682
OWNERS MANUAL
for
BOTTLED WATER
AIRPOT
COFFEE BREWERS
MODEL
8382
for
3 Gallon
and
5 Gallon
Plastic Bottles
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 8382 Brewer
PRINTED IN UNITED STATES OF AMERICA
p/n 75611 Rev. E ECN-12597
M682 040914 cps
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
Thank You for purchasing this
Bloomfield Industries appliance.
WARRANTY STATEMENT
SPECIFICATIONS
FEATURES & OPERATING CONTROLS
PRECAUTIONS & GENERAL INFORMATION 3
AGENCY APPROVAL INFORMATION
INSTALLATION
OPERATION
xi
1
2
Proper installation, professional
operation and consistent
maintenance of this appliance will
ensure that it gives you the very
best performance and a long,
economical service life.
3
4
5
CLEANING INSTRUCTIONS
TROUBLESHOOTING SUGGESTIONS
SERVICING INSTRUCTIONS
EXPLODED VIEWS & PARTS LISTS
WIRING DIAGRAM
8
This manual contains the
10
11
16
19
information needed to properly
install this appliance, and to use,
care for and maintain or repair the
appliance in a manner which will
ensure its optimum performance.
SPECIFICATIONS
VOLTS WATTS
MODEL
STYLE
AMPS
1ø
POWER SUPPLY
CORD
8382
8382OR
AIRPOT BREWER
120 VAC 1800 W
120 VAC 1500 W
15 A
NEMA 5-15P
NEMA 5-15P
8382CA k with FAUCET
12.5 A
k meets Canadian standards
1
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURES AND OPERATING CONTROLS
Fig. 1 Features & Operating Controls
2
Download from Www.Somanuals.com. All Manuals Search And Download.
PRECAUTIONS AND GENERAL INFORMATION
WARNING: Electric Shock Hazard
All servicing requiring access to non-insulated components must be performed by qualified
service personnel. Do not open any access panels which require the use of tools. Failure to
heed this warning can result in electrical shock.
WARNING: Injury Hazard
All installation procedures must be performed by qualified personnel with full knowledge of all
applicable electrical and plumbing codes. Failure could result in property damage and
personal injury.
WARNING Electric Shock Hazard
Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a
plumbing line will provide such a ground. Electrical shock will cause death or serious Injury.
WARNING: Burn Hazard
This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from
contact with dispensed liquids.
This appliance is intended for commercial use only.
CAUTION: Equipment
Electrical Damage
This appliance is intended for use to brew beverage products for
human consumption. No other use is recommended or
authorized by the manufacturer or its agents.
DO NOT plug in or energize this
appliance until all Installation
This appliance is intended for use in commercial establishments, Instructions are read and followed.
where all operators are familiar with the appliance use,
limitations and associated hazards. Operating instructions and
warnings must be read and understood by all operators and
users.
Damage to the Brewer will occur if
these instructions are not followed.
CAUTION:
Burn Hazard
Except as noted, this piece of equipment is made in the USA
and has American sizes on hardware. All metric conversions
are approximate and can vary in size.
Exposed surfaces of the
appliance, brew chamber and
decanter may be HOT to the
touch, and can cause serious
burns.
The following trouble shooting, component views and parts lists
are included for general reference, and are intended for use by
qualified service personnel.
This manual should be considered a permanent part of this
appliance. The manual must remain with the appliance if it is
sold or moved to another location.
AGENCY APPROVAL INFORMATION
This brewer is
and
listed under UL file E9253.
This brewer meets
Standard 4 only when installed,
E9253
STD 4
E9253
operated and maintained in accordance with the enclosed
instructions.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION
IMPORTANT:
Unpack the unit. Inspect all components for completeness and
condition. Ensure that all packing materials have been removed
from the unit.
To enable the installer to make
a quality installation and to
minimize installation time, the
following suggestions and tests
should be done before the
actual unit installation is started:
Verify that the Spray Head Gasket (#33) and Spray Disk (#34)
are properly installed.
LEVELING THE UNIT
Verify that an adjustable leg is installed at each corner of the
brewer.
