P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 1
The Om niVie w™
SE 2-Port
Us e r Ma nua l
P73039
F1D102
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 2
Technical Specifications
Console Connectors:
Keyboard:
6 pin MiniDIN female
Mouse:
6 pin MiniDIN female (for PS/2 mouse)
DB9 male (for spare serial mouse)
HDDB15 female
Monitor:
Computer Port Connectors:
Keyboard:
6 pin MiniDIN female
Mouse:
6 pin MiniDIN female (for PS/2 mouse)
DB9 male (for serial mouse)
HDDB15 male
Monitor:
Dimensions:
Width:
9.5" (237 mm)
2.3" (58 mm)
6.0" (153 mm)
Height:
Depth:
Weight:
2.5 lbs (1.1 kg)
Operating Temp:
Storage Temp:
Humidity:
32 to 104 deg. F (0~40 deg. C)
-4 to 140 deg. F (-20 ~ 60 deg. C)
0~80% RH, non-condensing
2
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 3
Product Detail
FRONT PANEL
Current Active Port
LED Indicators
Bank Select/
Scan Button
Current Active Bank
LED Indicators
Port Select
Button
REAR PANEL
SLAVE INPUT
DB25 Daisy-chain port
MASTER INPUT
SLAVE OUTPUT
DB25 Daisy-chain port
Serial mouse
output
CONSOLE
connectors
PC PORT
connectors
VGA signal output
Optional
serial mouse
connector
VGA monitor
connector
DC power
jack
Keyboard
output
PS/2 mouse
output
DIP switches
Keyboard
connector
PS/2 mouse
connector
3
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 4
List of Parts Needed
Make sure you have the right cables!
The OmniView™ SE requires cables to connect the eight computers you will be controlling.
Below are the Belkin part numbers and their descriptions. We recommend purchasing Cable
Kits based on the type of mouse port your computer uses. Cable kits have all the cables you
need to connect one computer to the OmniView™ SE:
PS/2 Cable Kit - A3X982
Includes:
• 2 x F2N036-06
6 pin MiniDIN
• 1 x F2N025-06-T
HDDB15
AT Cable Kit - A3X939
5 pin DIN
Includes:
• 1 x F3A510-06
DB9
• 1 x F2N025-06-T
• 1 x F2N209-06-T
HDDB15
• 1 x F2N017
(see below for descriptions of each)
Individual Cables and Adapters:
• PS/2 cable for keyboard and mouse ports
Daisy-Chain Cable
6 pin MiniDIN male/male
Part# F2N036-XX
• DB25 Male/Male,
2’ (61cm) with ferrite
Part # F1D108-CBL
• Standard VGA cable for monitor port
HDDB15 male/female with thumbscrews
Part# F2N025-XX-T
Optional 19" (48.3cm) Rackmount Kit
• Serial extension cable for serial mouse
DB9 male/female with thumbscrews
Part# F2N209-XX-T
• 19" (48.3cm), 1.5u high
Part # F1D103
• AT keyboard cable for AT-style keyboard port
5 pin DIN male/male
Part# F3A510-XX
• AT to PS/2 keyboard adapter
5 pin DIN female/6 pin MiniDIN male
Part# F2N017
5 pin
DIN Female
6 pin MiniDIN Male
Other Cables and Adapters:
• High-resolution/high-refresh rate VGA cable for monitor port
HDDB15 male/female with thumbscrews
Part# A3H981-XX
• PS/2 to AT keyboard adapter - for use with a computer having an AT-style keyboard port
6 pin MiniDIN female/ 5 pin DIN male
Part# F2N018
6 pin MiniDIN Female
5 pin DIN Male
NOTE: The "XX" in the part number represents the length in feet.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 5
Hardware Installation
PLEASE FOLLOW THIS INSTALLATION PROCEDURE EXACTLY. NOT DOING SO MAY
RESULT IN KEYBOARD AND/OR MOUSE ERRORS, OR FAULTY OPERATION.
WARNING: Before attempting to connect anything to the OmniView™ SE or
the computers, make sure everything is powered off. Plugging and unplugging
cables may cause irreversible damage to your computers and the OmniView™ SE.
Belkin Components will not be held responsible for damage caused.
