| USB Extender   Model UEC100M/4   707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA   Phone (815) 433-5100 -- General Fax (815) 433-5105   Phone (815) 433-5100 -- General Fax (815) 433-5105   Website: www.bb-elec.com   European Headquarters   B&B Electronics   Westlink Commercial Park -- Oranmore, Co. Galway, Ireland   Phone +353 91-792444 -- Fax +353 91-792445   Website: www.bb-europe.com   B&B Electronics Mfg. Co. Inc. -- June 2005   Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Table of Contents   INTRODUCTION ...........................................................................................1   ULINX EXTENDER PRODUCT CONTENTS .....................................................1   ABOUT THE ULINX EXTENDER....................................................................2   BEFORE YOU BEGIN....................................................................................5   INSTALLING THE LOCAL UNIT.....................................................................5   INSTALLING THE REMOTE UNIT ..................................................................5   CONNECTING THE LOCAL UNIT TO THE REMOTE UNIT ...............................6   CHECKING THE INSTALLATION....................................................................6   CONNECTING A USB DEVICE......................................................................7   TROUBLESHOOTING ....................................................................................8   SPECIFICATIONS ........................................................................................11   CONTACTING TECHNICAL SUPPORT ..........................................................12   Manual Documentation Number: UEC100M/4-2305   i ii   Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Introduction   About the Ulinx Extender   This manual is intended to assist IT professionals install the Ulinx Extender   model . The instructions in this guide assume a general knowledge of   computer installation procedures, familiarity with cabling requirements,   and some understanding of USB devices.   The Ulinx Extender breaks the five-meter distance barrier for the   connection of USB peripheral devices and allows users to enjoy the   benefits of USB technology beyond the desktop. With the Ulinx Extender,   USB devices can be located up to 100 meters from the host computer. In   addition, the Ulinx Extender can supply power to remote low-power or   high-power USB devices.   NOTE: Notes give additional information that could make installation   easier.   The Ulinx Extender is composed of two individual units, the Local Unit   and the Remote Unit.   Ulinx Extender Product Contents   When you open your Ulinx Extender for the first time you should find the   following items:   The Local Unit   The Local Unit connects to the host computer using a conventional   USB cable. Depending on your needs, it also connects to a power   outlet through an AC power adapter.   • Ulinx Extender User Guide   • Local Unit   • Remote Unit   • AC power adapter   Front View   • USB cable (2m long)   To complete the installation, you will also require the following items that   are not included with the product:   3 1 5 • USB compatible computer   • USB device   6 • Category 5 Unshielded Twisted Pair (UTP) cable with two RJ45   connectors (if using surface cabling),   OR,   2 4 Category 5 UTP cabling with two information outlets and two   Category 5 UTP patch cords with RJ45 connectors (if using   premise cabling)   1 Host LED   4 Link Port (RJ45)   5 Power LED   NOTE: The maximum length of the Category 5 UTP cable, including   2 Host Port (USB Type B)   3 Link LED   patch cords, must not exceed 100m.   6 Power connector   NOTE: The power adapter for the Ulinx Extender can be connected to   either the Local Unit or to the Remote Unit, as convenient. With   the Ulinx Extender UEC100M/4, the location of the power adapter   also depends on whether you are connecting high-power or low-   power USB devices. (See Power Handling on page 4).   Manual Documentation Number: UEC100M/4-2305   1 2 Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   USB Cables   The Remote Unit   USB cables have two distinct connectors. The Type A connector is used to   connect the cable from a USB device to the Type A port on a computer or   hub. The Type B connector is used to attach the USB cable to a USB   device.   The Remote Unit connects to the USB device using a conventional   USB cable. Depending on your needs, it also connects to a power   outlet through an AC power adapter. The Remote Unit of the   UEC100M/4 allows you to connect up to four USB devices.   Front View   Rear View   5 1 3 USB Type A   port   USB Type B   port   USB Type B   connector   USB Type A   connector   4 Power Handling   Some USB devices are powered directly from the USB and do not require   individual power supplies. These devices are called bus-powered devices.   The Ulinx Extender can provide power to these devices so they can be   operated remotely.   2 6 1 Link LED   5 Device LED(s)   Bus-powered devices are further divided into low-power and high-power   categories. Low-power devices are allowed to draw up to 100 mA from the   USB. Typical examples include mice, joysticks, and keyboards without   hubs. High-power devices are allowed to draw up to 500 mA from the   USB. Typical examples include cameras and keyboards with hubs. To   determine if a device is high-power or low-power, consult the user   documentation for the device.   