AutoView® 2000
Installer/User Guide
Guide d’installation et d’utilisation
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoView 2000
Installer/User Guide
Avocent, the Avocent logo, The Power of Being There, AutoView and
OSCAR are registered trademarks of Avocent Corporation or its
affiliates. All other marks are the property of their respective owners.
2004 Avocent Corporation. All rights reserved.
590-284-116C
Download from Www.Somanuals.com. All Manuals Search And Download.
USA Notification
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
Canadian Notification
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set
out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présente appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le
Ministère des Communications du Canada.
Japanese Approvals
Safety and EMC Approvals and Markings
UL, FCC, cUL, ICES, CE, N, GS, IRAM, GOST, VCCI, MIC, C-Tick
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
Table of Contents
List of Figures .................................................................................................................. v
List of Tables.................................................................................................................. vii
Chapter 1: Product Overview.......................................................................................... 1
Features and Benefits ........................................................................................................................1
AVRIQ Intelligent Module .................................................................................................................1
Safety Precautions .............................................................................................................................3
Chapter 2: Installation ..................................................................................................... 5
Getting Started...................................................................................................................................5
Supplied with the AutoView 2000 switch....................................................................................5
Rack Mounting Your AutoView 2000 Switch.....................................................................................5
Installing the AutoView 2000 Switch.................................................................................................6
Cascading AutoView 2000 Switches..................................................................................................8
Adding Legacy Switches ..................................................................................................................10
Setting Up Your AutoView 2000 Switching System .........................................................................11
Chapter 3: Basic Operations......................................................................................... 13
Controlling Your System at the Analog Ports..................................................................................13
Viewing and Selecting Ports and Servers........................................................................................13
Navigating the OSCAR Interface.....................................................................................................15
Configuring OSCAR Interface Menus .............................................................................................17
Assigning server names ............................................................................................................18
Assigning device types..............................................................................................................19
Changing the display behavior.................................................................................................21
Controlling the status flag ........................................................................................................22
Setting console security ............................................................................................................23
Displaying Version Information ......................................................................................................26
Scanning Your System......................................................................................................................27
Running System Diagnostics............................................................................................................29
Broadcasting to Servers...................................................................................................................31
Changing Your Switch Mode ...........................................................................................................33
Download from Www.Somanuals.com. All Manuals Search And Download.
iv
AutoView 2000 Installer/User Guide
Appendices..................................................................................................................... 35
Appendix A: FLASH Upgrades........................................................................................................ 35
Appendix B: Technical Specifications .............................................................................................40
Appendix C: Technical Support.......................................................................................................42
Index................................................................................................................................ 43
Download from Www.Somanuals.com. All Manuals Search And Download.
v
LIST OF FIGURES
List of Figures
Figure 1.1: AutoView 2000 Switch...................................................................................................1
Figure 1.2: Example of an AutoView 2000 Switch Configuration ....................................................3
Figure 2.1: AutoView 2000 Switch Horizontal Installation .............................................................6
Figure 2.2: Basic AutoView 2000 Switch Configuration .................................................................7
Figure 2.3: AutoView 2000 Switch Configuration with a Cascaded Switch ....................................9
Figure 2.4: AutoView 2000 Switch Configuration with a Legacy KVM Switch.............................10
Figure 3.1: Example of Configured Main Dialog Box ...................................................................13
Figure 3.2: Setup Dialog Box.........................................................................................................17
Figure 3.3: Names Dialog Box.......................................................................................................18
Figure 3.4: Name Modify Dialog Box ............................................................................................19
Figure 3.5: Devices Dialog Box .....................................................................................................20
Figure 3.6: Device Modify Dialog Box ..........................................................................................20
Figure 3.7: Menu Dialog Box.........................................................................................................21
Figure 3.8: Flag Dialog Box ..........................................................................................................22
Figure 3.9: Set Position Flag .........................................................................................................23
Figure 3.10: Security Dialog Box...................................................................................................24
Figure 3.11: Version Dialog Box ...................................................................................................26
Figure 3.12: AVRIQ Selection Dialog Box.....................................................................................27
Figure 3.13: AVRIQ Version Dialog Box.......................................................................................27
Figure 3.14: Scan Dialog Box ........................................................................................................28
Figure 3.15: Commands Dialog Box..............................................................................................29
Figure 3.16: Diagnostics Dialog Box.............................................................................................30
Figure 3.17: Diagnostics Warning Dialog Box..............................................................................31
Figure 3.18: Broadcast Dialog Box ...............................................................................................32
Figure 3.19: Broadcast Enable Confirm/Deny Dialog Box ...........................................................33
Figure 3.20: Switch Dialog Box .....................................................................................................34
Figure A.1: AVRIQ Status Dialog Box ...........................................................................................36
Figure A.2: AVRIQ Upgrade Dialog Box.......................................................................................37
Figure A.3: Version Dialog Box.....................................................................................................37
Figure A.4: AVRIQ Selection Dialog Box ......................................................................................38
Figure A.5: AVRIQ Version Dialog Box ........................................................................................38
Figure A.6: AVRIQ Load Dialog Box.............................................................................................39
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
AutoView 2000 Installer/User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
vii
LIST OF TABLES
List of Tables
Table 2.1: Legacy Switch Support ...................................................................................................10
Table 3.1: OSCAR Interface Status Symbols...................................................................................14
Table 3.2: OSCAR Interface Navigation Basics.............................................................................15
Table 3.3: Setup Features to Manage Routine Tasks for Your Servers..........................................17
Table 3.4: OSCAR Interface Status Flags ......................................................................................22
Table 3.5: Diagnostic Test Details .................................................................................................30
Table B.1: Product Specifications ..................................................................................................40
Download from Www.Somanuals.com. All Manuals Search And Download.
viii
AutoView 2000 Installer/User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
1
CHAPTER
Product Overview
1
Features and Benefits
The multiuser, 16-port AutoView® 2000 switch integrates Avocent field-proven analog keyboard,
video and mouse (KVM) switching technology with advanced cable management, flexible access
for two simultaneous users and a patented, next-generation user interface. The AutoView 2000
KVM switch conveniently supports all major server platforms and features powerful on-screen
management for easy system configuration and server selection.
A unique benefit of the AutoView 2000 switch is the AVRIQ intelligent module. The AVRIQ
module with CAT 5 design dramatically reduces cable clutter, while providing optimal resolution
and video settings. The built-in memory of the AVRIQ module simplifies configuration by
assigning and retaining unique server names and Electronic ID (EID) numbers for each attached
server. The AVRIQ module is powered directly from the server and provides Keep Alive
functionality even if the AutoView switch is not powered.
Figure 1.1: AutoView 2000 Switch
AVRIQ Intelligent Module
AVRIQ modules allow direct KVM connectivity to servers in your AutoView switch. Each
AutoView 2000 switch has 16 Avocent Rack Interface (ARI) ports for connecting
AVRIQ modules.
Utilizing an AVRIQ module, you can attach additional switches to expand your AutoView switch
system. This flexibility allows you to add capacity as your data center grows.
Download from Www.Somanuals.com. All Manuals Search And Download.
2
AutoView 2000 Installer/User Guide
Multiplatform support
The AVRIQ modules available with the AutoView 2000 switch support PS/2, Sun™ and USB
server environments. Using the OSCAR® graphical user interface in conjunction with these
modules allows you to switch easily across platforms.
OSCAR graphical user interface
An AutoView 2000 switch uses the OSCAR interface, which features intuitive menus to configure
your switch system and select computers. Computers can be identified by unique name, EID or port
number, allowing you to assign unique server names.
Security
The OSCAR interface allows you to protect your system with a screen saver password. After a
user-defined time, the screen saver mode engages and access is prohibited until the appropriate
password is entered to reactivate the system.
Operation modes
The OSCAR user interface provides convenient operation modes for easy system administration of
the AutoView 2000 switch. These modes (Broadcast, Scan, Switch and Share) allow you to manage
your switching activities. Chapter 3 explains these modes in detail.
Video
The AutoView 2000 switch provides optimal resolution for analog VGA, SVGA and XGA video.
Achieve resolutions of up to 1600 x 1200 with a 10 foot cable and up to 800 x 600 with a 50 foot
cable. Resolutions will vary depending upon the length of cable separating your switch and servers.
Plug and Play
The AutoView 2000 switch also supports Display Data Channel (DDC) Plug and Play, which
automates configuration of the monitor and is compliant with the VESA DDC2B standard.
FLASH upgradable
Upgrade your firmware at any time through a simple update utility to ensure that your AutoView
switching system is always running the most current version available. Both the AutoView 2000
switch and the AVRIQ modules are FLASH upgradable. See Appendix A for more information.
Cascading expansion
Each AutoView 2000 switch supports up to16 directly attached servers and can conveniently scale
to support more. You can expand your system using cascadable Avocent products such as other
AutoView or OutLook® switches. This extra “cascade” of units allows you to attach up to 256
servers in one system. See Chapter 2 for more information.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1: Product Overview
3
AutoView 2000 Switch
(cascaded)
Legacy Switch
(cascaded)
Rack of Servers
AVRIQ
Module
Critical Server
Analog
Connection
AutoView 2000 Switch
(main)
Analog
Connection
Figure 1.2: Example of an AutoView 2000 Switch Configuration
Safety Precautions
To avoid potential video and/or keyboard problems when using Avocent products:
•
Ιf the building has 3-phase AC power, ensure that the computer and monitor are on the same
phase. For best results, they should be on the same circuit.
•
Use only Avocent-supplied cable to connect computers and KVM switches. Avocent
warranties do not apply to damage resulting from user-supplied cable.
To avoid potentially fatal shock hazard and possible damage to equipment, please observe the
following precautions:
•
•
Do not use a 2-wire extension cord in any Avocent product configuration.
Test AC outlets at the computer and monitor for proper polarity
and grounding.
•
Use only with grounded outlets at both the computer and monitor. When using a backup
Uninterruptible Power Supply (UPS), power the computer, the monitor and the AutoView
2000 switch off the supply.
NOTE: The AC inlet is the main disconnect.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
AutoView 2000 Installer/User Guide
Rack mount safety considerations
•
Elevated Ambient Temperature: If installed in a closed rack assembly, the operation
temperature of the rack environment may be greater than room ambient. Use care not to exceed
the rated maximum ambient temperature of the unit.
•
•
•
Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of
airflow required for safe operation of the equipment is not compromised.
Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
Circuit Overloading: Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of circuits might have on overcurrent protection
and supply wiring. Consider equipment nameplate ratings for maximum current.
•
Reliable Earthing: Reliable earthing of rack mounted equipment should be maintained. Pay
particular attention to supply connections other than direct connections to the branch circuit
(for example, use of power strips).
Download from Www.Somanuals.com. All Manuals Search And Download.
5
CHAPTER
Installation
2
Getting Started
Before installing your AutoView 2000 switch, refer to the following list to ensure you have all
items that shipped with the appliance as well as other items necessary for proper installation.
Supplied with the AutoView 2000 switch
•
•
•
•
•
•
AutoView 2000 switch
Power cord
One null modem serial cable
Rack mounting kit
AutoView 2000 Installer/User Guide
AutoView 2000 Quick Installation Guide
Additional items needed
One AVRIQ module and UTP cabling per attached server or switch
Rack Mounting Your AutoView 2000 Switch
Your AutoView 2000 switch may be rack mounted using brackets supplied in your rack mounting kit.
Before installing the appliance and other components in the rack cabinet (if not already installed),
stabilize the rack in a permanent location. Install your equipment starting at the bottom of the rack
cabinet, then work to the top. Avoid uneven loading or overloading of rack cabinets.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
AutoView 2000 Installer/User Guide
Figure 2.1: AutoView 2000 Switch Horizontal Installation
CAUTION: Rack Loading - Overloading or uneven loading of racks may result in shelf or rack failure, causing
damage to equipment and possible personal injury. Stabilize racks in a permanent location before loading
begins. Mount components beginning at the bottom of the rack, then work to the top. Do not exceed your rack
load rating.
To install the 1U switch mounting bracket:
1. Remove the first two screws on each side.
2. Line up the holes in the “long side” of the kit’s side brackets with the screw holes in the switch.
3. With a Phillips screwdriver, fasten the mounting brackets to the switch using two screws on
each side.
4. Attach four cage nuts or clip nuts to the rack mounting flange of the rack cabinet so that the nut
is positioned on the inside of the rack.
NOTE: Nuts are not included with the rack mount kit.
5. Mount the switch assembly to the rack cabinet by matching the holes in the “short side” of
each bracket to an appropriate set of matching holes on your rack cabinet. Next, insert the
combination hex head screws through the slots in the bracket and the holes in the mounting
rail, then into the cage nuts or clip nuts.
Installing the AutoView 2000 Switch
Plug the supplied power cord into the back of the appliance and then into an appropriate power
source. Figure 2.2 illustrates one possible configuration for your AutoView 2000 switch. See the
following detailed set of procedures to successfully install your appliance.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
7
CAUTION: To reduce the risk of electric shock or damage to your equipment -
- Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
- Plug the power cord into a grounded (earthed) outlet that is easily accessible at all times.
- Disconnect the power from the unit by unplugging the power cord from either the electrical outlet or the unit.
Analog User B
Configuration Port
(for updating firmware)
AutoView 2000 Switch
Servers 2-16
Analog User A
AVRIQ Module
Server 1
Figure 2.2: Basic AutoView 2000 Switch Configuration
To connect an AVRIQ module to each server:
1. Locate the AVRIQ modules for your AutoView 2000 switch.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
AutoView 2000 Installer/User Guide
2. Attach the appropriately color-coded cable ends to the keyboard, monitor and mouse ports on the
first server you will be connecting to the appliance.
3. Attach one end of the CAT 5 cabling that will run between your AVRIQ module and
AutoView switch to the RJ-45 connector on the AVRIQ module.
4. Connect the other end of the CAT 5 cable to the desired ARI port on the back of your
AutoView switch.
5. Repeat steps 2 to 4 for all servers you wish to attach.
NOTE: When connecting a Sun AVRIQ module, you must use a multi-sync monitor to accommodate Sun
computers that support both VGA and sync-on-green or composite sync.
To connect local peripherals:
1. Select the keyboard, monitor and mouse to be connected to local analog user A.
2. Locate the port set labeled A on the back of the appliance. Connect these peripherals to their
respective ports.
3. Repeat these steps for the local analog port set labeled B on the back of the appliance.
4. Bundle and label the cables for easy identification.
Cascading AutoView 2000 Switches
You can cascade multiple AutoView 2000 switches to enable one or two users to connect to up to
256 servers. In a cascaded system, each ARI (Avocent Rack Interface) port on the main AutoView
2000 switch will connect to the ACI (Avocent Console Interface) port on each cascaded AutoView
2000 switch. Each cascaded switch can then be connected to a server with an AVRIQ module. The
example in Figure 2.3 shows one AutoView 2000 switch cascaded under the main switch, enabling
the connection of up to 15 primary servers and 16 secondary servers. Using this configuration, you
could cascade 16 AutoView 2000 switches under the main switch, enabling the connection of up to
256 servers. Only one level of tiering is supported in this type of configuration, which means that
you cannot cascade additional legacy switches or another AutoView 2000 switch. In this
configuration, the local port OSCAR interface is disabled when the main AutoView 2000 switch is
cascaded below another appliance.
NOTE: As shown in Figure 2.3, only analog user A’s ACI port may be used for the cascaded connection.
To cascade multiple AutoView 2000 switches:
1. Connect the cascaded AutoView 2000 switch to each server as described in the previous
Installing the AutoView 2000 Switch section.
2. Connect the local peripherals to analog user A of the main switch as described in To connect
local peripherals.
3. Attach one end of the CAT 5 cabling that will run between your main and cascaded AutoView
switch to the RJ-45 (ACI) port of analog user A on the cascaded AutoView switch.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
9
4. Attach the other end of the CAT 5 cable to one of the 16 RJ-45 (ARI) ports on the main
AutoView 2000 switch.
NOTE: The system will automatically “merge” the two switches together as one. All servers connected to the
cascaded AutoView 2000 switch will display on the main AutoView 2000 server list in the OSCAR interface.
5. Repeat steps 3 and 4 for all additional (secondary) cascaded AutoView 2000 switches you
wish to attach.
