OPERATION
REAR PANEL (continued)
Switch On
Back-up
Protection Socket
Surge Protection
Socket
With the UPS plugged in, press and hold the on/off/test button for
more than three seconds until the "ON LINE" LED lights up to
switch the UPS on. The UPS will perform self-testing each time it
is switched on. Note: The UPS maintains a battery charge when in
the off position.
AC
Inlet
Switch Off
Press and hold the on/off/test button for more than three seconds
until the "ON LINE" or "ON BATTERY" LED goes off.
FOR MODELS
F6C350zSER-SB
F6C500zSER-SB
F6C650zSER-SB
Self-Test
Use the self-test to verify both the operation of the UPS and the
condition of the battery. In normal utility power, push the
on/off/test button less than two seconds and the UPS performs
a self-test function. During the self-test, the UPS operates in
“BACKUP” mode.
RJ11/RJ45
Circuit
Breaker
Communication
Port
Surge Protector
AC-Input Power Cord
Connect to the AC utility.
Note
During the self-test, the UPS briefly operates “ON BATTERY”
mode (the “REPLACE BATTERY” LED comes on). If the UPS
passes the self-test, it returns to “ON LINE” operation. The
“REPLACE BATTERY” LED goes off and the “ON LINE” LED goes
on steady. If the UPS fails the self-test, it immediately returns to
on-line operation and flashes the “REPLACE BATTERY” LED. The
loads are not affected. Recharge the battery overnight and
perform the self-test again. If the “REPLACE BATTERY” LED is still
on, the battery will need to be replaced; go to belkin.com.
AC Input Breaker (Circuit Breaker)
USER MANUAL
The circuit breaker button will stick out if an overload condition
forces the UPS to disconnect itself from utility power. If the button
sticks out, disconnect nonessential equipment.
Battery Back-up Sockets
Data-sensitive equipment such as a computer, monitor, and
external drive should be powered by these sockets. Battery power
is automatically provided in case of a power outage. Power (utility
or battery) is not supplied to these sockets when the UPS is
switched off. (Do not plug surge protectors, power strips, or laser
printers into the battery back-up sockets.)
Silence
In "BACK-UP" mode, push the on/off/test button less than three
seconds to silence the audible alarm. (The function is void when
under condition of "LOW BATTERY".)
One Surge-Protected Socket
Equipment such as a printer, fax machine, scanner, or a desk lamp
should be powered by this socket. This socket does not provide
power during a power outage. This socket is always on (when
utility power is available) and is not controlled by the front
panel switch.
INTRODUCTION
Have you ever noticed your lights dim or flicker when you turn
on your dishwasher or air conditioner? This common occurrence
is attributed to an under-voltage of power, also know as a
brownout.
A brownout is a period of insufficient power-line voltage. It is
the most common power problem, accounting for 80% of all
power disturbances.
Effects: A brownout can deprive a computer of the power it
needs to function, causing unwanted damage to your
computer–such as frozen keyboards and hard drive crashes.
Such problems will cause you to incur computer repairs, lost
data, and downtime.
Solution: A Belkin Uninterruptible Power Supply (UPS) unit
protects against surges, spikes, swells, line-noise, brownouts,
and blackouts! A surge protector can only protect your computer
from over-voltages due to irregular power!
Printer
CONNECTING EQUIPMENT
Computer
Connect the Loads
Plug the loads into the output connectors on the rear of the UPS.
To use the UPS as a master on/off switch, make sure all of the
loads are switched on.
Caution
Never connect a laser printer or scanner to the back-up sockets of
a UPS with other computer equipment. A laser printer or scanner
periodically draws significantly more power when in use than when
idle. This may overload the UPS.
Cash
Register
Lamp
CONNECTING THE
TELEPHONE/FAX/MODEM/DSL LINES
PRESENTATION
IMPORTANT SAFETY INSTRUCTIONS
Connect a single telephone/fax/modem/DSL line into the surge-
protected sockets on the back of the UPS. The RJ11 modular
sockets accept standard single-line telephone connections. This
connection will require another length of telephone cable
(supplied).
Please Read This Manual!
