SEPTEMBER 2001
IC266A
USB Single-Port Hub
(RS-422/485)
CUSTOMER SUPPORT INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com
•
E-mail: [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
NORMAS OFICIALES MEXICANAS (NOM)
ELECTRICAL SAFETY STATEMENT
INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes
de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para
referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de
operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo,
cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca,
etc..
6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales
que sean recomendados por el fabricante.
7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea
recomendado por el fabricante.
8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más
allá a lo descrito en las instrucciones de operación. Todo otro servicio
deberá ser referido a personal de servicio calificado.
9. El aparato eléctrico debe ser situado de tal manera que su posición no
interfiera su uso. La colocación del aparato eléctrico sobre una cama,
sofá, alfombra o superficie similar puede bloquea la ventilación, no se
debe colocar en libreros o gabinetes que impidan el flujo de aire por los
orificios de ventilación.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
NOM STATEMENT
10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor
como radiadores, registros de calor, estufas u otros aparatos (incluyendo
amplificadores) que producen calor.
11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del
tipo descrito en el instructivo de operación, o como se indique en el
aparato.
12. Precaución debe ser tomada de tal manera que la tierra fisica y la
polarización del equipo no sea eliminada.
13. Los cables de la fuente de poder deben ser guiados de tal manera que no
sean pisados ni pellizcados por objetos colocados sobre o contra ellos,
poniendo particular atención a los contactos y receptáculos donde salen
del aparato.
14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las
recomendaciones del fabricante.
15. En caso de existir, una antena externa deberá ser localizada lejos de las
lineas de energia.
16. El cable de corriente deberá ser desconectado del cuando el equipo no
sea usado por un largo periodo de tiempo.
17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean
derramados sobre la cubierta u orificios de ventilación.
18. Servicio por personal calificado deberá ser provisto cuando:
A: El cable de poder o el contacto ha sido dañado; u
B: Objectos han caído o líquido ha sido derramado dentro del
aparato; o
C: El aparato ha sido expuesto a la lluvia; o
D: El aparato parece no operar normalmente o muestra un cambio en
su desempeño; o
E: El aparato ha sido tirado o su cubierta ha sido dañada.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
TRADEMARKS USED IN THIS MANUAL
®
UL is a registered trademark of Underwriters
Laboratories Incorporated.
®
Windows is a registered trademark of Microsoft
Corporation.
Any other trademarks mentioned in this manual are
acknowledged to be the property of the trademark owners.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
Contents
Chapter
Page
1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.2 Connector Pin Assignments (DB25 Male) . . . 7
2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.2 What the Package Includes . . . . . . . . . . . . . . . 8
2.3 Technical Description. . . . . . . . . . . . . . . . . . . . 9
2.4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3. Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1 Operating System Installation . . . . . . . . . . . . 10
3.2 System Installation . . . . . . . . . . . . . . . . . . . . . 10
4. Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.1 Electrical Interface Selection . . . . . . . . . . . . . 14
4.2 Switch Examples . . . . . . . . . . . . . . . . . . . . . . . 15
Appendix A. Troubleshooting. . . . . . . . . . . . . . . . . 16
A.1 Before Calling Technical Support . . . . . . . . 16
A.2 Calling Black Box . . . . . . . . . . . . . . . . . . . . . . 17
A.3 Shipping and Packaging . . . . . . . . . . . . . . . . 18
Appendix B. Electrical Interfaces . . . . . . . . . . . . . . 19
Appendix C. Asynchronous Communications . . . . 22
5
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
1. Specifications
1.1 General
®
Manufacturing: UL 94V0 rating; 100% electrically
tested; solder mask over bare copper or solder mask
over tin nickel.