Analog User B
Analog User A
AutoView 2000 Switch
ARI Ports
Primary
Servers
AutoView 2000 Switch (cascaded)
ACI Port
Secondary
Servers
Figure 2.3: AutoView 2000 Switch Configuration with a Cascaded Switch
Download from Www.Somanuals.com. All Manuals Search And Download.
10
AutoView 2000 Installer/User Guide
Adding Legacy Switches
You can add legacy switches to the AutoView 2000 system for easy integration into your existing
configuration. In a cascaded system, each ARI port will accommodate up to 24 servers. See the
following table for legacy switches compatible with the AutoView 2000 switch system.
Table 2.1: Legacy Switch Support
Legacy Product
OutLook ES switch
AutoView switch
Model Numbers
140ES, 180ES, 280ES, 1160ES, 2160ES, 4160ES
AV200-4, AV200-8, AV400-4, AV400-8, AV416, AV424
Local Analog User A
AutoView 2000 Switch
AVRIQ Module
PS/2, USB, Sun and serial
cables are available
AVRIQ Module
OutLook ES Switch
AutoView 200/400 Switch
Server 1
Server 2
Figure 2.4: AutoView 2000 Switch Configuration with a Legacy KVM Switch
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2: Installation
11
To add a legacy KVM switch:
1. Mount the KVM switch into your rack cabinet. Locate a length of CAT 5 cabling to connect
your AutoView 2000 switch and the AVRIQ module for your switch.
2. Attach the keyboard, monitor and mouse connectors of the AVRIQ module to a user port on
your cascaded switch.
3. Attach one end of the CAT 5 cabling to the RJ-45 connector on the AVRIQ module.
4. Connect the other end of the CAT 5 cable to an available port on the back of your
AutoView 2000 switch.
5. Connect the servers to your cascaded switch according to the instructions included with
the device.
6. Power cycle the cascaded switch to enable its local user port to recognize the AVRIQ module.
7. Repeat steps 2 to 5 for all cascaded switches you wish to attach to your system.
To connect local peripherals:
1. Select the keyboard, monitor and mouse to be connected to local user A.
2. Locate the port set labeled A on the back of the appliance. Connect these peripherals to their
respective ports.
3. For the multiuser, 16-port AutoView 2000 switch, repeat steps 1 and 2 for the local analog port
set labeled B.
4. Bundle and label the cables for easy identification.
Setting Up Your AutoView 2000 Switching System
With the AutoView 2000 switching system, you can auto detect and configure each port on your
appliance. Chapter 3 provides detailed instructions on naming customizing and OSCAR interface
setup and configuration.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
AutoView 2000 Installer/User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
13
CHAPTER
Basic Operations
3
Controlling Your System at the Analog Ports
The AutoView 2000 switch features two analog port sets on the back of the unit that allow you to
connect a monitor and a PS/2 keyboard and mouse for direct analog access. The AutoView 2000
switch uses the OSCAR interface, which uses intuitive menus to configure your system and
select computers.
Viewing and Selecting Ports and Servers
Use the OSCAR Main dialog box to view, configure and control servers in the AutoView 2000
switch system. View your servers by name, port or by the unique Electronic ID number (EID)
embedded in each AVRIQ module. You will see an OSCAR interface-generated port list by default
when you first launch the OSCAR interface.
The Port column indicates the ARI port to which a server is connected. If you connect a legacy
KVM switch to the main AutoView 2000 switch or an AutoView 2000 cascaded switch, the port
numbering displays the ARI port first, then the switch port to which the server is connected. For
example, in Figure 3.1, servers 04-03 and 01-02 are connected to switches.
To access the Main dialog box:
Press Print Screen to launch the OSCAR interface. The Main dialog box displays.
Figure 3.1: Example of Configured Main Dialog Box
Download from Www.Somanuals.com. All Manuals Search And Download.
14
AutoView 2000 Installer/User Guide
NOTE: You can also press the Control key twice within one second to launch the OSCAR interface. You can
use this key sequence in any place you see Print Screen throughout this installer/user guide.
Viewing the status of your switch
The status of the servers in your system is indicated in the right columns of the Main dialog box.
The following table describes the status symbols.
Table 3.1: OSCAR Interface Status Symbols
Symbol
Description
AVRIQ module is online (green circle).
AVRIQ module is offline or is not operating properly.
Server is cascaded through a cascade legacy switch. The switch is online and has power.
Server is cascaded through a cascade legacy switch. The switch is offline or has no power.
AVRIQ module is being upgraded (yellow circle).
AVRIQ module is being accessed by the indicated user channel (green channel letter).
AVRIQ module is blocked by the indicated user channel (black channel letter).
Selecting servers
Use the Main dialog box to select servers. When you select a server, the appliance reconfigures the
keyboard and mouse to the proper settings for that server.
To select servers:
Double-click the server name, EID or port number.
-or-
If the display order of your server list is by port (Port button is depressed), type the port number
and press Enter.
-or-
If the display order of your server list is by name or EID number (Name or EID button is
depressed), type the first few characters of the name of the server or the EID number to establish it
as unique and press Enter.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
15
To select the previous server:
Press Print Screen and then Backspace. This key combination toggles you between the previous
and current connections.
To disconnect the user from a server:
Press Print Screen and then Alt+0. This leaves the user in a free state, with no server selected. The
status flag on your desktop displays Free.
Soft switching
Soft switching is the ability to switch servers using a hotkey sequence. You can soft switch to a server by
pressing Print Screen and then typing the first few characters of its name or number. If you have set a
Screen Delay Time and you press the key sequences before that time has elapsed, the OSCAR interface
will not display.
To configure servers for soft switching:
1. Press Print Screen to launch the OSCAR interface. The Main dialog box displays.
2. Click Setup - Menu. The Menu dialog box displays.
3. For Screen Delay Time, type the number of seconds of delay desired before the Main dialog
box is displayed after Print Screen is pressed.
4. Click OK.
To soft switch to a server:
1. To select a server, press Print Screen. If the display order of your server list is by port (Port
button is depressed), type the port number and press Enter.
-or-
If the display order of your server list is by name or EID number (Name or EID button is
depressed), type the first few characters of the name of the server or the EID number to
establish it as unique and press Enter.
2. To switch back to the previous server, press Print Screen then Backspace.
Navigating the OSCAR Interface
This table describes how to navigate the OSCAR interface using the keyboard and mouse.
Table 3.2: OSCAR Interface Navigation Basics
This Keystroke
Print Screen
Does This
Press Print Screen twice to send the Print Screen keystroke to the currently
selected device.
F1
Opens the Help screen for the current dialog box.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
AutoView 2000 Installer/User Guide
Table 3.2: OSCAR Interface Navigation Basics (Continued)
This Keystroke
Escape
Does This
Closes the current dialog box without saving changes and returns to the previous
one. In the Main dialog box, it closes the OSCAR interface and returns to the flag. In
a message box, it closes the pop-up box and returns to the current dialog box.
Opens dialog boxes, selects or checks options and executes actions when used with
underlined or other designated letters.
Alt+Hotkey
Alt+X
Alt+O
Closes the current dialog box and returns to the previous one.
Selects the OK button, then returns to the previous dialog box.
In a text box, selects the text for editing and enables the Left and Right Arrow keys
to move the cursor. Press Enter again to quit the edit mode.
Single-click, Enter
Enter
Completes a switch in the Main dialog box and exits the OSCAR interface.
Toggles back to previous selection.
Print Screen,
Backspace
Immediately disengages a user from a server; no server is selected. Status flag
displays Free. (This only applies to the 0 on the keyboard and not the keypad.)
Print Screen, Alt+0
Immediately turns on screen saver mode and prevents access to that specific
console, if it is password protected.
Print Screen, Pause
Up/Down Arrows
Right/Left Arrows
Moves the cursor from line to line in lists.
Moves the cursor between columns. When editing a text box, these keys move the
cursor within the column.
Page Up/Page Down
Home/End
Pages up and down through Name and Port lists and Help pages.
Moves the cursor to the top or bottom of a list.
Delete
Deletes current selection in the scan list or characters in a text box.
Deletes from the current selection to the end of the list when editing a scan list.
Pages up and down through Name and Port lists and Help pages.
Type from the keyboard or keypad.
Shift-Del
Page Up/Page Down
Numbers
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
17
Configuring OSCAR Interface Menus
You can configure your AutoView 2000 switch from the Setup menu within the OSCAR interface.
Select the Names button when initially setting up your appliance to identify servers by unique names.
Select the other setup features to manage routine tasks for your servers from the OSCAR
interface menu.
Table 3.3: Setup Features to Manage Routine Tasks for Your Servers
Feature
Menu
Purpose
Change the server listing between numerically by port or EID number and
alphabetically by name. Change the Screen Delay Time before the OSCAR interface
displays after pressing Print Screen.
Flag
Change display, timing, color or location of the status flag.
Set up to simultaneously control multiple servers through keyboard and
mouse actions.
Broadcast
Scan
Set up a custom scan pattern for up to 16 servers.
Security
Devices
Names
Switch
Set passwords to restrict server access. Enable the screen saver.
Identify the appropriate number of ports on an attached cascaded switch.
Identify servers by unique names.
Choose the switch mode and the share mode time-out.
To access the Setup menu:
1. Press Print Screen to launch the OSCAR interface. The Main dialog box displays.
2. Click Setup. The Setup dialog box displays.
Figure 3.2: Setup Dialog Box
Download from Www.Somanuals.com. All Manuals Search And Download.
18
AutoView 2000 Installer/User Guide
Assigning server names
Use the Names dialog box to identify individual servers by name rather than by port number. The
Names list is always sorted by port order. Names are stored in the AVRIQ module, so even if you
move the cable/server to another ARI port, the name and configuration will be recognized by
the switch.
NOTE: If a server is turned off, its respective AVRIQ module will not appear in the Names list.
To access the Names dialog box:
1. Press Print Screen to launch the OSCAR interface. The Main dialog box will appear.
2. Click Setup - Names. The Names dialog box displays.
Figure 3.3: Names Dialog Box
NOTE: If the server list changes, the mouse cursor will turn into an hourglass as the list is automatically updated. No
mouse or keyboard input will be accepted until the list update is complete.
To assign names to servers:
1. In the Names dialog box, select a server name or port number and click Modify. The Name
Modify dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
19
Figure 3.4: Name Modify Dialog Box
2. Type a name in the New Name box. Names of servers may be up to 15 characters long. Legal
characters include: A to Z, a to z, 0 to 9, space and hyphen.
3. Click OK to transfer the new name to the Names dialog box. Your selection is not saved until
you click OK in the Names dialog box.
4. Repeat steps 1 to 3 for each server in the system.
5. Click OK in the Names dialog box to save your changes.
-or-
Click X or press Escape to exit the dialog box without saving changes.
NOTE: If an AVRIQ module has not been assigned a name, the EID is used as the default name.
Assigning device types
The AutoView 2000 switch automatically discovers cascaded KVM switches, but you will need to
specify the number of ports on the cascaded switch through the Devices dialog box. You will see an
Sw-8 or Sw-24 display in the Type category for the cascaded switch. Select the switch from the list
and the Modify button displays, allowing you to assign it the appropriate number of ports.
NOTE: The Modify button will only be available if a configurable switch is selected.
To access the Devices dialog box:
1. Press Print Screen to launch the OSCAR interface. The Main dialog box will appear.
2. Click Setup - Devices. The Devices dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
AutoView 2000 Installer/User Guide
Figure 3.5: Devices Dialog Box
When the AutoView switch discovers a cascaded switch, you will notice the port numbering
change to accommodate each server under that switch. For example, if the switch is connected to
ARI port 6, the switch port would be listed as 06 and each server under it would be numbered
sequentially 06-01, 06-02 and so on.
To assign a device type:
1. In the Devices dialog box, select the desired port number.
2. Click Modify. The Device Modify dialog box displays.
Figure 3.6: Device Modify Dialog Box
3. Choose the number of ports supported by your cascaded switch and click OK.
4. Repeat steps 1 to 3 for each port requiring a device type to be assigned.
5. Click OK in the Devices dialog box to save settings.
NOTE: Changes made in the Device Modify dialog box are not saved until you click OK in the Devices
dialog box.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
21
Changing the display behavior
Use the Menu dialog box to change the display order of servers and set a Screen Delay Time for the
OSCAR interface. The display order setting alters how servers will display in several screens
including the Main, Devices and Broadcast dialog boxes.
To access the Menu dialog box:
1. Press Print Screen to launch the OSCAR interface. The Main dialog box displays.
2. Click Setup - Menu in the Main dialog box. The Menu dialog box displays.
Figure 3.7: Menu Dialog Box
To choose the default display order of servers:
1. Select Name to display servers alphabetically by name.
-or-
Select EID to display servers numerically by EID number.
-or-
Select Port to display servers numerically by port number.
2. Click OK.
To set a Screen Delay Time for the OSCAR interface:
1. Type in the number of seconds (0 to 9) to delay the OSCAR interface display after you press Print
Screen. Entering 0 will instantly launch the OSCAR interface with no delay.
2. Click OK.
Setting a Screen Delay Time allows you to complete a soft switch without the OSCAR interface
displaying. To perform a soft switch, see Soft switching in this chapter.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
AutoView 2000 Installer/User Guide
Controlling the status flag
The status flag displays on your desktop and shows the name or EID number of the selected server
or the status of the selected port. Use the Flag dialog box to configure the flag to display by server
name or EID number, or to change the flag color, opacity, display time and location on the desktop.
Table 3.4: OSCAR Interface Status Flags
Flag
Description
Flag type by name
Flag type by EID number
Flag indicating that the user has been disconnected from all systems
Flag indicating that Broadcast mode is enabled
To access the Flag dialog box:
1. Press Print Screen. The Main dialog box will appear.
2. Click Setup - Flag. The Flag dialog box displays.
Figure 3.8: Flag Dialog Box
To determine how the status flag is displayed:
1. Select Name or EID to determine what information will be displayed.
2. Select Displayed to show the flag all the time or select Timed to display the flag for only five
seconds after switching.
3. Select a flag color in Display Color.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
23
4. In Display Mode, select Opaque for a solid color flag or select Transparent to see the desktop
through the flag.
5. To position the status flag on the desktop:
a. Click Set Position to gain access to the Set Position Flag screen.
b. Left-click on the title bar and drag to the desired location.
c. Right-click to return to the Flag dialog box.
Figure 3.9: Set Position Flag
NOTE: Changes made to the flag position are not saved until you click OK in the Flag dialog box.
6. Click OK to save settings.
-or-
Click X to exit without saving changes.
Setting console security
The OSCAR interface enables you to set security on your analog port console. You can establish a
screen saver mode that engages after your console remains unused for a specified Inactivity Time.
Once engaged, your console will remain locked until you press any key or move the mouse. You
will then need to type in your password to continue.
Use the Security dialog box to lock your console with password protection, set or change your
password and enable the screen saver.
NOTE: If a password has been previously set, you will have to enter the password before you can access the
Security dialog box.
To access the Security dialog box:
1. Press Print Screen to launch the OSCAR interface. The Main dialog box will appear.
2. Click Setup - Security. The Security dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
24
AutoView 2000 Installer/User Guide
Figure 3.10: Security Dialog Box
To set or change the password:
1. Single-click and press Enter or double-click in the New text box.
2. Type the new password in the New text box and press Enter.
Passwords must contain both alpha and numeric characters, are case sensitive and may be up to
12 characters long. Legal characters are: A to Z, a to z, Ø to 9, space and hyphen.
3. In the Repeat box, type the password again and press Enter.
4. Click OK to change only your password, and then close the dialog box.
NOTE: If you should lose or forget your password, please contact Avocent Technical Support about returning
your switch for service. See Appendix C:Technical Support for contact information.
To password protect your console:
1. Set your password as described in the previous procedure.
2. Select Enable Screen Saver.
3. Type the number of minutes for Inactivity Time (from 1 to 99) to delay activation of password
protection and the screen saver feature.
4. For Mode, select Energy if your monitor is ENERGY STAR® compliant; otherwise select Screen
.
CAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant with
ENERGY STAR®.
5. (Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you
to the Security dialog box.
6. Click OK.
To log in to your console:
1. Press any key or move the mouse.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
25
2. The Password dialog box displays. Type your password, then click OK.
3. The Main dialog box displays if the password was entered properly.
To remove password protection from your console:
1. From the Main dialog box, click Setup - Security; the Password dialog box displays. Type your
password, then click OK.
