Amana Clothes Dryer W10150612B User Manual

29" (73.7 CM) ELECTRIC DRYER  
INSTALLATION INSTRUCTIONS  
INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE  
ÉLECTRIQUE DE 29" (73,7 CM)  
Table of Contents / Table des matières  
DRYER SAFETY............................................... 1  
SÉCURITÉ DE LA SÉCHEUSE ......................16  
INSTALLATION INSTRUCTIONS.................... 2  
Tools and Parts ............................................. 2  
Location Requirements ................................ 2  
Electrical Requirements - U.S.A. .................. 3  
Electrical Requirements - Canada................ 5  
Electrical Connection - U.S.A. Only.............. 6  
Venting Requirements................................. 11  
Plan Vent System........................................ 12  
Install Vent System...................................... 13  
Install Leveling Legs.................................... 13  
Level Dryer .................................................. 13  
Connect Vent............................................... 13  
Reverse Door Swing (Optional)................... 14  
Complete Installation .................................. 15  
INSTRUCTIONS D’INSTALLATION...............17  
Outillage et pièces .......................................17  
Exigences d’emplacement ..........................17  
Spécifications électriques- Canada.............18  
Exigences concernant l'évacuation.............19  
Planification du système d’évacuation........20  
Installation du système d’évacuation ..........21  
Installation des pieds de nivellement...........21  
Mise à niveau de la sécheuse......................22  
Raccordement du conduit d’évacuation.....22  
Inversion du sens d'ouverture de la  
porte (facultatif) ............................................22  
Achever l’installation....................................23  
Para obtener acceso al manual de uso y cuidado en español, o para obtener información adicional acerca de su producto, visite:  
Tenga listo su número de modelo completo. Puede encontrar el número de modelo y de serie dentro de la cavidad superior de la  
puerta.  
DRYER SAFETY  
Your safety and the safety of others are very important.  
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety  
messages.  
This is the safety alert symbol.  
This symbol alerts you to potential hazards that can kill or hurt you and others.  
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”  
These words mean:  
You can be killed or seriously injured if you don't immediately  
follow instructions.  
DANGER  
You can be killed or seriously injured if you don't  
instructions.  
follow  
WARNING  
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can  
happen if the instructions are not followed.  
W10150612B  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Companion appliance spacing should also be considered.  
Installation Clearances  
The location must be large enough to allow the dryer door to open  
3"*  
(76 mm)  
fully.  
14" max.*  
(356 mm)  
Dryer Dimensions  
48 in.2  
*
(310 cm2 )  
18"*  
(457 mm)  
15¼"  
(387 mm)  
22¾"  
(578 mm)  
433  
8
"
433  
8
"
2
*
(1102 mm)  
(1102 mm)  
24 in.  
3"*  
(76 mm)  
(155 cm2 )  
1"  
(25 mm)  
27¾"  
(705 mm) (127 mm)  
5"*  
29"  
(737 mm)  
1"  
(25 mm)  
1"*  
(25 mm)  
*27¾"  
*26"  
B
C
A
(660 mm)  
(705 mm)  
29"  
29"  
A. Recessed area  
(737 mm)  
(737 mm)  
B. Side view - closet or confined area  
C. Closet door with vents  
B
A
*Required spacing  
22¾"  
(578 mm)  
Mobile Home - Additional Installation Requirements  
This dryer is suitable for mobile home installations.  
The installation must conform to the Manufactured Home  
Construction and Safety Standard, Title 24 CFR, Part 3280  
433  
"
8
433  
8
"
(1102 mm)  
(1102 mm)  
13¾"  
(349 mm)  
(formerly the Federal Standard for Mobile Home Construction and  
Safety, Title 24, HUD Part 280) or the Canadian Manufactured  
Home Standard, CAN/CSA-Z240 MH.  
*27¾"  
*27¾"  
(705 mm)  
(705 mm)  
29"  
29"  
Mobile home installations require:  
(737 mm)  
(737 mm)  
Metal exhaust system hardware, which is available for  
purchase from your dealer.  
C
D
A. Small opening side-swing door  
B. Large opening side-swing door  
C. Wide opening side-swing door  
D. Wide opening hamper door  
Special provisions must be made in mobile homes to  
introduce outside air into the dryer. The opening (such as a  
nearby window) should be at least twice as large as the dryer  
exhaust opening.  
*Most installations require a minimum 5" (127 mm) clearance  
behind the dryer for the exhaust vent with elbow. See “Venting  
Requirements.”  
Electrical Requirements - U.S.A.  
It is your responsibility  
Installation spacing for recessed area or closet installation  
To contact a qualified electrical installer.  
The following spacing dimensions are recommended for this  
dryer. This dryer has been tested for spacing of 0" (0 mm)  
clearance on the sides and rear. Recommended spacing should  
be considered for the following reasons:  
To be sure that the electrical connection is adequate and in  
conformance with the National Electrical Code, ANSI/NFPA  
70-latest edition and all local codes and ordinances.  
Additional spacing should be considered for ease of  
installation and servicing.  
The National Electrical Code requires a 4-wire supply  
connection for homes built after 1996, dryer circuits involved  
in remodeling after 1996, and all mobile home installations.  
Additional clearances might be required for wall, door,  
and floor moldings.  
A copy of the above code standards can be obtained from:  
National Fire Protection Association, One Batterymarch Park,  
Quincy, MA 02269.  
Additional spacing should be considered on all sides of the  
dryer to reduce noise transfer.  
For closet installation, with a door, minimum ventilation  
openings in the top and bottom of the door are required.  
Louvered doors with equivalent ventilation openings are  
acceptable.  
To supply the required 3 or 4 wire, single phase, 120/240 volt,  
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt  
electrical supply, if specified on the serial/rating plate) on a  
separate 30-amp circuit, fused on both sides of the line. A  
time-delay fuse or circuit breaker is recommended. Connect  
to an individual branch circuit. Do not have a fuse in the  
neutral or grounding circuit.  
Do not use an extension cord.  
If codes permit and a separate ground wire is used, it is  
recommended that a qualified electrician determine that the  
ground path is adequate.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
If your outlet looks like this:  
Electrical Connection  
To properly install your dryer, you must determine the type of  
electrical connection you will be using and follow the instructions  
provided for it here.  
If local codes do not permit the connection of a neutral ground  
wire to the neutral wire, see “Optional 3-wire connection”  
section.  
3-wire receptacle (10-30R)  
This dryer is manufactured ready to install with a 3-wire  
electrical supply connection. The neutral ground wire is  
permanently connected to the neutral conductor (white wire)  
within the dryer. If the dryer is installed with a 4-wire electrical  
supply connection, the neutral ground wire must be removed  
from the external ground conductor screw (green screw), and  
secured under the neutral terminal (center or white wire) of the  
terminal block. When the neutral ground wire is secured under  
the neutral terminal (center or white wire) of the terminal block,  
the dryer cabinet is isolated from the neutral conductor.  
Then choose a 3-wire power supply cord with ring or spade  
terminals and UL listed strain relief. The 3-wire power supply cord,  
at least 4 ft (1.22 m) long, must have three 10-gauge solid copper  
wires and match a 3-wire receptacle of NEMA Type 10-30R.  
If connecting by direct wire:  
Power supply cable must match power supply (4-wire or 3-wire)  
and be:  
Flexible armored cable or nonmetallic sheathed copper cable  
(with ground wire), protected with flexible metallic conduit. All  
current-carrying wires must be insulated.  
A 4-wire power supply connection must be used when the  
appliance is installed in a location where grounding through  
the neutral conductor is prohibited. Grounding through the  
neutral is prohibited for (1) new branch-circuit installations,  
(2) mobile homes, (3) recreational vehicles, and (4) areas  
where local codes prohibit grounding through the neutral  
conductors.  
10-gauge solid copper wire (do not use aluminum).  
At least 5 ft (1.52 m) long.  
GROUNDING INSTRUCTIONS  
If using a power supply cord:  
Use a UL listed power supply cord kit marked for use with clothes  
dryers. The kit should contain:  
For a grounded, cord-connected dryer:  
This dryer must be grounded. In the event of malfunction or  
breakdown, grounding will reduce the risk of electric shock  
by providing a path of least resistance for electric current.  
This dryer uses a cord having an equipment-grounding  
conductor and a grounding plug. The plug must be plugged  
into an appropriate outlet that is properly installed and  
grounded in accordance with all local codes and ordinances.  
