American Standard Plumbing Product 192 User Manual

SELECTRONIC®  
Hard-Wired AC Powered Moments  
Lavatory Proximity Faucet  
PRODUCT NUMBERS  
2506.192, 2506.195  
Product No.'s & Options 1  
Specifications  
2
How to Install  
Electrical Hook-up  
Maintenance  
FAQ,s  
2-3  
4-5  
6-7  
8
Replacement Parts  
9
M965274  
NOTE TO INSTALLER: Please give this manual to the customer after installation.  
To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S.  
customer's e-mail us at: [email protected]  
For Parts, Service, Warranty or other Assistance,  
please call 1-800-442-1902 (In Canada: 1-800-387-0369)  
(In Toronto Area only: 1-905-3061093)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 1  
Roughing-in Dimensions  
FINISHED  
WALL  
GENERAL DESCRIPTION:  
154mm  
(6-1/16)  
Electronic faucet with proximity operation. Vandal  
resistant solid brass construction single post  
mounting. Operates on AC permanent power. Water  
pressure range from 20 to 125 psi. In-line strainer  
for solenoid is integral. Single inlet 3/8 compression,  
built-in checks, and flexible stainless steel 15" reach  
inlet hose for spout connection.  
126mm  
(5)  
159mm  
(6-1/4)  
55.5mm  
(2-3/16)  
49mm  
(2)  
32mm (1-1/4)  
Note: All plumbing and electrical wiring must be  
installed in accordance with applicable codes,  
regulations and standards.  
125mm  
(4-7/8)  
CODES AND STANDARDS:  
These products meet or exceed the following  
coded standards:  
114mm  
(4-1/2)  
ELECTRICAL BOX  
OR EQUIVALENT  
BY OTHERS  
ANSI A117.1  
ASME A112.18.1  
381mm  
(15)  
CSA B 125  
NSF 61/Section 9  
500mm  
(20)  
81mm  
(3-3/16)  
ADA Compliant  
3/8" COMP.  
Fig. 2  
TOOLS REQUIRED; Fig. 2  
1 Channel Locks  
2
1
2 Adjustable Wrench  
3 Plumbers' Putty or Caulking  
4 Phillips Screwdriver  
5 Flat Blade Screwdriver  
6 Electric Drill & 1/4" Drill Bit  
7 Tape Measure  
3
7
6
4
5
10'  
INSTALLATION  
Fig. 1a  
INSTALL SPOUT ASSEMBLY;  
1
Fig. 1  
Turn off hot and cold water  
supplies before beginning  
1
CAUTION  
1. Insert WIRES (1), FLEX HOSE (2) and SPOUT  
SHANK (3) through center hole of mounting surface.  
Fig. 1a.  
2
3
2. Assemble "C" WASHER (4), STAR WASHER (5)  
and LOCKNUT (6) onto threads of SPOUT SHANK (7)  
from underside of mounting surface. Fig. 1b.  
Fig. 1b  
7
3. Align FAUCET and tighten LOCKNUT (6). Fig. 1b.  
4
6
5
M965274  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
MOUNT ENCLOSURE; Fig. 2  
2
Fig. 2  
LAVATORY RIM OR  
MOUNTING SURFACE  
1. Determine location of ENCLOSURE (1). It must be  
located with-in the 14" (356mm) by 21" (533mm)  
shaded area shown in Figure 2 in order for electrical  
connections from the spout assembly to be made.  
NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance  
between wall supply and ENCLOSURE (1) must be  
taken into consideration.  
14"  
(356mm)  
ENCLOSURE  
MOUNTING  
HOLES  
SUPPLIES  
WASTE  
1
2-3/4"  
(71mm)  
2. Remove 4 screws from COVER (2) and pull off  
COVER (2). Hold the ENCLOSURE (1) in desired  
location and mark the four mounting hole locations as  
shown. Fig. 2.  
20"  
(500mm)  
21"  
(mm)  
3"  
3-3/4"  
(96mm)  
(76mm)  
MOUNTING HOLES  
3. The ENCLOSURE (1) works best if secured to a wall  
stud or cross brace within the wall, using the SCREWS  
(3) supplied. If the ENCLOSURE (1) is to be installed on  
a tile or plaster wall the ANCHORS (4) and SCREWS  
(3) should be used.  
