Bosch Appliances Car Amplifier LBB 1903 10 User Manual

Plena Mixer Amplifier  
Installation and Operating Manual  
LBB 1903/10, LBB 1906/10,  
LBB 1912/10, LBB 1914/10  
en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Plena Mixer Amplifier | Installation and Operating Manual | Important safeguards  
en | 3  
Important safeguards  
1
2
Read instructions - All the safety instructions for use  
should be read before the system is operated.  
Retain instructions - The safety instructions and  
instructions for use should be retained for future  
reference.  
Heed warnings - All warnings on the unit and in the  
operating instructions should be adhered to.  
Follow instructions - All operating instructions and  
instructions for use should be followed.  
Cleaning - Unplug system units from the mains outlet  
before cleaning. Do not use liquid cleaners or aerosol  
cleaners. Use a damp cloth for cleaning.  
Attachments - Do not use attachments not  
recommended by the product manufacturer as they may  
cause hazards.  
Water and Moisture - Do not use this unit near water, for  
example near a bathtub, washbowl, kitchen sink, or  
laundry basket, in a wet basement, near a swimming  
pool, in an unprotected outdoor installation or any area  
which is classified as a wet location.  
Accessories - Do not place this unit on an unstable stand,  
tripod, bracket or mount. This unit may fall, causing  
serious injury to a person and serious damage to the  
unit. Use only a stand, tripod, bracket or mount  
recommended by the manufacturer, or sold with the  
product. Any mounting of the unit should follow the  
manufacturer's instructions, and should use a mounting  
accessory recommended by the manufacturer. An  
appliance and cart combination should be moved with  
care. Quick stops, excessive force, and uneven surfaces  
may cause the appliance and cart combination to  
overturn.  
Ventilation - Openings in the enclosure, if any, are  
provided for ventilation and to ensure reliable operation  
of the unit and to protect it from overheating. These  
openings must not be blocked or covered. The unit  
should not be placed in a built-in installation unless  
proper ventilation is provided or the manufacturer's  
instructions have been adhered to.  
12 Power-Cord Protection - Power supply cords should be  
routed so that they are not likely to be walked on or  
pinched by items placed upon or against them, paying  
particular attention to cords and plugs, convenience  
receptacles, and the point where they exit from the  
appliance.  
3
4
5
13 Overloading - Do not overload outlets and extension  
cords as this can result in a risk of fire or electrical shock.  
14 Object and Liquid Entry - Never push objects of any  
kind into this unit through openings as they may touch  
dangerous voltage points or short-out parts that could  
result in a fire or electric shock. Never spill liquid of any  
kind on the unit.  
15 Servicing - Do not attempt to service this unit yourself as  
opening or removing covers may expose to dangerous  
voltage or other hazards. Refer all servicing to qualified  
service personnel.  
6
7
16 Damage Requiring Service - Unplug the unit from the  
outlet and refer servicing to qualified service personnel  
under the following conditions:  
8
When the power-supply cord or plug is damaged.  
If liquid has been spilled, or objects have fallen into  
the unit.  
If the unit has been exposed to rain or water.  
If the unit does not operate normally by following  
the instructions for use. Adjust only those controls  
that are covered by the instructions for use, as an  
improper adjustment of other controls may result in  
damage and will often require extensive work by a  
qualified technician to restore the units to their  
normal operation.  
If the unit has been dropped or the unit has been  
damaged.  
When the unit exhibits a distinct change in  
performance; this indicates a need for service.  
9
17 Replacement Parts - When replacement parts are  
required be sure the service technician has used  
replacement parts specified by the manufacturer or parts  
which have the same characteristics as the original part.  
Unauthorised substitutions may result in fire, electric  
shock or other hazards.  
18 Safety Check - Upon completion of any service or  
repairs to the units, ask the service technician to perform  
safety checks to determine that the unit is in proper  
operating condition.  
19 Lightning - For added protection of the units during a  
lightning storm, or when it is left unattended and unused  
for long periods of time, unplug it from the wall outlet  
and disconnect the cable system. This will prevent  
damage to the unit due to lightning and power-line  
surges.  
10 Power sources - Units should be operated only from the  
type of power source indicated on the marking label. If  
you are not sure of the type of power supply you plan to  
use, consult your appliance dealer or local power  
company. For units intended to operate from battery  
power, or other sources, refer to the "Installation and  
User Instructions".  
11 Grounding or polarisation - This unit may be equipped  
with a polarised alternating current line plug (a plug  
having one blade wider than the other). This plug will fit  
into the power outlet only one way. This is a safety  
feature. If you are unable to insert the plug fully into the  
outlet, try reversing the plug. If the plug still fails to fit,  
contact your electrician to replace your obsolete outlet.  
Do not defeat the safety purpose of the polarised plug.  
Alternatively, this unit may be equipped with a 3-wire  
grounding type plug having a third (grounding) pin.  
This plug will only fit into a grounding-type power  
outlet. This is a safety feature. If you are unable to insert  
the plug into the outlet, contact your electrician to  
replace your obsolete outlet. Do not defeat the safety  
purpose of the grounding-type lug.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Plena Mixer Amplifier | Installation and Operating Manual | About this manual  
en | 4  
About this manual  
This manual provides all the information required to install and operate the unit.  