A UL listed 30-amp power supply cord, rated 120/240 volt  
minimum. The cord should be type SRD or SRDT and be at  
least 4 ft (1.22 m) long. The wires that connect to the dryer  
must end in ring terminals or spade terminals with upturned  
ends.  
A UL listed strain relief.  
For a permanently connected dryer:  
If your outlet looks like this:  
This dryer must be connected to a grounded metal,  
permanent wiring system, or an equipment-grounding  
conductor must be run with the circuit conductors and  
connected to the equipment-grounding terminal or lead on  
the dryer.  
4-wire receptacle (14-30R)  
WARNING: Improper connection of the equipment-  
grounding conductor can result in a risk of electric shock.  
Check with a qualified electrician or service representative  
or personnel if you are in doubt as to whether the dryer is  
properly grounded. Do not modify the plug on the power  
supply cord: if it will not fit the outlet, have a proper outlet  
installed by a qualified electrician.  
Then choose a 4-wire power supply cord with ring or spade  
terminals and UL listed strain relief. The 4-wire power supply cord,  
at least 4 ft (1.22 m) long, must have 4 10-gauge solid copper  
wires and match a 4-wire receptacle of NEMA Type 14-30R.  
The ground wire (ground conductor) may be either green or bare.  
The neutral conductor must be identified by a white cover.  
SAVE THESE INSTRUCTIONS  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Requirements - Canada  
This dryer is equipped with a CSA International Certified  
Power Cord intended to be plugged into a standard 14-30R  
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure wall  
receptacle is within reach of dryer’s final location.  
WARNING  
Electrical Shock Hazard  
Plug into a grounded 4 prong outlet.  
4-wire receptacle 14-30R  
Failure to do so can result in death or electrical shock.  
Do not use an extension cord.  
If you are using a replacement power supply cord, it is  
recommended that you use Power Supply Cord Replacement  
Part Number 3394208. For further information, please reference  
It is your responsibility  
To contact a qualified electrical installer.  
the service numbers located in the Dryer User Instructions  
.
To be sure that the electrical connection is adequate and in  
conformance with the Canadian Electrical Code, C22.1-latest  
edition and all local codes. A copy of the above codes  
standard may be obtained from: Canadian Standards  
Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3  
CANADA.  
GROUNDING INSTRUCTIONS  
For a grounded, cord-connected dryer:  
This dryer must be grounded. In the event of malfunction or  
breakdown, grounding will reduce the risk of electric shock  
by providing a path of least resistance for electric current.  
This dryer is equipped with a cord having an equipment-  
grounding conductor and a grounding plug. The plug must  
be plugged into an appropriate outlet that is properly  
installed and grounded in accordance with all local codes  
and ordinances.  
To supply the required 4 wire, single phase, 120/240 volt,  
60 Hz., AC only electrical supply on a separate 30-amp circuit,  
fused on both sides of the line. A time-delay fuse or circuit  
breaker is recommended. Connect to an individual branch  
circuit.  
WARNING: Improper connection of the equipment-  
grounding conductor can result in a risk of electric shock.  
Check with a qualified electrician or service representative  
or personnel if you are in doubt as to whether the dryer is  
properly grounded. Do not modify the plug provided with the  
dryer: if it will not fit the outlet, have a proper outlet installed  
by a qualified electrician.  
SAVE THESE INSTRUCTIONS  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Connection - U.S.A. Only  
Power Supply Cord  
Direct Wire  
WARNING  
WARNING  
Fire Hazard  
Fire Hazard  
Use 10 gauge solid copper wire.  
Use a new UL listed 30 amp power supply cord.  
Use a UL listed strain relief.  
Use a UL listed strain relief.  
Disconnect power before making electrical connections.  
Disconnect power before making electrical connections.  
Connect neutral wire (white or center wire) to center  
terminal (silver).  
Connect neutral wire (white or center wire) to center  
terminal (silver).  
Ground wire (green or bare wire) must be connected to  
green ground connector.  
Ground wire (green or bare wire) must be connected to  
green ground connector.  
Connect remaining 2 supply wires to remaining  
2 terminals (gold).  
Connect remaining 2 supply wires to remaining  
2 terminals (gold).  
Securely tighten all electrical connections.  
Securely tighten all electrical connections.  
Failure to do so can result in death, fire, or  
electrical shock.  
Failure to do so can result in death, fire, or  
electrical shock.  
1. Disconnect power.  
3. Install strain relief.  
2. Remove the hold-down screw and terminal block cover.  
Style 1: Power supply cord strain relief  
3
Remove the screws from a 4" (19 mm) UL listed strain  
A
B
C
D
relief (UL marking on strain relief). Put the tabs of the two  
clamp sections into the hole below the terminal block  
opening so that one tab is pointing up and the other is  
pointing down, and hold in place. Tighten strain relief  
screws just enough to hold the two clamp sections  
together.  
A
B
C
D
E
F
A. Strain relief tab pointing up  
B. Hole below terminal block opening  
C. Clamp section  
D. Strain relief tab pointing down  
A. Terminal block cover  
B. External ground conductor screw  
C. Center, silver-colored terminal block screw  
D. Hold-down screw location  
E. Neutral ground wire  
F. Hole below terminal block opening  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Put power supply cord through the strain relief. Be sure  
that the wire insulation on the power supply cord is inside  
the strain relief. The strain relief should have a tight fit with  
the dryer cabinet and be in a horizontal position. Do not  
further tighten strain relief screws at this point.  
Electrical Connection Options  
If your home has:  
And you will be  
connecting to:  
Go to Section  
4-wire receptacle  
(NEMA Type 14-30R)  
A UL listed,  
120/240-volt  
minimum,  
4-wire connection:  
Power supply cord  
30-amp, dryer  
power supply  
cord*  
4-wire direct  
A fused  
4-wire connection:  
Direct Wire  
disconnect or  
circuit breaker  
box*  
5"  
(127 mm)  
Style 2: Direct wire strain relief  
3-wire receptacle  
(NEMA type 10-30R)  
A UL listed,  
120/240-volt  
minimum,  
30-amp, dryer  
power supply  
cord*  
3-wire connection:  
Power supply cord  
Unscrew the removable conduit connector and any  
screws from a 34" (19 mm) UL listed strain relief (UL  
marking on strain relief). Put the threaded section of the  
strain relief through the hole below the terminal block  
opening. Reaching inside the terminal block opening,  
screw the removable conduit connector onto the strain  
relief threads.  
3-wire direct  
A fused  
3-wire connection:  
Direct Wire  
disconnect or  
circuit breaker  
box*  
312  
"
(89 mm)  
A
B
*If local codes do not permit the connection of a cabinet-ground  
conductor to the neutral wire, go to “Optional 3-wire connection”  
section.  
4-wire connection: Power Supply Cord  
IMPORTANT: A 4-wire connection is required for mobile homes  
and where local codes do not permit the use of 3-wire  
connections.  
C
F
B
A. Removable conduit connector  
B. Hole below terminal block opening  
C. Strain relief threads  
A
Put direct wire cable through the strain relief. The strain  
relief should have a tight fit with the dryer cabinet and be  
in a horizontal position. Tighten strain relief screw against  
the direct wire cable.  
D
G
E
C
A. 4-wire receptacle (NEMA type 14-30R)  
B. 4-prong plug  
C. Ground prong  
D. Neutral prong  
E. Spade terminals with upturned ends  
F. ¾" (19 mm) UL listed strain relief  
G. Ring terminals  
4. Now complete installation following instructions for your type  
of electrical connection:  
4-wire (recommended)  
3-wire (if 4-wire is not available)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Remove center silver-colored terminal block screw.  
4-wire connection: Direct Wire  
2. Remove neutral ground wire from external ground conductor  
screw. Connect neutral ground wire and the neutral wire (white  
or center wire) of power supply cord under center, silver-  
colored terminal block screw. Tighten screw.  
IMPORTANT: A 4-wire connection is required for mobile homes  
and where local codes do not permit the use of 3-wire  
connections.  
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer  
can be moved if needed.  
A
C
B
Strip 5" (127 mm) of outer covering from end of cable, leaving  
bare ground wire at 5" (127 mm). Cut 112" (38 mm) from  
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends  
of wires into a hook shape.  
