Chapter 1- Introduction  
232SDD16 Features  
The 232SDD16 is a general purpose control module that is  
connected to your computer’s RS-232 serial port. The 232SDD16  
offers 16 discrete digital I/O lines. With these features, the module  
can be used to sense external ON/OFF conditions and to control a  
variety of devices.  
The digital outputs are CMOS/TTL compatible. The digital inputs  
are CMOS/TTL compatible. The digital I/O lines are available  
through a DB-25S (female) connector.  
The 232SDD16 connects to your computer’s RS-232 serial port  
through a DB-25S connector. The unit automatically detects baud  
rates from 1200 to 9600. A data format of 8 data bits, 1 stop bit and  
no parity is used.  
Configuration parameters are stored in non-volatile memory.  
The configuration parameters consists of I/O definitions, and output  
power-up states.  
Figure 1.2 - Simplified Block Diagram  
Packing List  
Examine the shipping carton and contents for physical damage.  
The following items should be in the shipping carton:  
1. 232SDD16 unit  
The unit may be powered by setting RTS and DTR high on the  
serial port. If the 232SDD16 cannot be powered using the  
handshake lines, it may be powered with +12Vdc through the 2.5mm  
jack or through the DB-25 I/O connector.  
2. Software  
3. This instruction manual  
If any of these items are damaged or missing contact B&B  
Electronics immediately.  
NOTE: When using an external supply, the supply should be  
connected only to specifically labeled power inputs (power  
jack, terminal block, etc.). Connecting an external power supply  
to the handshake lines may damage the unit. Contact technical  
support for more information on connecting an external power  
supply to the handshake lines.  
Figure 1.1 - 232SDD16 Module  
232SDD16-1005 Manual  
1
2
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
232SDD16 Specifications  
I/O Lines  
Total:  
16 (Factory default = inputs)  
Digital Inputs  
Voltage Range:  
Low Voltage:  
0 Vdc to 5 Vdc  
1.0 Vdc max.  
2.0 Vdc min.  
High Voltage:  
Leakage Current:  
1 microamp max.  
Digital Outputs  
Low Voltage:  
High Voltage:  
0.6 Vdc @ 8.3 milliamps (Sink)  
4.3 Vdc @ -3.1 milliamps (Source)  
Power Supply  
Input Voltage:  
External power:  
Port power:  
8 Vdc to 16 Vdc  
35 milliamps* @ 12Vdc  
15 milliamps* (The RS-232 RTS  
and DTR lines must be high to port  
power unit.)  
Doesn’t include the power consumption of external devices.  
Communications  
Standard:  
Baud Rate:  
Format:  
RS-232 (unit is DCE)  
1200 to 9600 (automatic detection)  
8 data bits, 1 stop bit, no parity  
DB25S (female)  
Connector:  
Size  
0.7" x 2.1" x 4.7"  
232SDD16-1005 Manual  
3
4
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 2.1 - 232SDD16 I/O Port Pinout  
Chapter 2 - Connections  
DB-25S  
Pin #  
DB-25S  
Pin #  
Function  
Function  
I/O #15  
This chapter will cover the connections required for the  
232SDD16. There are three sets of connections: digital I/O, serial  
port, and power supply. Do not make any connections to the  
232SDD16 until you have read this chapter.  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
No connection  
No connection  
No connection  
No connection  
No connection  
No connection  
Ground  
+12Vdc Input  
I/O #0  
I/O #1  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
I/O #14  
I/O #13  
I/O #12  
I/O #11  
I/O #10  
No connection  
I/O #9  
I/O #8  
I/O #7  
I/O #6  
I/O #5  
Digital I/O Connections  
Connections to the I/O lines are made through the DB25S  
(female) I/O port connector. Refer to Table 2.1. See Chapter 5 for  
I/O interfacing examples.  
Digital Inputs  
I/O #2  
I/O #3  
The digital input lines are CMOS/TTL compatible and can handle  
voltages from 0Vdc to +5Vdc.  
I/O #4  
Digital Outputs  
The digital output lines have a maximum voltage of +5Vdc and  
are CMOS/TTL compatible.  
Serial Port Connections  
In order to communicate to the 232SDD16 module it must be  
connected to an RS-232 serial port. The unit automatically detects  
baud rates from 1200 to 9600. A data format of 8 data bits, 1 stop  
bit and no parity is used. The 232SDD16 is configured as a DCE  
device (See Table 2.2). If your communications equipment is  
configured as a DTE device, such as a standard IBM PC serial port,  
the 232SDD16 should be connected using a “straight through” DB-  
25 cable or a standard DB-9 to DB-25 cable adapter as shown in  
Table 2.3. If your communications equipment is configured as a  
DCE device, such as a modem, the 232SDD16 should be connected  
using a “null modem” cable (See Table 2.4).  
Ground  
The pin should be connected to your external digital devices  
ground.  
232SDD16-1005 Manual  
5
6
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power Supply Connections  
Table 2.2 - RS-232 Connector Pinout  
Power to the 232SDD16 can be supplied by the RS-232 serial  
port handshake lines (RTS, DTR) or by an external power supply  
through the 2.5mm power jack or from the I/O connector. Most serial  
ports can provide enough power to supply the 232SDD16’s 15  
milliamp requirement. If you plan to use this method to power the  
unit, your software must set the RS-232 RTS and DTR lines to the  
high state. An external power supply must be able to supply 8 to 16  
Vdc at 35ma.  
Signal  
Direction at  
232SDD16  
DB-25S  
Pin #  
Signal  
Notes  
2
3
4
Transmit Data (TD)  
Receive Data (RD)  
Request to Send  
(RTS)  
Signal Ground (SG)  
Data Terminal  
Ready (DTR)  
Input  
Output  
Input  
Connection is required.  