Conventions  
Warning  
Follow these instructions to prevent personal injury.  
Caution  
Follow these instructions to prevent damage to the equipment.  
Note  
Read these instructions for tips and other useful information.  
Safety precautions  
Warning  
Do not open the unit when it is connected to the mains. The unit contains non-insulated parts, which can  
cause electric shock.  
Caution  
There are no user-serviceable parts inside the unit. Service must be done by qualified personnel.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Plena Mixer Amplifier | Installation and Operating Manual | Table of contents  
en | 5  
Table of contents  
6.6  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Plena Mixer Amplifier | Installation and Operating Manual | Table of Contents  
en | 6  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Plena Mixer Amplifier | Installation and Operating Manual | About the mixer amplifier  
en | 7  
1 About the mixer amplifier  
JP406  
JP401  
100V  
100V  
Phantom  
Power  
0
INS INS  
Out In  
70V  
70V  
0
Click  
suppression  
70V  
JP802  
100V  
JP402  
8 Ohm  
8 Ohm  
0
0
JP403  
LINE/MIC  
Call Only  
0
0
0
Mix Only  
0
JP405  
LINE/MIC  
24V  
+
24V  
Call Active  
-
201  
115V,230V  
Call Only  
0
0
0
0
0
Zone 1  
Call/Mix  
0
JP901  
100V  
Z1 Front  
100V  
70V  
JP902  
100/70  
70V  
8 Ohm  
8 Ohm  
0
Call/Mix  
0
0
0
Zone 2  
Call/Mix  
0
0
0
Z2 Front  
0
Mix Only  
0
24V  
+
Call Active  
24V  
-
Only for LBB1914/10  
Figure 1.1  
The Plena Mixer Amplifier is a mono amplifier for mixing up to 4 microphone signals and (background) music  
signals. You can adjust the volume of each input separately in order to obtain the correct mix and control the mixed  
output via the master volume and tone controls. Microphone input 1 can have priority with an optional chime  
signal, muting other sources. The power amplifier has a direct output for mixed signals and priority announcements,  
but additionally a priority controlled output relay routes the output to loudspeaker zones that should receive only  
priority announcements or no priority announcements at all.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Plena Mixer Amplifier | Installation and Operating Manual | About the mixer amplifier  
en | 8  
1.1 Controls and connections (front)  
2
3
4
8
9
Only for LBB1914/10  
Plena Mixer Amplifier  
1
3
2
4
Select  
CD  
0 dB  
-6 dB  
AUX  
Master  
Zone 1  
Zone 2  
-20 dB  
Line  
Power  
1
5
6
7
10  
11  
12  
13  
Figure 1.2  
1 Power button  
8 Music source selector (CD, tape, AUX)  
9 Master tone control (treble)  
10 Master tone control (bass)  
11 Master volume control (all inputs except emergency)  
12 Zone 1 selection button (LBB1914/10 only)  
13 Zone 2 selection button (LBB1914/10 only)  
2 VU-meter (LED's for -20, -6, 0 dB and Power ON)  
3 Input 1 (microphone) volume control  
4 Input 2 (microphone) volume control  
5 Input 3 (microphone) volume control  
6 Input 4 (microphone) volume control  
7 Line (music source) volume control  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Plena Mixer Amplifier | Installation and Operating Manual | About the mixer amplifier  
en | 9  
1.2 Controls and connections (rear)  
7
8
9
10  
11  
12  
13 14  
19  
Out  
In  
115V  
230V  
L
Tel/Emer.  
0
R
Inc  
CD  
Aux  
Line Out 1V  
Mic/Line  
0
2
+
3
GND  
GND  
1
+
Call/Mix  
70V  
Cal Only Mix Only 24VDCIn  
100/70V 100/70V 0  
1
2
2
3
Mic/Line  
100V  
0
0
8
0
0
Chime  
1
3
5
4
1
2
3
4
1
2
3
4
5
4
5
6
4
5
6
15  
16 17 18  
Zone 1 Zone 2  
Call/Mix  
Cal Only Mix Only 24VDCIn  
100/70V 100/70V 0  
100/70V/8 100/70V  
0
0
100/70V  
0
0
Only for LBB1914/10  
15  
Figure 1.3  
1 Chime ON/OFF switch  
12 Line output (XLR)  
2 Priority microphone input (5-pole DIN/balanced  
with Phantom power)  
13 Tape output (2x phono connectors)  
14 Insertion input/output (2x phono connectors)  
3 Input 1 microphone input (6.3 mm phono jack/  
balanced with Phantom power)  
15 Loudspeaker output terminals and 24 Vdc power  
supply terminals  
4 Microphone input (XLR/balanced with Phantom  
power in microphone mode)  
16 Mains connector (3-pole)  
17 Earth connection screw  
5 Microphone input (6.3 mm phono jack/balanced)  
6 Input Mic./Line switch  
7 Emergency connection input terminals  
8 Emergency volume pre-set  
9 CD input (2x phono connectors)  
10 Tape input (2x phono connectors)  
11 Auxiliary input (2x phono connectors)  
18 Mains fuse  
LBB1903 T1A (230 Vac) / T2A (115 Vac)  
LBB1906 T1.6A (230 Vac) / T3.15A (115 Vac)  
LBB1912 T2.5A (230 Vac) / T5A (115 Vac)  
LBB1914 T2.5A (230 Vac) / T5A (115 Vac)  
19 Mains voltage 115/230 V switch  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Plena Mixer Amplifier | Installation and Operating Manual | Internal settings  
en | 10  
2 Internal settings  
Mic. 3  
Mic. 4  
VOX  
V
7 0  
Mic. 2 Mic. 1  
V 0 1 0  
1
2
70V  
3
1
2
100V  
3
Mic.  