3
1
2
4
1
4. For installations on drywall or tiled walls; use  
ANCHORS (4) and SCREWS (3) for securing  
ENCLOSURE (1) to finished wall. Drill four 1/4" dia.  
holes a minimum of 1-3/4" deep. Insert the four  
ANCHORS (4) flush with face of the finished wall.  
Align the ENCLOSURE (1) and Install the MOUNTING  
SCREWS (3). Tighten to secure ENCLOSURE (1) to  
mounting surface.  
NOTE: If using Mixing Valve (optional) See Sheet  
#M968808 for installation instructions.  
Fig. 3  
1
CONNECT SPOUT HOSE TO  
3
2
ENCLOSURE; Fig. 3  
1. Connect SUPPLY NUT (1) from spout assembly to  
nipple on top of ENCLOSURE (2). Tighten with  
adjustable wrench to make a water tight connection.  
Fig. 3.  
CONNECT WATER SUPPLY TO  
4
Fig. 4  
ENCLOSURE AND WALL SUPPLY;  
Fig. 4  
1
2
DO NOT USE PIPE  
SEALANT ON THREADS  
NOTE; If using the optional Mixing Valve See Sheet  
#M968808 for installation instructions.  
1. Insert FIBER WASHER (4) into SUPPLY NUT (1) on  
ENCLOSURE (2).  
4
3
2. Connect SUPPLY NUT (1) on ENCLOSURE (2) to  
FLEXIBLE SUPPLY HOSE (3). Tighten to make a  
water tight connection. Use two wrenches to tighten if  
necessary. Fig. 4.  
Fig. 4a  
3. Connect FLEXIBLE SUPPLY (3) directly to wall supply.  
Connection on FLEXIBLE SUPPLY (3) is 3/8"  
compression. Use adjustable wrench to tighten  
connection. Do not over tighten. Fig. 4a.  
4" ELECTRICAL BOX  
OR EQUIVALENT BY  
OTHERS  
Note: FLEXIBLE SUPPLY (3) measures 20" from the  
bottom of the ENCLOSURE (1) base. If additional  
supply length is required, installer must purchase parts  
separately.  
Important: If FLEXIBLE SUPPLY (3) is too long, loop to  
avoid kinking.  
COLD WATER OR  
TEMPERED  
3
WALL SUPPLY  
M965274  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 1  
5
4
1
ELECTRICAL INSTALLATION  
1
ELECTRICAL CONNECTIONS; Fig. 1  
Before opening ENCLOSURE  
CAUTION  
disconnect AC power supply.  
1. Remove ENCLOSURE COVER (1). Fig. 1.  
2. Feed the WIRE CONNECTORS (2) through the top  
of ENCLOSURE (5). Fig. 1a.  
3. Remove GROMMET (4) from ENCLOSURE (5). Fig. 1.  
Fig. 1b  
Fig. 1a  
4"  
7
4. Feed the gray SENSOR WIRE (7) through  
GROMMET (4), 4" from CONNECTOR. Fig. 1b. Insert  
gray SENSOR WIRE (7) into SPLIT PLUG (9). Push  
SPLIT PLUG (9) into GROMMET (4) to seal. Fig. 1d.  
5
4
5. Insert GROMMET (4) back into ENCLOSURE (5).  
Fig. 1c.  
Fig. 1c  
6. Install CIRCUIT BOARD (3) into ENCLOSURE (5)  
with SENSOR WIRE (7) under BOARD. Fig. 1c.  
7
5
4
RED  
7. Insert SENSOR WIRE CONNECTOR (8) and  
EXTENSION WIRE CONNECTOR (11) into available  
CIRCUIT BOARD RECEPTORS (10) slots. Fig. 1e.  
8
3
2
6
BLACK  
8. Connect wires from SENSOR to SOLENOID VALVE  
(6) (Red to +, Black to -). Fig. 1d.  
9. Replace ENCLOSURE COVER (1). Tighten cover  
screws firmly.  