Connection is required.  
May be used to power  
unit if kept high.  
Connection is required.  
May be used to power  
unit if kept high.  
7
20  
Input  
NOTE: Power requirements of the module does not include the  
power consumption of any external devices connected to the  
module. Therefore, any current that is sourced by the digital outputs  
must be added to this value and the current must not exceed the  
maximum output source current. Refer to the 232SDD16  
Specification Section of this manual.  
Table 2.3 - 232SDD16 To DTE Connections  
232SDD1  
6 Pin #  
DTE DB-  
25  
DTE DB-9  
Connection  
Signal  
Connection  
2
3
4
7
20  
Transmit Data (TD)  
Receive Data (RD)  
Request to Send (RTS)  
Signal Ground (SG)  
Data Terminal Ready (DTR)  
2
3
4
7
20  
3
2
7
5
4
Table 2.4 - 232SDD16 To DCE Connections  
232SDD16  
DCE DB-25 DCE DB-9  
Connection Connection  
Pin #  
Signal  
2
3
4
7
20  
Transmit Data (TD)  
Receive Data (RD)  
Request to Send (RTS)  
Signal Ground (SG)  
Data Terminal Ready  
(DTR)  
3
2
5
7
6
2
3
8
5
6
232SDD16-1005 Manual  
7
8
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3.2 - Equivalent Values  
ASCII Decimal Hexadecimal  
Chapter 3 - Commands  
There are only two commands required to control the 232SDD16:  
set output lines, and read I/O lines. Three additional commands are  
used for configuring the module: define I/O lines, set power-up  
states, and read configuration. Command strings are from four to  
six bytes in length; the “!” character, the “0” (zero) character, two  
command characters, and one or two data bytes, if required. (See  
Table 3.1).  
!
0
33  
48  
67  
68  
79  
82  
83  
21h  
30h  
43h  
44h  
4Fh  
52h  
53h  
C
D
O
R
S
Table 3.1 - 232SDD16 Commands  
Syntax  
Function  
Command  
Response  
Command strings consists of four to six bytes. The first byte is  
the start of message byte. The start of message byte is always the  
ASCII “!” character. The second byte is the address byte. This byte  
allows each unit to have a unique address (useful in RS-485  
networks). Since the 232SDD16 uses RS-232 communications, this  
byte is always the ASCII “0” character and can not be changed. The  
next two bytes are the command characters. These bytes are ASCII  
characters and used to specify which command will be executed by  
the module. Some commands require an argument field. This field  
contains the fifth and sixth data byte, a Most Significant and a Least  
Significant data byte respectively.  
Set Output Lines  
Read I/O Lines  
Define I/O Lines  
!0SO{I/O msb}{I/O lsb} no response  
!0RD  
{I/O msb}{I/O lsb}  
!0SD{I/O msb}{I/O lsb} no response  
Set Power-up States !0SS{I/O msb}{I/O lsb} no response  
I/O Definitions  
Read Configuration !0RC  
{I/O msb}{I/O lsb}  
Power-up States  
{I/O msb}{I/O msb}  
Symbols: {...} represents one byte  
<...> represents a numeric value  
Command Syntax: !  
0
|
|
|
|
_
|
|
|
|
_
|
|
_
|
|
_
|
|
|
|
|
|
|
Before going into the specifics of each command, it is important  
to understand that a byte has a numeric value from 0 to 255. The  
byte's value can be represented in decimal (0 -255) format,  
hexadecimal (00 - FF) format, binary (00000000 - 11111111) format  
or as an ASCII character. The fixed bytes of each command will be  
represented as ASCII characters, for example: “!0RD”. Refer to  
Table 3.1. However, it is important to remember that an ASCII  
character has a numeric value. Example: the ASCII “0” (zero) does  
not have a value of zero but has a value of 48. The decimal and  
hexadecimal equivalents of some ASCII characters are shown in  
Table 3.2. Some commands require additional data bytes to  
complete the command. These data bytes may be represented in  
any of the formats listed above. Refer to Appendix A for more ASCII  
and decimal equivalents.  
6th Data Byte  
|
5th Data Byte  
2nd Command Byte  
|
1stCommand Byte  
Address Byte  
Start of Message Byte  
I/O Data Bytes  
When constructing commands to manipulate outputs lines or  
when reading the state of the I/O lines it is necessary to know how  
to select and interpret the I/O data bytes. The sixteen I/O lines are  
represented by two data bytes. The Most Significant data byte  
represents I/O lines #15 through #8 and the Least Significant data  
byte represents I/O lines #7 through #0. The Most Significant byte is  
always sent and received first followed by the Least Significant byte.  
232SDD16-1005 Manual  
9
10  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A byte represents an eight-bit binary number (11111111),  
therefore each byte can represent eight I/O lines. Each bit is  
assigned a bit position and a weight (value). Refer to Table 3.3.  
Read I/O Lines Command  
The Read I/O Lines command returns two data bytes that reflect  
the state of the I/O lines. The first data byte contains the most  
significant I/O lines (15 - 8). The second data byte contains the  
least significant I/O lines (7 - 0). If a bit is a "0" then the state of that  
I/O line is LOW. If a bit is a "1" then the state of that I/O line is HIGH.  
