Ayre Acoustics Stereo Amplifier V 6x User Manual

Ayre V-6x  
Owner’s Manual  
A y r e  
V-6x  
Power Amplifier  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of  
Contents  
Welcome to  
Ayre . . . . . . . . . . . . . . . . . . . . . . . 2  
Installation . . . . . . . . . . . . . . . . . . . . 3  
Operation. . . . . . . . . . . . . . . . . . . . . 7  
Specifications . . . . . . . . . . . . . . . . . . 10  
Trouble . . . . . . . . . . . . . . . . . . . . . 11  
Warranty . . . . . . . . . . . . . . . . . . . . 14  
Notes . . . . . . . . . . . . . . . . . . . . . . 17  
Connections and  
Controls and  
Numbers and  
In Case of  
Statement of  
A Place for  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Welcome to  
Ayre  
Please send in your warranty  
registration card so we can  
stay in contact with you.  
Your Ayre V-6x offers a significant advance in the  
musical performance of high-fidelity equipment.  
The warmth and immediacy of a live performance  
are apparent from the first listening. The  
combination of superb resolution and a natural,  
relaxed quality will draw you into the music, time  
and time again.  
This level of performance has been implemented  
using the highest level of workmanship and  
materials. You can be assured that the Ayre V-6x  
will provide you a lifetime of musical enjoyment.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connections and  
Installation  
The Ayre V-6x is easy to hook up and use. The  
following guidelines will ensure that the installation  
goes smoothly.  
Location  
Do not stack the Ayre V-6x  
directly with other components,  
as this may restrict the air  
flow or induce hum into the  
audio circuitry.  
A good location for your power amplifier is on the  
floor between your loudspeakers, or in an  
open-backed cabinet, or on a shelf. The Ayre V-6x  
produces a moderate amount of heat during  
operation. Be sure to provide at least three inches  
(75 mm) of air space above the amplifier.  
It is important to maintain an adequate  
supply of air flow to avoid overheating  
the amplifier.  
AC Power  
The best sound quality is normally achieved when  
the V-6x is plugged directly into an unswitched  
wall outlet, without using any power strips or power  
line conditioners.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Inputs  
When you have a choice, a  
balanced connection will  
usually offer slightly higher  
sound quality.  
The power amplifier can be driven by a  
surround-sound processor or preamplifier. There are  
two sets of input connectors for each installed  
channel of the Ayre V-6x. The RCA connectors  
accept signals from unbalanced sources, while the  
XLR connectors are for balanced sources.  
Only one set of inputs  
(balanced or unbalanced) may  
be connected at a time.  
A small toggle switch near the input connectors  
selects either the balanced or unbalanced inputs.  
Note that the input selector switch for one channel  
will be in the “up” position, while the other  
channel’s input selector switch will be in the  
“down” position.  
Using the incorrect position on  
the input selector switches will  
not harm the equipment, and  
the amplifier may even seem to  
operate normally. However,  
some sonic degradation occurs  
in this situation.  
Selecting “Unbal” connects the inverting input to  
ground through an isolation resistor. Therefore, the  
incorrect setting of this switch forces a balanced  
source to operate in unbalanced mode. Conversely, if  
the selector is set to “Bal” while using an  
unbalanced source, the unused inverting input is  
susceptible to hum pick up and radio-frequency  
interference.  
Pass-Through Outputs  
The pass-through output  
connector is wired in parallel  
with the input connector.  
Each channel features a pass-through output,  
supplied via an XLR connector. This allows  
multiple channels to be driven with a single source  
and is especially useful for subwoofers, passive bi- or  
tri-amplification, or distributed sound systems.  
Simply use a balanced cable to connect the  
pass-through output of one channel to the XLR  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
¡Attention! — Balanced Outputs  
Do Not Connect Output Terminals to Ground  
V-6 Power Amplifier S.N.  
