Black Box TV Converter Box Industrial SFP SFP Multi Power Mode Converter User Manual

LGC300A-R2  
Industrial SFP/SFP Multi-Power Mode Converter  
Converts any fiber optics type interface  
to any other fiber optics type interface.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Certifications  
Certifications  
Class 1 Laser product, Luokan 1 Laserlaite,  
Laser Klasse 1, Appareil A’Laser de Classe  
European Directive 2002/96/EC (WEEE) requires that any equipment that  
bears this symbol on product or packaging must not be disposed of with  
unsorted municipal waste. This symbol indicates that the equipment should  
be disposed of separately from regular household waste. It is the  
consumer’s responsibility to dispose of this and all equipment so marked  
through designated collection facilities appointed by government or local  
authorities. Following these steps through proper disposal and recycling will  
help prevent potential negative consequences to the environment and  
human health. For more detailed information about proper disposal, please  
contact local authorities, waste disposal services, or the point of purchase for  
this equipment.  
LGC300A-R2  
724-746-5500 | blackbox.com  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Table of Contents  
Part Numbers ......................................................................................................5  
1.  
1.1  
2.  
Specifications .........................................................................................6  
Standards/Compliance...........................................................................6  
Overview: About the Industrial SFP/SFP Multi-Power Mode  
Converter................................................................................................7  
2.1  
3.  
Features .................................................................................................7  
Install the Industrial SFP/SFP Multi-Power Mode Converter .................8  
SFP Port Requirements .........................................................................8  
DIN Rail Mounting ..................................................................................8  
Powering the Industrial SFP/SFP Multi-Power Mode Converter ...........8  
DC Terminal Block Option.............................................................9  
Cascading DC Power ....................................................................9  
DC Power Supply Precautions.............................................................10  
Operation..............................................................................................11  
LED Operation......................................................................................11  
Contacting Black Box ...........................................................................12  
Fiber Optic Cleaning Guidelines ..........................................................13  
Electrostatic Discharge Precautions ....................................................14  
3.1  
3.2  
3.3  
3.3.1  
3.3.2  
3.4  
4.  
4.1  
5.  
6.  
7.  
Page 4  
724-746-5500 | blackbox.com  
LGC300A-R2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Part Numbers  
Part Numbers  
Part Number  
Description  
LGC300A-R2  
MultiPower SFP to SFP Mode Converter (SFPs sold  
separately)  
LGC300A-R2  
724-746-5500 | blackbox.com  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1: Specifications  
1. Specifications  
DC Input  
+7 VDC to +50 VDC @ 2.5 watts. Actual current  
consumption may vary depending on the type of  
SFP modules installed. When not using the  
supplied AC/DC converter the externally supplied  
DC power must be provided from a LPS source.  
AC Wall Adapter  
100 to 240 ±10% VAC input, 5 VDC output @ 2A  
max.  
Operating  
-13°F to +185°F (-25°C to +85°C) DC configuration  
Temperature  
+14°F to +122°F (-10°C to +50°C) with Franmar AC wall  
adapter  
Storage Temperature -49°F to 185° F (-45°C to 85° C)  
Shipping Weight  
Dimensions  
0.25 lbs (0.11 kg)  
0.83” H x 1.80” W x 3.35” D (2.11 x 4.57 x 8.51 cm)  
1.1 Standards/Compliance  
SFP-MSA SFP standard (September 14, 2000)  
SFF-8472 DDMI standard (Revision 1.0)  
All SFPs used in this product should be certified to IEF 60825-1.  
Page 6  
724-746-5500 | blackbox.com  
LGC300A-R2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2: Overview  
2. Overview: About the Industrial SFP/SFP Multi-Power Mode  
Converter  
The Industrial SFP/SFP is a pure mode converter that converts any fiber  
optics type to any other fiber optics type. This product is a Protocol  
independent converter and is not intended for applications that require  
retiming or any Layer 2 functions. The Industrial SFP/SFP supports  
extended temperature operation.  
The Industrial SFP/SFP requires two small form-factor (SFP) modules (sold  
separately), which provide greater fiber flexibility in the network environment.  
The hot-swappable nature of the SFPs and the numerous fiber modes and  
types available in SFPs allow for easy configuration and future upgrading as  
network demands evolve. The SFP modules must be MSA compliant and  
support the same speed range.  
The Industrial SFP/SFP operates as a mode converter only and not as a rate  
converter.  
The Industrial SFP/SFP does not provide support for copper (TX) SFPs.  