Table 3.3 - Bit Assignments for I/O Lines  
MOST SIGNIFICANT I/O BYTE  
I/O Line #  
Bit Position  
Hex Weight  
15  
7
80  
14  
6
40  
13  
5
20  
32  
12  
4
10  
16  
11  
3
8
8
10  
2
4
4
9
1
2
2
8
0
1
1
Command: !0RD  
Argument: none  
Dec. Weight 128 64  
Response: the state of the 16 I/O lines in two 8 bit bytes (shown in  
bold face)  
ASCII Example:!0RDÈR  
Dec. Example: !0RD<200><82>  
Hex. Example: !0RD<C8><52>  
Bin. Example: !0RD<11001000><01010010>  
Description: the first byte indicates that I/O lines #15, 14, & 11 are  
HIGH and I/O lines # 13, 12, 10, 9, & 8 are LOW; the second byte  
indicates that I/O lines # 6, 4, & 1 are HIGH and I/O lines # 7, 5, 3, 2,  
& 0 are LOW.  
LEAST SIGNIFICANT I/O BYTE  
I/O Line #  
Bit Position  
Hex Weight  
7
7
80  
6
6
40  
5
5
20  
32  
4
4
10  
16  
3
3
8
8
2
2
4
4
1
1
2
2
0
0
1
1
Dec. Weight 128 64  
To set an output to a HIGH state the corresponding bit position  
must be set to a "1". Conversely to set an output LOW the  
corresponding bit position must be set to a "0". When reading I/O  
lines, any bit set to a "0" indicates the corresponding I/O line is in  
the LOW state and any bit set to a "1" indicates the corresponding  
I/O line is in the HIGH state.  
Set Output Lines Command  
The Set Output Lines command is used to set the states of the  
output lines. This command requires two data bytes. These data  
bytes specify the output state of each output line. The first data byte  
represents the most significant I/O lines (15 - 8). The second data  
byte represents the least significant I/O lines (7 - 0). If a bit position  
is set to a "0" then the state of that output line will be set LOW. If a  
bit position is set to a "1" then the state of that output line will be set  
HIGH.  
Example 3.1 - To set outputs 15, 8, 1, and 0 to a HIGH state, and all  
other outputs to a LOW state (shown in bold face) -  
MS Byte  
10000001  
129  
LS Byte  
00000011  
3
Shown in binary -  
Shown in decimal -  
(128+1)  
81  
(2+1)  
3
Shown in hexadecimal -  
(80h+1h)  
(2h+1h)  
Example 3.2 - Reply from Read I/O command (shown in bold face) -  
NOTE: Refer to the "Define I/O Lines" command to define an I/O line  
as an output.  
MS Byte  
11001000  
200  
LS Byte  
01010010  
82  
Shown in binary -  
Shown in decimal -  
(128+64+8)  
C8  
(64+16+2)  
52  
Shown in hexadecimal -  
(80h+40h+8h)  
(40h+10h+2h)  
I/O lines #15, 14, 11, 6, 4, 1 are HIGH. All other I/O lines are LOW.  
232SDD16-1005 Manual  
11  
12  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Command: !0SO  
Argument: {I/O msb}{I/O lsb}  
Set Power-up States Command  
Response: none  
ASCII Example:!0SOUA  
Dec. Example: !0SO<85><65>  
Hex. Example: !0SO <55><41>  
Bin. Example: !0SO<01010101><01000001>  
Description: the first byte sets output lines #14, 12, 10, & 8 HIGH  
and output lines #15, 13, 11, & 9 LOW; the second byte sets output  
lines #6, & 0 HIGH and output lines # 7, 5, 4, 3, 2, & 1 LOW. Note: If  
any of these lines are defined as inputs the bit settings are ignored.  
The Set Power-up States command is used to set the states of  
output lines when the module's power is recycled. This command  
requires two data bytes. These data bytes specify the output state  
of each output line. The first data byte represents the eight most  
significant I/O lines (15 - 8). The second data byte represents the  
eight least significant I/O lines (7 - 0). If a bit position is set to a "0"  
then the state of that output line will be set LOW. If a bit position is  
set to a "1" then the state of that output line will be set HIGH.  
Define I/O Lines Command  
Command: !0SS  
The Define I/O Lines command is used to define each of the 16  
I/O lines as either an input or an output. This command requires two  
data bytes. Each data byte defines eight I/O lines. The first data  
byte defines the eight most significant I/O lines (15 - 8). The second  
data byte defines the eight least significant digital I/O lines (7 - 0). If  
a bit position is set to a "0" then the I/O line will defined as an input.  
If a bit position set to a "1" then the I/O line will be defined as an  
output.  
Argument: {I/O msb}{I/O lsb}  
Response: none  
ASCII Example:!0SSÛ@  
Dec. Example: !0SS<219><64>  
Hex. Example: !0SS<DB><40>  
Bin. Example: !0SS<11011011><10000000>  
Description: the first byte sets output lines #15, 14, 12, 11, 9, & 8  
HIGH and output lines #13, & 10 LOW at power-up; the second byte  
sets output line #7 HIGH and output lines #6, 5, 4, 3, 2, 1, & 0 LOW  
at power-up. Note: If any of these lines are defined as inputs the bit  
settings are ignored.  
Command: !0SD  
Argument: {I/O msb}{I/O lsb}  
Response: none  
ASCII Example:!0SDUA  
Dec. Example: !0SD<85><65>  
Read Configuration Command  
Hex. Example: !0SD<55><41>  
The Read Configuration command returns the module's I/O  
definitions and the outputs power-up state. Four data bytes are  
returned. The first two data bytes contain the definition of the eight  
most significant I/O lines (15 - 8) and the eight least significant I/O  
lines (7 - 0) respectively. If a bit position is set to a "0" the I/O line is  
defined as an input, if set to a "1" the I/O line is defined as an output.  
The second two data bytes contain the power-up states of the most  
significant output lines (15 - 8) and the least significant output lines  
(7 - 0) respectively. If a bit position is set to a "0" the power-up state  
of the output will be LOW, if set to a "1" the output will be HIGH.  