2. In the Security dialog box, single-click and press Enter or double-click in the New box. Leave
the box blank. Press Enter.
3. Single-click and press Enter or double-click in the Repeat box. Leave the box blank.
Press Enter.
4. Click OK to eliminate your password.
To enable the screen saver mode with no password protection:
1. If your console does not require a password to gain access to the Security dialog box, proceed
to step 2.
-or-
If your console is password protected, see the previous procedure, then go to step 2.
2. Select Enable Screen Saver.
3. Type the number of minutes for Inactivity Time (from 1 to 99) to delay activation of the
screen saver.
4. Choose Energy if your monitor is ENERGY STAR® compliant; otherwise select Screen.
CAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant with
ENERGY STAR®.
5. (Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you
to the Security dialog box.
6. Click OK.
NOTE: Activation of the screen saver mode disconnects the user from a server; no server is selected. The status
flag displays Free.
To exit the screen saver mode:
Press any key or move your mouse. The Main dialog box displays and any previous server
connection will be restored.
Download from Www.Somanuals.com. All Manuals Search And Download.
26
AutoView 2000 Installer/User Guide
To turn off the screen saver:
1. In the Security dialog box, clear Enable Screen Saver.
2. Click OK.
To immediately turn on the screen saver:
Press Print Screen, then press Pause.
Displaying Version Information
The OSCAR interface enables you to display the versions of the AutoView 2000 switch and the
AVRIQ module firmware. For optimum performance, keep your firmware current. For more
information, see Appendix A.
To display version information:
1. Press Print Screen. The Main dialog box will appear.
2. Click Commands - Display Versions. The Version dialog box displays. The top half of the box
lists the subsystem versions in the appliance.
Figure 3.11: Version Dialog Box
3. Click the AVRIQ button to view individual AVRIQ module version information.The AVRIQ
Selection dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
27
Figure 3.12: AVRIQ Selection Dialog Box
4. Select an AVRIQ module to view and click the Version button. The AVRIQ Version dialog
box displays. For more information on loading firmware, see Appendix A.
Figure 3.13: AVRIQ Version Dialog Box
5. Click X to close the AVRIQ Version dialog box.
Scanning Your System
In scan mode, the appliance automatically scans from port to port (server to server). You can scan
up to 16 servers, specifying which servers to scan and the number of seconds that each server will
display. The scanning order is determined by placement of the server in the list. The list is always
shown in scanning order. You can, however, choose to display the server’s name or EID number by
pressing the appropriate button.
Download from Www.Somanuals.com. All Manuals Search And Download.
28
AutoView 2000 Installer/User Guide
To add servers to the scan list:
1. If the OSCAR interface is not open, press Print Screen. The Main dialog box will appear.
2. Click Setup - Scan. The Scan dialog box displays.
Figure 3.14: Scan Dialog Box
3. The dialog box contains a listing of all servers attached to your appliance. Click the checkbox
next to the servers you wish to scan.
-or-
Double-click on a server’s name or port.
-or-
Press Alt and the number of the server you wish to scan. You can select up to 16 servers from the
entire list.
4. In the Scan Time box, type the number of seconds (from 3 to 99) of desired time before the
scan moves to the next server in the sequence.
5. Click OK.
To remove a server from the scan list:
1. In the Scan dialog box, deselect the checkbox next to the server to be removed.
-or-
Double-click on the server’s name or port.
-or-
Click the Clear button to remove all servers from the scan list.
2. Click OK.
To start the scan mode:
1. If the OSCAR interface is not open, press Print Screen. The Main dialog box will appear.
2. Click Commands. The Commands dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
29
Figure 3.15: Commands Dialog Box
3. Select Scan Enable in the Commands dialog box.
4. Click X to close the Commands dialog box.
NOTE: Scanning will begin when the Main dialog box or flag is displayed. Scanning is inhibited in any other
OSCAR interface dialog box.
To cancel scan mode:
1. Select a server if the OSCAR interface is open.
-or-
Move the mouse or press any key on the keyboard if the OSCAR interface is not open.
Scanning will stop at the currently selected server.
-or-
Press Print Screen. The Main dialog box will appear.
2. Click Commands. The Commands dialog box displays.
3. Clear Scan Enable.
Running System Diagnostics
You can validate the integrity of your system through the Run Diagnostics command. This command
checks the main board functional sub-systems (memory, communications, switch control and the
video channels) for each system controller. When you select the Run Diagnostics option, you will
receive a warning indicating that all users (remote and local) will be disconnected. Click OK to
confirm and begin the test.
The Diagnostics dialog box displays. The top section of the dialog box displays the hardware tests.
The bottom portion divides the tested AVRIQ modules into three categories: On-line, Offline
or Suspect.
NOTE: An AVRIQ module may appear to be offline while it is being upgraded.
Download from Www.Somanuals.com. All Manuals Search And Download.
30
AutoView 2000 Installer/User Guide
Figure 3.16: Diagnostics Dialog Box
Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to
the left of each item as that test finishes. The following table details each of the tests.
Table 3.5: Diagnostic Test Details
Test
Description
Memory Tests
Reports on the condition of the main board RAM
Reports on the condition of the main board RAM
Firmware CRCs
Comm Interfaces
Switch Controller test
Validates the current firmware images stored in the system’s FLASH
Verifies the switch matrix controller is accessible and functional
Indicates the condition of the local video monitor
Local Video
Indicates the total number of currently connected and powered AVRIQ modules
On-line AVRIQ modules
Indicates the number of AVRIQ modules that have been connected successfully
in the past and are powered down
Offline AVRIQ modules
Suspect AVRIQ modules
Indicates the number of AVRIQ modules that have been detected, but are either
unavailable for connection or have dropped packets during the ping tests
To run diagnostic tests:
1. If the OSCAR interface is not open, press Print Screen. The Main dialog box will appear.
2. Click Commands - Run Diagnostics. A warning message displays indicating that all users will
be disconnected.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
31
Figure 3.17: Diagnostics Warning Dialog Box
3. Click OK to begin diagnostics.
-or-
Click X or press Escape to exit the dialog box without running a diagnostic test.
4. All users are disconnected and the Diagnostics dialog box displays.
5. As each test is finished, a pass (green circle) or fail (red x) symbol displays. The test is com-
plete when the last test’s symbol displays.
Broadcasting to Servers
The analog user can simultaneously control more than one server in a system to ensure that all
selected servers receive identical input. You can choose to broadcast keystrokes and/or mouse
movements independently.
NOTE: You can broadcast to up to 16 servers at a time, one server per ARI port.
To access the Broadcast dialog box:
1. Press Print Screen. The Main dialog box will appear.
2. Click Setup - Broadcast. The Broadcast dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
32
AutoView 2000 Installer/User Guide
Figure 3.18: Broadcast Dialog Box
NOTE: Broadcasting Keystrokes - The keyboard state must be identical for all servers receiving a broadcast to
interpret keystrokes identically. Specifically, the Caps Lock and Num Lock modes must be the same on all
keyboards. While the appliance attempts to send keystrokes to the selected servers simultaneously, some servers
may inhibit and thereby delay the transmission.
NOTE: Broadcasting Mouse Movements - For the mouse to work accurately, all systems must have identical
mouse drivers, desktops (such as identically placed icons) and video resolutions. In addition, the mouse must be
in exactly the same place on all screens. Because these conditions are extremely difficult to achieve,
broadcasting mouse movements to multiple systems may have unpredictable results.
To broadcast to selected servers:
1. From the Broadcast dialog box, select the mouse and/or keyboard checkboxes for the servers
that are to receive the broadcast commands.
-or-
Press the Up or Down Arrow keys to move the cursor to the target server. Then press Alt+K to
select the keyboard checkbox and/or Alt+M to select the mouse checkbox. Repeat for
additional servers.
2. Click OK to save the settings and return to the Setup dialog box. Click X or press Escape to
return to the Main dialog box.
3. Click Commands. The Commands dialog box displays.
4. Click the Broadcast Enable checkbox to activate broadcasting. The Broadcast Enable
Confirm/Deny dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3: Basic Operations
33
Figure 3.19: Broadcast Enable Confirm/Deny Dialog Box
5. Click OK to enable the broadcast. Click X or press Escape to cancel and return to the Com-
mands dialog box.
6. If broadcasting is enabled, type the information and/or perform the mouse movements you
want to broadcast from the user station. Only servers in the list are accessible.
NOTE: The other user is disabled when broadcast mode is enabled.
To turn broadcasting off:
From the Commands dialog box, clear the Broadcast Enable checkbox.
Changing Your Switch Mode
Your AutoView 2000 switch allows you to connect to attached servers using two methods:
Preemptive and Cooperative.
Select Preemptive (default setting) to allow any user to select any server at any time; a request from
another user disconnects the current user without warning.
-or-
Select Cooperative to maintain the current user connection; the current user will not be
disconnected if another user requests connection.
To access the Switch dialog box:
1. Press Print Screen. The Main dialog box will display.
2. Click Setup-Switch. The Switch dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
35
APPENDICES
Appendices
Appendix A: FLASH Upgrades
Upgrading the AutoView 2000 switch
You can upgrade the firmware of your AutoView 2000 switch by using a special update utility
provided by Avocent. This utility automatically configures the port communications settings to
allow direct downloading from the connected server.
Items needed for the upgrade
•
•
•
•
Server running Windows NT®, Windows® 95, Windows 98 or Windows 2000
Available serial port (COM port) on the server
Null modem serial cable (DB-male) that connects the switch and the server
Firmware update
To upgrade firmware:
1. Connect the standard serial cable to a COM port on the server and to the serial connector on the
back panel of the switch. Make a note of which COM port you have chosen, then turn on
the switch.
2. Go to http://www.avocent.com/support and click on product upgrades to access the firmware
upgrade file. Once the download is complete, navigate to the drive where you have saved the
firmware update and unzip the file.
3. Double-click to run the file WUpDateAVO.exe.
4. In the dialog box that displays, select the desired language and COM port.
5. Click Load.
6. Once the firmware is updated, the following message displays Download complete. Click
Done to exit the dialog box.
7. The switch automatically reboots after the upgrade is completed.
Possible error conditions
If the download does not execute properly, verify the following:
•
•
Verify that the COM port is correct.
Verify that no other program is currently using the COM port, or that no previous DOS win-
dow/shell is open that had used the desired COM port.
•
•
Verify that no other copies of the WUpDate utility are currently running.
Verify that a null modem serial cable is used.
Download from Www.Somanuals.com. All Manuals Search And Download.
36
AutoView 2000 Installer/User Guide
•
In the selected COM port Advanced Port settings, verify that the FIFO buffers are selected and
that the receive buffer is set to High.
CAUTION: While upgrading, do not use your computer for anything else or switch between windows. Close all
other windows if necessary. If the upgrade was unsuccessful (such as during a power outage), repeat
the procedure.
Upgrading the AVRIQ module firmware
The AVRIQ modules can be upgraded individually or simultaneously.
To simultaneously upgrade multiple AVRIQ modules:
1. Press Print Screen. The Main dialog box will appear.
2. Click Commands - AVRIQ Status. The AVRIQ Status dialog box displays.
Figure A.1: AVRIQ Status Dialog Box
3. Click one or more types of modules to upgrade. Click Upgrade.
4. The AVRIQ Upgrade dialog box displays. Click OK to initiate the upgrade and return to the
AVRIQ Status dialog box.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendices
37
Figure A.2: AVRIQ Upgrade Dialog Box
To upgrade AVRIQ module firmware individually:
1. Press Print Screen. The Main dialog box will appear.
2. Click Commands - Display Versions. The Version dialog box displays.
Figure A.3: Version Dialog Box
3. Click AVRIQ to view individual AVRIQ module version information. The AVRIQ Selection
dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
38
AutoView 2000 Installer/User Guide
Figure A.4: AVRIQ Selection Dialog Box
4. Select an AVRIQ module to upgrade and click the Version button. The AVRIQ Version dialog
box displays.
Figure A.5: AVRIQ Version Dialog Box
5. Click the Load Firmware button. The AVRIQ Load dialog box displays.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendices
39
Figure A.6: AVRIQ Load Dialog Box
6. Click OK to initiate the upgrade and return to the Status dialog box.
NOTE: During an upgrade, the AVRIQ status indicator in the Main dialog box will be yellow. The AVRIQ module
is unavailable while an upgrade is in progress. When an upgrade is initiated, any current connection to the server
via the AVRIQ module will be terminated.
Download from Www.Somanuals.com. All Manuals Search And Download.
40
AutoView 2000 Installer/User Guide
Appendix B: Technical Specifications
Table B.1: Product Specifications
AutoView 2000 Switch Product Specifications
Server Ports
Number
Types
16
PS/2, Sun, USB and serial AVRIQ modules
RJ-45
Connectors
Sync Types
Plug and Play
Video Resolution
Update Port
Number
Separate horizontal and vertical
DDC2B
Analog Port Maximum 1600 x 1280 @ 75 Hz
2
Type
Serial RS-232
DB9 Male
Connector
Analog Port Sets
Number
2
Type
PS/2, VGA and ACI
Connectors
Dimensions
PS/2 miniDIN, 15 pin D, RJ-45
Dimensions
(H x W x D)
4.45 x 43.18 x 27.94 cm 1U form factor (1.75 x 17.00 x 11.00 in.)
Weight
3.6 kg (8 lb) without cables
Heat Dissipation
Airflow
92 BTU/Hr
8 cfm
Power
12.5 W
Consumption
AC-input power
40 W maximum
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendices
41
Table B.1: Product Specifications (Continued)
AutoView 2000 Switch Product Specifications
AC-input
100 to 240 VAC Autosensing
voltage rating
AC-input current
rating
0.5 A
AC-input cable
18 AWG three-wire cable, with a three-lead IEC-320 receptacle on the power supply
end and a country or region dependent plug on the power resource end
AC-frequency
Temperature
50/60 HZ
o
o
o
o
10 to 50 Celsius (50 to 122 Farenheit) operating
o
o
o
o
-20 to 60 Celsius (-4 to 140 Farenheit) nonoperating
Humidity
20 to 80% noncondensing operating
5 to 95% noncondensing nonoperating
Safety and EMC Approvals and Markings
UL, FCC, cUL, ICES, CE, N, GS, IRAM, GOST, VCCI, MIC, C-Tick
Download from Www.Somanuals.com. All Manuals Search And Download.
42
AutoView 2000 Installer/User Guide
Appendix C: Technical Support
Our Technical Support staff is ready to assist you with any installation or operating issues you
encounter with your Avocent product. If an issue should develop, follow the steps below for the
fastest possible service.
To resolve an issue:
1. Check the pertinent section of this manual to see if the issue can be resolved by following the
procedures outlined.
2. Check our web site at www.avocent.com/support to search the knowledge base or use the on-
line service request.
3. Call the Avocent Technical Support location nearest you.
Download from Www.Somanuals.com. All Manuals Search And Download.
43
INDEX
Index
A
adding legacy switches 10
ARI port 13
AutoView 2000 switch
adding legacy switches 10
cascading 1, 8
DDC Plug and Play 2
E
features 1
installing bracket 6
rack loading 6
supplied with 5
Flag dialog box 22
FLASH upgrading 2, 35
AVRIQ module 1
connecting to server 7
upgrading 36
K
AVRIQ Selection dialog box 27
Keep Alive 1
B
L
Broadcast dialog box 32
Broadcast Enable dialog box 33
broadcasting off 33
legacy switches 10
M
Menu dialog box 21
C
N
cascading 2, 8
Name Modify dialog box 19
Names dialog box 18
navigating the OSCAR interface 15
CAT 5 1
changing password 24
Commands dialog box 29
configuring OSCAR interface menus 17
console security 23
O
operation modes 2
OSCAR interface 2, 13
OutLook switch 2
Download from Www.Somanuals.com. All Manuals Search And Download.
