American Standard Plumbing Product 705205 User Manual

SELECTRONIC®  
7055.105 7055.205  
7055.115 7055.215  
7056.105 7056.205  
7056.115 7056.215  
Proximity Integrated Faucet  
with Optional Above-Deck Mixing  
• Flexible Selectronic® Platform with Universal Sensor  
• Easy installation. All electronics in the spout; nothing below deck.  
• User adjustable above-deck mixing uses ceramic disc  
valve for dependability & long life  
• Mixing handle can be removed for one time temperature  
setting during installation  
• Available in DC (Battery) & AC versions  
Product No.'s & Options  
Specifications  
How to Install  
Maintenance  
FAQ,s  
1
2
2-3  
3-7  
7-8  
8
Certified to comply with ASME A112.18.1M  
Replacement Parts  
© 2012 American Standard  
M965255 REV. 1.6  
NOTE TO INSTALLER: Please give this manual to the customer after installation.  
To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com  
or U.S. customer's e-mail us at: [email protected]  
For Parts, Service, Warranty or other Assistance,  
please call 1-800-442-1902 (In Canada: 1-800-387-0369)  
(In Toronto Area only: 1-905-3061093)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Roughing-in Dimensions  
Fig. 1  
191mm  
(7-1/2)  
FINISHED WALL  
OR BACKSPLASH  
MIN. 1" CLEARANCE  
191mm  
(7-1/2)  
165mm  
(6-1/2)  
140mm  
(5-1/2)  
MOUNTING  
SURFACE  
66mm  
( 2-5/8)  
38mm  
(1-1/2 )  
32mm (1-1/4)  
GENERAL DESCRIPTION:  
Electronic faucet with proximity operation. Vandal  
resistant solid brass construction single post mounting.  
Operates on DC (battery) or AC power. Inlets 3/8"  
compression, built-in checks, flexible stainless steel 18"  
reach inlet hoses for spout connection and In-line  
integral strainer for solenoid.  
457mm  
(18)  
3/8" COMPRESSION  
CONNECTORS  
Fig. 2  
TOOLS REQUIRED; Fig. 2  
1
1 Hex Wrench (Included)  
2 Adjustable Wrench  
4 Phillips Screwdriver  
5 Tape Measure  
2
3
4
3 Plumbers' Putty or Caulking  
5
10'  
INSTALLATION  
INSTALL SPOUT ASSEMBLY;  
1
Fig. 1  
Turn off hot and cold water  
CAUTION  
Fig. 1  
supplies before beginning  
1. Make sure O-RING SEAL (9) is installed.  
2. Installation with ESCUTCHEON (1) (optional).Apply a  
bead of putty to bottom edge of ESCUTCHEON with PUTTY  
PLATE (1). (Only if mounting surface is uneven).  
IMPORTANT: Do not  
use putty when installing  
faucet without escutcheon.  
7
PUTTY  
(If required)  
3. Insert supply HOSES (2), SHANK (3) and POWER CORD  
(10) (if equipped) through hole in ESCUTCHEON with PUTTY  
PLATE (1) and mounting surface. Follow mounting  
instructions below to secure faucet to mounting surface.  
(Make sure PIN (7) is in back).  
9
3
(OPTIONAL)  
1
MOUNTING  
SURFACE  
4. Installation less ESCUTCHEON (1). IMPORTANT: Do not  
use putty when installing faucet without escutcheon.  
10  
Fig. 1a  
5. Assemble RUBBER WASHER (4), BRASS WASHER  
(5) and THREADED LOCKNUT (6) onto SHANK (3) from  
underside of sink or mounting surface. Hand tighten  
LOCKNUT (6).  
TIGHTEN  
SPIN NUTS  
2
6. Use a screwdriver to tighten SCREWS (8) on  
LOCKNUT (6). Work your way around LOCKNUT (6),  
tightening the screws slightly each time until all are snug  
to ensure even pressure.  
4
5
6
8
1
CONNECT POWER SUPPLY; Fig. 1a  
2
2
(7056 series only)  
1. Connect the sensor cable (1) to the POWER SUPPLY  
3
CABLE (2).  
2. Code approved Electrical Outlet provided by others.  
(120V 50/60 Hz)  
ELECTRICAL OUTLET  
(120V 50/60 Hz)  
3. Plug AC POWER SUPPLY (3) into Outlet.  
M965255 REV. 1.6  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAKE WATER SUPPLY  
3
Fig. 2  
CONNECTIONS; Fig. 2  
1. Turn off hot and cold water supplies before  
beginning.  
