AD-24 Installation Manual
Phase 7
AVERTISSEMENT:Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
WARNING: For your safety the information
in this manual must be followed to
minimize the risk of fire or explosion and
to prevent property damage, personal
injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
—Ne pas entreposer ni utiliser d’essence
ni d’autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
— WHAT TO DO IF YOU SMELL GAS:
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
ꢀ
ꢀ
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas
supplier, call the fire department.
ꢀ
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne
ꢀ
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
ꢀ
ꢀ
ꢀ
zone.
ꢀ
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
ꢀ
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
ꢀ
fournisseur de gaz, appelez le service
des incendies.
— Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
—L’installation et l’entretien doivent être
assurés par un installateur ou un
service d’entretien qualifié ou par le
fournisseur de gaz.
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: [email protected]
ADC Part No. 113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
!
ꢀꢀWARNING
Proposition 65
Use of this product could expose you to substances from fuel combustion
that contain chemicals known to the State of California to cause cancer,
birth defects and other reproductive harm.
IMPORTANT
YOU MUSTDISCONNECTAND LOCKOUTTHE ELECTRIC SUPPLYANDTHE GAS
SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE
REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING,
ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA
(Occupational Safety and HealthAdministration) STANDARDS.
“Caution: Label all wires prior to
disconnection when servicing
controls. Wiring errors can cause
improper operation.”
«Attention:Au moment de l’entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des
erreurs de câblage peuvent entraîner un fonctionnement
inadéquat et dangereux.»
CAUTION
DRYERS SHOULD NEVER BE LEFTUNATTENDEDWHILE IN OPERATION.
WARNING
CHILDREN SHOULD NOT BEALLOWED TO PLAYON OR NEAR THE DRYER(S).
CHILDREN SHOULD BE SUPERVISED IFNEAR DRYERS IN OPERATION.
FORYOUR SAFETY
DO NOT DRYMOPHEADS INTHE DRYER.
DO NOT USE DRYER INTHE PRESENCE OF DRYCLEANING FUMES.
WARNING
UNDER NO CIRCUMSTANCES should the dryer door switch, lint door switch, or
heat safety circuit ever be disabled.
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
The dryer must never be operated with any of the back guards, outer tops, or service
panels removed. PERSONALINJURYOR FIRE COULD RESULT.
WARNING
DRYER MUST NEVER BE OPERATED WITHOUTTHE LINT FILTER/SCREEN IN
PLACE, EVEN IFAN EXTERNALLINT COLLECTION SYSTEM IS USED.
IMPORTANT
PLEASE OBSERVEALLSAFETYPRECAUTIONS displayed on the equipment and/or
specified in the installation manual included with the dryer.
Dryer must not be installed or stored in an area where it will be exposed to water or weather.
The wiring diagram for the dryer is located in the front electrical control box area.
IMPORTANT
Dryer must be installed in a location/environment, which the ambient temperature
remains between 40° F (4.44° C) and 130° F (54.44° C).
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Con t en t s
SECTION I
SAFETY PRECAUTIONS .......................................................................................... 3
SECTION II
SPECIFICATIONS...................................................................................................... 5
SECTION III
INSTALLATION PROCEDURES.............................................................................. 7
A. Unpacking/Setting Up ................................................................................................................. 7
B. Location of the Dryer.................................................................................................................. 7
C. Dryer Enclosure Requirements .................................................................................................... 8
D. FreshAir Supply Requirements ................................................................................................... 9
E. Exhaust Requirements ............................................................................................................... 10
F. ElectricalInformation ................................................................................................................ 16
G. Gas Information ........................................................................................................................ 21
H. Preparation for Operation/Start-Up........................................................................................... 24
I. PreoperationalTests ................................................................................................................. 24
J. Preoperational Instructions ........................................................................................................ 26
K. Shutdown Instructions ............................................................................................................... 28
SECTION IV
SERVICE/PARTS INFORMATION ........................................................................ 29
A. Service ..................................................................................................................................... 29
B. Parts ........................................................................................................................................ 29
SECTION V
WARRANTYINFORMATION ................................................................................ 30
A. Returning Warranty Cards ......................................................................................................... 30
B. Warranty .................................................................................................................................. 30
C. ReturningWarranty Parts .......................................................................................................... 30
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VI
ROUTINE MAINTENANCE ................................................................................... 32
A. Cleaning ................................................................................................................................... 32
B. Adjustments ............................................................................................................................. 33
C. Lubrication ............................................................................................................................... 33
SECTION VII
DATA LABEL INFORMATION .............................................................................34
SECTION VIII
PROCEDURE FOR FUNCTIONAL CHECK
OF REPLACEMENT COMPONENTS................................................................36
SECTION IX
SENSOR ACTIVATED FIRE EXTINGUISHING (S.A.F.E.) SYSTEM ........... 39
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION I
SAFETY PRECAUTIONS
WARNING: For your safety, the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury, or loss of life.
WARNING: The dryer must never be operated with any of the back guards, outer tops, or
service panels removed. PERSONALINJURYOR FIRE COULD RESULT.
A. Keep dryer area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
B. Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the
user smells gas. The instructions should be posted in a prominent location.
C. WHAT TO DO IF YOU SMELL GAS:
1. DO NOT try to light any appliance.
2. DO NOT touch any electrical switch.
3. DO NOT use any phone in your building.
4. Clear the room, building, or area of ALL occupants.
5. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
6. If you cannot reach your gas supplier, call the fire department.
D. Installation and service must be performed by a qualified installer, service agency, or gas supplier.
E. Dryer(s) must be exhausted to the outdoors.
F. Although ADC produces a very versatile dryer, there are some articles that, due to fabric composition or
cleaning method, should not be dried in it.
WARNING: Dry only water washed fabrics. DO NOT dry articles spotted or washed in dry
cleaning solvents, a combustible detergent, or “all purpose” cleaner.
EXPLOSION COULD RESULT.
WARNING: DO NOT dry rags or articles coated or contaminated with gasoline, kerosene, oil, paint,
or wax.
EXPLOSION COULD RESULT.
WARNING: DO NOT dry mop heads. Contamination by wax or flammable solvents will create a
fire hazard.
113222-5
3
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or
similarly textured materials. Drying in a heated basket (tumbler) may damage
plastics or rubber and may be a fire hazard.
G. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust
ductwork, and inside the dryer. The frequency of inspection and cleaning can best be determined from
experience at each location.
WARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire
hazard.
H. For personal safety, the dryer must be electrically grounded in accordance with local codes and/or the
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE: Failure to electrically ground dryer properly will VOID THEWARRANTY.
I. UNDER NO CIRCUMSTANCES should the dryer door switch, lint door switch, or heat safety circuit
ever be disabled.
WARNING: PERSONALINJURYOR FIRE COULD RESULT should the dryer door switch,
lint door switch, or heat safety circuit ever be disabled.
J. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
K. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING: Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
CAUTION: Label ALL wires prior to disconnection when servicing controls. Wiring errors cause
improper and dangerous operation. Verify proper operation after servicing.
L. READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE
DRYER.
M. For safety, proper operation, and optimum performance, the dryer must not be operated with a load less
than sixty-six percent (66%), 13 lb (5.89 kg) of its rated capacity.
WARNING: YOU MUST DISCONNECTAND LOCK OUTTHE ELECTRIC SUPPLY
AND THE GAS SUPPLYBEFOREANYCOVERS OR GUARDSARE
REMOVED FROM THE MACHINE TOALLOWACCESS FOR CLEANING,
ADJUSTING, INSTALLATION, OR TESTINGOFANYEQUIPMENT PER
OSHA(Occupational Safety and HealthAdministration) STANDARDS.
IMPORTANT: Dryer must be installed in a location/environment, which the ambient
temperature remains between 40º F (4.44º C) and 130º F (54.44º C).