STEADY LIGHT
LED
MEANING
BLINKING
Thank you for purchasing the Belkin Uninterruptible Power
Supply (UPS). It will provide you with the best protection for
your connected equipment.
Utility is normal.
GREEN
ON LINE/
ON BATTERY
Utility is abnormal, supplies power to outlets
from battery source.
Please Save This Manual!
Note! This connection is optional but highly suggested as
phone/fax/modem/DSL lines often carry dangerous surges and
spikes. The UPS works properly without a phone/fax/modem
/DSL connection.
It includes important instructions for the safe use of this UPS
and for obtaining factory service should the proper operation of
the UPS come into question.
Battery capacity is low. The UPS will start
shutdown. The unit sounds an audible alarm.
LOW BATTERY/
Please Save or Recycle the Packaging Materials!
YELLOW
1. The LED flashes eight seconds. It means the
UPS is in the self-checking mode.
REPLACE
BATTERY
Caution! The telephone/fax/modem/DSL protection feature could
be rendered inoperable if improperly installed.
The UPS shipping materials were designed with great care to
provide protection from transportation-related damage. These
materials are invaluable if you ever have to return the UPS for
service. Damage sustained during transit is not covered under
the warranty.
Federal Communications Commission Interference Statement
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. To assure continued
compliance, use only shielded interface cables when connecting
to computer or peripheral devices. Any changes or modifications
not expressly approved by the party responsible for compliance
could void the user’s authority to operate this equipment.
2. The LED flashes more than 10 seconds.
It means the battery is bad or the charger
is at fault.
Make sure that the telephone line from the wall is plugged
into the connector marked "IN", and the device to be
protected (telephone/fax/modem) is plugged into the
connector marked "OUT".
There is a problem with the UPS. The LED
will be lit continuosly and the unit will
sound an audible alarm for 10 seconds.
FAULT/
RED
OVERLOAD
Battery ouput is drawing more power than
the UPS can provide.
INSTALLATION
Note
Before the installation, please inspect the UPS upon
receipt. Make sure that everything inside the package is
not damaged.
ALARM
Back-up (Slow Alarm)
Connect to Utility
Connect the AC inlet to utility power via the power cord.
Charge the Battery
For best results, charge the battery for six hours prior to
initial use. The UPS charges its battery whenever it is connected to
the utility power.
When in "BACK-UP" mode, the GREEN LED illuminates and the
UPS sounds an audible alarm. The alarm stops when the UPS
returns to LINE NORMAL operation.
Low Battery (Rapid Alarm)
In "BACK-UP" mode, when the battery energy runs low, the UPS
beeps rapidly until the UPS shuts down from a depleted battery or
returns to LINE NORMAL operation.
FRONT PANEL
Press the button longer than three seconds to turn the UPS on
or off. Press the button less than three seconds to activate the
UPS self-testing or to silence the backup alarm.
Overload (Continuous Alarm)
When the UPS is overloaded (the connected loads exceed the
maximum rated capacity) the UPS emits a continuous alarm to
warn of an overload condition. Disconnect nonessential equipment
from the UPS to eliminate the overload.
Fault (10 Seconds Continuously)
Fault/Overload
Low Battery/Replace Battery
When the output is shorted, the UPS emits a 10-second alarm.
Disconnect the equipment from the UPS prior to checking
the equipment.
COMMUNICATION INTERFACE
Belkin Sentry Bulldog Shutdown Management Software and
RS-232 cable can be used with this UPS. If used, connect the
interface cable to the computer interface port on the rear panel of
the UPS, and then connect to the serial port on your PC.
REAR PANEL
Interface Port
The communication port provides the following features:
1) Monitors charger status
2) Monitors UPS status
3) Monitors battery status and condition
4) Monitors the utility status
5) Provides power-switch function for power saving
Provides an RS-232 port to relay the signal to support DOS,
Windows®, and other operating systems.
Phone/Fax/Modem/DSL or Network Protection
Telephone/fax/modem lines are surge protected and provide
complete safety for Internet connection. One input and one output
allow two devices to be protected (i.e. modem and fax).
