may find the following booklet, prepared by the  
Federal Communications Commission, helpful: How to Identify  
and Resolve Radio-TV Interference Problems. This booklet is  
available from the U.S. Government Printing Office,  
Washington, DC 20402, Stock No. 004-000-00345-4.  
Informations FCC et ICES  
(modèles utilisés aux États-Unis et au Canada uniquement)  
Ce produit est conforme aux normes FCC partie 15. la mise en  
service est soumises aux deux conditions suivantes :  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12 en | Safety  
VEZ-400 Mini PTZ Dome  
cet appareil ne peut pas provoquer d'interférence nuisible  
et  
cet appareil doit pouvoir tolérer toutes les interférences  
auxquelles il est soumit, y compris les interférences qui  
pourraient influer sur son bon fonctionnement.  
Suite à différents tests, cet appareil s’est révélé conforme aux  
exigences imposées aux appareils numériques de Classe A en  
vertu de la section 15 du règlement de la Commission fédérale  
des communications des États-Unis (FCC), et en vertu de la  
norme ICES-003 d’Industrie Canada. Ces cexigences visent à  
fournir une protection raisonnable contre les interférences  
nuisibles quand l'appareil est utilisé dans un environment  
commercial. Cet appareil génère, utilise et émet de l'energie de  
fréquence radio, et peut, en cas d'installation ou d'utilisation  
non conforme aux instructions, engendrer des interférences  
nuisibles aux radiocommunications. Toutefois, rien ne garantit  
l'absence d'interférences dans une installation particulière.  
L’utilisation de ce produit dans une zone résidentielle peut  
provoquer des interférences nuisibles. Le cas échéant,  
l’utilisateur devra remédier à ces interférences à ses propres  
frais. Il est possible de déterminer la production d'interférences  
en mettant l'appareil successivement hors et sous tension, tout  
en contrôlant la réception radio ou télévision. L'utilisateur peut  
parvenir à éliminer les interférences éventuelles en prenant une  
ou plusieurs des mesures suivantes:  
Modifier l'orientation ou l'emplacement de l'antenne  
réceptrice;  
Éloigner l'appareil du récepteur;  
Brancher l'appareil sur une prise située sur un circuit  
différent de celui du récepteur;  
Consulter le revendeur ou un technicien qualifié en radio/  
télévision pour obtenir de l'aide.  
Toute modification apportée au produit, non expressément  
approuvée par la partie responsable de l'appareil, est  
strictement interdite. Une telle modification est susceptible  
d'entraîner la révocation du droit d'utilisation de l'appareil.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Safety | en 13  
Au besoin, l’utilisateur consultera son revendeur ou un  
technicien qualifié en radio/télévision, qui procédera à une  
opération corrective.  
La brochure suivante, publiée par la Commission fédérale des  
communications (FCC), peut s’avérer utile : How to Identify and  
Resolve Radio-TV Interference Problems (Comment identifier et  
résoudre les problèmes d’interférences de radio et de  
télévision). Cette brochure est disponible auprès du U.S.  
Government Printing Office, Washington, DC 20402, États-Unis,  
sous la référence n° 004-000-00345-4.  
1.5  
Bosch notices  
DANGER!  
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE  
COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE.  
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.  
CAUTION!  
This is a Class A product. In a domestic environment, this  
product may cause radio interference, in which case the user  
may be required to take adequate measures.  
Disclaimer  
Underwriter Laboratories Inc. ("UL") has not tested the  
performance or reliability of the security or signaling aspects of  
this product. UL has only tested fire, shock and/or casualty  
hazards as outlined in UL’s Standard(s) for Safety for Audio,  
Video and Similar Electronic Apparatus - Safety Requirements  
(UL 60065). UL Certification does not cover the performance or  
reliability of the security or signaling aspects of this product.  
UL MAKES NO REPRESENTATIONS, WARRANTIES, OR  
CERTIFICATIONS WHATSOEVER REGARDING THE  
PERFORMANCE OR RELIABILITY OF ANY SECURITY- OR  
SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14 en | Safety  
VEZ-400 Mini PTZ Dome  
Copyright  
This manual is the intellectual property of Bosch Security  
Systems and is protected by copyright. All rights reserved.  
Trademarks  
All hardware and software product names used in this  
document are likely to be registered trademarks and must be  
treated accordingly.  
Note:  
This manual has been compiled with great care and the  
information it contains has been verified thoroughly. The text  
was complete and correct at the time of printing. The ongoing  
development of products means that the content can change  
without notice. Bosch Security Systems accepts no liability for  
damage resulting directly or indirectly from faults,  
incompleteness or discrepancies between this manual and the  
product described.  
More information  
For more information please contact the nearest Bosch Security  
Systems location or visit www.boschsecurity.com  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Description | en 15  
2
Description  
This manual is a reference for programming and operating the  
VEZ-400 Mini PTZ Dome camera. It contains information about  
features, commands, and operation methods.  
The VEZ-400 Mini PTZ Dome is an autofocus, high-resolution,  
integrated day/night camera that is part of a larger building  
block for any surveillance/security system. By using multiple  
keyboard controllers and multiple dome cameras, no place is  
too large for monitoring. Extensible andflexible architecture  
facilitates remote control functions for a variety of external  
switching devices, such as DVRs.  
2.1  
Features  
260X Zoom (26X Effective Optical Zoom, 10X Digital)  
Wide Dynamic Range (WDR)  
Day & Night (Auto/BW/Color)  
Pan 360° Endless Rotation  
Tilt 180° Vector scan (90° when 3D Privacy Masking is  
enabled)  
99/210 Preset Positions (except Short-cut command)  
2/8 Auto scans  
2/8 Patterns  
2/8 Tours (consisting of Presets, Patterns, and Scans)  
4 Alarm inputs, 1 Alarm output (Off/N.C./N.O.)  
Programmable PTZ Speed: Proportional to Zoom ratio,  
changeable preset speed  
OSD with multiple display languages  
Privacy mask zones  
NOTICE!  
The VEZ-400 Mini PTZ Dome uses a 30X zoom lens (fW=3.49  
0.17mm fT=104.02 5.20mm). The polycarbonate bubble (part  
of the camera housing) causes image distortion, reducing the  
optical zoom performance. The effective optical zoom ratio is  
26X +/- 10%.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16 en | Unpacking  
VEZ-400 Mini PTZ Dome  
3
Unpacking  
This equipment should be unpacked and handled with care. If  
an item appears to have been damaged in shipment, notify the  
shipper immediately.  
The original packing carton is the safest container in which to  
transport the unit and must be used to return the unit for  
service. Save it for possible future use.  
Verify that all the parts listed in the Parts List are included. If  
any items are missing, notify your Bosch Security Systems Sales  
or Customer Service Representative.  
3.1  
Parts List  
Qty Description  
1
VEZ-400 Mini PTZ Dome camera  
1
Drilling Template  
4
4
4
1
6 x 30 mm plastic anchors  
#8 x 32 screws and attached O-rings  
M4 x 12 Torx screws and attached O-rings  
T20 Security Torx wrench  
1
User Manual (this booklet)  
WARNING!  
Make sure that appropriate mounting screws, rubber O-rings,  
and anchors are used for the surface to which the camera is  
mounted. The supplied plastic anchors and mounting screws  
are only suitable for mounting the camera on a concrete ceiling.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Unpacking | en 17  
3.2  
Additional Tools Required  
No. 2 Phillips screwdriver  
Drill with appropriate bit for pre-drilling anchor holes  
Appropriate tool for cutting a hole in drywall or ceiling tile  
(if applicable)  
3.3  
Accessories  
The following accessories are available for the camera:  
Model Number Description  
VEZ-A4-IC VEZ-400 In-ceiling Mount  
Drawing  
(Charcoal color and  
white color ceiling plate  
included)  
VEZ-A4-PC  
VEZ-400 Pipe mount  
(Charcoal color)  
VEZ-400 Pipe mount  
(White color)  
VEZ-A4-PW  
VEZ-A4-WC  
VEZ-400 Wall mount  
(Charcoal color)  
VEZ-A4-WW  
VEZ-400 Wall mount  
(White color)  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18 en | Installation Overview  
VEZ-400 Mini PTZ Dome  
4
Installation Overview  
The VEZ-400 Mini PTZ Dome camera comes with the hardware  
and installation instructions necessary to mount the camera to  
a ceiling.  
