Amcor Dehumidifier AD 400E User Manual

OneYear LimitedWarranty  
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the  
United States that the Amcor product with which this warranty is enclosed is free from defects  
in materials and workmanship.  
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair,  
free of charge, all defective parts, for a period of one (1) year from date of original purchase.  
ANY IMPLIEDWARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITEDTO ONE (1)  
YEAR FROM DATE OF ORIGINAL PURCHASE AND NO ACTION BASED UPON ANY  
IMPLIE
D
W
ARRANTY OF MERCHAN
T
A
BILITY OR OTHERWISE M
A
Y
B
E COMMENCED  
AFTER EXPIRATION OF ONE (1)YEAR FROM DATE OF ORIGINAL RETAIL PURCHASE.  
Some states do not allow limitations on how long an implied warranty lasts,so the above limitation  
may not apply to you.  
Dehumidifier  
Owner’s Manual  
For model AD 400E  
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has  
been (1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for  
which it was not designed, or (4) repaired or altered in any way that adversely affected its  
performance or reliability.  
To obtain warranty service, the defective product or part must be shipped or delivered to:  
Amcor’s authorized service center. All postage,insurance and shipping charges are the responsibility  
of the Purchaser and are not included in this warranty.  
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSO
N
T
O ASSUME FOR IT ANY  
OTHER ( LIABILITY IN CONNECTIONWITH ITS PRODUCTS,THEREARE NOWARRANTIES  
WHICH EXTEND BEYONDTHE DESCRIPTION ONTHE FACE HEREOF. NO RESPONSIBILITY  
ISASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGESTHAT MAY RESULT FROM  
THE USE OFANAMCOR PRODUCT,NOR FORTHE DAMAGES DUETOACCIDENT, ABUSE,  
LACK OF RESPONSIBLE CARE,THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT,  
LOSS OF PARTS, OR USEATAVOLTAGE OTHERTHAN SPECIFIED. Some states do not allow  
the exclusion of limitation of incidental or consequential damages, so these limitations may not  
apply to you.  
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained  
from or by service at any service center other than Amcor’s authorized service center.  
This warranty gives you specific legal rights, and you may also have other rights which vary from  
state to state.  
Product: AMCOR Dehumidifier  
Model: AD 400E  
Leave  
upright at  
least 2 hours  
before use!  
Date Purchased:_____________________________________ Production Code:________  
It is important that you read  
these instructions before  
using your new purchase and  
we strongly recommend that  
you keep them in a safe place  
for future reference.  
Dear Customer: Please keep this warranty for your record. DO NOT return it.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance - End of Season Storage  
Thank You!  
Thank you for choosing thisAmcor Dehumidifier. This owner's Manual will provide you with valuable  
information necessary for the proper care and maintenance of your new appliance. If properly  
maintained, your dehumidifier will give you many years of trouble-free operation. Please take a few  
moments and read the instructions thoroughly and familiarize yourself with all of the operational  
aspects of this appliance.  
Draining theWaterTray  
For storage or in case of pump failure and before moving.  
Read all instructions before using this dehumidifier. To reduce the risk of fire, electric shock, or injury  
to persons when using your dehumidifier, follow basic safety precautions, including the following:  
To empty the internal tank remove the rubber plug under the unit.  
After draining all the water, reinsert the rubber plug.  
Important Safeguards  
1. After transporting the dehumidifier, wait 2 hours before using it.  
2. Do not store or use gasoline, oil, sulphur or other flammable vapors and liquids in the vicinity of this  
or any other appliance. Do not install the appliance near source of heat. Read product labels carefully.  
Common sense and caution must be used when installing, operating and maintaining any appliance.  
3. This appliance must be used by adults only. Do not allow children to play with the appliance.  
Do not leave children unattended in an area where the appliance is operating. Do not allow  
them to sit or stand on the appliance.  
4. This appliance is designed to dehumidify domestic living areas, and must not be used for other  
purposes. It must be operated in an enclosed area to be most effective.  
Close all doors, windows, and other outside openings to the room.  
5. The appliance must not be modified in any way, as any modifications may be extremely dangerous.  
6. Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or  
has been damaged in any manner. Return appliance to the nearest authorized service facility for examination,  
repair or adjustment.  
7. The use of accessory attachments is not recommended by the appliance manufacturer.  
It may cause injuries.  
8. Do not use outdoors.  
9. For your safety and protection, this dehumidifier is equipped with a three-prong grounding plug on the  
power cord. Do not, under any circumstances, cut or remove the round grounding prong from  
the plug.  
10. Your dehumidifier must plug directly into a properly grounded and polarized three-prong outlet.  
If the wall outlet will not accept a three prong plug, or if you are not sure the outlet is adequately grounded  
or protected by a time delay (use or circuit breaker, have a qualified electrician install the proper outlet.  
Do not use an extension cord or an adapter plug.  
Tray  
11. Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly and  
pull straight out from the outlet. Do not pinch, bend, or knot the power cord.  
12. Always remove the plug from the socket before performing cleaning or maintenance operations and  
when not in use.  
13. Do not place heavy or hot objects on the top of the appliance.  
14. Clean the air filter every two weeks.  
15. The appliance must always remain upright or laid on one side during transportation.  
Remember to drain the tank before transporting the appliance.  
8
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Maintenance  
Always unplug the unit from the wall outlet before beginning cleaning.  
The unit is equipped with a washable filter. Follow the instructions below to remove and clean it.  
How to Remove Filter  
Take out the air filter by pressing the top of the air inlet grill (as shown in fig.1).  
Model Number  
AD 400E  
Pull out the grill (fig.2) and extract the filter (fig.3).  
Power Supply  
120V / 60Hz / 1 Phase  
446W / 3.92A  
43.5 pints / Day  
R-22 / 11.8 oz.  
46.3 lbs.  
Power Consumption  
Humidity Removal Capacity  
Refrigerant  
Weight  
Dimensions  
16"W x 28"D x 10"H  
fig.2  
fig.3  
fig.1  
Cleaning the Filter  
• Wash
 
