Express Ethernet Switch: LB9017A-R3  
15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.  
16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.  
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de  
ventilación.  
18. Servicio por personal calificado deberá ser provisto cuando:  
A: El cable de poder o el contacto ha sido dañado; u  
B: Objectos han caído o líquido ha sido derramado dentro del aparato; o  
C: El aparato ha sido expuesto a la lluvia; o  
D: El aparato parece no operar normalmente o muestra un cambio en su desempeño ; o  
E: El aparato ha sido tirado o su cubierta ha sido dañada.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
About This Manual  
Preface  
This manual describes how to install and use the 16 Ports Web-based Smart Ethernet Switch. The TX ports of the  
switch introduced here auto-negotiates the presence of 10/100Mbps and full/half-duplex mode and auto-MDIX. In  
addition, it allows an optional 100BaseFX multi-mode or single-mode fiber module, enabling long distance  
connection.  
To get the most out of this manual, you should have an understanding of networking concepts such as bridging,  
IEEE 802.3 10BaseT Ethernet, IEEE 802.3u 100BaseTX/FX Fast Ethernet, and local area networks (LANs).  
For more information about these topics, please refer to the Appendices.  
In this manual, you will find:  
Introduction on the Switch  
Product features  
Illustrative LEDs functions  
Installation instructions  
Specifications  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Table of Contents  
About This Manual......................................................................................................................................................3  
Preface ..........................................................................................................................................................................3  
Table of Contents.........................................................................................................................................................4  
Product Overview........................................................................................................................................................5  
Front View.................................................................................................................................................................5  
Figure 1: 16 Ports Web-based Smart Ethernet Switch ............................................................................................5  
Package Contents.......................................................................................................................................................5  
Product Features ........................................................................................................................................................6  
Front Panel Display ...................................................................................................................................................7  
Figure 3: Front Panel LEDs........................................................................................................................................7  
Physical Ports ............................................................................................................................................................7  
Understanding Front Panel Design........................................................................................................................7  
Installation....................................................................................................................................................................8  
Selecting a Site for the Equipment ............................................................................................................................8  
Installation and Placement Instructions.....................................................................................................................9  
Mounted to 19-inch standard rack .........................................................................................................................9  
Desktop or any flat surface....................................................................................................................................9  
Optional Fiber Module Installation..........................................................................................................................10  
Figure 4: Removal of cover plate  
Fiber module being installed ....................................................10  
Connecting to Power ...............................................................................................................................................11  
Figure 5: Rear view of the switch.............................................................................................................................11  
Connecting to Your Network...................................................................................................................................11  
Cabling ................................................................................................................................................................11  
Network Segmentation ........................................................................................................................................12  
Cable Specifications Table........................................................................................................................................12  
Switch Configuration ................................................................................................................................................13  
Setting up Console Port Connection (Web-Based Browser Interface) ....................................................................13  
Logging on to The Ethernet Switch.........................................................................................................................13  
Switch IP Address ...............................................................................................................................................13  
User Name...........................................................................................................................................................13  
Password..............................................................................................................................................................13  
Main Menu ..............................................................................................................................................................14  
System Change ....................................................................................................................................................14  
IP Configuration ..................................................................................................................................................15  
Port ......................................................................................................................................................................16  
VLAN..................................................................................................................................................................17  
Trunking ..............................................................................................................................................................18  
Save Configuration..............................................................................................................................................19  
Load Default........................................................................................................................................................20  
Technical Specifications............................................................................................................................................20  
Physical Specifications ..............................................................................................................................................21  
Connector Pinouts .....................................................................................................................................................22  
Figure 6: RJ-45 Connector and Cable Pins.............................................................................................................22  
Connector Pin-Out ....................................................................................................................................................22  
Ordering Information ...............................................................................................................................................23  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Product Overview  
Front View  
Figure 1: 16 Ports Web-based Smart Ethernet Switch  
Package Contents  
When you unpack the product package, you shall find these items listed below.  
