Plena Two-zone Call Station | Installation and User Instructions | Table of contents
en | 3
Important safeguards...................................................................................................................................................2
Table of contents...........................................................................................................................................................3
1. Introduction ....................................................................................................................................................................5
1.1 Purpose .....................................................................................................................................................................................5
1.2 Digital document .....................................................................................................................................................................5
1.3 Intended audience ..................................................................................................................................................................5
1.4 Related documentation ..........................................................................................................................................................5
1.5 Alerts ..........................................................................................................................................................................................5
1.6 Icons ...........................................................................................................................................................................................5
1.6.1 Note icons ...........................................................................................................................................................................5
1.6.2 Caution, Warning, and Danger icons ...........................................................................................................................5
1.7 Conversion tables ...................................................................................................................................................................6
2. Description .....................................................................................................................................................................7
2.1 The Plena product range .......................................................................................................................................................7
2.2 Contents of box .......................................................................................................................................................................7
2.3 The Plena Two-zone Call Station ........................................................................................................................................7
2.3.1 Balanced line level output ...............................................................................................................................................7
2.3.2 Loop-through RJ-45 sockets ..........................................................................................................................................7
2.3.3 DIP switches and status LEDs .......................................................................................................................................7
2.3.4 PTT button ...........................................................................................................................................................................7
2.4 Controls, connectors and indicators ..................................................................................................................................8
2.4.1 Top side ...............................................................................................................................................................................8
2.4.2 Bottom side .........................................................................................................................................................................8
3. Installation ......................................................................................................................................................................9
3.1 Unpack unit ...............................................................................................................................................................................9
3.2 Connect unit to PLE-series two-zone mixer (amplifier) ...................................................................................................9
3.3 Make configuration settings ..................................................................................................................................................9
4. Connections and settings ........................................................................................................................................ 11
4.1 Connecting multiple call stations ..................................................................................................................................... 11
4.2 Configuration settings ......................................................................................................................................................... 11
4.2.1 Chime settings ................................................................................................................................................................ 11
4.2.2 Momentary or latching speaking setting ................................................................................................................... 11
4.2.3 Speech filter setting ....................................................................................................................................................... 11
4.2.4 Microphone gain settings ............................................................................................................................................. 12
5. Operation ..................................................................................................................................................................... 13
5.1 Make calls (momentary speaking function) .................................................................................................................... 13
5.2 Make calls (latching speaking function) .......................................................................................................................... 13
5.3 Adjust the call station output volume ............................................................................................................................... 13
6. Technical data ............................................................................................................................................................. 15
6.1 Electrical ................................................................................................................................................................................. 15
6.2 Performance .......................................................................................................................................................................... 15
6.3 Interconnection ..................................................................................................................................................................... 15
6.4 Mechanical ............................................................................................................................................................................. 15
6.5 Environmental conditions ................................................................................................................................................... 15
6.6 Certifications and Approvals ............................................................................................................................................. 15
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Table of contents
en | 4
Intentionally left blank
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Introduction
en | 5
1
Introduction
1.6
Icons
1.6.1 Note icons
1.1
Purpose
The icons used in combination with Notes provide extra
information about the Note. See the following
examples:
The purpose of these Installation and User Instructions
is to provide information that is required to install,
configure and operate a Plena Two-zone Call Station.
1.2
Digital document
Note
General icon for notes.
These Installation and User Instructions are also
available as a digital document in the Adobe Portable
Document Format (PDF). All references to pages,
figures, tables, etc. in this digital document contain
hyperlinks to the referenced location.
Note
Consult the indicated source of information.
1.3
Intended audience
These Installation and User Instructions are intended
for installers and users of a Plena Two-zone Call Station.
1.6.2 Caution, Warning, and Danger
icons
The icons used in combination with Caution, Warnings,
and Dangers indicate the type of hazard present. See the
following examples:
1.4
Related documentation
Safety Instructions (9922 141 ****).
1.5
Alerts
Four types of alerts are used in this manual. The alert
type is closely related to the effect that may be caused if
it is not observed. These alerts - from least severe effect
to most severe effect - are:
Caution, Warning, Danger
General icon for Cautions, Warnings and
Dangers.
•
Note
Alert containing additional information. Usually, not
observing a note alert does not result in damage to
the equipment or personal injuries.
Caution
The equipment can be damaged if the alert is not
observed.
Caution, Warning, Danger
Icon for risk of electric shock.
•
•
Warning
Caution, Warning, Danger
Icon for risk of electrostatic discharge.
Persons can be (severely) injured, or the equipment
can be seriously damaged, if the alert is not
observed.
•
Danger
Not observing the alert can result in death.
