AXIS T8120 Midspan 15 W 1-port  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AXIS T8120 Installation Guide  
Page 3  
AXIS T8120 Installation Guide  
Safety Information  
• When transporting the Axis product, use the original packaging or  
equivalent to prevent damage to the product.  
• Store the Axis product in a dry and ventilated environment.  
• Avoid exposing the Axis product to vibration, shocks or heavy pres-  
sure and do not install the product on unstable brackets, since this  
could cause damage to the product.  
• Do not attempt to repair the product by yourself, contact Axis or  
your Axis reseller for service matters.  
• The product should connected to PoE networks only, without rout-  
ing to the outside plant.  
• Only qualified personnel can install or remove the product.  
• The power cord must have regulatory agency approval for the spe-  
cific country in which is used, (for example UL, CSA, VDE on).  
• The power cord must be a three-conductor type (two current car-  
rying conductors, one ground conductor) terminated on one end by  
an IEC 60320 appliance coupler (for connecting to the product) and  
on the other end by a plug containing a ground (earthing) contact.  
The power cord must be rated for a minimum of 250 V AC RMS op-  
eration, with a minimum rated current  
capacity of 5 amps (or a minimum wire gauge of 18 AWG (0.75  
mm2).  
• A product installed in Australia requires power cords with a  
minimum wire gauge of 16 AWG (1.0 mm2).  
• The products “DATA IN” and “DATA & POWER OUT” ports are shield-  
ed RJ45 data sockets. They cannot be used as Plain Old Telephone  
Service (POTS) telephone sockets. Only RJ45 data connectors can  
be connected to these sockets.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 4  
AXIS T8120 Installation Guide  
• The AC wall socket outlet must be near the product and easily ac-  
cessed. AC power can be removed from the product by disconnect-  
ing the AC power cord from either the wall socket-outlet or from  
the products appliance coupler.  
• The products “DATA IN” and “DATA & POWER OUT” interfaces are  
qualified as Safety Extra-low Voltage (SELV) circuits according to  
IEC 60950-1. These interfaces can only be connected to SELV  
interfaces on other equipment.  
• The product should only be connected to the IP device with which  
it was bought. Using the product with other IP devices can cause  
damage to the IP device.  
• Follow basic electricity safety measures whenever connecting the  
device to its power source.  
• Read the installation instructions before connecting the product to  
its power source.  
• A voltage mismatch can cause equipment damage and may pose a  
fire hazard. If the voltage indicated on the label is different from  
the power outlet voltage, do not connect the product to this power  
outlet.  
• The product can be used only in Restricted Access Locations.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AXIS T8120 Installation Guide  
Functions and Features  
Page 5  
The Power over Ethernet (PoE) Midspan adds 48V DC to unused (non-  
data) wires (Mode B) in a standard Category 5 Ethernet cable. As a  
result, the PoE Midspan delivers both data and power to the terminal.  
The device is designed to meet the IEEE802.3af standard.  
Preliminary steps  
• Ensure AC power is applied to the PoE Midspan using an  
operational AC cable with an appropriate ground connection.  
• Ensure that output Ethernet cable is connected to the  
Data & Power Out port.  
• Verify that a power ready Ethernet compatible device is connected.  
Note: Do not use a cross over cable between the PoE Midspan output port  
and the load device.  
Mounting  
Note the following before mounting the PoE Midspan to a fixed location:  
• The PoE Midspan may be wall or bench mounted using the rear  
side holes.  
• Do not cover the PoE Midspan or block the airflow to the PoE with  
any foreign objects. Keep the PoE Midspan away from  
excessive heat and humidity, and keep it free from vibration  
and dust.  
• Ensure that the cable length from the Ethernet network source to  
the terminal does not exceed 100 meters (333 ft). The PoE is not a  
repeater and does not amplify the Ethernet data signal.  
• Use a splitter if desired, ensure that the splitter is connected close  
to the terminal and not on the Midspan.  
• There is no "on-off" switch, simply plug the PoE Midspan to an  
AC power source.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 6  
AXIS T8120 Installation Guide  
Installing the Unit  
1. Connect the PoE Midspan to an AC outlet (100-240 V AC), using a  
standard power cable.  
2. Connect the unit Data In jack (input) to the remote Ethernet  
network switch Patch panel.  