This following mounting accessories are available (and are  
supplied with separate mounting instructions):  
Wall mount, used in applications where the camera is  
mounted to a vertical wall.  
Pipe mount, used in applications where the camera is  
mounted to a horizontal (high) ceiling.  
In-ceiling mount, used in applications where the camera is  
mounted into a recessed ceiling.  
The installation should be made by qualified installation  
personnel and conform to the National Electrical Code and  
applicable local codes.  
DANGER!  
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT  
PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN  
THE OPERATING INSTRUCTIONS, UNLESS YOU ARE QUALIFIED  
TO DO SO.  
In USA and Canada, use Class 2 power supply unit (PSU) only.  
NOTICE!  
A grounded conduit is required in order to meet the EMC  
Regulation Requirements.  
NOTICE!  
The 60cm/23.5" cable attached to the VEZ-400 Mini PTZ Dome  
camera is designed to make the necessary cable connections  
outside of the camera in a junction box (not included).  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Installing a Surface Mount | en 19  
5
Installing a Surface Mount  
Use the following illustration as a guide for installing the  
camera directly onto the ceiling (surface mount):  
Figure 5.1 Mounting diagram  
Number Description  
1
2
3
4
5
6
Drilling template  
6 x 30 mm plastic anchor  
Camera base  
O-ring  
#8 x 32 screw  
Safety strap  
(will hold item #7 dome cover for easy installation)  
Dome cover  
M4 x 12 Torx screw  
7
8
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20 en | Installing a Surface Mount  
VEZ-400 Mini PTZ Dome  
CAUTION!  
To prevent humidity problems, the camera must be installed in  
dry conditions, and the cable leads should be sealed after they  
are connected.  
1. Determine a secure location that can support the weight of  
the dome.  
2. Use the template (refer to Figure 6.1, item 1) to mark the  
locations of the four screw holes and the cable conduit.  
3. Pre-drill the four screw holes wide enough to accept the  
plastic anchors.  
4. Cut out the entire cable conduit hole.  
5. Insert the four plastic anchors (item 2) inside the pre-  
drilled holes.  
6. Route the cables from the camera through the conduit in  
the ceiling.  
7. Remove the dome cover (item 6) from the camera base  
(item 3).  
NOTICE!  
To prevent scratches on the dome cover, Do Not Remove the  
plastic film protecting the dome cover until after hardware  
installation is complete.  
8. Remove the white foam ring from the camera base, and  
remove the white foam sheet from the inside of the dome  
cover. (These are for protection during transport.)  
9. Align the four screw holes on the camera base (item 3)  
with the four plastic anchors.  
CAUTION!  
When (re)mounting the camera base, make sure that each  
mounting screw has a rubber O-ring. This ensures protection  
against water ingress.  
10. Attach the camera base to the ceiling using the four #8 x  
32 screws (with O-rings attached) (item 4). Tighten the  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Installing a Surface Mount | en 21  
screws enough to ensure that the camera base is secured  
to the ceiling.  
11. Make the necessary Dip Switch settings (described in  
chapter 4.3). Note: This step can also be done later, but  
then the dome cover must be re-opened.  
CAUTION!  
When (re)mounting the dome cover to the camera base, make  
sure that each screw has a rubber O-ring, and that the large  
rubber O-ring is in place on the camera base. This ensures  
protection against water ingress.  
12. Align the screw holes on the dome cover (item 6) with the  
camera base.  
13. Attach the dome cover to the camera base using the four  
M4 x 12 Torx screws (with O-rings (item 4) attached) using  
the supplied Torx wrench. Make sure that the large rubber  
O-ring between the camera base and dome cover is in  
place to protect the camera against water ingress. Tighten  
the screws enough to ensure that the housing is secured to  
the camera base and that the rubber O-rings seal the dome  
cover against water ingress.  
14. Remove the plastic film protecting the dome cover from  
scratches.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22 en | Connection  
VEZ-400 Mini PTZ Dome  
6
Connection  
After the camera is mounted, connect the video, control, and  
power cables.  
CAUTION!  
Do not connect power to the camera until all other connections  
are made.  
CAUTION!  
Installation should only be performed by qualified service  
personnel in accordance with the National Electrical Code or  
applicable local codes.  
CAUTION!  
All wires for installation applications must be routed through a  
grounded conduit.  
CAUTION!  
To prevent humidity problems, the camera must be installed in  
dry conditions, and the cable leads should be sealed once  
connected.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Connection | en 23  
Use the following illustration as a guide for preparing and  
connecting the wiring:  
Figure 6.1 Typical wiring configuration  
1 24 VAC Power In  
2 Power connector with screw terminals  
3 Power adapter (supplied separately) (24 VAC, Peak 2.5 A)  
4 8-pin I/O terminal (Alarm In/Out)  
5 2-pin data terminal (RS-485 Connection)  
6 Video Out (Female BNC connector)  
7 Video In to monitor (Male BNC connector)  
8 CCTV Monitor  
9 Bosch keyboard controller  
Note: The box around several objects in the graphic above  
indicates that those devices are supplied separately.  
6.1  
RS-485 Connections  
The camera can be controlled by an external device or control  
system using an RS-485 duplexer. The total length of the cable  
for communication should not exceed 1 km (3937 ft). If the  
distance between the camera and the control room is greater  
than 1 km (3937 ft), Bosch recommends using a repeater (not  
supplied).  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
24 en | Connection  
VEZ-400 Mini PTZ Dome  
NOTICE!  
The wire shield must be tied to signal at both ends, if 2-wire  
twisted pair is used.  
NOTICE!  
When the RS-485 signal is looped through, ensure that (only)  
the last device is terminated properly. Improper RS-485 wiring  
or termination may result in unreliable system operation.  
Use a 2-wire (shielded), half-duplex, differential, multi-drop  
with the following attributes:  
Wire Type  
Distance  
Gauge  
2-wire Shielded Twisted Pair  
1.2 Km (3937 ft)  
0.511 mm (24 AWG)  
120 Ω  
Impedance  
Table 6.1 RS-485 Wire Specifications  
The following table shows the terminal connections for the 2-  
pin terminal block RS-485 connections (see Figure 6.1, item 5):  
Number Signal  
Color  
Sky  
White  
1
2
TRX +  
TRX -  
Table 6.2 2-pin Terminal Block Connections  
NOTICE!  
When the camera's RS-485 port is connected to a MIC-BP3  
Biphase convertor, the camera's TRX+ should be connected to  
the convertor's RxB, and TRX- should be connected to RxA. The  
camera's baud rate should be set to 9600, and the protocol  
should be set to Bosch OSRD. Also make sure that the camera  
ID is configured correctly. For further details on setting up the  
MIC-BP3, please refer to the separate MIC-BP3 Bi-Phase  
Converter Card Installation and Operation Manual.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Connection | en 25  
6.2  
Video Connection  
Coaxial cable terminated with a male BNC connector is the  
most common method for transmitting composite video from  
the camera to a monitor. If the head end device features built in  
video termination then no termination connector is needed.  
Size  
O.D. between 4.6 mm (0.181 in.) and  
7.9 mm (0.312 in.)  
Copper braid: 95%  
Shield  
Central Conductor Standard copper center  
Terminal Connector Male BNC  
Table 6.3 Recommended Coax Specifications  
Connecting the Video  
To connect the video, do the following:  
1. Terminate the coaxial cable from the head end system with  
a male BNC connector. Alternately, switch the head end  
system to 75 Ohm termination.  