E
D
When connecting to the terminal block, place the hooked end of  
the wire under the screw of the terminal block (hook facing right),  
squeeze hooked end together and tighten screw, as shown.  
A. External ground conductor screw - Dotted line shows  
position of NEUTRAL ground wire before being moved to  
center silver-colored terminal block screw.  
B. Center silver-colored terminal block screw  
C. Neutral wire (white or center wire)  
D. ¾" (19 mm) UL listed strain relief  
E. Neutral ground wire  
3. Connect ground wire (green or bare) of power supply cord to  
external ground conductor screw. Tighten screw.  
A
C
B
1. Remove center silver-colored terminal block screw.  
2. Remove neutral ground wire from external ground conductor  
screw. Connect neutral ground wire and place the hooked end  
(hook facing right) of the neutral wire (white or center wire) of  
direct wire cable under the center screw of the terminal block.  
Squeeze hooked ends together. Tighten screw.  
A
B
C
F
E
D
A. External ground conductor screw  
B. Center silver-colored terminal block screw  
C. Neutral wire (white or center wire)  
D. ¾" (19 mm) UL listed strain relief  
E. Ground wire (green or bare) of power supply cord  
F. Neutral ground wire  
E
D
4. Connect the other wires to outer terminal block screws.  
Tighten screws.  
A. External ground conductor screw - Dotted line shows  
position of NEUTRAL ground wire before being moved to  
center silver-colored terminal block screw.  
B. Center silver-colored terminal block screw  
C. Neutral wire (white or center wire)  
D. ¾" (19 mm) UL listed strain relief  
E. Neutral ground wire  
5. Tighten strain relief screws.  
6. Insert tab of terminal block cover into slot of dryer rear panel.  
Secure cover with hold-down screw.  
7. You have completed your electrical connections. Now go to  
“Venting Requirements.”  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Connect ground wire (green or bare) of power supply cable to  
1. Loosen or remove center silver-colored terminal block screw.  
external ground conductor screw. Tighten screw.  
2. Connect neutral wire (white or center wire) of power supply  
cord to the center, silver-colored terminal screw of the terminal  
block. Tighten screw.  
A
B
C
B
C
D
E
F
E
D
A
A. External ground conductor screw  
B. Center silver-colored terminal block screw  
C. Neutral wire (white or center wire)  
D. ¾" (19 mm) UL listed strain relief  
E. Ground wire (green or bare) of power supply cable  
F. Neutral ground wire  
A. Neutral ground wire  
B. External ground conductor screw  
C. Center silver-colored terminal block screw  
D. Neutral wire (white or center wire)  
E. ¾" (19 mm) UL listed strain relief  
4. Place the hooked ends of the other power supply cable wires  
under the outer terminal block screws (hooks facing right).  
Squeeze hooked ends together. Tighten screws.  
3. Connect the other wires to outer terminal block screws.  
Tighten screws.  
4. Tighten strain relief screws.  
5. Insert tab of terminal block cover into slot of dryer rear panel.  
Secure cover with hold-down screw.  
6. You have completed your electrical connections. Now go to  
“Venting Requirements.”  
3-wire connection: Direct Wire  
5. Tighten strain relief screws.  
Use where local codes permit connecting cabinet-ground  
conductor to neutral wire.  
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer  
can be moved if needed.  
Strip 312" (89 mm) of outer covering from end of cable. Strip  
insulation back 1" (25 mm). If using 3-wire cable with ground wire,  
cut bare wire even with outer covering. Bend ends of wires into a  
hook shape.  
6. Insert tab of terminal block cover into slot of dryer rear panel.  
Secure cover with hold-down screw.  
7. You have completed your electrical connections. Now go to  
“Venting Requirements.”  
3-wire connection: Power Supply Cord  
Use where local codes permit connecting cabinet-ground  
conductor to neutral wire:  
E
B
D
A
C
F
G
When connecting to the terminal block, place the hooked end of  
the wire under the screw of the terminal block (hook facing right),  
squeeze hooked end together and tighten screw, as shown.  
A. 3-wire receptacle (NEMA type 10-30R)  
B. 3-wire plug  
C. Neutral prong  
D. Spade terminals with up turned ends  
E. ¾" (19 mm) UL listed strain relief  
F. Ring terminals  
G. Neutral (white or center wire)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Loosen or remove center silver-colored terminal block screw.  
Optional 3-wire connection  
2. Place the hooked end of the neutral wire (white or center wire)  
of power supply cable under the center screw of terminal  
block (hook facing right). Squeeze hooked end together.  
Tighten screw.  
Use for direct wire or power supply cord where local codes do  
not permit connecting cabinet-ground conductor to neutral  
wire.  
B
C
1. Remove center silver-colored terminal block screw.  
2. Remove neutral ground wire from external ground conductor  
screw. Connect neutral ground wire and the neutral wire (white  
or center wire) of power supply cord/cable under center,  
silver-colored terminal block screw. Tighten screw.  
D
B
C
A
E
A
D
E
A. Neutral ground wire  
B. External ground conductor screw  
C. Center silver-colored terminal block screw  
D. Neutral wire (white or center wire)  
F
¾
E. " (19 mm) UL listed strain relief  
3. Place the hooked ends of the other power supply cable wires  
under the outer terminal block screws (hooks facing right).  
Squeeze hooked ends together. Tighten screws.  
A. External ground conductor screw  
B. Neutral ground wire  
C. Center silver-colored terminal block screw  
D. Neutral wire (white or center wire)  
E. ¾" (19 mm) UL listed strain relief  
F. Grounding path determined by a qualified electrician  
4. Tighten strain relief screw.  
3. Connect the other wires to outer terminal block screws.  
5. Insert tab of terminal block cover into slot of dryer rear panel.  
Tighten screws.  
Secure cover with hold-down screw.  
6. You have completed your electrical connections. Now go to  
“Venting Requirements.”  
4. Tighten strain relief screws.  
5. Insert tab of terminal block cover into slot of dryer rear panel.  
Secure cover with hold-down screw.  
6. Connect a separate copper ground wire from the external  
ground conductor screw to an adequate ground.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Venting Requirements  
Flexible metal vent  
Flexible metal vents are acceptable only if accessible for  
cleaning.  
WARNING  
Flexible metal vent must be fully extended and supported  
when the dryer is in its final location.  
Remove excess flexible metal vent to avoid sagging and  
kinking that may result in reduced airflow and poor  
performance.  
Fire Hazard  
Do not install flexible metal vent in enclosed walls, ceilings,  
or floors.  
Use a heavy metal vent.  
The total length of flexible metal vent should not exceed  
734 ft (2.4 m).  
Do not use a plastic vent.  
Do not use a metal foil vent.  
Elbows  
45° elbows provide better airflow than 90° elbows.  
Failure to follow these instructions can result in death  
or fire.  
WARNING: To reduce the risk of fire, this dryer MUST BE  
EXHAUSTED OUTDOORS.  
IMPORTANT: Observe all governing codes and ordinances.  
The dryer exhaust must not be connected into any gas vent,  
chimney, wall, ceiling, attic, crawlspace, or a concealed space  
of a building.  
Good  
Better  
If using an existing vent system  
Clamps  
Use clamps to seal all joints.  
Clean lint from the entire length of the system and make sure  
exhaust hood is not plugged with lint.  
Exhaust vent must not be connected or secured with screws  
or other fastening devices that extend into the interior of the  
duct and catch lint. Do not use duct tape.  
Replace any plastic or metal foil vent with rigid or flexible  
heavy metal vent.  
Review Vent system chart. Modify existing vent system if  
necessary to achieve the best drying performance. Only rigid  
or flexible metal vent shall be used for exhausting.  
Clamp  
If this is a new vent system  
Exhaust  
Vent material  
Recommended hood styles are shown here.  
Use a heavy metal vent. Do not use plastic or metal foil vent.  
4" (102 mm) heavy metal exhaust vent and clamps must be  
used. DURASAFE™ venting products are recommended.  
B
A
4"  
4"  
102 mm  
(102 mm)  
4"  
(102 mm)  
4" (102 mm) heavy metal exhaust vent  
A. Louvered hood style  
B. Box hood style  
DURASAFE™ vent products can be purchased from your  
dealer or by calling the toll-free number listed on the cover  
of the Dryer User Instructions. For more information, see the  
“Assistance or Service” section of the Dryer User Instructions.  
The angled hood style (shown here) is acceptable.  