On Line/On Battery
On/Off/Test
Download from Www.Somanuals.com. All Manuals Search And Download.
BELKIN COMPONENTS USER LICENSE AGREEMENT
SOFTWARE OPTIONS
STORAGE
LICENSE: You have the non-exclusive right to use the software.
You are not permitted to copy, modify or transfer the software or
documentation. You may not decompile, disassemble or
otherwise reverse engineer, break down, analyze or modify the
software.
Belkin Sentry Bulldog Shutdown Management Software
Belkin Sentry Bulldog Shutdown Management Software receives
communication through the RS-232 interface port to perform
monitoring functions, and also provide an orderly shutdown of the
computer in the event of a power failure. Moreover, Belkin Sentry
Bulldog Shutdown Management Software displays all of the
diagnostic symptoms on screen, such as voltage level, frequency,
battery level, etc. The software is available for Windows® 95,
Windows® 98, Windows NT® V4 or higher, Windows® 2000,
Windows® Me, Unix®, and Novell® 3.X and above.
Storage Conditions
Store the UPS covered and upright in a cool, dry location,
with its battery fully charged. Before storing, charge the UPS
for at least four hours. Disconnect any cables connected to
the computer interface port to avoid unnecessary drainage of
the battery.
USE AND RESTRICTIONS: You are permitted to make backup
copies of all the software disks for archival purposes only. You
must reproduce the proprietary notice set forth on the disks and
affix them to all backup copies. You are not permitted to use
these programs in connection with a computer service, or to use
the backup copies other than as a replacement for the original
copy.
Extended Storage
During extended storage in environments where the ambient
temperature is 15˚ C to 30˚ C, charge the UPS battery every
six months.
Interface Kits
During extended storage in
environments where the
ambient temperature is
30˚ C to 45˚ C, charge
the UPS battery every three
months. Note:
Each interface kit includes a special interface cable which is
required to convert status signals from the UPS into signals that
the individual operation system can recognize. The interface cable
must be connected to the (RS-232) serial port on the UPS. The
other side of the interface cable can be connected to the DB9
serial port on your PC. For other installation instructions and
features, please refer to the READ.ME file.
TERM: This license is effective upon acceptance by opening this
envelope or in any other way using the enclosed software, which
will constitute your acceptance of, and agreement to, this
Agreement, and is effective until terminated. The limited license
in this Agreement will be automatically terminated if you fail to
comply with any of the terms and conditions in this Agreement.
You agree that upon such termination you will immediately
destroy all programs and documentation, including all copies
made or obtained by you.
Caution: Use only factory supplied or UPS monitoring cable!
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING
F6C350z
SER-SB
F6C500z
SER-SB
F6C650z
SER-SB
MODEL
RATED
CAPACITY
350VA/
190W
500VA/
300W
650VA/
360W
PROBLEM
POSSIBLE CAUSE
SOLUTION
UPS cannot
turn on.
UPS does not turn on properly. Press switch and hold longer
than three seconds.
RATED
VOLTAGE
INPUT
196-264VAC
Single Phase 50Hz
Simulated Sine Wave
50Hz
(No alarm, No Battery inside the UPS is bad. Replace with the same
LED lights) type of battery from belkin.com.
PHASE
FREQUENCY
LIMITED WARRANTY: Except for the limited replacement
warranty with respect to the disks expressly stated in the next
paragraph, THE PRODUCT, SOFTWARE, PROGRAM,
DOCUMENTATION, AND ANY RELATED INFORMATION, GOODS
OR SERVICES ARE PROVIDED "AS IS" WITH NO WARRANTY OR
REPRESENTATION OF ANY KIND WHATSOEVER. BELKIN
HEREBY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
UPS fault.
Call for service if the above
actions do not solve your
problems.
VOLTAGE
OUTPUT
BATTERY
FREQUENCY
UPS always at Power cord is loose.
Replace the power cord.
battery mode.
F6C350
Up to 15min
F6C500
Up to 20min
F6C650
Up to 25min
AC breaker is burned out
or tripped.
Replace or reset the breaker.