2. Connect the male BNC connector to the Video Out female  
BNC connector from the base of the camera.  
6.3  
Alarm Connections  
The camera provides four alarm inputs and one alarm output.  
Each input can be activated by dry contact devices such as  
pressure pads, passive infrared detectors, door contacts, and  
similar devices. The alarm output can activate an external  
device, such as a buzzer.  
Wire alarms either Normally Open (N.O.) or Normally Closed  
(N.C.); you must program the alarm inputs N.O. (the default) or  
N.C. through the on-screen display menus.  
The following table summarizes the maximum distances for  
alarm wires:  
Wire Size Maximum Distance  
AWG mm Meters  
Feet  
22  
18  
0.644 500  
1.024 800  
152.4  
243.8  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
26 en | Connection  
VEZ-400 Mini PTZ Dome  
Connecting the Alarms  
Use the following table to connect alarm wires to the 8-pin  
terminal block from the camera:  
Number  
Signal  
Color  
1
2
3
4
5
6
7
8
NC  
Yellow  
COM Orange  
NO  
AL3  
Green  
Blue  
GND ALM Black  
AL2  
AL1  
AL0  
Violet  
Gray  
Brown  
Table 6.4 8-pin Terminal Block Connections  
6.4  
Power Connections  
CAUTION!  
The camera unit accepts 24 VAC power only. Do not connect  
120 V or 230 V to this camera!  
The recommended power cable is a 2-conductor, 14-18 gauge  
cable, depending on the distance.  
A/W  
14 AWG 16AWG 18 AWG  
(2.5 mm) (1.5 mm) (1.0 mm)  
2 A / 43 W (with heater) 250 m  
150 m  
100 m  
(820 ft)  
(492 ft)  
(328 ft)  
6.5  
Camera Settings  
The camera can communicate with external switching devices  
such as a multiplexer or a DVR by setting the Rotary and Dip  
switches. Refer to the tables below for setting the camera’s ID  
and selecting the protocol. The camera's Dip switches can be  
accessed by removing the dome cover, and are located on a  
PCB attached to the camera base.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Connection | en 27  
CAUTION!  
To prevent humidity problems, the camera’s dome cover must  
be removed only in dry conditions.  
CAUTION!  
When (re)mounting the dome cover to the camera base, ensure  
that each screw has a rubber O-ring, and that the large rubber  
O-ring is in place on the camera base. This ensures protection  
against water ingress.  
Figure 6.2 Dome Camera Switches  
Number Description  
1
2
3
SW301 Rotary switch  
SW303 Dip switches  
SW302 Rotary switch  
Figure 6.3 Close-up of Rotary Switches and Dip Switches  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
28 en | Connection  
VEZ-400 Mini PTZ Dome  
6.5.1  
Setting the address (ID) of the camera  
To prevent faulty operations and malfunctions, each camera  
must have an unique address (ID). The default setting is  
0[ID001].  
X0  
X1  
SW301 SW302  
Table 6.5 Dome Camera ID Setting (Rotary Switches SW301, SW302)  
6.5.2  
Setting the protocol of the camera  
Set the protocol setting, the baud rate, and the termination  
setting of dip switch SW303, using the data in the tables below.  
Note: The value marked * is the default setting.  
No1 No2 Protocol  
Off On Bosch OSRD*  
Off Off Pelco-D/Pelco-P  
Table 6.6 Camera Protocol Setting (No. 1 & 2, Dip Switch SW303)  
No3 No4 Baud Rate (bps)  
Off Off 2400  
Off On 4800  
On Off 9600*  
On On 38400  
Table 6.7 Camera Baud Rate Setting (No. 3 & 4, Dip Switch SW303)  
No5 Termination  
Off Off  
On On*  
Table 6.8 Camera’s RS-485 Termination Setting (No. 5, Dip Switch  
SW303)  
NOTICE!  
When the RS-485 signal is looped through, make sure that  
(only) the last device is properly terminated. Improper RS-485  
wiring or termination may result in unreliable system operation.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 29  
7
On-Screen Display (OSD) Menu  
NOTICE!  
Before beginning this section of the manual, you must install  
and connect the camera to an interface device. Refer to the  
Mounting Manual. Once you have installed the camera, apply  
power to the camera.  
When the camera is powered-up, the start-up screen appears  
on the monitor.  
VEZ-400 MINI PTZ DOME  
RS-485/9600  
ID001  
CAM TEST ...PASS  
7.1  
Basic Navigation and Common Actions  
Camera operators can operate the camera by two methods:  
Use of hot keys [Refer to Section 11 Bosch Protocol,  
page 63].  
Use of the OSD Menu displayed on the monitor [Continue  
to read this chapter].  
The following table identifies the symbols that depict actions of  
the joystick controller, or the keys on the keyboard, that control  
the camera.  
NOTICE!  
The step-by-step instructions in this chapter are written with  
the idea that camera operators know the joystick/keyboard  
commands (listed in the table below) for actions (Select, Clear,  
Save, Exit).  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
Command  
Action  
Move the joystick up to select an item.  
Move the joystick down to select an item.  
Move the joystick left to select options for  
an item.  
Move the joystick right to select options for  
an item.  
/ [Open] button Move the joystick right to select, change, or  
/ [Near] button save values, or to go to edit pages.  
/ [Close] button Move the joystick right to cancel or to exit  
/ [Far] button  
the current menu. (Return to the previous  
menu without saving.)  
Turn the joystick clockwise (zoom tele).  
Turn the joystick counterclockwise (zoom  
wide).  
[KEY]  
Press the defined key.  
In Bosch protocol: Stop an action;  
Aux code;  
camera switches to manual mode and  
In Pelco protocol: pauses temporarily.  
96 + Preset or ESC  
button  
NOTICE!  
You must save each state after each step of the submenu or  
the edit menu upon editing functions or changing settings.  
You may need to save settings for one function twice. For  
example, after {the position or the title of a Preset} is saved at  
the ‘Sub Menu’, {the status of the Preset Setup} must be saved  
at the ‘Preset Setup Menu’ again.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 31  
7.2  
Main Menu  
The MAIN MENU provides access to all programmable settings  
for the camera.  
When you use Pelco-D and Pelco-P protocol with your  
controller, you can access the MAIN MENU on your monitor by  
pressing the keys [95] + [Preset], or by pressing and holding  
the [Menu] key for 2 seconds.  
When you use Bosch OSRD protocol with your controller, you  
can access the MAIN MENU on your monitor by pressing the  
keys [ON]+[46]+[Enter].  
MAIN MENU  
SYSTEM SETUP  
DISPLAY SETUP  
CAMERA SETUP  
DOME MOTION  
PRESET SETUP  
PATTERN SETUP  
TOUR SETUP  
SCAN SETUP  
ALARM SETUP  
EXIT  
MAIN MENU Choices  
Menu  
Description  
SYSTEM SETUP Accesses system information and actions  
such as: rebooting, resetting default settings,  
setting or resetting passwords.  
DISPLAY SETUP Accesses adjustable display settings such as:  
OSD, privacy zone masking, image setup,  
motion/face detection, and display language.  
CAMERA SETUP Accesses adjustable camera settings such as:  
focus/zoom, white balance, exposure, day/  
night, sharpness and backlight, WDR/DNR.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
32 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
Menu  
Description  
DOME MOTION Accesses adjustable pan/tilt/zoom (PTZ)  
settings such as: preset speed, autoflip,  
proportional pan/tilt, home preset, and  
calibration.  
PRESET SETUP Accesses preset setup.  
PATTERN SETUP Accesses pattern setup.  
TOUR SETUP  
SCAN SETUP  
Accesses tour setup.  
Accesses scan setup.  
ALARM SETUP Accesses the alarm settings such as: inputs,  
outputs, and rules.  
EXIT  
Exits the menu.  
