INSTALLATION INSTRUCTIONS  
For Two-Piece Toilets with Aquameter™ Fill Valve  
RENAISSANCE 2241  
COMPACT 2149.012, 3505  
COLONY 2388 / 2399 / 2359  
COLONY AFTON 2329.016  
Thank you for selecting American Standard - the benchmark of fine quality for over 100 years. To ensure this  
product is installed properly, please read these instructions carefully before you begin. (Certain installations may  
require professional help.) Also be sure your installation conforms to local codes  
!
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY  
HANDLE WITH CARE!  
NOTE: Pictures may not exactly define contour of china and components.  
RECOMMENDED TOOLS AND MATERIALS  
Putty Knife Regular Screwdriver  
Hacksaw Wax Ring/Gasket  
Adjustable Wrench  
Sealant  
Tape Measure  
Flexible Supply Tube Closet Bolts  
Carpenters Level  
1 REMOVE OLD TOILET  
a.  
b.  
c.  
d.  
Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.  
Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!  
Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.  
Remove closet bolts from flange and clean away old wax, putty, etc. from base area.  
NOTE: Mounting surface must be clean and level before new toilet is installed!  
2
3
ROUGHING-IN DIMENSIONS:  
NOTE: Distance from wall to closet flange centerline must  
be as listed below:  
For 4010.010/4310.016 Tanks: A = 254mm (10")  
For 4014/4314 Tanks: A = 356mm (14")  
CLOSET FLANGE  
For 4010.012/4392.016 and all other Tanks: A = 305mm (12")  
FINISHED WALL  
A
CLOSET BOLTS  
SUPPLY  
AS  
REQ'D.  
INSTALL CLOSET BOLTS  
°
Install closet bolts in flange channel, turn 90 ,  
and slide into place 6" (152 mm) apart and  
parallel to wall.  
FINISHED  
FLOOR  
A
Saniwares  
Product names listed herein are trademarks of American Standard Inc.  
American Standard Inc. 2004  
©
730237-100 REV. Q  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
TANK  
10  
FLOW RATE  
WATER INLET  
TO RAISE  
WATER  
LEVEL  
ADJUSTMENT  
LIFT  
ROD  
OVERFLOW  
TUBE  
REFILL  
TUBE  
WASHER  
+
TO LOWER  
-
FLEXIBLE  
SUPPLY  
WATER  
LEVEL  
COUPLING NUT  
FIG. 10A  
TRIP  
LEVER  
C
L
FLOAT  
BALL  
VALVE NUT  
WATER CONTROL  
ASSEMBLY  
COMPRESSION  
COLLAR  
WATER LINE  
LEVEL  
FLUSH  
VALVE  
FLOAT  
TRIM PLATE  
FLAPPER  
ASSEMBLY  
WATER INLET  
VALVE  
FLUSH VALVE  
CAUTION: Overtightening of  
COUPLING NUT could result in  
breakage and potential flooding.  
ADJUSTMENTS  
a. Flush tank and check that tank fills and shuts off within 30 to 60  
seconds, and tank water level is set as specified on tank rear wall.  
b. To adjust water level: turn water level adjustment screw  
counterclockwise to raise level; turn adjustment screw clockwise to  
lower level.  
c. To adjust flow rate (tank fill time): turn flow rate adjustment screw  
clockwise to decrease flow rate (increase fill time); turn adjustment  
screw counterclockwise to increase flow rate (decrease fill time).  
d. Carefully position tank cover on tank.  
e. The flush valve float has been factory set and does not require  
adjustments. Repositioning of the float will change the amount of  
water used which may effect the toilet's performance.  
f. If bowl fails to siphon, an adjustment may be required with the lift chain.  
Simply remove the bead chain from the retainment clip (see Fig. 10A)  
and take up slack on the chain, and reinsert on lift rod. Make sure the  
chain is not too taught.  
CONNECT WATER SUPPLY  
a. Connect water supply line between  
shutoff valve and tank water inlet  
fitting. Tighten COUPLING NUT 1/4 turn  
beyond hand tight. Check that refill tube  
is inserted into overflow tube.  
b. Turn on supply valve and allow tank to  
fill until float rises to shutoff position.  
c. Check for leakage at fittings, tighten or  
correct as needed.  
d. Do not use plumber's putty to seal  
these fittings.  
TANK NUMBER  
REPAIR PARTS LIST  
Repair parts are determined by toilet tank number which can be  
found marked inside tank.  
NOTE: "XXX" represents color or trim finish options. Specify  
when ordering.  
DESCRIPTION  
PART NO.  
047242-XXX0A  
047148-XXX0A  
047192-XXX0A  
738172-XXX0A  
738170-XXX0A  
738171-XXX0A  
034783-XXX0A  
738145-0070A  
738372-0070A  
738351-0070A  
738462-0070A  
738138-0070A  
738356-0070A  
047188-0070A  
047158-0070A  
738159-0070A  
738165-0070A  
TRIP LEVER  
TRIP LEVER  
TRIP LEVER  
RIGHT HAND TRIP LEVER  
RIGHT HAND TRIP LEVER  
RIGHT HAND TRIP LEVER  
BOLT CAP KIT (INCL 2 COVERS & WASHERS)  
WATER CONTROL ASS'y W FLOAT BALL  
WATER CONTROL ASS'y W FLOAT BALL  
WATER CONTROL ASS'y W FLOAT BALL  
WATER CONTROL ASS'y W FLOAT BALL  
FLUSH VALVE  
FLUSH VALVE  
COUPLING KIT, BOWL-TO-TANK  
COUPLING KIT, BOWL-TO-TANK  
FLAPPER ASSEMBLY  
FLAPPER ASSEMBLY  
CARE AND CLEANING  
11  
When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents,  
disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat. Some  
bathroom chemicals and cosmetics may damage the seat's finish.  