filter in warm wate
r
.  
• Shake out excess water, lay flat, away from heat, until thoroughly dry.  
• Do not use hot water, solvents, detergent, or abrasive, material to clean filter.  
This may damage the element.  
• Clean filter every two weeks.  
To clean the outside of unit, use moist cloth. Avoid detergent and abrasive wipes.  
2
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Special Features  
Operation  
Contro  
1. Automatic Dehumidification  
After setting the desired humidity, the unit will maintain the desired humidity automatically.  
2. Continuous Drainage  
In order to remove excessive moisture from the air, with a minimum amount of attention,  
the humidifier is equipped with a pump to continually discharge condensed water.  
The continuous drainage point is high at the back of the unit, making it easy to reach and  
convenient to attach the supplied drainage tube. Water can be collected in a large container,  
or pumped to the outside.  
Operation Instruction  
1. POWER
 
KEY  
Press to turn unit “ON” or “OFF”.  
3. Air Filter  
The dehumidifier features a cartridge type washable air filter. To access it press the top  
of the front grill. Once cleaned, again press the front grill back into position to lock the  
filter in place.  
2. FAN
 
SPEED  
Press to select fan speed “HI” or “LOW”.  
3. TIMER  
IMPOR
T
A
NT  
a. Press the “TIMER” key to set the time desired (1-24 hour).  
b. Once the set time has come to an end, the unit will turn off automatically.  
c. Pressing the “POWER” key before the set time has been reached,  
the set time will be canceled when the unit turns off.  
The operational temperature range for this unit is 41
°
F to 95º
F
.  
This dehumidifier should not be used at temperatures below 41
°
F.  
Running the unit above the temperature of 95ºF will cause the compressor  
to stop as its over heat protector becomes activated.  
4. HUMIDITY
 
SETTING  
Press to select the Humidity desired (RH 80% / 70 % / 60 % / 50 % / or CONTINOUS).  
When the room humidity is less than the selected humidity, the unit will turn off automatically.  
The unit will turn on automatically when the room humidity is higher than the selected humidity.  
Actual Humidity and Indicated Humidity may vary by 5% (+ or -).  
5. ALARM
 
INDIC
A
TOR  
If this indicator illuminates, it means the water pump can not drain the water from the tank.  
Check to see that the drain hose is not blocked or bent, restricting the water flow.  
6. DEFROST  
Periodically the defrost light will come on to indicate that the ice that forms as part of the process  
at low room temperatures is being melted off the cold internal coil. It should go off once the  
coil is sufficiently frost free to continue effective dehumidification.  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Operation  
1. Top Cover  
2. Control
 
Panel  
3. Air
 
Inlet  
InstallingThe Drainage Hose  
The drainage hose can be put into any suitable area where water can be emptied.  
The hose can be run under doors, through a hole in the wall, or through a vent.  
Attention should given to the flow of the drained water to be sure it flows away from buildings  
and other objects that could be damaged.  
4. Front
 
Panel  
5. Air
 
Outlet  
6. Handle  
CAUTION: The drainage hose MUST NOT be installed more than six (6)  
feet above the floor on which the unit is standing.  
7. Side
 
Panel  
Maintaining Set Humidity Level  
After setting the desired humidity, the unit will run automatically, maintaining the desired humidity.  
The Relative Humidity may be set from RH 40% to RH 70 %  
The operational temperature for this unit is between 41
°
F and 95
°
F. If the temperature of the room  
falls below 41
°
F, the unit will stop.This function protects the compressor, and is normal.  
The unit will operate when the temperature is within the operational range.  
When the unit is operating, heat is produced, this will increase the room temperature slightly.  
This is a normal condition.  
8. Castor
 
Wheel  
9. Permanent
 
Drain Outlet  
10. Power
 
Cord  
11. Drain
 
Hose  
6
3
Download from Www.Somanuals.com. All Manuals Search And Download.  

Agilent Technologies Yard Vacuum 437B User Manual
Air King Blower AK110 User Manual
Alliance Laundry Systems Washer Topload Washer User Manual
Atlona Router AT HDVS RX User Manual
ATN Binoculars NVM14 3 User Manual
Audiovox Automobile Alarm AA 940 User Manual
Audiovox Car Stereo System ACC 50A User Manual
Axis Communications Security Camera 25734 User Manual
Behringer TV Cables UFO202 User Manual
Beko Double Oven DVC665 User Manual