		 INSTALLATION AND   
					OPERATION MANUAL   
					MODEL 2664   
					MODEL 2934   
					MODEL 2935   
					MODEL 2938   
					MODEL 2939   
					MODEL 2940   
					MODEL 2941   
					MODEL 2942   
					MODEL 2943   
					MODEL 2944   
					MODEL 2945   
					MODEL 3571   
					MODEL 3572   
					MODEL 2709   
					MODEL 2711   
					MODEL 2742   
					MODEL 2748   
					MODEL 2806   
					MODEL 2903   
					MODEL 2908   
					MODEL 2932   
					MODEL 2933   
					MODEL 3573   
					MODEL 3574   
					MODEL 3575   
					MODEL 3581   
					MODEL 3582   
					MODEL 3583   
					MODEL 3584   
					MODEL 6060   
					MODEL 7236   
					BATHTUBS, WHIRLPOOLS, AIR BATHS   
					AND COMBINATION TUBS WITH   
					OPTIONAL CHROMATHERAPY   
					THANK YOU...   
					for selecting an American Standard bath.Your new bath is shipped to you after careful inspection. The whirlpool   
					and air bath versions are completely assembled with pump/blower and system piping. All you need to finish the   
					installation are your selected fittings and electrical connections.   
					To ensure maximum performance and pleasure from this product, please follow the instructions and cautions.   
					For questions or service issues, please call Technical Support 1-(800)-442-1902.   
					Please do not contact or return product to the store.   
					© AS America, Inc. 2010   
					All product names listed herein are trademarks of AS America, Inc. unless otherwise noted.   
					754532-100 Rev. A   
					1 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				IMPORTANT SAFETY INSTRUCTIONS   
					READ AND FOLLOW ALL INSTRUCTIONS!   
					! 
					WARNING: Risk of personal injury. Do not permit children to use this bathtub without adult supervision. Never drop or   
					insert any object into any opening. Do not operate this unit without the guard over the suction fitting.   
					! 
					! 
					WARNING: Risk of electric shock. Do not permit electrical appliances near any bathtub when bathtub contains water.   
					WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse medical   
					history should consult a physician before using this product.   
					! 
					! 
					! 
					WARNING: Risk of personal injury. Do not overfill bathtub before entering. Entering tub when filled more than 2/3 can   
					cause overflow and slippery conditions. Exercise caution when entering and exiting.   
					WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not recommended. Avoid   
					alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia resulting in loss of   
					consciousness or even drowning.   
					WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.   
					Use this unit only for its intended use as described in this manual.   
					Do not use any attachments not recommended by American Standard.   
					The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter (GFCI). Such a   
					GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The   
					GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the   
					GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing,   
					indicating the possibility of an electric shock. Do not use this air bath. Disconnect the air bath and have the problem corrected by a   
					licensed electrician before using.   
					SAVE THESE INSTRUCTIONS   
					754532-100 Rev. A   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Installation and Framing Instructions   
					Each bath arrives ready for installation, completely equipped with the pump/blower electronics   
					and plumbing necessary for operation. However, a drain/overflow kit is required for each bath   
					and it is not included.   
					The variety of installations for this bath may require framing procedures other than those shown.   
					Locate studs as required. Ensure roughing-in dimensions are proper, plumb, and square.   
					! 
					Remove the bath from the carton. Retain the shipping carton until satisfactory   
					inspection of the product has been made. Do not lift the bath by the plumbing at   
					any time; handle by the shell only.   
					! 
					All bath units are factory tested for proper operation and watertight connections   
					prior to shipping. Prior to installation, the bath must be filled with water and   
					operated to check for leaks that may have resulted from shipping damage or   
					mishandling.   
					! 
					The sumps of these baths are supported by feet and no additional sump   
					support is required. Once the bath is in place, the feet should be shimmed and   
					secured accordingly so that the rim of the bath contacts the stringer or pier but   
					supports no weight.   
					Provisions must be made in all installations for an access opening for servicing the   
					bath pump/blower. Unless an access opening of at least 12" x 24" (305mm x 610mm)   
					is provided, warranty service will not be performed. It is strongly recommended that an   
					additional opening be provided for access to drain components.   
					! 
					! 
					Each bath has a nominal length (L), width (W), and Height (H) along with a rim   
					height. Unless otherwise noted in the following rough-in references, assume   
					that the nominal tolerances are as much as +/-1/4 inch (6mm). Therefore, it is   
					strongly recommended that the installer build the surrounding structure after   
					receiving the actual bath. Structural measurements should be verified against   
					the actual bath received to ensure proper fit.   
					POST INSTALLATION CLEAN-UP   
					Remove all construction debris from bath. Tile grout can be removed with a wooden   
					popsicle stick or tongue depressor.   
					Do not use wire brushes or any other metal implement on bath surface.   
					Post installation clean-up generally can be completed using warm water and liquid   
					dishwashing detergent.   
					Stubborn dirt or stains may be removed using granular Spic and Span® mixed with water.   
					Painter's naphtha can be used to remove excess adhesives and/or wet oil-base paint.   
					754532-100 Rev. A   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES FOR RECESS TYPE INSTALLATIONS   
					C 
					12"   
					(305 mm)   
					E 
					LEVELING   
					NOTE:   
					STRINGERS   
					24"   
					FRONT EDGE   
					(610 mm)   
					OF BATH MUST   
					BE SUPPORTED   
					BY STUD WALL OR   
					ACCESS PANEL MUST BE LOCATED   
					AMERICAN STANDARD   
					ON THE SAME SIDE AS THE MOTOR.   
					APRON KIT   
					ALLOW OPEN FRAMING ON   
					PUMP/MOTOR END FOR SERVICE.   
					ACCESS PANELS NOT   
					REQUIRED FOR BATH TUBS   
					UNLESS AN ACCESS OPENING OF AT LEAST 12" x 24" (305 x 610mm)   
					IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.   
					TYPICAL TILE BEAD INSTALLATION   
					TYPICAL TILE FLANGE INSTALLATION   
					WOOD   
					STUDS   
					STUD   
					WATERPROOF DRYWALL   
					OR CEMENT BOARD   
					TILE   
					TILE   
					ROOFING NAIL   
					SEALANT   
					WALLBOARD   
					SEALANT   
					TUB   
					TILE   
					BEAD   
					STRIP   
					BATH   
					1" x 3" (25 x 76mm) WOOD   
					STRINGER FULL LENGTH   
					ADHESIVE   
					STEEL   
					STUDS   
					STEEL   
					STUD   
					WASHER   
					WATERPROOF DRYWALL   
					OR CEMENT BOARD   
					TILE   
					LEVELING STRINGER   
					1" x 4" (25mm x 102mm) not for support   
					SEALANT   
					4" (102mm)   
					DRYWALL   
					SCREW   
					NOTE: Tile bead kit not included and must   
					TUB   
					be purchased separately.   
					1" x 3" (25 x 76mm) WOOD   
					STRINGER FULL LENGTH   
					SECURE THE BATH TO THE STUDS AS SHOWN   
					FOR WOOD OR STEEL STUD CONSTRUCTION.   
					754532-100 Rev. A   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES FOR PIER TYPE INSTALLATIONS   
					AS DESIRED   
					F 
					CUTOUT   
					G 
					CUTOUT   
					C 
					12"   
					(305 mm)   
					AS DESIRED   
					MOUNTING   
					SURFACE   
					WATERPROOF   
					SEALANT   
					24"   
					(610 mm)   
					ACCESS PANEL MUST BE LOCATED   
					ON THE SAME SIDE AS THE MOTOR.   
					BATH   
					ALLOW OPEN FRAMING ON   
					PUMP/MOTOR END FOR SERVICE.   
					ACCESS PANELS NOT REQUIRED   
					FOR BATH TUBS   
					UNLESS AN ACCESS OPENING OF AT LEAST 12" X 24" (305 X 610mm)   
					IS PROVIDED, WARRANTY SERVICE WILL NOT BE PERFORMED.   
					UNDER DECK MOUNTING INSTRUCTIONS   
					Please note that care must be taken to protect the surface of the tub during all aspects of the installation.   
					Do not drill or cut the bath deck with the tub directly beneath it as damage to the tub may result.   
					1. Install the tub per the installation instructions provided with the unit.   
					2. Prepare the bath deck support structure per the local codes. Note - the bath deck must be self supporting.   
					3. Cut bath deck to your specifications.   
					4. Place the bath deck in position and trace the opening on the tub with a soft pencil. Do not drill or cut the bath   
					deck with the tub directly beneath it as damage to the tub may result.   
					5. Remove the bath deck and apply a generous bead of waterproof sealant on the outer edge of the traced line.   
					6. Replace the bath deck and secure it into place.   
					7. Apply additional sealant along the tub and bath deck interface as necessary to ensure a watertight seal.   
					8. Remove excess sealant per the manufacturer's instructions.   
					Finished bath deck surface material must be   
					self-supporting and secured per local codes   
					Waterproof   
					Bath deck support material   
					Sealant   
					Bathtub   
					Tub support structure per installation   
					instructions provided with the tub   
					754532-100 Rev. A   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR WHIRLPOOLS AND BATH TUBS   
					Description   
					Dimensions   
					L-W-H   
					Drain /   
					Height to   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Overflow Underside   
					of Deck: C   
					Weight   
					Overflow Operating   
					Volume   
					2664   
					Scala   
					Corner   
					L 83-1/2" (2121mm)   
					W 63-3/4" (1619mm)   
					H 19-3/4" (502mm)   
					A 16"   
					C 18-1/4"   
					(406mm) (464mm)   
					B 13-1/4"   
					Template   
					Provided   
					N/A   
					6-3/8"   
					(162mm)   
					781 lb. (351 kg)/   
					37 lb./sq.ft.   