BACK-UP TIME
RECHARGE
TIME
AC utility voltage is too high,
too low, or blacked out.
Normal condition.
6 Hours to 90%
0~40°C
TEMPERATURE
HUMIDITY
Back-up time
too short.
Battery inside the UPS
is not fully charged.
Recharge the battery for
at least six hours.
ENVIRONMENT
10 ~ 90%
UPS is overloaded.
Remove some un-critical loads.
Replace battery at belkin.com.
Contact service personnel.
The entire risk of the use, results and performance of the
software, program and documentation is borne by you. Should
any or all of the product, software, program, documentation, or
related information, goods or services be defective, misused,
unsuitable or cause or give rise to any harm or liability
whatsoever, you, not Belkin or its associates, dealers or agents,
assume the entire liability, cost of repair, correction or any
payment or other remedy whatsoever. Furthermore, no warranty
or guarantee is made regarding the use or results of the product,
software, program, documentation, or any related information,
goods or services in terms of correctness, accuracy, reliability,
timeliness or otherwise. You use and rely on the program at your
own risk. The following is the only and exclusive warranty and
remedy of any kind: Belkin does warrant that the program disks
are free from physical defects in materials and workmanship
under normal use for a period of one (1) year from the date of
purchase, as evidenced by a copy of the sales receipt. Return the
defective disk or documentation with your receipt directly to
Belkin for a replacement.
The battery is weak.
EN 60950
ACA TS001-1997
ACA TS002-1997
PCT 200
Charger fault or other reason.
SAFETY
SAFETY
REGULATION
Low Battery.
LED blinks
more than 10
seconds.
Battery fault.
Charger fault.
Contact Belkin.
EMC
AS/NZS 3260:1993
DIMENSION
NET WEIGHT
7.1"W x 8.7"D x 2.4"H
Low Battery.
LED blinks
Contact Belkin.
APPEARANCE
2.9 KGS/
6.4 LBS
3.2 KGS/
7 LBS
3.2 KGS/
7 LBS
more than 10
seconds with
buzzer beeps.
All specifications are subject to change without prior notice.
BATTERY REPLACEMENT
SAFETY
EcoPower Service Program
In the event that the UPS needs a battery replacement, Belkin
offers its EcoPower Service Program. This program offers a
battery replacement on your UPS to ensure it is working properly
in protecting your connected devices. It also ensures that the
battery in the UPS is discarded of properly in an effort to keep our
environment clean. All participants in the program will receive a
two-year extended product warranty. Please call Belkin
Components for detailed information regarding the cost of the
program and shipping procedures.
CAUTION
!
•
•
•
Internal battery voltage is 12V DC. Used CSB HC1217W
(for 350VA), HC 1221W (for 500, 650VA).
UPS with user-replaceable batteries shall contain
detailed instruction for battery removal and installation.
The unit is intended for installation in a controlled
environment (temperature controlled, indoor area free
of conductive contaminants).
DISCLAIMER: Belkin or its associates will in no event be liable (i)
in any amount for lost profits or special, incidental, punitive or
consequential damages, or (ii) for any claim or damage of any
nature, or under any theory, whatsoever, in any amount in excess
of the purchase price you paid for the product. The warranties
and remedies here set are exclusive, and in lieu of all others oral
or written, express or implied. Some jurisdictions do not allow
exclusion or limitation of implied warranties or of liability for
incidental damages, so the foregoing limitations or exclusion
may not apply to you. This warranty gives you specific legal
rights which vary from jurisdiction to jurisdiction. HOWEVER,
YOU WAIVE SUCH RIGHTS, EXCEPT AS EXPRESSLY PROVIDED
UNDER THE TERMS AND CONDITIONS OF THIS AGREEMENT,
TO THE MAXIMUM EXTENT ALLOWED BY LAW.
Sealed lead battery. Battery must be recycled.
The Old Battery Must Be Recycled
Deliver the battery to an appropriate recycling facility or return it
to Belkin in the packing carton that came with your new battery.
Additional recycling information is provided with your new battery.