1. Set the DIP switches. If you have only one OmniView™ SE, use the MASTER bank
setting. If the OmniView™ SE you are using will be daisy-chained off another unit, use a
unique slave setting. Please refer to the next section for more information regarding
multiple OmniView™ SE units.
DIP switches 1 & 2 set the SCAN_TIME. See the USAGE section regarding
this setting.
DIP SWITCH SETTINGS
BANK ADDRESS
Use this setting if
you have only one
OmniView™ SE
1
2
3
4
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
OFF
BANK 0
BANK 1
BANK 2
BANK 3
MASTER
Slave
Slave
Slave
NOTE: ON is down
2. Find a convenient place to put your OmniView™ SE. Take note of the length of your
cables so that your computers, OmniView™ SE, keyboard, mouse, and monitor are
distanced properly.
3. Connect the monitor to the OmniView™ SE. Using the attached cable, or the one
included with your monitor, connect it to the HDDB15 female port on the back of the
OmniView™ SE labeled with the monitor symbol at the CONSOLE section.
Monitor
5
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 6
Hardware Installation (continued)
4. Connect the keyboard and mouse to the OmniView™ SE. If you have an AT-style
keyboard, you will need an AT-PS/2 adapter (Belkin Part# F2N017).
Back of OmniView™ SE
PS/2 Style Keyboard
PS/2 Mouse
5. Connect the first computer's VGA cable to the OmniView™ SE. Using the VGA cable
(Belkin Part# F2N025-XX-T or A3H981-XX), connect the male end of the cable to the
VGA port on the computer, and the female end on the PC1 VGA port at the back of
OmniView™ SE.
Back of PC
Back of OmniView™ SE
F2N025-XX-T
6. Connect the first computer's mouse cable to the OmniView™ SE. If using a PS/2 cable
(Belkin Part# F2N036-XX), connect one end to the PS/2 mouse port on the computer,
and the other end to the PC1 PS/2 mouse port on the back of the OmniView™ SE. If
using a serial mouse cable (Belkin Part# F2N209-XX-T), connect one end to a DB9 serial
port on the computer, and the other end to the PC1 DB9 serial mouse port on the back
of the OmniView™ SE.
Back of PC
Back of OmniView™ SE
F2N209-XX-T for serial mouse
OR
F2N036-XX for PS/2 mouse
6
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 7
Hardware Installation (continued)
7. Connect the first computer's keyboard cable to the OmniView™ SE. If using a PS/2
cable (Belkin Part# F2N036-XX), connect one end to the PS/2 keyboard port on the
computer, and the other end to the PC1 keyboard port on the back of the OmniView™
SE. If your computer has an AT-style keyboard port, you will need a PS/2-AT keyboard
adapter (Belkin Part# F2N018). If using an AT-cable (Belkin Part# F3A510-XX), connect
one end to the AT keyboard port on the computer, and the other end to an AT to
PS/2 keyboard adapter (Belkin Part# F2N017). Then, connect the adapter to the PC1
keyboard port on the back of the OmniView™ SE.
Back of PC
Back of OmniView™ SE
F2N036-XX
8. Double check all the connections. Make sure the keyboard and mouse cables go to the
correct ports.
9. Repeat steps 5-7 for the remainder of the computers.
10. Attach the power supply to the power supply connector at the back of the
OmniView™ SE. Plug this into any available AC outlet. You should see the LED or Port 1
on the front panel blink, and hear a beep. Power up your monitor.
11. You can now power up all of your computers simultaneously. The first computer will
show up on the monitor. Check to see if the keyboard and mouse work, as well as the
image displayed on the screen. If this is okay, press the CHANNEL button and check
the functionality of the other computers. If you find any errors, double-check all of the
cable connections.
NOTE: Avoid pressing any keys on the keyboard or moving the mouse if the currently
selected port has a computer that is in the process of booting up. This may cause
the computer to not detect, or initialize the keyboard or mouse drivers properly.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 8
Usage
(SKIP IF YOU HAVE ONLY ONE OmniView ™ SE)
Bank 0 (Master)
1
3
2
4
Bank 1 (slave)
Bank 2 (slave)
Bank 3 (slave)
5
9
6
CONSOLE
Keyboard,
mouse and
monitor
7
8
10
11
12
The OmniView™ SE has the capability to be daisy-chained to additional units for control over
more computers. Up to four OmniView™ SE units can be daisy chained together, whether
2-Port, 4-Port, or a mixture of both. The example above shows two OmniView™ SE 2-Port units
and two OmniView™ SE 4-Port units daisy-chained together.