4
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION II
SPECIFICATIONS
9.07 kg
69.22 cm
60.96 cm
229.37 L
0.37 kW
MAXIMUM CAPACITY (DRY WEIGHT)
20 lb
27-1/4”
24”
TUMBLER DIAMETER
TUMBLER DEPTH
TUMBLER VOLUME
8.10 cu ft
1/2 hp
TUMBLER/DRIVE MOTOR
BLOWER/FAN MOTOR
DOOR OPENING (DIAMETER)
DOOR SILL HEIGHT
N / A
54.61 cm
71.91 cm
21-1/2”
28-1/3”
WATER CONNECTION*
DRYERS PER 20’/40’ CONTAINER
DRYERS PER 48’/53’ TRUCK
VOLTAGE AVAILABLE
3/4” F.N.P.T.
14 / 30
42 / 47
120-480V
426 lb
1,3ø 2,3,4w
50/60 Hz
193.23 kg
APPROXIMATE NET WEIGHT
APPROXIMATE SHIPPING WEIGHT
AIRFLOW
209.11 kg
11.33 cmm
9.44 cmm
461 lb
400 cfm
333 cfm
60,000 Btu/hr
6”
60 Hz
50 Hz
15,120 kcal/hr
15.24 cm
HEAT INPUT
EXHAUST CONNECTION (DIAMETER)
COMPRESSED AIR CONNECTION
COMPRESSED AIR VOLUME
INLET PIPE CONNECTION
N / A
N / A
1/2” M.N.P.T.
1,3ø 2,3,4w
VOLTAGE AVAILABLE
208-480V
426 lb
50/60 Hz
193.23 kg
APPROXIMATE NET WEIGHT
APPROXIMATE SHIPPING WEIGHT
209.11 kg
11.33 cmm
9.44 cmm
15.24 cm
461 lb
400 cfm
333 cfm
6”
60 Hz
50 Hz
AIRFLOW
EXHAUST CONNECTION (DIAMETER)
COMPRESSED AIR CONNECTION
COMPRESSED AIR VOLUME
OVEN SIZE
N / A
N / A
kW
18
20
24
Btu/hr
kcal/hr
15,500
17,200
20,600
61,400
68,200
81,900
VOLTAGE AVAILABLE
APPROXIMATE NET WEIGHT
APPROXIMATE SHIPPING WEIGHT
AIRFLOW
60 Hz
50 Hz
STEAM CONSUMPTION
OPERATING STEAM PRESSURE
N / A
EXHAUST CONNECTION (DIAMETER)
COMPRESSED AIR CONNECTION
COMPRESSED AIR VOLUME
BOILER HORSEPOWER (NORMAL LOAD)
SUPPLY CONNECTION
RETURN CONNECTION
Shaded areas are stated in metric equivalents
10/04/06
* Water supply must be 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) for fire suppression system to operate properly.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
113222-5
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
6
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION III
INSTALLATION PROCEDURES
Installation should be performed by competent technicians in accordance with local and state codes. In the
absence of these codes, the installation must conform to applicableAmerican National Standards:ANSI.Z223.1-
LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical
Code) or in Canada, the installation must conform to Canadian Standards: CAN/CGA-B149.1-M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation
and Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION (for
Electrical Connections).
A. UNPACKING/SETTING UP
Remove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer.
The dryer can be moved to its final location while still attached to the skid or with the skid removed. To unskid the
dryer, locate and remove the four (4) bolts securing the base of the dryer to the wooden skid. Two (2) are at the
rear base (remove the back panel for access), and two (2) are located in the bottom of the lint chamber. To
remove the two (2) bolts located in the lint chamber area, remove the lint door. Once the bolts are removed, slide
the dryer off the skid.
With the skid removed, to make it easier to slide the dryer into its final position, slightly lower ALL four (4)
leveling legs, so that the dryer will slide on the legs instead of the base frame. The dryer is equipped with four (4)
leveling legs, one (1) at each corner of the dryer base. Two (2) are located at the rear of the dryer base, and two
(2) are located in the lint chamber.
To increase bearing life and improve efficiency, the dryer should be tilted slightly to the rear.
B. LOCATION OF THE DRYER
Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such
codes or ordinances the location must conform with the National Fuel Gas CodeANSI.Z223.1 LATEST EDITION,
or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General Installation and Gas Plumbing).
1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be
removed from the floor area that the dryer is to rest on.
IMPORTANT: “The dryer must be installed on noncombustible floors only.”
2. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.
3. The dryer is for use in noncombustible locations.
4. Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply
Requirements in Section D).
5. Clearance provisions must be made from noncombustible construction as noted in this manual (refer to
Dryer Enclosure Requirements in Section C).
113222-5
7
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Provisions must be made for adequate clearances for servicing and for operation as noted in this manual
(refer to Dryer Enclosure Requirements in Section C).
7. Dryer must be exhausted to the outdoors in an area where correct exhaust venting can be achieved as
noted in this manual (refer to Exhaust Requirements in Section E).
8. Dryer must be located in an area where correct exhaust venting can be achieved as noted in this manual
(refer to Exhaust Requirements in Section E).
IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will be necessary.
9. The dryer must be installed with a proper exhaust duct connection to the outside.
10. The dryer must be installed with provisions for adequate combustion and make-up air supply.
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint buildup.
IMPORTANT: Dryer must be installed in a location/environment, which the ambient
temperature remains between 40º F (4.44º C) and 130º F (54.44º C).
C. DRYER ENCLOSURE REQUIREMENTS
Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of
12-inches (30.48 cm), 18-inches (45.72 cm) or more is recommended for ease of installation, maintenance, and
service, above the dryer outer top, except along the front of the dryer, which may be closed in if desired. The
clearance between the bulkhead header and the dryer must be a minimum of 4-inches (10.16 cm) and must not
extend more than 4-inches (10.16 cm) to the rear of the front.
NOTE: Allowances must be made for opening the control door.
IMPORTANT: If the dryer is installed in a closet type enclosure there must be no other fuel burning
appliance installed in the same closet.
Dryers may be positioned sidewall to sidewall. However, a 1/16” (1.5875 mm) minimum allowance must be
made for opening and closing of the control door and the lint door. It is suggested that the dryer be positioned
about 2 feet (0.61 meters) away from the nearest obstruction for ease of installation, maintenance, and service
(to be measured from the back guard). Refer to the illustration below for details.
X = 12-inch (30.48 cm) minimum, 24-inches (60.96 cm) is suggested for ease of maintenance.
8
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: Air considerations are important for proper and efficient operation.
D. FRESH AIR SUPPLY REQUIREMENTS
Air supply (make-up air) must be given careful consideration to ensure proper performance of each dryer. An
unrestricted source of air is necessary for each dryer. An airflow of 400 cfm (cubic feet per minute)
(11.3 cmm [cubic meters per minutes]) must be supplied to each gas dryer. As a general rule, an unrestricted air
entrance from the outdoors (atmosphere) of a minimum of 1 square foot (0.093 square meters) is required for
each dryer. If registers or louvers are installed over the openings, then the area must be increased. It is not
necessary to have separate make-up air openings for each dryer. Common make-up air openings are acceptable.
However, they must be set up in such a manner that the make-up air is distributed equally to the dryers. The
dryer must be installed with provisions for adequate combustion and make-up air supply.
EXAMPLE: For a bank of eight (8) dryers, two (2) unrestricted openings measuring 2 feet by 2 feet
(0.61 meters by 0.61 meters) are acceptable.
IMPORTANT: Make-up air openings should not be located in an area directly near where exhaust
vents exit the building.
Allowances must be made for remote or constricting passageways or where dryers are located at excessive
altitudes or predominantly low pressure areas.
IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes.
Make-up air that is contaminated by dry cleaning solvent fumes will result in
irreparable damage to the motors and other dryer components.
NOTE: Component failure due to dry cleaning solvent fumes willVOIDTHEWARRANTY.