For Recycling Information
Inside the USA Call:
(800) Re-Use-Pb (738-7372)
Outside the USA Call:
1 (800) 244-4415
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL OR
CONTACT BELKIN COMPONENTS.
Pb
Pb
NONSPILLABLE
BELKIN COMPONENTS USER LICENSE AGREEMENT
1. Lay down the UPS. Use your
thumb to open the battery
cover on the bottom of the unit.
2. Grasp the tab attached to
the battery and slide the
battery out.
Belkin Components ("Belkin") thanks you for choosing one of our
products for your use. This User License Agreement
("Agreement") contains the terms and conditions under which
limited use of the product is licensed to you.
The license is governed by the laws prevailing in the State of New
York, without regard to its conflicts of laws principles.
PLEASE READ THIS NOTICE CAREFULLY
ACKNOWLEDGMENT: By opening the package on which this
Agreement is printed, or through which it is visible, you
acknowledge that you have read this Agreement, understand it,
and agree that this agreement is the complete and exclusive
statement of agreement between yourself and Belkin and
supersedes any prior agreements, oral or written, and any other
communications relating to the subject matter of this Agreement.
DO NOT OPEN THIS ENVELOPE OR USE ANY OF THE SOFTWARE
UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT. IF
YOU OPEN THE ENVELOPE, YOU ARE AGREEING TO THE TERMS
AND CONDITIONS SET OUT IN THIS AGREEMENT. IF YOU DO
NOT ACCEPT THESE TERMS AND CONDITIONS, YOU MUST
RETURN THE ENVELOPE UNOPENED AND WITH THE DISKS
INSIDE TO THE PARTY FROM WHOM YOU RECEIVED IT.
4. Put the battery cover back
and slide it into position.
3. Insert the replacement gently
into the UPS. Make sure the
battery is well connected!
MAINTENANCE
SEVERABILITY: Any term or provision of this Agreement or any
application thereof which may be prohibited or unenforceable by
law in a particular jurisdiction shall be interpreted and enforced
to the maximum extent allowed in such jurisdiction (which the
parties acknowledge could mean severing the provision from this
Agreement or, if allowed, enforcing it in a narrower form),
without affecting the remainder of this Agreement, or any other
application of such term or provision in such jurisdiction, or
application of such term or provision in any other jurisdiction.
• Normally, the life of a battery is 3-5 years. But extreme operating
conditions and environment may shorten its life span.
• When the UPS has been unused for some time, the battery
inside will discharge slightly. It is recommended to plug the UPS
into a wall socket to let the battery begin charging automatically.
• When cleaning the plastic case or front panel, use only a soft,
dry cloth. If the case or front panel is very dirty, use a neutral,
non-abrasive detergent.
• Do not use alcohol or ammonia-based solutions.
• When moving the UPS, always handle it with care.
SCOPE OF USE: In this Agreement, "software" means all machine
readable software programs and associated files in this package,
all modified versions of and upgrades or improvements to such
programs and all copies of such programs and files. You, a single
user opening this envelope ("You", "you" or "your"), may use the
software on a single central processing unit. You may not rent it,
loan it out, or lease it, nor use it on a multi-user system.
Belkin Components USA
800.223.5546
belkin.com/au
Belkin Components B.V.
Belkin Components
501 West Walnut St.
Compton • CA • 90220-5221 • USA
Tel: 310 898 1100 • Fax: 310 898 1111
Belkin Components, Ltd.
7 Bowen Cresent • West Gosford •
NSW 2250 • Australia
Belkin Components, Ltd.
Starparc Building • Boeing Avenue 333 •
1119 PH Schiphol-Rijk • The Netherlands
Tel.+31 (0)20 654 7300 • Fax.+31 (0)20 654 7349
Express Business Park • Shipton Way •
Rushden • NN10 6GL • United Kingdom
Tel:+44 (0)1933 35 2000 • Fax:+44 (0)1933 31 2000
Tel:+61 (2)4372 8600 • Fax:+61 (2)4325 4277
© 2002 Belkin Components. All rights reserved. All trade names are registered trademarks of respective manufacturers listed. P73579
Download from Www.Somanuals.com. All Manuals Search And Download.
|