44
AutoView 2000 Installer/User Guide
P
password protecting 24
R
rack mounting 5
rack mounting safety 4
removing password protection 25
Switch dialog box 34
switch mode
S
safety precautions 3
Scan dialog box 28
scanning system 27
screen saver
changing 33
switch mounting bracket 6
system diagnostics 29
T
turning off 26
technical support 42
Security dialog box 24
server status 14
V
servers
Version dialog box 26
VGA video 2
adding to scan list 28
assigning names 18
broadcasting to 31
configuring for soft switching 15
disconnecting from 15
selecting 14
X
XGA video 2
soft switching to a server 15
viewing and selecting 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
AutoView 2000
Guide d’installation et d’utilisation
Avocent, le logo Avocent, The Power of Being There, AutoView et
OSCAR sont des marques déposées d’Avocent Corporation ou de ses
filiales. Toutes les autres marques sont la propriété exclusive de leurs
détenteurs respectifs.
2004 Avocent Corporation. Tous droits réservés.
590-284-116C
Download from Www.Somanuals.com. All Manuals Search And Download.
Notification pour les États-Unis
Avertissement : Les modifications apportées à ce produit sans l’accord exprès de la partie responsable de la
conformité peuvent annuler l’autorisation dont vous bénéficiez pour utiliser cet équipement.
Nota : L’équipement a été testé et déclaré conforme aux limites définies pour les appareils numériques de
classe A, suivant l’article 15 du règlement de la FCC. Ces limites garantissent une protection suffisante contre
les effets dangereux liés à l’utilisation de l’équipement dans un environnement professionnel. L’appareil
génère, utilise et peut émettre des ondes de radiofréquence et, s’il n’est pas installé et utilisé conformément au
manuel d’instructions, peut provoquer de dangereuses interférences avec les communications radio. Lors de
l’utilisation de l’appareil dans une zone d’habitation, il est probable que des interférences dangereuses soient
provoquées, auquel cas vous devez y remédier à vos propres frais.
Notification canadienne
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set
out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le
Ministère des Communications du Canada.
Notification japonaise
Agréments et labels de sécurité et EMC
UL, FCC, cUL, ICES, CE, N, GS, IRAM, GOST, VCCI, MIC, C-Tick
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE DES MATIÈRES
Liste des figures .............................................................................................................. v
Liste des tableaux.......................................................................................................... vii
Chapitre 1: Présentation du produit............................................................................... 1
Caractéristiques et avantages ............................................................................................................1
Le module intelligent AVRIQ .............................................................................................................1
Mesures de sécurité............................................................................................................................3
Chapitre 2: Installation .................................................................................................... 5
Démarrage .........................................................................................................................................5
Éléments livrés avec le commutateur AutoView 2000 ................................................................5
Montage en rack du commutateur AutoView 2000 ............................................................................5
Installation du commutateur AutoView 2000.....................................................................................6
Configuration en cascade de commutateurs AutoView 2000.............................................................8
Ajout de commutateurs classiques ...................................................................................................10
Configuration du système de commutation AutoView 2000.............................................................11
Chapitre 3: Opérations de base.................................................................................... 13
Contrôle du système par les voies analogiques ...............................................................................13
Visualisation et sélection des voies et des serveurs .........................................................................13
Navigation dans l’interface OSCAR ................................................................................................15
Fonctions de configuration de l’interface OSCAR ..........................................................................17
Attribution de noms aux serveurs..............................................................................................18
Assignation des types d’équipement : .......................................................................................19
Modification de l’affichage.......................................................................................................21
Contrôle de l’indicateur d’état .................................................................................................22
Paramétrage de sécurité de la console.....................................................................................23
Affichage des informations relatives à la version ............................................................................26
Balayage du système ........................................................................................................................27
Diagnostic du système......................................................................................................................29
Diffusion vers les serveurs ...............................................................................................................31
Modification du mode de commutation............................................................................................33
Download from Www.Somanuals.com. All Manuals Search And Download.
iv
AutoView 2000 Guide d’installation et d’utilisation
Annexes .......................................................................................................................... 35
Annexe A : Mises à jour FLASH ......................................................................................................35
Annexe B : Spécifications techniques...............................................................................................40
Annexe C : Assistance technique......................................................................................................42
Index................................................................................................................................ 43
Download from Www.Somanuals.com. All Manuals Search And Download.
v
LISTE DES FIGURES
Liste des figures
Figure 1.1 : Commutateur AutoView 2000........................................................................................1
Figure 1.2 : Exemple de configuration du commutateur AutoView 2000..........................................3
Figure 2.1 : Installation horizontale du commutateur AutoView 2000 .............................................6
Figure 2.2 : Configuration de base du commutateur AutoView 2000 ...............................................7
Figure 2.3 : Configuration du commutateur AutoView 2000 avec un commutateur
en cascade......................................................................................................................9
Figure 2.4 : Configuration du commutateur AutoView 2000 avec un commutateur
KVM classique.............................................................................................................10
Figure 3.1 : Exemple de boîte de dialogue Main (Principal) configurée........................................13
Figure 3.2 : Boîte de dialogue Setup (Configuration) .....................................................................17
Figure 3.3 : Boîte de dialogue Names (Noms).................................................................................18
Figure 3.4 : Boîte de dialogue Name Modify (Modifier nom) ........................................................19
Figure 3.5 : Boîte de dialogue Devices (Équipements) ...................................................................20
Figure 3.6 : Boîte de dialogue Device Modify (Modif. équip.)........................................................20
Figure 3.7 : Boîte de dialogue Menu ...............................................................................................21
Figure 3.8 : Boîte de dialogue Flag (Indicateur) ............................................................................22
Figure 3.9 : Set Position (Fixer position) ........................................................................................23
Figure 3.10 : Boîte de dialogue Security (Sécurité) ........................................................................24
Figure 3.11 : Boîte de dialogue Version..........................................................................................26
Figure 3.12 : Boîte de dialogue AVRIQ Selection (Sélection AVRIQ) ............................................27
Figure 3.13 : Boîte de dialogue AVRIQ Version (Version AVRIQ).................................................27
Figure 3.14 : Boîte de dialogue Scan (Balayage)............................................................................28
Figure 3.15 : Boîte de dialogue Commands (Commandes).............................................................29
Figure 3.16 : Boîte de dialogue Diagnostics ...................................................................................30
Figure 3.17 : Boîte de dialogue Diagnostics Warning (Avertissement diagnostics).......................31
Figure 3.18 : Boîte de dialogue Broadcast (Diffusion) ...................................................................32
Figure 3.19 : Boîte de dialogue Broadcast Enable Confirm/Deny
(Activer/Désactiver la diffusion) ...............................................................................33
Figure 3.20 : Boîte de dialogue Switch (Commutateur).................................................................34
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
AutoView 2000 Guide d’installation et d’utilisation
Figure A.1 : Boîte de dialogue AVRIQ Status (État de l’AVRIQ) ..................................................36
Figure A.2 : Boîte de dialogue AVRIQ Upgrade (Mise à jour de l’AVRIQ) ..................................37
Figure A.3 : Boîte de dialogue Version ..........................................................................................37
Figure A.4 : Boîte de dialogue AVRIQ Selection (Sélection AVRIQ).............................................38
Figure A.5 : Boîte de dialogue AVRIQ Version (Version AVRIQ) .................................................38
Figure A.6 : Boîte de dialogue AVRIQ Load (Chargement AVRIQ) ..............................................39
Download from Www.Somanuals.com. All Manuals Search And Download.
vii
LISTE DES TABLEAUX
Liste des tableaux
Tableau 2.1 : Compatibilité avec les commutateurs classiques...................................................10
Tableau 3.1 : Symboles d’état utilisés dans l’interface OSCAR..................................................14
Tableau 3.2 : Concepts de base de la navigation dans OSCAR ..................................................15
Tableau 3.3 : Fonctions de configuration pour gérer les tâches de routine des serveurs...........17
Tableau 3.4 : Indicateurs d’état de l’interface OSCAR...............................................................22
Tableau 3.5 : Détails des tests de diagnostic...............................................................................30
Tableau B.1 : Spécifications Produit ...........................................................................................40
Download from Www.Somanuals.com. All Manuals Search And Download.
viii
AutoView 2000 Guide d’installation et d’utilisation
Download from Www.Somanuals.com. All Manuals Search And Download.
1
CHAPITRE
Présentation du produit
1
Caractéristiques et avantages
Le commutateur AutoView® 2000 utilisateurs multiples à 16 voies intègre la technologie Avocent
de commutation analogique KVM (Keyboard, Video, Mouse) avec une fonctionnalité de gestion de
câble avancée, un accès flexible pour une utilisation simultanée par deux utilisateurs et une
interface utilisateur brevetée de nouvelle génération. Il est compatible avec les principales plate-
formes de serveurs et est doté d’une puissante fonctionnalité de gestion à l’écran facilitant la
configuration du système et la sélection des serveurs.
L’un des avantages spécifiques au commutateur AutoView 2000 est le module intelligent AVRIQ.
Le module AVRIQ de conception CAT5 réduit de façon significative l’encombrement dû aux
câbles tout en optimisant la résolution et les réglages vidéo. La mémoire intégrée du module
AVRIQ simplifie la configuration en attribuant à chaque serveur relié un nom et un numéro
d’identification électronique (EID) unique. Le module AVRIQ est alimenté directement par le
serveur et offre la fonction Keep Alive même si le commutateur AutoView n’est pas alimenté.
Figure 1.1 : Commutateur AutoView 2000
Le module intelligent AVRIQ
Les modules AVRIQ permettent une connectivité KVM directe aux serveurs depuis le
commutateur AutoView. Chaque commutateur AutoView 2000 est doté de 16 voies ARI
(Interface en rack d’Avocent) pour la connexion de modules AVRIQ.
L’utilisation d’un module AVRIQ vous permet de relier des commutateurs supplémentaires pour
étendre votre système de commutateurs AutoView. Cette expansion vous permet d’augmenter la
capacité du système au fur et à mesure de la croissance de votre centre de données.
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Guide d’installation et d’utilisation du commutateur AutoView 2000
Compatibilité des multi-plateformes
Les modules AVRIQ disponibles avec le commutateur AutoView 2000 sont compatibles avec les envi-
ronnements de serveurs PS/2, Sun™ et USB. L’utilisation de l’interface graphique utilisateur OSCAR®
en combinaison avec ces modules de câblage vous permet de passer aisément d’une plate-forme à l’autre.
Interface graphique utilisateur OSCAR
Le commutateur AutoView 2000 fonctionne avec OSCAR, l’interface graphique utilisateur
intuitive qui vous permet de configurer votre système et de sélectionner les ordinateurs. Les
ordinateurs peuvent être identifiés par nom, par numéro EID ou numéro de voie, ce qui vous permet
ainsi d’attribuer un nom unique à chaque serveur.
Sécurité
L’interface OSCAR vous permet de protéger l’ensemble de votre système grâce au mot de passe de
l’économiseur d’écran. Après une certaine période d’inactivité, dont la durée est définie par
l’utilisateur, le mode d’économiseur d’écran se lance et l’accès au système est alors protégé jusqu’à
la saisie du mot de passe.
Mode de fonctionnement
L’interface utilisateur OSCAR offre des modes de fonctionnement pratiques pour l’administration
simple du commutateur AutoView 2000. Ces différents modes (Broadcast [Diffusion], Scan
[balayage], Switch [Commutation] et Share [Partage]) vous permettent de gérer vos activités de
commutation. Le chapitre 3 explique en détail ces différents modes.
Vidéo
Le commutateur AutoView 2000 offre une résolution vidéo optimale pour les formats vidéo
analogiques VGA, SVGA et XGA. La résolution peut atteindre 1 600 x 1 200 avec un câble de
3 mètres environ et 800 x 600 avec un câble de 15 mètres. Elle varie en fonction de la longueur de
câble séparant le commutateur et les serveurs.
Plug and Play
Le commutateur AutoView 2000 est également conforme au standard d’affichage « Plug and Play »
VESA DDC2B qui automatise la configuration de l’écran.
Mise à jour FLASH
Vous pouvez mettre à jour votre firmware à tout moment à l’aide d’un utilitaire de mise à jour
simple, vous garantissant de toujours utiliser la dernière version disponible. Ce type de mise à jour
est disponible pour le commutateur AutoView 2000 et les modules AVRIQ. Reportez-vous à
l’Annexe A pour de plus amples informations.
Montage en cascade
Chaque commutateur AutoView 2000 permet de relier jusqu’à 16 serveurs et peut facilement être
modifié pour en accommoder un plus grand nombre. Vous pouvez ainsi étendre votre système en
utilisant des produits Avocent montables en cascade, tels les commutateurs AutoView ou OutLook®.
Il vous est alors possible de connecter jusqu’à 256 serveurs sur un seul système. Pour de plus amples
informations, reportez-vous au chapitre 2.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 1: Présentation du produit
3
Commutateur AutoView
2000 (monté en cascade)
Commutateur classique
(monté en cascade)
Rack de serveurs
Module
AVRIQ
Serveur critique
Connexion
analogique
Commutateur
AutoView 2000
(principal)
Connexion
analogique
Figure 1.2 : Exemple de configuration du commutateur AutoView 2000
Mesures de sécurité
Afin d’éviter d’éventuels problèmes de vidéo ou de clavier lors de l’utilisation des produits
Avocent, prenez les précautions suivantes :
•
Si le bâtiment est alimenté en courant alternatif triphasé, assurez-vous que l’ordinateur et le
moniteur sont sur la même phase. Pour des résultats optimaux, ils doivent se trouver sur le
même circuit.
•
Utilisez uniquement des câbles fournis par Avocent pour connecter les ordinateurs aux
commutateurs KVM. La garantie d’Avocent ne s’applique pas en cas de dommages liés à
l’utilisation de câbles autres que ceux fournis par Avocent.
Afin d’éviter tout risque de choc mortel et tout dommage matériel, prenez les précautions suivantes :
•
•
•
N’utilisez jamais de rallonge à 2 fils avec les produits Avocent.
Vérifiez la polarité et la mise à la terre des prises de courant alternatif de l’ordinateur et du moniteur.
Utilisez uniquement des prises de courant reliées à la terre, pour l’ordinateur et le moniteur.
Lors de l’utilisation d’une alimentation de secours (sans coupure), mettez sur le même réseau
l’ordinateur, le moniteur et le commutateur AutoView 2000.
NOTA : La meilleure façon de mettre l’équipement hors tension est de le débrancher de la prise de courant.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Guide d’installation et d’utilisation du commutateur AutoView 2000
Sécurité relative au montage en rack
•
Température ambiante élevée : Si l’équipement se trouve en rack fermé, il se peut que la
température de fonctionnement du rack soit supérieure à la température ambiante de la pièce.
Veillez à ce que cette température n’excède pas la température maximale de fonctionnement du
matériel.
•
•
•
Circulation d’air réduite : L’équipement doit être monté en rack de façon à maintenir une
circulation d’air suffisante pour garantir un fonctionnement en toute sécurité.
Charge mécanique : L’équipement doit être monté dans le rack de façon à garantir la bonne
répartition des charges mécaniques et à éviter tout danger.
Surcharge du circuit : Il est important d’effectuer correctement le raccordement du dispositif
au circuit d’alimentation en prêtant une attention particulière à l’impact d’un circuit surchargé
sur la protection contre la surintensité et aux risques qu’il présente pour le câblage
d’alimentation. Tenez compte de la charge maximale spécifiée sur la plaque signalétique.
•
Mise à la terre : La mise à la terre du dispositif monté en rack doit être respectée. Vérifiez en
particulier les branchements autres que les branchements directs au circuit de dérivation
(lors de l’utilisation de barrettes de connexion, par exemple).
Download from Www.Somanuals.com. All Manuals Search And Download.
5
CHAPITRE
Installation
2
Démarrage
Avant d’installer le commutateur AutoView 2000, consultez la liste ci-dessous pour vous assurer
que vous disposez de tous les éléments livrés avec le matériel ainsi que des autres éléments
nécessaires à l’installation.