2.1 Features  
The Industrial SFP/SFP provides the ability to change optical transport  
characteristics using easy-to-install SFP devices. This mix-and-match  
functionality is only limited by the available Black Box SFP units. For more  
The key features of the Industrial SFP/SFP are:  
Uses Miniature Media Converter Form Factor  
Supports a 7 VDC to 50 VDC terminal block option with cascading power  
Supports an external 5 VDC power option (not extended temperature)  
Allows extended temperature range from -13°F to 185° F (25°C to 85°C)  
Uses all standard MSA-complaint SFP devices (excluding copper SFPs)  
Provides extensive diagnostic LED functions  
Supports DIN Rail mounting  
LGC300A-R2  
724-746-5500 | blackbox.com  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Install the Industrial SFP/SFP Multi-Power Mode Converter  
3. Install the Industrial SFP/SFP Multi-Power Mode Converter  
The Industrial SFP/SFP Multi-Power Mode Converter installs anywhere as a  
standalone, table-top device or on a DIN rail.  
As a standalone device, install it in locations with limited space.  
If multiple connections are required, use an IE-PowerTray/18 enclosure (sold  
separately). The tray allows for 18 conversions in a 1.5 rack unit of space.  
The units can also be powered by daisy-chaining DC power (refer to  
Cascading DC Power).  
3.1 SFP Port Requirements  
The Industrial SFP/SFP Multi-Power Mode Converter requires two SFP  
Modules of the same speed, either two Fast Ethernet (100Mbps) modules or  
two Gigabit Ethernet (1000Mbps) modules.  
3.2 DIN Rail Mounting  
The Industrial SFP/SFP Multi-Power Mode  
Converter includes two DIN clips, allowing  
installation on a DIN rail. It mounts  
perpendicular to the DIN rail (as shown).  
Use the supplied screws to attach the DIN  
clips to the Industrial SFP/SFP, and then  
snap the converter to the DIN rail.  
To remove the converter from the DIN rail,  
use a flat-head screwdriver in the slot to  
gently pry the converter from the rail.  
NOTE  
The DIN clips are designed for use on a DIN-35 rail.  
3.3 Powering the Industrial SFP/SFP Multi-Power Mode Converter  
The Industrial SFP/SFP Multi-Power Mode Converter requires an external  
DC power source and has three options for powering as options:  
Universal AC power adapter with country specific clip (not included with  
module version).  
Page 8  
724-746-5500 | blackbox.com  
LGC300A-R2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Install the Industrial SFP/SFP Multi-Power Mode Converter  
User supplied LPS DC power via a four-position DC power block.  
Power from an Power Tray 18-Slot DC  
For extended temperature operation the DC terminal block must be used  
because the supplied AC to DC converter is not rated for extended  
temperature operation. The power source used with the DC terminal block  
should be a Limited Power Source (LPS).  
3.3.1 DC Terminal Block Option  
The Industrial SFP/SFP DC power option includes a 7 VDC to 50 VDC  
terminal block and a standard +5 VDC mini-jack. The DC terminal block has  
multiple DC inputs intended for cascading DC power to an adjacent unit.  
Connect the power source to any one positive and one negative terminal on  
the Industrial SFP/SFP.  
NOTE  
When using stranded wire, the leads must be tinned. The chassis is not protected  
against mis-wiring; if mis-wired the chassis will not function. The chassis is internally  
connected to the negative power terminal.  
3.3.2 Cascading DC Power  
If installing multiple Industrial SFP/SFPs on a  
DIN rail, you can use one DC input source  
and then cascade from one DC terminal  
block to the next, until reaching the  
maximum electrical current available.  
LGC300A-R2  
724-746-5500 | blackbox.com  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3: Install the Industrial SFP/SFP Multi-Power Mode Converter  
3.4 DC Power Supply Precautions  
The following precautions must be observed when installing the chassis  
model with an internal DC power supply.  
1. Check nameplate ratings to ensure there is no overloading of supply  
circuits that could effect overcurrent protection and supply wiring.  
2. In addition, the following must be observed:  
a. Connect the equipment to a 35 to 50 VDC power source that is  
electrically isolated from the alternating current source. The 35 to 50  
VDC power source is connected to a SELV DC source.  
b. Route input wiring to terminal block and secure in such a manner  
that it is protected from damage and stress. Do not route wiring past  
sharp edges or moving parts.  
c. Incorporate a readily accessible disconnect device, with a 3mm  
minimum contact gap in the fixed wiring.  
3. Reliable Grounding of this equipment must be maintained. Particular  
attention should be given to supply connections when connecting to  
power strips, rather than direct connections to the branch circuit.  
Page 10  
724-746-5500 | blackbox.com  
LGC300A-R2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4: Operation  
4. Operation  
4.1 LED Operation  
The Industrial SFP/SFP contains four  
status LED indicators. Each LED is  
dual color and has three states: off, red,  
or green. A loss of signal on one SFP  
causes the TX of the other SFP to turn  
off. This action does not activate the  
red TX Fault LED.  