3
Mic.  
4
VOX  
Mic.  
2
Mic.  
1
JP802  
LBB1903/10  
LBB1906/10  
LBB1912/10  
VR401  
1
2
OFF  
3
1
2
ON  
3
Figure 2.1  
Mic. 3  
Mic. 4  
VOX  
Mic. 2 Mic. 1  
2 0 9 J P  
Mic.  
3
Mic.  
4
VOX  
Mic.  
2
Mic.  
1
1
2
3
1
2
3
70V/100V  
8 Ohm  
JP902  
VR401  
1
2
OFF  
3
1
2
ON  
3
LBB1914/10  
1
2
100V  
3
1
2
70V  
3
JP901  
Figure 2.2  
2.1 Setting the VOX for microphone input 1  
Input 1 has the option of a voice-controlled priority (VOX), which will overrule all other inputs when it recognizes  
a voice signal. To activate this function, set the VOX-jumper (JP406) to ON.  
2.2 Setting the speech filters  
The speech intelligibility can be improved by cutting off the lower frequencies of the signal. To activate this filter for  
each microphone input, set the respective filter jumper (JP401 for input 1, JP402 for input 2, JP403 for input 3 and  
JP405 for input 4) to ON.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Plena Mixer Amplifier | Installation and Operating Manual | Internal settings  
en | 11  
2.3 Setting the chime volume  
Adjusting the potentiometer VR401 changes the volume of the chime attention signal, preceding a priority call. Be  
careful not to adjust VR701; this is a power amplifier factory adjustment.  
2.4 Setting the output voltage for LBB1903, LBB1906 and LBB1912  
Direct outputs for 70 V, 100 V and low impedance (8 Ohm) loudspeakers are provided. Jumper JP802 sets the Call  
Only and Mix Only outputs to 70 V or 100 V output. These outputs are controlled by a priority relay. The Call  
Only output only provides priority announcements, while the Mix Only output just provides the mixed signals and  
switches off at priority calls.  
2.5 Setting the output voltage for LBB1914  
Jumper JP901 sets the Call/Mix, Zone 1, Zone 2, Call Only and Mix Only outputs to 70 V or 100 V output. Setting  
JP902 can also set the direct Call/Mix output to 8 Ohm for low impedance loudspeakers. The Call Only and Mix  
Only outputs are controlled by a priority relay. The Call Only output only provides priority announcements, while  
the Mix Only output just provides the mixed signals and switches off at priority calls. The zone selection buttons  
control the outputs of Zone 1 and 2, but priority announcements are always routed to these zones.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Plena Mixer Amplifier | Installation and Operating Manual | Installation in rack  
en | 12  
3 Installation in rack  
r
Ple  
t
na  
M
i
i
xe  
-  
4
3  
r
V  
Am  
p
/
lif  
i
e
r
0
/  
d
B
B
B
2
-6  
1
1
V  
3  
d
R
v  
-2  
0
d
/
0  
0  
2
4
/
7
V
1
0
0
P
o
r
w
s  
e
r
Se  
r
le  
c
t
3
CD  
A
U
X
L
in  
e
Mas  
t
e
r
+
1
+
Figure 3.1  
The mixer amplifier is delivered for tabletop use, but you can mount it in a 19" rack.  
If you mount the amplifier in a rack, you must:  
ensure that the unit does not exceed the overheating temperature (45 °C ambient).  
use the mounting brackets which can be ordered by Bosch (LBC 1901/00).  
remove the 4 feet from the bottom of the unit. Without the feet the unit is 2U high.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Plena Mixer Amplifier | Installation and Operating Manual | External settings and connections  
en | 13  
4 External settings and connections  
4.1 Connect the DC supply (battery)  
1
15  
V
/
2
3
0V  
A
con  
Ra  
p
p
te  
ara  
ne  
d i  
r : 4  
tu  
n
p
0
s
d
u
0
d
e
or  
p
t
owe  
liv  
23  
e
re  
0
cte  
d
V
f
Call  
70  
V
A
/Mi  
x
-
Cal  
l
Onl  
V0  
y
8
0
Mi  
x
O
n
l
y
10  
24VD  
0
/7  
0
V
C
0
In  
10  
0
/70  
V
0
T
e
l/Em  
0
L
er  
.