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Introduction
en | 6
1.7
Conversion tables
In this manual, SI units are used to express lengths,
masses, temperatures etc. These can be converted to
non-metric units using the following information.
table 1.1: Conversion of units of length
1 in =
1 in =
1 ft =
1 mi =
25.4 mm
2.54 cm
0.3048 m
1.609 km
1 mm =
1 cm =
1 m =
0.03937 in
0.3937 in
3.281 ft
1 km =
0.622 mi
table 1.2: Conversion of units of mass
1 lb = 0.4536 kg 1 kg =
2,2046 lb
0.0145 psi
table 1.3: Conversion of units of pressure
1 psi = 68.95 hPa 1 hPa =
Note
1 hPa = 1 mbar.
table 1.4: Conversion of units of temperature
5
9
9
5
--
°C = ⋅ (°F – 32)
--
°F = ⋅ °C + 32
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Description
en | 7
2
Description
The Plena Two-zone Call Station features:
•
a selectable microphone gain level, a selectable
a balanced line level output. See section 2.3.1.
DIP switches and status LEDs. See section 2.3.3.
a push-to-talk (PTT) button. See section 2.3.4.
2.1
The Plena product range
•
•
•
•
The Plena Two-zone Call Station is part of the Plena
product range. Plena provides public address solutions
for places where people gather to work, worship, trade,
or relax. It is a family of system elements that are
combined to create public address systems tailored for
virtually any application
For a detailed description of all controls, connections
and indicators, see section 2.4.
The Plena product range includes:
2.3.1 Balanced line level output
The Plena Two-zone Call Station has a balanced line
level output, giving it a maximum range of 200 m from
the controller when using Cat-5 Ethernet cables.
•
•
•
•
•
•
•
•
•
•
•
•
•
mixers
mixer amplifiers
preamplifiers
power amplifiers
a music source unit
a digital message manager
a feedback suppressor
call stations
an All-in-One system
a voice alarm system
a timer
2.3.2 Loop-through RJ-45 sockets
With the loop-through RJ-45 sockets, it is possible to
daisy chain up to six call stations. The priority is
automatic; the call station nearest to the mixer has
priority and can override the call station further away
from the mixer.
a charger
a loop amplifier
2.3.3 DIP switches and status LEDs
With the DIP switches at the base of the call station you
can select different microphone gain levels, seven
different chimes (any .wav file), define the speech filter
and the momentary or latching speaking functions.
Two LEDs on top of the call station show which zones
have been selected. One additional LED gives visible
feedback on the active state of the microphone and the
system:
The various elements are designed to complement each
other thanks to matched acoustical, electrical and
mechanical specifications.
Contents of box
The packaging box contains the following:
•
•
PLE-2CS Plena Two-zone Call Station
Cable terminated with a lockable Cat-5 connector
•
green flashing: microphone is standby (chime is
sounding)
•
•
green continuous: microphone is active
off: a call is being made by a higher priority call
station
2.3
The Plena Two-zone Call
Station
The Plena Two-zone Call Station is a modern, high-
quality call station with a stable metal base design, a
flexible microphone stem and a unidirectional
condenser microphone. It can make calls to selected
zones (zone one or two) in a public address system built
with the PLE-series two-zone mixer and mixer
amplifiers.
2.3.4 PTT button
To the PTT button, a pre- and post chime can be
assigned that is played at the start or at the end of the
call. To this end, the call station is equipped with seven
built-in chimes.
In addition to tabletop use, the Plena design allows neat
flush-mounting in desktops.
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Description
en | 8
2.4
Controls, connectors and
indicators
2.4.2 Bottom side
See figure 2.2 for an overview of the controls and
indicators at the bottom of the call station:
2.4.1 Top side
1 Configuration settings - A set of DIP switches to
configure the call station (by setting the microphone
gain level, the chime and the speech filter). See
section 4.2.
2 System sockets - Two redundant RJ-45 sockets to
connect the call station to the PLE-series two-zone
mixer or mixer amplifiers using Cat-5 Ethernet
cables. When the system requires more than 2 call
stations, the system sockets can be used to make
loop-throughs. See section 4.1.
See figure 2.1 for an overview of the controls and
indicators on the top side of the call station:
1 Zone selection buttons - Two buttons to select
the zones to which the business call is distributed.
Each button has a green LED, which indicates the
zone to which the business call is distributed.
2 Push-to-talk (PTT) button - A push-to-talk
3 Status indicator - A LEDs that indicates the status
of the call station. See section 2.3.3.
control (potentiometer) to set the output volume of
the call station. See chapter 5.3.
Plena
2
1
3
3
2
1
figure 2.1: Top view
figure 2.2: Bottom view
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Installation
en | 9
3
Installation
3.1
Unpack unit
1 Remove the unit from the box, and discard the
packaging material according to local regulations.
2 Use your fingernails to carefully peel off the
protective plastic film. Do not use sharp or pointed
objects.