113222-5
9
Download from Www.Somanuals.com. All Manuals Search And Download.
E. EXHAUST REQUIREMENTS
Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will
create excessive back pressure, which results in slow drying, increased use of energy, overheating of the dryer,
and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-limit thermostats.
(Refer to the illustrations on page 11 and page 12 for details.) The dryer must be installed with a proper exhaust
duct connection to the outside.
CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors.
CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCTWORK CAN
CREATE APOTENTIAL FIRE HAZARD.
When possible, it is desirable to provide a separate exhaust air duct for each dryer. The duct should go as directly
as possible to the outside air. Avoid sharp 90º right-angle turns in ducting; use 30º or 45º angles instead. The
radius of the elbows should preferably be 1-1/2 times the diameter of the duct. To protect the outside end of
the duct from the weather, it may be bent downwards as indicated on page 11 and page 12. Leave at least twice
the diameter of the duct as clearance between the duct opening and the nearest obstruction. If the exhaust duct
goes through the roof, it may be protected from the weather by using a 180º turn to point the opening down. Allow
at least twice the diameter of the duct as clearance from the nearest obstruction.
DO NOT use screens, louvers, or caps on the outside opening of the exhaust ductwork. The ducting should be
smooth inside with no projections from sheet metal screws or other obstructions, which will collect lint. Additionally,
inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and
cleaning.
Inadequate exhaust facilities may cause high temperature limit switches or airflow switches to shut off the
dryers. DO NOT disable the switches, which are provided for your safety. Instead, investigate the exhaust
ducting. Any obstruction or air friction due to numerous elbows/fittings in the ducting will slow the passage of air
through the system with resulting inefficiency and potential fire hazard.
IMPORTANT: Exhaust back pressure measured by a manometer at the dryer’s exhaust duct area
must be no less than 0 and must not exceed 0.3 inches (0.74 mb) of water column
(W.C.).
NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible
materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around).
The duct must be centered within this opening.
IMPORTANT: The dryer exhaust duct must not be connected to any gas vent, chimney, wall, ceiling,
or concealing space of a building.
IMPORTANT: It is recommended that exhaust or booster fans not be used in the exhaust ductwork
system.
NOTE: As per the National Fuel Gas Code, “Exhaust ducts for type 2 clothes dryers shall be
constructed of sheet metal or other noncombustible material. Such ducts shall be equivalent in
strength and corrosion resistance to ducts made of galvanized sheet steel not less than 26
gauge (0.0195-inches [0.50 mm]) thick.”
10
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
SINGLE DRYER VENTING
IMPORTANT: A minimum exhaust duct size of 6-inches (15.24 cm) must be used.
For a 6-inch (15.24 cm) horizontal run where a maximum of one (1) elbow is used (refer to the illustration
below), the ductwork from the dryer outlet must not exceed 8 feet (2.44 meters).
If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the
cross-sectional area of the ductwork must be increased in proportion to the number of elbows or duct run added.
IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only be
increased to an extent. When the ductwork approaches the maximum limits noted in
this manual, a professional heating, ventilating, and air-conditioning (HVAC) firm
should be consulted for proper venting information.
When single 6-inch (15.24 cm) venting is used, for a horizontal run, the ductwork from the dryer to the outside
outlet cannot exceed 8 feet (2.44 meters) in total length. This calculation of 8 feet (2.44 meters) compensates
or allows for the use of a maximum of one (1) elbow (which is the outside outlet protection). Refer to the
illustration above.
113222-5
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SINGLE DRYER VENTING
IMPORTANT: A minimum exhaust duct size of 8-inches (20.32 cm) must be used.
For an 8-inch (20.32 cm) horizontal run where a maximum of one (1) elbow is used (refer to the illustration
below), the ductwork from the dryer outlet must not exceed 40 feet (12.2 meters).
If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the
cross-sectional area of the ductwork must be increased in proportion to the number of elbows or duct run added.
IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only be
increased to an extent. When the ductwork approaches the maximum limits noted in
this manual, a professional heating, ventilating, and air-conditioning (HVAC) firm
should be consulted for proper venting information.
When single 8-inch (20.32 cm) venting is used, for a horizontal run, the ductwork from the dryer to the outside
outlet cannot exceed 40 feet (12.2 meters) in total length. This calculation of 40 feet (12.2 meters) compensates
or allows for the use of a maximum of one (1) elbow (which is the outside outlet protection). Refer to the
illustration above.
12
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
When single 8-inch (20.32 cm) vertical venting is used (refer to the illustration below), the ductwork from the
dryer to the outside outlet cannot exceed 35 feet (10.67 meters) in total length. This calculation of 35 feet (10.67
meters) compensates or allows for the use of a maximum of three (3) elbows including the 180º (turned downward)
outside outlet.
113222-5
13
Download from Www.Somanuals.com. All Manuals Search And Download.
14
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only be
increased to an extent. When the ductwork approaches the maximum limits as noted
in this manual, a professional heating, ventilating, and air-conditioning (HVAC)
firm should be consulted for proper venting information.
IMPORTANTVENTINGREMINDERS
1. Ductwork size and installation should be done by a qualified professional.
2. The dryer must be exhausted to the outdoors.
3. The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, or concealing space of
a building.
4. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible.
5. Avoid 90º turns, use 30º or 45º turns instead.
6. The inside of the ductwork should be as smooth as possible with no projections from sheet metal screws.
7. ALL ducts should be taped to prevent moisture and lint from escaping into the building.
8. Inspection or clean out doors should be installed throughout strategic points in the ductwork for periodic
inspection and cleaning.
9. Whenever the ductwork passes through combustible materials, the opening must be 2-inches (5.08 cm)
larger than the duct (all the way around). The duct must be centered within this opening.
10. The outside of the ductwork must be protected from the weather. A 90º elbow must be used for a
horizontal run and when vertically through a roof by using a 180º turn to point the opening downward. The
distance between the exhaust duct and the nearest obstruction (i.e., roof or ground) must be twice the
diameter of the duct.
11. DO NOT use screens, louvers, or caps on the outside opening of the exhaust ductwork.
12. Exhaust back pressure measured by a manometer at the dryer’s exhaust duct area must be no less than 0
and must not exceed 0.3 inches (0.74 mb) of water column (W.C.).
IMPORTANT: It is recommended that exhaust or booster fans not be used in the exhaust ductwork
system.
113222-5
15
Download from Www.Somanuals.com. All Manuals Search And Download.
F. ELECTRICAL INFORMATION
1. Electrical Requirements
ALL electrical connections must be made by a properly licensed and competent electrician. This
is to ensure that the electrical installation is adequate and conforms to local and state regulations or codes.
In the absence of such codes, ALL electrical connections, materials, and workmanship must conform to
the applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in
Canada, the Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements
stipulated in this manual can result in personal injury or component failure.
NOTE: Component failure due to improper installation will VOID THE WARRANTY.
Each dryer should be connected to an independently protected branch circuit. The dryer must be connected
with copper wire only. DO NOT use aluminum wire, which could cause a fire hazard. The copper
conductor wire/cable must be of proper ampacity and insulation in accordance with electric codes for making
ALL service connections.
NOTE: The use of aluminum wire will VOID THE WARRANTY.
IMPORTANT: A separate protected circuit must be provided to each dryer.
NOTE: An individual ground circuit must be provided to each dryer, do not daisy chain.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label. In
the case of 208 VAC or 240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VACAND 240 VACARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: Component failure due to improper voltage application will VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
16
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Electrical Service Specifications
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact
the factory.
a. Gas Models Only
Gas
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
NOTES: A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) motor curve type
ONLY. For others, calculate/verify correct breaker size according to
appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
APPROX.