3 The 16 Ports Switch  
3
One AC power cord  
3 User’s Manual  
Please inspect the contents, and report any apparent damage or missing items immediately to your authorized  
reseller.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Product Features  
PROVIDES 16 × 10/100MBPS PORTS USING RJ-45 CONNECTORS  
AN OPTIONAL SINGLE-PORT FIBER MODULE ALLOWS:  
- 100BASEFX MULTI-MODE FIBER WITH SC, ST, MT-RJ, VF-45 OR LC CONNECTOR  
- 100BASEFX SINGLE-MODE FIBER WITH SC CONNECTOR  
AUTO-NEGOTIATION FOR SPEED AND DUPLEX MODE ON TX PORTS  
16 PORTS: 2K MAC ADDRESSES, 2M BITS BUFFER MEMORY  
AUTO-MDIX FOR ALL TX PORTS  
STORE-AND-FORWARD MECHANISM  
TRUE NON-BLOCKING ARCHITECTURE  
FULL WIRE SPEED FORWARDING RATE  
BROADCAST STORM FILTERING CONTROL  
BACK-PRESSURE AND IEEE 802.3X COMPLIANT FLOW CONTROL  
SYSTEM, IP CONFIGURATION, PORT, PORT-BASED VLAN, AND PORT-BASED TRUNKING  
SETTING THROUGH THE WEB-BASED CONSOLE PORT.  
FRONT PANEL PUSH BUTTON TO CHOOSE 100BASEFX OR PORT 16  
PRESS THE FRONT PANEL IP RESET PUSH BUTTON FOR FIVE SECONDS TO RESET THE  
ETHERNET SWITCH BACK TO THE DEFAULT IP ADDRESS. ( THE PORT, VLAN, AND  
TRUNKING SETTINGS WILL REMAIN THE SAME AS WHEN THEY WERE LAST SAVED ).  
FRONT PANEL PORT AND POWER STATUS LEDS  
STANDARD 19” RACKMOUNT SIZE, ONE-UNIT IN HEIGHT  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Front Panel Display  
The LED indicators on the front panel provide you with instant feedback on each port status, and help you monitor  
and troubleshoot the switch.  
Figure 3: Front Panel LEDs  
Power  
This LED comes on when the switch is properly connected to power and turned on.  
Push Button  
The push button is located at the right side of port 16 on the 16-Port Switch.  
Depress this button to use twisted pair port 16, and press this button to use the 100BaseFX module.  
IP RESET Push Button  
Press the Front panel IP RESET push button around five seconds to reset the Ethernet Switch back with  
the default IP Address.  
Port Status  
The RJ-45 ports are numbered from 1 to 16 on the 16-Port Switch.  
The LEDs are located on the ports of the switch, displaying status for each respective port. Please refer  
to the table below for more information.  
Consult the following table for details.  
L
Before you use this table for troubleshooting, make sure the switch is properly connected to power and turned on.  
Physical Ports  
The 16 Ports Switch has sixteen or twenty-four 10/100Mbps ports using RJ-45 connectors and provides one slot for  
the optional single-port fiber module. The optional module allows fiber type (multi-mode or single-mode fiber) and  
connector (SC, ST, MT-RJ, VF-45, or LC) at user’s discretion.  
Understanding Front Panel Design  
Power feeding in  
Power LED  
On  
Off  
Power switched off  
Improper connection  
Console LNK  
Port LED  
On  
Off  
A valid network connection  
LNK stands for LINK  
No connection  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
ACT  
Flashing Transmitting or receiving  
data  
ACT stands for ACTIVITY  
Off  
Port LED LNK/ACT On  
Neither  
receiving data  
transmitting  
nor  
A valid network connection  
LNK stands for LINK  
Flashing Transmitting or receiving  
data  
ACT stands for ACTIVITY  
Off  
Neither  
activity  
connection  
nor  
SPEED  
LNK  
On  
Off  
On  
A valid 100Mbps connection  
A valid 10Mbps connection  
100FX  
Port  
A valid network connection  
LNK stands for LINK  
LED  
Off  
No connection  
ACT  
Flashing Transmitting or receiving  
data  
ACT stands for ACTIVITY  
Off  
Neither  
receiving data  
transmitting  
nor  
Installation  
Selecting a Site for the Equipment  
As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures,  
humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:  
-
-
-
The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 50 degrees Celsius).  
