Black Box Film Camera LMC213A MMSC User Manual

WARNING!  
Negotiation/Manual” switch is in “Manual” position, the “Full-  
Duplex/Half-Duplex” switch determines the type of duplex  
operation mode. When the “Auto-Negotiation/Manual”  
switch is in “Auto-Negotiation” position, the “Full-Duplex/  
Half-Duplex” switch advertises its setting to the device  
connected to the UTP port. When set to “Half-Duplex”  
(factory setting), the FlexPoint will operate in half duplex.  
When set to “Full-Duplex” the FlexPoint will operate in full-  
duplex or half-duplex depending on the features supported  
by the other device.  
Overview and Description  
Before plugging the Power Adapter to any wall  
outlet or AC power source, verify that the power  
on the unit is appropriate for your AC line voltage  
source.  
The FlexPoint100Fx/Tx converts between Fast  
Ethernet 100Base-Fx fiber and 100Base-Tx twisted pair  
(RJ45 UTP) cabling. It operates in half-duplex (HD) or  
full-duplex (FD). The following multimode (MM) and  
single-mode (SM) models are described here:  
Mounting and Cable Attachment:  
LMC213A-MMSC  
LMC213A-MMST  
LMC213A-SMSC  
LMC213A-SMST  
LMC213AE-MMSC  
LMC213AE-MMST  
LMC213AE-SMSC  
LMC213AE-SMST  
LMC214A-SCP  
LMC214A-STP  
LMC214AE-SCP  
LMC214AE-STP  
Fiber/  
Connector  
Distance  
(HD)  
Distance  
(FD)  
The FlexPoint 100Fx/Tx can be individually wall-mounted  
using a wall-mounting kit, rack-mounted using a 5-position  
space-saver shelf, or inserted in a 14-position power-  
redundant FlexPoint Powered Chassis. When wall-  
mounting or shelf-mounting, attach the power adapter unit.  
Model  
LMC213A-MMSC  
LMC213A-MMST  
LMC213A-SMSC  
LMC213A-SMST  
MM/SC 412m/1,350ft.  
MM/ST 412m/1,350ft.  
SM/SC 412m/1,350ft.  
SM/ST 412m/1,350ft.  
2km/1.2mi.  
2km/1.2mi.  
25km /15mi.  
25km /15mi.  
Half-duplex must be used when connecting to a hub.  
Full-duplex can be used when connecting switches or  
between a switch and a full-duplex workstation.  
Attach the unit’s RJ45 UTP via a category 5 cable to a  
100Base-Tx Fast Ethernet device.  
LMC213AE-MMSC MM/SC 412m/1,350ft.  
LMC213AE-MMST MM/ST 412m/1,350ft.  
LMC213AE-SMSC SM/SC 412m/1,350ft.  
LMC213AE-SMST SM/ST 412m/1,350ft.  
2km/1.2mi.  
2km/1.2mi.  
25km /15mi.  
25km /15mi.  
LED Indicators:  
Attach the units’s fiber via cable to a 100Base-Fx Fast  
Ethernet device. The FlexPoint transmit (Tx) must attach  
to the receive side on the other device; the receive (Rx)  
must attach to the transmit.  
LED  
Color Description  
Power On  
Auto-Neg  
Yellow Power applied  
Green UTP switch is set to “Auto-Negotiation”  
position.  
LMC214A-SCP  
LMC214A-STP  
SM/SC 412m/1,350ft.  
SM/ST 412m/1,350ft.  
58km /35mi.  
58km /35mi.  
FlexPoint100Fx/Tx  
Full-Duplex Green Full-Duplex selected.  
Half-Duplex Green Half-Duplex selected.  
Fiber Lk/Rx Green Solid: Link  
LMC214AE-SCP  
LMC214AE-STP  
SM/SC 412m/1,350ft.  
SM/ST 412m/1,350ft.  
58km /35mi.  
58km /35mi.  