AMP DRAW
SERVICE
VOLTAGE
WIRE
SERVICE
CIRCUIT
BREAKER
PHASE
60 Hz
8.7
5.2
4.8
3.0
3.2
—
50 Hz
120
208
240
208
240
380-400
416
460/480
1ø
1ø
1ø
3ø
3ø
3ø
3ø
3ø
2
2
2
3
3
4*
4*
3
—
—
15
15
15
15
15
15
15
15
5.8
—
3.6
2.2
2.3
—
—
2.1
* 3-Wire is available.
6/3/08
b. Electric Models Only
ALL electrically heated dryers must be connected to the electric service shown on the dryer’s data label.
The connecting wires must be properly sized to handle the rated current.
Electric
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
NOTES: A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse
value, by applying either local and/or National Electrical Codes to
listed appliance amp draw data.
B. Circuit breakers are thermal-magnetic (industrial) type ONLY. For others,
calculate/verify correct breaker size according to appliance amp draw
rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
APPROX.
SERVICE
VOLTAGE
WIRE
SERVICE
CIRCUIT
BREAKER
PHASE
AMP DRAW
60 Hz
50 Hz
18 kW
208
240
240
208
240
1ø
1ø
1ø
3ø
3ø
2
2
2
3
3
92
—
80
55
48
—
81
—
—
—
125
110
100
70
60
20 kW
24 kW
208
240
1ø
1ø
2
2
101
88
—
—
150
110
208
240
416
460
480
3ø
3ø
3ø
3ø
3ø
3
3
4*
3
72
63
—
32
31
—
—
39
—
—
90
80
50
40
40
3
* 3-Wire is available.
6/3/08
113222-5
17
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Grounding
A ground (earth) connection must be provided and installed in accordance with state and local codes. In the
absence of these codes, grounding must conform to applicable requirements of the National Electrical Code
ANSI/NFPANO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada
Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION. The ground
connection may be to a proven earth ground at the location service panel.
For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be
connected from the ground connection of the dryer to a grounded cold water pipe. DO NOT ground to a gas
pipe or hot water pipe. The grounded cold water pipe must have metal-to-metal connection ALL the way to
the electrical ground. If there are any nonmetallic interruptions, such as, a meter, pump, plastic, rubber, or
other insulating connectors, they must be jumped out with no. 4 copper wire and securely clamped to bare
metal at both ends.
IMPORTANT: For personal safety and proper operation, the dryer must be grounded.
Provisions are made for ground connection in each dryer at the electrical service connection area.
4. Electrical Connections
A wiring diagram is located inside the control box for connection data.
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord/pigtail
(wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker
panel. In both cases, a strain relief must be installed where the wiring enters the dryer.
a. Gas Models Only
IMPORTANT: A separate protected circuit must be provided to each dryer.
1) Single-Phase (1ø) Wiring Connections/Hookup
The electrical input connections on ALL single-phase (1ø)
gas dryers are made into the rear service box located at the
upper left area of the dryer.
18
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Single-Phase Electrical Lead Connections
White or Red
Black
+
Positive
Green
+
Ground
+
Neutral
or L2
FOR 110VAPPLICATIONS
FOR 208-240VAPPLICATIONS
A ground lug is provided in the rear electrical box to connect your service ground.
113222-5
19
Download from Www.Somanuals.com. All Manuals Search And Download.
2) 3-Phase (3ø) Wiring Connections/Hookup
The electrical connections on ALL 3-phase (3ø) gas dryers are made into the rear service box
located at the upper left area of the dryer. The electrical connections are made at the power
distribution block located in the service box. The ground connection is made to the copper lug, also
provided in this box. To gain access, the service box cover must be removed.
The neutral will only be used on 4-wire service. This is typical for 380-416V, 50 Hz.
b. Electrically Heated Models Only
The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and
sometimes neutral) and ground. Single-phase (1ø) power for the control circuit and for any
single-phase (1ø) motors (if present) is done internally to the dryer by the factory at the oven contactor.
No single-phase (1ø) input connection is required on a 3-phase (3ø) dryer.
CAUTION: The dryer must be grounded. A ground lug has been provided for this purpose.
Input connection wiring must be sized properly to
handle the dryer’s current draw. This information is
printed on the dryer’s data label.
The electrical input connections are made at the electric
oven contactor located inside the assembly at the rear
center upper section of the dryer. The ground
connection is made to a copper lug also provided in
this area. To gain access, remove oven rear service
cover.
IMPORTANT: A strain relief must be used where
the input wiring enters the oven
assembly.
20
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
G. GAS INFORMATION
It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas
plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such
codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of
the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes
CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST
EDITION.
IMPORTANT: Failure to comply with these codes or ordinances, and/or the requirements stipulated
in this manual, can result in personal injury and improper operation of the dryer.
Each dryer must have its own manual shutoff valve to provide isolation of the dryer from the gas supply.
The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The dryer must be isolated from
the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas
supply system at test pressures equal to or less than 1/2 psig (3.5 kPa).
IMPORTANT: Failure to isolate or disconnect the dryer from supply as noted can cause irreparable
damage to the gas valve VOIDING THE WARRANTY.
WARNING: FIRE OR EXPLOSION COULD RESULT due to failure of isolating or
disconnecting gas supply as noted.
1. Gas Supply
The gas dryer installation must meet the American National Standard...National Fuel Gas Code ANSI
Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1 M91 (Natural
Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION, as well as local codes and ordinances
and must be done by a qualified professional.
NOTE: Undersized gas piping will result in ignition problems, slow drying, increased use of energy, and
can create a safety hazard.
The dryer must be connected to the type of heat/gas indicated on the dryer data label. If this information
does not agree with the type of gas available, DO NOT operate the dryer. Contact the reseller who sold
the dryer or contact the ADC factory.
IMPORTANT: Any burner changes or conversions must be made by a qualified professional.
The input ratings shown on the dryer data label are for elevations up to 2,000 feet (610 meters), unless
elevation requirements of over 2,000 feet (610 meters) were specified at the time the dryer order was
placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet
(610 meters) is made by changing each burner orifice. If this conversion is necessary, contact the reseller
who sold the dryer or contact the ADC factory.
IMPORTANT: THIS GAS DRYER IS NOT PROVIDED WITHAN INTERNALGAS SUPPLY
SHUTOFFANDAN EXTERNALGAS SUPPLYSHUTOFF MUST BE
PROVIDED.
113222-5
21
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Technical Gas Data
a. Gas Specifications
TYPE OF GAS
NATURAL
LIQUID PROPANE
8.7 mb
26.1 mb
27.4 mb
Manifold Pressure*
In-Line Pressure
3.5 inches W.C.
10.5 inches W.C.
11.0 inches W.C.
14.92 - 29.9 mb
6.0 - 12.0 inches W.C.
Shaded areas are stated in metric equivalents
* Measured at outlet side of gas valve pressure tap when gas valve is on.
b. Gas Connections:
Inlet connection---- 1/2” N.P.T.
Inlet supply size---- 1/2” Pipe (minimum)
Btu/hr input--------- 60,000 (15,120 kcal/hr)
1) Natural Gas
Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure
must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches
(29.9 mb) water column (W.C.) pressure.
2) Liquid Propane (L.P.) Gas
Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so
that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas
valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator
or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source
(L.P. tank) or an external regulator must be added to each dryer.
TYPE OF GAS
Liquid Propane
Conversion Kit
Part Number
Natural
Liquid Propane
kcal/hr
Rating
Btu/hr
Rating
Part
Part
Number
Qty. D.M.S.*
Qty. D.M.S.*
#52
Number
15,120
60,000
2
#37
140815
2
140800
874058
Shaded area is stated in metric equivalent
* Drill Measurement Size (D.M.S.) equivalents are as follows:
Natural Gas ..................... #37
Liquid Propane Gas ....... #52
=
=
0.1040” (2.6416 mm).
0.0635” (1.6129 mm).
