Amana Microwave Oven AMV1160VA User Manual

®
Microwave Hood Combination  
PRODUCT MODEL NUMBERS  
AMV1160VA AMV2174VA  
PRODUCT DIMENSIONS  
Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20-amp fused electrical  
supply with a fuse or circuit breaker. A time-delay fuse or time-delay circuit  
breaker is recommended. It is recommended that a separate circuit serving  
only this microwave oven be provided.  
16¹⁄₄"  
(41.3 cm)  
17¹⁄₄"  
(43.8 cm)  
VENTING REQUIREMENTS  
A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.  
The total length of the vent system including straight vent, elbow(s), transitions and wall  
or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent.  
For best performance, use no more than three 90° elbows.  
To calculate the length of the system you need, add the equivalent length for each vent  
piece used in the system. See the following examples:  
CABINET OPENING DIMENSIONS  
The grounded 3 prong outlet must be inside the upper cabinet.  
A
B
C
A
B
30"  
(76.2 cm)  
min.  
30" (76.2 cm) typical*  
12" (30.5 cm) min.  
14" (35.6 cm) max.  
D
E
F
G
A. Rectangular to round transition piece: 3¹⁄₄" x 10" to 6" = 5 ft  
(8.3 x 25.4 cm to 15.2 cm = 1.5 m)  
66" (167.6 cm) min.  
B. Roof cap: 3¹⁄₄" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)  
C. 90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)  
D. 90° elbow: 6" = 10 ft (15.2 cm = 3 m)  
E. Wall cap: 3¹⁄₄" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)  
F. 45° elbow: 6" = 5 ft (15.2 cm = 1.5 m)  
G. 90° flat elbow: 3¹⁄₄" x 10" = 10 ft (8.3 x 25.4 cm = 3 m)  
6" (15.2 cm) vent system = 73 ft (22.2 m) total  
A
B
6 ft (1.8 m)  
2 ft  
(0.6 m)  
A. 2" x 4" wall stud  
B. Grounded 3-prong outlet  
*30" (76.2 cm) is typical for 66" (167.6 cm) installation height.  
Exact dimensions may vary depending on type of range/cooktop  
below.  
C
D
A. Two 90° elbows = 20 ft (6.1 m)  
B. 1 wall cap = 40 ft (12.2 m)  
C. 1 rectangular to round transition piece = 5 ft (1.5 m)  
D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)  
Rectangular to Round Transition for Roof Venting  
NOTE: The minimum 3" (7.6 cm) clearance must exist between  
the top of the microwave oven and the rectangular to round  
transition piece so that the damper can open freely and fully.  
3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total  
A
B
A
6 ft (1.8 m)  
B
2 ft  
(0.6 m)  
D
C
A. Roof cap  
B. 6" (15.2 cm) min. diameter round vent  
C. Elbow (for wall venting only)  
D. Wall cap  
E. 3¹⁄₄" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)  
rectangular to round transition piece  
C
E
F
A. One 3¹⁄₄" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)  
B. 1 wall cap = 40 ft (12.2 m)  
C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)  
3" (7.6 cm)  
F. Vent extension piece, at least 3" (7.6 cm) high  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10191951  
09-15-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Switch Hub 1000 SX User Manual
3M Oxygen Equipment 7800S User Manual
AB Soft Network Router TDW 33 User Manual
Acer Home Theater System XD1150 User Manual
Agilent Technologies Work Light 8163A User Manual
Air King Thermostat KWN105P106 10000 User Manual
Ativa Flat Panel Television AT24OHP User Manual
Audiovox Stereo System AV 428V User Manual
Axis Communications Security Camera 233D User Manual
Axis Communications TV Mount AXIS T94B01S User Manual