Each OmniView™ SE unit is defined as a BANK. See diagram above for more information.
BANK numbers range from 0 to 3 for a total of 4 BANKs. BANK 0 is the MASTER bank, while
banks 1 through 3 are slave banks. The MASTER bank is the unit that connects to the console
keyboard, mouse, and monitor.
The DIP switches must be set correctly for proper identification and usage. See page 5 for the
actual settings. If you are using the OmniView ™ SE in a single-unit configuration, it must be
set as the MASTER (BANK 0). If it is to be used as a slave unit, then it must be set to any
unused unique bank number from 1 through 3.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 9
Usage (continued)
Daisy-chaining OmniView™ SE units with an OmniView™ PRO
Bank 0 (Master)
1
9
2
3
4
5
6
7
8
Bank 1 (slave)
Bank 2 (slave)
Bank 3 (slave)
10
14
16
11
12
CONSOLE
Keyboard,
mouse and
monitor
13
15
17
18
The OmniView™ SE is designed to be able to cascade with the OmniView™ PRO as well. In
such a scenario, it is recommended that the OmniView™ PRO be the MASTER unit, and the
OmniView™ SE units be slave units. This is shown in the diagram above. The OmniView™ PRO
is an 8-Port, 19" (48.3cm) rackmountable OmniView™, having the same features as the
OmniView™ SE, but adding On-Screen Display. When the OmniView™ PRO is used as
MASTER, all of the other OmniView™ units in the chain will benefit from the On-Screen
Display of the MASTER OmniView™ PRO.
When the OmniView™ PRO is used as the MASTER unit, 15 more OmniView™ units
(SE and/or PRO) can be daisy-chained to the master. Only BANKs 1 to 3 can be used by
OmniView™ SE units. BANKs 4 to 15 must be used by PRO units.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 10
Usage (continued)
Adding Slave Units
This assumes you already have a MASTER unit (or MASTER and slave units) set-up and
working properly. Below is the procedure of daisy-chaining a new slave unit.
• Set the DIP switches of the slave unit to a unique slave BANK setting.
• Connect the computers using the same procedure outlined in steps 5 to 9 in the
Hardware Installation section, page 6. DO NOT POWER UP THE COMPUTERS YET.
• Connect the power supply to the OmniView™ SE, and plug it into any available AC outlet.
This is necessary to initialize the unit. You will see the LED display on the front panel show
the unit’s bank address setting.
• Using the F1D108-CBL daisy-chain cable, connect one end to the "Master Input/Slave
Output" of the unit. Refer to the diagram on page 11.
• If the previous unit is the MASTER, then the other end of the cable connects to the
Master Input/Slave Output port of the MASTER (such as cable 1 in the diagram on
page 11).
• If the previous unit is a slave, then the other end goes to the Slave Input port of the
previous slave unit (such as cables 2 and 3 in the diagram on page 11).
• RESET the MASTER unit by pressing the BANK/SCAN and CHANNEL buttons
simultaneously. This is necessary for the MASTER unit to detect the newly added slave unit.
• Verify that the MASTER unit has detected the new slave by pressing the BANK/SCAN
button. If it detected the new slave properly, the LED "1" on the new slave unit will blink. If
you have many slave units, you may have to press the BANK/SCAN button a couple of times
to cycle through the preexisting slave units before reaching the newly added unit.
• Now you can power up the computers connected to the newly added slave unit. After all of
the computers have booted up, you may need to RESET the MASTER unit again to detect
the presence of powered computers on the new slave unit.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 11
Usage (continued)
Daisy-Chaining the OmniView ™ SE:
MASTER
(Bank 0)
Cable 1
slave
(Bank 1)
Cable 2
slave
(Bank 2)
Cable 3
slave
(Bank 3)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 12
Usage (continued)
Selecting which computer to operate can be done either by the CHANNEL button, or through
keyboard “Hot” key commands. You will notice that after the OmniView™ SE switches to
another computer, the mouse will be inoperative for about 1-2 seconds. This is normal
operation and ensures that proper mouse synchronization is established.