CAUTION: Equipment
Electrical Damage
Set Brewer in its operating location. Level the Brewer. A spirit
level should be placed on the top of the unit, at the edge, as a
guide when making level adjustments.
DO NOT plug in or energize this
appliance until all Installation
Instructions are read and
followed. Damage to the
Brewer will occur if these
instructions are not followed.
Level the unit from left to right and front to back by turning the
adjustable feet. Be sure all four feet touch the counter to prevent
tipping.
FILL WATER TANK
Check the bottle ring for lint or packing materials. Wipe the
interior of the bottle ring with a cloth dampened with clean water.
CAUTION: Unstable
Equipment Hazard
Brewer is designed to use a 3 gallon or 5 gallon plastic water
bottle. Carefully insert a fresh water bottle into the bottle ring.
It is very important for safety
and for proper operation that the
brewer is level and stable when
standing in its final operating
position. Provided adjustable,
non-skid legs must be installed
at each corner of the unit.
Failure to do so will result in
movement of the brewer which
can cause personal Injury and/
or damage to brewer.
Wait 30 seconds, or until all bubbling in the bottle stops, then
drain water from the hot water faucet until all air is purged from
the tank.
ELECTRICIAN’S INSTALLATION INSTRUCTIONS
REFER TO ELECTRICAL SPECIFICATIONS - Page 1
Check the nameplate to determine correct electrical service
required for the Brewer to be installed.
IMPORTANT: Before connecting to electricity, make sure a
bottle of water is installed on the bottle ring, and all air has been
bled from the water tank
Model 8382 is equipped with a cord and plug. It requires a 115 -
125 volt 20 amp circuit (50/60 Hz, 2 wire plus ground, with NEMA
5-15R or 5-20R Receptacle).
WARNING ELECTRIC
SHOCK HAZARD:
IMPORTANT:
Brewer must be plugged into a
properly grounded electrical
receptacle to prevent possible
shock hazard. DO NOT
assume a plumbing line will
provide such a ground.
Supply power must match nameplate for voltage and phase.
Connecting to the wrong voltage will damage the brewer or result
in decreased performance. Such damage is not covered by
warranty.
IMPORTANT: The ground prong of the plug is part of a system
designed to protect you from electrical shock in the event of
internal damage. Never cut off the ground prong nor twist a
blade to fit an existing receptacle. Contact a licensed electrician
to install the proper circuit and receptacle.
Electrical shock will cause death
or serious injury.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
WARNING:
START-UP
Personal Injury
For initial start-up, or if the brewer has not been used for an
extended period of time:
5 Gallon water bottle can weigh
up to 50 pounds. Install bottle
carefully. Injury can result from
improper lifting technique or
from attempting to lift a full bottle
without adequate physical
ability.
♦ Be sure spray disk and brew gasket are properly installed
in the brew head.
♦ Install a fresh bottle of water in the bottle ring.
♦ Allow basin and tank to fill.
♦ Plug unit into a properly grounded electrical receptacle.
♦ Draw water from the hot water faucet until all air is purged
from the tank.
NOTE: This brewer will not function as a “pour-over” brewer. A
water bottle with an adequate amount of water must be installed
for the brewer to operate.
CAUTION: Equipment
Electrical Damage
DO NOT manually fill brewer
through bottle ring.
Once plugged into electrical power, the heating elements will
begin heating the water in the tank. When the water has reached
the proper temperature, the “READY TO BREW” light will glow.
IMPORTANT: Use only 3 gallon
or 5 gallon plastic water bottle.
IMPORTANT:
Tank must be full of water
before connecting brewer to
electrical power.
Heating elements will be
damaged if allowed to operate
without being fully submerged in
water. Damage caused by
operating the brewer without
water in the tank is NOT
COVERED BY WARRANTY.
IMPORTANT:
This appliance is NOT designed
to be used as a pour-over
brewer. Operation without a
water bottle with an adequate
amount of water in place will
produce very little or no brewed
coffee.
IMPORTANT:
When installing water bottle, be
careful to not overflow the basin
pan. DO NOT fill the basin pan
prior to installing the water
bottle.
