American Standard Plumbing Product 45084 User Manual

Installation  
Instructions  
4508.400  
PRINCETON  
Bidet Faucet and Transfer Valve with  
Speed Connect™ Drain  
Congratulations on purchasing your American Standard  
faucet with Speed Connect drain, a feature found only on  
American Standard faucets.  
Certified to comply with ANSI A112.18.1  
M968845 Rev. 1.2  
Speed Connect™ Drain*  
• Fewer parts, installs in less time  
• Never needs adjustment  
• Guaranteed to seal properly the first time, every time.  
*Your new American Standard faucet is designed to work only with the Speed Connect drain.  
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.  
Required tools  
Roughing-in  
8 TO 12  
FINISHED  
WALL  
TRANSFER VALVE  
Dimensions  
(FOR FLUSHING  
RIM OR SPRAY)  
BIDET OUTLINE  
IS SYMBOLIC  
2-1/4  
DIA.  
(C)  
(H)  
7/8 DIA.  
Plumbers' Putty or  
Caulking  
Screwdriver  
1-3/16  
DIA.  
DOUCHE  
SPRAY  
2-1/8  
DIA.  
4-1/4  
ADJ. 1-1/4  
TO 2-1/4  
1-1/4  
MAX.  
Phillips Screwdriver  
1-3/8  
DIA.  
FOR GROUND JOINT  
CONNECTION OR 1/2 "  
O.D. SLIP (INLETS)  
Channel Locks  
Tubing Cutter  
3-7/8  
REAR VIEW WITH  
WALL REMOVED  
FINISHED  
FLOOR  
5-1/2  
Adjustable Wrench  
1-1/4 O.D. TAILPIECE  
Turn off hot and cold water  
supplies before beginning.  
BIDET FAUCET INSTALLATION CAUTION  
1
2
6
7
Place RUBBER RING (10) into ESCUTCHEON (4).  
Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From  
under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting  
holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above  
mounting surface top. Fig. A. Thread DECK ADAPTER (4) onto VALVE BODIES  
(3, 3a) until snug against internal stop. If necessary, adjust LOCKNUT (1).  
4
BIDET  
LEDGE  
10  
8
Tighten LOCKNUTS (1) with WRENCH (5) (supplied)  
to secure VALVE BODIES (3, 3a).  
4
10  
Fig. A.  
Remove ESCUTCHEON (6), WASHER (7) and  
UPPER GASKET (8) from TRANSFER VALVE (9).  
Insert TRANSFER VALVE (9) into the center forward  
hole of BIDET.  
3a  
5/16''  
MIN.  
MOUNTING  
SURFACE  
3
COLD  
2
1
HOT  
9
2
1
Replace UPPER GASKET (8) and WASHER (7) and  
ESCUTCHEON (6) until it locks against internal stop.  
Position the side threaded outlet rearward and  
secure MOUNTING NUT (11).  
11  
5
3, 3a  
2
8
7
9
1
SPRAY INSTALLATION  
PUTTY  
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside  
of SPRAY BODY FLANGE (2) and secure with NUT (3).  
6
3
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1).  
Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet  
NIPPLE (7) of the TRANSFER VALVE (8).  
5
4
4
Thread SPRAY CAP (9) onto SPRAY BODY (1).  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
ATTACH CABLE  
CONNECTOR  
8
9
Fig. A.  
Fig. B.  
Fig. C.  
DOWN  
POP-UP KNOB (1) must be fully  
down. Fig. A.  
1
Thread CABLE CONNECTOR (1)  
clockwise onto DRAIN BODY  
CONNECTION (2) and hand  
tighten. Fig. B.  
Your new POP-UP DRAIN  
installation is now complete.  
Fig. C.  
2
1-1/4” O.D.  
Note: Tailpeice on pop-up drain  
is 1-1/4” O.D. Fig. C.  
CHECK OPERATION OF POP-UP  
5
4
Operate LIFT KNOB (1) to verify that STOPPER (2)  
opens and closes.  
1
3
1
Note: If STOPPER (2) does not open and close properly  
then refer to the “troubleshooting section” of these  
instructions.  
2
INSTALL DIVERTER KNOB  
2
Push DIVERTER KNOB (1) onto HANDLE ADAPTER (2).  