The CHANNEL Button:
Pressing the CHANNEL button cycles you through all the ports, including inactive ports.
1
2
The BANK/SCAN Button:
Pressing the BANK/SCAN button cycles you through all the active BANKs (if there are slave
units present) and then puts the unit in AutoScan mode. If the unit is a single MASTER unit,
pressing the button immediately invokes AutoScan mode. This is evident by a long BEEP,
followed by two short beeps.
Keyboard “Hot” Key commands:
You can also conveniently command the OmniView™ SE to switch ports through simple
keyboard key sequences. To send commands to the OmniView™ SE, the SCROLL LOCK key
must be pressed twice within 2 seconds. You will hear a beep for confirmation. Below are the
different commands:
Switch to PREVIOUS ACTIVE port
(on the same BANK)
Switch to NEXT ACTIVE port
(on the same BANK)
Switch to the PREVIOUS BANK
(by default, selects first active port on that BANK)
Switch to the NEXT BANK
(by default, selects first active port on that BANK)
Directly switches to port Y on BANK X
(x={0-3}, y={1-4})
12
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 13
Usage (continued)
You can switch directly to any port by giving the OmniView™ SE the BANK and PORT
numbers. For instance, if you press [SCROLL LOCK] [SCROLL LOCK] [2] [2], the
computer on PORT 2 of the OmniView™ SE set to BANK 2 will be selected. In the
diagram below, that is PC # 8. Hence, if you only have one OmniView™ SE, the first key (X)
must be "0".
Bank 0 (Master)
1
3
2
4
Bank 1 (slave)
Bank 2 (slave)
Bank 3 (slave)
5
9
6
CONSOLE
Keyboard,
mouse and
monitor
7
8
10
11
12
AutoScan Mode
Enable AutoScan mode
In AutoScan mode, the OmniView™ SE remains on one port for a number of seconds, before
switching to the next. Set DIP switches 1 & 2 using the table below according to a
SCAN_TIME interval you prefer. If there are slave units present, the SCAN_TIME setting is
set on the MASTER unit only, and need not be set on the slave units.
DIP SWITCH #
SCAN_TIME
1
2
ON
ON
OFF
OFF
ON
OFF
ON
OFF
7 seconds
15 seconds
30 seconds
60 seconds
NOTE: There is no mouse or keyboard control in this mode. This is necessary to
prevent errors. Otherwise, if the user is moving the mouse or using the keyboard
when the OmniView™ SE switches to the next port, data flow is interrupted and will
cause erratic mouse movement and/or the wrong characters to show up when using
the keyboard.
To get out of AutoScan mode, press the SPACEBAR.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 14
Troubleshooting
General Problems:
Q: When cascading, the MASTER unit does not see the slave unit(s).
A: • Refer to the Hardware Installation section for information on how to properly connect
the daisy-chain cable.
• Make sure that the daisy-chain cable that you are using is the F1D108-CBL. Using any
other cable will not guarantee proper operation or video quality.
• RESET the MASTER OmniView™ SE (or OmniView™ PRO), whichever the case may be.
Monitor/Video Problems:
Q: I am getting ghosting, shadowing or fuzzy images on my monitor. What do I do?
A: • Check the cables and make sure they are inserted properly.
• Your resolution and/or refresh rate is extremely high, or your cable is too long. Replace
your VGA cables with coaxial, double-shielded cables such as Belkin A3H981-XX.
• Check to make sure that the power adapter is plugged in and is working properly.
It must be 9VDC, 600mA minimum. Make sure the power switch is on.
• Lower your refresh rate and/or screen resolution settings.
Keyboard Problems:
Q: The keyboard is not detected, or a keyboard error is reported during boot-up.
A: • Check the cables and make sure they are inserted properly in the correct ports.
• Check to make sure that the power adapter is plugged in and is working properly.
It must be 9VDC, 600mA minimum. Make sure the power switch is on.
• RESET the OmniView™ SE by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel.
• Do not press any keys on the keyboard while the selected computer is booting up.
This is true for any PC, whether stand-alone or connected to a KVM switch.
Q: The computers boot up fine, but the keyboard does not work.
A: • Check the cables and make sure they are inserted properly in the correct ports.
• Make sure the keyboard works when directly plugged into the computers.