Fig 2. Brewer Operation Diagram
5
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION (continued)
HI-LIMIT
THERMOSTAT
WATER HEATER
Water temperature is sensed by a
thermobulb inserted into the water tank. This
temperature signal is fed to the thermostat,
which controls line power to the heating
element.
THERMOBULB
The setpoint temperature is adjustable at the
thermostat.
HEATER
ELEMENT
THERMOSTAT
The element is protected from over-
temperature by a hi-limit thermostat.
Fig. 3 Heat Control Diagram
WATER FLOW
AUTOMATIC OPERATION
Water is supplied to the hot water tank by a
bottle inserted in the bottle ring. Water will
flow from the bottle into the basin pan until
the water level reached the open mouth of
the bottle.
Pressing BREW button energizes the
solenoid valve, allowing heated water from
the hot water tank to flow through the spray
head into the brew chamber.
The length of time the solenoid is open is
controlled by the timer.
HOT WATER FAUCET
The hot water faucet draws heated water
from the water tank.
Fig. 4 Water Flow Diagrams
6
Download from Www.Somanuals.com. All Manuals Search And Download.
BREWING COFFEE
PREPARATION
CAUTION:
Burn Hazard
Place one (1) genuine Bloomfield paper filter in the brew chamber.
Add a pre-measured amount of fresh coffee grounds.
Exposed surfaces of the
brewer and brew chamber
may be HOT to the touch,
and can cause serious
burns.
Gently shake the brew chamber to level the bed of grounds. Slide
the brew chamber into place under the brew head.
CAUTION:
Burn Hazard
To avoid splashing or over-
flowing hot liquids,
ALWAYS place an empty
airpot under the brew
chamber before starting
the brew cycle. Failure to
comply can cause serious
burns.
Fig. 5 Brew Chamber
AUTOMATIC OPERATION
BE sure “READY TO BREW” light is lit.
Place an EMPTY airpot in place under the brew chamber.
CAUTION:
Press the “BREW” switch. The solenoid will open for an amount of
time determined by the timer setting, admitting a measured quantity
of hot water into brew head, where it will spray over the bed of
grounds.
Burn Hazard
After a brew cycle, brew
chamber contents are
HOT. Remove the brew
chamber and dispose of
used grounds with care.
Failure to comply can
cause serious burns.
When the flow and all dripping stops, the coffee is ready to serve.
Discard the contents of the brew chamber and rinse it in a sink.
When the ”READY TO BREW” light comes on, the brewer is ready
for another brew cycle.
NOTE: Use of the hot
water faucet will not affect
the volume of water
delivered for a brew.
However, overuse of the
faucet during a brew may
lower the temperature of
the brew water.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING INSTRUCTIONS
CAUTION:
Burn Hazard
PROCEDURE: Clean Coffee Brewer
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
Brewing and serving
temperatures of coffee are
extremely hot.
Hot coffee will cause
serious skin burns.
FREQUENCY:
TOOLS:
Daily
Mild Detergent, Clean Soft Cloth or Sponge
Bristle Brush.
CAUTION:
Electric Shock
Hazard
1. Disconnect brewer from electric power.
Allow brewer to cool before cleaning.
Do not submerge or immerse
brewer in water.
2. Remove and empty decanters.
3. Remove and empty brew chamber.
IMPORTANT:
4. Remove the spray disk from the brew head (See figure 6):
Press up on the spray disk ears, then turn the disk to the left
to unlatch. Remove the gasket from inside the brew head.
DO NOT use steel wool, sharp
objects, or caustic, abrasive or
chlorinated cleansers to clean
the brewer.
5. Wipe inside of brew head and area around the brew head
with a soft clean cloth or sponge moistened with clean water.
6. Wash the spray disk in a sink using warm water and a mild
detergent. A bristle brush may be used to clear clogged
spray holes. Rinse the spray disk with clean water and allow
to air dry.
7. Wash the brew chamber in a sink using warm water and a
mild detergent. A bristle brush may be used to clean the
inside. Rinse with clean water and allow to air dry. For
stainless steel brew chambers, be sure the wire rack is
properly reinstalled.