					(182 kg/sq.m)   
					94 lb.   
					(43 kg.)   
					80 gal.   
					(303 l.)   
					58 gal.   
					(220 l.)   
					(337mm)   
					2709   
					L 
					69-1/4" (1759mm)   
					A 15"   
					C 18-1/4"   
					(381mm) (464mm)   
					B 9-7/8"   
					Template   
					Provided   
					As   
					Desired   
					3"   
					(76mm)   
					640 lb. (291 kg)/ 107 lb.   
					64 gal.   
					(242 l.)   
					53 gal.   
					(200 l.)   
					Ellisse Oval W 38-1/2" (978mm)   
					35 lb./sq.ft.   
					(49 kg.)   
					6'   
					H 19-3/4" (502mm)   
					(171 kg/sq.m)   
					(251mm)   
					2711   
					Ellisse   
					6' x 48"   
					L 
					72" (1829mm)   
					A 16-5/8" C 19-1/2"   
					(422mm) (495mm)   
					B 12"   
					70-1/2"   
					72-3/16"   
					4"   
					950 lb. (431 kg)/ 133 lb.   
					95 gal.   
					(359 l.)   
					74 gal.   
					(280 l.)   
					W 48" (1219mm)   
					H 21-1/2" (546mm)   
					40 lb./sq.ft.   
					(60 kg.)   
					(1791mm)   
					x 46-1/2"   
					(1181mm)   
					(1833mm)   
					x 46-1/2"   
					(1181mm)   
					(102mm)   
					(196 kg/sq.m)   
					(305mm)   
					2742   
					Town Square   
					6' x 42"   
					A 16-1/4" C 20"   
					(413mm) (508mm)   
					B 13-1/4"   
					70"   
					71-11/16"   
					(1821mm)   
					x 40-1/4"   
					(1022mm)   
					4"   
					690 lb. (313 kg)/ 115 lb.   
					69 gal.   
					60 gal.   
					(227 l.)   
					L 
					71-1/2" (1816mm)   
					(1778mm)   
					x 40-1/4"   
					(1022mm)   
					(102mm)   
					33 lb./sq.ft.   
					(52 kg.) (261 l.)   
					W 41-3/4" (1060mm)   
					H 22" (559mm)   
					(161 kg/sq.m)   
					(337mm)   
					2748   
					Town Square   
					5' x 42"   
					A 14-1/2" C 21"   
					(368mm) (533mm)   
					B 14-1/2"   
					58"   
					59-11/16"   
					(1517mm)   
					x 40-1/8"   
					(1019mm)   
					5-1/4"   
					(133mm)   
					611 lb. (277 kg)/ 110 lb.   
					60 gal.   
					55 gal.   
					(208 l.)   
					L 
					59-1/2" (1511mm)   
					(1473mm)   
					x 40-1/8"   
					(1019mm)   
					40 lb./sq.ft.   
					(50 kg.) (227 l.)   
					W 41-5/8" (1057mm)   
					H 23" (584mm)   
					(196 kg/sq.m)   
					(368mm)   
					2806   
					Heritage Oval   
					6' x 36"   
					L 
					72" (1829mm)   
					A 17"   
					C 19-1/2"   
					(432mm) (495mm)   
					B 11"   
					Template   
					Provided   
					As   
					Desired   
					5-1/2"   
					(140mm)   
					744 lb. (338 kg)/ 135 lb.   
					73 gal.   
					44 gal.   
					(166 l.)   
					41 lb./sq.ft.   
					(61 kg.) (276 l.)   
					W 35-3/4" (908mm)   
					H 21-1/2" (546mm)   
					(200 kg/sq.m)   
					(279mm)   
					2903   
					Savona Oval   
					5' x 42"   
					L 
					60" (1524mm)   
					W 42-1/4" (1073mm) (432mm) (489mm)   
					A 17"   
					C 19-1/4"   
					Template   
					Provided   
					3"   
					(76mm)   
					640 lb. (291 kg)/ 107 lb.   
					64 gal.   
					53 gal.   
					(200 l.)   
					As   
					Desired   
					35 lb./sq.ft.   
					(171 kg/sq.m)   
					(49 kg.) (242 l.)   
					H 21-1/4" (540mm)   
					B 9-1/2"   
					(241mm)   
					As   
					Desired   
					95 lb.   
					(43 kg.)   
					2908   
					Reminiscence   
					Oval   
					L 
					66" (1676mm)   
					A 17"   
					(432mm)   
					B 13"   
					C 18-1/4"   
					(464mm)   
					Template   
					Provided   
					6"   
					659 lb. (299 kg)/   
					40 lb./sq.ft.   
					(191 kg/sq.m)   
					68 gal.   
					(257 l.)   
					55 gal.   
					(208 l.)   
					W 36" (914mm)   
					H 24-1/4" (616mm)   
					(152mm)   
					(330mm)   
					108 lb.   
					(49 kg.)   
					5-5/8"   
					(130mm)   
					824 lb. (374 kg)/   
					25 lb./sq.ft.   
					(117 kg/sq.m)   
					86 gal.   
					(352 l.)   
					71 gal.   
					(269 l.)   
					N/A   
					6060   
					Cadenza   
					Corner   
					L 
					76-3/4" (1949mm)   
					A 17"   
					C 19-1/2"   
					(495mm)   
					Template   
					Provided   
					751680-100   
					W 65-3/8" (1661mm)   
					H 21-1/2" (546mm)   
					(432mm)   
					B 13-3/4"   
					(349mm)   
					101 lb.   
					(45 kg.)   
					7236   
					Virtuoso   
					6' x 36"   
					L 
					72" (1829mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					C 19-1/4"   
					(489mm)   
					70-1/2"   
					72-3/16"   
					(1833mm)   
					x 34-1/2"   
					(876mm)   
					4"   
					751 lb. (338 kg)/   
					42 lb./sq.ft.   
					(204 kg/sq.m)   
					78 gal.   
					(296 l.)   
					69 gal.   
					(262 l.)   
					W 36" (914mm)   
					H 21-1/4" (540mm)   
					(1791mm)   
					x 34-1/2"   
					(876mm)   
					(102mm)   
					(279mm)   
					TABLE 1   
					754532-100 Rev. A   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 2664   
					1" (25mm)   
					INTEGRAL TILE   
					FLANGE (2) SIDES   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					10" x 10"   
					(254mm x 254mm)   
					DRAIN OUTLET   
					CUTOUT   
					21-3/4"   
					(552mm)   
					8-1/2"   
					(216mm)   
					3/4"(19mm)   
					CUTOUT DIMENSION   
					16"   
					(406mm)   
					C 
					L 
					OF DRAIN OUTLET   
					41"   
					(1041mm)   
					MODEL SERIES 2709   
					69-1/4"   
					(1759mm)   
					9-7/16"   
					(240mm)   
					OUTLINE OF   
					CUTOUT   
					12" (305mm) x 9" (229mm)   
					CUTOUT IN FLOOR FOR DRAIN   
					38-1/2"   
					(978mm)   
					19-1/4"   
					(489mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					3"   
					(76mm)   
					COF DRAIN   
					L 
					OUTLET   
					754532-100 Rev. A   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 2711   
					72"   
					(1829mm)   
					OUTLINE OF CUTOUT   
					4"   
					36-1/2"   
					(927mm)   
					70-1/2" X 46-1/2"   
					(1791 X 1181mm)   
					(102mm)   
					12"   
					(305mm)   
					C/L OF   
					DRAIN   
					9" x 14"   
					(229 x 356mm)   
					FLOOR   
					CUTOUT   
					48"   
					(1219mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					GRAB BAR   
					FITTING AREA   
					OPTIONAL   
					DECK FITTING   
					AREA   
					RECOMMENDED   
					FITTING   
					LOCATION   
					2-1/2" X 11"   
					MODEL SERIES 2908   
					66"   
					(1676mm)   
					13"   
					(330mm)   
					18"   
					(457mm)   
					9" X 12"   
					(229 x 305mm)   
					FLOOR   
					CUTOUT   
					36"   
					(914mm)   
					2-1/2" REF.   
					(64mm)   
					INTEGRAL   
					FITTING   
					DECK   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					6"   
					OVERFLOW   
					OUTLINE OF   
					CUTOUT   
					(152mm)   
					C/L OF   
					DRAIN   
					OUTLET   
					754532-100 Rev. A   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 2806   
					72"   
					(1829mm)   
					11"   
					(279mm)   
					18"   
					(457mm)   
					9" x 13"   
					(229 x 330mm)   
					FLOOR CUTOUT   
					35-3/4"   
					(908mm)   
					INTEGRAL   
					FITTING   
					DECK   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					5-1/2"   
					(140mm)   
					C/L OF DRAIN   
					OVERFLOW   
					OUTLINE   
					OF CUTOUT   
					MODEL SERIES 2903   
					60"   
					(1524mm)   
					9-1/2"   
					(241mm)   
					OUTLINE OF   
					CUTOUT - USE   
					TEMPLATE   
					4-1/4"   
					(1073mm)   
					12" (305mm) X 9"(229mm)   
					CUTOUT IN FLOOR FOR DRAIN   
					21-1/8"   
					(537mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					3"   
					(76mm)   
					C 
					OF DRAIN   
					OUTLET   
					L 
					754532-100 Rev. A   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 2742   
					71-1/2"   
					(1816mm)   
					4"   
					(102mm)   
					INTEGRAL   
					35-3/4"   
					FITTING DECK   
					3" x 14"   
					(76 x 356mm)   
					3"   
					(76mm)   
					(908mm)   
					13-1/4"   
					(337mm)   
					C/L OF DRAIN OUTLET   
					EDGE   
					OF FLOOR   
					CUTOUT   
					41-3/4"   
					(1060mm)   
					FLOOR CUTOUT   
					5" X 15"   
					(127 X 381mm)   
					26-3/4"   
					(679mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					3/4"   
					(19mm)   
					ALL INSTALLATIONS   
					OUTLINE OF CUTOUT   
					70" X 40-1/4"   
					(1778 X 1022mm)   
					MODEL SERIES 2748   
					59-1/2"   
					(1511mm)   
					INTEGRAL   
					FITTING DECK   
					3" X 14"   
					3"   
					(76mm)   
					29-7/8"   
					(759mm)   
					5-1/4"   
					(133mm)   
					(76 X 356mm)   
					14-1/2"   
					(368mm)   
					C/L OF   
					DRAIN   
					OUTLET   
					FLOOR CUTOUT   
					5" X 12"   
					(127 X 305mm)   
					EDGE OF   
					FLOOR   
					CUTOUT   
					41-5/8"   
					(1057mm)   
					3/4"   
					(19mm)   
					OUTLINE OF CUTOUT   
					58-1/4" X 40-1/4"   
					(1480 X 1022mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					754532-100 Rev. A   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 6060   
					76-3/4" REF.   