2. Connect HOSE ADAPTERS (3) to wall supplies (if  
required). Connect FLEXIBLE SUPPLIES (1, 2) directly  
to HOSE ADAPTERS (3).  
2
1
3. Connect left supply (Marked with a Red Stripe) to  
Hot and right supply (Marked with Blue Stripe) to Cold  
supply. Use adjustable  
3
SEAL  
WASHER  
wrench to tighten connections. Do not over tighten.  
(SUPPLIED)  
HOT  
4. Faucet supplies are 18" long from faucet base.  
COLD  
Note; If additional supply length is required,  
installer must purchase those parts separately.  
Important; If SUPPLY HOSES (1, 2) are too long,  
loop as illustrated to avoid kinking.  
Fig. 3  
SELECTRONIC™  
Thermostatic Mixing Valve  
605XTMV  
INSTALL OPTIONAL MIXING  
4
VALVE; Fig. 3  
For 7055.105/115 & 7056.105/115 Faucets.  
Note; For complete detailed installation and  
operating instructions see installations  
instructions supplied with mixing valve.  
No. M968808  
Speci!cations  
Installation  
1
2
3
3
4
Adjust Temperature  
Service  
Replacement Parts  
Certified to comply with ASME A112.18.1M  
2005 American Standard  
©
M968808  
No. M968808  
NOTE TO INSTALLER: Please give this manual to the customer after installation.  
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.  
customer's e-mail us at: [email protected]  
For Parts, Service, Warranty or other Assistance,  
please call 1-800-442-1902 (In Canada: 1-800-387-0369)  
(In Toronto Area only: 1-905-3061093)  
Fig. 1  
MAINTENANCE  
DETECTION  
ZONE  
HANDWASHSENSOROPERATION;  
1
Fig. 1  
REMOVE PROTECTIVE FILM FROM SENSOR EYE  
WHEN INSTALLATION IS COMPLETE.  
PROTECTIVE FILM  
When the Sensor detects a user, the water  
immediately starts to flow. Water flow will stop two  
seconds after user is out of sensor range. The off delay  
allows the user to comfortably move his hands without  
the flow cycling on to off. As a precaution, a safety  
timer will turn off the water, after the sensor has been  
blocked for 59 seconds. The water will stay off until the  
blockage is removed from the detection zone.  
Detection Zone: 2" - 10" (50.8mm - 254mm)  
Default: Set at Factory 6" (152.4mm)  
M965255 REV. 1.6  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
HOW TO CHANGE SENSOR  
Fig. 2  
RANGE; (Factory set at 6") Fig. 2  
1. Setting the Detection Zone (Distance):  
Remove the FAUCET COVER (1) by unthreading the  
LEVER SCREW (2) and pulling off the LEVER  
HANDLE (3). Unthread the FAUCET COVER SCREW  
(4) at the back of the FAUCET. Pull FAUCET COVER  
(1) up and off. Fig. 2.  
REMOVE  
1
REPLACE  
2. Disconnect the BLACK POWER SUPPLY  
CONNECTOR (1) and reconnect. Fig. 3.  
3
2
4
3. While the SENSOR CONTROL LED (2) is blinking  
slowly, place your hand 1 - 2 in. (25.4-50.8mm) in front  
of the sensor. Fig. 4.  
4. When the LED stops blinking and stays "ON", move  
your hand to the desired position and hold in place until  
the LED begins to blink again. Fig. 4a.  
5. Once the SENSOR CONTROL LED (2) begins to  
blink again, remove your hand from the detection zone.  
When the flashing stops, the detection distance is set.  
Fig. 3  
1
6. Replace FAUCET COVER (1) and LEVER HANDLE  
(3). Install LEVER HANDLE SCREW (2), FAUCET  
COVER SCREW (4) and tighten. Fig. 2.  
Fig. 4  
Fig. 4a  
1"-2"  
(25.4mm-  
50.8mm)  
UP TO 10"  
(254mm)  
2 BLINKING LED  
2 BLINKING LED  
M965255 REV. 1.6  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
HOW TO INSTALL AND CHANGE  
Fig. 5  
BATTERY; Fig. 5  
1. Remove the FAUCET COVER (1) by unthreading the  
LEVER SCREW (2) and pulling off the LEVER  
HANDLE (3). Unthread the FAUCET COVER SCREW  
(4) at the back of the FAUCET. Pull FAUCET COVER  
(1) up and off. See Fig. 2 in this section.  
