TEST
PutON-TIMEswitchonthesensorbottomto
TEST and the Dual Light Level (ACCENT)
switch OFF.
ON-TIME
ACCENT
GUARDIAN
PRO™
TEST 1 5 20
Off 3 6 Dusk to Dawn
POST SENTRY
AUTO
Model PLMS
Set ON-TIME switch to
1, 5, or 20 minutes.
TEST 1 5 20 MIN
Features
• Light comes on when motion is detected.
• Automatically controls existing post light.
• Dual Light Level.
• Photocell keeps the light off during day-
light hours.
MANUAL MODE
Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
This package includes:
Flipthelightswitchoffforone
secondthenbackontotoggle
betweenAUTOandMANUAL
MODE.
1 Second
OFF then...
Manual mode works only with
the ON-TIME switch in the 1,
5, or 20 position.
Post Light
3 Screws
Adapter
... back on.
Mode Switching Summary
TEST
ON-TIME Switch at
3 Wire Connectors
1, 5, or 20 minutes
AUTO
Requirements
Flip light switch
off for 1 second
• The Light Control requires 120 volts AC.
• If you want to use Manual Override, the
control must be wired through a switch.
• Some codes require installation by a
qualified electrician.
MANUAL MODE
then on
* If you get confused while switching modes,
turnthepoweroffforoneminute,thenback
on. After the calibration time the control will
be in the AUTO mode.
OPERATION
Mode:
On-Time
Works: Day Night
Dual Light Level Control
Light comes on half bright for selected time
after dusk (Off, 3 hr., 6 hr., until dawn). If
motion is sensed, the light turns on full bright
for the ON-TIME (1, 5, or 20 minutes) then
returns to dim mode.
Test
Auto
5 Sec
1, 5, or 20 Min
To Dawn*
x
x
x
x
x
Manual
Accent 3,6 Hr, to Dawn
* resets to Auto Mode at dawn.
240-031-A
© 2003 Atlas Lighting Products, Inc.
598-1095-01
Download from Www.Somanuals.com. All Manuals Search And Download.
❒
❒
When you have the desired coverage
angle make a pencil mark on the sensor
and post to mark the sensor position.
If you need to change the sensitivity,
temporarily lift the fixture and sensor to
make the adjustment. It may be neces-
sary to have a friend hold the fixture
whileadjustingthesensitivity. Toomuch
sensitivity may increase false triggering.
SettheamountofONTIMEyouwantthe
light to stay on after motion is detected.
(1, 5, or 20 minutes).
ADJUSTMENTS
❒
Turn on the circuit breaker and light
switch.
1
NOTE: Sensor has a 1 /2 minute warm up
periodbeforeitwilldetectmotion.When
first turned on or when switching from
Manual to Auto mode wait 1 1/2 minute.
❒
Avoid aiming the control at:
• Objects that change temperature rapidly,
such as heating vents and air condition-
ers. These heat sources could cause false
triggering.
• Areaswherepetsortrafficmaytriggerthe
control.
• Nearby large, light-colored objects
reflectinglightmaytriggertheshut-offfeature.
Do not point other lights at the sensor.
OFF 3
6
DUSK TO
TEST 1 5 20 MIN
HOUR DAWN
❒
Set the Dual Light Level (ACCENT)
switch to the amount of time after dusk
you want the lights on at low level (Off, 3,
6 Hrs., Dusk-to-Dawn).
❒
Put the sensor and fixture back in place.
Alignthepencilmarksmadeabove.Tighten
the three screws to secure the sensor.
150°
Securing Brass &
Plastic Post Lamps
5 ft.
(1.5 m)
❒
❒
Turn power off at circuit breaker.
Turn the post lamp to the desired loca-
tion. Using a #31 drill and the fixture as
a template slightly mark the location of
one of the fixture mounting holes. DO
NOT drill through the sensor plastic.
Lift the fixture off the sensor and keep
the wires away from where you need to
drill. Now finish drilling the first hole.