R
0
2
C
D
O
In  
ut  
C
hi  
m
Au  
x
e
1-  
4
Li  
ne  
-3  
.5  
O
ut  
1V  
In  
M
ic  
c
/L  
ine  
W
arn  
M
ic  
/L  
in  
i
1
n
e
g
2
Th  
1
1
5V  
i
/23  
0
s
V
a
pp  
3
Ra  
wer  
Ap  
par  
atu  
s
te  
ted  
aratus  
inp  
ut  
po  
conn  
del  
r
ive  
red  
ec  
:
4
d
C
00  
VA  
fo  
4
al  
l/M  
ix  
2
30  
V-  
100  
m
V
0
70  
Ca  
l
u
V
s
t
0
O
n
ly  
8
M
ix  
0
O
nl  
1
0
y
24  
VD  
0
/
7
0
V
C
In  
0
1
0
0
/
7
0
V
0
Wa  
Th  
is  
rn  
ap  
ing  
par  
atus  
mu  
st  
be  
ea  
rth  
ed  
-
+
F
LBB1903 (30W); F=F5A  
LBB1906 (60W); F=F8A  
LBB1912 (120W); F=F15A  
LBB1914 (120W); F=F15A  
-
12  
+
V
D
C
12  
V
D
C
Figure 4.1  
The mixer amplifier has a 24 Vdc input (terminal screw), which you can use to connect a back up power supply, e.g.  
batteries. You can earth the unit to increase the electrical stability of the system.  
Caution  
The connection cable must have an in-line fuse. Use the type of fuse as mentioned in the illustration.  
4.2 Priority microphone  
T
el  
/Emer  
L
.
0
R
0
2
C
D
O
In  
u
t
C
hime  
A
ux  
1
Li  
ne  
-
-3  
.5  
2
O
ut  
4
1V  
In  
Mi  
c
c
/Li  
n
e
Mi  
c
/Li  
1
n
e
2
11  
5
V/2  
30V  
3
R
po  
A
p
onn  
at  
w
pa  
ed  
ra  
te  
inp  
tu  
s
de  
for  
ut  
0V  
c
liv  
er  
30V  
e
r
ec  
:
4
ed  
0
d
Ca  
A
2
4
ll  
/M  
ix  
-
1
00  
V
0
7
0
C
a
V
ll  
O
0
nl  
y
8
Mi  
x
O
0
nl  
10  
0/70  
y
2
4
V
D
V
C
0
In  
100/70  
V
0
Wa  
rn  
in  
g
ar  
at  
T
h
is  
app  
us  
m
u
st  
b
e
e
a
rth  
ed  
GND  
GND  
6.3 mm phono jack  
180 5-pole DIN  
180 3-pole XLR  
Figure 4.2  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Plena Mixer Amplifier | Installation and Operating Manual | External settings and connections  
en | 14  
Microphone 1 input has a 5-pole DIN (for a 3 or 5-pole DIN microphone) and a 6.3-mm phone jack connector  
wired in parallel. Only when connecting a microphone with a priority contact on pin 4 and 5 of the 5-pole DIN  
connector (2), this input has priority over all inputs except the emergency input. This microphone input can be  
included with a voice controlled circuit (VOX) which will overrule all the other input signals. How to activate the  
VOX is described in §2.1.  
Note  
Only use one of the two connection possibilities of each microphone input.  
4.3 Chime ON/OFF-switch  
Te  
l/  
L
E
0
me  
r.  
R
0
2
C
D
O
In  
u
t
1
C
h
ime  
Au  
x
1
L
in  
-
-3  
.5  
e
O
u
4
t
1
V
In  
M
c
ic  
/L  
in  
e
M
ic  
/L  
in  
1
e
2
1
1
5
V
/2  
3
0
V
3
Ap  
Rat  
po  
p
e
e
ar  
a
tu  
ted  
d
r
in  
p
00  
s
ut  
c
onn  
d
e
r
w
li  
v
er  
0
e
c
e
:
d
V-  
4
C
fo  
a
VA  
2
3
4
ll/  
M
ix  
1
0
0
V
0
70V  
C
a
ll  
O
0
n
ly  
8
M
ix  
O
0
nl  
y
1
0
0/  
70  
2
4
V
DC  
V
0
In  
1
0
0
/7  
0
V
0
W
This  
a
rn  
in  
g
ar  
app  
at  
u
s
m
u
s
t
b
e
ea  
rt  
hed  
Figure 4.3  
Depending on the position of the chime ON/OFF-switch (1), switching on microphone 1 will activate the chime.  
The default chime volume is -8 dB (40 V), which will be sufficient in most applications. The volume can be altered  
using the potentiometer VR401 on the main PCB of the unit (see §2.3).  
Note  
Only when connecting a 5-pole DIN microphone to the 5-pole DIN connector of microphone input 1 the  
chime can be activated.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Plena Mixer Amplifier | Installation and Operating Manual | External settings and connections  
en | 15  
4.4 Microphone inputs  
6
6
T
el  
/E  
0
L
mer  
.
R
0
2
CD  
T
el  
Out  
In  
/
L
Eme  
0
Ch  
im  
Au  
x
e
r
.