4"  
Rigid metal vent  
(102 mm)  
For best drying performance, rigid metal vents are  
recommended.  
Rigid metal vent is recommended to avoid crushing and  
kinking.  
2½"  
(64 mm)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
An exhaust hood should cap the vent to keep rodents and  
insects from entering the home.  
Alternate installations for close clearances  
Venting systems come in many varieties. Select the type best  
for your installation. Two close-clearance installations are shown.  
Refer to the manufacturer’s instructions.  
Exhaust hood must be at least 12" (305 mm) from the ground  
or any object that may be in the path of the exhaust (such as  
flowers, rocks or bushes, snow line, etc.).  
Do not use an exhaust hood with a magnetic latch.  
Improper venting can cause moisture and lint to collect  
indoors, which may result in:  
Moisture damage to woodwork, furniture, paint, wallpaper,  
carpets, etc.  
A
B
Housecleaning problems and health problems.  
A. Over-the-top installation (also available  
with one offset elbow)  
B. Periscope installation  
Plan Vent System  
NOTE: The following kits for close clearance alternate installations  
are available for purchase. Please see the “Assistance or Service”  
section of the Dryer User Instructions.  
Choose your exhaust installation type  
Over-the-Top Installation:  
Recommended exhaust installations  
Typical installations vent the dryer from the rear of the dryer. Other  
installations are possible.  
Part Number 4396028  
Periscope Installation (For use with dryer vent to wall vent  
mismatch):  
B
Part Number 4396037 - 0" (0 mm) to 18" (457 mm) mismatch  
Part Number 4396011 - 18" (457 mm) to 29" (737 mm)  
mismatch  
C
D
Part Number 4396014 - 29" (737 mm) to 50" (1.27 m)  
mismatch  
E
A
Special provisions for mobile home installations  
F
The exhaust vent must be securely fastened to a noncombustible  
portion of the mobile home structure and must not terminate  
beneath the mobile home. Terminate the exhaust vent outside.  
G
B
H
A. Dryer  
B. Elbow  
C. Wall  
E. Clamps  
F. Rigid metal or flexible metal vent  
G. Vent length necessary to connect elbows  
H. Exhaust outlet  
D. Exhaust hood  
Standard exhaust installation with rigid metal or flexible  
metal vent  
Determine vent path  
Select the route that will provide the straightest and most  
direct path outdoors.  
Plan the installation to use the fewest number of elbows and  
turns.  
When using elbows or making turns, allow as much room  
as possible.  
Bend vent gradually to avoid kinking.  
Use the fewest 90° turns possible.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Determine vent length and elbows needed for best  
drying performance  
Install Leveling Legs  
Use the Vent system chart below to determine type of vent  
material and hood combinations acceptable to use.  
WARNING  
NOTE: Do not use vent runs longer than those specified in the  
Vent system chart. Exhaust systems longer than those  
specified will:  
Excessive Weight Hazard  
Use two or more people to move and install dryer.  
Failure to do so can result in back or other injury.  
Shorten the life of the dryer.  
Reduce performance, resulting in longer drying times and  
increased energy usage.  
1. To protect the floor, use a large, flat piece of cardboard from  
the dryer carton. Place cardboard under the entire back side  
of the dryer.  
The Vent system chart provides venting requirements that will help  
to achieve the best drying performance.  
2. Firmly grasp the body of the dryer (not the top or console  
panel). Gently lay the dryer on the cardboard. See illustration.  
Vent system chart  
NOTE: Side and bottom exhaust installations have a 90º turn  
inside the dryer. To determine maximum exhaust length, add one  
90º turn to the chart.  
Number of  
90º turns  
or elbows  
Type of  
vent  
Box or  
louvered  
hoods  
Angled  
hoods  
3. Examine the leveling legs. Find the diamond marking.  
0
1
2
3
4
Rigid metal  
Rigid metal  
Rigid metal  
Rigid metal  
Rigid metal  
64 ft (20 m)  
58 ft (17.7 m)  
48 ft (14.6 m)  
54 ft (16.5 m)  
44 ft (13.4 m) 38 ft (11.6 m)  
35 ft (10.7 m) 29 ft (8.8 m)  
4. Screw the legs into the leg holes by hand. Use a wrench to  
finish turning the legs until the diamond marking is no longer  
visible.  
5. Place a carton corner post from dryer packaging under each  
of the 2 dryer back corners. Stand the dryer up. Slide the  
dryer on the corner posts until it is close to its final location.  
Leave enough room to connect the exhaust vent.  
27 ft (8.2 m)  
21 ft (6.4 m)  
InstallVent System  
Level Dryer  
1. Install exhaust hood. Use caulking compound to seal exterior  
wall opening around exhaust hood.  
Check the levelness of the dryer. Check levelness first side to  
side, then front to back.  
2. Connect vent to exhaust hood. Vent must fit inside exhaust  
hood. Secure vent to exhaust hood with 4" (102 mm) clamp.  
3. Run vent to dryer location. Use the straightest path possible.  
See “Determine vent path” in “Plan Vent System.” Avoid 90º  
turns. Use clamps to seal all joints. Do not use duct tape,  
screws, or other fastening devices that extend into the interior  
of the vent to secure the vent, because they can catch lint.  
If the dryer is not level, prop up the dryer using a wood block.  
Use a wrench to adjust the legs up or down and check again  
for levelness.  
Connect Vent  
1. Using a 4" (102 mm) clamp, connect vent to exhaust outlet  
in dryer. If connecting to existing vent, make sure the vent is  
clean. The dryer vent must fit over the dryer exhaust outlet  
and inside the exhaust hood. Check that the vent is secured  
to exhaust hood with a 4" (102 mm) clamp.  
2. Move dryer into its final location. Do not crush or kink vent.  
3. (On gas models) Check that there are no kinks in the flexible  
gas line.  
4. Once the exhaust vent connection is made, remove the corner  
posts and cardboard.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reverse Door Swing (Optional)  
You can change your door swing from a right-side opening to a  
left-side opening, if desired.  
3. Lift door until top screws in cabinet are in large part of hinge  
slot. Pull door forward off screws. Set door (handle side up) on  
top of dryer. Remove top screws from cabinet.  
Reversible Large Side-Swing Door  
4. Remove screws attaching hinges to door.  
5. Remove screws at top, bottom and side of door (4 screws).  
Holding door over towel on dryer, grasp sides of outer door  
and gently lift to separate it from inner door. Do not pry apart  
with putty knife. Do not pull on door seal or plastic door  
catches.  
6. Be certain to keep cardboard spacer centered between doors.  
Reattach outer door panel to inner door panel so handle is on  
the side where hinges were just removed.  
A
B
D
C
1. Place towel (A) on top of dryer to protect surface.  
7. Attach door hinges to dryer door so that the larger hole is at  
2. Open dryer door. Remove bottom screws from cabinet side of  
hinges (C). Loosen (do not remove) top screws from cabinet  
side of hinges.  
the bottom of the hinge.  
3. Lift door until top screws in cabinet are in large part of hinge  
slot. Pull door forward off screws. Set door on top of dryer.  
Remove top screws from cabinet.  
4. Use a small, flat-blade screwdriver to gently remove 4 hinge  
hole plugs (D) on left side of cabinet. Insert plugs into hinge  
holes on right-hand side of cabinet.  
5. Insert screws into bottom holes on left side of cabinet. Tighten  
screws halfway. Position door so large end of door hinge slot  
is over screws. Slide door up so screws are in bottom of slots.  
Tighten screws. Insert and tighten top screws in hinges.  
8. Remove door strike (E) from cabinet. Use a small, flat-blade  
screwdriver to gently remove 4 hinge hole plugs (F) on left side  
of cabinet. Insert plugs into hinge holes on right side of  
cabinet.  
9. Insert screws into bottom holes on left side of cabinet. Tighten  
screws halfway. Position door so large end of door hinge slot  
is over screws. Slide door up so screws are in bottom of slots.  
Tighten screws. Insert and tighten top screws in hinges.  
6. Close door and check that door strike aligns with door catch  
(B). If needed, slide door catch left or right within slot to adjust  
alignment.  
10. Remove door strike plug (B). Insert the door strike you  
removed in Step 8 into hole and secure with screw. Insert door  
strike plug into original door strike hole and secure with screw.  
11. Close door and check that door strike aligns with door catch  
(C). If it is needed, slide door catch left or right within slot to  
adjust alignment.  