2 Link Port (RJ45)   3 Power LED   6 Device Port(s) (USB Type   A)   4 Power connector   Network Cabling   The Ulinx Extender UEC100M/4 can supply power to both low-power and   high-power devices when configured as follows:   The Local Unit and Remote Unit are interconnected by up to 100   meters of Category 5 Unshielded Twisted Pair (UTP) cabling. The   UTP cabling must have a straight-through conductor configuration,   with no crossovers, and must be terminated with 8-conductor RJ45   connectors at both ends.   • To operate up to four low-power devices, connect the   power adapter to the Local Unit or the Remote Unit, as   convenient.   • To operate up to four high-power devices, connect the   power adapter to the Remote Unit.   Local   Unit   Remote   Unit   NOTE: Devices with their own power source are usually considered to be   USB   USB   Category 5 cable   AC power adapter   low-power devices from a USB perspective.   cable   cable(s)   computer   USB   device(s)   Compatibility   The Ulinx Extender complies with USB 1.1 specifications governing the   design of full speed USB devices. However, B&B Electronics does not   guarantee that all full speed USB devices are compatible with the Ulinx   Extender UEC100M/4.   NOTE:Category 5 UTP cabling is the standard data communications   cable installed in most commercial and some residential buildings.   Manual Documentation Number: UEC100M/4-2305   3 4 Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Before You Begin   Before you can install the Ulinx Extender, you need to prepare your site.   Connecting the Local Unit to the Remote Unit   1. Determine where the host computer is to be located and set up the   computer.   NOTE:To ensure proper operation, we recommend that only Category 5   or better, Unshielded Twisted Pair (UTP) cabling be used to   connect the Local Unit to the Remote Unit. The UTP cabling must   have a straight-through conductor configuration with no   crossovers, and must be terminated with 8-conductor RJ45   connectors at both ends.   2. Determine where you want to locate the USB device(s).   3. Decide whether the power adapter is to be connected to the Local   Unit or the Remote Unit (see the discussion of power handling on   page 4).   4. If you are using surface cabling, ensure you have enough Category   5 UTP cabling to connect the two locations.   With Surface Cabling   OR   1. Plug one end of the Category 5 UTP cabling (not included) into the   Link port on the Local Unit.   If you are using premise cabling, ensure Category 5 UTP cabling   is installed between the two locations, with Category 5   information outlets located near both the computer and the USB   device.   2. Plug the other end of the Category 5 UTP cabling into the Link port   on the Remote Unit.   With Premise Cabling   Installing the Local Unit   1. Plug one end of a Category 5 patch cord (not included) into the Link   port on the Local Unit.   1. Place the Local Unit near the host computer.   2. If the power adapter is to be located with the Local Unit:   a) Plug the power adapter into a suitable AC outlet.   b) Connect the power adapter to the Local Unit.   2. Plug the other end of the patch cord into the Category 5 information   outlet near the host computer.   3. Plug one end of the second Category 5 patch cord (not included)   into the Link port on the Remote Unit.   3. Plug the Type B connector on the USB cable (included) into the   Host port on the Local Unit.   4. Plug the other end of the second patch cord into the Category 5   information outlet near the USB device.   4. Plug the Type A connector on the USB cable into the USB port on   the computer.   NOTE: The maximum length of the Category 5 UTP cable, including   patch cords, must not exceed 100 meters.   Installing the Remote Unit   Checking the Installation   1. Place the Remote Unit near the USB device(s).   2. If the power adapter is to be located with the Remote Unit:   a) Plug the power adapter into a suitable AC outlet.   b) Connect the power adapter to the Remote Unit.   1. Check that the Power LEDs on the Local Unit and Remote Unit   are both on.   2. Check that the Link LEDs on the Local Unit and Remote Unit are   both on.   3. Check that the Host LED on the Local Unit is on.   4. On the host PC, open the Device Manager applet. Expand the   entry for Universal Serial Bus controllers by clicking the + sign. If   the Ulinx Extender has been installed correctly you should find it   listed as a Generic USB Hub.   Manual Documentation Number: UEC100M/4-2305   5 6 Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Connecting a USB Device   Troubleshooting   1. Install any software required to operate the USB device(s). Refer   to the documentation for the device(s), as required.   The following table provides troubleshooting help. The topics are arranged   in the order in which they should be executed in most situations. If you are   unable to resolve the problem after following these instructions, please   contact technical support for further assistance (see page 12).   2. Connect the USB device to the Device port on the Remote Unit.   3. Check that the Device LED on the Remote Unit is on.   Symptoms/Cause   Remedy   All LEDs on Local Unit and   Remote Unit are off.   1. Ensure that the power adapter is connected to   the Local Unit or Remote Unit   Cause:   2. Check that the adapter is connected to a live   source of electrical power   The Ulinx Extender is not   receiving power from the   adapter   Power LED on one unit is   on, power LED on other unit   is off.   1. Ensure that a Category 5 UTP cable with   straight-through conductors is connected   between the Local Unit and Remote Unit.   Cause:   2. Connect a short Category 5 patch cord   between the Local Unit and Remote Unit.   