Unbal  
Bal  
Unbal  
Unbal  
Bal  
Input Sel  
Input Sel  
Input Sel  
Pass-Through  
Output  
Pass-Through  
Output  
Pass-Through  
Output  
Trigger In/Out  
Bal  
Fuse  
-
+
Fuse  
Fuse  
-
+
Fuse  
Fuse  
-
+
Fuse  
Volts  
50/60 Hertz  
1800 W Max  
Fuse  
+
-
Fuse  
Fuse  
+
-
Fuse  
Fuse  
+
-
Fuse  
Pass-Through  
Output  
Bal  
Pass-Through  
Output  
Bal  
Pass-Through  
Output  
Bal  
Input Sel  
Input Sel  
Input Sel  
Unbal  
Unbal  
Unbal  
Boulder, Colorado USA  
A y r e  
input of another channel on the same amplifier, or of  
another amplifier with true balanced inputs.  
The pass-through output does  
not convert unbalanced sources  
If you wish to drive an unbalanced amplifier from  
the pass-through outputs, you will need to use  
XLR-to-RCA adapters. These should be configured  
so that pin 1 of the XLR is connected to the shell of  
the RCA connector, and pin 2 of the XLR is  
to a true balanced signal.  
connected to the center pin of the RCA connector.  
Loudspeaker Outputs  
The heavy-duty output  
terminals of the Ayre V-6x  
work best with speaker cables  
using spade lugs.  
The Ayre V-6x drives the loudspeakers with  
balanced outputs. Since none of the output  
terminals are grounded, connecting any of them to  
ground may result in damage to the amplifier.  
Do not connect the loudspeaker  
outputs to any speaker switch-box,  
accessory, or test equipment that has a  
common ground connection.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controls and  
Operation  
The Ayre V-6x has a front panel control for normal  
stand-alone operation. The amplifier may also be  
controlled via a “trigger” input in a home-theater.  
Power Switches  
The master power switch on  
the rear panel also  
incorporates a circuit breaker.  
There are two power switches on the Ayre V-6x.  
The master power switch on the rear panel is  
normally intended to be left on at all times. The  
front-panel switch selects between the “Standby”  
and “Operate” modes.  
When the master power switch is first turned on,  
the front panel indicator light will glow red for  
approximately one second. During this time, the  
unit is in “Warm-Up” mode and the front-panel  
switch is inoperable.  
Red = Warm-Up  
Green = Standby  
Blue = Operate  
After the circuitry has stabilized, the indicator light  
will change to green, indicating that the unit is in  
“Standby” mode and is ready for operation. When  
the listener presses the front-panel switch, the unit  
is in “Operate” mode and the indicator light glows  
blue.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
In the green “Standby” mode the output stage is  
turned off, while the input circuitry remains  
powered. This allows the unit to warm up quickly  
for optimal sonic performance, while reducing the  
power consumption from 60 watts per installed  
channel to 10 watts total.  
Trigger Input  
Use a 1/8" mini-phone plug  
with a positive voltage of  
between +5 and +12 VDC  
at the tip to operate the trigger  
input.  
A trigger input is provided on the rear panel of the  
V-6x to allow for remote switching between the  
green “Standby” and blue “Operate” modes. The  
two trigger input jacks are wired in parallel. Either  
jack can act as an input or a pass-through output to  
allow for “daisy-chaining” of multiple devices.  
The unit is shipped from the factory in the  
level-sensitive mode, which is compatible with most  
equipment. During level-sensitive operation,  
applying a voltage to the trigger input will force the  
amplifier to the “Operate” mode. In this state, the  
front panel switch is inoperative. When the applied  
voltage drops to zero, the unit reverts to “Standby”  
and the front panel switch may be used to manually  
control the unit.  
Some equipment instead utilizes pulses as a trigger  
signal. The V-6x can also accommodate these units.  