7.2.1  
Editing Titles  
To edit the title of a function (preset, pattern, tour, scan):  
1. From the MAIN MENU, move the joystick to the right  
(setup menu of preset, pattern, tour, and scan). Move the  
joystick to the right again to select the Title menu. The  
screen TITLE appears.  
TITLE  
ABCDEFGHIJKLMNOPQRSTUVWXYZ01  
23456789/+-=;?#.,"~0  
SELECT: (MOVE)  
SET/CLEAR: (TELE/WIDE)  
SAVE: (NEAR)  
EXIT: (FAR)  
2. Move the joystick right, left, up, or down to select a  
character.  
3. Press the button [Tele] to input a character.  
Note: To cancel a character, press the [Wide] button.  
4. When you finish entering the title, save the title.  
Note: To cancel the selected title, use the [Far] button to  
return to the previous menu.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 33  
7.2.2  
Clearing Saved Functions  
To clear (delete) individual, saved functions:  
1. Select a function in any menu (PRESET/TOUR/PATTERN/  
SCAN/ALARM).  
2. Move the joystick right. Select Clear.  
3. If necessary, follow additional prompts.  
4. Save the settings.  
7.3  
System Setup Menu  
SYSTEM SETUP  
INFO.  
REBOOT  
INITIALIZE  
PROTOCOL LOG  
PASSWORD  
EXIT  
5.1  
From this menu, you can display system information, reboot the  
system, restore default settings (initialize), and set a password.  
7.3.1  
System Information  
System Information displays details about the Model Name/  
Running Version/Protocol/Communication Type/Camera ID No./  
System. It is only for reference; you cannot make changes here.  
To display the System Information screen:  
1. From the MAIN MENU, select SYSTEM SETUP. The  
submenu SYSTEM SETUP appears.  
2. Select INFO.. The screen SYSTEM INFORMATION  
appears.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
SYSTEM INFORMATION  
VEZ-400 MINI PTZ DOME  
VEZ4 SPD V1.0.0  
VEZ4 CAM V1.0.0  
RS485/9600  
ID001  
PAL  
-Exit: (FAR)  
3. Note the system information displayed.  
Note: The camera ID changes depending on settings.  
7.3.2  
Reboot  
Reboot the system if there are any problems with controlling or  
operating the camera. Rebooting will recycle power without  
changing camera settings. To reboot the system:  
1. From the MAIN MENU, select SYSTEM SETUP. The  
submenu SYSTEM SETUP appears.  
2. Select REBOOT. The screen REBOOT appears.  
REBOOT  
CONTINUE?  
YES: NEAR  
NO: FAR  
3. Select the option "Yes."  
4. Select the value "Near." The system reboots.  
7.3.3  
Initialize  
Initialize the system to restore some or all of the camera  
settings to their defaults. To initialize:  
1. From the MAIN MENU, select SYSTEM SETUP. The  
submenu SYSTEM SETUP appears.  
2. Select INITIALIZE. The screen INITIALIZE appears.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 35  
INITIALIZE  
ALL  
CAM  
PRESET  
TOUR  
PATTERN  
SCAN  
ETC  
SAVE  
BACK  
3. Select the function to initialize:  
ALL: Clear All items saved in the system.  
CAM: Clear camera-related settings.  
PRESET: Clear all saved presets. (To clear presets  
individually, refer to Section 7.7 Preset Setup,  
page 52.)  
TOUR: Clear saved Tours.  
PATTERN: Clear saved Patterns.  
SCAN: Clear saved Scan items.  
[ETC: Clear other settings except camera and PTZ  
settings (CAM status and saved PRESET, TOUR,  
PATTERN and SCAN).]  
4. Select the value "Clear."  
5. Save. The system restores the default settings of the  
camera.  
7.3.4  
Password  
Set a four-character password to prevent unauthorized access  
and changes to the camera settings. Users/operators must  
enter the valid password before programming the camera. The  
default password is "0000." To set/enable a password:  
1. From the MAIN MENU, select SYSTEM SETUP. The  
submenu SYSTEM SETUP appears.  
2. Select PASSWORD. The screen PASSWORD appears.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
36 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
PASSWORD  
CURRENT  
ENABLE  
NEW  
CONFIRM  
0123456789  
-SET/CLEAR  
-EXIT  
3. Select the numbers that comprise the password.  
4. Press the key {Tele}.  
5. Select the option "Enable."  
6. Select the value "Enable." The system locks the password.  
7.4  
Display Setup  
DISPLAY SETUP  
OSD SETUP  
PRIVACY ZONE  
IMAGE SETUP  
MOTION/FACE  
LANGUAGE: [language]  
EXIT  
From this menu, you can set up the on-screen display, create/  
edit/ delete a privacy mask, change displayed image settings,  
set motion/face detection, and change the display language.  
7.4.1  
OSD Setup  
OSD Setup allows you to program how labels are displayed on  
the monitor and where on your monitor you want to display  
each label. To set up the on-screen display:  
1. From the MAIN MENU, select DISPLAY SETUP. The  
submenu DISPLAY SETUP appears.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 37  
2. Select OSD SETUP. The screen OSD SETUP appears.  
OSD SETUP  
LABEL POSITION  
TIME  
ZOOM  
ID  
MODE  
ANGLE  
SAVE  
BACK  
- CHANGE  
- TO SETUP  
3. Select the option "Label Position" to set/change the  
position of labels.  
4. Select the value "On" to display the label position.  
5. Press the button {Tele} to edit the position of labels.  
6. Use the joystick to move the label up, down, left, and/or  
right.  
7. Save the option.  
8. Select any of the following labels to display:  
Title (Label Position)  
(Dwell) Time  
Zoom (ratio)  
(Camera) ID  
(Operation) Mode  
(PTZ) Angle  
Note: You can display only selected video or characters in  
the video. Each element may be configured.  
9. Save the option.  
7.4.2  
Privacy Zone  
A Privacy mask zone allows an administrator to program a four-  
sided, user-defined zone which cannot be viewed by operators.  
A maximum of 15 positions can be displayed on the monitor.  
The mask will stay in position even with changing pan and tilt  
angles, and will adjust in size according to the zoom ratio [Tele/  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
38 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
Wide]. Bosch recommends setting the size of the mask to be at  
least twice the size (height and width) of the object being  
masked. The speed of displaying masks is proportional to the  
number of masks on the screen. To set a privacy mask zone:  
1. From the MAIN MENU, select DISPLAY SETUP. The  
submenu DISPLAY SETUP appears.  
2. Select PRIVACY ZONE. The screen PRIVACY ZONE SETUP  
appears.  
PRIVACY ZONE SETUP  
PRIVACY.##  
EDIT  
DISPLAY  
WIDTH  
HEIGHT  
CLEAR  
SAVE  
BACK  
- CHANGE  
3. Select the option "Privacy."  
4. Select a zone ID [00-14).  
5. Select the option "Edit."  
6. Select the value "Mask."  
7. Move to a target (Pan/Tilt) and adjust a Mask using the  
joystick (Pan/Tilt, Zoom Tele or Wide).  
8. Save the position.  
9. Exit the menu Edit.  
10. Select the option "Display."  
11. Select the value "On." The mask appears.  
12. Select a position.  
13. Select the height (XX) and width (XX) of the mask (1~5X)  
to resize the mask.  
14. Save the settings.  
Note: Select the option "Clear" to clear the Mask.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 39  
7.4.3  
Image Setup  
This menu is for changing displayed image settings. To set up  
image setup:  
1. From the MAIN MENU, select DISPLAY SETUP. The  
submenu DISPLAY SETUP appears.  
2. Select IMAGE SETUP. The screen IMAGE SETUP appears.  
IMAGE SETUP  
MIRROR  
SAVE  
BACK  
3. Select the option "Mirror."  
4. Select the desired value for the image.  
Normal  
Horizontal  
Vertical  
H/V [Horizontal/Vertical]  
5. Select the desired value  
6. Save the settings.  
7.4.4  
Motion/Face Detection  
Program the camera to monitor the movements of the image  
and send an alarm message to the OSD in the Alarm Out action.  