Fig. 1d  
4
9
10. Contractor to supply ELECTRICAL BOX (12)  
and connection to ENCLOSURE (5). Mount POWER  
SUPPLY (13) into ELECTRICAL BOX (12). Connect  
White and Black power connections to POWER  
SUPPLY CABLE (14). Fig. 1f.  
7
11. Connect the EXTENSION WIRE (16) to the  
POWER SUPPLY CABLE (15). FIG. 1f.  
Fig. 1e  
8
Fig. 1f  
10  
11  
10  
4" ELECTRICAL BOX  
OR EQUIVALENT BY  
OTHERS  
12  
16  
15  
14  
BLACK & WHITE  
POWER  
CONNECTOR NOT  
13  
CONNECTIONS  
USED IN THIS  
INSTALLATION  
M965274  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 2  
Unit #1  
Unit #2  
Unit #3  
10  
4
9
4
TWO PIECE  
GROMMET  
6
3
3
1
3
2
1
4"  
1
1
1
5
FOR AC-VERSION  
2
Fig. 3a  
(MULTI HOOK-UP); Fig. 2, 3  
TWO PIECE  
GROMMET  
1. See AC Version Electrical Hook-up for first unit of the  
Multi hook-up.  
8
7
2. Remove ENCLOSURE COVERS from all  
ENCLOSURES.  
3. Remove SOLID BLACK INSERT(1) from right side  
of ENCLOSURE #1 and replace with gray 2-PIECE  
GROMMET (3). Replace solid black inserts on Unit #2  
with gray 2-PIECE GROMMET (3).  
2
4. Take the 10 ft. EXTENSION (2) from Unit #2 and  
install into right side of Unit #1 and Left side of Unit #2  
insealing wire into SPLIT PLUG (7) as shown in Fig. 3a.  
Push SPLIT PLUG (7) into GROMMET (8).  
Feed the gray 8 ft. EXTENSION (2) through ROUND  
GROMMETS (3) and U GROMMETS (5) as illustrated above.  
5. Insert CONNECTOR from 10 ft. EXTENSION (2) into  
CIRCUIT BOARD RECEPTOR (4) top of Unit #1 as  
shown in Fig. 2.  
Fig. 3b  
6. Insert other end of 10 ft. EXTENSION into LOWER  
U GROMMET (5) of Unit #2 (approximately 4" from  
connector). Fig. 3. Push SPLIT PLUG (7) into  
GROMMET (8) to seal.  
2
1
RED  
7. Insert connector of 10 ft. EXTENSION into lower  
receptor as shown in fig. 3 on CIRCUIT BOARD (6) of  
Unit #2.  
3
8. Feed gray sensor wire 9 from Unit #2 through upper  
U GROMMET (10) of Unit #2 ENCLOSURE 4" from  
connector Fig. 3. Insert wire into SPLIT PLUG (7).  
Push SPLIT PLUG (7) into GROMMET (8) to seal. Fig. 3a.  
BLACK  
9. Insert GROMMET (2) back into ENCLOSURE. Fig. 3b.  
10. Reinstall Circuit Board (3) into Enclosure with all  
wires under Board. Fig. 3b.  
11. Connect Unit #2 Red and Black Sensor wires To #2  
solenoid valve (Red to +, Black to -). Fig. 3b.  
12. Repeat Steps 3 through 11 for remaining Units in  
Multi Hook-up.  
M965274  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig 1  
MAINTENANCE  
DETECTION  
ONE  
Z
HANDWASHSENSOROPERATION;  
1
Fig. 1  
When the Sensor detects a user, the water  
immediately starts to flow. Water flow will stop Two  
seconds after user is out of sensor range. The off delay  
allows the user to comfortably move his hands without  
the flow cycling on to off. As a precaution, a safety  
timer will turn off the water, after the sensor has been  
blocked for 59 seconds. The water will stay off until the  
blockage is removed from the detection zone.  
Detection Zone: 2" - 10" (50mm - 250mm)  
Default: Set at Factory 6" (150mm)  
HOW TO CHANGE SENSOR  
2
Fig. 2  
RANGE; (Factory set at 6") Fig. 2  
1. Setting the Detection Zone (Distance):  
Remove cover from ENCLOSURE. Disconnect GRAY  
SENSOR WIRE (1) from circuit board, then reconnect.  