					(1949mm)   
					38-3/8"   
					(975mm)   
					C/L   
					OUTLINE OF   
					CUTOUT   
					SEAT AREA   
					65-3/8"   
					(1661mm)   
					7" x 15" CUTOUT   
					(178mm x 381mm)   
					PROVIDE ACCESS TO PUMP   
					FOR SERVICE ON ALL INSTALLATIONS   
					NOTE: APRON ASSEMBLY WILL   
					PROVIDE REQUIRED   
					ACCESS FOR SERVICING   
					13-5/8"   
					(346mm)   
					C/L OF   
					DRAIN   
					5-5/8"   
					(143mm)   
					RECOMMENDED FITTING LOCATION   
					2-1/2" x 15" (64 x 381mm)   
					10"   
					(254mm)   
					4-1/2"   
					(114mm)   
					USE CUTOUT TEMPLATE SUPPLIED WITH PACKAGED PRODUCT.   
					MODEL SERIES 7236   
					72"   
					(1829mm)   
					36"   
					(914mm)   
					3/4"   
					(19mm)   
					TYP.   
					OUTLINE OF CUTOUT   
					70-1/2" x 34-1/2"   
					(1791mm X 876mm)   
					36"   
					(914mm)   
					7 x 14 CUTOUT   
					(178 x 356mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					C/L OF DRAIN   
					4"   
					18-1/2"   
					(470mm)   
					(102mm)   
					11"   
					(279mm)   
					RECOMMENDED   
					FITTING LOCATION   
					2-1/2" x 11" (64 x 279mm)   
					754532-100 Rev. A   
					12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR STUDIO 5' X 32" WHIRLPOOLS AND BATH TUBS   
					Description   
					Deck   
					Trim   
					Option   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Weight   
					Overflow Operating   
					Volume   
					A 17-3/4"   
					(451mm)   
					B 10-3/4"   
					(273mm)   
					C 21-7/8"   
					(556mm)   
					58"   
					(1473mm)   
					x 30"   
					59-11/16"   
					(1516mm)   
					x 30"   
					581 lb. (264 kg)/   
					44 lb./sq.ft.   
					(213 kg/sq.m)   
					90 lb.   
					(198 kg.)   
					59 gal.   
					(224 l.)   
					54 gal.   
					(205 l.)   
					2932   
					Studio   
					5' x 32"   
					Zero   
					(5/8")   
					L 59-1/2" (1511mm)   
					W 31-1/2" (800mm)   
					H 22-1/2" (572mm)   
					(762mm)   
					(762mm)   
					A 17-3/4"   
					(451mm)   
					B 10-7/8"   
					(276mm)   
					C 20-1/2"   
					(521mm)   
					58-1/4"   
					59-15/16"   
					(1522mm)   
					x 30-1/4"   
					(768mm)   
					581 lb. (264 kg)/   
					44 lb./sq.ft.   
					(213 kg/sq.m)   
					90 lb.   
					(198 kg.)   
					59 gal.   
					(224 l.)   
					54 gal.   
					(205 l.)   
					2932   
					Studio   
					5' x 32"   
					2"   
					L 59-3/4" (1518mm)   
					W 31-3/4" (806mm)   
					H 22-1/2" (572mm)   
					(1480mm)   
					x 30-1/4"   
					(768mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					18-1/2"   
					(470mm)   
					58-1/2"   
					60-3/16"   
					(1529mm)   
					x 30-1/2"   
					(775mm)   
					581 lb. (264 kg)/   
					44 lb./sq.ft.   
					(213 kg/sq.m)   
					90 lb.   
					(198 kg.)   
					59 gal.   
					(224 l.)   
					54 gal.   
					(205 l.)   
					2932   
					Studio   
					5' x 32"   
					4"   
					L 60" (1524mm)   
					W 32" (813mm)   
					H 22-1/2" (572mm)   
					(1486mm)   
					x 30-1/2"   
					(775mm)   
					(279mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					C 20-1/2"   
					(521mm)   
					N/A   
					60-3/16"   
					(1529mm)   
					x 30-3/8"   
					(772mm)   
					581 lb. (264 kg)/   
					44 lb./sq.ft.   
					(213 kg/sq.m)   
					90 lb.   
					(198 kg.)   
					59 gal.   
					(224 l.)   
					54 gal.   
					(205 l.)   
					2933   
					Studio   
					5' x 32"   
					N/A   
					L 60" (1524mm)   
					W 31-7/8" (810mm)   
					H 22-1/2" (572mm)   
					(279mm)   
					w/Tile Flange   
					TABLE 2   
					ROUGH-IN REFERENCES   
					MODEL SERIES 2932 & 2933   
					60" NOMINAL   
					(1524mm)   
					OVERFLOW   
					C/L DRAIN   
					32" NOMINAL   
					(813mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					9" x 15"   
					(229 x 305mm)   
					DRAIN ASS’Y   
					ALL INSTALLATIONS   
					FLOOR CUTOUT   
					OUTLINE OF   
					CUTOUT   
					754532-100 Rev. A   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR STUDIO 5' X 36" WHIRLPOOLS AND BATH TUBS   
					Description   
					Deck   
					Trim   
					Option   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Weight   
					Overflow Operating   
					Volume   
					A 17-3/4"   
					(451mm)   
					B 10-3/4"   
					(273mm)   
					C 21-7/8"   
					(556mm)   
					58"   
					(1473mm)   
					x 34"   
					59-11/16"   
					(1516mm)   
					x 34"   
					686 lb. (311 kg)/   
					46 lb./sq.ft.   
					(223 kg/sq.m)   
					95 lb.   
					(209 kg.)   
					71 gal.   
					(269 l.)   
					64 gal.   
					(243 l.)   
					2934   
					Studio   
					5' x 36"   
					Zero   
					(5/8")   
					L 59-1/2" (1511mm)   
					W 35-1/2" (902mm)   
					H 22-1/2" (572mm)   
					(864mm)   
					(864mm)   
					A 17-3/4"   
					(451mm)   
					B 10-7/8"   
					(276mm)   
					C 20-1/2"   
					(521mm)   
					58-1/4"   
					59-15/16"   
					(1522mm)   
					x 34-1/4"   
					(870mm)   
					686 lb. (311 kg)/   
					46 lb./sq.ft.   
					(223 kg/sq.m)   
					95 lb.   
					(209 kg.)   
					71 gal.   
					(269 l.)   
					64 gal.   
					(243 l.)   
					2934   
					Studio   
					5' x 36"   
					2"   
					L 59-3/4" (1518mm)   
					W 35-3/4" (908mm)   
					H 22-1/2" (572mm)   
					(1480mm)   
					x 34-1/4"   
					(870mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					18-1/2"   
					(470mm)   
					58-1/2"   
					60-3/16"   
					(1529mm)   
					x 34-1/2"   
					(876mm)   
					686 lb. (311 kg)/   
					46 lb./sq.ft.   
					(223 kg/sq.m)   
					95 lb.   
					(209 kg.)   
					71 gal.   
					(269 l.)   
					64 gal.   
					(243 l.)   
					2934   
					Studio   
					5' x 36"   
					4"   
					L 60" (1524mm)   
					W 36" (914mm)   
					H 22-1/2" (572mm)   
					(1486mm)   
					x 34-1/2"   
					(876mm)   
					(279mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					C 20-1/2"   
					(521mm)   
					N/A   
					60-3/16"   
					(1529mm)   
					x 34-3/8"   
					(873mm)   
					686 lb. (311 kg)/   
					46 lb./sq.ft.   
					(223 kg/sq.m)   
					95 lb.   
					(209 kg.)   
					71 gal.   
					(269 l.)   
					64 gal.   
					(243 l.)   
					2935   
					Studio   
					5' x 36"   
					N/A   
					L 60" (1524mm)   
					W 35-7/8" (911mm)   
					H 22-1/2" (572mm)   
					(279mm)   
					w/Tile Flange   
					TABLE 3   
					ROUGH-IN REFERENCES   
					MODEL SERIES 2934 & 2935   
					60" NOMINAL   
					(1524mm)   
					OVERFLOW   
					C/L DRAIN   
					36" NOMINAL   
					(914mm)   
					9" x 15"   
					(229 x 305mm)   
					DRAIN ASS’Y   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					FLOOR CUTOUT   
					ALL INSTALLATIONS   
					OUTLINE OF   
					CUTOUT   
					754532-100 Rev. A   
					14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR STUDIO 5-1/2' X 36" WHIRLPOOLS AND BATH TUBS   
					Description   
					Deck   
					Trim   
					Option   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Weight   
					Overflow Operating   
					Volume   
					A 17-3/4"   
					(451mm)   
					B 10-3/4"   
					(273mm)   
					C 21-7/8"   
					(556mm)   
					64"   
					(1626mm)   
					x 34"   
					65-11/16"   
					(1668mm)   
					x 34"   
					766 lb. (348 kg)/   
					46 lb./sq.ft.   