To set up motion/face detection:  
1. From the MAIN MENU, select DISPLAY SETUP. The  
submenu DISPLAY SETUP appears.  
2. Select MOTION/FACE. The screen MOTION/FACE  
DETECTION appears.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
40 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
MOTION/FACE DETECTION  
MD/FD  
SENSITIVITY  
ALARM  
ATIME  
SAVE  
BACK  
3. Select the option "MD/FD" to program motion detection  
and/or face detection.  
4. Select the appropriate value:  
Off  
MD  
FD  
5. Select the option "Sensitivity."  
6. Select the appropriate value.  
7. Select the option "Alarm."  
8. Select the appropriate value:  
OSD  
Alarm Out  
Both  
9. Save the settings.  
7.4.5  
Language  
To select a different display language:  
1. From the MAIN MENU, select DISPLAY SETUP. The  
submenu DISPLAY SETUP appears.  
2. Select LANGUAGE. The screen LANGUAGE appears.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 41  
3. Select the desired language:  
English  
Chinese  
Dutch  
French  
German  
Italian  
Russian  
Spanish  
7.5  
Camera Setup  
CAMERA SETUP  
FOCUS/ZOOM  
W-BALANCE  
EXPOSURE  
DAY/NIGHT  
ADVANCED  
WDR/DNR  
EXIT  
From this menu, you can set the focus/zoom, white balance,  
auto exposure, day/night, the WDR/DNR settings, and  
Advanced settings.  
7.5.1  
Focus/Zoom  
Auto Focus allows the lens to remain in focus during zoom-in,  
zoom-out and motion functions automatically. Zoom speed  
allows the user to define how fast the camera will go from full  
wide zoom to the 30X optical zoom. To set focus/zoom settings:  
1. From the MAIN MENU, select CAMERA SETUP. The  
submenu CAMERA SETUP appears.  
2. Select FOCUS/ZOOM. The screen FOCUS/ZOOM SETUP  
appears.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
42 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
FOCUS/ZOOM SETUP  
FOCUS  
ZOOM SPD  
D.ZOOM  
SAVE  
BACK  
3. Select the option "Focus."  
4. Select the appropriate value:  
Auto  
Manual  
Semi-Auto  
5. Select the option "Zoom Spd" to set the zoom speed.  
6. Select the appropriate value:  
Slow  
Normal  
Fast  
V-Fast  
7. Select the option "D.Zoom" to set the Digital Zoom.  
8. Select the appropriate value: ON or OFF.  
9. Save the settings.  
7.5.2  
WB Setup  
The WB (White Balance) feature automatically processes the  
displayed image to retain color balance over different color  
temperature ranges. In Manual mode, you can change the R or B  
gain value to adjust the colors displayed on the monitor.  
To set white balance settings:  
1. From the MAIN MENU, select CAMERA SETUP. The  
submenu CAMERA SETUP appears.  
2. Select W-Balance. The screen WB SETUP appears.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 43  
WB SETUP  
MODE  
R GAIN  
B GAIN  
SAVE  
BACK  
3. Select the option "Mode."  
4. Select the appropriate value:  
Auto Trace White balance (ATW): Aligns the white  
balance automatically. (2,300 to 11,000 K)  
Indoor: 3200 K Base Mode  
Outdoor: 5400 K Base Mode  
Push WB mode: The white balance is aligned during  
key input. (White balance push auto key)  
Manual WB mode: Red and Blue gain values can be set  
by user, 0 ~ 255  
Auto White Balance mode (AWB): Wide range auto  
white balance mode. In this mode, the white balance  
is performed at a faster operating speed than ATW.  
5. Select the option "R Gain" to set the red gain.  
6. Select the appropriate value.  
7. Select the option "B Gain."  
8. Select the appropriate value.  
9. Save the settings.  
7.5.3  
AE Setup  
Shutter speed controls the electronic shutter. Set the shutter  
speed to operate automatically (Auto) or manually (Numeric  
Value). The Automatic Gain Control (AGC Gain or AGC Max)  
adjusts the brightness of the pictures. The brightness increases  
as the numeric value is set higher. SSNR enhances the digital  
noise reduction properly. There are three settings: Low/Middle/  
High. When gain levels raise, SSNR will reduce the noise to  
display a clearer image. When Input luminance level is too dark,  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
44 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
the Digital Slow Shutter (DSS) function is set higher  
automatically.  
To set auto exposure settings:  
1. From the MAIN MENU, select CAMERA SETUP. The  
submenu CAMERA SETUP appears.  
2. Select EXPOSURE. The screen AE SETUP appears.  
AE SETUP  
MODE  
SHUT  
AGC GAIN  
AGC MAX  
DSS  
BRIGHT  
SAVE  
BACK  
3. Select the option "Mode" (Auto Exposure (AE) Mode).  
4. Select the appropriate values (listed in the top row of the  
table below):  
AE Mode  
Full Auto Manual  
SHUT FIX WDR  
Shutter  
X
O (1/1000) O (1/1000) X  
(1/1~1/100,000)  
AGC Gain (00~36dB)  
AGC Max  
X
O
O (06dB)  
X
X
X
O
O (High)  
(Off/Low/Mid/High/  
(default:  
Super)  
High)  
DSS (0x2~0x128Fld) O (Off)  
X
X
X
X
O
Bright (00~15)  
O (06)  
O (06)  
5. Save the settings.  
7.5.4  
D/N Setup  
The D/N (Day/Night) function improves the camera’s sensitivity  
at night or when the brightness level of the ambient  
environment is low. The Day & Night filter is automatically  
switched according to the luminance level. To set day/night:  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 45  
1. From the MAIN MENU, select CAMERA SETUP. The  
submenu CAMERA SETUP appears.  
2. Select DAY/NIGHT. The screen D/N SETUP appears.  
D/N SETUP  
DAY/NIGHT  
D&N DETECT  
D/N DTIME  
SAVE  
BACK  
3. Select the option "Day/Night."  
4. Select the appropriate value:  
Auto  
Day  
Night  
5. Select the option "D&N Detect."  
6. Select the appropriate value:  
Auto  
Sensor  
Video  
7. Select the option "D/N Dtime."  
8. Select the desired time to switch between day and night  
mode.  
9. Save the settings.  
7.5.5  
Advanced  
Brightness increases as the numeric value is set higher. The  
backlight compensation function provides compensation by  
increasing the brightness of the overall displayed image.  
Subjects being shot with dark details due to backlight ,will have  
the correct brightness levels. Sharpness enhances the picture  
detail by increasing the aperture gain of the camera and  
sharpening the edges in the picture. To set sharpness and  
backlight settings:  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
1. From the MAIN MENU, select CAMERA SETUP. The  
submenu CAMERA SETUP appears.  
2. Select ADVANCED. The screen ADVANCED SETUP  
appears.  
ADVANCED SETUP  
SHARPNESS  
BACKLIGHT  
SAVE  
BACK  
3. Select the option "Sharpness."  
4. Set the sharpness level.  
5. Select the option "Backlight."  
6. Select the appropriate value: ON or OFF.  
7. Save the settings.  
7.5.6  
WDR/DNR  
When both high-brightness subjects and low-brightness  
subjects need to be displayed at the same time, overexposure  
in the high-brightness areas or a loss of dark detail in the low-  
brightness areas may occur. The WDR (Wide Dynamic Range)  
function creates images free from over-exposure or loss of dark  
detail by combining two images from tripping the shutter for a  
long exposure time and for a short exposure time in one field.  
The DNR (Digital Noise Reduction) function creates ’noiseless’  
images, even in low light. In ’WDR on’ mode, unnatural color or  
image, and noise, may occur in a bright area. Under special  
illumination, it is better to avoid using the WDR function. To set  
WDR and DNR settings:  
1. From the MAIN MENU, select CAMERA SETUP. The  
submenu CAMERA SETUP appears.  