2. While the SENSOR CONTROL LED (2) is blinking  
slowly, place your hand 1 - 2 in. (30-50mm) in front of  
the sensor. Fig. 2a.  
1
3. When the LED stops blinking and stays "ON", move  
your hand to the desired position and hold in place until  
the LED begins to blink again. Fig. 2a.  
Fig. 2a  
1" - 2" (30mm - 50mm  
UP TO 10"  
(250mm)  
4. Once the SENSOR CONTROL LED (2) begins to  
blink again, remove your hand from the detection zone.  
When the flashing stops, the detection distance is set.  
2 BLINKING LED  
2 BLINKING LED  
HOW TO CLEAN AND REMOVE  
3
Fig.3  
THE AERATOR; Fig. 3  
1
3
1. Remove AERATOR HOUSING (1) with KEY supplied  
with faucet.  
3. Remove AERATOR (2) from HOUSING (1).  
2. Clean the AERATOR SCREENS (3) with a old tooth  
brush to remove dirt.  
4. Rinse Clean with water. Reassemble and install into  
spout end. Be sure black seal washer is in place.  
2
M965274  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOWTO CLEAN FILTER; Fig. 4  
4
Fig.4  
Before opening ENCLOSURE  
disconnect AC power supply.  
CAUTION  
1. Remove ENCLOSURE COVER.  
2. Close SUPPLY STOP (5) with 4mm Hex wrench.  
3
4
Note: Keep water flowing out of faucet while shutting off.  
3. Pull off Red (1) and Black (2) CONNECTORS from  
SOLENOID VALVE (3).  
CLEAN  
SCREENS  
4. Unthread STRAINER (4) using a 7/16" socket.  
5. Pull out the STRAINER (4) and clean with an old  
toothbrush. Rinse thoroughly with water.  
6. Install the STRAINER (4) back in its place and  
tighten with a 7/16" socket.  
2
5
4
1
Caution: do not over tighten strainer.  
Note: It is recommended to clean strainer every 6  
months.  
7. Replace ENCLOSURE COVER. Tighten cover  
screws firmly.  
GENERAL CLEANING; Fig. 5  
Fig.5  
5
1. For general cleaning use a damp, soft cloth to clean  
the spout and the sensor.  
2. For cleaning dirt use a soft cloth with diluted dish  
washing detergent. Wipe the area using a wet cloth  
and dry using a soft cloth.  
CAUTION  
Do not scratch the sensor when cleaning.  
Avoid using anything that may scratch the spout  
surface. Never use polishing power, detergent or a  
nylon scrub brush. They will damage the surface of the  
spout or Sensor.  
M965274  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
FAQ'S  
Q: How will I know if battery needs to be replaced?  
A: Valve does not open and sensor blinks 2 times  
interrupted by pause for up to 7 days.  
Q: Why does the faucet operate the opposite of  
expected-Turns On when not in sensor range, but turns  
off when in sensor range?  
A: Sensor wires to solenoid are reversed. Black to -  
& Red to + is correct.  
Q: Why has the flow rate of the faucet reduced  
significantly?  
A: Check and clean aerator and strainer.  
Q: What is the normal operating pressure range?  
A: Faucet will operate with supply pressures ranging  
from 20-80 psi.  
Q: There is no flow out of faucet when I'm in the  
sensor range?  
A: Check sensor. If sensor blinks 2 times interrupted by  
pause, replace battery, or call 1800-442-1902.  
M965274  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Telephone 900 0470 01 Rev AA User Manual
ACR Electronics Marine GPS System RLB 40 User Manual
Acroprint Switch DC7000 User Manual
Advantech Computer Hardware RMD 1150 User Manual
AEG Oven E4101 4 User Manual
Agilent Technologies TV Converter Box 1660A User Manual
Aiwa Stereo System CSD TD901 User Manual
Amana Dishwasher ADB1400AW User Manual
American Audio Music Mixer Q Spand Pro User Manual
Baldor Portable Generator AE10 User Manual