1
2
2. Remove BATTERY HOLDER (1) from FAUCET  
BODY (2).  
3. Remove old battery from the BATTERY HOLDER (1).  
4. Install NEW BATTERY (3) into the BATTERY  
HOLDER (1). Replace BATTERY HOLDER (1) into the  
FAUCET BODY (2).  
3
5. Replace FAUCET COVER (1) and LEVER HANDLE  
(3). Install LEVER HANDLE SCREW (2), FAUCET  
COVER SCREW (4) and tighten. See Fig. 2 in this  
section.  
Fig. 6  
4
HOW TO REPLACE SENSOR;  
Fig. 6, 7, & 8.  
1. Remove the FAUCET COVER (1) by unthreading the  
LEVER SCREW (2) and pulling off the LEVER  
HANDLE (3). Unthread the FAUCET COVER SCREW  
(4) at the back of the FAUCET. Pull FAUCET COVER  
(1) up and off. See Fig. 2 in this section.  
DISCONNECT  
WIRE CONNECTIONS  
2. Disconnect both WIRE CONNECTIONS. Fig. 6.  
3. Untighten SENSOR SCREW (1) with a 2.5mm HEX  
WRENCH. Remove SENSOR ASSEMBLY (2) from  
FAUCET BODY (3). Remove SENSOR (2a) from  
CARRIER (4) and replace with new SENSOR (2a).  
Install SENSOR ASSEMBLY (2) into FAUCET BODY  
(3). Tighten SENSOR SCREW (1). Fig. 7, 8.  
4. Replace FAUCET COVER (1) and LEVER HANDLE (3).  
Install LEVER HANDLE SCREW (2), FAUCET COVER  
SCREW (4) and tighten. See Fig. 2 in this section.  
Fig. 7  
Fig. 8  
4
2
3
2a  
2.5mm HEX  
WRENCH  
1
M965255 REV. 1.6  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
HOWTO CLEAN FILTER SCREEN  
Fig. 9  
ON SOLENOID VALVE; Fig. 9 & 10  
1. Remove the FAUCET COVER (1) by unthreading the  
LEVER SCREW (2) and pulling off the LEVER  
HANDLE (3). Unthread the FAUCET COVER SCREW  
(4) at the back of the FAUCET. Pull FAUCET COVER  
(1) up and off. See Fig. 2 in this section.  
DISCONNECT  
WIRE CONNECTION  
1
2. Disconnect WIRE CONNECTION (1) to SOLENOID  
VALVE (2). Fig. 9.  
3. Unthread SOLENOID VALVE (2) from VALVE BODY  
(3). Fig. 9.  
4. Remove FILTER SCREEN (4) from base of  
SOLENOID VALVE (2). Rinse clean and replace. Fig. 10.  
2
3
5. Thread SOLENOID VALVE (2) into VALVE BODY (3)  
and hand tighten. Reconnect WIRE CONNECTION (1).  
Fig. 9.  
Fig. 10  
4
2
6. Replace FAUCET COVER (1) and LEVER HANDLE  
(3). Install LEVER HANDLE SCREW (2), FAUCET  
COVER SCREW (4) and tighten. See Fig. 2 in this  
section.  
6
HOWTO REPLACE DIVERTER  
Fig. 11  
2
3
CARTRIDGE; Fig. 11 & 12  
1. Remove the FAUCET COVER (1) by unthreading the  
LEVER SCREW (2) and pulling off the LEVER  
HANDLE (3). Unthread the FAUCET COVER SCREW  
(4) at the back of the FAUCET. Pull FAUCET COVER  
(1) up and off. See Fig. 2 in this section.  
9
8
1
2. Pull out LIMITER STOP (1) from the VALVE STEM  
(2). Unthread COLLAR NUT (3) from VALVE BODY (4).  
Fig. 11.  
4
3. Pull DIVERTER CARTRIDGE (5) out and replace  
with new DIVERTER CARTRIDGE (5).  
NOTE: Make sure the two ALIGMENT PINS (6) in the  
base of the DIVERTER CARTRIDGE (5) are facing  
upward.  
Fig. 12  
6
4. Replace FAUCET COVER (1) and LEVER HANDLE  
(3). Install LEVER HANDLE SCREW (2), FAUCET  
COVER SCREW (4) and tighten. See Fig. 2 in this  
section.  