Reversible Super Wide Side-Swing Door  
A
B
C
E
F
D
1. Place towel (A) on top of dryer to protect surface.  
2. Open dryer door. Remove bottom screws from cabinet side of  
hinges (D). Loosen (do not remove) top screws from cabinet  
side of hinges.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Complete Installation  
1. Check that all parts are now installed. If there is an extra part,  
10. Set the dryer on a full heat cycle (not an air cycle) for  
go back through the steps to see which step was skipped.  
2. Check that you have all of your tools.  
20 minutes and start the dryer.  
If the dryer will not start, check the following:  
Controls are set in a running or “On” position.  
Start button has been pushed firmly.  
3. Dispose of/recycle all packaging materials.  
4. Check the dryer’s final location. Be sure the vent is not  
crushed or kinked.  
Dryer is plugged into an outlet and/or electrical supply  
is on.  
5. Check that the dryer is level. See “Level Dryer.”  
6. In the U.S.A.  
Household fuse is intact and tight, or circuit breaker has  
not tripped.  
For power supply cord installation, plug into an outlet.  
For direct wire installation, turn on power.  
Dryer door is closed.  
In Canada  
11. When the dryer has been running for 5 minutes, open the  
dryer door and feel for heat. If you feel heat, cancel cycle and  
close the door.  
Plug into a grounded 4 prong outlet. Turn on power.  
7. Remove the blue protective film on the console and any tape  
remaining on the dryer.  
If you do not feel heat, turn off the dryer and check the  
following:  
8. Read “Dryer Use” in the Dryer User Instructions.  
9. Wipe the dryer drum interior thoroughly with a damp cloth  
There may be 2 household fuses or circuit breakers for the  
dryer. Check that both fuses are intact and tight, or that  
both circuit breakers have not tripped. If there is still no  
heat, contact a qualified technician.  
to remove any dust.  
NOTE: You may notice an odor when the dryer is first heated.  
This odor is common when the heating element is first used.  
The odor will go away.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE  
ÉLECTRIQUE DE 29" (73,7 CM)  
SÉCURITÉ DE LA SÉCHEUSE  
Votre sécurité et celle des autres est très importante.  
Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de  
toujours lire tous les messages de sécurité et de vous y conformer.  
Voici le symbole d’alerte de sécurité.  
Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous  
et à d’autres.  
Tous les messages de sécurité suivront le symbole d’alerte de sécurité et le mot “DANGER” ou  
“AVERTISSEMENT”. Ces mots signifient :  
Risque possible de décès ou de blessure grave si vous ne  
suivez pas immédiatement les instructions.  
DANGER  
Risque possible de décès ou de blessure grave si vous  
ne suivez pas les instructions.  
AVERTISSEMENT  
Tous les messages de sécurité vous diront quel est le danger potentiel et vous disent comment réduire le risque de blessure et  
ce qui peut se produire en cas de non-respect des instructions.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTRUCTIONS D’INSTALLATION  
Un plancher horizontal avec une pente maximale de  
1" (25 mm) sous l’ensemble de la sécheuse. (Si la pente est  
supérieure à 1" [25 mm], installer l’ensemble de pieds longs  
no de pièce 279810.) Si la sécheuse n’est pas d’aplomb,  
le linge peut ne pas culbuter convenablement et les  
programmes commandés par des détecteurs automatiques  
peuvent ne pas fonctionner correctement.  
Outillage et pièces  
Rassembler les outils et pièces nécessaires avant de commencer  
l’installation. Lire et suivre les instructions fournies avec les outils  
indiqués ici.  
Tournevis à lame plate  
Tournevis Phillips no 2  
Niveau  
Clapets d’évacuation  
Ne pas faire fonctionner la sécheuse à une température inférieure  
à 45ºF (7ºC). À des températures inférieures, la sécheuse risque  
de ne plus s’arrêter à la fin d’un programme automatique. Les  
temps de séchage risquent alors d’augmenter.  
La sécheuse ne doit pas être installée ou remisée dans un endroit  
où elle sera exposée à l’eau et/ou aux intempéries.  
Clé à molette avec  
Pistolet à calfeutrage et  
composé de calfeutrage  
(pour l’installation d’un  
nouveau conduit  
ouverture jusqu’à 1"  
(25 mm) ou clé à douille  
hexagonale (pour ajuster  
les pieds de la sécheuse)  
d’évacuation)  
Cisaille de ferblantier  
(pour l’installation d’un  
nouveau conduit  
Mètre ruban  
Vérifier les règlements locaux. Certains codes limitent ou  
n’autorisent pas l’installation des sécheuses dans un garage,  
un placard, une maison mobile ou une chambre à coucher.  
Communiquer avec l’inspecteur des bâtiments local.  
d'évacuation)  
Pièces fournies :  
Dégagements de séparation à respecter  
Retirer le sachet de pièces du tambour de la sécheuse. Vérifier  
L’emplacement doit être assez grand pour permettre d’ouvrir  
que toutes les pièces de la liste sont présentes.  
complètement la porte de la sécheuse.  
Dimensions de la sécheuse  
22¾"  
15¼"  
(578 mm)  
(387 mm)  
433  
"
(1102 8mm)  
4 pieds de nivellement  
433  
"
8  
(1102 mm)  
Pièces nécessaires :  
Consulter les codes locaux, vérifier l’alimentation électrique  
et le circuit d’évacuation existants, et consulter les sections  
“Spécifications électriques” et “Exigences concernant  
l’évacuation” avant d’acheter les pièces nécessaires.  
Les installations pour maison mobile nécessitent un système  
d'évacuation en métal qui peut être acheté chez le marchand  
chez qui vous avez acheté votre sécheuse. Pour plus  
d'information, veuillez consulter la section “Assistance ou service”  
des “Instructions d'utilisation de la sécheuse”.  
*26"  
*27¾"  
(660 mm)  
(705 mm)  
29"  
29"  
(737 mm)  
(737 mm)  
A
B
22¾"  
(578 mm)  
433  
8
"
433  
"
(11028mm)  
(1102 mm)  
Exigences d’emplacement  
13¾"  
(349 mm)  
*27¾"  
*27¾"  
(705 mm)  
(705 mm)  
29"  
29"  
(737 mm)  
(737 mm)  
D
C
A. Porte à pivotement latéral à petite ouverture  
B. Porte à pivotement latéral à grande ouverture  
C. Porte à pivotement latéral à large ouverture  
D. Porte rabattable à large ouverture  
*La plupart des installations requièrent un espace minimum de  
5" (127 mm) derrière la sécheuse pour le conduit d’évacuation  
avec coude. Voir “Exigences concernant l'évacuation”.  
Espacement minimum pour une installation dans un  
encastrement ou dans un placard  
On recommande les dimensions d'espacement suivantes pour cette  
sécheuse. Cette sécheuse a été testée pour une installation avec  
dégagement de 0" (0 mm) sur les côtés et à l'arrière. L'espacement  
recommandé doit être considéré pour les raisons suivantes :  
On prévoira un peu plus d’espace pour faciliter l’installation  
et l’entretien.  
Un espace supplémentaire peut être requis pour les moulures  
de porte et de plancher et pour les plinthes.  
Un espace supplémentaire de tous les côtés de la sécheuse  
est recommandé pour réduire le transfert du bruit.  
Si une porte de placard est installée (pour une installation  
encastrée), on doit prévoir des orifices d’entrée d’air en haut  
et en bas de la porte. Les portes à claire-voie offrant une  
surface équivalente de passage de l’air sont acceptables.  
On a besoin de  
Un emplacement avec un conduit d’évacuation à proximité.  
Voir “Exigences concernant l'évacuation”.  
Un circuit séparé de 30 ampères.  
Une prise électrique avec liaison à la terre située à moins  
de 2 pi (610 mm) de l’un des côtés de la sécheuse. Voir  
“Spécifications électriques”.  
Un plancher robuste capable de supporter un poids total  
(sécheuse et charge) de 200 lb (90,7 kg). Le poids combiné  
d’un appareil voisin doit également être pris en compte.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Il faut aussi prendre en compte l’espace requis entre les  
appareils voisins.  
Alimenter l’appareil uniquement par un circuit monophasé  
de 115/230 volts CA, 60 Hz à 4 fils, sur un circuit séparé de  
30 ampères, fusionné aux deux extrémités de la ligne. On  
recommande l’emploi d’un fusible temporisé ou disjoncteur.  