22
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Piping Connections
ALL components/materials must conform to National Fuel Gas Code SpecificationsANSI Z223.1-LATEST
EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane
[L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and
ordinances and must be done by a qualified professional. It is important that gas pressure regulators meet
applicable pressure requirements, and that gas meters be rated for the total amount of ALL the appliance
Btu being supplied.
The dryer is provided with a 1/2” N.P.T. inlet pipe connection located at the right side of the base of the
dryer. The minimum pipe size (supply line) to the dryer is 1/2” pipe. For ease in servicing, the gas supply
line of each dryer must have its own shutoff valve.
IMPORTANT: The gas supply line to each dryer must be a minimum of 1/2-inch (12.7 mm).
DO NOT REDUCE THIS PIPE SIZE REQUIREMENT.
The size of the main gas supply line (header) will vary depending on the distance this line travels from the
gas meter or, in the case of L.P. gas, the supply tank, other gas-operated appliances on the same line, etc.
Specific information regarding supply line size should be determined by the gas supplier.
NOTE: Undersized gas supply piping can create a low or inconsistent pressure, which will result in
erratic operation of the burner ignition system.
113222-5
23
Download from Www.Somanuals.com. All Manuals Search And Download.
H. PREPARATION FOR OPERATION/START-UP
The following items should be checked before attempting to operate the dryer:
1. Read ALL “CAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label.
3. GAS MODELS - check to ensure that the dryer is connected to the type of heat/gas indicated on the dryer
data label.
4. The sail switch damper assembly was installed and adjusted at the factory prior to shipping. However, each
sail switch adjustment must be checked to ensure that this important safety control is functioning.
5. Check bolts, nuts, screws, terminals, and fittings for tightness.
6. GAS MODELS - be sure that ALL gas shutoff valves are in the open position.
7. Be sure ALL back guard panels and service box covers have been replaced.
8. Check the lint door to ensure that it is closed and secured in place.
IMPORTANT: If during installation the lint door safety chain was disconnected, it must be
reconnected or personal injury may result.
9. Rotate the basket (tumbler) by hand to be sure it moves freely.
I. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.
1. Turn on electric power to the dryer.
2. Refer to the Operating Instructions for starting your particular model dryer.
3. Gas Dryers
a. When a gas dryer is first started (during initial start-up), it has a tendency not to ignite on the first ignition
attempt. This is because the gas supply piping is filled with air, so it may take a few minutes for the air
to be purged from the lines.
NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open.
24
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: Gas model dryers are equipped with an ignition system, which has internal diagnostics. If
ignition is not established after one (1) time, the heat circuit in the ignition module will attempt
two (2) more ignitions (total of three [3] ignition attempts). If there is no flame after the third
ignition attempt, the module will lock out until it is manually reset. To reset the ignition system,
open and close the main door and restart the dryer.
b. A gas pressure test should be taken at the gas valve pressure tap of each dryer to ensure that the water
column (W.C.) pressure is correct and consistent.
NOTE: Water column pressure requirements (measured at the pressure tap of the gas valve body):
Natural Gas----------------------- 3.5 inches (8.7 mb) water column.
Liquid Propane (L.P.) Gas ------ 10.5 inches (26.1 mb) water column.
IMPORTANT: There is no regulator provided in an L.P. dryer. The water column pressure must be
regulated at the source (L.P. tank) or an external regulator must be added to each
dryer.
4. Make a complete operational check of ALL safety related circuits:
a. Door Switch(es)
b. Hi-Limit Thermostats
c. Cycling Thermostats
d. Sail Switch
NOTE: The sail switch can be checked for proper operation by opening the lint door while the heating
circuit (gas burner/electric oven) is active (on). The heating unit should shut off within a few
seconds. If not, make necessary adjustments to the sail switch.
5. Make a complete operational check of ALL operating controls.
NOTE: If computer program changes are required, refer to the computer programming section of the
manual supplied with the dryer.
6. The dryer should be operated through one (1) complete cycle to ensure that no further adjustments are
necessary and that ALL components are functioning properly.
BASKET (TUMBLER) COATING
The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material
with a solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove
this coating.
7. Check the electric service phase sequence (3-phase [3ø] models only). While the dryer is operating, check
to see if the blower wheel (impellor/fan) is rotating in the proper direction. Looking from the front, the
blower wheel (impellor/fan) should spin in the clockwise (CW) direction. If it is, the phasing is correct. If
the phasing is incorrect, reverse the two (2) leads at connections L1, L2, or L3 of the power supply to the
dryer.
113222-5
25
Download from Www.Somanuals.com. All Manuals Search And Download.
J. PREOPERATIONAL INSTRUCTIONS
COIN MODELS
1. Microprocessor Controller (Computer)
a. When the microprocessor controller (computer) is in the ready state, the liquid crystal display (L.C.D.)
screen will display “Ready, Insert $XX.XX (amount) to Start”.
b. Insert coin(s). Once the correct “Amount to Start” has been inserted, the L.C.D. will display “Select
Temperature”.
c. Select temperature by pressing “HI,” “MED,” or “LO.” The cycle will start and the L.C.D. will display
the Dry Cycle selected and the remaining time.
d. The dryer will continue through the drying and cooling cycles, until the vended time has expired.
NOTE: To stop dryer, open main door or press the “PAUSE” key. Continuation of the cycle will
resume only after the door has been closed and any of the three (3) temperature selection is
pressed.
e. Upon completion of the drying and cooling cycles, the tone (buzzer) will sound and the dryer will go into
theAnti-Wrinkle Mode for 99 minutes, or until the main door has been opened.
IMPORTANT: For more detailed information regarding the microprocessor controller (computer) on
your dryer, refer to the microprocessor user’s manual included with the dryer.
2. Mechanical Drop/Rotary Coin Meter or Slide Coin Meter
a. Insert coin and turn knob (rotary type meter), or for slide meter unit, push in coin chute.
b. Select Temperature.
c. Push the “Start” button.
d. To stop dryer, open the main door.
26
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
NON-COIN MODELS
1. The light emitting diode (L.E.D.) display reads “READY” (no cycle in progress).
2. Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., key “D”).
NOTE: “0-40” WILLREQUIRE THE “START/ENTER”
l
KEYTO BE PRESSEDAFTER THE
NUMBER IS SELECTED IN ORDER TOACCEPTTHE SELECTIONAND START
DRYING.
3. The dryer will then start. (I.E., blower, basket [tumbler], and heat.)
4. The L.E.D. display will read MANUAL DRYING CYCLE D, 00:00 MIN REMAIN.
NOTE: Press and hold the “UPARROW” to view the basket (tumbler) temperature at any time.
NOTE: The dryer can be stopped at any time by pressing the “STOP/CLEAR” key, at this time
O
the dryer will go into a cycle pause. If the “STOP/CLEAR” key is pressed again at
O
this point, the cycle that was in progress will be cancelled and returned to the “READY”
state.
NOTE: Press and hold the “DOWNARROW” to view the basket (tumbler) RPM.
5. When the programmed drying time has expired, the Phase 7 non-coin microprocessor controller (computer)
will proceed into the Cool Down Cycle.
6. Once the Cool Down Cycle begins at the end of the heat cycle, the L.E.D. display will read COOL DOWN
TEMP ___/___ MINUTES REMAINING. At the end of the heat cycle, the dryer will shut off the heat and
continue the fan and basket (tumbler) until the Cool Down Time or temperature is reached.
IMPORTANT: For more detailed information regarding the microprocessor controller (computer) on
your dryer, refer to the microprocessor user’s manual included with the dryer.
DUAL TIMER DRYERS
1. Turn drying timer knob for a time of 20 minutes.
2. Select “High Temp.”
3. Push “Push to Start” button.
4. To stop dryer, open the main door.
Spin and dwell (stop) times are adjustable at the reversing timer.
113222-5
27
Download from Www.Somanuals.com. All Manuals Search And Download.
REVERSING TIMER SPIN/DWELLADJUSTMENTS
Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear
area of the dryer.
Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches located
on the electronic timer (as noted in the illustration below).