8. Wipe the exterior of the brewer with a soft clean cloth or
sponge moistened with clean water.
10. Reinstall the gasket INSIDE the brew head, then reinstall the
spray disk.
11. Reinstall the brew chamber.
12. Remove stopper assembly from airpot:
a. Airpots may be washed by filling with warm soapy water
and cleaned with a bottle brush.
Fig. 6 Cleaning
IMPORTANT: DO NOT submerge airpots in water.
b. Stopper assembly may be washed in a sink with warm
soapy water.
c. Rinse airpot and stopper thoroughly with clean warm
water and allow to air dry .
Procedure is complete
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING INSTRUCTIONS (continued)
CAUTION:
Electric Shock
Hazard
PROCEDURE: Clean and Sanitize Basin Pan
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
Removing the top panel will
expose uninsulated circuits.
Unplug the brewer before
removing the top panel.
This procedure to be performed
by a qualified person only.
FREQUENCY:
TOOLS:
Monthly
#2 Phillips Head Screwdriver
Mild Detergent, Food Equipment Sanitizer
Clean Soft Cloth or Sponge
IMPORTANT:
1. Disconnect brewer from electric power.
Allow brewer to cool before cleaning.
DO NOT use steel wool, sharp
objects, or caustic, abrasive or
chlorinated cleansers to clean
2. Remove and empty decanters and brew chamber.
basin pan or cabinet panels.
3. Remove water bottle. Drain water from hot water faucet until
water no longer flows.
4. Remove four screws holding the top panel in place. Remove
the top panel. DO NOT remove the bottle ring from the top
panel.
5. Remove basin seal by working it out from under the flange at
the top of the brewer body.
6. Remove the silicone outlet elbow, overflow drain and vent
tube from basin pan. Remove the basin pan from the brewer.
7. Wash the basin pan and bottle ring with a clean cloth and
mild detergent.
7. Soak the basin pan, basin seal and top panel in sanitizer per
the directions supplied with the sanitizer.
8. Rinse the basin pan, basin seal and top panel with clean
water. Dry thoroughly with a clean cloth.
9. Reinstall the basin pan in brewer, making sure the vent tube,
overflow tube and outlet elbow are properly installed.
10. Reinstall basin seal, gasket side up, under the flange in the
top of the brewer body.
11. Reinstall the top panel. Install a water bottle in the bottle ring.
Drain water from the hot water faucet to purge air from the
system.
Fig. 7 Top Panel & Basin Pan
Procedure is complete
9
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING SUGGESTIONS
SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
Water won’t heat
Brewer unplugged or circuit
breaker tripped
Check power supply cord
Check / reset circuit breaker
Thermostat set too low
Set for desired temperature
Hi-Limit thermostat tripped
Allow to cool
Reset hi-limit (8786, 8788)
Damaged internal component or Examine wiring & connectors,
wiring
thermostat and heating element
Repair/replace as needed
Coffee level low
Water bottle empty
Replace water bottle
Adjust amount of grounds
Adjust timer
Too much coffee grounds
Timer out of adjustment
Coffee level too high or low
Brew chamber overflows
Too many filter papers or wrong Use one (1) genuine Bloomfield
filter paper
filter per brew
Brew chamber dispense hole
plugged
Thoroughly clean brew chamber
Too much coffee or too fine a
grind
Adjust coffee amount and grind
Sprays water from brew head
No brew
Spray gasket improperly
installed
Check/reinstall gasket on
INSIDE of brew head
Spray disk plugged
Brewer not plugged in
Water bottle empty
Bad BREW switch
Plug into electrical power
Clean spray disk
Replace water bottle
Replace switch
Damaged internal component or Examine wiring & connectors,
wiring
brew switch and solenoid
Repair/replace as needed
No flow from hot water faucet
Brewer overflows from basin
Poor coffee quality
Water bottle empty
Replace water bottle
Damaged water bottle
Water not hot enough
Install new water bottle
Adjust water temp 195-205ºF
Suggestions for consistently good coffee:
Keep brewer clean.
Use a quality coffee with a consistent roast.