To change trigger modes, turn the rear panel switch  
“Off” for about 30 seconds to discharge the internal  
voltages. Then press and hold the front panel switch  
while turning the rear panel switch “On”. The status  
LED will rapidly flash red (about 10 Hz) to indicate  
that the pulse-sensitive mode has been selected.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repeating this procedure will revert the unit back  
to the level-sensitive mode, as indicated by the  
status LED slowly flashing red (about 1 Hz).  
In the pulse-sensitive mode, a positive-going pulse  
edge will toggle the amplifier between the  
“Standby” and “Operate” states, duplicating the  
action of the front-panel switch. In this mode the  
front panel switch is always operative. However,  
operating the unit with the front panel switch may  
put the unit out of “synch” with the control device.  
If this should occur, simply press the front panel  
switch to restore “synch”.  
Channel Configuration  
Each channel of the V-6x is a self-contained module  
(except for the power supply). If you wish to add  
channels to your amplifier after purchase, additional  
modules may easily be installed by your authorized  
Ayre dealer.  
The V-6x will hold a maximum of six channels.  
There are three independent power supplies  
installed. One power supply feeds the two left-hand  
slots, another feeds the two center slots, and another  
feeds the two right-hand slots.  
Break-In  
100 to 500 hours of music  
played through the system will  
ensure full break-in.  
Due to the manufacturing processes used for the  
wires and capacitors, a break-in period is necessary  
for the amplifier to reach its full sonic potential.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Numbers and  
Specifications  
Power Output  
150 watts per channel continuous into 8 ohms  
300 watts per channel continuous into 4 ohms  
Input Impedance  
100 k– unbalanced inputs  
200 k– balanced inputs (100 kper phase)  
XLR Input Polarity  
Pin 1 = Ground  
Pin 2 = Non-inverting (Positive)  
Pin 3 = Inverting (Negative)  
Gain  
Frequency Response  
Power Consumption  
26 dB  
DC - 200 kHz  
10 watts in standby mode  
60 watts per installed channel in operating mode,  
(no signal)  
Dimensions  
Weight  
18" W x 19" D x 7-¾" H  
46 cm x 48 cm x 20 cm  
80 pounds (36 kg)  
plus 6.5 pounds (3 kg) per installed channel  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
In Case of  
Trouble  
The Ayre V-6x provides comprehensive protection  
for both the amplifier and your loudspeakers,  
including faults that may occur in your source  
components.  
Overheating  
Sensors located on each audio  
module will shut the amplifer  
off if the heatsink temperature  
reaches 175° F (80° C).  
If the unit is operated at high playback levels with  
insufficient ventilation, the internal temperature  
may become too high, triggering the thermal  
protection circuitry. In this case, the amplifier will  
shut down, the front panel status LED will display  
both the red and green elements simultaneously,  
and the front panel switch will be inoperative.  
If overheating occurs, be sure  
to correct the cause before  
continuing to use the  
amplifier.  
Once the unit has cooled, the red LED element will  
go out, leaving the unit in the green “Standby”  
condition. To restore the unit to the blue “Operate”  
mode, simply press the front panel button.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rail Fuses  
Indicator LEDs on the rear of  
the unit will glow red when  
one of the fuses blows. Please  
refer fuse replacement to a  
qualified service technician.  
Internal fuses on the power supply rails of each  
channel protect the loudspeakers from excessive  
current, as well as the amplifier from short-circuits.  
If one of these rail fuses blows, that channel will fail  
to operate, although the front panel LED will  
typically continue to glow blue.  
Do not remove the amplifier cover.  
Hazardous voltages may exist inside the  
unit.  
Use of rail fuses other than a 5 x 20 mm  
fast-acting 10 ampere unit may damage  
the unit and void the warranty.  
AC Line Voltage  
If the AC line voltage drops below 80% of normal  
(brown-out), the unit will revert to the red  
“Warm-Up” mode with the outputs muted. After  
the voltage returns to normal, the initial warm-up  
cycle will begin again and the unit will then revert  
to the green “Standby” mode. Press the front panel  
button to return the unit to the blue “Operate”  
mode.  