					(227 kg/sq.m)   
					100 lb.   
					(220 kg.)   
					80 gal.   
					(303 l.)   
					73 gal.   
					(277 l.)   
					2938   
					Studio   
					5-1/2' x 36"   
					Zero   
					(5/8")   
					L 65-1/2" (1664mm)   
					W 35-1/2" (902mm)   
					H 22-1/2" (572mm)   
					(864mm)   
					(864mm)   
					A 17-3/4"   
					(451mm)   
					B 10-7/8"   
					(276mm)   
					C 20-1/2"   
					(521mm)   
					64-1/4"   
					65-15/16"   
					(1675mm)   
					x 34-1/4"   
					(870mm)   
					766 lb. (348 kg)/   
					46 lb./sq.ft.   
					(227 kg/sq.m)   
					100 lb.   
					(220 kg.)   
					80 gal.   
					(303 l.)   
					73 gal.   
					(277 l.)   
					2938   
					Studio   
					5-1/2' x 36"   
					2"   
					L 65-3/4" (1670mm)   
					W 35-3/4" (908mm)   
					H 22-1/2" (572mm)   
					(1632mm)   
					x 34-1/4"   
					(870mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					18-1/2"   
					(470mm)   
					64-1/2"   
					66-3/16"   
					(1681mm)   
					x 34-1/2"   
					(876mm)   
					766 lb. (348 kg)/   
					46 lb./sq.ft.   
					(227 kg/sq.m)   
					100 lb.   
					(220 kg.)   
					80 gal.   
					(303 l.)   
					73 gal.   
					(277 l.)   
					2938   
					Studio   
					5-1/2' x 36"   
					4"   
					L 66" (1676mm)   
					W 36" (914mm)   
					H 22-1/2" (572mm)   
					(1638mm)   
					x 34-1/2"   
					(876mm)   
					(279mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					C 20-1/2"   
					(521mm)   
					N/A   
					66-3/16"   
					(1681mm)   
					x 34-3/8"   
					(873mm)   
					766 lb. (348 kg)/   
					46 lb./sq.ft.   
					(227 kg/sq.m)   
					100 lb.   
					(220 kg.)   
					80 gal.   
					(303 l.)   
					73 gal.   
					(277 l.)   
					2939   
					Studio   
					5-1/2' x 36"   
					w/Tile Flange   
					N/A   
					L 66" (1676mm)   
					W 35-7/8" (911mm)   
					H 22-1/2" (572mm)   
					(279mm)   
					TABLE 4   
					ROUGH-IN REFERENCES   
					MODEL SERIES 2938 & 2939   
					66" NOMINAL   
					(1524mm)   
					OVERFLOW   
					C/L DRAIN   
					36" NOMINAL   
					(914mm)   
					9" x 15"   
					(229 x 305mm)   
					DRAIN ASS’Y   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					FLOOR CUTOUT   
					ALL INSTALLATIONS   
					OUTLINE OF   
					CUTOUT   
					754532-100 Rev. A   
					15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR STUDIO 6' X 36" WHIRLPOOLS AND BATH TUBS   
					Description   
					Deck   
					Trim   
					Option   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Weight   
					Overflow Operating   
					Volume   
					A 17-3/4"   
					(451mm)   
					B 10-3/4"   
					(273mm)   
					C 21-7/8"   
					(556mm)   
					70"   
					(1778mm)   
					x 34"   
					71-11/16"   
					(1821mm)   
					x 34"   
					846 lb. (384 kg)/   
					47 lb./sq.ft.   
					(230 kg/sq.m)   
					105 lb.   
					(231 kg.)   
					89 gal.   
					(337 l.)   
					81 gal.   
					(307 l.)   
					2940   
					Studio   
					6' x 36"   
					Zero   
					(5/8")   
					L 71-1/2" (1816mm)   
					W 35-1/2" (902mm)   
					H 22-1/2" (572mm)   
					(864mm)   
					(864mm)   
					A 17-3/4"   
					(451mm)   
					B 10-7/8"   
					(276mm)   
					C 20-1/2"   
					(521mm)   
					70-1/4"   
					71-15/16"   
					(1827mm)   
					x 34-1/4"   
					(870mm)   
					846 lb. (384 kg)/   
					47 lb./sq.ft.   
					(230 kg/sq.m)   
					105 lb.   
					(231 kg.)   
					89 gal.   
					(337 l.)   
					81 gal.   
					(307 l.)   
					2940   
					Studio   
					6' x 36"   
					2"   
					L 71-3/4" (1822mm)   
					W 35-3/4" (908mm)   
					H 22-1/2" (572mm)   
					(1784mm)   
					x 34-1/4"   
					(870mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					18-1/2"   
					(470mm)   
					70-1/2"   
					72-3/16"   
					(1833mm)   
					x 34-1/2"   
					(876mm)   
					846 lb. (384 kg)/   
					47 lb./sq.ft.   
					(230 kg/sq.m)   
					105 lb.   
					(231 kg.)   
					89 gal.   
					(337 l.)   
					81 gal.   
					(307 l.)   
					2940   
					Studio   
					6' x 36"   
					4"   
					L 72" (1829mm)   
					W 36" (914mm)   
					H 22-1/2" (572mm)   
					(1791mm)   
					x 34-1/2"   
					(876mm)   
					(279mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					C 20-1/2"   
					(521mm)   
					N/A   
					72-3/16"   
					(1833mm)   
					x 34-3/8"   
					(873mm)   
					846 lb. (384 kg)/   
					47 lb./sq.ft.   
					(230 kg/sq.m)   
					105 lb.   
					(231 kg.)   
					89 gal.   
					(337 l.)   
					81 gal.   
					(307 l.)   
					2941   
					Studio   
					6' x 36"   
					N/A   
					L 72" (1829mm)   
					W 35-7/8" (911mm)   
					H 22-1/2" (572mm)   
					(279mm)   
					w/Tile Flange   
					TABLE 5   
					ROUGH-IN REFERENCES   
					MODEL SERIES 2940 & 2941   
					72" NOMINAL   
					(1524mm)   
					OVERFLOW   
					C/L DRAIN   
					36" NOMINAL   
					(813mm)   
					9" x 15"   
					(229 x 305mm)   
					DRAIN ASS’Y   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					FLOOR CUTOUT   
					ALL INSTALLATIONS   
					OUTLINE OF   
					CUTOUT   
					754532-100 Rev. A   
					16   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR STUDIO 6' X 42" WHIRLPOOLS AND BATH TUBS   
					Description   
					Deck   
					Trim   
					Option   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Weight   
					Overflow Operating   
					Volume   
					A 17-3/4"   
					(451mm)   
					B 10-3/4"   
					(273mm)   
					C 21-7/8"   
					(556mm)   
					70"   
					(1778mm)   
					x 40"   
					943 lb. (428 kg)/   
					45 lb./sq.ft.   
					(219 kg/sq.m)   
					110 lb.   
					(242 kg.)   
					100 gal. 91 gal.   
					L 71-1/2" (1816mm)   
					W 41-1/2" (1054mm)   
					H 22-1/2" (572mm)   
					71-11/16"   
					(1821mm)   
					x 40"   
					2942   
					Studio   
					6' x 42"   
					Zero   
					(5/8")   
					(379 l.)   
					(345 l.)   
					(1016mm)   
					(1016mm)   
					A 17-3/4"   
					(451mm)   
					B 10-7/8"   
					(276mm)   
					C 20-1/2"   
					(521mm)   
					70-1/4"   
					71-15/16"   
					(1827mm)   
					x 40-1/4"   
					(1022mm)   
					943 lb. (428 kg)/   
					45 lb./sq.ft.   
					(219 kg/sq.m)   
					110 lb.   
					(242 kg.)   
					100 gal. 91 gal.   
					(379 l.) (345 l.)   
					2942   
					Studio   
					6' x 42"   
					2"   
					L 71-3/4" (1822mm)   
					W 41-3/4" (1060mm)   
					H 22-1/2" (572mm)   
					(1784mm)   
					x 40-1/4"   
					(1022mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					18-1/2"   
					(470mm)   
					70-1/2"   
					72-3/16"   
					943 lb. (428 kg)/   
					45 lb./sq.ft.   
					(219 kg/sq.m)   
					110 lb.   
					(242 kg.)   
					100 gal. 91 gal.   
					(379 l.) (345 l.)   
					2942   
					Studio   
					6' x 42"   
					4"   
					L 72" (1829mm)   
					W 42" (1067mm)   
					H 22-1/2" (572mm)   
					(1791mm)   
					x 40-1/2"   
					(1029mm)   
					(1833mm)   
					x 40-1/2"   
					(1029mm)   
					(279mm)   
					A 17-3/4"   
					(451mm)   
					B 11"   
					C 20-1/2"   
					(521mm)   
					N/A   
					72-3/16"   
					943 lb. (428 kg)/   
					45 lb./sq.ft.   
					(219 kg/sq.m)   
					110 lb.   
					(242 kg.)   
					100 gal. 91 gal.   
					(379 l.) (345 l.)   
					2943   
					Studio   
					6' x 42"   
					N/A   
					L 72" (1829mm)   
					W 41-7/8" (1063mm)   
					H 22-1/2" (572mm)   
					(1833mm)   
					x 40-3/8"   
					(1026mm)   
					(279mm)   
					w/Tile Flange   
					TABLE 6   
					ROUGH-IN REFERENCES   
					MODEL SERIES 2942 & 2943   
					C/L DRAIN   
					9" x 15" (229 x 305mm)   
					DRAIN ASS’Y FLOOR CUTOUT   
					OVERFLOW   
					36" NOMINAL   
					(813mm)   
					OUTLINE OF   
					CUTOUT   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					72" NOMINAL   
					(1524mm)   
					754532-100 Rev. A   
					17   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR STUDIO CORNER WHIRLPOOLS AND BATH TUBS   
					Description   
					Deck   
					Trim   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Weight   
					Overflow Operating   
					Volume   
					988 lb. (448 kg)/   
					27 lb./sq.ft.   