Éléments livrés avec le commutateur AutoView 2000
•
•
•
•
•
•
Commutateur AutoView 2000
Un cordon d’alimentation
Un cable série null modem direct
Un kit de montage en rack
Le guide d’installation et d’utilisation du commutateur AutoView 2000
Le guide d’installation rapide du commutateur AutoView 2000
Autres éléments nécessaires
Un module AVRIQ et un câble UTP par serveur ou commutateur relié
Montage en rack du commutateur AutoView 2000
Vous pouvez monter votre commutateur AutoView 2000 en rack à l’aide des supports du kit de
montage. Avant l’installation du commutateur et des autres composants dans le rack (s’ils ne sont
pas déjà installés), placez le rack à son emplacement définitif. Commencez toujours l’installation
des composants par le bas du rack. Répartissez la charge et ne dépassez pas la capacité maximale de
stockage du rack.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Guide d’installation et d’utilisation du commutateur AutoView 2000
Figure 2.1 : Installation horizontale du commutateur AutoView 2000
ATTENTION : Chargement du rack : Une mauvaise répartition de la charge ou une surcharge risque d’affaiblir
le rack et de faire plier les étagères, entraînant d’éventuels dommages matériels et corporels. Stabilisez les
racks à leur emplacement définitif avant de les charger. Montez les équipements dans le rack du bas vers le
haut. Ne dépassez pas la charge autorisée.
Installation du support de montage 1U du commutateur
1. Déposez le deux premières vis situées de chaque côté.
2. Alignez les perforations du « côté long » des supports de montage latéraux sur les trous de vis
du commutateur.
3. À l’aide d’un tournevis cruciforme, fixez les supports de montage sur le commutateur au
moyen de deux vis par côté.
4. Fixez les quatre écrous à cage ou de serrage à l’embase de montage du rack, de sorte que
l’écrou soit positionné à l’intérieur du rack.
NOTA : Les écrous ne sont pas inclus dans le kit de montage en rack.
5. Montez le commutateur sur l’étagère à rack en alignant les perforations du « côté court » de
chaque support sur les perforations correspondantes situées sur l’étagère à rack. Insérez ensuite
les vis à tête hexagonale mixte dans les trous du support et dans les trous du rail de montage,
puis dans les écrous à cage ou de serrage.
Installation du commutateur AutoView 2000
Branchez le cordon d’alimentation fourni à l’arrière du matériel, puis à une source d’alimentation
adaptée. La figure 2.2 illustre une configuration possible du commutateur AutoView 2000.
Reportez-vous aux instructions détaillées qui suivent afin d’installer correctement votre matériel.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 2: Installation
7
ATTENTION : Pour éviter d’endommager votre matériel et écarter tout risque d’électrocution :
- Ne retirez pas la prise de terre. Cette prise est un élément de sécurité essentiel.
- Branchez le cordon d’alimentation à une prise reliée à la terre et facilement accessible à tout moment.
- Coupez l’alimentation de l’unité en débranchant le cordon d’alimentation au niveau de la prise ou directement
sur l’unité.
Utilisateur analogique B
Voie de configuration
(pour la mise à jour
du firmware)
Commutateur AutoView 2000
Serveurs 2 à 16
Utilisateur analogique A
Module AVRIQ
Serveur 1
Figure 2.2 : Configuration de base du commutateur AutoView 2000
Connexion d’un module AVRIQ à chaque serveur
1. Repérez les modules AVRIQ du matériel AutoView 2000.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Guide d’installation et d’utilisation du commutateur AutoView 2000
2. Branchez les connecteurs clavier, moniteur et souris du câble aux voies correspondantes du
premier serveur à relier au commutateur en vous aidant du code couleur.
3. Branchez une extrémité du câble CAT 5 qui doit relier le module AVRIQ et le commutateur
AutoView 2000 au connecteur RJ-45 du module AVRIQ.
4. Reliez l’autre extrémité du câble CAT 5 à la voie ARI souhaitée à l’arrière du commutateur
AutoView.
5. Répétez les étapes 2 à 4 pour tous les serveurs que vous souhaitez relier.
NOTA : Lors de la connexion d’un module AVRIQ Sun, utilisez un moniteur à synchronisation multiple pour
prendre en compte les ordinateurs Sun compatibles à la fois avec la norme VGA et les synchronisations sur le
vert ou composites.
Connexion de périphériques locaux
1. Sélectionnez le clavier, le moniteur et la souris à connecter à l’utilisateur analogique local A.
2. Localisez le groupe de voies marqué A à l’arrière de l’équipement. Connectez les
périphériques aux voies correspondantes.
3. Répétez ces étapes pour le groupe de voies analogiques marqué B à l’arrière de l’équipement.
4. Rassemblez et étiquetez les câbles afin de faciliter leur identification.
Configuration en cascade de commutateurs AutoView 2000
Vous pouvez monter en cascade plusieurs commutateurs AutoView 2000 afin de permettre à un ou
deux utilisateur(s) de se connecter jusqu’à 256 serveurs. Dans un système en cascade, chaque voie
ARI (Avocent Rack Interface) du commutateur AutoView 2000 principal est connectée à une voie
ACI (Avocent Console Interface) d’un commutateur AutoView 2000 monté en cascade. Chacun
des commutateurs montés en cascade peut ensuite être relié à un serveur à l’aide d’un module
AVRIQ. L’exemple de la figure 2.3 montre un commutateur AutoView 2000 monté en cascade sur
un commutateur principal, permettant ainsi la connexion de 15 serveurs primaires et 16 serveurs
secondaires. En utilisant cette configuration, vous pouvez relier 16 commutateurs AutoView 2000
au commutateur principal, permettant ainsi d’y relier jusqu’à 256 serveurs. Cette configuration ne
permet qu’un niveau de montage en cascade ; vous ne pouvez par conséquent pas relier de
commutateurs classiques supplémentaires ou d’autres commutateurs AutoView 2000. Dans cette
configuration, la voie locale de l’interface OSCAR est désactivée lorsque le commutateur
AutoView 2000 est mis en cascade sous un autre équipement.
NOTA : Comme illustré sur la figure 2.3, seule la voie analogique ACI sur la console de l’utilisateur local A peut
être utilisée pour le montage en cascade.
Montage en cascade de plusieurs commutateurs AutoView 2000
1. Connectez le commutateur AutoView 2000 en cascade à chaque serveur selon la procédure
décrite à la section précédente Installation du commutateur AutoView 2000.
2. Connectez les périphériques locaux à la console de l’utilisateur local A du commutateur
principal, comme décrit à la section Connexion de périphériques locaux.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 2: Installation
9
3. Connectez une extrémité du câble CAT 5, reliant le commutateur monté en cascade au
commutateur AutoView principal, à la voie RJ-45 (ACI) de l’utilisateur analogique A sur le
commutateur AutoView monté en cascade.
4. Reliez l’autre extrémité du câble CAT 5 à l’une des 16 voies RJ-45 (ARI) du commutateur
AutoView 2000 principal.
NOTA : Le système reconnaît les deux commutateurs en cascade comme un seul ensemble. Tous les serveurs
connectés au commutateur monté AutoView 2000 s’affichent dans la liste de serveurs de l’interface OSCAR du
commutateur de consoles principal.
5. Répétez les étapes 3 et 4 pour tout commutateur AutoView 2000 supplémentaire (secondaire)
monté en cascade que vous souhaitez relier à l’ensemble du système.
Utilisateur
analogique A
Utilisateur
analogique B
Commutateur AutoView 2000
Voies ARI
Serveurs
primaires
Commutateur AutoView 2000 (monté en cascade)
Voie ACI
Serveurs
secondaires
Figure 2.3 : Configuration du commutateur AutoView 2000 avec un commutateur en cascade
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Guide d’installation et d’utilisation du commutateur AutoView 2000
Ajout de commutateurs classiques
Vous avez la possibilité de connecter des commutateurs classiques au commutateur AutoView 2000
en vue d’optimiser l’intégration de ce dernier à la configuration existante. Dans un système en
cascade, chaque voie ARI peut être utilisée par un maximum de 24 serveurs. Reportez-vous au
tableau suivant pour vérifier la compatibilité des commutateurs classiques avec le commutateur
AutoView 2000.
Tableau 2.1 : Compatibilité avec les commutateurs classiques
Commutateur classique
Commutateur OutLook ES
Commutateur AutoView
Modèles
140ES, 180ES, 280ES, 1160ES, 2160ES, 4160ES
AV200-4, AV200-8, AV400-4, AV400-8, AV416, AV424
Utilisateur analogique local A
Commutateur AutoView 2000
Module AVRIQ
Câbles série PS/2,
USB et Sun disponibles
Module AVRIQ
Commutateur AutoView 200/400
Commutateur OutLook ES
Serveur 1
Serveur 2
Figure 2.4 : Configuration du commutateur AutoView 2000 avec un commutateur KVM classique
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 2: Installation
11
Ajout d’un commutateur KVM classique
1. Montez le commutateur KVM sur votre étagère à rack. Munissez-vous d’un câble CAT 5 pour
relier votre commutateur AutoView 2000 et le module AVRIQ au commutateur.
2. Reliez les connecteurs du clavier, du moniteur et de la souris du module AVRIQ à une voie
utilisateur du commutateur en cascade.
3. Reliez une extrémité du câble CAT 5 au connecteur RJ-45 du module AVRIQ.
4. Reliez l’autre extrémité du câble CAT 5 à une voie disponible à l’arrière du commutateur
AutoView 2000.
5. Connectez les serveurs au commutateur monté en cascade conformément aux instructions
accompagnant le dispositif.
6. Mettez le commutateur monté en cascade hors tension puis à nouveau sous tension pour que la
voie de l’utilisateur local reconnaisse le module AVRIQ.
7. Répétez les étapes 2 à 5 pour tous les commutateurs montés en cascade que vous souhaitez
relier au système.
Connexion de périphériques locaux
1. Sélectionnez le clavier, le moniteur et la souris à connecter à l’utilisateur local A.
2. Localisez le groupe de voies marqué A à l’arrière de l’équipement. Connectez les
périphériques aux voies correspondantes.
3. Dans le cas du commutateur AutoView 2000 à 16 voies pour utilisateurs multiples, répétez les
étapes 1 et 2 pour le groupe de voies analogiques marqué B.
4. Rassemblez et étiquetez les câbles afin de faciliter leur identification.
Configuration du système de commutation AutoView 2000
Le système de commutation AutoView 2000 est capable de détecter et de configurer automatiquement
toutes les voies de l’équipement. Le chapitre 3 fournit des instructions détaillées sur la dénomination
et la personnalisation des voies ainsi que sur la configuration de l’interface OSCAR.
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Guide d’installation et d’utilisation du commutateur AutoView 2000
Download from Www.Somanuals.com. All Manuals Search And Download.
13
CHAPITRE
Opérations de base
3
Contrôle du système par les voies analogiques
Le commutateur AutoView 2000 est équipé de deux groupes de voies analogiques situés à l’arrière de
l’unité qui vous permettent de relier un moniteur ainsi qu’un clavier et une souris PS/2 pour un accès
analogique direct. Le commutateur AutoView 2000 fonctionne avec OSCAR, l’interface graphique
utilisateur intuitive qui vous permet de configurer votre système et de sélectionner les ordinateurs.
Visualisation et sélection des voies et des serveurs
Utilisez la boîte de dialogue Principal (Main) d’OSCAR pour visualiser, configurer et contrôler les
serveurs du système de commutation AutoView 2000. Vous pouvez afficher vos serveurs par nom,
par voie ou selon le numéro d’identification électronique (EID) unique intégré dans chaque module
AVRIQ. Lors du premier lancement de l’interface OSCAR, la liste des voies générée par l’interface
s’affiche par défaut.
La colonne Port (Voie) indique la voie ARI à laquelle un serveur est relié. Si vous reliez un
commutateur KVM classique au commutateur AutoView 2000 principal ou à un commutateur
AutoView 2000 monté en cascade, le premier numéro qui s’affiche correspond au numéro de la
voie ARI ; le second correspond à la voie du commutateur à laquelle le serveur est connecté. Par
exemple, sur la figure 3.1, les serveurs 04-03 et 01-02 sont connectés à des commutateurs.
Accès à la boîte de dialogue Main (Principal)
Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Main (Principal) s’affiche.
Figure 3.1 : Exemple de boîte de dialogue Main (Principal) configurée
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Guide d’installation et d’utilisation du commutateur AutoView 2000
NOTA : Vous pouvez également lancer l’interface OSCAR en appuyant deux fois de suite dans l’intervalle d’une
seconde sur la touche Ctrl. Vous pouvez utiliser cette combinaison à chaque fois que vous voyez Impr. écran
mentionné dans ce guide d’installation et d’utilisation.
Visualisation de l’état du commutateur
L’état des serveurs du système est indiqué dans les colonnes de droite de la boîte de dialogue Main
(Principal). Le tableau suivant présente les différents symboles d’état.
Tableau 3.1 : Symboles d’état utilisés dans l’interface OSCAR
Symbole
Description
Module AVRIQ en ligne (cercle vert).
Module AVRIQ hors ligne ou défectueux.
Serveur monté en cascade à partir d’un commutateur classique monté en cascade.
Commutateur en ligne et sous tension.
Serveur monté en cascade à partir d’un commutateur classique monté en cascade.
Commutateur hors ligne ou hors tension.
Module AVRIQ en cours de mise à jour (cercle jaune).
Accès au module AVRIQ par la voie utilisateur indiquée (caractère vert).
Module AVRIQ bloqué par la voie utilisateur indiquée (caractère noir).
Sélection des serveurs
Sélectionnez des serveurs à partir de la boîte de dialogue (Main) Principal. Lorsque vous
sélectionnez un serveur, le matériel reconfigure le clavier et la souris en fonction des paramètres
adaptés à ce serveur.
Sélection d’un serveur
Cliquez deux fois sur le nom, le numéro EID ou le numéro de voie du serveur.
- ou -
Si les serveurs sont affichés par voie (bouton Voie sélectionné), saisissez le numéro de voie et
appuyez sur Entrée.
- ou -
Si les serveurs sont affichés par nom ou par numéro EID (bouton Nom ou EID sélectionné),
saisissez les premiers caractères du nom du serveur ou du numéro EID pour l’identifier de manière
unique et appuyez sur la touche Entrée.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
15
Sélection du serveur précédent
Appuyez sur Impr écran, puis sur Retour arrière. Ce raccourci clavier permet d’alterner entre la
connexion actuelle et la connexion précédente.
Déconnexion de l’utilisateur d’un serveur
Appuyez sur Impr écran puis sur Alt+0. Ceci place l’utilisateur en état libre, sans aucun serveur
sélectionné. L’indicateur d’état du bureau affiche le message Libre.
Commutation logicielle
La commutation logicielle permet de changer de serveur à l’aide d’un raccourci clavier. Vous pouvez
passer à un serveur par commutation logicielle en appuyant sur Impr écran puis en saisissant les pre-
miers caractères de son nom ou de son numéro. Si vous avez configuré un retard d’affichage et que vous
exécutez le raccourci clavier avant que ce délai ne se soit écoulé, l’interface OSCAR ne s’affiche pas.
Configuration des serveurs en vue d’une commutation logicielle
1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Main
(Principal) s’affiche.
2. Cliquez sur Config. - Menu. La boîte de dialogue Menu s’affiche.
3. Dans le champ Retard d’affichage, indiquez la durée, en secondes, du retard d’affichage
souhaité entre le moment où vous appuyez sur Impr écran et l’affichage de la boîte de dialogue
Main (Principal).
4. Cliquez sur OK.
Sélection d’un serveur par commutation logicielle
1. Pour sélectionner un serveur, appuyez sur Impr écran. Si les serveurs sont affichés par voie
(bouton Voie sélectionné), saisissez le numéro de voie et appuyez sur Entrée.
- ou -
Si les serveurs sont affichés par nom ou par numéro EID (bouton Name [Nom] ou EID
sélectionné), saisissez les premiers caractères du nom du serveur ou du numéro EID pour
l’identifier de manière unique et appuyez sur la touche Entrée.
2. Pour revenir au serveur précédent, appuyez sur Impr écran, puis sur Retour arrière.
Navigation dans l’interface OSCAR
Le tableau suivant décrit comment utiliser le clavier et la souris pour naviguer dans l’interface OSCAR.
Tableau 3.2 : Concepts de base de la navigation dans OSCAR
Touche(s)
Impr écran
Action
Appuyez deux fois sur Impr écran pour envoyer la commande Impr écran à
l’équipement actuellement sélectionné.
F1
Affiche l’aide relative à la boîte de dialogue active.
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Guide d’installation et d’utilisation du commutateur AutoView 2000
Tableau 3.2 : Concepts de base de la navigation dans OSCAR (suite)
Touche(s)
Action
Ferme la boîte de dialogue active sans enregistrer les modifications et ouvre la
dernière boîte de dialogue affichée. Dans la boîte de dialogue Main (Principal) :
ferme OSCAR et affiche l’indicateur. Dans une boîte de message : ferme la fenêtre
contextuelle et affiche la boîte de dialogue active.