2. Select WDR/DNR. The screen WDR/DNR appears.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 47  
WDR/DNR  
WDR SETUP  
WDR LEVEL  
DNR SETUP  
DNR LEVEL  
SAVE  
BACK  
3. Select the option "WDR Setup."  
4. Select the value "On."  
5. Select the option "WDR Level."  
6. Set the appropriate level.  
7. Select the option "DNR Setup."  
8. Select the value "On."  
9. Select the option "DNR Level."  
10. Set the appropriate level.  
11. Save the settings.  
7.6  
Dome Motion Setup  
DOME MOTION SETUP  
GENERAL SETUP  
MOTION SETUP  
HOME ACTION  
CALIBRATION  
EXIT  
From this menu, you can set the general functions of the dome,  
motion functions of the pan/tilt/zoom motor, the home action,  
and calibration.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
48 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
7.6.1  
General Setup  
This menu controls general functions of the camera: power-up  
action, turbo speed, preset speed. To set these functions:  
1. From the MAIN MENU, select DOME MOTION. The  
submenu DOME MOTION appears.  
2. Select GENERAL SETUP. The screen GENERAL SETUP  
appears.  
GENERAL SETUP  
POWER-UP ACT.  
TURBO SPEED  
PRESET SPEED  
SAVE  
BACK  
3. Select the option "Power-Up Act." The power-up action  
sets the function (preset, tour, pattern, and scan) that the  
system should perform when the power is cycled or after  
an alarm action.  
4. Select the value "On" so that the system will resume its  
prior activity after an alarm or a power failure.  
5. Select the option "Turbo Speed." This defines the pan and  
tilt speed during manual operation of Pan/Tilt only.  
6. Select the appropriate value: ON or OFF.  
7. Select the option "Preset Speed." This sets the speed  
when moving to a predefined preset.  
8. Select the appropriate value:  
Fast  
Normal  
Slow  
9. Save the settings.  
7.6.2  
Motion Setup  
This menu controls camera settings such as proportional pan/  
tilt, auto flip, and over tilt. To set these functions:  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 49  
1. From the MAIN MENU, select DOME MOTION. The  
submenu DOME MOTION appears.  
2. Select MOTION SETUP. The screen MOTION SETUP  
appears.  
MOTION SETUP  
PROP PAN/TILT  
AUTO FLIP  
OVER TILT  
SAVE  
BACK  
3. Select the option "Prop. Pan/Tilt."  
4. Select the value "On" to allow proportional pan/tilt when  
Zoom is set to manual.  
5. Select the option "Auto Flip." This is a function that  
automatically reverses the image when the zoom module  
passes through the top of the tilt point (90 degrees).  
6. Select the value "On".  
7. Select the option "Over Tilt." This function restricts the  
vertical view angle to a specific operational range to  
mechanically restrict certain angles.  
8. Select the appropriate value:  
Mode 0  
Mode 1  
Mode 2  
Each Mode restricts the vertical minimum tilt to prevent  
horizontal block on the view from the camera’s cover.  
9. Save the settings.  
7.6.3  
Home Action  
The Home Action sets the function that the camera should  
perform after the joystick controller has been idle for  
predetermined amount of time. The Home Action can be set to  
a preset, a tour, or auto scan. The dwell time can be set from 1  
second to 60 seconds and from 1 minute to 60 minutes.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
50 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
NOTICE!  
In order to call an action (Preset, Pattern, Tour, or Scan), you  
must configure Preset, Pattern, Tour, or Scan first.  
1. From the MAIN MENU, select DOME MOTION. The  
submenu DOME MOTION appears.  
2. Select HOME ACTION. The screen HOME ACTION SETUP  
appears.  
HOME ACTION SETUP  
ACTION  
NUMBER  
TIME  
MODE  
SAVE  
BACK  
3. Select the option "Action."  
4. Select the appropriate value:  
Home  
Preset  
Scan  
Tour  
5. Select the option "Number."  
6. Set the number for the action. For example, if "Action" is  
"Preset" and "Number" is "001," this means Preset 1.  
7. Select the option "Time." This is the dwell time, the  
amount of time that the joystick controller can be idle  
before the camera returns to Home, a preset, a scan, or a  
tour.  
8. Set the desired dwell time (from 1 second to 60 seconds  
and from 1 minute to 60 minutes).  
9. Select the option "Mode."  
10. Select the appropriate value: Off (Manual) or On (Auto).  
11. Save the settings.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 51  
7.6.4  
Calibration  
Calibration is a function for automatically correcting an error on  
the angle of Pan/Tilt. Calibration can be set at Auto or Manual.  
In Auto mode, the camera is corrected automatically whenever  
there is an error on the angle of the camera. The motor of the  
Pan/Tilt will adjust its angle automatically. In Manual mode,  
select the option "Calibration" to execute the function.  
Error Message Display is a function for displaying an error  
message to let a user know when there is an error.  
1. From the MAIN MENU, select DOME MOTION. The  
submenu DOME MOTION appears.  
2. Select CALIBRATION. The screen CALIBRATION SETUP  
appears.  
CALIBRATION SETUP  
AUTO CAL  
ERROR MSG DISP  
CALIBRATION  
SAVE  
BACK  
3. Select the option "Auto Cal". This function is for automatic  
calibration.  
4. Select the appropriate value: AUTO or MANUAL.  
5. In Manual mode, select the option "Calibration" to execute  
the function using the joystick.  
6. Select the option "Yes" or press the [Near] button to  
continue.  
7. Select the option "Error Msg Disp" (Error Message  
Display).  
8. Select the appropriate option: ON or OFF.  
9. Save the settings.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
52 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
7.7  
Preset Setup  
The camera has a maximum of 210 programmable preset  
positions. Each of the user-defined presets includes Pan/Tilt/  
Zoom. To set up (program) a preset:  
1. From the MAIN MENU, select PRESET SETUP. The screen  
PRESET SETUP appears.  
PRESET SETUP  
NO.  
EDIT  
TITLE  
D TIME  
CLEAR  
SAVE  
BACK  
2. Select the option "NO.###" to select a preset number.  
3. Select the appropriate preset number.  
4. Select the option "Edit." A second screen PRESET SETUP  
appears.  
5. Using the joystick, move to a desired target (Pan/Tilt/  
Zoom).  
6. Save the settings.  
7. Return to the previous screen.  
8. Select the option "D Time" to set the dwell time for the  
preset.  
9. Set the desired dwell time (from 3 to 60 seconds).  
10. Save the settings.  
Note: Select the option "Clear" to delete the preset.  
NOTICE!  
You can also edit the Preset title. Select the option "Title," then  
edit the title following the steps in Section 7.2.1 Editing Titles,  
page 32.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 53  
7.8  
Pattern Setup  
A Pattern is used to display (or recall) a memorized, repeated  
and serial trace of pan, tilt, and zoom. The camera has a  
maximum of 8 Patterns in Pelco protocol mode, and 2 Patterns  
in Bosch protocol mode. Each of the user-defined scans  
includes Pan/Tilt/Zoom. To set up (program) a Pattern:  
1. From the MAIN MENU, select PATTERN SETUP. The  
screen PATTERN SETUP appears.  
PATTERN SETUP  
NO.  
EDIT  
TITLE  
TIME  
CLEAR  
SAVE  
BACK  
2. Select the option "NO.###" to select a pattern number.  
3. Select the appropriate pattern number.  
4. Select the option "Edit." A second screen PATTERN SETUP  
appears.  
5. Using the joystick, move to a desired target.  
6. Press the button [Near] to begin programming.  
7. Using the joystick, record the scene. Note that ’Time’  
means recorded time. The maximum amount of time  
available for recording is 60 seconds.  
8. Save the settings.  
Note: Select the option "Clear" to delete the pattern.  
NOTICE!  