LED  
Color or State  
Red  
OFF  
Green  
Power is applied to the  
card.  
Card does not pass  
the self-test.  
Unit does not  
have power.  
PWR  
All internal self-test  
functions must pass  
before the PWR LED is  
green.  
SD I  
SD 2  
Valid signal is detected  
by the SFP and LED  
transmitter is not in  
fault.  
LED transmitter has  
an active fault.  
No active fault  
on transmitter.  
LOS indication  
on receiver.  
MSA  
LEDs  
One or both SFPs  
are not installed or  
not detected. The  
TX inhibit must not  
be active if a SFP is  
missing.* Or, both  
SFPs are installed,  
but their speed  
settings are  
N/A  
Indicates that both  
SFPs with the same  
speed are securely  
installed.  
different. This  
condition disables  
both SFPs.  
* To help in troubleshooting, the Link Loss (LL) feature is always ON. That is, if a  
LOS is detected on an incoming SFP port, the Optical transmitter on the other SFP  
port is turned OFF. This provides a Link Loss carry forward function to alert the  
device downstream of the existing problem. This function is "ON" in both directions  
at the same time. The LL function is inhibited if either SFP is not installed.  
LGC300A-R2  
724-746-5500 | blackbox.com  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5: Contacting Black Box  
5. Contacting Black Box  
Black Box Customer Service  
Order toll-free in the U.S.: Call 877-877-BBOX  
(outside U.S. call 724-746-5500)  
Free technical support, 24 hours a day, 7 days a week.  
Call: 724-746-5500 or Fax: 724-746-0746  
Mail order: Black Box Corporation  
1000 Park Drive, Lawrence, PA 15055-1018  
WARNING  
Disconnect all power supplies before servicing.  
Page 12  
724-746-5500 | blackbox.com  
LGC300A-R2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6: Fiber Optic Cleaning Guidelines  
6. Fiber Optic Cleaning Guidelines  
Fiber Optic transmitters and receivers are extremely susceptible to  
contamination by particles of dirt or dust, which can obstruct the optic path  
and cause performance degradation. Good system performance requires  
clean optics and connector ferrules.  
1. Use fiber patch cords (or connectors, if you terminate your own fiber) only  
from a reputable supplier; low-quality components can cause many hard-to-  
diagnose problems in an installation.  
2. Dust caps are installed at Black Box to ensure factory-clean optical devices.  
These protective caps should not be removed until the moment of connecting  
the fiber cable to the device. If you need to disconnect the fiber device,  
reinstall the protective dust caps.  
3. Store spare caps in a dust-free environment such as a sealed plastic bag or  
box so that when reinstalled they do not introduce any contamination to the  
optics.  
4. If you suspect that the optics have been contaminated, alternate between  
blasting with clean, dry, compressed air and flushing with methanol to remove  
particles of dirt.  
LGC300A-R2  
724-746-5500 | blackbox.com  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7: Electrostatic Discharge Precautions  
7. Electrostatic Discharge Precautions  
Electrostatic discharge (ESD) can cause damage to any product, add-in  
modules or stand alone units, containing electronic components. Always  
observe the following precautions when installing or handling these kinds of  
products.  
1. Do not remove unit from its protective packaging until ready to install.  
2. Wear an ESD wrist grounding strap before handling any module or  
component. If the wrist strap is not available, maintain grounded contact with  
the system unit throughout any procedure requiring ESD protection.  
3. Hold the units by the edges; do not touch the electronic components or gold  
connectors.  
4. After removal, always place the boards on a grounded, static-free surface,  
ESD pad or in a proper ESD bag. Do not slide the modules or stand alone  
units over any surface.  
WARNING! Integrated circuits and fiber optic components  
are extremely susceptible to electrostatic discharge damage.  
Do not handle these components directly unless you are a  
qualified service technician and use tools and techniques that  
conform to accepted industry practices.  
Page 14  
724-746-5500 | blackbox.com  
LGC300A-R2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
LGC300A-R2  
724-746-5500 | blackbox.com  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LGC300A-R2 Rev. 1  
55-80619BB-00 Rev. B1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Bissell Vacuum Cleaner 81L2 User Manual
Black Decker Automobile Accessories 187895 01 User Manual
Bloomfield Coffeemaker 8852D User Manual
Bonavita Coffeemaker BV1800TH User Manual
Brocade Communications Systems Computer Hardware 4016 User Manual
Brother Typewriter ML 300 User Manual
Canon Digital Camera WM V1 User Manual
Carrier Furnace 58EJA User Manual
Char Broil Gas Grill 4638220 User Manual
Chauvet Power Supply CH 202B User Manual