Echap
Alt+Hotkey (séquence Ouvre les boîtes de dialogue, sélectionne ou active les options et exécute les actions
de raccourci clavier)
en combinaison avec les lettres soulignées ou autres caractères désignés.
Alt+X
Ferme la boîte de dialogue active et revient à la boîte de dialogue précédente.
Alt+O
Sélectionne le bouton OK et active la boîte de dialogue précédemment affichée.
Dans une zone de texte : sélectionne le texte à modifier et active les flèches Gauche
et Droite du clavier permettant de déplacer le curseur. Appuyez de nouveau sur
Entrée pour quitter le mode d’édition.
Simple clic, Entrée
Termine l’opération de commutation dans la boîte de dialogue Main (Principal) et
quitte l’interface OSCAR.
Entrée
Impr écran,
Retour arrière
Permet de revenir à la sélection précédente.
Déconnecte immédiatement un utilisateur d’un serveur ; aucun serveur n’est
sélectionné. L’indicateur d’état affiche le message Free (Libre). (Ceci ne s’applique
qu’au caractère 0 du clavier, non du pavé numérique.)
Impr écran, Alt+0
Active immédiatement l’économiseur d’écran, bloquant ainsi l’accès à la console si
elle est protégée par un mot de passe.
Impr écran, Pause
Flèches Haut/Bas
Déplacent le curseur d’une ligne à l’autre dans les listes.
Flèches Droite/
Gauche
Déplacent le curseur d’une colonne à l’autre. Lors de la modification du contenu
d’une zone de texte : déplacent le curseur au sein de la colonne.
Page Précédente/
Suivante
Descend ou remonte d’une page dans les listes Name (Nom) et Port (Voie) et dans
les pages d’aide.
Origine/Fin
Suppr
Positionne le curseur au début ou à la fin d’une liste.
Supprime la sélection actuelle de la liste de balayage ou efface les caractères d’une
zone de texte.
Supprime les données de la ligne sélectionnée jusqu’à la fin de la liste lors de la
modification d’une liste de balayage.
Maj+Suppr
Page Précédente/
Suivante
Descend ou remonte d’une page dans les listes Name (Nom) et Port (Voie) et dans
les pages d’aide.
Chiffres
Saisissez-les depuis le clavier ou le pavé numérique.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
17
Fonctions de configuration de l’interface OSCAR
Vous pouvez configurer votre commutateur AutoView 2000 à partir de la boîte de dialogue Setup
(Configuration) de l’interface OSCAR. Cliquez sur le bouton Names (noms) lors de la configuration
initiale du matériel afin d’identifier les serveurs par des noms uniques. Les autres fonctions de la
boîte de dialogue Setup (Configuration) permettant de gérer les tâches de routine de vos serveurs
depuis l’interface OSCAR.
Tableau 3.3 : Fonctions de configuration pour gérer les tâches de routine des serveurs
Fonction
Action
Passer d’un mode de tri numérique des serveurs (par numéro de voie ou EID) à un mode
de tri alphabétique (par nom). Modifier le retard d’affichage, délai entre le moment où
Impr écran est sélectionné et l’affichage de l’interface OSCAR.
Menu
Flag (Indicateur)
Modifier l’affichage, la temporisation, la couleur et la position de l’indicateur d’état.
Configurer un contrôle simultané de plusieurs serveurs à l’aide du clavier et de la souris.
Configurer une méthode de balayage personnalisée pouvant s’appliquer à 16 serveurs.
Broadcast
(Diffusion)
Scan (Balayage)
Security
(Sécurité)
Sélectionner des mots de passe pour restreindre l’accès aux serveurs. Activer
l’économiseur d’écran.
Devices
(Équipements)
Identifier le nombre de voies correspondant pour chaque commutateur relié en cascade.
Identifier les serveurs à l’aide de noms uniques.
Names (Noms)
Switch
(Commutation)
Sélectionner le mode de commutation et le délai d’expiration du mode partagé.
Accès à la boîte de dialogue Setup (Configuration)
1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Main
(Principal) s’affiche.
2. Cliquez sur Setup (Configuration). La boîte de dialogue Setup (Configuration) s’affiche.
Figure 3.2 : Boîte de dialogue Setup (Configuration)
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Guide d’installation et d’utilisation du commutateur AutoView 2000
Attribution de noms aux serveurs
Utilisez la boîte de dialogue Names (Noms) pour identifier chaque serveur par nom plutôt que par
numéro de voie. La liste Names (Noms) est toujours triée par numéro de voie. Les noms sont
enregistrés dans le moduleAVRIQ donc, même si vous déplacez le câble ou le serveur vers une
autre voie ARI, le nom et la configuration sont reconnus par le commutateur.
NOTA : Si un serveur est mis hors tension, son module AVRIQ correspondant n’apparaîtra pas dans la liste
Names (Noms).
Accès à la boîte de dialogue Names (Noms)
1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Main
(Principal) s’affiche.
2. Cliquez sur Setup (Config.) - Names (Noms). La boîte de dialogue Names (Noms) s’affiche.
Figure 3.3 : Boîte de dialogue Names (Noms)
NOTA : Si la liste de serveurs est modifiée, le curseur de la souris se transforme en sablier pendant que la liste
est automatiquement mise à jour. Aucune opération souris ou clavier n’est acceptée tant que la mise à jour de la
liste n’est pas terminée.
Attribution d’un nom au serveur
1. Dans la boîte de dialogue Names (Noms), sélectionnez un nom de serveur ou un numéro de voie
et cliquez sur Modify (Modif.). La boîte de dialogue Name Modify (Modifier nom) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
19
Figure 3.4 : Boîte de dialogue Name Modify (Modifier nom)
2. Saisissez un nom dans le champ New Name (Nouveau nom). Les noms attribués aux serveurs
peuvent contenir jusqu’à 15 caractères. Les caractères autorisés sont : A à Z, a à z, 0 à 9,
l’espace et le tiret.
3. Cliquez sur OK pour transférer le nouveau nom vers la boîte de dialogue Names (Noms). Votre
sélection n’est pas sauvegardée tant que vous n’avez pas cliqué sur OK dans la boîte de
dialogue Names (Noms).
4. Répétez les étapes 1 à 3 pour chacun des serveurs du système.
5. Cliquez sur OK dans la boîte de dialogue Names (Noms) pour enregistrer vos modifications.
- ou -
Cliquez sur X ou appuyez sur Echap pour quitter la boîte de dialogue sans enregistrer les
modifications.
NOTA : Si aucun nom n’a été attribué à un module AVRIQ, le numéro EID est utilisé comme nom par défaut.
Assignation des types d’équipement :
Le commutateur AutoView 2000 détecte automatiquement les commutateurs KVM en cascade,
vous devez cependant préciser le nombre de voies du commutateur en cascade à l’aide de la boîte
de dialogue Devices (Équipements). Sw-8 ou Sw-24 s’affiche dans la catégorie Type pour le
commutateur en cascade. Lorsque vous sélectionnez ce commutateur dans la liste, le bouton
Modify (Modif.) apparaît, ce qui vous permet de lui assigner le nombre de voies approprié.
NOTA : Le bouton Modify (Modif.) ne s’affiche que si un commutateur qui peut être configuré est sélectionné.
Accès à la boîte de dialogue Devices (Équipements)
1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Main (Principal)
s’affiche.
2. Cliquez sur Setup (Config.) - Devices (Équipement). La boîte de dialogue Devices
(Équipements) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Guide d’installation et d’utilisation du commutateur AutoView 2000
Figure 3.5 : Boîte de dialogue Devices (Équipements)
Lorsque le commutateur AutoView détecte un commutateur en cascade, vous remarquez que la
numérotation des voies est modifiée pour prendre en compte chaque serveur de ce commutateur.
Par exemple, si le commutateur est relié à la voie ARI 6, la voie du commutateur est numérotée 06
et chaque serveur relié à ce commutateur est numéroté dans l’ordre 06-01, 06-02 et ainsi de suite.
Assignation d’un type d’équipement :
1. Dans la boîte de dialogue Devices (Équipements), sélectionnez le nombre de voies approprié.
2. Cliquez sur Modify (Modif.). La boîte de dialogue Device Modify (Modif. Equip.) s’affiche.
Figure 3.6 : Boîte de dialogue Device Modify (Modif. équip.)
3. Choisissez le nombre de voies prises en charge par votre commutateur monté en cascade et
cliquez sur OK.
4. Répétez les étapes 1 à 3 pour chaque voie pour laquelle un type de dispositif doit être assigné.
5. Dans la boîte de dialogue Devices (Équipements), cliquez sur OK pour enregistrer les
paramètres.
NOTA : Vous devez cliquer sur OK dans la boîte de dialogue Device Modify (Modif. équip.) pour enregistrer les
modifications effectuées dans la boîte de dialogue Device Modify (Modif. équip.)
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
21
Modification de l’affichage
Utilisez la boîte de dialogue Menu pour modifier l’ordre d’affichage des serveurs et configurer un
retard d’affichage de l’interface OSCAR. La configuration de l’ordre de visualisation affecte
l’affichage des serveurs sur plusieurs écrans, notamment les boîtes de dialogue Main (Principal),
Devices (Équipements) et Broadcast (Diffusion).
Accès à la boîte de dialogue Menu
1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Main
(Principal) s’affiche.
2. Dans la boîte de dialogue Main (Principal), cliquez sur Setup (Config) - Menu. La boîte de
dialogue Menu s’affiche.
Figure 3.7 : Boîte de dialogue Menu
Choix de l’ordre d’affichage par défaut des serveurs
1. Sélectionnez Name (Nom) pour afficher les serveurs dans l’ordre alphabétique (par nom).
- ou -
Sélectionnez EID pour afficher les serveurs dans l’ordre numérique (par numéro EID).
- ou -
Sélectionnez Port (Voie) pour afficher les serveurs dans l’ordre numérique (par numéro de voie.
2. Cliquez sur OK.
Définition du retard d’affichage de l’interface OSCAR
1. Saisissez la durée en secondes (de 0 à 9) du retard d’affichage souhaité entre le moment où
vous appuyez sur Impr écran et l’affichage d’OSCAR. La valeur 0 lance immédiatement
l’interface OSCAR, sans aucun délai.
2. Cliquez sur OK.
La définition d’un retard d’affichage permet d’exécuter une commutation au clavier sans afficher
l’interface OSCAR. Pour exécuter une commutation au clavier, reportez-vous à la section
Commutation logicielle dans ce chapitre.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
Guide d’installation et d’utilisation du commutateur AutoView 2000
Contrôle de l’indicateur d’état
L’indicateur d’état s’affiche sur le bureau et indique le nom ou le numéro EID du serveur sélec-
tionné ou l’état de la voie sélectionnée. La boîte de dialogue Flag (Indicateur) permet de configurer
l’indicateur de manière qu’il affiche le nom ou le numéro EID du serveur ; elle permet également de
modifier la couleur, l’opacité, le temps d’affichage et l’emplacement sur le bureau de l’indicateur.
Tableau 3.4 : Indicateurs d’état de l’interface OSCAR
Flag (Indicateur)
Description
Type d’indicateur par nom
Type d’indicateur par numéro EID
Indicateur signalant que l’utilisateur a été déconnecté de tous les systèmes
Indicateur indiquant que le mode Broadcast (Diffusion) est activé
Accès à la boîte de dialogue Flag (Indicateur)
1. Appuyez sur Impr écran. La boîte de dialogue Main (Principal) s’affiche.
2. Cliquez sur Setup (Config.) - Flag (Indicateur). La boîte de dialogue Flag (Indicateur) s’affiche.
Figure 3.8 : Boîte de dialogue Flag (Indicateur)
Définition du mode d’affichage de l’indicateur d’état
1. Sélectionnez Name (Nom) ou EID pour déterminer quelle information sera affichée.
2. Sélectionnez Displayed (Affiché) pour que l’indicateur soit toujours affiché ou Timed
(Temporisé) pour que l’affichage ne dure que cinq secondes après une commutation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
23
3. Sélectionnez une couleur dans la zone Display Color (Couleur d’affichage).
4. Dans la zone Display Mode (Mode d’affichage), sélectionnez Opaque pour une couleur pleine
ou Transparent pour que le bureau soit visible en transparence.
5. Positionnement de l’indicateur d’état sur le bureau
a. Cliquez sur Set Position (Fixer position) pour afficher l’écran Position Flag
(Fixer position).
b. Cliquez sur la barre de titre avec le bouton gauche de la souris et faites glisser la boîte vers
l’emplacement souhaité.
c. Cliquez avec le bouton droit de la souris pour revenir à la boîte de dialogue Flag
(Indicateur).
Figure 3.9 : Set Position (Fixer position)
NOTA : Vous devez cliquer sur OK dans la boîte de dialogue Flag (Indicateur) pour enregistrer le nouvel
emplacement de l’indicateur.
6. Cliquez sur OK pour enregistrer les paramètres.
- ou -
Cliquez sur X pour quitter sans enregistrer les modifications.
Paramétrage de sécurité de la console
L’interface OSCAR vous permet de configurer les paramètres de sécurité de votre console à la voie
analogique. Vous pouvez définir un mode d’économiseur d’écran qui s’exécute automatiquement
lorsque la console reste inutilisée pendant un temps d’inactivité déterminé. Une fois l’économiseur
d’écran activé, la console est bloquée tant que vous n’appuyez pas sur une touche du clavier ou que
vous ne déplacez pas la souris. Vous devez alors saisir votre mot de passe pour continuer.
Utilisez la boîte de dialogue Security (Sécurité) pour verrouiller votre console en la protégeant par
un mot de passe, pour choisir ou modifier votre mot de passe et pour activer l’économiseur d’écran.
NOTA : Si un mot de passe a été défini au préalable, vous devez le saisir pour pouvoir accéder à la boîte de
dialogue Security (Sécurité).
Accès à la boîte de dialogue Security (Sécurité)
1. Appuyez sur Impr écran pour lancer l’interface OSCAR. La boîte de dialogue Main
(Principal) s’affiche.
2. Cliquez sur Setup (Config.) - Security (Sécurité). La boîte de dialogue Security (Sécurité)
s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
24
Guide d’installation et d’utilisation du commutateur AutoView 2000
Figure 3.10 : Boîte de dialogue Security (Sécurité)
Définition ou modification du mot de passe
1. Cliquez une fois et appuyez sur Entrée ou cliquez deux fois dans la zone de texte New (Nouveau).
2. Saisissez le nouveau mot de passe dans la zone de texte New (Nouveau) et appuyez sur Entrée. Les
mots de passe doivent être composés à la fois de lettres et de chiffres. Ils sont sensibles à la casse
et peuvent contenir jusqu’à 12 caractères parmi les suivants : A à Z, a à z, 0 à 9, l’espace et le tiret.
3. Dans la zone Repeat (Confirmation), ressaisissez le mot de passe et appuyez sur Entrée.
4. Cliquez sur OK si vous souhaitez uniquement modifier le mot de passe puis fermer la boîte de
dialogue.
NOTA : En cas de perte ou d’oubli du mot de passe, le commutateur doit être retourné au fabricant pour
réparation. Veuillez contacter le service d’assistance d’Avocent. Reportez-vous à l’Annexe C : Assistance
technique pour obtenir les coordonnées.
Protection de la console par un mot de passe
1. Définissez le mot de passe en suivant la procédure décrite précédemment.
2. Sélectionnez Enable Screen Saver (Activer l’écon. d’écran).
3. Spécifiez en minutes le temps d’inactivité (de 1 à 99) avant l’activation de la protection par
mot de passe et le démarrage de l’économiseur d’écran.
4. Dans la zone Mode, sélectionnez Energy (Énergie) si votre écran affiche le symbole
ENERGY STAR® ; sinon, sélectionnez Screen (écran).
ATTENTION : L’activation du mode Énergie alors que l’écran n’est pas compatible avec la norme ENERGY STAR®
peut l’endommager.
5. (Facultatif) Cliquez sur Test pour lancer le test de l’économiseur d’écran ; celui-ci dure
10 secondes, puis la boîte de dialogue Security (Sécurité) réapparaît.