Switch Settings:  
“RJ45 Cross-Over” Switch: When connecting the UTP to  
ahuborswitch,settoStraight-Through(factorysetting). When  
connecting to a workstation, set it to “Cross-Over.”  
Installation and Configuration  
Power Adapter Notice:  
Flashing: Data received.  
Fiber Error Red  
UTP Lk/Rx Green Solid: Link,Flashing: Data received.  
UTP Error Red Data errors detected on UTP.  
Data errors detected on fiber.  
Order toll-free in the U.S.: Call 877-877-BBOX  
(outside U.S. call 724-746-5500)  
CUSTOMER  
SUPPORT  
INFORMATION  
1. When used in a stand-alone configuration, this  
product is intended to be used only with a Listed  
Direct Plug-In Power Unit marked “Class 2” and rated  
at 9Vdc, 1 Amp.  
“Auto-Negotiation/Manual” Switch: When in “Manual”  
(factory setting), the FlexPoint operation is selected by  
the “Full-Duplex/Half-Duplex” switch. When in “Auto-  
Negotiation”, the FlexPoint automatically selects full or  
half duplex operation depending on the “Full-Duplex/Half-  
Duplex” switch position and the features of the device  
connected to its UTP cable.  
FREE technical support 24 hours a day, 7 days a  
week; Call 724-746-5500 or fax 724-746-0746  
Mailing address: Black Box Corporation,  
1000 Park Drive, Lawrence, PA 15055-1018  
©Copyright 1999-2002. Black Box Corporation. All rights reserved.  
2. This product should always be used only with its  
enclosed Power Unit.  
1000 Park Drive l Lawrence, PA 15055-1018  
724-746-5500 l Fax 724-746-0746  
“Full-Duplex/Half-Duplex” Switch: When the “Auto-  
WARNING!  
Negotiation/Manual” switch is in “Manual” position, the “Full-  
Duplex/Half-Duplex” switch determines the type of duplex  
operation mode. When the “Auto-Negotiation/Manual”  
switch is in “Auto-Negotiation” position, the “Full-Duplex/  
Half-Duplex” switch advertises its setting to the device  
connected to the UTP port. When set to “Half-Duplex”  
(factory setting), the FlexPoint will operate in half duplex.  
When set to “Full-Duplex” the FlexPoint will operate in full-  
duplex or half-duplex depending on the features supported  
by the other device.  
Overview and Description  
Before plugging the Power Adapter to any wall  
outlet or AC power source, verify that the power  
on the unit is appropriate for your AC line voltage  
source.  
The FlexPoint100Fx/Tx converts between Fast  
Ethernet 100Base-Fx fiber and 100Base-Tx twisted pair  
(RJ45 UTP) cabling. It operates in half-duplex (HD) or  
full-duplex (FD). The following multimode (MM) and  
single-mode (SM) models are described here:  
Mounting and Cable Attachment:  
LMC213A-MMSC  
LMC213A-MMST  
LMC213A-SMSC  
LMC213A-SMST  
LMC213AE-MMSC  
LMC213AE-MMST  
LMC213AE-SMSC  
LMC213AE-SMST  
LMC214A-SCP  
LMC214A-STP  
LMC214AE-SCP  
LMC214AE-STP  
Fiber/  
Connector  
Distance  
(HD)  
Distance  
(FD)  
The FlexPoint 100Fx/Tx can be individually wall-mounted  
using a wall-mounting kit, rack-mounted using a 5-position  
space-saver shelf, or inserted in a 14-position power-  
redundant FlexPoint Powered Chassis. When wall-  
mounting or shelf-mounting, attach the power adapter unit.  
Model  
LMC213A-MMSC  
LMC213A-MMST  
LMC213A-SMSC  
LMC213A-SMST  
MM/SC 412m/1,350ft.  
MM/ST 412m/1,350ft.  
SM/SC 412m/1,350ft.  
SM/ST 412m/1,350ft.  
2km/1.2mi.  
2km/1.2mi.  
25km /15mi.  
25km /15mi.  