5
M965255 REV. 1.6  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
CHANGE HOT LIMIT SETTING  
FROM 95%TO 85%; Fig. 13  
2
3
1. Remove the FAUCET COVER (1) by unthreading the  
LEVER SCREW (2) and pulling off the LEVER  
HANDLE (3). Unthread the FAUCET COVER SCREW  
(4) at the back of the FAUCET. Pull FAUCET COVER  
(1) up and off. See Fig. 2 in this section.  
9
2. Replace LEVER HANDLE and rotate  
counter-clockwise to its stop position (100% cold).  
Remove HANDLE.  
8
SLOT  
3. Pull out LIMITER STOP (1) from the VALVE STEM (2).  
4. Rotate LIMITER STOP (1) 180 degrees and insert  
back onto VALVE STEM (2).  
ROTATE 180˚  
SLOT  
1
Fig. 13  
5. Replace FAUCET COVER (1) and LEVER HANDLE  
(3). Install LEVER HANDLE SCREW (2), FAUCET  
COVER SCREW (4) and tighten. See Fig. 2 in this  
section.  
GENERAL CLEANING; Fig. 14  
8
1. For general cleaning use a damp, soft cloth to clean  
the spout and the sensor.  
2. For cleaning dirt use a soft cloth with diluted dish  
washing detergent. Wipe the area using a wet cloth  
and dry using a soft cloth.  
CAUTION  
Do not scratch the sensor when cleaning.  
Avoid using anything that may scratch the spout  
surface. Never use polishing power, detergent or a  
nylon scrub brush. They will damage the surface of the  
spout or Sensor.  
Fig. 14  
FAQ'S  
Q: How will I know if battery needs to be replaced?  
A: Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.  
Q: Why has the flow rate of the faucet reduced significantly?  
A: Check and clean aerator and strainer.  
Q: There is no flow out of faucet when I'm in the sensor range?  
A: Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1 800-442-1902.  
Q: What is the normal operating pressure range?  
A: Faucet will operate with supply pressures ranging from 20-80 psi.  
M965255 REV. 1.6  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SELECTRONIC  
Proximity Integrated Faucet  
with Above-Deck Mixing  
PRODUCT NUMBERS  
7055.105  
7055.115  
7055.205  
7055.215  
M900540-0020A  
FAUCET COVER  
(LESS MIXING)  
7056.105  
7056.115  
7056.205  
7056.215  
M900541-0020A  
FAUCET COVER  
(FOR MIXING VALVE)  
A912790-0070A  
VALVE STEM O-RINGS  
A923654-0070A  
BATTERY 6VCR-P2  
M964171-0070A  
1.5 GPM AERATOR  
M964172-0070A  
0.5 GPM AERATOR  
M950514-0070A  
BATTERY HOLDER  
M964188-0070A  
COLLAR NUT &  
TEMPERATURE  
LIMITER STOP  
M954483-0070A  
SOLENOID VALVE  
M964187-0020A  
LEVER ASSEMBLY  
M951479-0070A  
DIVERTER CARTRIDGE  
M964173-007LOA  
SENSOR  
M911785-0070A  
SPOUT O-RING  
M920013C-0070A  
COLD SUPPLY HOSE  
M920013H-0070A  
HOT SUPPLY HOSE  
M950317-0070A  
AC POWER SUPPLY  
M964333-0070A  
HOSE ADAPTER  
705P400  
ESCUTCHEON  
HOT LINE FOR HELP  
For toll-free information and answers to your questions, call:  
1 (800) 442-1902  
M962146-0070A  
MOUNTING KIT  
Weekdays 8:00 a.m. to 8:00 p.m. EST  
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)  
Weekdays 8:00 a.m. to 7:00 p.m. EST  
Product names listed herein are trademarks of American Standard Inc.  
© American Standard Inc. 2012  
M965255 REV. 1.6  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

3M Food Saver 800af s User Manual
3M Switch VOL 1081 User Manual
Access Handheld TV PTV 7000 User Manual
Acer Laptop 3240 Series User Manual
Air King Vacuum Cleaner CVEK3000 User Manual
Airlink101 Network Router AR686W User Manual
Altec Lansing Speaker 5181 XM User Manual
Amana Oven ARR6102 User Manual
Ativa Portable Speaker PF112 User Manual
Beko Freezer HS222540 User Manual