1
-
4
Line  
Mi  
-3  
.5  
Ou  
t
1
V
Inc  
c/L  
c/L  
ine  
Mi  
1
ine  
2
11  
5V  
/23  
0V  
R
3
Ra  
we  
Ap  
pa  
ted  
r
rat  
ted  
inp  
us  
po  
ut  
40  
co  
nn  
de  
live  
red  
23  
ec  
:
Ca  
0V  
for  
4
ll/  
M
A
0V  
-
ix  
1
0
0
V
0
7
0
Ca  
ll  
V
0
On  
ly  
M
ix  
8
O
nly  
0
1
0
2
4
VD  
0
/
7
0
V
C
0
I
n
1
0
0
/
7
0
V
0
0
2
C
D
War  
is ap  
nin  
O
In  
g
Th  
u
t
p
aratu  
s
m
ust  
be  
ea  
rth  
ed  
C
h
im  
A
ux  
e
1-  
4
L
ine  
-3  
.5  
O
ut  
1V  
In  
M
ic/  
c
L
ine  
Mic/  
Li  
ne  
2
3
4
1
Figure 4.4  
Dependent on the microphone choose between the XLR with Phantom power and the 6.3 mm phono jack  
connector. Use an extension cable (1) if necessary. When using input 3 or 4 to connect microphones, set the  
switches (6) to Mic. When using these inputs as line-inputs, set the switches (6) to Line. To cut-off the lower  
frequencies of the signal, activate the speechfilters on the PCB (see §2.2).  
4.5 Emergency input  
8
T
e
l/E  
0
L
m
er  
.
R
0
2
CD  
Ou  
t
Ch  
im  
Au  
x
e
1-  
4
Lin  
e
Ou  
-3  
.5  
I
n
t
1
V
In  
c
M
ic/  
Lin  
e
Te  
M
ic/  
1
Line  
l
/
L
E
0
mer  
2
.
115  
rat  
V/2  
30  
V
3
Ra  
we  
Ap  
pa  
ec  
ted  
r
inp  
us  
po  
ut  
40  
co  
nn  
de  
for  
live  
23  
:
ted  
red  
0V  
Ca  
0V  
4
ll/  
M
A
ix  
-
1
0
0
V
0
7
0
Ca  
ll  
V
0
1
O
nly  
M
ix  
8
O
nly  
0
0
0
2
4V  
D
/
7
0
C
V
0
I
n
1
0
0
/
7
0
V
0
Wa  
is  
rn  
ing  
ara  
Th  
R
a
pp  
tus  
mu  
st  
be  
ea  
rth  
ed  
0
2
CD  
Ch  
im  
A
e
1-  
4
-
3
.5  
1
2
Figure 4.5  
The emergency input is for emergency announcements/signals and obviously has the highest priority (all other  
inputs are overruled). The emergency volume -which cannot be affected by the master volume control (11) - can be  
set at 8, using a screwdriver. It can not be set to zero.  
Caution  
A connection to a telephone network must always be made via a telephone coupler that provides adequate  
isolation between the telephone network (PBX) and the Plena system. The telephone coupler must also meet  
all relevant requirements for this type of communication equipment as imposed by law and/or responsible  
telecommunication organisations in the country of use. Never try to make a direct connection between the  
telephone network and the mixer amplifier.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Plena Mixer Amplifier | Installation and Operating Manual | External settings and connections  
en | 16  
4.6 Music source inputs  
10  
13  
T
e
l/E  
0
L
m
er  
.
R
0
2
C
D
O
In  
ut  
C
hi  
m
e
Au  
x
1-  
4
Li  
ne  
-3  
.5  
O
ut  
1V  
Inc  
M
ic  
/L  
in  
e
M
ic  
/L  
ine  
1
2
Te  
1
15  
V/  
23  
el  
l
/
0
V
E
0
m
3
Ra  
Ap  
par  
at  
c
on  
ne  
cte  
e
te  
er  
d
r
.
inpu  
00  
us  
d
fo  
pow  
t
ive  
:
4
d
re  
d
Ca  
V
A
r
4
ll/  
M
2
30  
ix  
V
-
100  
V
0
70  
V
Ca  
ll  
0
O
nl  
y
8
M
ix  
0
O
n
ly  
10  
0/  
70  
2
4
VD  
V
C
0
I
n
10  
0/  
70  
V
0
W
Th  
is  
ar  
ni  
pp  
ng  
ar  
atu  
a
R
s
m
us  
t
b
e
e
ar  
the  
d
0
2
C
D
C
h
im  
e
A
u
x
1
-
-3  
L
i
n
e
O
u
4
.
5
t
M
i
c/L  
I
n
i
ne  
c
M
1
ic/L  
in  
2
3
RECORD  
CD  
4
PLAYBACK  
TUNER  
LBB1961  
P
L
E
N
A
B
G
M
s
o
u
rc  
e
Po  
we  
r
R
e
pe  
a
t
P
r
o
gr  
a
m
r
Fo  
lde  
CD  
/M  
P3  
TA  
FM  
S
/
AM  
M1  
/
6
P
E
M2  
/
7
M3  
/
8
M4  
/
9
c
an  
M5  
/
1
0
Pro  
g
ra  
m
Figure 4.6  
When using a CD player, tape recorder or tuner for background music, connect the line-out connectors of the music  
source to the appropriate line-in connectors of the mixer amplifier (e.g. the tape recorder must be connected to the  
tape source input (10)). When using a tape recorder to record the output of the amplifier, connect the line-in  
connectors of the tape recorder to the line-out connector (13) of the mixer amplifier.  
4.7 Connecting the line output  
12  
Te  
l/  
E
0
m
e
r.  
L
Te  
l/E  
0
L
mer  
.