You can also edit the Pattern title. Select the option "Title,"  
then edit the title following the steps in Section 7.2.1 Editing  
Titles, page 32.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
54 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
7.9  
Tour Setup  
The camera has a maximum of 8 Tours in Pelco protocol mode,  
and 2 Tours in Bosch protocol mode. Each tour can have 28  
configurable items. Each item can be a pre-defined preset,  
pattern, and scan in Tour 2-8. (Only Presets (28 maximum) can  
be inserted in Tour 1.) To set up (program) a tour:  
1. From the MAIN MENU, select TOUR SETUP. The screen  
TOUR SETUP appears.  
TOUR SETUP  
NO.###  
(-TOUR1: PRESET ONLY)  
SAVE  
BACK  
- CHANGE ID  
(- CHANGE ACT)  
(- CLEAR ID)  
2. Select a tour number.  
3. Select the first item in the list. From here you can:  
Press the button [Tele/Wide] to select a Preset, a  
Pattern, a Tour, and/or a Scan in each item.  
Press the button[Tele/Wide] to change the number of  
the action.  
Press the button [Near/Far] to change the mode of  
the action.  
Press the button [Near/Far] to clear (delete) the  
action in each item.  
4. Repeat steps 2 and 3 for additional tours.  
5. Save the settings.  
Note: Select the option "Clear" to delete the tour.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 55  
7.10  
Scan Setup  
An Auto scan is a PTZ function that moves the camera from one  
position to another position. The camera has a maximum of 8  
programmable scans. The speed of Auto Scan can be changed  
from 1 to 35 degree/sec. To set up (program) an auto scan:  
1. From the MAIN MENU, select SCAN SETUP. The screen  
SCAN SETUP appears.  
SCAN SETUP  
NO.  
EDIT  
SPEED  
DTIME  
DIRECTION  
MODE  
CLEAR  
SAVE  
BACK  
2. Select the option "NO.###" to select a scan number.  
3. Select the appropriate scan number.  
4. Select the option "Edit."  
5. Select the value "Edit Start Point." The screen Start  
Position Setup appears.  
6. Using the joystick, move to a desired target (Pan/Tilt/  
Zoom) for the starting point of the scan.  
7. Save the settings. The screen Stop Position Setup  
appears.  
8. Using the joystick, move to a desired target (Pan/Tilt/  
Zoom) for the stopping point of the scan.  
9. Save the settings.  
10. Return to the previous screen.  
11. Select the option "Speed."  
12. Select the desired speed (from 1° to 35°/second).  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
56 en | On-Screen Display (OSD) Menu  
VEZ-400 Mini PTZ Dome  
13. Select the option "DTime" to set the dwell time for the  
scan.  
14. Set the desired time (from 3 minute to 60 seconds).  
15. Select the option "Direction."  
16. Select the appropriate value for the direction of the scan.  
17. Select the option "Mode."  
18. Select the appropriate value for the mode. In Auto Scan  
there are two modes:  
Endless mode: When the Start Position is the same as  
the Stop Position, the dome moves around.  
Coming/Going mode: When the Start Position is  
different from the Stop Position, the dome moves  
repeatedly from one position to another.  
19. Save the settings.  
Note: Select the option "Clear" to delete the scan.  
In order to call an action (Preset, Pattern, Tour, or Scan),  
you must save Preset, Pattern, Tour, or Scan first.  
You can also edit the Scan title. Select the option "Title,"  
then edit the title following the steps in  
Section 7.2.1 Editing Titles, page 32.  
7.11  
Alarm Setup  
This menu controls alarm inputs and outputs. To set alarms:  
1. From the MAIN MENU, select ALARM SETUP. The screen  
ALARM SETUP appears.  
2. Select the option "NO.###" to select a preset number.  
ALARM SETUP  
NO.  
IN  
OUT  
PRIORITY  
ACTION  
NUMBER  
ATIME  
SAVE  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
On-Screen Display (OSD) Menu | en 57  
ALARM SETUP  
BACK  
- SET/CLEAR  
3. Select the appropriate alarm number.  
4. Select the option "In" to select the alarm input type.  
5. Select the appropriate value: N.O. (Normally Open) or N.C.  
(Normally Closed).  
6. Select the option "Out" to select the alarm output.  
7. Select the appropriate value: ON or OFF.  
8. Select the option "Priority."  
9. Select the appropriate priority from 1-4.  
10. Select the option "Action."  
11. Select the appropriate action: Off, Preset, Pattern, Scan,  
or Tour.  
12. Select the option "Number."  
13. Select the number of the action (Preset, Pattern, Scan, or  
Tour).  
14. Select the option "ATime" to set the alarm time for the  
action.  
15. Set the desired dwell time:  
Time Out (3-60seconds). This is activated during a  
selected dwell time when an alarm is triggered.  
Momentary (On): When an alarm is triggered, the  
camera will maintain alarm activation continuously,  
until it is stopped manually (96+preset in Pelco  
protocol; [Off]+[65]+[Enter] in Bosch protocol).  
16. Save the settings.  
Note: Select the option "Clear" to delete the alarm.  
NOTICE!  
In order to call an action (Preset, Pattern, Tour, or Scan), you  
must save Preset, Pattern, Tour, or Scan first.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
58 en | Troubleshooting  
VEZ-400 Mini PTZ Dome  
8
Troubleshooting  
If problems occur, check the installation of the camera with the  
instructions in this manual. Refer to this guide for further  
information.  
Problem  
Solution  
No video on screen.  
- Verify that the power is connected  
to all components in the system.  
- Verify that the power switch is ON.  
- Verify the status of cables or the  
connection of cables.  
Poor video quality.  
- Check the power supply voltage  
(normal 24 VAC) directly at the  
camera.  
- Check the camera settings.  
- Check the video quality directly at  
the camera with a service monitor.  
- Check the quality and length of  
video cables, and possible EMC  
interference.  
- Check the quality of connectors  
and potential moisture/corrosion.  
- If the lens or the dome window is  
dirty, clean it with a clean cloth.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Troubleshooting | en 59  
Problem  
Solution  
Camera is not working  
- Power-cycle the camera and power  
supply, or reset the camera using  
the configuration menu [Main >  
System > Reboot].  
properly (including  
wrong position of  
camera).  
- Check the connection of the power  
cable and the status of the camera.  
- Initialize the camera [Main >  
System > Initialize].  
- Check the power rating of the  
power supply.  
- Measure the voltage at the camera  
(since there could be a drop in  
voltage due cable length). The  
power consumption increases when  
the camera is moving (especially at  
high speed) and when the heater is  
on. The voltage at the camera should  
always be 24VAC (+/- 10%).  
The communication  
- Check that the RS-485 cable is  
between controller and connected correctly.  
camera (via RS-485  
cable) is not working  
properly.  
- Check the ID/Protocol/Baud rate/  
Termination setting.  
The surface of the dome - Check the voltage level of the dome  
case is hot.  
camera and the status of the  
camera.  
- Check that the camera is  
connected to the proper power.  
The image on the screen - Check to see if the camera faces  
flickers.  
directly into the sun or a fluorescent  
lamp. If so, reposition the dome.  