DC Offset  
The Ayre V-6x incorporates a circuit to detect the  
presence of DC at the output terminals. In this  
situation, the amplifier reverts to the red  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
“Warm-Up” mode, and power is immediately  
removed from the output stage.  
After correcting the suspected fault condition, a  
press of the front panel button is required to return  
the unit to the green “Standby” condition. A second  
press of the button will restore the unit to the blue  
“Operate” mode. If the fault is still present when the  
front panel switch is pressed the second time, the  
unit will immediately revert to the red “Warm-Up”  
mode.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Statement of  
Warranty  
Please take a moment to fill  
out and return the enclosed  
warranty registration card.  
Your Ayre V-6x power amplifier is warranted  
against defects in workmanship and materials for a  
period of five years from the date of purchase. This  
warranty is transferable to subsequent purchasers  
within the original five-year period. All warranty  
claims must be made through an authorized Ayre  
dealer or distributor.  
Warranty Statement  
1. Ayre Acoustics, Inc. (Ayre) warrants the materials  
and workmanship of this product for a period of five  
years from date of first purchase. If any defects are  
found in the materials or workmanship of this Ayre  
product within the warranty period, the unit will be  
repaired or replaced by Ayre or its authorized agent.  
2. Purchaser must return the product, packed in the  
original shipping carton, freight prepaid to:  
Ayre Acoustics, Inc.  
2300-B Central Avenue  
Boulder, Colorado 80301  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
or to Ayre’s authorized agent.  
3. Ayre reserves the right to inspect any product  
that is the subject of any warranty claim prior to  
repairing or replacing it. Final determination of  
warranty coverage lies solely with Ayre.  
Out-of-warranty claims will be billed for labor,  
materials, return freight, and insurance as required.  
Any product for which a warranty claim is accepted  
will be returned to the purchaser and the cost of  
shipping and insurance will be factory prepaid  
within the boundaries of the USA. Units to be  
shipped outside of the USA will be shipped freight  
collect only.  
4. Ayre strives to manufacture the finest possible  
equipment, and therefore reserves the right to make  
improvements on its products, without necessarily  
assuming an obligation to retrofit such changes  
upon its previously manufactured models.  
5. The above warranty is the sole warranty given by  
Ayre, and is in lieu of all other warranties. All  
implied warranties, including warranties of  
merchantability or fitness for any particular purpose  
shall be strictly limited in duration to five years  
from the date of original purchase, and upon  
expiration of the warranty period (five years), Ayre  
shall have no further obligation of any kind, whether  
express or implied. Further, Ayre shall in no event  
be obligated for any incidental or consequential  
damages as a result of any defect or any warranty  
claim, whether express or implied.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Ayre does not authorize any third party,  
including any dealer or sales representative to  
assume any liability of Ayre or make any warranty  
for Ayre. The unit must not have been altered or  
improperly serviced. The serial number on the unit  
must not have been altered or removed.  
7. Warranty registration cards must be completed  
and mailed to Ayre within 30 days of purchase. Ayre  
may, at its option, require from the purchaser valid  
proof of purchase (dated copy or photocopy of  
dealer’s original invoice).  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Place for  
Notes  
16  
Rev. 1.1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ayre Acoustics, Inc.  
2300-B Central Avenue  
Boulder, Colorado 80301  
+1-303-442-7300  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acnodes Personal Computer PCH 5120 User Manual
Alliance Laundry Systems Washer BF35PV User Manual
Allied Telesis Switch X3112 User Manual
Alvarion Network Router SW VERSION 51 User Manual
AMD Computer Hardware NX800LX User Manual
American DJ Indoor Furnishings MIC160 User Manual
Atlona Home Theater Server AT AV0808N User Manual
AVERATEC GPS Receiver 320 GPS User Manual
AVerMedia Technologies DVR NV 6000 EXP User Manual
Axor Plumbing Product 06064XX0 User Manual