On recommande également que cet appareil soit alimenté par  
un circuit indépendant.  
Un espacement supplémentaire est requis si l’air est évacué  
à l'arrière de la sécheuse sur le côté gauche ou droit.  
3"*  
(76 mm)  
14" max*  
(356 mm)  
Cette sécheuse est équipée d’un cordon électrique  
homologué par la CSA International à introduire dans  
une prise murale standard 14-30R. Le cordon mesure 5 pi  
(1,52 m). Veiller à ce que la prise murale se trouve à proximité  
de l’emplacement définitif de la sécheuse.  
48 po2  
*
(310 cm2 )  
18"*  
(457 mm)  
24 po2  
*
3"*  
(76 mm)  
(155 cm2 )  
27¾"  
(705 mm) (127 mm)  
5"*  
1"  
(25 mm)  
29"  
(737 mm)  
1"  
(25 mm) (25 mm)  
1"*  
C
A
B
Prise murale à 4 fils 14-30R  
A. Encastrement  
B. Vue latérale – placard ou endroit exigu  
C. Porte du placard avec orifices d’entrée d’air  
Ne pas utiliser de cordon de rallonge.  
Si on utilise un cordon d’alimentation de rechange, il est  
recommandé d’utiliser le cordon d’alimentation de rechange  
numéro de pièce 3394208. Pour plus d’information, veuillez  
consulter les numéros de service qui se trouvent dans les  
Instructions d’utilisation de la sécheuse.  
*Espacement requis  
Exigences additionnelles concernant l’installation dans  
une maison mobile  
Cette sécheuse peut être installée dans une maison mobile.  
Linstallation doit satisfaire les critères de la Norme de  
construction et de sécurité des habitations préfabriquées Titre 24  
CFR, partie 3280 (anciennement Norme fédérale de construction  
et de sécurité des habitations préfabriquées, Titre 24 HUD, partie  
280) ou de la Norme canadienne des habitations préfabriquées,  
CAN/CSA-Z240MH.  
INSTRUCTIONS DE LIAISON À LA TERRE  
Pour une sécheuse reliée à la terre et connectée par  
un cordon :  
Cette sécheuse doit être reliée à la terre. En cas de mauvais  
fonctionnement ou de panne, la liaison à la terre réduira le  
risque de choc électrique en offrant au courant électrique un  
acheminement d'évacuation de moindre résistance. Cette  
sécheuse est alimentée par un cordon électrique comportant  
un conducteur relié à la terre et une fiche de branchement  
munie d'une broche de liaison à la terre. La fiche doit être  
branchée sur une prise appropriée qui est bien installée et  
reliée à la terre conformément à tous les codes et règlements  
locaux.  
L’installation dans une maison mobile exige :  
Un système d’évacuation en métal qui peut être acheté chez  
votre marchand.  
Il faut prendre des dispositions spéciales pour l’apport d’air de  
l’extérieur dans la sécheuse lors d’une installation dans une  
maison mobile. La surface de toute ouverture pour l’apport  
d’air extérieur (telle qu’une fenêtre à proximité) devrait être au  
moins deux fois plus grande que l’ouverture de décharge de la  
sécheuse.  
AVERTISSEMENT : Le raccordement incorrect de  
cet appareil au conducteur de liaison à la terre peut susciter  
un risque de choc électrique. En cas de doute quant à la  
qualité de liaison à la terre de la sécheuse, consulter un  
électricien ou un technicien ou un personnel qualifié. Ne pas  
modifier la fiche de branchement fournie avec la sécheuse;  
si la fiche ne correspond pas à la configuration de la prise de  
courant, demander à un électricien qualifié d'installer une  
prise de courant appropriée.  
Spécifications électriques - Canada  
AVERTISSEMENT  
CONSERVEZ CES INSTRUCTIONS  
Risque de choc électrique  
Brancher sur une prise à 4 alvéoles reliée à la terre.  
Le non-respect de cette instruction peut causer  
un décès ou un choc électrique.  
C’est à l’utilisateur qu’incombe la responsabilité de  
Communiquer avec un électricien qualifié.  
S’assurer que les connexions électriques sont adéquates et  
conformes au Code canadien d’électricité, C22.1 - dernière  
édition et à tous les codes locaux. Pour obtenir un exemplaire  
de la norme des codes ci-dessus, contacter : Association  
canadienne de normalisation, 178 Rexdale Blvd., Toronto, ON  
M9W 1R3 CANADA.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Exigences concernant l’évacuation  
Conduit métallique rigide  
Pour un meilleur rendement de séchage, on recommande  
d'utiliser des conduits métalliques rigides.  
AVERTISSEMENT  
On recommande d'utiliser un conduit métallique rigide pour  
réduire les risques d'écrasement et de déformation.  
Conduit métallique flexible  
Les conduits métalliques flexibles sont acceptables  
seulement dans la mesure où ils sont accessibles en vue du  
nettoyage.  
Risque d’incendie  
Un conduit métallique flexible doit être totalement déployé et  
soutenu lorsque la sécheuse est à sa position finale.  
Utiliser un conduit d’évacuation en métal lourd.  
Ne pas utiliser un conduit d’évacuation en plastique.  
Enlever tout excès de conduit flexible pour éviter tout  
affaissement ou déformation susceptible de réduire la  
capacité d'évacuation et le rendement.  
Ne pas utiliser un conduit d’évacuation en feuille  
de métal.  
Ne pas installer le conduit métallique flexible dans les cavités  
fermées des murs, plafonds ou planchers.  
Le non-respect de ces instructions peut causer  
un décès ou un incendie.  
La longueur totale du conduit métallique flexible ne doit pas  
dépasser 734 pi (2,4 m).  
AVERTISSEMENT : Pour réduire le risque d'incendie,  
Coudes  
cette sécheuse doit ÉVACUER L'AIR À L'EXTÉRIEUR.  
Les coudes à 45° permettent une meilleure circulation de l'air  
que les coudes à 90°.  
IMPORTANT : Observer les dispositions de tous les codes et  
règlements en vigueur.  
Le conduit d'évacuation de la sécheuse ne doit pas être connecté  
à une évacuation de gaz, une cheminée, un mur, un plafond, un  
grenier, un vide de sanitaire ou un vide de construction.  
En cas d'utilisation du système d'évacuation existant  
Éliminer la charpie sur toute la longueur du système et veiller  
à ce que le clapet de décharge ne soit pas obstrué par une  
accumulation de charpie.  
Bon  
Meilleur  
Remplacer tout conduit de plastique ou de feuille métallique  
par un conduit de métal lourd rigide ou flexible.  
Brides de serrage  
Utiliser des brides pour sceller tous les joints.  
Examiner le tableau de longueur du conduit d'évacuation.  
Apporter les modifications nécessaires au système  
d'évacuation pour atteindre le meilleur rendement de  
séchage. Seul un conduit métallique rigide ou flexible  
doit être utilisé pour l’évacuation.  
Le conduit d'évacuation ne doit pas être connecté ou fixé  
avec des vis ou avec tout autre dispositif de serrage qui se  
prolonge à l'intérieur du conduit et peuvent retenir la charpie.  
Ne pas utiliser de ruban adhésif pour conduit.  
En cas de nouveau système d'évacuation  
Matériel pour l'évacuation  
Utiliser un conduit d'évacuation en métal lourd. Ne pas utiliser  
un conduit de plastique ou en feuille métallique.  
Bride de serrage  
Utiliser un conduit d'évacuation en métal lourd de 4" (102 mm)  
et des brides de serrage. Les produits d'évacuation  
DURASAFE™ sont recommandés.  
Évacuation  
Les styles de clapets recommandés sont illustrés ci-dessous.  
B
A
4"  
102 mm  
4"  
(102 mm)  
Conduit d'évacuation en métal lourd de 4" (102 mm)  
4"  
(102 mm)  
Les produits d’évacuation DURASAFE™ peuvent être achetés  
chez votre marchand ou en composant le numéro de  
téléphone sans frais indiqué sur la page de couverture des  
Instructions pour l’utilisateur de la sécheuse. Pour plus de  
renseignements, voir la section “Assistance ou service”  
service" des “Instructions d'utilisation de la sécheuse”.  
A. Clapet à persiennes  
B. Clapet de type boîte  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Le clapet incliné de type boîte ci-dessous est acceptable.  