• Try a different keyboard, but use only 101, 102 or 104-key keyboards.
• Make sure that the keyboard driver is for 101, 102 or 104-key keyboards, and not old
XT keyboards.
• Check to make sure that the power adapter is plugged in and is working properly. It
must be 9VDC, 600mA minimum. Make sure the power switch is on.
• RESET the OmniView™ SE by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel.
PS/2 Mouse Problems at the Console or Computers:
Q: The mouse is not detected during boot-up.
A: • Check the cables and make sure they are inserted properly in the correct ports.
• Check your computer/motherboard documentation making sure that the PS/2 mouse
port (or IRQ) is enabled.
• Make sure the mouse is directly plugged into the computer. Rebooting is necessary
when trying this. If the computer still does not detect the mouse, then your computer’s
PS/2 mouse port has a problem.
• RESET the OmniView™ SE by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 15
Troubleshooting (continued)
Q: The computers boot up fine, but the mouse does not work.
A: • Check the cables and make sure they are inserted properly in the correct ports.
• Make sure the mouse works when directly plugged into the computer. Rebooting is
necessary when trying this. If the mouse pointer still does not move, then either your
PS/2 mouse port or the mouse itself has a problem.
• Try a different mouse.
• Make sure the mouse is a true PS/2 mouse. A combo mouse will work just as long as it
is set for PS/2 mode with the correct adapter. A serial-only mouse with a combo
mouse adapter will not work.
• Check to make sure that the power adapter is plugged in and is working properly. It
must be 9VDC, 600mA minimum. Make sure the power switch is on.
• RESET the OmniView™ SE by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel.
• Switch to another computer port, then switch back. This is another method of
re-initializing the mouse.
Q: When I switch from one port to another, mouse movement is completely erratic.
What do I do?
A: • Switch to another port, then switch back to the previous port. This can resynchronize
the mouse.
• RESET the OmniView™ SE by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel.
• Make sure you do not have more than one mouse driver. Make sure that the driver is
either for a Standard PS/2 or Microsoft®-compatible PS/2 mouse. Try to obtain the
latest version from your hardware manufacturer.
• If you are using a specialized mouse such as a cordless mouse, scrolling mouse or mice
with more than 2 operational buttons, use generic PS/2 mouse drivers. Non-standard
mice often use non-PS/2 proprietary mouse protocol.
• Make sure you do not have any mouse drivers loaded in your config. sys or
autoexec.bat files.
• Avoid moving the mouse or pressing the mouse buttons when switching ports.
• Reset the mouse to resume proper mouse movement simply by unplugging the mouse
from the OmniView™ SE for about 2-3 seconds, and plugging it in again.
• Switch to another computer port, then switch back. This is another method of
re-initializing the mouse.
Problems with computers using the serial mouse output:
Note: The OmniView™ SE has Integrated Mouse Conversion Technology. This technology
converts the PS/2 mouse signals at the console to serial mouse signals. Windows® 9x
Control Panel System applet may not display that it has detected a mouse, but the
Modem applet will show a serial mouse at a certain serial port.
Q: The computers boot up fine, but the mouse does not work.
A: • Switch to another computer port, then switch back. This is another method of
re-initializing the mouse.
• Check the cables and make sure they are inserted properly in the correct ports.
• Check the cable and make sure that it is a straight-through DB9 male/female cable
such as Belkin Part# F2N209-XX-T (XX is the length in feet).
• Check your computer/motherboard documentation making sure that the serial ports
are enabled, and that there are no IRQ or base address conflicts with other serial ports
or modems.
• Plug in a serial mouse directly to your computer, and reboot. If the mouse pointer still
does not move, then there maybe no serial mouse drivers installed, or the serial port
on your computer may have other conflicts or problems.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 16
Troubleshooting (continued)
• Try a different PS/2 mouse at the console.
• Make sure the mouse (at the console) is a true PS/2 mouse. A combo mouse will work
just as long as it is set for PS/2 mode with the correct adapter. A serial-only mouse with
a combo mouse adapter WILL NOT work.
• Check to make sure that the power adapter is plugged in and is working properly. It
must be 9VDC, 600mA minimum. Make sure the power switch is on.
• RESET the OmniView™ SE by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel.