Bin. Example: !0SD<01010101><01000001>  
Description: the first byte define I/O lines #14, 12, 10, & 8 as  
outputs and I/O lines #15, 13, 11, & 9 as inputs; the second byte  
define I/O lines #6, & 0 as outputs and I/O lines #7, 5, 4, 3, 2, & 1 as  
inputs.  
232SDD16-1005 Manual  
13  
14  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Command: !0RC  
Argument: none  
Response: definition of the sixteen I/O lines in two 8 bit bytes, and  
the power-up states in two 8 bit bytes. (shown in bold face)  
ASCII Example:!0RCUAP@  
Dec. Example: !0RC<85><65><80><64>  
Hex. Example: !0RC<55><41><50><40>  
Bin. Example: !0RC<01010101><01000001><01010000><01000000>  
Description: the first byte (MSB of I/O definitions) - I/O lines #14, 12,  
10, & 8 are outputs and I/O lines #15, 13, 11, & 9 are inputs; the  
second byte (LSB of I/O definitions) - I/O lines #6, & 0 are outputs  
and I/O lines #7, 5, 4, 3, 2, & 1 are inputs; the third byte (MSB of  
output power-up states) - output lines #14, & 12 HIGH and output  
lines #10, & 8 LOW at power-up; the fourth byte (LSB of output  
power-up states) - output line #6 HIGH and output line #0 LOW at  
power-up.  
232SDD16-1005 Manual  
15  
16  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4 - I/O Interfacing  
This chapter will explain "HIGH" and "LOW" states and show  
some general examples of how to interface to the I/O lines. Caution  
must be taken not to exceed 232SDD16 specifications listed in  
Chapter 1 when interfacing to external devices. Failure to stay  
within these specifications could result in damage to the unit and will  
void warranty.  
Digital Inputs  
As stated earlier, digital input lines are CMOS/TTL compatible  
and can only handle voltages from 0Vdc to +5Vdc.  
Figure 4.2 - Solid State Input  
Digital inputs are used to sense a HIGH or a LOW state. This  
can be accomplished via switch closures, contact closures, or a  
solid state digital signal. When an I/O line, defined as an input,  
senses a voltage level above +2.0Vdc it will be considered "HIGH"  
and its input state will be read as a "1". Conversely, when an input  
senses a voltage level below +1.0Vdc it will be considered "LOW"  
and its input state will be read as a "0".  
Inputs can also be used to sense AC voltages by using  
mechanical or solid state relays. Solid state relays are available  
from many manufacturers.  
Figures 4.1 - 4.4 show examples of some typical input interfaces.  
Figure 4.3 - Isolated Mechanical Input  
Figure 4.1 - Switch Input  
232SDD16-1005 Manual  
17  
18  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4.4 - Isolated Solid State Input  
Digital Outputs  
Figure 4.6 - Isolated Solid State Output  
Digital outputs are used to turn external devices on or off. Digital  
outputs are CMOS/TTL compatible and operate between 0Vdc and  
+5Vdc. Outputs can be used to control solid state output modules,  
CMOS and TTL logic circuits. Caution must be taken not to exceed  
the power capability of the outputs. Refer to the output  
specifications in Chapter 1.  
Setting an output line to a "1" forces the output HIGH, and setting  
an output line to a "0" forces the output LOW.  
Figures 4.5 - 4.6 show examples of some typical output  
interfaces.  
Figure 4.5 - Solid State Output  
232SDD16-1005 Manual  
19  
20  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Example 5.1 - Determining the status of I/O lines #2 & #10  
mask = &H4  
Chapter 5 - Software  
Cmnd$ = "!0RD"  
PRINT #1, Cmnd$;  
MSIO$ = INPUT$(1,#1)  
LSIO$ = INPUT$(1,#1)  
MSIO = ASC(MSIO$)  
LSIO = ASC(LSIO$)  
This chapter will be divided into two sections. The first section  
covers programming techniques for constructing a command string,  
receiving data and manipulating data in QuickBASIC. The second  
section discusses how to install and run the demonstration program  
on an IBM PC or compatible.  
MSstatus = MSIO AND mask  
LSstatus = LSIO AND mask  
Programming Techniques  
If LSstatus equals zero then I/O line #2 is LOW. If LSstatus is not  
equal to zero then I/O line #2 is HIGH. If MSstatus equals zero then  
I/O line #10 is LOW. If MSstatus is not equal to zero then I/O line  
#10 is HIGH.  
This section shows steps and examples of programming the  
232SDD16 in QuickBasic. If you are programming in another  
language, this section can be helpful as a guideline for programming  
the 232SDD16.  
Table 5.1 - Digital I/O Mask Values  
Read I/O States Command  
Step 1 - Constructing the command string:  
Cmnd$ = "!0RD"  
Mask Values  
I/O Line #  
Hexadecimal  
Decimal  
Step 2 - Transmitting the command string:  
PRINT #1, Cmnd$;  
Step 3 - Receiving the data:  
MSIO$ = INPUT$(1,#1)  
LSIO$ = INPUT$(1,#1)  
Step 4 - Manipulating the data:  
MSIO = ASC(MSIO$)  
LSIO = ASC(LSIO$)  
Step 5 - Determining an I/O's status:  
MSstatus = MSIO AND mask  
0 & 8  
1 & 9  
1H  
2H  
4H  
1
2
4
2 & 10  
3 & 11  
4 & 12  
5 & 13  
6 & 14  
7 & 15  
8H  
8
10H  
20H  
40H  
80H  
16  
32  
64  
128  
Read Configuration Command  
Step 1 - Constructing the command string:  
Cmnd$ = "!0RC"  
Step 2 - Transmitting the command string:  
PRINT #1, Cmnd$;  
Step 3 - Receiving the data:  
MSdefs$ = INPUT$(1,#1)  
LSdefs$ = INPUT$(1,#1)  
LSstatus = LSIO AND mask  
By "ANDing" the value of MSIO or LSIO with the appropriate  
mask of an I/O line, the status of the I/O line can be determined.  