Installationsstandarddu conduit d’évacuation à l’aide d’un  
conduit métallique rigide ou flexible.  
4"  
(102 mm)  
2½"  
(64 mm)  
Terminer le conduit d'évacuation par un clapet de décharge  
pour empêcher les rongeurs et insectes d'entrer dans  
l'habitation.  
Le clapet de décharge doit être situé à au moins 12" (305 mm)  
au-dessus du sol ou de tout autre objet susceptible de se  
trouver sur le trajet de l'air humide rejeté (par exemple, fleurs,  
roches ou arbustes, limite de la neige, etc.)  
Autres installations où le dégagement est réduit  
Il existe de nombreux types de systèmes d’évacuation. Choisir  
le type qui convient le mieux à l’installation. Deux installations  
à dégagement réduit sont illustrées. Voir les instructions  
du fabricant.  
Ne pas utiliser un clapet d'évacuation à fermeture  
magnétique.  
Une mauvaise évacuation de l'air peut causer de  
l'humidité et une accumulation de charpie à l'intérieur de  
la maison, ce qui peut provoquer :  
Dommages par l'humidité aux boiseries, meubles, peinture,  
papier-peint, tapis, etc.  
Problèmes de nettoyage dans la maison et problèmes  
de santé.  
A
B
A. Installation au-dessus de la sécheuse (aussi disponible  
avec un coude décalé)  
B. Installation de périscope  
Planification du système d’évacuation  
Choisir un type de système d’évacuation  
REMARQUE : On peut acheter les trousses suivantes pour les  
installations où le dégagement est réduit. Veuillez consulter la  
section “Assistance ou service” dans les Instructions pour  
l’utilisateur de la sécheuse.  
Installations d’évacuation recommandées  
Les installations typiques consistent à acheminer le conduit  
d’évacuation à l’arrière de la sécheuse. D'autres installations sont  
possibles.  
Installation au-dessus de la sécheuse :  
Pièce numéro 4396028  
B
Installation de périscope (pour l’utilisation en cas de non-  
concordance de la bouche de décharge de la sécheuse avec  
le clapet) :  
C
D
Pièce numéro 4396037 - 0" (0 mm) à 18" (457 mm)  
de décalage  
E
A
Pièce numéro 4396011 - 18" (457 mm) à 29" (737 mm)  
de décalage  
F
G
Pièce numéro 4396014 - 29" (737 mm) à 50" (1,27 m)  
de décalage  
B
Dispositions spéciales pour les installations dans une  
maison mobile  
H
Le système d'évacuation doit être solidement fixé à une section  
non combustible de la structure de la maison mobile et ne doit  
pas se terminer en-dessous de la maison mobile. Faire en sorte  
que le système d'évacuation se termine à l'extérieur.  
A. Sécheuse  
B. Coude  
C. Mur  
D. Clapet de décharge  
E. Brides  
F. Conduit métallique rigide ou flexible  
G. Longueur de conduit nécessaire pour  
raccorder les coudes  
H. Bouche de décharge  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Déterminer l'itinéraire d'acheminement du conduit  
Installation du système d’évacuation  
1. Installer le clapet d’évacuation. Utiliser du composé de  
calfeutrage pour sceller l’ouverture murale à l’extérieur autour  
du clapet d’évacuation.  
Choisir l'itinéraire d'acheminement vers l'extérieur qui sera le  
plus direct et le plus rectiligne.  
Planifier l'installation pour introduire le nombre minimal de  
coudes et de changements de direction.  
2. Raccorder le conduit d’évacuation au clapet. Le conduit doit  
être inséré à l’intérieur du clapet. Fixer ensemble le conduit et  
le clapet avec une bride de serrage de 4" (102 mm).  
Si des coudes ou des changements de direction sont utilisés,  
prévoir autant d'espace que possible.  
3. Acheminer le conduit d’évacuation jusqu’à l’emplacement de  
la sécheuse. Utiliser l’itinéraire le plus rectiligne possible. Voir  
“Déterminer l'itinéraire d'acheminement du conduit” dans  
“Planification du système d'évacuation”. Éviter les  
changements de direction à 90º. Utiliser des brides de serrage  
pour sceller tous les joints. Ne pas utiliser de ruban adhésif  
pour conduit, des vis ou autres dispositifs de fixation qui se  
prolongent à l’intérieur du conduit pour fixer celui-ci et qui  
peuvent retenir la charpie.  
Plier le conduit graduellement pour éviter de le déformer.  
Utiliser le moins possible de changements de direction à 90°.  
Déterminer la longueur du conduit et les coudes  
nécessaires pour la meilleure performance de séchage  
Utiliser le tableau des systèmes d'évacuation ci-dessous pour  
déterminer le type de matériel à utiliser pour le conduit et les  
combinaisons de clapet acceptables.  
Installation des pieds de nivellement  
REMARQUE : Ne pas utiliser un conduit de longueur  
supérieure à la valeur spécifiée dans le tableau des systèmes  
d'évacuation. Si la longueur du circuit est supérieure à la  
valeur spécifiée dans le tableau, on observera :  
AVERTISSEMENT  
Une réduction de la longévité de la sécheuse.  
Risque du poids excessif  
Une réduction du rendement, avec temps de séchage  
plus longs et une plus grande consommation d'énergie.  
Utiliser deux ou plus de personnes pour déplacer et  
installer la sécheuse.  
Le tableau des systèmes d'évacuation fournit les exigences  
d'évacuation qui vous aideront à atteindre la meilleure  
performance de séchage.  
Le non-respect de cette instruction peut causer  
une blessure au dos ou d’autre blessure.  
Tableau des systèmes d'évacuation  
1. Pour protéger le sol, utiliser un grand morceau de l’emballage  
en carton de la sécheuse. Placer le carton sous le bord arrière  
de la sécheuse.  
2. Saisir fermement la sécheuse par la caisse (ni par le dessus ni  
par le panneau de commande). Déposer délicatement la  
sécheuse sur le carton. Voir l’illustration.  
REMARQUE : Les installations d’évacuation du conduit par le  
côté ou par le bas comportent un changement de direction à 90º  
à l’intérieur de la sécheuse. Pour établir la longueur maximale du  
conduit, ajouter un changement de direction à 90º au tableau.  
Nombre de  
Type de  
Clapets de  
typeboîteou inclinés  
à persiennes  
Clapets  
changements conduit  
de direction  
à 90° ou  
coudes  
0
1
2
3
4
Métallique  
64 pi (20 m)  
58 pi (17,7 m)  
rigide  
3. Examiner les pieds de nivellement. Trouver le symbole de  
repérage (losange).  
Métallique  
rigide  
54 pi (16,5 m) 48 pi (14,6 m)  
44 pi (13,4 m) 38 pi (11,6 m)  
35 pi (10,7 m) 29 pi (8,8 m)  
Métallique  
rigide  
4. Engager manuellement les pieds dans les trous. Utiliser une  
clé à molette pour visser les pieds jusqu'à ce que le symbole  
de repérage (losange) ne soit plus visible.  
5. Placer une cornière de carton provenant de l’emballage de  
la sécheuse sous chacun des 2 coins arrière de la sécheuse.  
Redresser la sécheuse. Faire glisser la sécheuse sur les  
cornières près de son emplacement définitif. Laisser  
suffisamment d’espace pour connecter le conduit  
d’évacuation.  
Métallique  
rigide  
Métallique  
rigide  
27 pi (8,2 m)  
21 pi (6,4 m)  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Soulever la porte suffisamment pour que les vis supérieures  
de la caisse se trouvent dans la partie élargie des trous des  
charnières. Tirer la porte vers l’avant pour la dégager des vis.  
Placer la porte sur le dessus de la sécheuse. Ôter les vis  
supérieures de la caisse.  
Mise à niveau de la sécheuse  
Contrôler l’aplomb de la sécheuse. Contrôler l’aplomb tout  
d’abord transversalement, puis dans le sens avant/arrière.  
4. Utiliser un petit tournevis à lame plate pour ôter  
soigneusement quatre bouchons d’obturation (D) du côté  
gauche de la caisse. Insérer les bouchons dans les trous de  
charnières du côté droit de la caisse.  
5. Insérer les vis dans les trous inférieurs du côté gauche de la  
caisse. Serrer les vis à moitié. Placer la porte de telle sorte que  
la partie élargie du trou de charnière se trouve au-dessus des  
vis. Glisser la porte vers le haut de sorte que les vis se  
trouvent au bas des fentes. Serrer les vis. Insérer les vis  
supérieures dans les charnières et les serrer.  