R
0
2
CD  
Ou  
In  
t
R
Chi  
me  
Aux  
1-  
4
Li  
ne  
-3  
.5  
Out  
1V  
In  
c
Mi  
c/  
Line  
M
ic/  
Line  
1
0
2
2
CD  
115  
ra  
V/  
23  
0V  
3
Ra  
ted  
Ap  
pa  
inp  
:
tus  
pow  
er  
ut  
0V  
co  
nn  
ect  
de  
liv  
ere  
d
40  
ed  
for  
23  
Ca  
4
ll/Mi  
A
0V  
x
-
1
0
0
V
Chime  
0
7
0
Ca  
ll  
V
0
O
nly  
8
M
ix  
0
O
n
ly  
1
0
2
4
VDC  
0
/7  
0
V
0
I
n
1
0
0
/7  
0
V
0
1
-
-3  
.5  
ine  
W
Th  
is  
ar  
ni  
O
ng  
4
ut  
a
ppa  
ratus  
1V  
m
us  
t
be  
ea  
rth  
ed  
Inc  
M
ic/  
L
ine  
1
M
ic/  
L
i
n
2
P
3
le  
na  
Bo  
o
s
te  
r
Am  
p
lif  
0
ie  
r
d
B
B
B
-6  
-2  
d
d
0
4
P
o
we  
r
Figure 4.7  
The line output (12) is an output for connecting additional PA amplifiers (such as the Plena Booster Amplifiers).  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Plena Mixer Amplifier | Installation and Operating Manual | External settings and connections  
en | 17  
4.8 Connecting loudspeakers  
LBB1903/10  
LBB1906/10  
LBB1912/10  
T
e
l/E  
0
L
me  
r.  
R
0
2
CD  
Ou  
t
Ch  
im  
Au  
x
e
1-  
4
-
.5  
Lin  
e
3
O
n
ut  
1V  
Mi  
c/L  
Inc  
c/L  
ine  
Mi  
1
ine  
2
11  
5V  
/23  
0V  
100V  
3
po  
Ap  
pa  
rat  
ted  
ate  
d
r
i
:
us  
np  
ut  
40  
co  
nn  
de  
we  
ec  
live  
red  
23  
Ca  
0V  
for  
4
ll/M  
A
0V  
ix  
-
10  
0
V
0
70  
V
Cal  
On  
ly  
100V  
0
0
8
Mix  
On  
0
ly 24  
VD  
10  
0/70  
V
CI  
n
0
10  
0/7  
V0  
0
Wa  
Th  
rni  
a
ng  
pp  
is  
ara  
tus  
mu  
st  
b
e
e
arth  
ed  
70V  
70V  
0
70V  
JP802  
100V  
Call/Mix  
Call Only Mix Only 24VDCIn  
100/70V  
100/70V  
Call/Mix  
70V  
Call Only Mix Only 24VDCIn  
8 Ohm  
8 Ohm  
0
100V  
0
70V  
0
8
0
0
0
100V  
0
0
8
0
100/70V  
0
100/70V  
0
0
Call Only  
0
0
0
8
Ohm  
Mix Only  
0
4
4
Ohm  
Ohm  
LBB1903/10  
LBB1906/10  
LBB1912/10  
24V  
+
24V  
Call Active  
-
8
8
Ohm  
Ohm  
8
8
Ohm  
Ohm  
Call/Mix  
direct out  
100V  
Call/Mix  
direct out  
70V  
Call Only  
100/70V  
Mix Only  
100/70V  
Call/Mix direct out  
8
Ohm  
Figure 4.9  
Call Only  
0
0
0
0
LBB1914/10  
Te  
l/E  
0
L
me  
r.  
R
0
Zone 1  
Call/Mix  
0
0
2
CD  
Ou  
t
Ch  
im  
Au  
e
x
1-  
4
-
.5  
Lin  
e
3
O
ut  
I
n
1V  
Mi  
c/  
Inc  
c/L  
Lin  
e
Mi  
1
ine  
JP901  
100V  
2
11  
5V  
/23  
0V  
3
Ra  
we  
r
Ap  
para  
ted  
i
np  
tus  
ted  
po  
ut  
40  
co  
nn  
ec  
de  
live  
red  
23  
0V  
Ca  
:
ll/  
M
ix  
0V  
for  
4
A
1
0
0
-
V
0
Ca  
ll  
Z1 Front  
7
0
V
O
n
l
y
0
Mi  
x
8
O
n
ly  
0
2
4V  
D
1
0
0
/
7
0
C
I
n
V
0
1
0
0
/
7
0
V
0
100V  
70V  
War  
is  
ning  
a
Th  
pp  
ara  
tus  
mu  
JP902  
100/70  
st  
b
e
e
art  
he  
d
70V  
8 Ohm  
8 Ohm  
0
Zone  
100/70V  
1
Zone  
2
Zone  
1
Zone  
2
Call/Mix  
Call Only Mix Only 24VDCIn  
Call/Mix  
100/70V/8  
Call Only Mix Only 24VDCIn  
Call/Mix  
0
100/70V/8  
0
0
100/70V  
0
100/70V  
0
100/70V  
0
0
100/70V  
0
100/70V  
0
100/70V  
0
100/70V  
0
0
8
Ohm  
Ohm  
0
Zone 2  
Call/Mix  
0
4
0
0
Z2 Front  
0
4
Ohm  
Mix Only  
0
8
8
Ohm  
Ohm  
8
8
Ohm  
Ohm  
24V  
+
Call Active  
LBB1914/10  
24V  
Call/Mix  
direct out  
100/70V  
Zone  
100/70V  
1
Zone  
100/70V  
2
Call Only  
100/70V  
Mix Only  
100/70V  
-
Call/Mix direct out  
8
Ohm  
Figure 4.8  
Figure 4.10  
4.8.1Constant voltage loudspeakers  
The mixer amplifier can drive 100 V constant voltage loudspeakers at full power (100 V) or half power (70 V).  