If the status is equal to zero the I/O line is LOW. If the status is  
not equal to zero the I/O line is HIGH. Table 5.1 shows the mask  
values for each I/O line.  
Step 6 - Repeat Step 5 until the status of each I/O line has been  
determined.  
MSpups$ = INPUT$(1,#1)  
LSpups$ = INPUT$(1,#1)  
Step 4 - Manipulating the data:  
MSdefs = ASC(MSdefs$)  
LSdefs = ASC(LSdefs$)  
MSpups = ASC(MSpups$)  
LSpups = ASC(LSpups$)  
232SDD16-1005 Manual  
21  
22  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 5 - Determining the I/O line definitions:  
MSdefs = MSdefs AND mask  
If LSdefs equals zero then I/O line #2 is an INPUT and if not equal  
to zero then I/O line #2 is an OUTPUT. If MSdefs equals zero then  
I/O line #10 is an INPUT and if not equal to zero then I/O line #10 is  
an OUTPUT. If LSpups equals zero then Output line #2's power-up  
state is LOW and if not equal to zero then Output line #2's power-up  
state is HIGH. If MSpups equals zero then Output line #10's power-  
up state is LOW and if not equal to zero then Output line #10's  
power-up state is HIGH.  
LSdefs = LSdefs AND mask  
By "ANDing" the value of MSdefs or LSdefs with the appropriate  
mask of an I/O line, the I/O line definition can be determined. If  
the status is equal to zero the I/O line is an INPUT. If the status is  
not equal to zero the I/O line is an OUTPUT. Table 5.1 shows  
the mask values for each I/O line.  
Step 6 - Repeat Step 5 until the status of each I/O line has been  
determined.  
Set Output States Command  
Step 7 - Determining an OUTPUT's Power-up state:  
MSpups = MSpups AND mask  
Step 1a - Construct the command string:  
Set appropriate outputs HIGH  
LSpups = LSpups AND mask  
MSstates = MSstates OR mask  
By "ANDing" the value of MSpups or LSpups with the  
appropriate mask of an Output line, the Output line definition can  
be determined. If the status is equal to zero the Output power-up  
state will be LOW. If the status is not equal to zero the Output  
power-up state will be HIGH. Table 5.1 shows the mask values  
for each I/O line.  
LSstates = LSstates OR mask  
By "ORing" the current states with the appropriate mask of a  
digital output line, the output's bit will be set to a "1" (HIGH).  
Step 1b - Set appropriate outputs LOW  
MSstates = MSstates AND (NOT(mask))  
LSstates = LSstates AND (NOT(mask))  
By "ANDing" the current states with the complement of the  
appropriate mask of a digital output line, the output's bit will be  
set to a "0" (LOW).  
Step 8 - Repeat Step 7 until the power-up state of each Output line  
has been determined.  
Example 5.2 - Determining the definition and power-up state of I/O  
lines #2 & #10  
Step 1c - Completing the command string:  
Cmnd$ = "!0SO" + CHR$(MSstates) + CHR$(LSstates)  
Step 2 - Transmitting the command string:  
Print #1, Cmnd$;  
mask = &H4  
Cmnd$ = "!0RC"  
PRINT #1, Cmnd$;  
MSdefs$ = INPUT$(1,#1)  
LSdefs$ = INPUT$(1,#1)  
MSpups$ = INPUT$(1,#1)  
LSpups$ = INPUT$(1,#1)  
MSdefs = ASC(MSdefs$)  
LSdefs = ASC(LSdefs$)  
MSpups = ASC(MSpups$)  
LSpups = ASC(LSpups$)  
MSdefs = MSdefs AND mask  
LSdefs = LSdefs AND mask  
MSpups = MSpups AND mask  
LSpups = LSpups AND mask  
Example 5.3 - Set Output #0 HIGH and Output #14 LOW.  
'Set bit 0 of LSstates to make Output #0 HIGH.  
LSstates = LSstates OR &H1  
'Clear bit 4 of MSstates to make Output #14 LOW.  
MSstates = MSstates AND (NOT(&H40))  
Cmnd$ = "!0SO" + CHR$(MSstates) + CHR$(LSstates)  
PRINT #1, Cmnd$;  
MSIO$ = INPUT$(1,#1)  
Output #0 will be set HIGH and output #14 will be set LOW. All  
other output setting will not be changed.  
232SDD16-1005 Manual  
23  
24  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Define I/O Lines Command  
Step 1a - Construct the command string:  
Define an I/O line as Output  
Step 1b - Set appropriate outputs power-up states LOW  
MSpups = MSpups AND (NOT(mask))  
LSpups = LSpups AND (NOT(mask))  
MSdefs = MSdefs OR mask  
LSdefs = LSdefs OR mask  
By "ORing" the current definitions with the appropriate I/O line  
mask, the I/O line's data bit will be set to a "1" (HIGH) and the I/O  
line will be defined as an Output.  
By "ANDing" the current power-up states with the complement of  
the appropriate mask of a digital output line, the power-up state's  
data bit will be set to a "0" (LOW).  
Step 1c - Completing the command string:  
Cmnd$ = "!0SS" + CHR$(MSpups) + CHR$(LSpups)  
Step 2 - Transmitting the command string:  
Print #1, Cmnd$;  
Step 1b - Define an I/O line as an Input  
MSdefs = MSdefs AND (NOT(mask))  
LSdefs = LSdefs AND (NOT(mask))  
By "ANDing" the current definitions with the complement of the  
appropriate I/O line mask the I/O line's data bit will be set to a "0"  
(LOW) and the I/O line will be defined as an Input.  