The relative humidity should be less than 90 percent, non-condensing.  
Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M)  
field strength.  
-
-
Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes on each side of the switch or  
on the rear of the equipment.  
The power outlet should be within 6 feet ( 1.8 meters ) of the switch.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Installation and Placement Instructions  
Mounted to 19-inch standard rack  
Locate the accessories supplied in the product package. Use the rackmount brackets and screws to install the switch  
into any EIA 19” standard rack.  
Step 1: Attach the brackets to each side of the chassis.  
Step 2: Apply the screws to each side and secure them tightly.  
Step 3: Carefully position the switch into the rack.  
Step 4: Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack.  
Step 5: Proceed to the “Connecting to Power” section.  
Desktop or any flat surface  
The switch can sit on desktop or any flat surface with adequate space and ventilation. If you want to place it onto a  
shelf, make sure the shelf can withstand the weight of the switch.  
Step 1: Simply put the switch on the desired place.  
Step 2: Ensure the switch receives good ventilation.  
Step 3: Proceed to the “Connecting to Power” section.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Optional Fiber Module Installation  
Consult the following illustrations before installation.  
Step 1: Make sure the power is switched off. The module is not hot-swappable.  
L
It may cause electric shock or any possible damage to the switch if the power is not switched off.  
Step 2: Remove the module from the static-free container.  
Step 3: Unscrew the cover plate of the expansion slot.  
(The slot for single-port module is located at the right side of the switch.)  
Step 4: Remove the plate.  
(Keep it for future use if you decide to remove this module later.)  
Step 5: Carefully slide the module into the slot, following the internal plastic guide rails.  
Step 6: Once it is fully slid in, snap in the module to make a proper connection.  
Step 7: Fasten the module screws.  
Step 8: Finally, turn on the power.  
Figure 4: Removal of cover plate  
Fiber module being installed  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Connecting to Power  
Locate the supplied AC power cord.  
Step 1:Connect the AC power cord to the receptacle at the back of the switch.  
Step 2:Attach the plug into a standard AC outlet with a voltage range from 100~240Vac.  
Step 3: The power LED on the front panel will then illuminate.  
Figure 5: Rear view of the switch  
Connecting to Your Network  
Cabling  
Step 1: First, ensure the power of the switch (and end devices) is turned off.  
LIt may cause an electric shock or any possible harm to you if the power is not switched off.  
Step 2: Prepare cable with corresponding connectors for each type of port in use.  
(Consult the table below for cabling requirements based on connectors and speed considerations. )  
Step 3: Connect one end of the cable to the switch and the other end to a desired device.  
Step 4: Once the connections between two end devices are made successfully, turn on the power and the switch is operational.  
User’s Manual  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Network Segmentation  
The maximum segment distance between a node and a directly connected switch port on a 100BaseFX network is  
75km using 10/125 (or 9/125)µm single-mode fiber optic cable. It is capable of a maximum span of 2km when  
62.5/125 (or 50/125)µm multi-mode fiber optic cable is used.  
Cable Specifications Table  
Ethernet  
Connector  
Port  
Cable  
Max.  
Standards  
Speed  
Half/Ful  
l Duplex  
Distanc  
e
10BaseT  
RJ-45  
RJ-45  
10/20  
Mbps  
Cat. 3, 4 or 5 100 m  
UTP/STP  
100BaseTX  
100/200  
Mbps  
Cat.  
5
100 m  
UTP/STP  
µ
µ
100BaseFX  
ST, SC, MT- 100/200  
RJ, VF-45, Mbps  
LC  
62.5/125  
multi-mode  
fiber  
m
2 km  
Multi-mode  
100BaseFX  
SC  
SC  
SC  
100/200  
Mbps  
10/125  
m
m
m
15 km  
40 km  
75 km  
single-mode  
fiber  
Single-mode  
µ
100BaseFX  
100/200  
Mbps  
10/125  
single-mode  
fiber  
Single-mode  
µ
100BaseFX  
100/200  
Mbps  
10/125  
single-mode  
fiber  
Single-mode  
User’s Manual  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Switch Configuration  
Setting up Console Port Connection (Web-Based Browser Interface)  
The Ethernet Switch provides a browser interface that lets you configure and manage the  
Ethernet Switch from a Web browser (such as Microsoft Internet Explorer or Netscape  
Navigator) remotely.  