Set the fixture in position and install a
screw (provided) to hold the fixture.
Mark the remaining holes as above.
Removetheonescrewandliftthefixture
and drill the remaining holes as above.
Set the fixture in position and install all the
screws(3provided). Becarefultonotover
tightenthescrewsandstripouttheplastic.
30 ft.
(9.1 m)
Maximum
Range
Maximum
Coverage Angle
Thedetectorislesssensitivetomotiondirectly
towardsitandmoresensitivetoacrossmotion.
❒
❒
Motion
Motion
❒
❒
Sensor
Least Sensitive
Most Sensitive
❒
❒
Walk through the coverage area noting
where you are when the lights turn on.
Loosen the 3 clamp screws slightly and
turn the sensor head left or right to
change the coverage area.
598-1095-01
3
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE
If you experience a problem with your Light Control, first follow this guide. For additional assistance write to:
Atlas Lighting Products, Inc. • Customer Service Department • P.O. Box 2348 • Burlington, NC 27216
SYMPTOM
POSSIBLE CAUSE
SYMPTOM
POSSIBLE CAUSE
Light will
not come
on.
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker is
turned off.
4. Daylight turnoff is in effect (Re-
check after dark).
5. Incorrect circuit wiring, if this is a
new installation.
6. Re-aim the sensor to cover de-
sired area.
Light stays on 1. The sensor is pointed at nearby
continuously.
objectsthatcauseheattotrigger
the sensor. (Aim the sensor
away from nearby objects).
2. The sensor is pointed toward a
heat source like an air vent,
dryer vent, or brightly-painted
heat-reflectivesurface.(Re-aim
sensor).
Light flashes
on and off.
1. Heat being reflected from other
objects may be affecting the
sensor. (Re-aim sensor).
Light comes 1. Light Control may be installed in
on in
a relatively dark location.
daylight.
2. LightControlisinTest.(Setcontrol
switch to an ON-TIME position).
2. LightControlisintheTestmode
and warming up. (Flashing is
normalundertheseconditions).
Light comes 1. Light Control may be sensing
on for no
apparent
reason.
small animals or automobile traf-
fic (Re-aim sensor).
2. Sensitivity is set too high. (Re-
duce sensitivity).
FIVE YEAR LIMITED WARRANTY
AtlasLightingProducts,Inc.warrantsagainstdefectsinmaterialsorworkmanshipforaperiodoffiveyearsfrom
the date of purchase for use, and agrees to repair or, at our option, replace a defective unit without charge for
either parts or labor. IMPORTANT: This warranty does not cover damage resulting from accident, misuse of
abuse, lack of reasonable care, the affixing of any attachment not provided with product, alteration of any
attachments factory installed, loss of parts or subjecting the fixture to any but the specified electrical service.
Thiswarrantydoesnotcoverfailureofthebulbduetoaccidents, abuse, misuse, vandalism, powersurges, and
acts of nature such as lightning damage. No responsibility is assumed for any special incidental or
consequential damages. Damages occurring during transit are not covered by this warranty-including UPS
shipments. To obtain warranty service, mail sales receipt as proof-of-purchase, date and a brief explanation
of the nature of the defect, to the address listed below. You will receive, by mail, a Return Goods Authorization
number and full instructions for returning defective merchandise. All returned goods must be accompanied
by a Return Goods Authorization number issued by Atlas Lighting Products, Inc.
NOTE: No other warranty, written or verbal, is authorized by Atlas Lighting Products, Inc. This warranty gives
you specific legal rights and you may also have other rights which vary from state to state. Some states do not
allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied
warranty lasts, so the above exclusion and limitations may not apply to you.
For information regarding replacement parts please write to:
Atlas Lighting Products, Inc.
Attn: Customer Service Department
P.O. Box 2348
Burlington, NC 27216
598-1095-01
4
Download from Www.Somanuals.com. All Manuals Search And Download.
|