Use proper grind and amount of coffee per brew.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INSTRUCTIONS
ACCESS PANELS
CAUTION
Electric Shock
Hazard
Top panel is held by four screws at the corners.
Front panel is held by two screws at the bottom and a retaining
lip at the top.
Opening access panels on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel
Fig. 8 Access Panels
NOTE:
TEMPERATURE ADJUSTMENT
Optimum brewing temperature
range is 195ºF to 205ºF (90ºC
to 96ºC).
With the “READY TO BREW” light ON, draw a cup of water from
the hot water faucet. Check the temperature of the water with a
thermometer of known accuracy.
IMPORTANT:
If temperature adjustment is necessary, remove water bottle and
top panel.
Adjust thermostat by turning shaft; clockwise increases
temperature. 1/8 turn = approximately 10ºF.
Refer to Table 1 below for proper brewing temperature based on
altitude.
A mechanical thermostat will
maintain temperature within
±10ºF. To prevent boiling water
in the brewer, thermostat should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 10ºF.
Upon completion, reinstall top panel.
BOILING
POINT OF
WATER
210
205
200
IDEAL
BREWING
TEMPERATURE
MAXIMUM SAFE
TEMPERATURE
SETTING
195
190
ELEVATION (feet above seal level)
Table 1 Boiling Temperature by Altitude
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INSTRUCTIONS (continued)
IMPORTANT: Adjust timer with
a full water bottle installed in the
bottle ring.
TIMER ADJUSTMENT
The amount of water dispensed automatically during a brew cycle
is controlled by the timer.
Place empty airpot under brew chamber. Press BREW button.
Brewer should dispense one airpot of water. To adjust amount:
Remove brew chamber and button plug. Adjust knob on timer;
clockwise increases time. Run several cycles to check amount of
water delivered. Replace button plug.
REMOVE TANK LID ASSEMBLY
IMPORTANT: Before setting
assembly into tank, make sure
tank lid gasket is properly
seated on flange of lid.
Unplug brewer or turn circuit breaker OFF. Remove water bottle.
Run water from the hot water faucet until no more water flows
Remove top panel. Siphon water from the tank through the
faucet supply fitting until the water level in the tank is below the
tank lid.
DO NOT OVER-TIGHTEN.
Pull vent tube and inlet elbow out of basin pan. Remove basin
pan.
Disconnect faucet supply from tank lid.
IMPORTANT: When removing
tank lid assembly, be careful to
not damage or kink thermostat
capillary tube.
Disconnect wires from thermostat. Remove screws holding
thermostat to bracket. Do not remove thermobulb from tank lid.
Disconnect all wiring from heating element. Slide hi-limit out of
the way.
Loosen center screw on tank hold-down bracket and loosen
acorn nuts. Remove hold-down bracket by sliding short slotted
end off of locking stud and lifting it off. Remove tank lid assembly
by lifting it straight up.
Reassemble in reverse order.
REPLACE THERMOSTAT
IMPORTANT: When mounting
thermostat, be sure a new seal
washer is placed below the
fitting on the capillary line.
Push sensing bulb thru tank lid
until fitting seats.
Tighten capillary lock nut only
enough to ensure no water
leakage. Excessive tightening
is not necessary.
Unplug brewer or turn circuit breaker OFF. Remove water bottle
and drain water from hot water faucet until no more water flows.
Remove top panel.
Disconnect all wiring from thermostat only. Loosen and free jam
nut from pass-thru fitting securing temperature sensing bulb.
Remove two screws holding thermostat to bracket.
Lift out thermostat, sensing bulb and thermostat gasket.
Reassemble in reverse order.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INSTRUCTIONS (continued)
REPLACE HEATING ELEMENT
IMPORTANT: When replacing
heating element, also replace
seal gaskets.
Remove tank lid assembly per above.
Remove two hex nuts holding element to cover. Pull element
from mounting holes.
Reassemble in reverse order.
REPLACE SOLENOID
Symptom: brewer will not flow water; or, brewer drips
continuously from brew head.)
Unplug power cord or turn circuit breaker OFF. Turn OFF and
disconnect water supply from brewer inlet fitting.