TIMING LEGEND
SPIN TIME
Adjustment Position Number
Time in Seconds*
1
2
3
4
5
30
60
90
120 150
DWELL (STOP) TIME
Adjustment Position Number
Time in Seconds*
1
5
2
3
4
5
6.3
7.6
8.9 10.2
* Values shown are +/- 1-second.
K. SHUTDOWN INSTRUCTIONS
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the gas supply (for gas models only):
a. SHUT OFF external gas supply shutoff valve.
b. SHUT OFF internal gas supply shutoff valve located in the gas valve burner area.
28
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION IV
SERVICE/PARTS INFORMATION
A. SERVICE
Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is
required, contact the reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted
or is unknown, contact the ADC Service Department for a reseller in your area.
NOTE: When contacting the ADC Service Department, be sure to give them the correct model
number and serial number so that your inquiry is handled in an expeditious manner.
B. PARTS
Replacement parts should be purchased from the reseller from whom the ADC equipment was purchased. If
the reseller cannot be contacted or is unknown, contact the ADC Parts Department for a reseller in your area.
Parts may also be purchased directly from the factory by calling the ADC Parts Department at (508) 678-9000
or you may FAX in your order at (508) 678-9447.
NOTE: When ordering replacement parts from the ADC reseller or the ADC factory be sure to give
them the correct model number and serial number so that your parts order can be
processed in an expeditious manner.
113222-5
29
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION V
WARRANTY INFORMATION
A. RETURNING WARRANTY CARDS
Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door
glass. These warranty cards are intended to serve the customer where we record the individual installation date
and warranty information to better serve you should you file a warranty claim.
If a warranty card did not come with your dryer, contact the ADC Warranty Department or the ADC Service
Department at (508) 678-9000.
IMPORTANT: Aseparate warranty card must be completed and returned for each individual dryer.
NOTE: Be sure to include the installation date when returning the warranty card(s).
B. WARRANTY
For a copy of the ADC commercial warranty covering your particular dryer(s), contact the ADC reseller from
whom you purchased the equipment and request a dryer warranty form. If the reseller cannot be contacted or
is unknown, warranty information can be obtained from the factory by contacting the ADC Warranty Department
at (508) 678-9000.
NOTE: Whenever contacting the ADC factory for warranty information, be sure to have the dryer’s
model number and serial number available so that your inquiry can be handled in an
expeditious manner.
C. RETURNING WARRANTY PARTS
ALL dryer or parts warranty claims or inquiries should be addressed to the ADC Warranty Parts Department. To
expedite processing, the following procedures must be followed:
1. No parts are to be returned to ADC without prior written authorization (“Return Material Authorization”
[R.M.A.]) from the factory.
NOTE: An R.M.A. is valid for only thirty (30) days from date of issue.
The R.M.A. issued by the factory, as well as any other correspondence pertaining to the returned part(s),
must be included inside the package with the failed merchandise.
30
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Each part must be tagged with the following information:
a. Model number and serial number of the dryer from which part was removed.
b. Nature of failure (be specific).
c. Date of dryer installation.
d. Date of part failure.
e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund.
NOTE: If a part is marked for a credit or a refund, the invoice number covering the purchase of the
replacement part must be provided.
NOTE: Warranty tags (ADC P/N 450064) are available at “no charge” from ADC upon request.
3. The company returning the part(s) must clearly note the complete company name and address on the
outside of the package.
4. ALL returns must be properly packaged to ensure that they are not damaged in transit. Damage claims are
the responsibility of the shipper.
IMPORTANT: No replacements, credits, or refunds will be issued for merchandise damaged in
transit.
5. ALL returns should be shipped to the ADC factory in such a manner that they are insured and a proof of
delivery can be obtained by the sender.
6. Shipping charges are not the responsibility of ADC. ALL returns should be “prepaid” to the
factory. Any “C.O.D.” or “COLLECT” returns will not be accepted.
IMPORTANT: No replacements, credits, or refunds will be issued if the claim cannot be processed
due to insufficient information. The party filing the claim will be notified in writing,
either by “FAX” or “CERTIFIED MAIL- Return Receipt Requested,” as to the
information necessary to process claim. If reply is not received by the ADC
Warranty Department within thirty (30) days from the FAX/letter date, then no
replacements, credits, or refunds will be issued, and the merchandise will be
discarded.
113222-5
31
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VI
ROUTINE MAINTENANCE
A. CLEANING
A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from
various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be
determined from experience at each location. Maximum operating efficiency is dependent upon proper air
circulation. The accumulation of lint can restrict this airflow. If the guidelines in this section are met, an ADC
dryer will provide many years of efficient, trouble free, and most importantly, safe operation.
WARNING: LINT FROM MOST FABRICS IS HIGHLYCOMBUSTIBLE. THE
ACCUMULATION OFLINT CAN CREATEAPOTENTIALFIRE HAZARD.
WARNING: KEEPDRYERAREACLEARAND FREE FROM COMBUSTIBLE
MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORSAND
LIQUIDS.
NOTE: Suggested time intervals shown are for average usage, which is considered six (6) to eight (8)
operational (running) hours per day.
IMPORTANT: Dryer produces combustible lint and must be exhausted to the outdoors. Every 6
months, inspect the exhaust ducting and remove any lint buildup.
SUGGESTED CLEANING SCHEDULE
EVERY THIRD OR FOURTH LOAD
Clean the lint screen every third or fourth load. Aclogged lint screen will cause poor dryer performance. The lint
screen is located behind the lint door in the base of the dryer. Open the lint door, brush the lint off the lint screen,
and remove the lint. Inspect lint screen and replace if torn.
NOTE: The frequency of cleaning the lint screen can best be determined from experience at each
location.
WEEKLY
Clean lint accumulation from lint chamber, thermostat, and microprocessor temperature sensor (sensor bracket)
area.
WARNING: TOAVOID THE HAZARD OFELECTRICALSHOCK, DISCONTINUE
ELECTRICALSUPPLYTOTHE DRYER.
32
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
90 DAYS
1. Remove lint from around basket (tumbler), drive motors, and surrounding areas.
2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.
3. Clean any lint accumulation in and around both the blower and drive motor casing openings.
NOTE: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly.
EVERY 6 MONTHS
Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer’s internal
exhaust ducting.
NOTE: THEACCUMULATION OFLINT IN THE EXHAUST DUCTWORK CAN
CREATEAPOTENTIALFIRE HAZARD.
NOTE: DO NOT OBSTRUCT THE FLOW OF COMBUSTIONAND VENTILATIONAIR.
CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST
DUCTWORK. INSPECTAND REMOVEANYLINTACCUMULATION, WHICH
CAN CAUSE THE DAMPER TO BIND OR STICK.
NOTE: A back draft damper that is sticking partially closed can result in slow drying and shutdown of
heat circuit safety switches or thermostats.
NOTE: When cleaning the dryer cabinet(s), avoid using harsh abrasives. Aproduct intended for the
cleaning of appliances is recommended.
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, setscrews, grounding connections, and nonpermanent gas connections (unions, shutoff
valves, and orifices). Motor and drive belts should be examined. Cracked or seriously frayed belts should be
replaced. Tighten loose V-belts when necessary. Complete operational check of controls and valves. Complete
operational check of ALL safety devices (door switches, lint drawer switch, sail switch, burner and hi-limit
thermostats).
C. LUBRICATION
The motor bearings, idler bearings, and under normal/most conditions the basket (tumbler) bearings are permanently
lubricated. It is physically possible to relubricate the basket (tumbler) bearings if you choose to do so even though
this practice is not necessary. Use ShellAlvania #2 grease or its equivalent. The basket (tumbler) bearings used in
the dryer DO NOT have a grease fitting. Provisions are made in the bearing housing for the addition of a grease
fitting, which can be obtained elsewhere, or from ADC by ordering kit P/N 882159 (includes two [2] fittings).