Connect the loudspeakers in parallel and check the loudspeaker polarity for in-phase connection. The summed  
loudspeaker power should not exceed the rated amplifier power. Ensure that the jumper(s) for loudspeaker voltage  
selection is / are properly set (see §2.4).  
You can use the Call Only output for 3-wire remote volume control override. In this case, ensure that the selected  
voltage for the Call Only output is the same as for the direct output or the zone outputs.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Plena Mixer Amplifier | Installation and Operating Manual | External settings and connections  
en | 18  
4.8.2Low impedance loudspeakers  
Connect low impedance loudspeakers to the 8 Ohm/0 terminals. This output can deliver the rated output power  
into an 8 Ohm load. Connect multiple loudspeakers in a series/parallel-arrangement to make the combined  
impedance 8 Ohm or higher. Check the loudspeaker polarity for in-phase connection. Ensure that the jumper(s) for  
loudspeaker voltage selection is / are properly set (see §2.5).  
4.9 Mains connection  
Te  
l/E  
0
L
m
er  
.
R
0
2
C
D
O
In  
ut  
C
hi  
m
A
ux  
e
1-  
4
Line  
Ou  
-3  
.5  
t
1V  
Inc  
M
ic/  
Li  
ne  
M
ic/  
Li  
1
ne  
2
11  
5V  
/23  
0V  
3
Ra  
we  
Ap  
co  
te  
pa  
ec  
ra  
d
r
tu  
in  
:
s
pu  
40  
de  
po  
t
nn  
liv  
ere  
30  
te  
d
-
d
Ca  
0V  
fo  
r
4
ll/M  
A
2
ix  
V
10  
0V  
0
7
0V  
Ca  
ll  
0
O
n
ly  
8
Mi  
x
0
O
n
ly  
100  
24  
VD  
/70  
V
C
0
I
n
10  
0/70  
V
0
W
Thi  
arn  
in  
g
s
a
pp  
ar  
at  
us  
mu  
st  
b
e
ea  
rth  
ed  
I
GN  
&
QUALI  
LAND  
LIP  
S
H
T
Y
O
L
1
1
5V/  
23  
0
V
App  
Ra  
t
a
r
ed  
at  
c
inp  
us  
u
c
d
fo  
p
t
o
n
e
r
o
we  
live  
ne  
r
r
e
V-  
te  
d
d
:
4
00  
V
A
2
30  
Cal  
l
O
n
ly  
M
ix  
On  
ly  
00  
2
4
/
70V  
VD  
C
0
1
00  
/
70V  
0
Wa  
Th  
is  
r
nin  
g
a
p
pa  
ra  
tus  
m
us  
t
b
e
ea  
r
thed  
Figure 4.11  
Use the supplied mains cord to connect the system to the mains supply.  
Note  
If necessary set the switch 115/230 V to the required voltage using a sharp object, e.g. a small screwdriver.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Plena Mixer Amplifier | Installation and Operating Manual | Operation of mixer amplifier  
en | 19  
5 Operation of mixer amplifier  
2
3
4
8
9
Only for LBB1914/10  
Plena Mixer Amplifier  
1
3
2
4
Select  
CD  
0 dB  
-6 dB  
AUX  
Master  
Zone 1  
Zone 2  
-20 dB  
Line  
Power  
710
1
5
6
11  
12  
13  
Figure 5.1  
5.1 Source selection  
Use the music source selector (8) to select one of the connected music sources.  
Use the input volume controls (3, 4, 5, 6 and 7) to balance the sound level of the microphone inputs and the  
background music.  
5.2 Volume and tone control  
Use the master volume control (11) to control the volume of the music/microphone mix.  
The treble and bass tone controls (9 and 10) affect the microphones as well as the music.  