Step 1c - Completing the command string:  
Cmnd$ = "!0SD" + CHR$(MSdefs) + CHR$(LSdefs)  
Step 2 - Transmitting the command string:  
Print #1, Cmnd$;  
Example 5.5 - Set Output line #5's power-up state HIGH and Output  
line #13's power-up state LOW.  
'Set bit 0 of LSpups to make Output #5's power-up state HIGH.  
LSpups = LSpups OR &H20  
'Clear bit 4 of MSpups to make Output #13's power-up state LOW.  
MSpups = MSpups AND (NOT(&H20))  
Cmnd$ = "!0SS" + CHR$(MSpups) + CHR$(LSpups)  
Print #1, Cmnd$;  
Example 5.4 - Define I/O line #7 as an Output (HIGH) and I/O line #8  
as an input (LOW).  
'Set bit 7 of LSdefs to make I/O line #7 an Output (HIGH).  
LSdefs = LSdefs OR &H80  
MSIO$ = INPUT$(1,#1)  
Output #5's power-up state will be set HIGH and output #13's  
power-up state will be set LOW. All other output power-up states  
will not be changed.  
'Clear bit 0 of MSdefs to make I/O line #8 an Input (LOW).  
MSdefs = MSdefs AND (NOT(&H1))  
Cmnd$ = "!0SD" + CHR$(MSdefs) + CHR$(LSdefs)  
Print #1, Cmnd$;  
MSIO$ = INPUT$(1,#1)  
I/O #7 will be defined as an Output (HIGH) and I/O line #8 will be  
defined as an Input (LOW). All other I/O definitions will not be  
changed.  
Set Power-up States Command  
Step 1a - Construct the command string:  
Set appropriate outputs power-up states HIGH  
MSpups = MSpups OR mask  
LSpups = LSpups OR mask  
By "ORing" the current power-up states with the appropriate  
mask of a digital output line, the power-up state's data bit will be  
set to a "1" (HIGH).  
232SDD16-1005 Manual  
25  
26  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Demonstration Program  
The 232SDD16 Demonstration (SDD16) Program (IBM PC or  
Compatible) provides the user with examples of how to receive and  
transmit commands to the 232SDD16. The SDD16.EXE is the  
executable program, the SDD16.BAS file is the source code in  
QuickBASIC. The source code provides an illustration of how to  
send and receive commands from the 232SDD16.  
NOTE: This is a demonstration program only and not intended for  
system applications.  
Running Demonstration Program  
Before you can run the demonstration program you must run the  
install program in the Hard Drive Installation section. If you are  
running Windows, exit Windows to DOS.  
To run the program follow these steps from the DOS prompt:  
1.  
2.  
Type CD \232SDD16 and press the <Enter> key.  
Type SDD16 and press the <Enter> key.  
232SDD16-1005 Manual  
27  
28  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DECIMAL to HEX to ASCII CONVERSION TABLE  
DEC HEX ASCII KEY DEC HEX ASCII DEC HEX ASCII DEC HEX ASCII  
0
1
NUL ctrl @ 32  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
2A  
2B  
2C  
2D  
2E  
2F  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
3A  
3B  
3C  
3D  
3E  
3F  
SP  
!
64  
65  
66  
67  
68  
69  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
4A  
4B  
4C  
4D  
4E  
4F  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
5A  
5B  
5C  
5D  
5E  
5F  
@
A
B
C
D
E
F
G
H
I
96  
60  
61  
62  
63  
64  
65  
66  
67  
68  
69  
6A  
6B  
6C  
6D  
6E  
6F  
70  
71  
72  
73  
74  
75  
76  
77  
78  
79  
7A  
7B  
7C  
7D  
7E  
7F  
`
a
b
c
d
e
f
0
1
SOH  
STX  
ETX  
EOT  
ENQ  
ACK  
BEL  
BS  
ctrl A  
ctrl B  
ctrl C  
ctrl D  
ctrl E  
ctrl F  
ctrl G  
ctrl H  
ctrl I  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
97  
2
2
98  
3
3
#
$
%
&
'
99  
4
4
100  
101  
102  
103  
104  
105  
106  
107  
108  
109  
110  
111  
112  
113  
114  
115  
116  
117  
118  
119  
120  
121  
122  
123  
124  
125  
126  
127  
5
5
6
6
7
7
g
h
i
8
8
(
9
9
HT  
)
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
A
LF  
ctrl J  
ctrl K  
ctrl L  
ctrl M  
ctrl N  
ctrl O  
ctrl P  
ctrl Q  
ctrl R  
ctrl S  
ctrl T  
ctrl U  
ctrl V  
*
J
j
B
VT  
+
,
K
L
k
l
C
FF  
D
CR  
-
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
m
n
o
p
q
r
E
SO  
.
F
SI  
/
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
1A  
1B  
1C  
1D  
1E  
1F  
DLE  
DC1  
DC2  
DC3  
DC4  
NAK  
SYN  
0
1
2
3
4
5
6
7
8
9
:
APPENDIX A  
ASCII Character Codes  
s
t
u
v
w
x
y
z
{
ETB ctrl W  
CAN  
EM  
ctrl X  
ctrl Y  
ctrl Z  
ctrl [  
SUB  
ESC  
FS  
;
ctrl \  
<
=
>
?
\
|
GS  
ctrl ]  
]
}
RS  
ctrl ^  
ctrl _  
^
~
DEL  
US  
_
232SDD16-1005 Manual  
Appendix A  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
A-1  
A-2  
Appendix A  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The decimal (base 10) numbering system represents each  
position in successive powers of 10, with each decimal symbol  
having a value from 0 to 9. The hexadecimal (base 16) numbering  
system represents each position in successive powers of 16 with  
each hex symbol having a value of 0 to 15. Since each hex position  
must have a single symbol, the symbols "A" through "F" are  
assigned to values 10 through 15 respectively. Refer to Table 1.  