					(133 kg/sq.m)   
					130 lb.   
					(59 kg.)   
					103 gal.   
					(390 l.)   
					65 gal.   
					(246 l.)   
					2944   
					Studio   
					Corner   
					Zero   
					(5/8")   
					L 83-15/16" (2132mm)   
					W 61-3/8" (1559mm)   
					H 21-1/2" (546mm)   
					A 15"   
					C 20-7/8"   
					(530mm)   
					N/A   
					(381mm)   
					B 13-1/2"   
					(343mm)   
					988 lb. (448 kg)/   
					27 lb./sq.ft.   
					(133 kg/sq.m)   
					130 lb.   
					(59 kg.)   
					103 gal.   
					(390 l.)   
					65 gal.   
					(246 l.)   
					2944   
					Studio   
					Corner   
					2"   
					L 84-1/4" (2139mm)   
					W 31-13/16" (808mm)   
					H 21-1/2" (546mm)   
					A 15"   
					C 19-1/2"   
					(495mm)   
					N/A   
					(381mm)   
					B 13-5/8"   
					(346mm)   
					TABLE 7   
					ROUGH-IN REFERENCES   
					MODEL SERIES 2944   
					59-3/4" NOMINAL   
					(1518mm)   
					OUTLINE   
					OF CUTOUT   
					61-3/4" NOMINAL   
					(1568mm)   
					9" x 18"   
					(229 x 457mm)   
					FLOOR CUTOUT   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					NOTE: PUMP EXTENDS   
					APPROXIMATELY   
					1-1/4" BEYOND TUB DECK   
					27-1/2"   
					(699mm)   
					45-5/8"L   
					(1159mm)   
					84" NOMINAL   
					(2134mm)   
					754532-100 Rev. A   
					18   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR STUDIO CORNER WHIRLPOOLS AND BATH TUBS   
					Description   
					Deck   
					Trim   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Weight   
					Overflow Operating   
					Volume   
					54 gal.   
					(246 l.)   
					N/A   
					N/A   
					597 lb. (271 kg)/   
					45 lb./sq.ft.   
					(219 kg/sq.m)   
					57 lb.   
					(26 kg.)   
					N/A   
					2945   
					Studio   
					L 60" (1524mm)   
					W 32" (813mm)   
					H 22" (559mm)   
					A 15-3/4"   
					(400mm)   
					B 10-1/4"   
					(260mm)   
					C 22-1/2"   
					(572mm)   
					60-3/16"   
					(1528mm)   
					x 30-1/2"   
					(774mm)   
					TABLE 8   
					ROUGH-IN REFERENCES   
					MODEL SERIES 2945   
					60"   
					(1524mm)   
					4"   
					10-1/4"   
					(260mm)   
					(102mm)   
					1-1/2"   
					(38mm)   
					16-3/8"   
					(411mm)   
					32"   
					(813mm)   
					4"   
					(102mm)   
					57"   
					(1448mm)   
					1-1/2"   
					(38mm)   
					2"(50mm)   
					OUTLINE   
					DRAIN O.D.   
					OF SKID   
					RESISTANT   
					SURFACE   
					754532-100 Rev. A   
					19   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR GREEN TEA WHIRLPOOLS AND BATH TUBS   
					Description   
					Dimensions   
					L-W-H   
					Drain /   
					Overflow   
					Height to   
					Underside   
					of Deck: C   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product   
					Weight   
					Gallon to   
					Overflow   
					Whirlpool   
					Operating   
					Volume   
					L 60" (1524mm)   
					W 36" (914mm)   
					H 21" (533mm)   
					3571   
					Green Tea   
					5' x 36"   
					A 16"   
					C 19"   
					(483mm)   
					58-1/2"   
					60-3/16"   
					(1529mm)   
					x 34-1/2"   
					(876mm)   
					3-1/2"   
					(89mm)   
					519 lb. (236 kg)/   
					35 lb./sq.ft.   
					(171 kg/sq.m)   
					86 lb.   
					(39 kg.) (197 l.)   
					52 gal.   
					38 gal.   
					(144 l.)   
					(406mm)   
					B 11-1/2"   
					(349mm)   
					(1485mm)   
					x 34-1/2"   
					(876mm)   
					3572   
					Green Tea   
					5-1/2' x 36"   
					A 16"   
					C 19"   
					(483mm)   
					64-1/2"   
					66-3/16"   
					(1681mm)   
					x 34-1/2"   
					(876mm)   
					3-3/4"   
					(95mm)   
					592 lb. (269 kg)/   
					36 lb./sq.ft.   
					(176 kg/sq.m)   
					100 lb.   
					(45 kg.) (223 l.)   
					59 gal.   
					44 gal.   
					(166 l.)   
					L 66" (1676mm)   
					W 36" (914mm)   
					H 21" (533mm)   
					(406mm)   
					B 11-1/2"   
					(349mm)   
					(1638mm)   
					x 34-1/2"   
					(876mm)   
					3573   
					Green Tea   
					6' x 36"   
					A 16"   
					C 19"   
					(483mm)   
					70-1/2"   
					72-3/16"   
					(1834mm)   
					x 34-1/2"   
					(876mm)   
					3-1/2"   
					(89mm)   
					665 lb. (302 kg)/   
					37 lb./sq.ft.   
					(181 kg/sq.m)   
					115 lb.   
					(52 kg.) (250 l.)   
					66 gal.   
					49 gal.   
					(185 l.)   
					L 72" (1829mm)   
					W 36" (914mm)   
					H 21" (533mm)   
					(406mm)   
					B 11-1/2"   
					(349mm)   
					(1791mm)   
					x 34-1/2"   
					(876mm)   
					3574   
					Green Tea   
					5' x 42"   
					A 16"   
					C 19"   
					(483mm)   
					58-1/2"   
					60-3/16"   
					3-1/8"   
					(79mm)   
					656 lb. (298 kg)/   
					38 lb./sq.ft.   
					(186 kg/sq.m)   
					115 lb.   
					(52 kg.) (246 l.)   
					65 gal.   
					47 gal.   
					(178 l.)   
					L 72" (1829mm)   
					W 42" (1067mm)   
					H 21" (533mm)   
					(406mm)   
					B 11-1/2"   
					(349mm)   
					(1485mm)   
					x 40-1/2"   
					(1029mm)   
					(1528mm)   
					x 40-1/2"   
					(1029mm)   
					3575   
					Green Tea   
					6' x 42"   
					A 16"   
					C 19"   
					(483mm)   
					70-1/2"   
					72-3/16"   
					3-1/2"   
					(89mm)   
					785 lb. (356 kg)/   
					37 lb./sq.ft.   
					(181 kg/sq.m)   
					127 lb.   
					(57 kg.) (299 l.)   
					79 gal.   
					58 gal.   
					(219 l.)   
					L 72" (1829mm)   
					W 42" (1067mm)   
					H 21" (533mm)   
					(40mm)   
					B 11-1/2"   
					(349mm)   
					(1791mm)   
					x 40-1/2"   
					(1029mm)   
					(1834mm)   
					x 40-1/2"   
					(1029mm)   
					TABLE 9   
					754532-100 Rev. A   
					20   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 3571   
					60"   
					(1524mm)   
					14-3/4"   
					(375mm)   
					11-1/2"   
					(292mm)   
					36"   
					(914mm)   
					9"   
					C 
					L 
					(229mm)   
					CUTOUT IN FLOOR FOR DRAIN   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					OUTLINE OF CUTOUT 58.5" x 34.5"(1486 x 876mm)   
					MODEL SERIES 3572   
					66"   
					(1676mm)   
					14-3/4"   
					(375mm)   
					11-1/2"   
					(292mm)   
					36"   
					(914mm)   
					9"   
					C 
					L 
					(229mm)   
					CUTOUT IN FLOOR FOR DRAIN   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					OUTLINE OF CUTOUT 64.5" x 34.5" (1638 x 876mm)   
					754532-100 Rev. A   
					21   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 3573   
					72"   
					(1829mm)   
					14-3/4"   
					(375mm)   
					11-1/2"   
					(292mm)   
					36"   
					(914mm)   
					9"   
					C 
					L 
					(229mm)   
					CUTOUT IN FLOOR FOR DRAIN   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					OUTLINE OF CUTOUT 70.5" x 34.5" (1780 x 876mm)   
					MODEL SERIES 3574   
					60"   
					(1524mm)   
					14-3/4"   
					(375mm)   
					11-1/2"   
					(292mm)   
					42"   
					(1067mm)   
					9"   
					C 
					L 
					(229mm)   
					CUTOUT IN FLOOR FOR DRAIN   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					OUTLINE OF CUTOUT 58.5" x 40.5" (1486 x 1029mm)   
					754532-100 Rev. A   
					22   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 3575   
					72"   
					(1829mm)   
					14-3/4"   
					(375mm)   
					11-1/2"   
					(292mm)   
					42"   
					(1067mm)   
					9"   
					C 
					L 
					(229mm)   
					CUTOUT IN FLOOR FOR DRAIN   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					OUTLINE OF CUTOUT 70.5" x 40.5" (1780 x 1029mm)   
					754532-100 Rev. A   
					23   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS:   
					L 
					W 
					J 
					H 
					C 
					A 
					SIDE VIEW   
					END VIEW   
					DRAIN / OVERFLOW   
					B 
					GENERAL SPECIFICATIONS FOR SERIN WHIRLPOOLS AND BATH TUBS   
					Description   
					Dimensions   
					L-W-H   
					Drain /   
					Height to   
					Cut Out   
					Pier   
					G x F   
					Rough-In   
					Recess   
					E x D   
					Tub Edge to   
					Centerline   
					Overflow: J   
					Weight with   
					Water / Floor   
					Loading   
					Product Gallon to Whirlpool   
					Overflow Underside   
					of Deck: C   
					Weight   
					Overflow Operating   
					Volume   
					A 16-3/4" C 20"   
					(425mm) (508mm)   
					B 10-1/4"   
					58-1/2"   
					60-3/16"   
					(1529mm)   
					x 30-1/2"   
					(775mm)   
					597 lb. (271 kg)/   
					45 lb./sq.ft.   