3. Connect the Data & Power Out jack (output) to the terminal.  
Hardware Overview  
Port connectivity  
indicator  
Data and Power out  
Data in  
CAT 5 Cab le  
Output port  
Terminal  
Input port  
Ethernet  
Indicators  
LED  
Indicated Behavior  
Power is on (power is active)  
A remote terminal is connected  
Overload state or short-circuit  
Yellow On  
Green On  
Green Blinking  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AXIS T8120 Installation Guide  
Page 7  
Specifications  
Environmental Specifications  
Mode  
Temperature  
Humidity  
0 °C to 40 °C (32 °F to 104 °F)  
-20 °C to 70 °C (-4 °F to 158 °F)  
Operating  
Storage  
10 to 90% RH (no condensation  
allowed)  
Electrical Specifications  
100 to 240V AC (50/60 Hz)  
0.5 A (maximal)  
Input voltage  
Input current  
Available Output Power (Maximum)  
Nominal Output Voltage  
16.8 W  
48V DC  
Ethernet Interface  
Input (Data In): Ethernet 10/100Base-T  
Output (Data & Power Out):  
RJ45 female socket  
RJ45 female socket, with DC  
voltage on wire pairs 4-5 and 7-8.  
Ethernet 10/100Base-T, plus 48 VDC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 8  
AXIS T8120 Installation Guide  
Troubleshooting  
Symptom  
Corrective Steps  
Midspan does not power up 1. Verify that an approved power cord is used.  
2. Verify that the voltage at the power inlet is  
between 100 and 240V AC.  
3. Remove and re-apply power to the device and  
check the indicators during power up sequence.  
A port indicator is not lit 1. The Midspan did not detect a device and  
and the Midspan does not  
operate  
therefore the port is not enabled.  
2. Verify that the device is designed for PoE  
operation  
3. Verify that you are using a standard Category 5/  
5e/6, straight-wired cable, with four pairs  
4. If there is a connected external power splitter,  
replace it to verify that it is functioning properly  
5. Ensure that the input Ethernet cable is connected  
to the Data In port  
6. Verify that the device is connected to the Data &  
Power port.  
7. Try to reconnect the same device into a different  
Midspan. If it works, there is probably a faulty  
port or RJ45 connection.  
8. Verify that there is no short over any of the  
twisted pair cables or over the RJ45 connectors.  
The end device operates, but 1. Verify that the port indicator on the front panel is  
there is no data link  
continuously lit.  
2. If an external power splitter is in use, replace it  
with a known-good splitter.  
3. Verify that for this link, you are using standard  
UTP/FTP Category 5 straight (non-crossover)  
cabling, with all four pairs.  
4. Verify that the Ethernet cable length is less than  
100 meters from the Ethernet source to the load/  
remote terminal.  
5. Try to reconnect the same device into a different  
Midspan. If it works, there is probably a faulty  
port or RJ45 connection.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Liability  
Every care has been taken in the preparation of this document. Please inform your local Axis  
office of any inaccuracies or omissions. Axis Communications AB cannot be held responsible for  
any technical or typographical errors and reserves the right to make changes to the product and  
documentation without prior notice. Axis Communications AB makes no warranty of any kind  
with regard to the material contained within this document, including, but not limited to, the  
implied warranties of merchantability and fitness for a particular purpose. Axis Communications  
AB shall not be liable nor responsible for incidental Support or consequential damages in  
connection with the furnishing, performance or use of this material. This product is only to be  
used for its intended purpose.  
Notice  
Axis’ policy is to improve its products as new technology, components, software, and firmware  
become available. Axis, therefore, reserves the right to change specifications without prior  
notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Guide  
Ver.2.1  
Printed: October 2014  
Part No. 60330  
AXIS T8120 15W Midspan 1-port  
© Axis Communications AB, 2012-2014  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acoustic Research Speaker System AW822 User Manual
Acu Rite Clock Radio 120610 User Manual
Addonics Technologies Computer Drive HDU11SITDR User Manual
Aiphone Intercom System ts 6k User Manual
Aiwa Stereo System FR TC5000 User Manual
Allied Telesis Switch Patch 86261 04 User Manual
Alpine Car Stereo System CDE W233R User Manual
AMD Computer Hardware x1700 FSC User Manual
Audiovox Speaker IPD SBBT User Manual
Eureka Tents Tent Nergy 9 User Manual