- Check for flickers on the screen.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
60 en | Technical Specifications  
VEZ-400 Mini PTZ Dome  
9
Technical Specifications  
Camera Module  
Imager  
Effective Pixels  
1/4" Double Scan, Super HAD CCD  
NTSC: 976(H)*494(V),  
PAL: 976(H)*582(V)  
600 TVL  
26X Effective Optical Zoom/10X  
Resolution  
Zoom ratio  
Digital Zoom (Auto Focus)  
fW=3.49 0.17mm  
Lens  
fT=104.02 5.20mm  
(30X +/- 10% Optical Zoom)  
View Angle (Approximate) 69.5° to 2.46°  
Day/Night  
Mechanical Day/Night filter  
Minimum Illumination  
0.2 Lux/ F1.65, 0.001 Lux/DSS,  
0.1 Lux/ICR  
Signal-to-Noise Ratio (SNR) >50 dB  
Wide Dynamic Range  
On/Off  
(WDR)  
Dynamic Noise Reduction 3 DNR  
(DNR)  
Privacy Masking  
Maximum Preset Speed  
Flip  
15 zones maximum  
360°/sec  
Rotate 180° at bottom of tilt  
2/8 Auto Scan modes including  
Auto Scan  
vector scan  
Preset Position  
99/210 Positions with camera  
status  
Tour  
Pattern  
2/8 Tours (Preset, Pattern, Scan)  
2/8 Patterns  
On-screen Display (OSD)  
Display camera ID, Title, Mode,  
and Angle on-screen(Multi-  
Language)  
Multi-language OSD  
English, Chinese, Dutch, German,  
French, Italian, Russian, Spanish  
Electrical  
Power Supply  
24 VAC ( 10%) Normal, Built-in  
Power Line Surge  
Power Requirements  
Adaptor 24VAC, 1A (2.5A with  
heater)  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Technical Specifications | en 61  
Camera Module  
Power Consumption  
24 VAC, 850mA / 20W (without  
heater)24 VAC, 2A / 45W (with  
heater)  
Alarm Input  
Alarm Output  
Control  
4 Normal Dry Contact (Selectable  
NC/NO)  
1 Normal Relays 5VDC/40mA Max  
(Selectable NC/NO)  
RS-485 baud rate: 2400~38.4Kbps  
(default: 9600bps)  
Access Time  
0.75 second maximum preset  
recall time  
Physical 99  
Camera Address / ID  
Mechanical  
Weight  
1.5 kg  
Dimension  
Ø154 x 138 mm (H) (Bubble Dome  
Ø110)  
Pan Angle  
360° Continuous rotation  
Environment  
Operating Temperature  
-10 °C to +50 °C (14 °F to +122 °F)  
(heater off)  
-40 °C to +10 °C (-40 °F to 50 °F)  
(heater on)  
Heater (Built-in)  
On/Off: 0 °C to 10 °C  
Operating Humidity  
Storage Temperature  
~80% relative humidity (RH)  
-20 °C to +60 °C (-4 °F to +140 °F)  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
62 en | Dimensions  
VEZ-400 Mini PTZ Dome  
10  
Dimensions  
Ø112  
(4.41)  
Ø151.3  
(5.96)  
mm  
Ø154  
(6.06)  
(in.)  
Figure 10.1 Dimensions - Camera  
4-Ø4.8  
(0.19)  
mm  
(in.)  
85.6  
(3.37)  
Figure 10.2 Dimensions - Mounting Holes  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Bosch Protocol | en 63  
11  
Bosch Protocol  
The following table lists camera functions in Bosch protocol.  
Preset  
Key  
Preset  
Example  
Number  
Function  
Activate/ Command  
Example  
Deactivate  
Auto Scan 1  
Auto Scan 2  
Pre-Position Tour  
Group Tour  
Backlight  
On/Off  
On/Off  
On/Off  
On/Off  
On/Off  
Scan 1  
Scan 2  
Tour 1  
Tour 2  
ON+1+Enter  
ON+2+Enter  
ON+8+Enter  
ON+9+Enter  
ON+20+Enter  
Backlight Comp.  
Compensation  
Enters White Balance On/Off  
WB Setup  
ON+35+Enter  
menu  
Restores Camera  
On  
Camera Default Restored ON+40+Enter  
Settings  
Enters Main Setup  
On  
Main Menu  
Pattern 1  
ON+46+Enter  
ON+50+Enter  
Menu  
Playback A  
On/Off  
(Continuous)  
Playback A (Single)  
Playback B  
On/Off  
On/Off  
Pattern 1  
Pattern 2  
ON+51+Enter  
ON+52+Enter  
(Continuous)  
Playback B (Single)  
Enters Alarm Menu  
Acknowledge Alarms Off  
On/Off  
On  
Pattern 2  
Alarm Menu  
Alarm Action stopped  
ON+53+Enter  
ON+64+Enter  
Off+65+Enter  
and Deactivate Alarms  
Displays SW version On  
*SW Ver. Displayed  
*Digital Zoom  
Privacy Masking  
Pattern 1  
ON+66+Enter  
ON+80+Enter  
ON+87+Enter  
ON+100+Enter  
ON+101+Enter  
Set+99+Enter  
no.  
Changes to Digital  
On/Off  
Zoom mode  
Enters Privacy  
On/Off  
On/Off  
On/Off  
Set  
Masking menu  
Record A: Enters  
Pattern Setup menu  
Record B: Enters  
Pattern 2  
Pattern setup menu  
Pre-Position  
Preset 1-99  
Programming  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
64 en | Bosch Protocol  
Preset  
VEZ-400 Mini PTZ Dome  
Key  
Preset  
Example  
Number  
Pre-Position Recall  
Set-recalibrate Home Set  
Shot  
Preset 1-99  
Run Calibration  
Shot+99+Enter  
Set+110+Enter  
Position  
Restores all settings  
Factory Reset  
Set+899+Enter  
* SW Version Number displays 5seconds.  
*OSD message “D.ZOOM” in D.Z range displays 2 seconds.  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VEZ-400 Mini PTZ Dome  
Pelco Protocol | en 65  
12  
Pelco Protocol  
The following table lists camera functions in Pelco protocol.  
Preset  
Key  
Preset Operation Example  
Number  
Preset  
Preset  
1-59,  
No.+Preset 1+Preset  
101-250  
1-59,  
Preset shortcut * Preset  
saving  
*
*
101-250  
33  
34  
60  
61-68  
Run PAN  
Preset  
No.+Preset 33+Preset  
No.+Preset 34+Preset  
No.+Preset 60+Preset  
No.+Preset 61+Preset  
Run PAN ZERO Preset  
Scan Setup  
Scan  
Preset  
Preset/Scan  
1+Scan  
No.+Preset 70+Preset  
No.+Preset 71+Preset  
Tour Setup  
Tour  
Preset  
Preset/Tour  
70  
71-78  
1+Tour  
Pattern Setup Preset  
80  
No.+Preset 80+Preset  
No.+Preset 81+Preset  
Pattern  
Preset/Pattern 81-88  
1+Pattern  
No.+Preset 90+Preset  
No.+Preset 91+Preset  
No.+Preset 92+Preset  
No.+Preset 94+Preset  
No.+Preset 95+Preset  
No.+Preset 96+Preset  
No.+Preset 97+Preset  
ENT Key  
Preset  
Preset  
Preset  
Preset  
Preset/**Menu 95  
Preset  
Preset  
90  
91  
92  
94  
Run HOME  
CLR Key  
ENT2 Key  
MENU Key  
ESC Key  
D.Zoom  
96  
97  
(Toggle)  
NOTICE!  
#
- To save position of the dome, press the desired preset number  
and hold the [PRESET] key for 2 seconds.- To go to the MAIN  
MENU, press and hold the [MENU] key for 2 seconds.  
Bosch Security Systems, Inc.  
User Manual  
F.01U.252.635 | 2.0 | 2011.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
66 en | Pelco Protocol  
VEZ-400 Mini PTZ Dome  
F.01U.252.635 | 2.0 | 2011.09  
User Manual  
Bosch Security Systems, Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bosch Security Systems, Inc.  
850 Greenfield Road  
Lancaster, PA 17601  
U.S.A.  
© Bosch Security Systems, Inc., 2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker PDAs Smartphones CM090 CM090 2 User Manual
Boston Acoustics Car Speaker Neo Type M SE User Manual
Brookstone Work Light 740157 User Manual
Brother Sewing Machine 885 V95 User Manual
Cables to Go TV Converter Box 29548 User Manual
Casio Digital Camera EX Z850 User Manual
Casio Personal Computer ACS V6000 User Manual
Casio Watch 1940 1 User Manual
Cecilware Hot Beverage Maker Multi Flavor Dispensers User Manual
Cisco Systems IP Phone OL 20949 01 User Manual