					(219 kg/sq.m)   
					57 lb.   
					(26 kg.) (246 l.)   
					54 gal.   
					L 60" (1524mm)   
					W 32" (813mm)   
					H 23" (584mm)   
					3581   
					Serin   
					5' x 32"   
					(1486mm)   
					x 30-1/2"   
					(775mm)   
					(260mm)   
					A 16-7/8" C 20"   
					(429mm) (508mm)   
					B 9-3/4"   
					64-1/2"   
					66-3/16"   
					(1681mm)   
					x 34-1/2"   
					(876mm)   
					806 lb. (365 kg)/   
					49 lb./sq.ft.   
					(239 kg/sq.m)   
					65 lb.   
					(29 kg.) (441 l.)   
					97 gal.   
					L 66" (1676mm)   
					W 36" (914mm)   
					H 23" (584mm)   
					3582   
					Serin   
					5-1/2' x 36"   
					(1638mm)   
					x 34-1/2"   
					(876mm)   
					(248mm)   
					A 17-1/4" C 20"   
					(438mm) (508mm)   
					B 11-1/2"   
					68-3/16"   
					(1732mm)   
					x 36-1/2"   
					(927mm)   
					680 lb. (308 kg)/   
					68 lb./sq.ft.   
					(331 kg/sq.m)   
					60 lb.   
					(27 kg.) (409 l.)   
					90 gal.   
					L 68" (1727mm)   
					W 38" (965mm)   
					H 23" (584mm)   
					Template   
					Provided   
					3583   
					Serin   
					Oval   
					(292mm)   
					A 17"   
					(432mm) (508mm)   
					B 10-1/4"   
					C 20"   
					1043lb. (473 kg)/   
					50 lb./sq.ft.   
					(243 kg/sq.m)   
					68 lb.   
					(31 kg.) (568 l.)   
					125 gal.   
					L 72" (1829mm)   
					W 42" (1067mm)   
					H 23" (584mm)   
					72-3/16"   
					70-1/2"   
					3584   
					Serin   
					6' x 42"   
					(1834mm)   
					x 40-1/2"   
					(1029mm)   
					(1791mm)   
					x 40-1/2"   
					(1029mm)   
					(260mm)   
					TABLE 10   
					ROUGH-IN REFERENCES   
					MODEL SERIES 3581   
					C 
					L 
					60"   
					(1524mm)   
					OVERFLOW   
					30"   
					(762mm)   
					9-3/4"   
					(248mm)   
					4-1/8"   
					(105mm)   
					32"   
					(813mm)   
					9" x 12" (227 x 305mm)   
					CUTOUT IN FLOOR   
					FOR DRAIN   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					INTEGRAL   
					FITTING DECK   
					OUTLINE OF CUTOUT   
					754532-100 Rev. A   
					24   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 3582   
					66"   
					(1676mm)   
					33"   
					(838mm)   
					9" x 12" (227 x 305mm)   
					FLOOR CUTOUT   
					C/L   
					DRAIN   
					9-3/4"   
					(248mm)   
					4-1/8"   
					(105mm)   
					OUTLINE OF   
					CUTOUT   
					36"   
					(914mm)   
					INTEGRAL   
					FAUCET DECK   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					4"   
					(102mm)   
					MODEL SERIES 3583   
					68"   
					(1727mm)   
					34"   
					(864mm)   
					C/L   
					DRAIN   
					9"x12" (227x305mm)   
					FLOOR CUTOUT   
					11-1/2"   
					(292mm)   
					4-7/8"   
					(124mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					INTEGRAL   
					FAUCET DECK   
					OUTLINE OF   
					SKID RESISTANT   
					SURFACE   
					OUTLINE OF CUTOUT   
					4-3/4"   
					(121mm)   
					USE CUT-OUT TEMPLATE SUPPLLIED WITH PACKAGED TUB   
					754532-100 Rev. A   
					25   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ROUGH-IN REFERENCES   
					MODEL SERIES 3584   
					72"   
					(1829mm)   
					36"   
					(914mm)   
					9" x 12" (227 x 305mm)   
					FLOOR CUTOUT   
					C/L   
					DRAIN   
					10-1/4"   
					(260mm)   
					4-7/8"   
					(124mm)   
					42"   
					(1067mm)   
					PROVIDE ACCESS   
					TO PUMP   
					SERVING ON   
					ALL INSTALLATIONS   
					INTEGRAL   
					FAUCET DECK   
					OUTLINE OF   
					OUTLINE OF   
					SKID RESISTANT   
					SURFACE   
					CUTPUT   
					754532-100 Rev. A   
					26   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL INSTALLATION INSTRUCTIONS   
					All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes.   
					WARNING: When using electrical products, basic precautions should always be observed, including the following:   
					1. DANGER: RISK OF ELECTRIC SHOCK! Connect only to a circuit protected by a ground-fault circuit interrupter.   
					2. Grounding is required. The unit should be installed by a licensed electrician and grounded.   
					3. Permit access for servicing motor as noted.   
					! 
					4. All building materials and wiring should be routed away from the pump body and heater (if equipped).   
					Refer to the schematics below for the appropriate bath electrical installation. Dedicated15A circuits with GFCI (Ground   
					Fault Circuit Interrupter) protection are required.   
					At initial start-up with the power ON, push the GFCI test button. The reset button should pop out. Push this button in to   
					reset. If the GFCI fails to operate in this manner, there is a ground fault or malfunction, indicating the possibility of   
					electrical shock. Turn of the power and do not use until the source of the problem has been identifed and corrected.   
					AIR SWITCH ACTIVATED WHIRLPOOL PUMP   
					ELECTRICAL   
					120V, 60HZ   
					15A GFCI   
					FEED   
					GFCI   
					ELECTRICAL   
					120V, 60HZ   
					15A GFCI   
					FEED   
					JUNCTION BOX (CANADA)   
					White   
					GFCI   
					Black   
					Green/Copper   
					GFCI OUTLET (USA)   
					754532-100 Rev. A   
					27   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL INSTALLATION INSTRUCTIONS (continued)   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					GFCI   
					ELECTRONIC ACTIVATED AIR BATH (4 BUTTON PANEL)   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					GFCI   
					ELECTRONIC ACTIVATED AIR BATH WITH LIGHTS (5 BUTTON PANEL)   
					754532-100 Rev. A   
					28   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL INSTALLATION INSTRUCTIONS (continued)   
					ECOSILENT PUMP HAS P3JJ PLUG   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					GFCI   
					ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL (1 BUTTON PANEL)   
					ECOSILENT PUMP HAS P3JJ PLUG   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					GFCI   
					ELECTRONIC ACTIVATED ECOSILENT WHIRLPOOL WITH LIGHTS (3 BUTTON PANEL)   
					754532-100 Rev. A   
					29   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL INSTALLATION INSTRUCTIONS (continued)   
					USE THREE GFCI OUTLETS (USA MARKET)   
					WHIRLPOOL HEATER IS   
					120V, 60HZ   
					ELECTRICAL   
					FEED   
					FACTORY INSTALLED ON   
					15A GFCI   
					COMBINATION TUBS   
					(FOR HEATER)   
					GFCI   
					ECOSILENT PUMP   
					HAS P3JJ PLUG   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					GFCI   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					GFCI   
					ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL)   
					754532-100 Rev. A   
					30   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL INSTALLATION INSTRUCTIONS (continued)   
					USE THREE JUNCTION BOXES   
					(CANADA MARKET)   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					(FOR HEATER)   
					GFCI   
					White   
					Black   
					Green/Copper   
					WHIRLPOOL HEATER IS   
					FACTORY INSTALLED ON   
					COMBINATION TUBS   
					ECOSILENT PUMP   
					HAS P3JJ PLUG   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					GFCI   
					White   
					Black   
					TO   
					BOX   
					Green/Copper   
					ELECTRICAL   
					FEED   
					120V, 60HZ   
					15A GFCI   
					TO   
					BOX   
					GFCI   
					White   
					Black   
					Green/Copper   
					ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL)   
					754532-100 Rev. A   
					31   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL INSTALLATION INSTRUCTIONS   
					(continued)   
					(HEATER)   
					Ensure the heater and pump are properly GROUNDED   
					and BONDED as required. Attach the 8 AWG solid   
					copper conductor supplied with the heater from the   
					heater bonding lug to the motor frame bonding lug as   
					shown in Figure 3.   
					(PUMP/MOTOR)   
					The conductor is secured to the lugs using set screws.   
					The motor frame shall have a second 8 AWG solid   
					copper conductor connected from the frame bonding   
					lug to the home’s electrical panel or approved local   
					bonding point as shown in Figure 3.   
					RUN 8 AWG SOLID COPPER   
					CONDUCTORS FROM   
					HEATER BONDING LUG TO   
					PUMP/MOTOR FRAME LUG   
					AND FROM PUMP/MOTOR   
					LUG TO APPROVED   
					NOTE: For all “EcoSilent” pump configurations, the   
					pump housing is plastic. Therefore, the first copper   
					conductor attached to the heater must be grounded   
					directly to the home’s electrical panel or approved local   
					bonding point. this type of configuration does not need   
					the second copper conductor shown in Figure 3.   