Remove water bottle and top panel.
Cut tie straps from solenoid hose connections. Remove wiring
connections from solenoid coil. Remove solenoid
Reassemble in reverse order.
REPLACE TIMER ASSEMBLY
Unplug power cord or turn circuit breaker OFF.
Remove front panel. Remove knob and three screws holding
timer to bracket. Disconnect wiring to timer.
Reassemble in reverse order.
Adjust timer as described on page 12.
REPLACE BREW READY LIGHT OR BREW SWITCH
Unplug power cord or turn circuit breaker OFF.
Remove water bottle, top panel and basin pan.
Using Switch Removal Tool (p/n 83209) or a thin screwdriver, pry
light or switch from mounting hole. Disconnect leads.
Reassemble in reverse order.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INSTRUCTIONS (continued)
CAUTION -
CHEMICAL BURN
HAZARD
PROCEDURE: Delime the Water Tank
PRECAUTIONS: Disconnect brewer from electric power.
Allow brewer to cool.
Deliming chemicals are caustic.
Wear appropriate protective
gloves and goggles during this
procedure.
Never siphon deliming
chemicals or solutions by
mouth.
FREQUENCY:
TOOLS:
As required (Brewer slow to heat)
Deliming Solution
Protective Gloves, Goggles & Apron
Mild Detergent, Clean Soft Cloth or Sponge
Bristle Brush, Bottle Brush
This operation should only be
performed by qualified and ex-
perienced service personnel.
Large Sink (or other appropriate work area)
1. Disconnect brewer from the electrical supply. Remove the
water bottle and drain the tank by running water from the hot
water faucet until no more water flows.
IMPORTANT: DO NOT spill,
splash or pour water or deliming
solution into or over any internal
component other than the inside
of the water tank.
2. Remove the tank lid assembly as described on page 12.
3. Remove the water tank from the brewer body by lifting
straight up. Empty all water from the tank. Set the tank back
into the brewer.
IMPORTANT: DO NOT allow
any electrical wiring or
components to come into
contact with the deliming
solution. Take care to keep all
electrical components and
wiring dry.
4. Mix 2 quarts of deliming solution according to the
manufacturer’s directions. Carefully pour the deliming
solution into the water tank. Lower the lid assembly back
onto the tank. Allow to sit for 30 minutes, or as directed by
the manufacturer.
5. At end of soaking period, remove lid assembly from tank.
Thoroughly rinse internal components of lid assembly with
clear water. Using a stiff bristle brush, scrub the heating
element to remove lime and calcium build-up. Rinse with
clean water. Store lid assembly in a safe location .
NOTE: Repeat steps 4 thru 5
as required to remove all scale
and lime build-up.
6. Remove the tank from the brewer and empty. Using a stiff
bristle brush, scrub the interior of the water tank to remove
lime and calcium build-up. Rinse with clean water.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INSTRUCTIONS (continued)
7. Set the tank back into the brewer. Reassemble the tank lid to
NOTE: Normally, silicone
hoses do not need to be
delimed. Should deliming
hoses become necessary,
Bloomfield recommends
replacing the hoses.
the water tank. Make sure the gasket is properly in place,
then reinstall the hold-down strap.
8. Reinstall wiring to heating element and thermostat. Reinstall
the hi-limit thermostat . Verify that all internal components
are dry, then reinstall the top panel.
10. Reconnect brewer to electrical supply.
11. Install the brew chamber without filter paper or grounds.
Run at least three full brew cycles and discard all water
generated.