5.3 Zone selection (LBB1914/10 only)  
Use the zone selection buttons (12 and 13) to route the music/microphone mix from the amplifier output to  
loudspeaker zone 1 and/or loudspeaker zone 2. Priority announcements, however, are always routed to both  
zones, irrespective of the position of the zone selection buttons.  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Plena Mixer Amplifier | Installation and Operating Manual | Technical data  
en | 20  
6 Technical data  
6.1 Electrical  
Mains voltage  
230/115 Vac, 10%, 50/60 Hz  
Max mains power consumption  
LBB1903/10  
100 VA  
200 VA  
400 VA  
LBB1906/10  
LBB1912/10, LBB1914/10  
Max mains inrush current  
LBB1903/10  
LBB1906/10  
LBB1912/10, LBB1914/10  
Battery voltage  
4.5 A/9 A (230/115 Vac)  
5 A/10 A (230/115 Vac)  
8 A/16 A (230/115 Vac)  
24 Vdc, +20%/-10%  
Max battery current  
LBB1903/10  
1.6 A  
3 A  
LBB1906/10  
LBB1912/10, LBB1914/10  
6 A  
6.2 Performance  
Frequency response  
Distortion  
50 Hz - 20 kHz (+1/-3 dB @ -10 dB ref. rated output)  
< 1% @ rated output, 1 kHz  
-8/+8 dB @ 100 Hz  
Bass control  
Treble control  
-8/+8 dB @ 10 kHz  
6.3 Inputs  
Input 1 (5-pin DIN, balanced with phantom power, 6.3 mm phone jack)  
Input 2 (3-pin XLR, balanced with phantom power, 6.3 mm phone jack)  
Sensitivity  
1 mV  
Impedance  
> 1 kOhm  
63 dB  
> 75 dB  
> 40 dB (50 Hz - 20 kHz)  
> 25 dB  
S/N (flat at max volume)  
S/N (flat at min volume/muted)  
CMRR  
Headroom  
Speech filter  
Phantom power supply  
VOX (input 1 only)  
-3 dB @ 315 Hz, high-pass, 6 dB/oct  
16 V via 1.2 kOhm  
attack time 150 ms  
release time 2 s  
Input 3 and 4 (3-pin XLR, balanced with phantom power, 6.3 mm phone jack)  
Sensitivity  
Impedance  
1 mV (microphone), 200 mV (line)  
> 1 kOhm (microphone)  
> 5 kOhm (line)  
S/N (flat at max volume)  
S/N (flat at min volume/muted)  
CMRR  
63 dB (microphone), 70 dB (line)  
75 dB  
> 40 dB (50 Hz - 20 kHz)  
> 25 dB  
Headroom  
Speech filter  
Phantom power supply  
-3 dB @ 315 Hz, high-pass, 6 dB/oct  
16 V via 1.2 kOhm (microphone)  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Plena Mixer Amplifier | Installation and Operating Manual | Technical data  
en | 21  
Music input (Cinch, stereo converted to mono)  
Sensitivity  
Impedance  
S/N (flat at max volume)  
S/N (flat at min volume/muted)  
Headroom  
200 mV  
22 kOhm  
> 70 dB  
> 75 dB  
> 25 dB  
Emergency / telephone (Screw, balanced)  
Sensitivity  
Impedance  
VOX  
100 mV - 1 V adjustable  
> 10 kOhm  
threshold 50 mV  
attack time 150 ms  
release time 2 s  
> 65 dB  
S/N (flat at max volume)  
Interconnection (Cinch)  
Nominal level  
Impedance  
1 V  
> 10 kOhm  
6.4 Outputs  
Master output 1 (3-pin XLR, balanced)  
Nominal level  
Impedance  
1 V  
< 100 Ohm  
Tape output (Cinch, 2x mono)  
Nominal level  
Impedance  
350 mV  
1.5 kOhm  
Interconnection (Cinch)  
Nominal level  
Impedance  
1 V  
< 100 Ohm  
Loudspeaker outputs (Screw, floating)  
Max/rated output power 70/100 V  
LBB1903/10  
LBB1906/10  
LBB1912/10, LBB1914/10  
8 Ohm output  
45 W/30 W  
90 W/60 W  
180 W/120 W  
LBB1903/10  
LBB1906/10  
16 V (30 W)  
22 V (60 W)  
LBB1912/10, LBB1914/10  
Output power @ 24 V battery operation  
31 V (120 W)  
-1 dB ref. rated power  
6.5 Environmental conditions  
Operating temperature range  
Storage temperature range  
Relative humidity  
-10 to +45 °C  
-40 to +70 °C  
< 95%  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Plena Mixer Amplifier | Installation and Operating Manual | Technical data  
en | 22  
6.6 General  
EMC emission  
acc. to EN 55103-1  
EMC immunity  
Acoustic noise level of fan  
Dimensions  
acc. to EN 55103-2  
< 40 dB SPL @ 1 m (LBB1912/10 and LBB1914/10 only)  
100 x 430 x 270 mm (19wide, 2U high)  
Weight  
LBB1903/10  
approx. 5 kg  
LBB1906/10  
LBB1912/10, LBB1914/10  
19mounting brackets  
approx. 8.5 kg  
approx. 10.5 kg  
LBC1901/00 (to be ordered separately)  
Bosch Security Systems | 2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
For more information visit  
© Bosch Security Systems B.V.  
Data subject to change without notice  
2003-09 | 3922 988 92883en  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Blodgett Convection Oven SC 7E User Manual
BodyCraft Flat Panel Television 410LP User Manual
Bosch Appliances Kitchen Entertainment Center DHL 755 B User Manual
Bosch Appliances TV DVD Combo E2600 User Manual
Bowers Wilkins Speaker ASW3000 User Manual
Briggs Stratton Portable Generator On Board Generator System User Manual
Broan Ventilation Hood 350 User Manual
Bushnell Camera Accessories 20 5105 User Manual
Cateye Bicycle EC UB200 User Manual
Cisco Systems Computer Hardware UC52016U4FXOK9 User Manual