					GROUND AS SHOWN   
					FIRST COPPER   
					CONDUCTOR   
					SECOND   
					COPPER   
					CONDUCTOR   
					PUMP/MOTOR FRAME WITH   
					BONDING LUGS   
					(NOT ON “ECOSILENT” MODELS)   
					TO GROUND   
					FIGURE 3: GROUNDING DIAGRAM   
					WHIRLPOOL HEATER OPERATION   
					WARNING: Prior to operation, review the Important Safety   
					Instructions listed at the beginning of this instruction manual.   
					Once the heater is installed and the whirlpool pump is operating,   
					the heater is totally automatic. The heater will help maintain the   
					temperature of the water in the bath.   
					WHIRLPOOL   
					HEATER   
					ALL™   
					E-Z INST   
					HEATER “ON” LIGHT   
					Pressure Switch   
					FACTORY INSTALLED - NOT FOR RESALE   
					HEATER P/N: 753174-100   
					Bonding Lug on   
					Heater Housing   
					The heater is equipped with a preset pressure switch. The pump   
					must be running with water flowing in the whirlpool to allow the   
					heater to turn on.   
					FIGURE 4: WHIRLPOOL HEATER   
					INDICATOR LIGHT   
					Indicator Light   
					This light turns on whenever the heater is operating.   
					High-Limit Switch   
					The heater includes an exclusive “Intelligent High-Limit”. This safety circuit will not “false trip” from hot tap water.   
					It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician.   
					To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply   
					(1) Turn off the whirlpool pump.   
					(2) Drain water from the tub.   
					(3) Remove power from heater by unplugging at receptacle or turning off circuit breaker.   
					(4) The heater circuit will automatically reset in less than 15 minutes.   
					(5) Restore power to the heater.   
					(6) Whirlpool bath is now ready to use.   
					754532-100 Rev. A   
					32   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				REMOTE BLOWER LOCATION OPTION   
					IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular   
					installation makes this effort practical.   
					NOTE: Relocating blower motor from factory installed location, see photo 1, will require disassembly of air blower from mounting   
					board. Keep all hardware for reattachment at new location. Additional hardware will be required depending upon final   
					desired position of air blower. Follow all instructions listed below.   
					1.   
					TYPICAL VIEW   
					NOTE: Installing the blower in a remote location will reduce the system efficiency.   
					NOTE: Relocating a blower motor still requires a service access for the blower.   
					NOTE: All materials needed for the relocation must be supplied by the installer. This includes ordering a longer control panel   
					cable (754025-0073A), a longer flexible blower hose (753960-2030A), and up to two lighting cable extensions for combo   
					models (754512-0070A).   
					A separate circuit, which must be protected by the Ground Fault Circuit Interrupter (GFCI), is required in the remote location.   
					Electrical connections should be performed by a licensed electrician.   
					The blower motor must be located within 12 feet of rigid piping from the bath air manifold. This limitation is for the total pipe length   
					and applies to any direction changes and elbows. There can be no more than six changes of direction. There should be as few   
					direction changes as possible and the piping installation must meet all requirements of local plumbing and building codes.   
					Disconnect the blower from the flexible hose as shown in photo 2. Do NOT remove the check valve manifold that is mounted to the   
					underside of the air bath. The manifold MUST remain mounted above the tub overflow level as shown in 2.   
					2.   
					Do NOT move check   
					valve manifold   
					TYPICAL VIEW   
					Replace the flexible hose shown in photo 2 with the longer flexible hose (P/N 753960-2030A) using the existing hope clamps.   
					NOTE: Do NOT remove the original cable coming out of the blower. Instead, plug the longer cable (P/N 754025-0073A) into the   
					existing cable that is coming out of the blower as shown in photo 3. Then plug the remaining end of the longer cable into   
					the control panel which remains on the tub wall.   
					TO CONTROL PANEL   
					TO BLOWER   
					3.   
					754025-0073A CABLE   
					(INCLUDES ADAPTER   
					BOX SHOWN)   
					EXISTING   
					CABLE   
					754532-100 Rev. A   
					33   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				REMOTE BLOWER LOCATION OPTION (continued)   
					FOR THE COMBINATION WHIRLPOOL / AIR BATH CONFIGURATIONS ONLY:   
					Up to two additional control box extensions (P/N 754512-0070A) are required as shown in photo 4 (below). Simply extend the   
					cables going to the blower by adding in the extension cables. Be careful not to damage the cable connections and never plug in   
					cables while power is applied to blower and/or pump.   
					PUMP   
					LONGER CONTROL PANEL CABLE   
					(754025-0073A)   
					CONTROL PANEL   
					4.   
					BLOWER   
					LIGHTS   
					CONTROL BOX EXTENSIONS   
					(754512-0070A)   
					754532-100 Rev. A   
					34   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation: Single Speed Whirlpool   
					AIR SWITCH   
					ELECTRONIC SWITCH   
					BATHING:   
					• Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the   
					optional EZ-Heater, it will automatically maintain the water temperature.   
					• IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow.   
					• IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump.   
					• IMPORTANT: Water level must be at least one inch (25mm) above the highest jet before the whirlpool is started.   
					Operating the system without water (dry running) for extended periods will cause pump damage and void the warranty.   
					• IMPORTANT: The EcoSilent whirlpool will NOT operate unless the water level is at least one inch above   
					the highest jet.   
					STARTING WHIRLPOOL:   
					• Press on/off button to start whirlpool.   
					STOPPING WHIRLPOOL:   
					• Press on/off button again to stop whirlpool.   
					AIR VOLUME CONTROL ADJUSTMENTS:   
					• Water turbulence is determined by the amount of air mixed with the water. Rotate the air volume control   
					counterclockwise for more turbulence, and clockwise for less.   
					FLOW JET VOLUME ADJUSTMENTS:   
					• Water flow-levels can be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and   
					clockwise for soft.   
					• The water flow to the mini-jets in the lumbar area of bath (if so equipped) can be adjusted by turning the mini-jet   
					flow control valve open (counterclockwise) or closed (clockwise). the mini-jets themselves are NOT adjustable.   
					754532-100 Rev. A   
					35   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation: EcoSilent Whirlpool with Lights   
					DISPLAY COLORS   
					ST   
					1 
					WHITE   
					SLOW RAINBOW CYCLE   
					FAST RAINBOW CYCLE   
					TURQUOISE   
					ND   
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					TH   
					TH   
					TH   
					TH   
					TH   
					TH   
					TH   
					BLUE   
					MAGENTA   
					RED   
					ORANGE   
					3-BUTTON ELECTRONIC SWITCH   
					YELLOW   
					TH   
					TH   
					10   
					11   
					GREEN   
					RETURN TO SLOW RAINBOW CYCLE   
					BATHING:   
					• Fill bath with water at a comfortable bathing temperature - If your whirlpool is equipped with the optional EZ-Heater,   
					it will automatically maintain the water temperature.   
					• IMPORTANT: Do NOT fill the whirlpool more than 2/3 full before getting in, as it may overflow.   
					• IMPORTANT: Do NOT add bath oils or salts – this will damage the whirlpool pump.   
					• IMPORTANT: Water level must be at least one inch (25mm) above the highest jet before the whirlpool is started.   
					Operating the system without water (dry running) for extended periods will cause pump damage and void the warranty.   
					• IMPORTANT: The EcoSilent whirlpool will NOT operate unless the water level is at least one inch above   
					the highest jet.   
					• To start whirlpool pump, press “on” button.   
					• To stop whirlpool pump, press “off” button.   
					• To turn on Chromatherapy lights, press light button once.The cycle will start on white.   
					• Turn off and on within 3 seconds; it will change to slow rainbow cycle and so on per the   
					display color table shown above.   
					AIR VOLUME CONTROL ADJUSTMENTS:   
					• Water turbulence is determined by the amount of air mixed with the water. Rotate the air volume control   
					counterclockwise for more turbulence, and clockwise for less.   
					FLOW JET VOLUME ADJUSTMENTS:   
					• Water flow-levels can be adjusted from vigorous to soft by rotating the nozzle counterclockwise for vigorous and   
					clockwise for soft.   
					• The water flow to the mini-jets in the lumbar area of bath (if so equipped) can be adjusted by turning the mini-jet   
					flow control valve open (counterclockwise) or closed (clockwise). the mini-jets themselves are NOT adjustable.   
					754532-100 Rev. A   
					36   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation: Air Bath   
					BATHING:   
					• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE   
					• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.   
					OPERATING AIR MASSAGE SYSTEM:   
					ON/OFF:   
					Press this button once to turn air-blower on.   
					Press again to turn air-blower off.   
					AIR SPEED INCREASE:   
					Pressing this button will increase to the next higher speed.   
					AIR SPEED DECREASE:   
					Pressing this button will decrease to the next lower speed.   
					WAVE FUNCTION:   
					Press this button to start the wave function (button will light).   
					Blower speed will continuously vary between high and low.   
					Press again to exit wave function (button light will go out).   
					EXITING THE BATH   
					• Be sure to turn off the air blower before draining bath.   
					• Open drain by rotating drain knob clockwise.   
					DRYING CYCLE OPTIONS   
					STANDARD DRYING CYCLE   
					An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the   
					purge cycle.   
					24H PROGRAMMABLE DRYING CYCLE   
					The system must be stopped prior to activation or deactivation.   
					Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button on   
					the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24 hrs. In   
					the event of a power failure, the program will be automatically deactivated.   
					Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm deactivation.   
					754532-100 Rev. A   
					37   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation: Air Bath with Lights   
					BATHING:   
					• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE   
					• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.   
					OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM:   
					ON/OFF:   
					Press this button once to turn air-blower on.   