The information and examples to follow will explain how to convert  
from a decimal number to a hexadecimal number and vice versa.  
Table 1.  
Decimal  
Hexadecimal  
Value  
Symbol  
0
1
0
1
2
2
3
3
4
4
5
5
6
6
7
7
8
9
8
9
APPENDIX B  
Hexadecimal/Decimal Conversions  
10  
11  
12  
13  
14  
15  
A
B
C
D
E
F
232SDD16-1005 Manual  
Appendix B  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B-1  
B-2  
Appendix B  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hexadecimal to Decimal Conversion:  
Decimal = (1st Hex digit x 4096) +  
(2nd Hex digit x 256) +  
(3rd Hex digit x 16) +  
(4th Hex digit)  
Each "Hex digit" is the decimal equivalent value of the  
hexadecimal symbol.  
Example: Convert 10FC hexadecimal to decimal.  
1
0
15  
12  
x
x
x
x
4096  
256  
16  
=
=
=
=
4096  
0
240  
12  
1
4348  
10FC hex equals 4348 decimal.  
Decimal to Hexadecimal Conversion:  
Example: Convert 4348 decimal to hexadecimal.  
4096 4348  
4096  
=
=
=
=
1
0
=
=
=
=
1
0
(1st Hex digit)  
(2nd Hex digit)  
(3rd Hex digit)  
(4th Hex digit)  
256  
16  
1
252  
0
252  
240  
12  
12  
0
15  
12  
F
C
4348 decimal equals 10FC hexadecimal.  
232SDD16-1005 Manual  
Appendix B  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B-3  
B-4  
Appendix B  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DTB25  
The DTB25 connects to the SDD16 models to provide easy  
access to the available I/O lines. The DTB25 plugs directly into the  
SDD16's DB25S I/O Port connector. Each of the twenty-five pins on  
the connector is brought out to a terminal block. Refer to Table C.1.  
Dimensions: 0.5" x 2.1" x 4.3". An enclosure for the DTB25 is  
available.  
APPENDIX C  
Interface Modules for SDD16 Models  
Figure C.1 - DTB25 Outline Drawing  
Before connecting any external devices to the DTB25 make sure  
the SDD16 module has been properly configured (I/O lines defined,  
power-up states set). This will avoid possible damage to the module  
and to the external devices. Make sure not to exceed the voltage  
and current limits of the SDD16 module, failure to do so could result  
in damage to the module and will void the warranty. Refer to the  
Specification Section of this Manual.  
232SDD16-1005 Manual  
Appendix C  
C-1  
C-2  
Appendix C  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table C.1 - DTB25 Connections  
DBM16  
DB-25P  
Pin #  
T.B. DB-25P  
T.B.  
#
The DBM16 module provides buffering and increased power  
Function  
Unused.  
#
Pin #  
Function  
I/O #15  
handling for all the sixteen I/O lines of the SDD16 models. Each of  
the I/O lines can be programmed as an input or as an output by  
setting a jumper on the board. The DBM16  
plugs directly into the SDD16's DB25S I/O Port connector.  
Terminal blocks are provided for all I/O line, power, and ground  
connections. Refer to Table C.2. An enclosure for the DBM16 is  
available.  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
Unused.  
Unused.  
Unused.  
Unused.  
Unused.  
Ground  
+12Vdc Input  
I/O #0  
I/O #1  
I/O #2  
I/O #3  
I/O #4  
I/O #14  
I/O #13  
I/O #12  
I/O #11  
I/O #10  
Unused.  
I/O #9  
I/O #8  
I/O #7  
I/O #6  
I/O #5  
Table C.2 - DBM16 I/O Connections  
T.B.1  
Label  
T.B.2  
Label  
Function  
Function  
I/O7 I/O Line #7  
GND Ground  
I/O8 I/O Line #8  
GND Ground  
I/O6 I/O Line #6  
I/O5 I/O Line #5  
GND Ground  
I/O9 I/O Line #9  
I/O10 I/O Line #10  
GND Ground  
I/O4 I/O LIne #4  
I/O3 I/O Line #3  
GND Ground  
I/O11 I/O LIne #11  
I/O12 I/O Line #12  
GND Ground  
I/O2 I/O LIne #2  
I/O1 I/O Line #1  
GND Ground  
I/O13 I/O LIne #13  
I/O14 I/O Line #14  
GND Ground  
I/O0 I/O LIne #0  
GND Ground  
I/O15 I/O LIne #15  
+12 +12Vdc Input  
ITS Inductive-load  
Transient  
Suppression  
232SDD16-1005 Manual  
Appendix C  
C-3  
C-4  
Appendix C  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DBM16 Interfacing  
This section will show some general examples of how to  
interface the DBM16 I/O lines to external devices. Caution must be  
taken not to exceed the DBM16 specifications, failure to do so could  
result in damage to the DBM16 and will void the warranty.  
Before connecting the DBM16 to the SDD16 module and  
connecting any external device to the DBM16 determine which I/O  
lines on the SDD16 module are inputs and which are outputs. Once  
the inputs and outputs are known, set the jumpers on the DBM16  
accordingly. Refer to Figure C.2.  
Figure C.3 - Switch Input  
Figure C.2 - DBM16 Outline Drawing  
Figure C.4 - Solid State Input  
Inputs  
Digital inputs are used to sense "HIGH" and "LOW" states based  
on voltage levels. This is accomplished via switch closures, contact  
closures or a solid state digital signals. Each DBM16 input is pulled  
up through a resistor and will be read as a logic "1" (HIGH) by the  
SDD16 module. When an input on the DBM16 is grounded (below  
+1.5Vdc), a logic "0" (LOW) will be read by the SDD16 module.  