Connectors: (1) DB25 male; (1) USB Type B
Indicators: LEDs: (1) USB Enabled, (1) TX, (1) RX
Mean Time Between Failures (MTBF): Greater than
150,000 hours
Temperature Tolerance: Operating: 32 to 122°F (0 to
50°C); Storage: -4 to +158°F (-20 to +70°C)
Relative Humidity: Operating and Storage: 10 to 90%
noncondensing
Power: Supply line: + 5 VDC; Rating: 50 mA
Size: 1"H x 2.3"W x 3.8"D (2.5 x 5.8 x 9.7 cm)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 1: Specifications
1.2 Connector Pin Assignments (DB25 Male)
Name
Pin #
Mode
GND
Ground
RX+
7
16
3
—
RDB
Receive Positive
Input
RDA
RX-
Receive Negative
Input
CTSB
CTSA
DSRB
DSRA
DCDB
DCDA
TDB
CTS+
CTS-
DSR+
DSR-
DCD+
DCD-
TX+
Clear to Send Positive
Clear to Send Negative
Data Set Ready Positive
Data Set Ready Negative
Data Carrier Detect Positive
Data Carrier Detect Negative
Transmit Positive
13
5
Input
Input
22
6
Input
Input
10
8
Input
Input
14
2
Output
Output
Output
Output
Output
Output
TDA
TX-
Transmit Negative
RTSB
RTSA
DTRB
DTRA
RTS+
RTS-
DTR+
DTR-
Request to Send Positive
Request to Send Negative
Data Terminal Ready Positive
Data Terminal Ready Negative
NOTE
19
4
23
20
These assignments meet EIA/TIA.ANSI-574 DTE
specifications for DB25 type connectors.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
2. Introduction
2.1 Overview
The USB Single-Port Hub (RS-422/485) equips the PC
with one USB to RS-530/422/485 asynchronous serial
port, providing a versatile interface for common
RS-530/422/485 needs. The advantage of this product
over more traditional approaches is that it doesn’t
require opening the computer case, nor does it require
resources such as I/O ports or IRQs. It does require a
system that supports USB both in terms of hardware and
operating system.
2.2 What the Package Includes
The USB Single-Port Hub (RS-422/485) is shipped with
the following items.
• USB Single-Port Hub (RS-422/485)
• USB cable for connecting to upstream host/hub
• Software
• This users’ manual
8
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 2: Introduction
2.3 Technical Description
The USB Single-Port Hub (RS-422/485) uses a USB
UART. This chip features programmable baud rate, data
format, a 128-byte dual-port TX buffer, and a 384-byte
dual-port RX buffer. The RS-422/485 transceiver
supports data rates up to 921.6 kbps.
2.4 Features
• Hot-pluggable device that doesn’t require opening
the case.
• No system resources are required (no I/O ports or
IRQs).
• LED status indicators for “USB Enabled,” “TX,”
and “RX.”
9
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
3. Installation
3.1 Operating System Installation
Choose Install Software at the beginning of the CD.
Select the Serial I/O software drivers and install
SeaCOM.
3.2 System Installation
The screen shots pictured in this section are taken from
®
a Windows Me installation. Your particular operating
system may differ slightly from what is shown based on
your version of Windows.
The USB Single-Port Hub (RS-422/485) can be
connected to any upstream Type “A” port either at the
PC host or an upstream hub. The Hub is hot-pluggable,
meaning there is no need to power down your computer
before installation.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 3: Installation
Connect the USB Single-Port Hub (RS-422/485) to an
upstream Host or Hub.
New Hardware Found
USB Single-Port Hub
Windows has found new hardware and is locating the software for it.
Figure 3-1. New Hardware Found screen.
This indicates that the system has recognized the new
device and will now locate a driver.
Add New Hardware Wizard
Windows has found the following new hardware:
USB Single-Port Hub
Windows can automatically search for and install software
that supports your hardware. If your hardware came with
installation media, insert it now and click Next.
What would you like to do?
Automatic search for a better driver (Recommended)
Specify the location of the driver (Advanced)
< Back
Next>
Cancel
Figure 3-2. Add New Hardware Wizard screen.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
Since you have already installed the software by running
“Setup,” simply click “Next” to proceed. The drivers that
were installed during setup will automatically be used to
configure the adapter.
Add New Hardware Wizard
USB Single-Port Hub
Windows has finished installing the new hardware device.
< Back
Finish
Cancel
Figure 3-3. Hardware installation finished screen.
Windows has now located a driver and installed the
software. Click “Finish” to proceed. You should see one
more “New Hardware Found,” indicating the actual port
being created. If you view your system’s Device Manager
at this point, you should have a new “COM” port in the
Ports (COM & LPT) Device Class. It should look similar
to the illustration on the next page.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 3: Installation
System Properties
General Device Manager Hardware Profiles Performance
View device by type
Computer
View device by connection
CD ROM
Disk Drives
Display adapters
Floppy disk controllers
Hard disk controllers
Keyboard
Monitors
Mouse
Multi-function adapters
Network adapters
Ports (C0M & LPT)
Communications Port (C0M1)
Printer Port (LPT1)
USB Single-Port Hub (C0M5)
SCSI controllers
Properties
Refresh
Remove
Print
OK
Cancel
Figure 3-4. System Properties, Device Manager tab.