Recheck the operation of the system.   There is no connection   between the Local Unit and   Remote Unit.   Link LEDs on Local Unit   and Remote Unit are off.   3. Ensure that a Category 5 UTP cable with   straight-through conductors is connected   between the Local Unit and Remote Unit.   Cause:   There is no connection   between the Local Unit and   Remote Unit.   4. Connect a short Category 5 patch cord   between the Local Unit and Remote Unit.   Recheck the operation of the system.   USB Hub Power   Exceeded message is   displayed by the computer.   5. Move the power adapter from the Local Unit to   the Remote Unit.   Cause:   The USB device connected   to the Remote Unit is a   high-power device and the   power adapter is connected   to the Local Unit   Manual Documentation Number: UEC100M/4-2305   7 8 Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Symptoms/Cause   Remedy   Symptoms/Cause   Remedy   Link LED on Local Unit is   1. Disconnect all USB devices from the Remote   Unit.   on;   All LEDs on both the Local   Unit and Remote Unit are   on but the device does not   operate correctly   1. Disconnect the Ulinx Extender from the   computer.   Host LED on Local Unit is   off.   2. Disconnect the Local Unit from the computer.   2. Connect the USB device directly to the USB   port on the computer.   3. Disconnect and then reconnect the power   adapter to the Ulinx Extender.   Cause:   Cause:   a) The computer is not   functioning.   3. If the device does not operate properly,   consult the user documentation for the device.   4. Reconnect the Local Unit to the computer.   a) The USB device is   malfunctioning.   5. In the Universal Serial Bus controllers section   of Device Manager, check that the Ulinx   Extender is recognised as a “Generic USB   Hub”.   b) The Local Unit is not   connected to the   computer.   4. If the device operates properly when directly   connected to the computer, connect another   device (of a different type) to the Ulinx   Extender. Connect the Ulinx Extender to the   computer.   b) The computer does not   recognise the USB   device.   c) The computer does not   support USB hubs.   6. If the Ulinx Extender is not recognised, contact   technical support for assistance.   c) The application software   for the device is not   operating.   5. If the second device does not operate, the   Ulinx Extender may be malfunctioning.   Contact technical support for assistance.   d) The Ulinx Extender is   malfunctioning.   d) The Ulinx Extender is   malfunctioning.   A device is connected to   Remote Unit and the   corresponding Device LED   is off   1. Disconnect the Ulinx Extender from the   computer.   6. If the second device does operate properly,   the first device may not be compatible with the   Ulinx Extender. Contact technical support for   assistance.   2. Connect the USB device directly to the USB   port on the computer.   Cause:   3. If the device does not operate properly,   consult the user documentation for the device.   a) The USB device is   malfunctioning.   4. If the device operates properly when directly   connected to the computer, connect another   device (of a different type) to the Ulinx   Extender. Connect the Ulinx Extender to the   computer.   b) The computer does not   recognise the USB   device.   c) The application software   for the device is not   operating.   5. If the second device does not operate, the   Ulinx Extender may be malfunctioning.   Contact technical support for assistance.   d) The Ulinx Extender is   malfunctioning.   6. If the second device does operate properly,   the first device may not be compatible with the   Ulinx Extender. Contact technical support for   assistance.   Manual Documentation Number: UEC100M/4-2305   9 10   Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   Specifications   Contacting Technical Support   If you require technical assistance, send an e-mail message to:   To help us serve you better, please include the following information with   your technical support request:   Range (over Category   5 UTP cable)   100 meters (330 ft)   USB device support   Full speed devices (12 Mb/s)   Low speed devices (1.5 Mb/s)   USB hub support   Any single chain can include four USB hubs and   one Ulinx Extender UEC100M/4, in any order.   • Description of the problem   • Host computer make and model   Power available to USB 4 x 100 mA (when powered at Local Unit)   • Type of operating system installed (e.g. Win98, Mac OS X, etc.)   • Part number and serial number of the Local Unit and the Remote   Unit   device at Remote Unit   (Ulinx Extender   UEC100M/4)   4 x 500 mA (when powered at Remote Unit)   • Make and model of any USB device attached to the Ulinx Extender   • Description of the installation   USB cable   2 meters (6.6 ft)   1 x USB Type B   Local Unit connector   (upstream)   Local Unit connector   (downstream)   1 x RJ45   Remote Unit connector 1 x RJ45   (upstream)   Remote Unit connector 4 x USB Type A   (downstream)   Local Unit dimensions   10.7 x 8.4 x 3.4 cm   4.3 x 3.4 x 1.4 in   Local Unit weight   0.3 kg (0.6 lb)   Remote Unit   dimensions   10.7 x 8.4 x 3.4 cm   4.3 x 3.4 x 1.4 in   Remote Unit weight   0.3 kg (0.6 lb)   1.1 kg (2.4 lb)   Total system shipping   weight   Temperature range   Regulatory testing   4°C to 40°C   FCC, CE Class A   Manual Documentation Number: UEC100M/4-2305   11   12   Manual Documentation Number: UEC100M/4-2305   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com   B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com   Download from Www.Somanuals.com. All Manuals Search And Download.   |