Figures C.3 - C.6 show examples of some typical input interfaces.  
Figure C.5 - Isolated Mechanical Input  
232SDD16-1005 Manual  
Appendix C  
C-5  
C-6  
Appendix C  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure C.6 - Isolated Solid State Input  
Figure C.8 - Isolated Mechanical Output  
Outputs  
Digital outputs are used to turn "ON" or turn "OFF" external  
devices. Outputs can be used to control solid state output modules,  
logic circuits, and relays. Caution must be taken not to exceed the  
power capability of the outputs. Refer to the DBM16 output  
specifications.  
Setting the SDD16 module's output line to a "1" turns "ON" the  
DBM16's output line. Setting the SDD16 module's output line to a  
"0" turns "OFF" the DBM16's output driver. The DBM16 outputs are  
open collector current sinking drivers. Figures C.7 - C.9 show  
examples of some typical output interfaces.  
Figure C.9 - Isolated Solid State Output  
Figure C.7 - Solid State Output  
232SDD16-1005 Manual  
Appendix C  
C-7  
C-8  
Appendix C  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DBM16 Specifications  
I/O Lines  
Total:  
16 (Factory default - set to inputs)  
Inputs  
Voltage range:  
Low Voltage:  
High Voltage:  
Internal pull-up current:  
Outputs  
0Vdc to +50Vdc  
0Vdc to +1.5Vdc  
+2.5Vdc to +50Vdc  
0.5 ma  
Output Voltage:  
Output current:  
+50Vdc max.  
350 ma max. - only 1 output on  
100 ma max. - all outputs on  
50 micro amp max.  
Output leakage current:  
Output saturation voltage: 1.1Vdc max. @ 100ma  
CAUTION: Total output power cannot exceed 2 watts for I/O's #0-  
7 and 2 watts for I/O #8-15 @ 25 degrees C.  
Power Supply  
Input Voltage:  
8Vdc to 16Vdc @ 10milliamps  
(Doesn't include the power  
consumption of external devices.)  
Terminal Blocks  
Connections:  
Size  
0.5" x 2.1" x 4.5"  
Figure C.10 - DBM16 Schematic  
232SDD16-1005 Manual  
Appendix C  
C-9  
C-10  
Appendix C  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
232SDD16-1005 Manual  
Appendix C  
C-11  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
With serial communications in a laboratory environment, the  
possibility of a communication error occurring is minimal. However,  
in a harsh or an industrial environment the possibility increases. A  
communication error occurs when a bit transmitted as a “1” is  
received as a “0” or vice versa. If the 232SDD16 receives a error in  
one or more of the first four command characters (“!0xx”), the unit  
will not execute the command. However, if the 232SDD16 receives  
an communication error on a data byte (I/O byte for Read Digital  
command or state byte for Set Output State command), the  
command will be executed since the unit has no way of knowing that  
there was an error.  
To provide the 232SDD16 with a way of detecting errors in the  
data fields, an additional set of commands can be used. This set of  
commands begins with the “#” (23h) character, instead of the “!”  
(21h) character. Refer to Table D-1. With these commands every  
data byte that is transmitted or received is followed by it’s  
complement. For example: To read I/O lines:  
Command syntax:  
#0RD  
Response syntax:  
{I/O msb}{~ I/O msb}{I/O lsb} {~ I/O lsb}  
Where “~” is used to indicate the “complement of.” If I/O has a  
reading of 1, the following would be received:  
Appendix D  
Adding Data Field Confirmation  
{00}{FF}{01}{FE}  
Where FFh is the complement of 0 and FEh is the complement of  
1. The complement of number “x” can be calculated in QuickBasic  
as follows:  
comp = (NOT x) AND &HFF  
232SDD16-1005 Manual  
Appendix D  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
D-1  
D-2  
Appendix D  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table D-1 Extended Commands  
Function  
Command  
Response  
Read I/O Lines  
#0RD  
{I/O msb}{~I/O msb}{I/O  
lsb}{~I/O lsb}  
Set Output Lines  
Define I/O Lines  
#0SO{I/O  
msb}{~I/O  
msb}{I/O  
lsb}{~I/O lsb}  
#0SD{I/O  
msb}{~I/O  
msb}{I/O  
msb}{~I/O msb}  
#0SS{I/O  
msb}{~I/O  
msb}{I/O  
no response  
no response  
no response  
Set Power-up  
States  
lsb}{~I/O lsb}  
Read  
Configuration  
#0RC  
{I/O msb}{~I/O msb}{I/O  
lsb}{~I/O lsb}{I/O powerup  
msb states}{~I/O powerup  
msb states}{I/O powerup  
lsb states}{~I/O powerup  
lsb}  
Where “x” is the required data byte and “~” signifies the complement  
of the specified byte.  
232SDD16-1005 Manual  
Appendix D  
D-3  
D-4  
Appendix D  
232SDD16-1005 Manual  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350  
PH (815) 433-5100 -- FAX (815) 433-5104  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Switch 4210 18 PORT User Manual
Acer Projector P1165E User Manual
Advanced Global Technology Digital Camera QSP 660 User Manual
AEG Dishwasher 34350 I User Manual
AG Neovo Flat Panel Television H 17 User Manual
Airlink101 Network Card AWLL4030 User Manual
Alto Shaam Food Warmer 500 E Deluxe User Manual
Audiovox Car Stereo System ACD95 User Manual
Avital Automobile Alarm 2300 User Manual
BeefEater Gas Grill Gas Barbecues User Manual