113222-5
33
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VII
DATA LABEL INFORMATION
When contacting American Dryer Corporation, certain information is required to ensure proper service/parts
information from ADC. This information is on the data label affixed to the left side panel area behind the top
control (access) door. When contacting ADC, please have the model number and serial number available.
34
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
THE DATA LABEL
1. MODEL NUMBER
The model number is an ADC number, which describes the size of the dryer and the
type of heat (gas, electric, or steam).
2. SERIAL NUMBER
The serial number allows ADC to gather information on your particular dryer.
3. MANUFACTURING CODE NUMBER
The manufacturing code number is a number issued by ADC, which describes ALL
possible options on your particular model.
4. TYPE OF HEAT
This describes the type of heat for your particular dryer: gas (either natural gas or
liquid propane [L.P.] gas), electric, or steam.
5. HEAT INPUT (FOR GAS DRYERS)
This describes the heat input in British thermal units per hour (Btu/hr).
6. ORIFICE SIZE (FOR GAS DRYERS)
Gives the number drill size used.
7. ELECTRIC SERVICE
This describes the electric service for your particular model.
8. GAS MANIFOLD PRESSURE (FOR GAS DRYERS)
This describes the manifold pressure taken at the gas valve tap.
113222-5
35
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION VIII
PROCEDURE FOR FUNCTIONAL CHECK
OF REPLACEMENT COMPONENTS
1. Microprocessor Controller (Computer) Board
a. Phase 7 Coin Models
1) Upon completing installation of the replacement microprocessor controller (computer) board,
reestablish power to the dryer.
2) Start the drying cycle by pressing any temperature selection keys (HI, PP, or LO).
3) Verify that the applicable indicator lights on the microprocessor controller (computer) board are lit.
(Refer to the illustration below.)
36
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
b. Phase 7 Non-Coin Models
1) Upon completing installation of the replacement microprocessor controller (computer) board,
reestablish power to the dryer.
2) Start the drying cycle by pressing any of the preset cycles in letters A-F.
3) Verify that the applicable indicator lights on the microprocessor controller (computer) board are lit.
(Refer to the illustration below.)
113222-5
37
Download from Www.Somanuals.com. All Manuals Search And Download.
2. For Models with Direct Spark Ignition (DSI) Module (Type I)
Theory of Operation:
Start the drying cycle. When the gas burner ignites within the
chosen trial for ignition time (6-seconds), the flame sensor detects
gas burner flame and signals the DSI module to keep the gas
valve open as long as there is a call for heat. The DSI module will
“LOCKOUT” if the gas burner flame is not sensed at the end of
the trial for ignition period. The trial for ignition period will be
repeated for a total of three (3) retries/trials (the initial try and two
[2] more retries/trials). If the flame is not sensed at the end of the
third retry/trial (inter-purge period of 30-seconds), the DSI module
will “LOCKOUT” (light emitting diode [L.E.D.] diagnostic
indicator flashes).
A steady L.E.D. indicator indicates normal operation.
No L.E.D. indicator indicates a power or an internal failure has occurred.
3. For Models with DSI Module (Type II)
Theory of Operation:
Start the drying cycle. When the gas burner ignites within the
chosen trial for ignition time (8-seconds), the flame sensor detects
gas burner flame and signals the DSI module to keep the gas
valve open as long as there is a call for heat. The DSI module will
“LOCKOUT” if the gas burner flame is not sensed at the end of
the trial for ignition period. The trial for ignition period will be
repeated for a total of three (3) retries/trials (the initial try and two
[2] more retries/trials). If the flame is not sensed at the end of the
third retry/trial (inter-purge period of 30-seconds), the DSI module
will “LOCKOUT” (a red L.E.D. diagnostic indicator will flash).
An unlit red L.E.D. diagnostic indicator indicates normal operation.
A lit green L.E.D. diagnostic indicator indicates dryer controller is calling for heat and that ALL interlocks
have been satisfied.
38
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
SECTION IX
SENSORACTIVATED
FIRE EXTINGUISHING (S.A.F.E.) SYSTEM
S.A.F.E. System In Action
The exclusive SensorActivated Fire Extinguishing (S.A.F.E.) System will extinguish
fires that may start in the drying basket (tumbler). A series of sensors positioned
throughout the basket (tumbler) and interfaced with the microprocessor will trigger the
S.A.F.E. system water jet(s) to quickly extinguish the flames. The water jet(s) remain
on for 2 minutes and will automatically activate again if a fire condition remains or
reignites. While the water jet(s) are activated, the basket (tumbler) will jog to move the
water throughout the load. The microprocessor will display that the system was activated
and will continue to display until the dryer is attended to.
We have tried to make this manual as complete as possible and hope you will find it
useful. ADC reserves the right to make changes from time to time, without notice or
obligation, in prices, specifications, colors, and material, and to change or discontinue
models.
113222-5
39
Download from Www.Somanuals.com. All Manuals Search And Download.
BEFORE YOU START!
CHECK LOCALCODESAND PERMITS
Call your local water company or the proper municipal authority for information regarding local codes.
IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified
professional to ensure that the plumbing installation is adequate and conforms to
local, state, and federal regulations or codes.
IMPORTANT: It is the installation or owners responsibility to see that the necessary or required
water, water pressure, pipe size, or connections are provided. Manufacturer
assumes no responsibility if the S.A.F.E. system is not connected, installed, or
maintained properly.
INSTALLATION
1. Requirements
The S.A.F.E. system must be supplied with a minimum water pipe size of 1/2” and be provided with 40 psi
+/- 20 psi (2.75 bar +/- 1.37 bar) of pressure. For use of optional manual bypass, a second source with the
same piping and pressure requirements is required.
Flexible 1/2 feeds must be provided to avoid damage to electric water solenoid valve by vibration.
IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard
plumbing connections WILLVOIDWARRANTY.
If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water lines from freezing.
WARNING: If the water in the supply line or water solenoid valve freezes, the S.A.F.E. system
will be INOPERATIVE!!
IMPORTANT: Appliance is to be connected to the water mains using a new hose set and the old
hose set should not be reused.
40
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Water Connections:
The water connection is made to the 3/4”-11.5 NH
hose adapter of the electric water solenoid valve,
located at the rear upper midsection of the dryer (refer
to the photo).
The water solenoid valve has a 3/8” M.P.T. connection
supplied with a 3/4”-11.5 NH hose adapter to provide
the minimum 1/2-inch supply (feed) line. Flexible
supply line/coupling must be used in an effort to avoid
damaging the electric water solenoid valve.
NOTE: The 3/4”-11.5 NH is a standard hose coupling screw thread. It is not to be confused with
3/4” N.P.T. The sealing of an NH connection is made with a washer opposed to the
mating threads of an N.P.T. assembly. The two (2) thread designs are not compatible.
IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard
plumbing connections WILLVOID WARRANTY. It is recommended that a filter
or strainer be installed in the water supply line.
Typical water supply:
113222-5
41
Download from Www.Somanuals.com. All Manuals Search And Download.
OPTIONALMANUALBYPASS
Provisions are made in the dryer S.A.F.E. system for the installation of an optional manual bypass. Depending on
the model dryer, the connections for the manual bypass are made at the “T” or “three way” fitting located in the
outlet supply side of the water solenoid valve. The use and connections of this manual bypass are at the option
or discretion of the owner.
The water connection for the manual bypass is made to the “T” or “three way” fitting, which has a 3/8” F.P.T.
and a coupling must be used to provide the minimum 1/2” supply (feed) line.
If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/freezing
temperatures, provisions must be made to protect these water lines from freezing.
WARNING: If the water in the supply line or water solenoid valve freezes, the S.A.F.E. system
will be INOPERATIVE!!
The manual ball cock shutoff valve must be located outside of the dryer at a distance from the dryer where it is
easily accessible.