					Press again to turn air-blower off.   
					AIR SPEED INCREASE:   
					Pressing this button will increase to the next higher speed.   
					AIR SPEED DECREASE:   
					Pressing this button will decrease to the next lower speed.   
					WAVE FUNCTION:   
					Press this button to start the wave function (button will light).   
					Blower speed will continuously vary between high and low.   
					Press again to exit wave function (button light will go out).   
					DISPLAY COLORS   
					ST   
					1 
					WHITE   
					SLOW RAINBOW CYCLE   
					FAST RAINBOW CYCLE   
					TURQUOISE   
					ND   
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					TH   
					TH   
					TH   
					TH   
					TH   
					TH   
					TH   
					BLUE   
					MAGENTA   
					RED   
					ORANGE   
					YELLOW   
					TH   
					TH   
					10   
					11   
					GREEN   
					RETURN TO SLOW RAINBOW CYCLE   
					• To turn on Chromatherapy lights, press light button once.   
					The cycle will start on white.   
					• Turn off and on within 3 seconds; it will change to slow rainbow   
					cycle and so on per the display color table shown above.   
					754532-100 Rev. A   
					38   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation: Air Bath with Lights (continued)   
					EXITING THE BATH   
					• Be sure to turn off the air blower before draining bath.   
					• Open drain by rotating drain knob clockwise.   
					DRYING CYCLE OPTIONS   
					STANDARD DRYING CYCLE   
					An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the   
					purge cycle.   
					24H PROGRAMMABLE DRYING CYCLE   
					The system must be stopped prior to activation or deactivation.   
					Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button   
					on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24   
					hrs. In the event of a power failure, the program will be automatically deactivated.   
					Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm   
					deactivation.   
					754532-100 Rev. A   
					39   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation: Combination Tub with Lights   
					BATHING:   
					• Close drain by rotating Drain Overflow Knob COUNTER-CLOCKWISE   
					• Fill bath with water at a comfortable bathing temperature, adding bath oils or salts as desired.   
					OPERATING AIR MASSAGE and CHROMATHERAPY SYSTEM:   
					• Press this button to turn blower on.   
					• Press this button again to turn blower off.   
					• Press and hold button to increase blower speed. Release button   
					at desired speed.   
					• Press and hold button to decrease speed. Release button at   
					desired speed.   
					• Press button to turn whirlpool pump on.   
					• Press button to turn whirlpool pump off.   
					DISPLAY COLORS   
					ST   
					1 
					WHITE   
					SLOW RAINBOW CYCLE   
					FAST RAINBOW CYCLE   
					TURQUOISE   
					ND   
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					TH   
					TH   
					TH   
					TH   
					TH   
					TH   
					TH   
					BLUE   
					MAGENTA   
					RED   
					ORANGE   
					YELLOW   
					TH   
					TH   
					10   
					11   
					GREEN   
					RETURN TO SLOW RAINBOW CYCLE   
					• To turn on Chromatherapy lights, press light button once.   
					The cycle will start on white.   
					• Turn off and on within 3 seconds; it will change to slow rainbow   
					cycle and so on per the display color table shown above.   
					754532-100 Rev. A   
					40   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operation: Combination Tub with Lights (continued)   
					EXITING THE BATH   
					• Be sure to turn off the air blower before draining bath.   
					• Open drain by rotating drain knob clockwise.   
					DRYING CYCLE OPTIONS   
					STANDARD DRYING CYCLE   
					An automatic drying cycle will start 20 minutes after the blower is turned off. The blower LED blinks while waiting for the   
					purge cycle.   
					24H PROGRAMMABLE DRYING CYCLE   
					The system must be stopped prior to activation or deactivation.   
					Activation: Determine at which time you wish to purge to activate. At that precise time, press and hold the second button   
					on the keypad for 5 seconds, all LEDs will flash twice. The purge cycle will now start at the programmed time every 24   
					hrs. In the event of a power failure, the program will be automatically deactivated.   
					Deactivation: Press and hold the second button on the keypad for 5 seconds, all LEDs will flash once to confirm   
					deactivation.   
					754532-100 Rev. A   
					41   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Your American Standard whirlpool is designed to give you many years of pleasure with reasonable care and   
					maintenance.   
					Your new acrylic bathtub is tough, durable and easy to care for. The colors have been formulated to match other   
					American Standard fixtures and enhance your choice of bathroom decorations. The high gloss surface will retain its   
					lasting luster with proper care and maintenance.   
					CLEANING AND MAINTENANCE:   
					• Always fill the tub with temperate water. Excessively hot water (greater than 130˚ F) may cause surface damage.   
					• Remove bath mat after use and hang to dry.Allowing bath mat to dry in the tub may cause surface damage.   
					• Clean after use with a mild liquid household detergent cleaner. Do not turn on jets when such cleaners are present.   
					Do not use: Lestoil® Cleaner; Lysol® Disinfectant (spray or concentrate); or Lysol® Basin, Tub and Tile Cleaner;   
					Windex® Cleaner; Mr. Clean® Cleaner; Dow® Disinfectant Bathroom Cleaner*; or other cleaning products in   
					aerosol cans.   
					HARSH CHEMICALS, SHARP AND ABRASIVE OBJECTS   
					SHOULD NEVER BE USED ON ACRYLIC SURFACES   
					• Do not use wire brushes, knives or sharp objects to remove stains or other surface blemishes.   
					• Use of abrasive cleaners or powders will dull the surface. If the glossy surface looses its sheen, dulled areas can   
					be partially restored by rubbing with a white automotive body polishing compound and waxing with a liquid wax.   
					Do not wax surfaces where you walk or stand.   
					• Do not allow nail polish remover, acetone, dry-cleaning fluid, paint remover, or other solvents to come into contact   
					with the surface.   
					• Clean the surrounding surface immediately after using caustic drain cleaners.   
					Do not permit drain cleaner to enter circulation system.   
					• Burning cigarettes will irreparably damage the surface of the whirlpool.   
					CLEANING/PURGING THE CIRCULATION SYSTEM   
					Once every month the circulating system must be purged and cleaned. Follow the steps outlined below:   
					Fill whirlpool with warm water and add two teaspoons of powdered automatic dishwasher (not laundry)   
					detergent and one-half cup of household bleach to filled whirlpool.   
					1.   
					Activate whirlpool system in accordance with operating instructions and run system for two minutes.   
					Drain and refill whirlpool with cold water. Circulate for five minutes.   
					2.   
					3.   
					4.   
					Drain whirlpool completely after step 3 (above) is completed.   
					
					* Lestoil® is a registered trademark of The Clorox Company.   
					Lysol® is a registered trademark of The Linden Company.   
					Windex® is a registered trademark of S.C. Johnson and Son, Inc.   
					Mr. Clean® is a registered trademark of The Proctor and Gamble Company.   
					Dow® is a registered trademark of The Dow Chemical Company.   
					754532-100 Rev. A   
					42   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				AS America, Inc. Limited Lifetime Warranty for Premium Acrylic Air Baths   
					AS America, Inc. (”American Standard”) warrants to the original consumer purchaser that it will, at its option,   
					repair or replace this whirlpool or any of its parts that are found by American Standard, in its sole judgment,   
					to be defective under normal residential use and maintenance so long as it is owned by the original   
					consumer purchaser.   
					This warranty shall only become effective upon receipt by American Standard of a completely filled out   
					Warranty Registration Card evidencing proof of purchase.   
					This limited warranty does not apply to commercial installations. The warranty for commercial installations is   
					three (3) years.   
					THIS WARRANTY SHALL BE VOID IF THE ACCESS PANEL TO THE WHIRLPOOL IS COVERED IN ANY   
					MANNER CONTRARY TO THE INSTALLATION INSTRUCTIONS. In no event will American Standard be   
					liable for the cost of repair or replacement of any installation materials including but not limited to tiles, marble   
					etc.   
					This limited warranty DOES NOT COVER the following:   
					1. Defects or damages arising from shipping, installation, alterations, accidents, abuse, misuse, lack of   
					proper maintenance and cleaning as directed in the owner’s manual and use of other than genuine   
					American Standard replacement parts, in all cases whether caused by a plumbing contractor, service   
					company, the owner or any other person.   
					2. Deterioration through normal wear and tear and the expense of normal maintenance.   
					3. Commercial application.   
					4. Options and accessories. American Standard’s limited warranty on these items is one year for parts only   
					and excludes labor. This one year limited warranty covers accessories manufactured by American   
					Standard (e.g. aprons, drains, grab bars, heaters, trim kits) against defects of material or workmanship.   
					Warranty coverage begins on the date the accessory was originally purchased by the owner.   
					5. Postage or shipping costs for returning products for repairs or replacement under this limited warranty and   
					labor or other costs incurred in connection with product removal or installation under this limited warranty.   
					6. ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, ALL OF WHICH ARE HEREBY   
					EXPRESSLY DISCLAIMED, OR THE EXTENSION BEYOND THE DURATION OF THIS LIMITED   
					WARRANTY OF ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY OR   
					FITNESS FOR AN INTENDED PURPOSE. (Some jurisdictions do not allow limitations on how long an   
					implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so these   
					limitations and exclusions may not apply to you.)   
					7. Responsibility for compliance with local code requirements. (Since local code requirements vary greatly   
					distributors, retailers, dealers, installation contractors and users of plumbing products should determine   
					whether there are any code restrictions on the installation or use of a specific product.)   
					This warranty gives you specific legal rights. You may have other legal rights that vary from state to state.   
					For service under this warranty, you should contact the following:   
					By Telephone:   
					1-800-442-1902   
					By Mail: American Standard Brands   
					P.O. Box 6820   
					Piscataway, N.J. 08855   
					Attention: Customer Care Center   
					754532-100 Rev. A   
					43   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				754532-100 Rev. A   
					44   