You can access your new COM port by using the
assigned COM identifier. In this case, it is COM5: but
this assignment will vary from system to system. At this
point, the hardware is recognized. To verify operation,
use the supplied WinSSD diagnostic utility. WinSSD can
be found in the Start, Programs group.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
4. Configuration
4.1 Electrical Interface Selection
The port on the USB Single-Port Hub (RS-422/485) can
be used as RS-530/422/485, RS-422, or 2-wire RS-485.
This is selectable via the DIP-switch SW1. The chart
below describes each of the positions’ functions. Please
refer to the next page for switch setting examples.
Switch SW1 ON enables, adds, and connects. SW1
position OFF disables, removes, and disconnects.
SW1
Function
1
2
3
4
RS-485 two-wire auto enable/disable (ON=Enable).
Echo enable/disable (ON=Disable).
Adds or removes the 120-ohm termination.
Adds or removes the 1 Kohm pull-up resistor in the
RS-422/RS-485 receiver circuit (Receive data only).
5
Adds or removes the 1 Kohm pull-down resistor in the
RS-422/RS-485 receiver circuit (Receive data only).
6
7
8
Connects TX+ to RX+ for RS-485 two-wire operation.
Connects TX- to RX- for RS-485 two-wire operation.
Not used.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER 4: Configuration
4.2 Switch Examples
Please use these examples to configure your USB Single-
Port Hub (RS-422/485).
Figure 4-1. RS-530/422, 4-wire 485 master (default).
Figure 4-2. RS-485, 2-wire with echo.
Figure 4-3. RS-485, 2-wire no echo.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
Appendix A. Troubleshooting
A.1 Before Calling Technical Support
Serial Utility test software is supplied with the USB
Single-Port Hub (RS-422/485) and will be used in the
troubleshooting procedures. Using this software and
following these simple steps, most common problems
can be eliminated without calling Technical Support.
1. If your adapter isn’t working, first check to make
sure that USB support is enabled in the system
BIOS and it is functioning properly in the
operating system. This can be done by using either
the Windows 98, Me, or Windows 2000 Device
Manager.
2. Make sure that the systems software has been
installed on the machine so that the necessary files
are in place to complete the installation.
3. When the USB Single-Port Hub (RS-422/485) is
configured properly, the USB Enabled LED (EN)
will be lit. This should allow you to use the
WinSSD utility and the supplied loopback plug to
check communications. The supplied loopback
plug connects TX to RX. If you decide to test the
16
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX A: Troubleshooting
Modem Control Signals, a full pin loopback plug
will be required. Details on loopback plugs are
included within WinSSD.
4. When testing the USB Single-Port Hub
(RS-422/485) in loopback mode, you should see
both the TX and RX LEDs flashing as well as
seeing echoed data on the screen. The loopback
test first transmits a HEX pattern, 55AA, and then
an ASCII string of data. If this test passes, then the
Hub is ready for use in your application.
5. Please note that if the card is configured for 2-wire
RS-485 with no echo, a loopback test is not
possible. The receiver in this case will be turned
off and the test will fail. If you plan on using this
device in two-wire mode, test the hub in RS-422
mode first. Then configure the hub for your
application.
A.2 Calling Black Box
If you determine that your USB Single-Port Hub
(RS-422/485) is malfunctioning, do not attempt to alter
or repair the unit. It contains no user-serviceable parts.
Contact Black Box at 724-746-5500.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
Before you do, make a record of the history of the
problem. We will be able to provide more efficient and
accurate assistance if you have a complete description,
including:
• the nature and duration of the problem.
• when the problem occurs.
• the components involved in the problem.
• any particular application that, when used,
appears to create the problem or make it worse.
A.3 Shipping and Packaging
If you need to transport or ship your USB Single-Port
Hub (RS-422/485):
• Package it carefully. We recommend that you use
the original container.
• If you are shipping the USB Single-Port Hub
(RS-422/485) for repair, make sure you include
everything that came in the original package.
Before you ship, contact Black Box to get a Return
Authorization (RA) number.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B: Electrical Interfaces
Appendix B. Electrical Interfaces
RS-530
RS-530 (EIA-530) compatibility means that RS-422 signal
levels are met, and the pinout for the DB25 connector is
specified. The EIA (Electronic Industry Association)
created the RS-530 specification to detail the pinout,
and define a full set of modem control signals that can
be used for regulating flow control and line status. The
RS-530 specification defines two types of interface
circuits. Data Terminal Equipment (DTE) and Data
Circuit-Terminating Equipment (DCE). The USB
Single-Port Hub (RS-422/485) is a DTE interface.