Push on RING (3) and tighten with SCREW (4).  
Press on KNOB CAP (5).  
Note: Screwdriver gap is for disassembling and should  
point downwards.  
OUTLINE OF BIDET  
TEE AND HOSE CONNECTION  
10  
Insert SEAL (1) into ADAPTER (2) and tighten ADAPTER (2) to  
side of TRANSFER VALVE (3).  
5
6
6
3
Install SEAL (4) into coupling nut of TEE (5) and tighten  
connection to ADAPTER (2).  
7a  
Connect HOSE COUPLING NUTS (6) to Hot and Cold valve  
bodies and securely tighten.  
COUPLING  
NUT  
4
2
1
Front  
9
7
3/8 O.D.  
BULL-NOSE  
RISERS  
1/2" PIPE  
THREAD  
WATER SUPPLY CONNECTION  
COMPRESSION  
NUT  
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT  
INCLUDED AND MUST BE PURCHASED SEPARATELY.  
2
FLEXIBLE  
SUPPLIES  
Connect water supply to VALVE BODIES (7,7a) with  
FERRULE  
1/2" IPS FLEXIBLE SUPPLIES (8) or 3/8" O.D. BULL-NOSE  
RISERS (9). Use adjustable wrench to tighten connections.  
Do not over tighten. Be careful not to kink copper supply when  
bending. Use tubing cutter to cut to proper length.  
COLD  
Connect HOT water supply to inlet of left SHANK and COLD  
water supply to right SHANK using sealant, appropriate  
connectors, and COUPLING NUTS.  
CONNECT TO  
WASTE OUTLET  
3/8 COMPRESSION  
CONNECTION  
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to  
waste outlet.  
HOT  
M968845 Rev. 1.2  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALL HANDLES  
11  
Push ADAPTER (1) on VALVE STEM (2), so that the hole of the  
ADAPTER (1) without a spline is facing up. See figure "A". Tighten  
STEM SCREW (3) to secure ADAPTER (1).  
THREAD ON  
TO DECK  
ADAPTER  
4
Find correct position of LEVER HANDLE ASSEMBLY (4) by adjusting  
male teeth on ADAPTER (1) to female teeth in HANDLE (4).  
TOP  
Thread LEVER HANDLE ASSEMBLY (4) onto DECK ADAPTER (5)  
1
3
2
until snug against mounting surface.  
Figure "A"  
SPLINE END DOWN  
5
OUTLINE OF BIDET  
TEST INSTALLED FITTING  
12  
1
With HANDLES (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
3
Operate both HANDLES (1) to flush water  
lines thoroughly.  
1
Rotate TRANSFER VALVE (5) from rim wash to  
spray several times to check operation.  
CHECK DRAIN CONNECTIONS  
13  
Pull up POP-UP KNOB (3) and fill Bidet with water. Check  
that DRAIN STOPPER (4) makes a good seal and retains  
water in Bidet. If STOPPER (4) does not seal properly,  
please refer to “Troubleshooting Guide” in these instructions.  
4
2
SPRAY  
Push POP-UP KNOB (3) down and check all drain  
connections and "P" trap for leaks.  
if necessary.  
Tighten  
2
SERVICE  
CARE INSTRUCTIONS:  
14  
15  
HANDLE  
ASSEMBLY  
To change direction of handle rotation,  
proceed as follows:  
Turn valve to OFF position. Unthread HANDLE  
BASE (1) from DECK ADAPTER (2).  
Pull HANDLE ASSEMBLY off VALVE STEM (3).  
Remove SPRING CLIP (4). Lift STOP WASHER (5),  
turn 90˚ and replace. Replace SPRING CLIP (4).  
DO: SIMPLY RINSE THE PRODUCT  
CLEAN WITH CLEAR WATER.DRY  
WITH A SOFT COTTON FLANNEL  
CLOTH.  
UNTHREAD  
1
DO NOT: DO NOT CLEAN THE  
PRODUCT WITH SOAPS, ACID,  
POLISH, ABRASIVES, HARSH  
CLEANERS, OR A CLOTH WITH  
A COARSE SURFACE.  
90˚  
Find correct position of HANDLE ASSEMBLY by adjusting  
male teeth on VALVE STEM (3) to female teeth in HANDLE.  
