		 WARNING   
					Marine Electrical Products   
					AC Rotary Switch Panel   
					2 Positions + OFF, 3 Pole   
					PN 8363   
					@ 
					It is not possible within the scope of these instructions to fully acquaint   
					the installer with all the knowledge of electrical systems that may be   
					necessary to correctly install this product. If the installer is not   
					knowledgeable in electrical systems we strongly recommend that an   
					electrical professional be retained to make the installation.   
					If either the switch front or back is to be exposed to water it must be   
					protected with a waterproof shield.   
					The switch must not be installed in explosive environments such as   
					gasoline engine rooms or battery compartments as the switches   
					are not ignition proof.   
					The vessel’s shore power cord must be disconnected form shoreside   
					power before installing this electrical switch.   
					If an inverter is installed on the vessel its power leads must be   
					disconnected at the battery before the panel installation. Be aware that   
					many inverters have a “sleep mode” in which their voltage potential   
					may not be detectable with measuring equipment.   
					@ 
					@ 
					Features   
					• Switches 2 - 120/240 V AC Sources   
					• Compact solution when circuit protection is provided elsewhere   
					• Allows connecting one of two different AC sources to one circuit   
					• Heavy duty industrial rated switches   
					• Intuitive function - One handed operation   
					• Green power available LED indicators   
					• Red reverse polarity LED indicators   
					@ 
					@ 
					• UL listed switches   
					Panel Specifications   
					@ 
					@ 
					If an AC Generator is installed aboard it must be stopped and rendered   
					inoperable before the switch is installed.   
					Verify that no other AC or DC source is connected to the vessel’s   
					wiring before the switch is installed.   
					Voltage Rating:   
					Panels are rated for 120 volts AC   
					Amperage Rating: 65 amp maximum service   
					Panel Material:   
					Primary Finish:   
					0.125” 5052-H32 Aluminum Alloy   
					Chemical Treatment per Mil Spec C-5541   
					Final Panel Finish: Graphite color 2 part textured Polyurethane   
					Maximum Wire Size:   
					Minimum Wire Size:   
					Terminal Recommended Torque:   
					6 AWG   
					12 AWG   
					40 lb-in.   
					Guarantee   
					Any Blue Sea Systems product with which a customer is not satisfied   
					may be returned for a refund or replacement at any time.   
					Inches   
					Millimeters   
					Overall Dimensions:   
					Mounting Centers:   
					Mounting Depth:   
					5-1/4 x 3-3/4   
					4-7/16 x 2-15/16 112.71 x 74.61   
					3-13/46 96.84   
					133.35 x 95.25   
					Blue Sea Systems Inc.   
					425 Sequoia Drive   
					Phone (360) 738-8230   
					Fax (360) 734-4195   
					Bellingham, WA 98226 USA   
					E-mail conduct@bluesea.com   
					
					Document 6632 Rev.B   
					Installation   
					The switch provides switching, but does not provide circuit protection.   
					It is not a substitute for a main circuit breaker.   
					1. Disconnect all AC and DC power   
					Disconnect all AC power originating on or off the vessel. This includes   
					inverters, generators, shore power attachments and any other device   
					capable of supplying AC power to the ship’s circuits.   
					Wire sizing chart   
					Use the wire sizing chart below to determine the minimum branch and   
					feed circuit wire sizes.   
					Disconnect the main positive DC cable from all batteries to eliminate   
					the possibility of a short circuit and to disable the inverter while   
					installing the switch.   
					2. Select mounting location and cut opening   
					Select a mounting location which is protected from water on the front   
					and back of the switch and is not in an area where flammable vapors   
					from propane, gas or lead acid batteries accumulate. AC rotary   
					switches are not ignition protected and may ignite such vapors.   
					Using the panel template provided, make a cut out in the mounting   
					surface where the distribution panel is to be mounted. Do not yet   
					fasten the panel to the mounting surface.   
					3. Install source 1, source 2 and output wires   
					Install the feed wires from AC Shore Power and AC Generator. Install   
					the output wires. Refer to the wire sizing chart to select the minimum   
					wire size. Connect wires as shown in the illustration. To avoid excess   
					wire temperatures when cooling may be limited, we recommend using   
					at least 12 gauge wire for 30A and 8 gauge wire for 50A.   
					4. Testing Connections   
					It is very important that the wiring be connected according to the   
					diagram. The line and neutral from each source must be paired   
					together and not connected such that the switch selects line from one   
					source and neutral from another. Verify the connections and see that   
					each connection is securely tightened, including the terminals for the   
					jumpers installed on the switch where no wires are attached.   
					Do not confuse the neutral current carrying wires (sometimes called   
					ground) with the green normally non-current carrying wires (sometimes   
					called grounding). These two wires must be connected only at the   
					source of power, nowhere else.   
					It is possible to verify the connections using an ohmmeter before power   
					is applied. These procedures take a little time, but are recommended,   
					especially if some elements of a previous installation might not have   
					been properly labeled or followed the expected color codes.   
					A double pole circuit breaker must be installed within 10 feet of the   
					shore power inlet, ahead of this switch. The measurement is made   
					along the conductors.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Installation (continued)   
					DOUBLE OR TRIPLE POLE CIRCUIT   
					BREAKER REQUIRED WITHIN TEN FEET   
					OF SHORE INLET BETWEEN AC SOURCE   
					SELECTOR SWITCH AND SHORE POWER   
					FROM AC   
					LINE 2   
					FROM AC   
					LINE 1   
					FROM AC   
					SHORE   
					NEUTRAL   
					FROM AC   
					NEUTRAL   
					GENSET   
					FROM AC   
					LINE 1   
					FROM AC   
					LINE 2   
					11   
					9 
					10   
					FROM AC   
					LINE 1   
					FROM AC   
					NEUTRAL   
					FROM AC   
					LINE 2   
					BACK VIEW   
					Wiring Diagram   
					AC Source Selector Panel   
					PN 8363 Shown   
					Panel Template   
					AC Source Selector Panel   
					PN 8363   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 | 
Beyerdynamic Microphone MC 910 User Manual
Billy Goat Vacuum Cleaner KD 50, KD 50C, KD 50T, KD 50CT, KD 55CKW User Manual
Blaupunkt Portable Radio Arizona DJ73 User Manual
Bosch Power Tools Saw 4212L User Manual
Braun Blender MR 4000 CA User Manual
Braun Coffeemaker KF 610 User Manual
Braun Thermometer IRT4020 User Manual
Bravetti Microwave Oven K5309H User Manual
Calibre UK Computer Monitor 30W User Manual
Century Computer Hardware A780FULLHD User Manual