Si la sécheuse n’est pas de niveau, la déposer sur un bloc de  
bois. Utiliser une clé à molette pour ajuster les pieds vers le haut  
ou vers le bas, et vérifier à nouveau si elle est de niveau.  
Raccordement du conduit d’évacuation  
1. À l’aide d’une bride de serrage de 4" (102 mm), relier le  
conduit d’évacuation à la bouche d’évacuation de la  
sécheuse. Si on utilise un système d’évacuation existant,  
s’assurer qu’il est propre. Le conduit d’évacuation de la  
sécheuse doit être fixé sur la bouche d’évacuation de la  
sécheuse et dans le clapet d’évacuation. S’assurer que le  
conduit d’évacuation est fixé au clapet d’évacuation à l’aide  
d’une bride de serrage de 4" (102 mm).  
6. Fermer la porte et vérifier que la gâche de la porte est alignée  
avec le loquet (B) de la porte. Au besoin, déplacer la gâche de  
la porte vers la gauche ou la droite dans son logement pour  
ajuster l'alignement.  
2. Placer la sécheuse à son emplacement final. Ne pas écraser  
Porte réversible extra-large à pivotement latéral  
ni déformer le conduit d’évacuation.  
3. (Sur les modèles à gaz) Vérifier que le tuyau de gaz flexible  
A
B
n'est pas déformé ou écrasé.  
4. Une fois que le conduit d’évacuation est raccordé, retirer les  
cornières et le carton.  
C
E
Inversion du sens d’ouverture de la porte  
(facultatif)  
On peut changer l’ouverture de la porte du côté droit au côté  
gauche si désiré.  
F
D
Grande porte réversible à pivotement latéral  
A
1. Placer une serviette (A) sur la sécheuse pour protéger la  
surface.  
2. Ouvrir la porte de la sécheuse. Ôter les vis inférieures fixant  
les charnières (D) sur la caisse. Desserrer (sans les ôter) les vis  
supérieures fixant les charnières sur la caisse.  
B
3. Soulever la porte suffisamment pour que les vis supérieures  
de la caisse se trouvent dans la partie élargie des trous des  
charnières. Tirer la porte vers l’avant pour la dégager des vis.  
Placer la porte (poignée vers le haut) sur le dessus de la  
sécheuse. Ôter les vis supérieures de la caisse.  
D
C
4. Enlever les vis qui fixent les charnières sur la porte.  
5. Enlever les vis au sommet, en bas et sur le côté de la porte  
(4 vis). En tenant la porte au-dessus de la serviette sur la  
sécheuse, saisir les côtés de la section externe de la porte et  
soulever prudemment pour la séparer de la section interne de  
la porte. Ne pas essayer de séparer les deux sections avec un  
couteau à mastic. Ne pas tirer sur le joint de la porte ou sur les  
loquets de plastique de la porte.  
1. Placer une serviette (A) sur la sécheuse pour protéger la  
surface.  
2. Ouvrir la porte de la sécheuse. Ôter les vis inférieures fixant  
les charnières (C) sur la caisse. Desserrer (sans les ôter) les vis  
supérieures fixant les charnières sur la caisse.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Veiller à maintenir la plaque de carton d’espacement centrée  
entre les deux sections de la porte. Réassembler la section  
externe et la section interne de la porte de telle manière que la  
poignée soit orientée du côté où les charnières viennent d’être  
enlevées.  
9. Insérer les vis dans les trous inférieurs du côté gauche de la  
caisse. Serrer les vis à moitié. Placer la porte de telle sorte que  
la partie élargie du trou de charnière se trouve au-dessus des  
vis. Glisser la porte vers le haut de telle sorte que les vis se  
trouvent au bas des fentes. Serrer les vis. Insérer les vis  
supérieures dans les charnières et les serrer.  
7. Fixer les charnières de porte à la porte de la sécheuse de  
façon à ce que le trou le plus gros se trouve dans la partie  
inférieure de la charnière.  
10. Enlever le bouchon d’obturation de la gâche de la porte (B).  
Insérer dans le trou la gâche qui a été enlevée à l’étape 8; fixer  
la gâche avec la vis. Insérer le bouchon d’obturation dans le  
trou d’où la gâche avait été initialement extraite; fixer le  
bouchon avec la vis.  
11. Fermer la porte; vérifier que la gâche de la porte est alignée  
avec le loquet (C). Au besoin, déplacer la gâche de la porte  
vers la gauche ou vers la droite dans son logement pour  
ajuster l’alignement.  
8. Enlever la gâche de la porte (E) de la caisse. Utiliser un petit  
tournevis à lame plate pour ôter soigneusement 4 bouchons  
d’obturation (F) du côté gauche de la caisse. Insérer les  
bouchons dans les trous de charnière du côté droit de la  
caisse.  
Achever l’installation  
1. Vérifier que toutes les pièces sont installées. S’il reste une  
pièce, passer en revue les différentes étapes pour découvrir  
laquelle aurait été oubliée.  
10. Régler la sécheuse sur un programme de séchage complet  
(pas le programme de séchage sans chaleur) de 20 minutes et  
mettre la sécheuse en marche.  
2. S’assurer d’avoir tout l’outillage nécessaire.  
3. Jeter ou recycler tout le matériel d’emballage.  
Si la sécheuse ne démarre pas, vérifier ce qui suit :  
Les commandes sont réglées à la position de marche ou  
“On”.  
4. Vérifier l’emplacement définitif de la sécheuse. S’assurer que  
le conduit d’évacuation n’est pas écrasé ou déformé.  
Le bouton Start (mise en marche) a été enfoncé fermement  
.
5. Vérifier que la sécheuse est de niveau. Voir “Mise à niveau de  
La sécheuse est branchée sur une prise reliée à la terre et  
l'alimentation électrique est connectée.  
la sécheuse”.  
6. Brancher sur une prise à 4 alvéoles reliée à la terre. Mettre le  
Les fusibles du domicile sont intacts et serrés, ou le  
disjoncteur n’est pas déclenché.  
courant.  
7. Retirer la pellicule de protection bleue sur le panneau de  
La porte de la sécheuse est fermée.  
commande et le ruban resté sur la sécheuse.  
8. Lire “Utilisation de la sécheuse” dans les Instructions pour  
11. Après 5 minutes de fonctionnement, ouvrir la porte de la  
sécheuse et voir s’il y a de la chaleur. En cas de chaleur,  
annuler le programme et fermer la porte.  
l’utilisateur de la sécheuse.  
9. Essuyer soigneusement le tambour de la sécheuse avec un  
chiffon humide pour éliminer toute trace de poussière.  
Si aucune chaleur n'est perceptible, désactiver la  
sécheuse et vérifier ce qui suit :  
Il peut y avoir 2 fusibles ou disjoncteurs pour la sécheuse.  
Vérifier que les 2 fusibles sont intacts et serrés ou que les  
deux disjoncteurs ne se sont pas déclenchés. S’il n’y a  
toujours pas de chaleur, contacter un technicien qualifié.  
REMARQUE : Il est possible que la sécheuse dégage une  
odeur lors du chauffage initial. Cette odeur est normale lorsque  
l’élément chauffant est utilisé pour la première fois. L’odeur  
disparaîtra.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
W10150612B  
SP PN W10150613B  
11/08  
Printed in U.S.A.  
Imprime aux É.-U.  
© 2008. All rights reserved.  
Tous droits réservés.  
TM DURASAFE is a trademark of Whirlpool, U.S.A., Whirlpool Canada LP Licensee in Canada  
TM DURASAFE est une marque de commerce de Whirlpool, U.S.A., Emploi licencié par Whirlpool Canada LP au Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Home Security System 3CRWE825075A User Manual
3M Home Theater System S55 User Manual
Acnodes Heat Pump Q5RF SERIES User Manual
Advantech Computer Monitor PPC 150 User Manual
AEG Switch MBS 2000 User Manual
Agri Fab Lawn Aerator 45 0381 User Manual
Agri Fab Lawn Mower Accessory 45 02932 User Manual
Air King Fan 2EKZ7 User Manual
American Standard Bathroom Aids 018 User Manual
Audiovox Automobile Battery Charger PRO 9056TW User Manual