By connecting to the Ethernet Switch’s console port, you can access the Ethernet Switch’s web  
interface applications directly in your web browser by entering the default IP address of the  
Ethernet Switch (192.168.1.10). You can then use your web browser to list and manage the  
Ethernet Switch configuration parameters from one central location.  
Logging on to The Ethernet Switch  
Switch IP Address  
In your web browser, specify the default IP address of the Ethernet Switch (192.168.1.10 ).  
Example: ( 1616W: 192.168.1.8 )  
User Name  
Enter the factory default user name: admin.  
Password  
Enter the factory default password (no password, press Enter directly).  
Otherwise, enter a user-defined password if you followed the instructions later and changed the  
factory default password.  
User’s Manual  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Main Menu  
System Change  
The System Change parameters can be displayed by clicking the System Change button in the  
left sub-menu.  
z
Switch Name: Type a switch name and replace the current switch name with a new one. (  
Please restart your Computer once the Switch Name is replaced and saved under “ Save  
Configuration “ by the new name ).  
<Note> ( Only “ a-z “, “A-Z”, “0-9”, “under line” & “Space” can be acceptable, totally can  
not exceed 16 characters ).  
User’s Manual  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
z
z
Password: Enter a user-defined password and change the factory default password.  
<Note> ( Only “ a-z “, “A-Z”, “0-9”, “under line” & “Space” can be acceptable, totally can  
not exceed 16 characters ).  
Apply: Click the Apply button and apply the new System settings.  
IP Configuration  
z
z
Refresh: Click the Refresh button and refresh back to the last saved IP Configurations.  
IP Address, Netmask, Default Gateway: You can see and change the IP Address, Netmask,  
and Default Gateway of the Ethernet Switch.  
z
Apply: Click the Apply button and apply the new IP Configurations.  
User’s Manual  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Port  
z
Refresh: Click the Refresh On or Refresh Off button to or not to refresh back to the last  
saved settings of the ports.  
<Note> It is recommended to change the Refresh On button to Refresh Off while you  
change the settings of the ports. The Refresh On will refresh the settings of the ports  
shown on the screen around every ten seconds.  
z
z
z
z
Mode: Choose AUTO, 10HD, 10FD, 100HD or 100FD for the ports.  
Flow Control: Choose Enable or Disable to enable or disable the flow control of the ports.  
Transmit / Receive: Choose On or Off to turn on or off transmit / receive of the ports.  
Apply: Click the Apply button and apply the new settings of the ports.  
User’s Manual  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
VLAN  
z
z
VLAN: Click and choose the ports to be added into the VLAN groups.  
Apply: Click the Apply button and apply the new settings of the VLAN groups.  
<Note> All Ports have to be selected to one of the VLAN Groups, those Port/Ports were not  
selected will be notified by the alarm message which shows “ Non-Identify VLAN Group  
On Port “.  
User’s Manual  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Trunking  
16 Ports Ethernet Switch:  
z
Disable: Click and choose the Disable to disable the Trunking Group 1 or Trunking Group  
2.  
z
z
z
Trunking Group 1: Click and choose the Port 1, 2 to be added into the Trunking Group 1.  
Trunking Group 2: Click and choose the Port 9, 10 to be added into the Trunking Group 2.  
Apply: Click the Apply button and apply the new settings of the Trunking Groups.  
User’s Manual  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Save Configuration  
z
z
Click Save Configuration.  
Click the Ok or Cancel button to or not to save the configurations.  
<Note> The Cancel button will discard any data you have changed since the last "Save"  
operation. Without clicking Ok button, the switch does not save any changes you may  
have made.  
User’s Manual  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Load Default  
z
z
Click Load Default.  
Click the Ok or Cancel button to or not to load the default settings.  
< Note > Once the Ok button is selected, all last saved Port, VLAN, and Trunking  
setting will revert back to the default settings.  