6. Cliquez sur OK.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
25
Connexion à la console
1. Appuyez sur n’importe quelle touche du clavier ou déplacez la souris.
2. La boîte de dialogue Password (Mot de passe) s’affiche. Saisissez votre mot de passe puis
cliquez sur OK.
3. La boîte de dialogue Main (Principal) s’affiche si le mot de passe saisi est correct.
Suppression de la protection par mot de passe de la console
1. Depuis la boîte de dialogue Main (Principal), cliquez sur Setup (Config.) - Security (Sécurité) ;
la boîte de dialogue Password (Mot de passe) s’affiche. Saisissez votre mot de passe puis
cliquez sur OK.
2. Dans la boîte de dialogue Security (Sécurité), cliquez une fois et appuyez sur Entrée ou cliquez
deux fois dans la zone New (Nouveau). Ne renseignez pas la zone. Appuyez sur Entrée.
3. Cliquez une fois dans la zone de texte Repeat (Confirmation) et appuyez sur Entrée ou cliquez
deux fois dans la zone Repeat (Confirmation). Ne renseignez pas la zone. Appuyez sur Entrée.
4. Cliquez sur OK si vous souhaitez supprimer votre mot de passe.
Activation du mode d’économiseur d’écran sans protection par mot de passe
1. Si votre console ne nécessite pas l’utilisation d’un mot de passe pour accéder à la boîte de
dialogue Security (Sécurité), passez à l’étape 2.
- ou -
Si votre console est protégée par un mot de passe, voyez la procédure précédente, puis passez à
l’étape 2.
2. Sélectionnez Enable Screen Saver (Activer l’écon. d’écran).
3. Spécifiez en minutes la durée du temps d’inactivité (de 1 à 99) avant activation de
l’économiseur d’écran.
®
4. Sélectionnez Energy (Énergie) si votre écran affiche le symbole ENERGY STAR , sinon
sélectionnez Screen (Écran).
ATTENTION : Vous risquez d’endommager l’écran si vous activez le mode Energy (Énergie) alors que l’écran
n’est pas compatible avec la norme ENERGY STAR®.
5. (Facultatif) Cliquez sur Test pour lancer le test de l’économiseur d’écran ; celui-ci dure
10 secondes, puis la boîte de dialogue Security (Sécurité) réapparaît.
6. Cliquez sur OK.
NOTA : L’activation du mode d’économiseur d’écran déconnecte automatiquement l’utilisateur d’un serveur ;
aucun serveur n’est activé. L’indicateur d’état affiche Free (Libre).
Annulation du mode d’économiseur d’écran
Appuyez sur n’importe quelle touche du clavier ou déplacez la souris. La boîte de dialogue Main
(Principal) s’affiche et toute connexion précédente au serveur est rétablie.
Download from Www.Somanuals.com. All Manuals Search And Download.
26
Guide d’installation et d’utilisation du commutateur AutoView 2000
Désactivation de l’économiseur d’écran
1. Dans la boîte de dialogue Security (Sécurité), désactivez la case Enable Screen Saver
(Activer l’écon. d’écran).
2. Cliquez sur OK.
Activation immédiate de l’économiseur d’écran
Appuyez sur Impr écran, puis sur Pause.
Affichage des informations relatives à la version
L’interface OSCAR permet d’afficher les informations relatives aux versions du commutateur
AutoView 2000 et du firmware du module AVRIQ. Pour optimiser les performances, pensez à
mettre à jour régulièrement votre firmware. Pour plus d’informations, consultez l’Annexe A.
Visualisation des informations relatives à la version :
1. Appuyez sur Impr écran. La boîte de dialogue Main (Principal) s’affiche.
2. Cliquez sur Commands (Commandes) - Display Versions (Affichage versions). La boîte de
dialogue Version s’affiche. La moitié supérieure de la boîte de dialogue donne les versions des
sous-systèmes du commutateur.
Figure 3.11 : Boîte de dialogue Version
3. Cliquez sur AVRIQ pour visualiser les informations de version relatives aux différents
modules. La boîte de dialogue AVRIQ Selection (Sélection AVRIQ) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
27
Figure 3.12 : Boîte de dialogue AVRIQ Selection (Sélection AVRIQ)
4. Sélectionnez le module AVRIQ que vous souhaitez visualiser et cliquez sur le bouton Version.
La boîte de dialogue AVRIQ Version (Version AVRIQ) s’affiche. Pour plus d’informations sur
le chargement du firmware, consultez l’Annexe A.
Figure 3.13 : Boîte de dialogue AVRIQ Version (Version AVRIQ)
5. Cliquez sur la case de fermeture X pour fermer la boîte de dialogue AVRIQ Version
(Version AVRIQ).
Balayage du système
En mode balayage, le matériel analyse automatiquement les voies une par une (serveur par serveur).
Vous pouvez balayer jusqu’à 16 serveurs en choisissant ceux que vous souhaitez balayer et en
précisant le nombre de secondes durant lesquelles chaque serveur s’affiche. L’ordre de balayage est
déterminé par la position des serveurs dans la liste. La liste est toujours affichée dans cet ordre. Vous
pouvez cependant choisir d’afficher les serveurs par nom ou par numéro EID en appuyant sur le
bouton correspondant.
Download from Www.Somanuals.com. All Manuals Search And Download.
28
Guide d’installation et d’utilisation du commutateur AutoView 2000
Ajout de serveurs à la liste de balayage
1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran. La boîte de dialogue Main
(Principal) s’affiche.
2. Cliquez sur Setup - Scan (Config. - Balayage). La boîte de dialogue Scan (Balayage) s’affiche.
Figure 3.14 : Boîte de dialogue Scan (Balayage)
3. Cette boîte de dialogue dresse la liste de tous les serveurs reliés à votre matériel. Cochez les
cases associées aux serveurs que vous souhaitez balayer.
- ou -
Cliquez deux fois sur le nom ou sur le numéro de voie du serveur.
- ou -
Apppuyez sur Alt + le numéro du serveur à balayer. Vous pouvez sélectionner jusqu’à
16 serveurs de la liste.
4. Dans le champ Scan Time (Durée balayage), indiquez la durée, en secondes (de 3 à 99), du
délai de réponse souhaité avant que le balayage ne passe au serveur suivant de la séquence.
5. Cliquez sur OK.
Suppression d’un serveur de la liste de balayage
1. Dans la boîte de dialogue Scan (Balayage), désélectionnez les cases à cocher correspondant
aux serveurs à supprimer.
- ou -
Cliquez deux fois sur le nom ou sur le numéro de voie du serveur.
- ou -
Cliquez sur le bouton Clear (Effacer) pour supprimer tous les serveurs de la liste de balayage.
2. Cliquez sur OK.
Lancement du mode de balayage
1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran. La boîte de dialogue Main
(Principal) s’affiche.
2. Cliquez sur Commands (Commandes). La boîte de dialogue Commands (Commandes) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
29
Figure 3.15 : Boîte de dialogue Commands (Commandes)
3. Sélectionnez Scan Enable (Activer le balayage) dans la boîte de dialogue Commands
(Commandes).
4. Cliquez sur la case de fermeture X pour fermer la boîte de dialogue Commands (Commandes).
NOTA : Le balayage commence lorsque l’indicateur ou la boîte de dialogue Main (Principal) s’affiche. Le
balayage est bloqué dans toute autre boîte de dialogue OSCAR.
Interruption du mode de balayage
1. Sélectionnez un serveur si l’interface OSCAR est ouverte.
- ou -
Déplacez la souris ou appuyez sur une touche quelconque du clavier si l’interface OSCAR
n’est pas ouverte. Le balayage s’interrompt au niveau du serveur sélectionné.
- ou -
Appuyez sur Impr écran. La boîte de dialogue Main (Principal) s’affiche.
2. Cliquez sur Commands (Commandes). La boîte de dialogue Commands (Commandes) s’affiche.
3. Désactivez la fonction Scan Enable (Activer le balayage).
Diagnostic du système
Vous pouvez valider l’intégrité de votre système à l’aide de la commande Run Diagnostics (Lancer
le diagnostic). Cette commande permet de vérifier les sous-systèmes fonctionnels de la carte mère
(mémoire, communications, commande du commutateur et voies vidéo) pour chaque contrôleur du
système. Lorsque vous sélectionnez la commande Run Diagnostics (Lancer le diagnostic), un
message d’avertissement s’affiche pour vous indiquer que tous les utilisateurs (distants et locaux)
vont être déconnectés. Cliquez sur OK pour confirmer et commencer le test.
La boîte de dialogue Diagnostics s’affiche. La section supérieure de la boîte de dialogue présente
les tests effectués au niveau du matériel tandis que la partie inférieure divise les modules AVRIQ
testés en trois catégories : en ligne, hors ligne et suspect.
NOTA : Un module AVRIQ peut sembler hors ligne alors qu’il est en train d’être mis à jour.
Download from Www.Somanuals.com. All Manuals Search And Download.
30
Guide d’installation et d’utilisation du commutateur AutoView 2000
Figure 3.16 : Boîte de dialogue Diagnostics
À la fin du test, chaque élément testé est précédé d’un symbole de réussite (cercle vert) ou d’un
symbole d’échec (croix rouge). Le tableau ci-dessous décrit chacun des tests réalisés.
Tableau 3.5 : Détails des tests de diagnostic
Test
Description
Tests de mémoire
Indique l’état de la RAM de la carte mère
Indique l’état de la RAM de la carte mère
Firmware des CRC
Interfaces de com
Valide les images du firmware utilisé qui sont enregistrées dans la mémoire
FLASH du système
Vérifie que le contrôleur de la matrice du commutateur est accessible et
fonctionnel
Ctrlr commutateur
Indique l’état du moniteur connecté à la voie locale
Voie vidéo locale
Indique le nombre total de modules AVRIQ connectés et sous tension
Modules AVRIQ en ligne
Indique le nombre de modules AVRIQ qui ont été connectés avec succès
antérieurement et qui sont hors tension
Modules AVRIQ hors ligne
Indique le nombre de modules AVRIQ qui ont été détectés, mais qui ne sont pas
Modules AVRIQ suspects disponibles pour la connexion ou qui ont rejeté des paquets de données lors des
tests du PING
Lancement des tests de diagnostic
1. Si l’interface OSCAR n’est pas lancée, appuyez sur Impr écran. La boîte de dialogue Main
(Principal) s’affiche.
2. Cliquez sur Commands (Commandes) - Run Diagnostics (Lancer le diagnostic). Un
avertissement s’affiche pour vous signaler que tous les utilisateurs vont être déconnectés.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
31
Figure 3.17 : Boîte de dialogue Diagnostics Warning (Avertissement diagnostics)
3. Cliquez sur OK pour lancer le diagnostic.
- ou -
Cliquez sur X ou appuyez sur Echap pour quitter la boîte de dialogue sans réaliser de test de
diagnostic.
4. Tous les utilisateurs sont déconnectés et la boîte de dialogue Diagnostics s’affiche.
5. À la fin de chaque test, un symbole de réussite (cercle vert) ou d’échec (croix rouge) s’affiche.
Les tests sont terminés lorsque le symbole du dernier test est visible à l’écran.
Diffusion vers les serveurs
L’utilisateur analogique peut contrôler simultanément plus d’un serveur dans un système, ce qui
garantit que tous les serveurs sélectionnés reçoivent les mêmes informations. Vous pouvez choisir
de diffuser les frappes au clavier ou les mouvements de la souris indépendamment les uns des autres.
NOTA : Vous pouvez diffuser simultanément vers 16 serveurs maximum, à raison d’un serveur par voie ARI.
Accès à la boîte de dialogue Broadcast (Diffusion)
1. Appuyez sur Impr écran. La boîte de dialogue Main (Principal) s’affiche.
2. Cliquez sur Setup (Config.) - Broadcast (Diffusion). La boîte de dialogue Broadcast
(Diffusion) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
32
Guide d’installation et d’utilisation du commutateur AutoView 2000
Figure 3.18 : Boîte de dialogue Broadcast (Diffusion)
NOTA : Diffusion des frappes au clavier - pour que les serveurs destinataires interprètent les combinaisons de
touches de manière identique, l’état du clavier doit être le même pour tous les serveurs. Tout particulièrement,
les modes Verr Num et Verr Maj doivent être paramétrés de la même manière sur tous les claviers. Lorsque le
matériel envoie les combinaisons de touches simultanément aux différents serveurs sélectionnés, certains
serveurs peuvent bloquer et donc retarder la transmission.
NOTA : Diffusion des mouvements de la souris - pour que la souris fonctionne correctement, les pilotes de
souris, les bureaux (le positionnement des icônes, par exemple) et les résolutions vidéo doivent être identiques
sur tous les systèmes. La souris doit également être placée au même endroit sur tous les écrans. Ces impératifs
étant difficiles à appliquer, la diffusion des mouvements de la souris vers plusieurs systèmes a parfois des
résultats imprévus.
Diffusion vers les serveurs sélectionnés
1. Dans la boîte de dialogue Broadcast (Diffusion), cochez les cases de la souris ou du clavier des
serveurs qui doivent recevoir les commandes de diffusion.
- ou -
Appuyez sur les flèches Haut ou Bas pour déplacer le curseur vers le serveur destinataire.
Appuyez ensuite sur les touches Alt+K pour sélectionner la case à cocher du clavier et/ou
Alt+M pour sélectionner celle de la souris. Recommencez la procédure pour chaque serveur
supplémentaire.
2. Cliquez sur OK pour enregistrer les paramètres et revenir à la boîte de dialogue Setup
(Configuration). Cliquez sur X ou appuyez sur Echap pour revenir à la boîte de dialogue Main
(Principal).
3. Cliquez sur Commands (Commandes). La boîte de dialogue Commands (Commandes) s’affiche.
4. Cochez la case Broadcast Enable (Activer la diffusion) pour activer la diffusion. La boîte de
dialogue Broadcast Enable Confirm/Deny (Activer/Désactiver la diffusion) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapitre 3: Opérations de base
33
Figure 3.19 : Boîte de dialogue Broadcast Enable Confirm/Deny (Activer/Désactiver la diffusion)
5. Cliquez sur OK pour activer la diffusion. Cliquez sur X ou appuyez sur Echap pour retourner à
la boîte de dialogue Commands (Commandes).
6. Si la diffusion est activée, saisissez les données ou effectuez les mouvements de souris à
diffuser à partir de la console utilisateur. Seuls les serveurs de la liste sont accessibles.
NOTA : Le deuxième utilisateur n’a pas accès aux serveurs lors de la diffusion.
Désactivation de la diffusion
À partir de la boîte de dialogue Commands (Commandes), décochez la case Broadcast Enable
(Activer la diffusion).
Modification du mode de commutation
Le commutateur AutoView 2000 permet de vous connecter aux serveurs reliés de deux manières
différentes : en mode Preemptive (Préemption) ou Cooperative (Coopération).
Sélectionnez le mode Preemptive (Préemption) (mode par défaut) pour autoriser la sélection à tout
moment de n’importe quel serveur par un utilisateur quelconque ; si un autre utilisateur exécute une
procédure de connexion, l’utilisateur en cours est déconnecté sans avertissement.
- ou -
Sélectionnez le mode Cooperative (Coopération) afin de maintenir la connexion utilisateur actuelle ;
l’utilisateur actuel ne sera ainsi pas déconnecté si un autre utilisateur demande une connexion.
Accès à la boîte de dialogue Switch (Commutateur)
1. Appuyez sur Impr écran. La boîte de dialogue Main (Principal) s’affiche.
2. Cliquez sur Setup-Switch (Config. - Commutateur). La boîte de dialogue Switch
(Commutateur) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
34
Guide d’installation et d’utilisation du commutateur AutoView 2000
Figure 3.20 : Boîte de dialogue Switch (Commutateur)
3. Sélectionnez au choix le mode Preemptive (Préemption) ou le mode Cooperative
(Coopération) comme mode de commutation.
Download from Www.Somanuals.com. All Manuals Search And Download.
35
ANNEXES
Annexes
Annexe A : Mises à jour FLASH
Mise à jour du commutateur AutoView 2000
Avocent fournit un utilitaire spécifique vous permettant de mettre à jour le firmware du
commutateur AutoView 2000. Cet utilitaire configure automatiquement les paramètres de
communication du port pour permettre un téléchargement direct depuis le serveur connecté.