RS-422
The RS-422 specification defines the electrical
characteristics of balanced voltage digital interface
circuits. RS-422 is a differential interface that defines
voltage levels and driver/receiver electrical
specifications. On a differential interface, logic levels are
defined by the difference in voltage between a pair of
outputs or inputs. In contrast, a single-ended interface,
for example, RS-232, defines the logic levels as the
difference in voltage between a single signal and a
19
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
common ground connection. Differential interfaces are
typically more immune to noise or voltage spikes that
may occur on the communication lines. Differential
interfaces also have greater drive capabilities that allow
for longer cable lengths. RS-422 is rated up to 10 Mbps
and can have cabling 4000 feet long. RS-422 also defines
driver and receiver electrical characteristics that will
allow one driver and up to 32 receivers on the line at a
once. RS-422 signal levels range from 0 to +5 volts.
RS-422 does not define a physical connector.
RS-485
RS-485 is backwardly compatible with RS-422; however, it
is optimized for partyline or multi-drop applications.
The output of the RS-422/485 driver is capable of being
Active (enabled) or Tri-State (disabled). This capability
allows multiple ports to be connected to a multi-drop
bus and selectively polled. RS-485 allows cable lengths
up to 4000 ft. and data rates up to 10 Mbps. The signal
levels for RS-485 are the same as those defined by
RS-422. RS-485 has electrical characteristics that allow
for 32 drivers and 32 receivers to be connected to one
line. This interface is ideal for multi-drop or network
environments. RS-485 tri-state driver (not dual-state) will
20
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX B: Electrical Interfaces
allow the electrical presence of the driver to be removed
from the line. Only one driver may be active at a time
and the other driver(s) must be tri-stated. RS-485 can be
cabled in two ways: two-wire and four-wire mode. Two-
wire mode does not allow for full-duplex
communication and requires that data be transferred in
only one direction at a time. For half-duplex operation,
the two transmit pins should be connected to the two
receive pins (TX+ to RX+ and TX- to RX-). Four-wire
mode allows full-duplex data transfers. RS-485 does not
define a connector pinout or a set of modem control
signals. RS-485 does not define a physical connector.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
Appendix C. Asynchronous
Communications
Serial data communications implies that individual bits
of a character are transmitted consecutively to a receiver
that assembles the bits back into a character. Data rate,
error checking, handshaking, and character framing
(start/stop bits) are pre-defined and must correspond at
both the transmitting and receiving ends.
Asynchronous communications is the standard means of
serial data communication for PC compatibles and PS/2
computers. The original PC was equipped with a
communication or COM: port that was designed around
an 8250 Universal Asynchronous Receiver Transmitter
(UART). This device allows asynchronous serial data to
be transferred through a simple and straightforward
programming interface. Character boundaries for
asynchronous communications are defined by a starting
bit followed by a pre-defined number of data bits (5, 6,
7, or 8). The end of the character is defined by the
transmission of a pre-defined number of stop bits
(usually 1, 1.5, or 2). An extra bit used for error
detection is often appended before the stop bits.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX C: Asynchronous Communications
Figure C-1. Asynchronous communications bit diagram.
This special bit is called the parity bit. Parity is a simple
method of determining if a data bit has been lost or
corrupted during transmission. There are several
methods for implementing a parity check to guard
against data corruption. Common methods are called
(E)ven Parity or (O)dd Parity. Sometimes parity is not
used to detect errors on the data stream. This is referred
to as (N)o parity.
Because each bit in asynchronous communications is
sent consecutively, it is easy to generalize asynchronous
communications by stating that each character is
wrapped (framed) by pre-defined bits to mark the
beginning and end of the serial transmission of the
23
Download from Www.Somanuals.com. All Manuals Search And Download.
USB SINGLE-PORT HUB (RS-422/485)
character. The data rate and communication parameters
for asynchronous communications have to be the same
at both the transmitting and receiving ends. The
communication parameters are baud rate, parity,
number of data bits per character, and stop bits (that is,
9600,N,8,1).
24
Download from Www.Somanuals.com. All Manuals Search And Download.
© Copyright 2001. Black Box Corporation. All rights reserved.
1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746
Download from Www.Somanuals.com. All Manuals Search And Download.
|