Technical Specifications  
16 Ports Web-based Smart Ethernet  
Switch  
Applicable  
Standards  
IEEE 802.3 10BaseT  
IEEE 802.3u 100BaseTX/FX  
Fixed Ports  
Sixteen ports for the 16-Port Switch  
100BaseFX multi-mode or single-mode module  
Optional 1-port  
Module Type  
Speed  
100BaseTX/FX:  
200Mbps for full-duplex; 100Mbps for half-duplex  
10BaseT:  
20Mbps for full-duplex; 10Mbps for half-duplex  
Store-and-Forward  
Switching  
Method  
Performance  
148,800pps forwarding rate per port for 100Mbps  
14,880pps forwarding rate per port for 10Mbps  
Chassis  
Power LED  
LED Indicators  
For Console Port:  
LNK; ACT (2 LEDs)  
For ports:  
LNK/ACT; SPEED (2 LEDs)  
User’s Manual  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Physical Specifications  
16 Ports Web-based Smart Ethernet  
Switch  
Dimensions  
17.3 x 8.2 x 1.74 in. ( W440 × D207 × H44 mm )  
19” rack mount size, 1U high  
Weight  
Approximately 6.2 pounds ( 2.8kg )  
Power Input  
100 ~ 240 VAC, 50~60 Hz  
Input Fuse  
Power  
16 Ports: 3.3Volts DC, 4A  
16 Ports: 15W Maximum  
Operating  
32° ~ 122°F ( 0° ~ 50°C )  
Temperature  
Storage  
-13° ~ 158°F ( -25° ~ 70°C )  
Temperature  
Humidity  
Emissions  
10 ~ 90%, non-condensing  
FCC part 15 Class A, CE Mark  
User’s Manual  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch: LB9017A-R3  
Connector Pinouts  
Pin arrangement of RJ-45 connectors:  
Figure 6: RJ-45 Connector and Cable Pins  
The following table lists the pinout of 10/100BaseT/TX ports.  
Connector Pin-Out  
Pin Regular Ports  
Uplink port  
1
2
3
4
5
6
7
8
Input Receive Data +  
Input Receive Data -  
Output Transmit Data +  
NC  
Output Transmit Data +  
Output Transmit Data -  
Input Receive Data +  
NC  
NC  
NC  
Output Transmit Data -  
NC  
NC  
Input Receive Data -  
NC  
NC  
User’s Manual  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Express Ethernet Switch  
Ordering Information  
16 Fixed Ports  
Single-Port Module  
Cable  
Connector  
Cable (/125µm)  
Connector  
MMF  
(50µm or 62.5µm)  
Distance  
Speed  
Distance  
2km  
3
100BaseTX:  
100m  
100BaseFX  
Cat. 5 or better  
UTP/STP  
SC  
MMF  
(50µm or 62.5µm)  
ST  
MMF  
(50µm or 62.5µm)  
MT-RJ  
MMF  
(50µm or 62.5µm)  
VF-45  
MMF  
(50µm or 62.5µm)  
LC  
2km  
100BaseFX  
100BaseFX  
100BaseFX  
100BaseFX  
100BaseFX  
100BaseFX  
100BaseFX  
RJ-45  
2km  
OR  
2km  
10BaseT:  
Cat. 3, 4, 5 or  
better UTP/STP  
2km  
RJ-45  
SMF  
(9µm or 10µm)  
15km  
40km  
75km  
SC  
SMF  
(9µm or 10µm)  
SC  
SMF  
(9µm or 10µm)  
SC  
L
i.  
The maximum node-to-node network distance is in full-duplex operation.  
MMF denotes Multi-Mode Fiber. SMF denotes Single-Mode Fiber.  
ii.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  

BenQ Network Card AWL 100 User Manual
Bertazzoni Cooktop P61 P61V User Manual
Black Decker Iron AS700 User Manual
Blockhead Video Game Controller BH4008 User Manual
Bose Webcam CE 1 User Manual
Bravetti Electric Grill EP865 User Manual
Brother Laptop WP 2200 User Manual
Carrier Furnace 58EFA User Manual
Casio Musical Instrument WK 3300 User Manual
Century Stroller PM 1026AB User Manual