Éléments indispensables à la mise à jour
•
Un serveur sous système d’exploitation Windows NT®, Windows ® 95, Windows 98 ou
Windows 2000
•
•
•
Une voie série (voie COM) libre sur le serveur
Un câble série null modem (DB mâle) reliant le commutateur au serveur
Une mise à jour du firmware
Mise à jour du firmware
1. Reliez le câble série standard à la voie COM du serveur et au connecteur série situé sur le
panneau arrière du commutateur. Notez la voie COM sélectionnée et mettez le commutateur
sous tension.
1. Connectez-vous au site http://www.avocent.com/support et cliquez sur product upgrades
(Mise à jour produits) pour accéder au fichier de mise à jour. Une fois le téléchargement
terminé, recherchez le fichier sur votre disque et décompressez-le.
2. Cliquez deux fois pour exécuter le fichier WUpDateAVO.exe.
3. Dans la boîte de dialogue qui s’affiche, sélectionnez la langue de préférence et la voie COM.
4. Cliquez sur Load (Charger).
5. Une fois le firmware mis à jour, le message suivant s’affiche Download complete
(Téléchargement terminé). Cliquez sur Done (Terminé) pour fermer la boîte de dialogue.
6. Une fois la mise à jour terminée, le commutateur redémarre automatiquement.
Cas d’erreurs possibles
Si le téléchargement ne s’effectue pas correctement, vérifiez les points suivants.
•
•
Vérifiez que la bonne voie COM est utilisée.
Vérifiez qu’aucun autre programme n’utilise la voie COM ou qu’aucune session DOS
window/shell ayant utilisé la voie COM n’est restée ouverte.
•
•
Vérifiez qu’une seconde exécution du programme WUpDate n’est pas en cours.
Vérifiez que le câble utilisé est un câble série null modem.
Download from Www.Somanuals.com. All Manuals Search And Download.
36
Guide d’installation et d’utilisation du commutateur AutoView 2000
•
Vérifiez dans les paramètres avancés de la voie COM que les mémoires tampon FIFO sont
sélectionnées et que la mémoire tampon est définie sur Haute.
ATTENTION : N’utilisez pas l’ordinateur pendant la mise à jour, pas même pour basculer d’une fenêtre à une
autre. Si nécessaire, fermez toutes les fenêtres autres que celle de la mise à jour. Si la mise à jour échoue
(suite à une panne de courant, par exemple), renouvelez l’opération.
Mise à jour du firmware du module AVRIQ
Il est possible de mettre à jour les modules AVRIQ individuellement ou collectivement.
Mise à jour simultanée de plusieurs modules AVRIQ
1. Appuyez sur Impr écran. La boîte de dialogue Main (Principal) s’affiche.
7. Cliquez sur Commands - AVRIQ Status (Commandes - État de l’AVRIQ). La boîte de dialogue
AVRIQ Status (État de l’AVRIQ) s’affiche.
Figure A.1 : Boîte de dialogue AVRIQ Status (État de l’AVRIQ)
8. Cliquez sur un ou plusieurs type(s) de module(s) à mettre à jour. Cliquez sur Upgrade
(Mise à jour).
9. La boîte de dialogue AVRIQ Upgrade (Mise à jour de l’AVRIQ) s’affiche. Cliquez sur OK
pour lancer la mise à jour et retourner à la boîte de dialogue AVRIQ Status (État de l’AVRIQ).
Download from Www.Somanuals.com. All Manuals Search And Download.
Annexes
37
Figure A.2 : Boîte de dialogue AVRIQ Upgrade (Mise à jour de l’AVRIQ)
Mise à jour du firmware d’un module AVRIQ particulier
1. Appuyez sur Impr écran. La boîte de dialogue Main (Principal) s’affiche.
2. Cliquez sur Commands (Commandes) - Display Versions (Affichage versions). La boîte de
dialogue Version s’affiche.
Figure A.3 : Boîte de dialogue Version
3. Cliquez sur AVRIQ pour visualiser les informations de version relatives aux différents
modules. La boîte de dialogue AVRIQ Selection (Sélection AVRIQ) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
38
Guide d’installation et d’utilisation du commutateur AutoView 2000
Figure A.4 : Boîte de dialogue AVRIQ Selection (Sélection AVRIQ)
4. Sélectionnez le module AVRIQ que vous souhaitez mettre à jour et cliquez sur le bouton
Version. La boîte de dialogue AVRIQ Version (Version AVRIQ) s’affiche.
Figure A.5 : Boîte de dialogue AVRIQ Version (Version AVRIQ)
5. Cliquez sur le bouton Load Firmware (Chrg Firmware). La boîte de dialogue AVRIQ Load
(Chargement AVRIQ) s’affiche.
Download from Www.Somanuals.com. All Manuals Search And Download.
Annexes
39
Figure A.6 : Boîte de dialogue AVRIQ Load (Chargement AVRIQ)
6. Cliquez sur OK pour lancer la mise à jour et retourner à la boîte de dialogue Status (État).
NOTA : Au cours d’une mise à jour, l’indicateur d’état de l’AVRIQ apparaît en jaune dans la boîte de dialogue
Main (Principal). Le module AVRIQ n’est pas disponible lorsqu’une mise à jour est en cours. Lorsqu’une mise à
jour est lancée, toute connexion active au serveur via le module AVRIQ est interrompue.
Download from Www.Somanuals.com. All Manuals Search And Download.
40
Guide d’installation et d’utilisation du commutateur AutoView 2000
Annexe B : Spécifications techniques
Tableau B.1 : Spécifications Produit
Spécifications produit du commutateur AutoView 2000
Voies serveur
Nombre
16
Types
Modules PS/2, Sun, USB et AVRIQ série
Connecteurs
Types de synchronisation
Plug and Play
Résolution vidéo
Mise à jour de la voie
Nombre
RJ-45
Horizontale et verticale séparées
DDC2B
Maximum pour la voie analogique 1 600 x 1 280 à 75 Hz
2
Type
RS-232 série
Mâle DB9
Connecteur
Groupes de voies analogiques
Nombre
2
Type
PS/2, VGA et ACI
Connecteurs
Dimensions
PS/2 miniDIN, D 15 broches, RJ-45
Dimensions
H x L x l
4,45 x 43,18 x 27,94 cm, facteur de forme 1U
Poids
3,6 kg sans les câbles
97 kJ/h
Dissipation calorifique
Débit d’air
3,8 l/s
Consommation d’énergie
12,5 W
Puissance d’alimentation (c.a.) 40 W au maximum
Download from Www.Somanuals.com. All Manuals Search And Download.
Annexes
41
Tableau B.1 : Spécifications Produit (suite)
Spécifications produit du commutateur AutoView 2000
Tension nominale
100 à 240 VC.A. auto-détecteur
d’alimentation (c.a.)
Courant nominal
0,5 A
d’alimentation (c.a.)
Câble d’alimentation (c.a.)
Câble trois fils 18 AWG avec fiche à trois conducteurs IEC-320 à
l’alimentation et une prise adaptée au pays ou à la zone d’utilisation à
l’autre extrémité
Fréquence d’alimentation
Températures
50/60 HZ
°
°
10 C à 50 C en fonctionnement
°
°
-20 C à 60 C hors fonctionnement
Humidité
Fonctionnement : 20 à 80 % sans condensation
Hors fonctionnement : 5 à 95 % sans condensation
Agréments et labels de sécurité et EMC
UL, FCC, cUL, ICES, CE, N, GS, IRAM, GOST, VCCI, MIC, C-Tick
Download from Www.Somanuals.com. All Manuals Search And Download.
42
Guide d’installation et d’utilisation du commutateur AutoView 2000
Annexe C : Assistance technique
Notre équipe d’assistance technique se tient à votre disposition en cas de problème d’installation ou
de fonctionnement susceptible de se produire avec un produit Avocent. Si vous rencontrez une
difficulté, suivez la procédure ci-après afin de bénéficier d’une aide le plus rapidement possible.
Remédier à un problème :
1. Vérifiez la section appropriée du manuel pour voir si le problème peut être résolu à l’aide des
procédures indiquées.
7. Consultez le site www.avocent.com/support et effectuez une recherche dans la base de
connaissances ou utilisez le formulaire d’aide en ligne.
8. Appelez le service d’assistance technique Avocent le plus proche.
Download from Www.Somanuals.com. All Manuals Search And Download.
43
INDEX
A
Ajout de commutateurs classiques 10
Annexes 35
Assistance technique 42
B
Boîte de dialogue AVRIQ Selection
(Sélection AVRIQ) 27
Boîte de dialogue Broadcast (Diffusion) 32
Boîte de dialogue Broadcast Enable
(Activer diffusion) 33
Boîte de dialogue Commands (Commandes) 29
Boîte de dialogue Device Modify
(Modif. équip.) 20
E
Boîte de dialogue Devices (Équipements) 20
Boîte de dialogue Flag (Indicateur) 22
Boîte de dialogue Menu 21
Boîte de dialogue Name Modify (Modifier nom) 19
Boîte de dialogue Names (Noms) 18
Boîte de dialogue Scan (Balayage) 28
Boîte de dialogue Security (Sécurité) 24
Boîte de dialogue Setup (Configuration) 17
Boîte de dialogue Switch (Commutateur) 34
Boîte de dialogue Version 26
F
Fonction Keep Alive 1
I
Identification électronique (EID) 1, 2
Indicateur d’état 22
Interface OSCAR 2, 13
M
C
Message d’avertissement diagnostics 31
Mesures de sécurité 3
Mise à jour FLASH 2, 35
Mode de commutation
CAT 5 1
Commutateur AutoView 2000
ajout de commutateurs classiques 10
chargement du rack 6
modification 33
Modes de fonctionnement 2
Modification du mot de passe 24
configuration en cascade 1, 8
éléments inclus dans la livraison 5
fonctions 1
montage des supports 6
Download from Www.Somanuals.com. All Manuals Search And Download.
44
AutoView 2000 Guide d’installation et d’utilisation
Module AVRIQ 1
Serveurs
ajout à la liste de balayage 28
connexion au serveur 7
mise à jour 36
attribution de noms 18
Montage des supports du commutateur 6
Montage en rack 5
configuration en vue d’une commutation
logicielle 15
déconnexion 15
diffusion 31
sélection 14
N
Navigation dans l’interface OSCAR 15
sélection d’un serveur par commutation
logicielle 15
visualisation et sélection 13
Set Position (Fixer position) 23
Suppression de la protection par mot de passe 25
Système de balayage 27
P
Protection par un mot de passe 24
R
Réglage du retard d’affichage 21
S
V
Sécurité de la console 23
Vidéo SVGA 2
Vidéo VGA 2
Vidéo XGA 2
Voie ARI 13
Sécurité relative au montage en rack 4
Download from Www.Somanuals.com. All Manuals Search And Download.
GARANTIE LIMITÉE
Avocent Corporation garantit à l’acheteur initial que ce produit est et sera exempt de défaut de matériau et de
fabrication pendant une période de 24 mois à compter de la date d’achat.
De plus, tous les produits Avocent sont accompagnés d’une garantie inconditionnelle de satisfaction de trente
jours. Si, pour quelque raison que se soit, vous n’êtes pas satisfait des performances de ce produit, vous pouvez
le renvoyer au point de vente et vous faire rembourser le prix d’achat (hors frais d’expédition). Cette garantie ne
s’applique pas aux produits faisant l’objet de commandes spéciales et peut ne pas être disponible auprès de tous
les revendeurs. Pendant la période de garantie, l’acheteur doit impérativement contacter Avocent afin d’obtenir
un numéro d’AUTORISATION DE RENVOI DU PRODUIT (ARP). Assurez-vous que ce numéro figure sur le
bordereau d’emballage, sur la preuve d’achat ET SUR L’EXTÉRIEUR DE CHAQUE CARTON D’EXPÉDITION.
Les renvois non autorisés et les expéditions en port dû seront refusés.
Expédiez en port payé à :
Avocent Corporation
4991 Corporate Drive
Huntsville, Alabama 35805 USA
Téléphone : (256) 430-4000
La garantie limitée présentée ci-dessus est nulle et non avenue dans l’une quelconque des situations suivantes,
auquel cas le produit est fourni tel quel, avec tous ses défauts et toutes les stipulations d’exonération de garantie
énoncées ci-dessous :
1. Si le défaut ou le mauvais fonctionnement résulte d’un emploi abusif, d’une mauvaise manipulation, d’une
réparation non autorisée ou d’un usage autre que celui pour lequel le produit a été conçu.
2. Si des modifications non autorisées ont été apportées au produit.
3. Si des dommages se sont produits lors de l’expédition et n’ont pas été signalés.
4. Si des dommages ont été provoqués par un équipement ou un logiciel non fourni par Avocent.
5. Si l’appareil est utilisé avec une alimentation en courant alternatif non reliée à la masse ou mal polarisée.
6. Si le produit n’est pas utilisé conformément aux instructions du guide d’utilisation ou de la feuille
d’instructions fournie avec le produit.
7. Si le produit est endommagé en raison de surtensions, d’expositions à l’eau ou de catastrophes naturelles,
y compris la foudre.
SOUS RÉSERVE DES DISPOSITIONS SPÉCIFIQUEMENT STIPULÉES CI-DESSUS ET DANS LES LIMITES
AUTORISÉES PAR LA LOI, AVOCENT DÉCLINE TOUTES LES GARANTIES ET CONDITIONS, QU’ELLES
SOIENT EXPRESSES, IMPLICITES OU STATUTAIRES, SUR QUELQUE POINT QUE CE SOIT, Y COMPRIS
NOTAMMENT, LE TITRE, L’ABSENCE DE CONTREFAÇON, L’ÉTAT, LA QUALITÉ MARCHANDE OU
L’ADAPTATION À UN USAGE PARTICULIER OU PRÉVU.
SOUS RÉSERVE DES DISPOSITIONS EXPLICITÉES CI-DESSUS ET DANS LES LIMITES AUTORISÉES
PAR LA LOI, AVOCENT CORPORATION NE SERA PAS TENU RESPONSABLE DE TOUS LES DOMMAGES
PARTICULIERS, INDIRECTS OU CONSÉCUTIFS (Y COMPRIS NOTAMMENT, LE MANQUE À GAGNER, LES
PERTES COMMERCIALES, LA PERTE D’INFORMATIONS, LES PERTES FINANCIÈRES, LES PRÉJUDICES
CORPORELS, LA PERTE DE CONFIDENTIALITÉ OU LA NÉGLIGENCE) POUVANT ÊTRE, DIRECTEMENT
OU INDIRECTEMENT, CAUSÉS PAR OU LIÉS À L’UTILISATION D’UN PRODUIT OU D’UN SERVICE,
L’IMPOSSIBILITÉ D’UTILISER UN PRODUIT OU UN SERVICE, L’INADÉQUATION D’UN PRODUIT OU
D’UN SERVICE, QUEL QUE SOIT L’USAGE OU L’APPLICATION QUI EN EST FAIT OU TOUT DÉFAUT OU
INSUFFISANCE ET CE, MÊME SI AVOCENT CORPORATION OU UN REVENDEUR AGRÉÉ PAR AVOCENT
ONT ÉTÉ INFORMÉS DE LA POSSIBILITÉ DE TELS DOMMAGES OU PERTES.
© 2004 Avocent Corporation. Tous droits réservés.
Download from Www.Somanuals.com. All Manuals Search And Download.
For Technical Support:
Visit www.avocent.com/support
Avocent International Ltd.
Avocent House, Shannon Free Zone
Shannon, County Clare, Ireland
Tel: +353 61 715 292
Avocent Corporation
4991 Corporate Drive
Huntsville, Alabama 35805-6201 USA
Tel: +1 256 430 4000
Fax: +353 61 471 871
Fax: +1 256 430 4031
Avocent Germany
Gottlieb-Daimler-Straße 2-4
D-33803 Steinhagen
Germany
Avocent Asia Pacific
Singapore Branch Office
100 Tras Street, #15-01
Amara Corporate Tower
Singapore 079027
Tel: +49 5204 9134 0
Fax: +49 5204 9134 99
Tel: +656 227 3773
Fax: +656 223 9155
Avocent Canada
20 Mural Street, Unit 5
Richmond Hill, Ontario
L4B 1K3 Canada
Tel: +1 877 992 9239
Fax: +1 877 524 2985
590-284-116C