WARNING  
Electric Shock Hazard - High voltage exists  
within this equipment. There are no user  
serviceable parts in this equipment. All  
installation and service to this equipment  
should be performed by qualified licensed  
personnel.  
Do not exceed 30 minutes in a steambath.  
Excessive exposure can be harmful to your  
health. Excessive exposure can produce a  
rapid pulse, light-headedness, weakness  
or fainting. If you become uncomfortable  
or experience any of the above conditions  
exit the steambath immediately.  
AMEREC STEAMBATH GENERATORS  
(MODELS: AK5, AK7, AK10 w/K60 CONTROL)  
Steambaths can put stress on the body.  
Therefore a steambath should be used  
only under a doctor's direction if you:  
Are pregnant  
Have a heart condition  
Have high blood pressure  
Have circulatory problems  
Are under the influence of alcohol  
Are under the influence of drugs  
Have diabetes  
Are under the care of a physician  
Are in generally poor health  
Children should only use the steambath  
under close adult supervision.  
FOR THE SAFETY OF YOU AND YOUR FAMILY PLEASE READ THE  
WARNINGS TO THE RIGHT AND ALL INSTRUCTIONS BEFORE USING  
YOUR STEAMBATH.  
Scald Hazard: Do Not Touch the steam  
head or trim during operation as they are  
HOT. Stay at least 12 inches away from the  
hot steam escaping from the steam head.  
POST "STEAMBATH INSTRUCTIONS" LABEL OUTSIDE STEAMBATH  
FOR SAFETY WARNINGS.  
Be careful when entering a steambath.  
Escaping steam from an overheated steam  
room may cause injury.  
SAVETHISMANUAL  
Thank you for purchasing your new AMEREC steam generator. If we can be of any assistance  
do not hesitate to call our Service Department at 1-800-331-0349.  
4209-24 12-09-02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AK Series w/K60 Control Owners Manual  
page 3  
SECTION 5: TROUBLE SHOOTING GUIDE  
Thetroubleshootingguideismeantasageneralaidonly. Therearenouserserviceablepartsinthegenerator. Allrepairsshouldbeperformedbyaqualifiedservice  
person. Foradditionalassistanceorthefactoryauthorizedservicepersonnearestyoucall: AMEREC'sServiceDepartmentat1-800-331-0349.  
SYMPTOMS  
PROBABLE CAUSES  
ACTION TO BE TAKEN  
Control won't turn "ON".  
(Control light off).  
Improper power supplied (no power).  
1. a. Make sure circuit breaker is "ON".  
or  
b. Using a voltmeter, check the voltage across the two fuses on the "PCA"  
printed circuit assembly. Voltage should be 208V / 240V.  
c. Check fuses, if the fuse(s) are blown, replace with Buss#  
MDL 15/100 or equivalent fuse. If the fuse blows again - call AMEREC's  
Service Department.  
Control improperly connected.  
or  
Control cable is faulty.  
or  
Contol is faulty.  
2. Check control(s) installed per Section 6-5 in the AK INSTALLATION AND  
SERVICE INSTRUCTIONS.  
3. Replace control cable - call AMEREC's Service Department.  
4. Replace the control - Call AMEREC's Service Department.  
1. Turn off the circuit breaker.  
Control "OFF".  
Unit still makes steam.  
Generator is faulty.  
Generator is faulty.  
2. Call AMEREC's Service Department.  
1. Turn off the circuit breaker.  
Water runs out of steam head.  
2. Turn off the water.  
3. Call AMEREC's Service Department.  
Steam room too hot or cold.  
Temperature adjustment needs setting. 1. See Section 3, "Temperature Adjustment".  
2. Call AMEREC's Service Department.  
Control "ON".  
Temperature sensor not connected.  
1. Check that the sensor cable is connected to J4 on the PCA printed circuit  
K60 Control displays "E001".  
assembly.  
2. Check the cable connection to the temperature sensor.  
3. Replace sensor and/or cable - call AMEREC's Service Department.  
1. Check sensor cable for damage from nail/staple puncture.  
Control "ON".  
K60 Control displays "E002".  
Temperature sensor.  
or  
cable shorted.  
2. Check sensor cable ends for frayed/exposed wire strands.  
3. Replace sensor and/or cable - call AMEREC's Service Department.  
Control "ON".  
Steambath temperature over 132 º.  
1. If bath is too hot, shut off circuit breaker and call AMEREC's Service Department.  
K60 Control displays ">>>º".  
or  
Sensor/cable is faulty.  
2. Treat as "E002" fault above.  
Control won't turn "OFF".  
(Control light on).  
Control is faulty.  
1. Replace the control - call AMEREC's Service Department.  
Control "ON". (Control light on)  
Unit won't steam.  
Unit has not filled completely.  
1. Wait at least 10 minutes after turning on the control.  
2. Call AMEREC's Service Department.  
or  
Generator is faulty.  
Note: Time/Temp properly.  
displayed on K60.  
Unable to adjust Time or Temp  
setting with K60.  
Control is faulty.  
or  
1. Replace control - call AMEREC's Service Department.  
Generator is faulty.  
2. Replace PCA - call AMEREC's Service Department.  
1. Flush tank 3 times. See Section 4.  
Sudden increases in rate water  
sputters out of steam head.  
Foaming contaminants in the water  
supply.  
4209-24 12/09/02  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AK Series w/K60 Control Owners Manual  
page 4  
3
21  
33  
34  
39  
44  
35  
36  
15  
23  
29  
28  
11  
9
16  
12  
1
43  
7
13  
4
2
24  
17  
18  
5
22  
6
20  
8
19  
14  
P.O. Box2258, WoodinvilleWA98072  
425-951-1120 Fax: 425-951-1130  
email address:amerec@amerec.com  
4209-24 12-09-02  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Abocom Network Card USM560 User Manual
Addonics Technologies Network Card ADST114R5 User Manual
ADTRAN Network Card HRE T200 User Manual
ADTRAN Network Card TSU LT User Manual
Altec Lansing Laptop XT2 User Manual
Altec Lansing Speaker ATP3 User Manual
Ask Proxima Projector AV 9350 User Manual
ATI Technologies Computer Hardware X1800 User Manual
Atlantis Land Switch A02 G8 User Manual
BC Speakers Portable Speaker DE750 User Manual