3. Electrical Requirements
No independent external power source or supply connection is necessary. The 24 volt power to operate the
S.A.F.E. system is accomplished internally in the dryer (from the dryer controls).
WARNING: Electrical power must be provided to the dryer at ALL times. If the main electrical
power supply to the dryer is disconnected, the S.A.F.E. system is INOPERATIVE!!
42
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
S.A.F.E. System Theory of Operation
While the dryer is in an idle state, or 20-seconds after the heat turns off, the Phase 7 control monitors the
thermistor probe, located in the top of the basket (tumbler) chamber, and records the minimum temperature. If the
minimum recorded thermistor probe temperature is greater than 120° F (48° C) and the control detects a 50° rise
in temperature, this will be the trip point and the S.A.F.E. system routine will activate.
While a drying cycle is in process and the heat has turned on at least once, the Phase 7 control monitors the
exhaust temperature transducer. If the drying cycle temperature set point is set greater than 160° F (71° C) and the
control detects an exhaust temperature rise 25° F greater than set point, this will be the trip point and the S.A.F.E.
system routine will activate. If set point is below 160° F (71° C), the trip point will be 185° F (85° C).
Once the S.A.F.E. system routine is activated, the control will display “S.A.F.E. SYSTEM ACTIVATED” and
water will be injected into the basket (tumbler) chamber. Any time water is being injected into the basket
(tumbler), the basket (tumbler) drive will turn the load for 1-second every 15-seconds. This process will continue
for a minimum of 2 minutes. After the 2 minutes have elapsed, the control will check if the temperature remained
above trip point; if so, the water will remain on. The control will continue to check if the temperature is above trip
point every 30-seconds. If the water has been on for a constant 10 minutes, the water will be turned off,
regardless of the temperature, and the control will display “S.A.F.E. SYSTEM WAS ACTIVATED.” If the
temperature has dropped below trip point, the control will turn off the water prior to 10 minutes.
SYSTEM RESET
After the microprocessor determines that the situation is under control and shuts the water being injected into the
basket (tumbler) off, the microprocessor display will read “S.A.F.E. SYSTEM WASACTIVATED,” and the horn/
tone will sound until reset manually.
NON-COIN – To reset the microprocessor once the control displays “S.A.F.E. SYSTEM WAS ACTIVATED,”
press the red “STOP/CLEAR” key on the keyboard (touch pad).
COIN – To reset the microprocessor once the control displays “S.A.F.E. SYSTEM WAS ACTIVATED,” press
and hold the red “PAUSE” key for 3-seconds on the keyboard (touch pad).
113222-5
43
Download from Www.Somanuals.com. All Manuals Search And Download.
S.A.F.E. SYSTEM WATER VALVE CHECK
The operation of the water solenoid valve can be tested to ensure that the water supply system and valve are
functional. Before attempting a system check, be sure that ALL water supply shutoff valves to the dryer are in the
OPEN position; the dryer must be in the “READY” mode with no cycle loaded or in progress.
NON-COIN
1. Press and hold the red “STOP/CLEAR” key (while in “READY” mode and no cycle is in progress).
2. Press and hold the “A” key.
3. Water valve will open and water will be dispensed into basket (tumbler) area as long as both keys are held.
The Phase 7 non-coin microprocessor controller (computer) will prompt the user to perform a S.A.F.E. system
valve check at every 4000 hours to ensure proper functionality. At the 4000 hour mark, the control will wait for
end of the cycle and then will prompt the user to “PLEASE EMPTY TUMBLER, THEN PRESS THE
‘STOP/CLEAR’ AND ‘A’ KEYS TO TEST THE WATER VALVE.” When the ‘STOP/CLEAR’ and ‘A’ keys
are pressed, the control will activate the S.A.F.E. system water valve for 2-seconds, at which point the control
will prompt the user with the following message: “IF WATER DID NOT TURN ON, CALL FOR SERVICE.
THANK YOU.”
NOTE: The control will not let the user continue until the valve test has been completed.
COIN
While the control is in the program mode, press and hold the “PAUSE” key for 3-seconds to get into the valve test
mode. Valve test mode: The control will display “PRESSAND HOLD MEDIUM TO OPEN WATER VALVE”.
When the medium key is pressed, the control will activate the water output.
S.A.F.E. SYSTEM Diagnostics
NON-COIN – In the event that the Phase 7 non-coin microprocessor controller (computer) detects a fault in the
S.A.F.E. system, the control will display the message “S.A.F.E. SYSTEM DISABLED…READY.” To find out
why the S.A.F.E. system is disabling, press and hold the red “STOP/CLEAR” and green “START” keys. This
will cause the control to display a diagnostic message, as detailed in the “S.A.F.E. SYSTEM Diagnostics Messages”
section.
COIN – In the event that the Phase 7 microprocessor controller (computer) detects a fault in the S.A.F.E.
system, the control will display the message “S.A.F.E. SYSTEM DISABLED…READY, INSERT XX TO
START.” To find out the reason for the S.A.F.E. system disabling, press and hold the red “PAUSE” and
“LOW” keys. This will cause the control to display a diagnostic message, as detailed in the following section.
44
American Dryer Corp.
113222-5
Download from Www.Somanuals.com. All Manuals Search And Download.
S.A.F.E. SYSTEM DIAGNOSTICS MESSAGES
OPEN THERMISTOR PROBE – This message indicates that the S.A.F.E. system thermistor probe either is not
connected or is damaged. If this condition is detected, the Phase 7 non-coin control will immediately enter
S.A.F.E. SYSTEM DISABLED mode.
SHORTED THERMISTOR PROBE – This message indicates that the S.A.F.E. system thermistor probe is
damaged or the wiring is shorted. If this condition is detected, the Phase 7 non-coin control will immediately enter
S.A.F.E. SYSTEM DISABLED mode.
DISCONNECTED WATER VALVE – This message indicates that the water valve is open or that it is not
connected to the control. If this condition is detected, the Phase 7 non-coin control will continue to monitor the
condition for a period of 5 minutes before entering S.A.F.E. SYSTEM DISABLED mode. Once the condition is
corrected, the control will continue to monitor the condition for 1 minute before exiting S.A.F.E. SYSTEM
DISABLED mode.
SHORTED WATER VALVE – This message indicates that the water valve is shorted or that the wiring to the
valve is shorted. If this condition is detected, the Phase 7 non-coin control will continue to monitor the condition
for a period of 5 minutes before entering S.A.F.E. SYSTEM DISABLED mode. Once the condition is corrected,
the control will continue to monitor the condition for 1 minute before exiting S.A.F.E. SYSTEM DISABLED
mode.
WATER NOT CONNECTED – This indicates that there is no water pressure at the water valve. This will occur
if water is not connected to the dryer, or if there is low water pressure in the water line coming to the dryer. This
could also signify a defective pressure switch or defective wiring to the pressure switch. If this condition is
detected, the Phase 7 non-coin control will continue to monitor the condition for a period of 5 minutes before
entering S.A.F.E. SYSTEM DISABLED mode. Once the condition is corrected, the control will continue to
monitor the condition for 1 minute before exiting S.A.F.E. SYSTEM DISABLED mode.
STARTING A CYCLE
WHEN COMPUTER IS IN “S.A.F.E. SYSTEM IS DISABLED” MODE
NON-COIN – When the S.A.F.E. system is disabled, the user can still start a cycle. However, when a cycle is
started, the control will display the following message: “S.A.F.E. SYSTEM IS DISABLED. PRESS ‘START’TO
CONTINUE.” This message will be displayed every time a cycle is started, until the disabling condition has been
corrected.
COIN – When the S.A.F.E. system is disabled, the user can still start a cycle. Simply insert credit and select a
cycle to start.
113222-5
45
Download from Www.Somanuals.com. All Manuals Search And Download.
ADC Part No. 113222
5 - 06/03/08 - 100
Download from Www.Somanuals.com. All Manuals Search And Download.
|