3.2
Connect unit to PLE-series
two-zone mixer (amplifier)
1 Connect the Plena Two-zone Call Station to the
PLE-series two-zone mixer or mixer amplifier using
a Cat-5 Ethernet cable (see figure 3.1). Either one of
the RJ-45 sockets can be used.
n a
e
l
P
a
n
l e
P
figure 3.1: Connecting the call station to the mixer or
the mixer amplifier
3.3
Make configuration settings
1 Make the configuration settings (see section 4.2).
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Installation
en | 10
Intentionally left blank
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Connections
en | 11
4
Connections and settings 4.2 Configuration settings
Use the DIP switches at the bottom of the call station to
set the chime, the momentary or latching speaking
function, the speech filter and the microphone gain. See
figure 4.2.
4.1
Connecting multiple call
stations
When the configuration requires more than one call
station, use the loop-through RJ-45 sockets on the call
stations to make loop-throughs.
4.2.1 Chime settings
See figure 4.2. DIP switches number 1, 2 and 3 are used
for setting the chime.
1 = ON-position, 0 = OFF-position.
Note
In such a daisy chain configuration the priority
table 4.1: Chime settings
is automatic; the call station nearest to the mixer
has priority and can override the call station
number 2 has priority over call station
number 3, etc. See figure 4.1.
DIP switch setting
(1-2-3)
0-0-0
0-0-1
0-1-0
Description
no chime
1-tone chime
2-tone chime
0-1-1
1-0-1
1-0-0
1-1-0
2-tone chime reversed
3-tone chime A
3-tone chime reversed B
4-tone chime A
4-tone chime C
P l e n a
1-1-1
setting
a
P l e n
See figure 4.2. DIP switch number 4 is used for setting
the momentary or latching speaking function.
1 = latching, 0 = momentary.
P l e n a
4.2.3 Speech filter setting
a
l e n
P
See figure 4.2. DIP switch number 5 is used for setting
the speech filter ON (1) of OFF (0).
n a
e
l
P
a
l e n
P
figure 4.1: Connecting multiple call stations
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Connections
en | 12
4.2.4 Microphone gain settings
See figure 4.2. DIP switches number 6 and 7 are used
for setting the microphone gain.
1 = ON-position, 0 = OFF-position.
table 4.2: Microphone gain settings
DIP switch setting
Description
(6-7)
0-0
1-0
0-1
1-1
-15 dB
0 dB
+6 dB
+6 dB
DIP
ON(1)
OFF(0)
1 2 3 4 5 6 7 8(spare)
figure 4.2: DIP switches
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Operation
en | 13
5
Operation
5.1
Make calls (momentary
speaking function)
1 Press the push-to-talk button and keep the button
depressed during the business call.
2 Make the business call.
3 Release the push-to-talk button after the business
call.
5.2
Make calls (latching speaking
function)
1 Shortly press the push-to-talk button to start the
business call.
figure 5.1: Adjust the output volume
2 Make the business call.
3 Shortly press the push-to-talk button to stop the
business call.
5.3
Adjust the call station output
volume
1 Use a screw driver to adjust the output volume of the
call station. Turn clockwise to increase the output
volume or turn counterclockwise to decrease the
output volume. See figure 5.1.
Caution
Be careful not to damage the printed circuit
board located directly underneath the orifice.
Use a small screw driver, preferably a plastic
one.
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Operation
en | 14
Intentionally left blank
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Technical data
en | 15
6
Technical data
6.4
Mechanical
Base dimensions (H x W x D), without
microphone:
6.1
Voltage range:
Electrical
40 x 100 x 235 mm (1.57 x 3.97 x 9.25 in)
Stem length (with microphone):
390 mm (15.35 in)
24 V(DC), supplied by PLE-series mixer or mixer
amplifier.
Current consumption:
< 30 mA
Cat-5 extension cable length:
5 m (16.4 ft)
Weight:
Approx. 1 kg (2.2 lb)
Mounting:
6.2
Performance
Nominal sensitivity:
Standalone
85 dB SPL (gain preset 0 dB)
Nominal output level:
700 mV
Maximum input sound level:
110 dB SPL
Color:
Charcoal with silver
6.5
Environmental conditions
Operating temperature range:
Gain preset:
-15 / 0 / +6 dB
Limiter threshold:
2 V
-10 °C to +55 °C (+14 °F to +131 °F)
Storage temperature range:
-40 °C to +70 °C (-40 °F to +158 °F)
Relative humidity:
Compression ratio limiter:
1:20
Distortion:
< 95%
6.6
Certifications and Approvals
< 0.6% (maximum input)
Equivalent input noise level:
25 dB SPL(A)
Safety:
According to EN 60065
EMC immunity:
Frequency response:
100 Hz - 16 kHz
According to EN 55103-2
EMC emission:
Speech filter:
According to EN 55103-1
- 3 dB @ 315 Hz, high-pass, 6 dB/oct
Output impedance:
200 Ω
6.3
Interconnection
Type:
2x redundant RJ-45 sockets for daisy chaining
multiple call stations.
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Plena Two-zone Call Station | Installation and User Instructions | Technical data
en | 16
Intentionally left blank
Bosch Security Systems | 2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Data subject to change without notice
2008-01 | PLE-2CS en
Download from Www.Somanuals.com. All Manuals Search And Download.
|