Thread HANDLE ASSEMBLY onto DECK ADAPTER (2)  
3
5
until snug against mounting surface.  
4
If spout drips, operate handles several times from  
OFF to ON position. Do not force - handles turn  
only 90˚ .  
2
M968845 Rev. 1.2  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SpeedConnect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
DOWN  
Fig. A.  
Fig. B. Fig. C.  
CAM  
1
1
RE-ATTACH  
CAM CAP  
STOPPER  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. F.  
Fig. D.  
Fig. E.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M968845 Rev. 1.2  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
LOGO  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF BIDET  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Locked Mode  
(Vandal Proof)  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
LOGO  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
180˚  
LOOP TOWARD  
FRONT OF BIDET  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Unlocked Mode  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M968845 Rev. 1.2  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRINCETON  
BIDET FITTING  
LESS VACUUM BREAKER  
MODEL NUMBER  
M962475-YYY0A  
POP-UP ROD  
4508.400  
M962404-YYY0A  
HANDLE KIT  
M962248-0070A  
DECK ADAPTER KIT  
918428-0070A  
HANDLE SCREW  
M962481-YYY0A  
LIFT ROD GUIDE  
M962182-YYYOA  
HANDLE  
918555-0070A  
HANDLE SCREW  
918049-0070A  
ADAPTER  
923348-0070A  
HANDLE ADAPTER  
994053-0070A  
CARTRIDGE  
033772-0070A  
TEE AND HOSE KIT  
(INCLUDING SEALS)  
013312-YYYOA  
ESCUTCHEON KIT  
M961634-0070A  
VALVE MTG. KIT  
030281-0070A  
TRANSFER VALVE  
MOUNTING KIT  
060463-0070A  
ADAPTER KIT  
953800-0070A  
TRANSFER VALVE  
024220-0070A  
COUPLING NUT  
M962544-YYY0A  
STOPPER  
ASSEMBLY  
M952430-0070A  
CABLE ASSEMBLY  
028645-YYY0A  
BIDET SPRAY  
M962457-007A  
FLANGE  
ASSEMBLY  
072574-0070A  
EXTENSION  
066116-YYY0A  
DRAIN STOPPER  
M922872-0070A  
CAM SEAT INSERT  
M962403-YYY0A  
POP-UP ROD  
066117-YYY0A  
DRAIN FLANGE KIT  
M962430-0070A  
CAM ASSEMBLY  
070847-0070A  
CLIP  
M961711-0070A  
TAILPIECE INSERT  
066118-0070A  
PIVOT ASSEMBLY  
M962458-0070A  
DRAIN MOUNTING KIT  
M961656-YYY0A  
LIFT ROD GUIDE  
030280-0040A  
TAILPIECE WITH  
ESCUTCHEON  
028646-0070A  
SPRAY HOSE  
CONNECTION KIT  
M913207-0070A  
TAILPIECE INSERT  
POP-UP DRAIN AND LIFT ROD ASSEMBLY  
BEFORE 04/06  
M962463-0020A  
TAILPIECE & ESCUTCHEON  
HOT LINE FOR HELP  
For toll-free information and answers to your questions, call:  
1 (800) 442-1902  
Replace the "YYY" with  
appropriate finish code  
Weekdays 8:00 a.m. to 8:00 p.m. EST  
M952426-YYY0A  
DRAIN ASSEMBLY  
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)  
Weekdays 8:00 a.m. to 7:00 p.m. EST  
CHROME  
002  
295  
IN MEXICO 01-800-839-12-00  
SATIN NICKEL  
Product names listed herein are trademarks of American Standard Inc.  
©
AS America, Inc. 2008  
M968845 Rev. 1.2  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

3M Water System AP DWS1000 User Manual
Acer Network Card Series 520 User Manual
ADIC Time Clock 6 00028 01 Rev A User Manual
Aico Smoke Alarm Ei169RF User Manual
American Standard Hot Tub 2470002 User Manual
AMX TV Converter Box AXB VOL3 User Manual
Audiovox Remote Starter APS 995C User Manual
Audiovox Stereo Amplifier PA S2100 User Manual
Avet Reels Fishing Equipment MXJ 6 4 User Manual
Avital Remote Starter 4108L User Manual