12. Brewer is ready to use.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
EXPLODED VIEW & PARTS LIST
8382 PLUMBING COMPONENTS
ITEM
PART#
DESCRIPTION
QTY
8
13
25
29
30
33
34
34a
40
41
42
43
45
46
54
59
60
61
62
66
68
69
114
200
T
83538
TUBE, FAUCET SUPPLY 10” SILICONE
STRAP, TANK LID HOLD DOWN
ELBOW, BREW NOZZLE SILICONE
FAUCET
WASHER, FLAT SS 15/32 x 1-1/8 OD
GASKET, SPRAY DISK
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
8
8043-5
8043-13
8783-1
82681
8543-42
84132
8543-45
8810-70
83384
85609
82241
83388
85634
8043-12
86771
8043-15
8043-11
85624
8043-24
8043-10
83385
8760-3
8942-6B
SPRAY DISK
BREW HEAD (must be drilled & riveted to install)
RESTRICTOR, BREW NOZZLE
TUBE, FAUCET SUPPLY METAL
INSERT, BREW OUTLET ELBOW
FITTING, BARBED BRASS
SOLENOID, BREW 120V
TUBE, BREW SILICONE
GASKET, TANK LID
INLET & VENT TUBE ASSY
TUBE, VENT SILICONE
ELBOW, OUTLET SILICONE
TANK LID ASSEMBLY
TUBE, TANK WATER INLET METAL
TANK BODY
TUBE, OVERFLOW DRAIN SILICONE
BASIN PAN
BREW CHAMBER BLACK PLASTIC
CABLE TIE, PLASTIC
16
Download from Www.Somanuals.com. All Manuals Search And Download.
EXPLODED VIEW & PARTS LIST (continued)
ITEM PART#
DESCRIPTION
QTY
31
32
35
36
36t
37
45
50
56
63
67
8707-55
8718-31
8812-61
6407-15
8552-18
51217
83388
86280
8043-30
8043-83
8043-14
SWITCH, BREW MOMENTARY 120V
INDICATOR LIGHT, GREEN 120V
TIMER, 8 MIN
POWER CORD, NEMA 5-15P
TERMINAL BLOCK, 4P
STRAIN RELIEF 90º CLAMP
SOLENOID, BREW 120V
THERMOSTAT, 199ºF
1
1
1
1
1
1
1
1
2
1
1
SEAL, HEATING ELEMENT
THERMOSTAT, HI-LIMIT 120V
HEATING ELEMENT, 120V 1500W
17
Download from Www.Somanuals.com. All Manuals Search And Download.
EXPLODED VIEW & PARTS LIST (continued)
ITEM
PART#
DESCRIPTION
QTY
33
34
34a
70
71
72
8543-42
84132
8543-45
8706-75
GASKET, SPRAY DISK
SPRAY DISK
1
1
1
1
4
2
4
BREW HEAD (must be drilled & riveted to install
BUTTON PLUG, 2” DIA
END CAP, SUPPORT PLASTIC
SUPPORT, ALUMINUM BLACK ANODIZED
LEG ADJUSTABLE
73
81732
73a
73b
75
78
80
8033-55
8033-56
8543-69
8810-12
85583
LEG, METAL
FOOT, RUBBER
BUSHING, SHORTY HEYCO
BUTTON PLUG 7/8” DIA
BOTTLE RING (Model 8382)
BOTTLE RING, OASIS (Model 8382OR)
LABEL
2
2
1
1
1
80x
81
3300
85619
101
102
104
110
111
112
112x
113
113x
114
116
117
200
201
BASE, BODY ASSEMBLY
BASE, FRONT PANEL
BASE, DOOR
BASIN, BODY ASSEMBLY
BASIN, REAR PANEL
BASIN, TOP COVER(Model 8372)
BASIN, TOP COVER(Model 8372OR)
RETAINER, BOTTLE RING (Model 8372)
RETAINER, BOTTLE RING (Model 8372OR)
BASIN PAN
BASIN PAN SEAL GASKET
BASIN PAN SEAL
BREW CHAMBER BLACK PLASTIC
FILTER PAPER (case of 1000)
1
1
1
1
1
1
1
1
1
1
1
1
1
A/R
8760-3
8942-6B
POF
18
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAM
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Bloomfield Industries proudly supports CFESA
Commercial Food Equipment Service Association
Bloomfield Industries, Inc.
Division of Carrier Commercial Refrigeration
In US and Canada
Telephone: 775-689-5700
Fax:
Fax:
888-492-2783
800-356-5142 (for orders only)
PRINTED IN UNITED STATES OF AMERICA
Download from Www.Somanuals.com. All Manuals Search And Download.
|