Half-duplex must be used when connecting to a hub.  
Full-duplex can be used when connecting switches or  
between a switch and a full-duplex workstation.  
Attach the unit’s RJ45 UTP via a category 5 cable to a  
100Base-Tx Fast Ethernet device.  
LMC213AE-MMSC MM/SC 412m/1,350ft.  
LMC213AE-MMST MM/ST 412m/1,350ft.  
LMC213AE-SMSC SM/SC 412m/1,350ft.  
LMC213AE-SMST SM/ST 412m/1,350ft.  
2km/1.2mi.  
2km/1.2mi.  
25km /15mi.  
25km /15mi.  
LED Indicators:  
Attach the units’s fiber via cable to a 100Base-Fx Fast  
Ethernet device. The FlexPoint transmit (Tx) must attach  
to the receive side on the other device; the receive (Rx)  
must attach to the transmit.  
LED  
Color Description  
Power On  
Auto-Neg  
Yellow Power applied  
Green UTP switch is set to “Auto-Negotiation”  
position.  
LMC214A-SCP  
LMC214A-STP  
SM/SC 412m/1,350ft.  
SM/ST 412m/1,350ft.  
58km /35mi.  
58km /35mi.  
FlexPoint100Fx/Tx  
Full-Duplex Green Full-Duplex selected.  
Half-Duplex Green Half-Duplex selected.  
Fiber Lk/Rx Green Solid: Link  
LMC214AE-SCP  
LMC214AE-STP  
SM/SC 412m/1,350ft.  
SM/ST 412m/1,350ft.  
58km /35mi.  
58km /35mi.  
Switch Settings:  
“RJ45 Cross-Over” Switch: When connecting the UTP to  
ahuborswitch,settoStraight-Through(factorysetting). When  
connecting to a workstation, set it to “Cross-Over.”  
Installation and Configuration  
Power Adapter Notice:  
Flashing: Data received.  
Fiber Error Red  
UTP Lk/Rx Green Solid: Link,Flashing: Data received.  
UTP Error Red Data errors detected on UTP.  
Data errors detected on fiber.  
Order toll-free in the U.S.: Call 877-877-BBOX  
(outside U.S. call 724-746-5500)  
CUSTOMER  
SUPPORT  
INFORMATION  
1. When used in a stand-alone configuration, this  
product is intended to be used only with a Listed  
Direct Plug-In Power Unit marked “Class 2” and rated  
at 9Vdc, 1 Amp.  
“Auto-Negotiation/Manual” Switch: When in “Manual”  
(factory setting), the FlexPoint operation is selected by  
the “Full-Duplex/Half-Duplex” switch. When in “Auto-  
Negotiation”, the FlexPoint automatically selects full or  
half duplex operation depending on the “Full-Duplex/Half-  
Duplex” switch position and the features of the device  
connected to its UTP cable.  
FREE technical support 24 hours a day, 7 days a  
week; Call 724-746-5500 or fax 724-746-0746  
Mailing address: Black Box Corporation,  
1000 Park Drive, Lawrence, PA 15055-1018  
©Copyright 1999-2002. Black Box Corporation. All rights reserved.  
2. This product should always be used only with its  
enclosed Power Unit.  
1000 Park Drive l Lawrence, PA 15055-1018  
724-746-5500 l Fax 724-746-0746  
“Full-Duplex/Half-Duplex” Switch: When the “Auto-  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Black Decker Air Compressor 641915 00 User Manual
Black Decker Vacuum Cleaner NS118 User Manual
Blodgett Convection Oven MARK V XCEL CONVECTION OVEN User Manual
Bodum Toaster 10709 User Manual
Bonavita Hot Beverage Maker BV382510V User Manual
Cambridge Audio Switch 840A User Manual
Canon All in One Printer MultiPASSTM C50 User Manual
Canon Digital Camera Z90W User Manual
Canon Network Router 80211g 54M WLAN User Manual
Casio Cash Register PCR T500 User Manual