Q: When I switch from one port to another, mouse movement is completely erratic.
What do I do?
A: • RESET the OmniView™ SE by simultaneously pressing the BANK/SCAN and CHANNEL
buttons on the front panel.
• Make sure you do not have more than one serial mouse driver loaded. Make sure that
the driver is either for a Standard Serial or Microsoft®-compatible serial mouse.
• Avoid using a specialized mouse at the console such as a cordless mouse,
scrolling mouse or mice with more than 2 operational buttons. Non-standard mice often
use non-PS/2 proprietary mouse protocol.
• Make sure you do not have any other mouse drivers loaded in your config.sys or
autoexec.bat files.
• Avoid moving the mouse or pressing the mouse buttons when switching ports.
• Reset the mouse to resume proper mouse movement simply by unplugging the mouse
from the OmniView™ SE for about 2-3 seconds, and plugging it in again.
• Switch to another computer port, then switch back. This is another method of
re-initializing the mouse.
Q: The wheel on the IntelliMouse® does not work on my computer. Why?
A: • The Integrated Mouse Conversion Technology converts only the standard PS/2 signals
which are the buttons and the x and y coordinate movement, but not the wheel
movement or wheel button. This is because the wheel and wheel button data use
non-PS/2 protocol.
Note about the Optional Serial Mouse port at the console:
If you have tried all possible troubleshooting methods, you can plug in a serial mouse (as
a second mouse) at the optional serial mouse input port. See the Product Detail section,
page 3, for the diagram. This mouse will be directly connected to the serial mouse ports
on the OmniView™ SE. Note that the serial mouse signals will not be converted to PS/2
mouse signals, so if you have other PCs using PS/2 mouse ports, you must keep the
PS/2 mouse at the console. This serial mouse is a second mouse, and is active only
when on a computer that uses the serial mouse output.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
P73039_F1D102-eng_man.qxd 9/26/00 3:42 PM Page 17
Information
FCC Statement
DECLARATION OF CONFORMITY WITH FCC RULES FOR ELECTROMAGNETIC COMPATIBILITY
We, Belkin Components, of 501 West Walnut Street, Compton CA 90220, declare under our sole
responsibility that the product:
F1D102
to which this declaration relates:
Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
CE Declaration of Conformity
We, Belkin Components, declare under our sole responsibility that the F1D102, to which this declaration relates, is in
conformity with Generic Emissions Standard EN50081-1 and with Generic Immunity Standard EN50082-1 1992.
Belkin Components One Year Product Warranty
Belkin Components warrants this product against defects in materials and workmanship for one year. If a defect is
discovered, Belkin will, at its option, repair or replace the product at no charge, provided it is returned during the
warranty period, with transportation charges prepaid, to the authorized Belkin dealer from whom you purchased the
product. Proof of purchase may be required.
This warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication; if the
product has been modified without the written permission of Belkin; or if any Belkin serial number has been removed
or defaced.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE IN LIEU OF ALL OTHERS, WHETHER
ORAL OR WRITTEN, EXPRESSED OR IMPLIED. BELKIN SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED
WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
No Belkin dealer, agent, or employee is authorized to make any modification, extension, or addition to this warranty.
BELKIN IS NOT RESPONSIBLE FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES RESULTING FROM
ANY BREACH OF WARRANTY, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST
PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPROGRAMMING, OR REPRODUCING ANY PROGRAM OR
DATA STORED IN OR USED WITH BELKIN PRODUCTS.
Some states do not allow the exclusion or limitation of incidental or consequential damages or exclusions of implied
warranties, so the above limitations of exclusions may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights that vary from state to state.
be lkin.com
Belkin Components, Ltd.
Belkin Components B.V.
Belkin Components
Unit 13 • Gatelodge Close • Round Spinney
Northampton • Northants • NN3 8RX • UK
Tel: +44 (0) 1604678300
Diamantlaan 8 • 2132 WV
Hoofddorp • The Netherlands
Tel: +31 (0) 235698765
501 West Walnut Street
Compton • CA • 90220 • USA
Tel: 310.898.1100
Fax: +44 (0) 1604678330
Fax: +31 (0) 235612694
Fax: 310.898.1111
© 2000 Belkin Components. All rights reserved. All trade names are registered trademarks of the respective manufacturers listed.