WARNING: Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the tank. This  
damage can cause leakage and property damage. American Standard shall not be responsible or liable for any tank fitting damage  
caused by the use of cleaners containing chlorine (calcium hypochlorite).  
!
- 3 -  
730237-100 REV. Q  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE  
PROBLEM  
Does not flush  
POSSIBLE CAUSE  
CORRECTIVE ACTION  
a. Water supply valve closed.  
b. Supply line blocked.  
a. Open valve and allow water to fill tank.  
b. Shut off water supply, disconnect supply line, and inspect  
all gaskets and washers. Reassemble.  
c. Flush valve chain too loose or  
disconnected.  
d. Stuck float/float rod.  
e. Water control flow rate too  
restricted.  
c. Readjust chain length as required.  
d. Adjust to allow free downward movement of float arm.  
e. Follow instructions to increase water control flow rate.  
Poor or  
sluggish flush  
a. Tank water level too low.  
b. Bowl water level too low.  
a. Follow instructions to adjust water level.  
b. Check that refill tube is connected to water control and  
inserted into tank overflow without being kinked or damaged.  
c. Open supply valve fully. Be sure that proper supply tube  
size is used.  
c. Supply valve partly closed.  
d. Flush valve closes early due to high  
supply pressure.  
d. Follow instructions to reduce water control flow rate.  
e. Partially clogged trapway and/or  
drain pipe and/or vent.  
e. Remove obstruction. Consult a plumber if necessary.  
f. Normal supply pressure must be at least 20 psi.  
f. Supply pressure too low.  
Toilet leaks  
a. Poor supply line connection.  
b. Poor bowl to tank/floor connection.  
a. Review Step 9 of installation procedure.  
b. Review Step 4 through 7 of installation procedure.  
Toilet does not  
shut off  
a. Tank water level too high.  
b. Float rod or float ball depressed by  
tank cover.  
a. Follow instructions to adjust water level.  
b. Readjust float rod.  
c. Flush valve chain too tight, holding  
flush valve open.  
c. Readjust chain length as needed.  
d. Float rod interfering with flush valve  
closing.  
d. Follow installation instructions to reduce water control flow  
rate, which will lift lowest position of float rod without  
affecting water level.  
e. Flush valve seat and/or flapper worn e. Replace flapper/flush valve assembly, as needed.  
or deformed.  
f. Sand or debris lodged in water  
control.  
f. Shut off water supply. Consult a plumber, if necessary.  
Noisy Flush  
a. Water control flow rate too restricted. a. Follow instructions to increase water control flow rate.  
AMERICAN-STANDARD ONE-YEAR LIMITED WARRANTY  
If inspection of this American-Standard plumbing product, within one year after its initial installation, confirms that it is defective in materials or  
workmanship, American-Standard will repair or, at its option, exchange the product for a similar model.  
This warranty does not apply to local building code compliance. Since local building codes vary considerably, the purchaser of this product should  
check with a local building or plumbing contractor to insure local code compliance before installation.  
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty maintenance, abuse,  
misuse, accident or other damage; if it was not installed in accordance with American-Standard's instructions; or if it has been modified in a manner  
inconsistent with the product as shipped by American-Standard.  
American-Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of removal or installation, nor  
shall American-Standard be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or  
exchange of a defective product, all of which are expressly excluded from this warranty. (Some states or provinces do not allow the exclusion or  
limitation of implied warranties, so this exclusion may not apply to you.)  
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province to province, in which case  
this warranty does not affect such statutory rights.  
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the product was purchased, or  
that a service request (including a description of the product model and of the defect) be sent to the following address:  
In Canada:  
In Mexico:  
In the United States:  
American Standard Inc.  
P.O. Box 6820  
Piscataway, New Jersey 08855  
Attention: Director of Consumer Affairs  
American Standard  
2480 Stanfield Rd.  
Mississauga, Ontario  
Canada L4Y 1S2  
Customer Service Manager  
Ideal Standard, S.A. de C.V.  
Via Morelos #330  
Col. Santa Clara  
Ecatepec 55540 Edo. Mexico  
Toll Free: (800) 387-0369  
For residents of the United States, warranty  
information may also be obtained by calling  
the following toll free number: (800) 442-1902  
730237-100 REV. Q  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

4XEM Home Security System IPCAMW40 User Manual
AEG Washer Dryer 1263 User Manual
Air King Ventilation Hood ARAGON SERIES User Manual
Alamo Lawn Mower SM72 User Manual
Alesis Music Mixer i02 User Manual
AllTrade Air Compressor 540010 User Manual
Alpine Car Stereo System CDE 9880R User Manual
Asus Cell Phone P525 User Manual
Audiovox Remote Starter APS 410a User Manual
Beckett Water Gardening Outdoor Fountain DP80 User Manual