Tumble Dryer
OPL Electronic Control
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. 70444901R3
July 2011
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction.........................................................................................
3
Table of
Contents
Preliminary Information....................................................................
6
8
Operation Modes .................................................................................. 10
Idle Mode......................................................................................... 10
Run Mode......................................................................................... 10
Error Mode....................................................................................... 10
Machine Cycle Definition and Operation......................................... 12
To Start a Cycle .................................................................................... 12
Entering the Manual Mode................................................................ 13
Collecting Audit Information ............................................................ 25
Manual Reset....................................................................................... 26
© Copyright 2011, Alliance Laundry Systems LLC
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any
means without the expressed written consent of the publisher.
70444901
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing Machine and Electronic Control Functions........................ 27
Machine Errors................................................................................... 34
Rotation Sensor Error ........................................................................... 35
Error Codes......................................................................................... 37
Communications Mode ...................................................................... 39
Cycle Charts........................................................................................ 40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Model Identification
Gas
Steam/Thermal Oil
Electric
CHD25G2-CA025L
CHD25G2-CA025N
CHD25G2-CT025L
CHD25G2-CT025N
CHD25G2-CU025L
DR25G2-BU025L
HA025L
HA025N
HT025L
HT025N
HU025L
HU025N
IPD25G2-IT025N
IPD25G2-IT025L
SA025L
ST025L CHD25S2-CU025S
ST025N CHD25S2-CT025S
SU025L DR25S2-BT025S
SU025N DR25S2-BU025S
UA025L HT025S
UA025N HU025S
UT025L IPD25S2-IT025S
UT025N ST025S
CHD25E2-CT025E
CHD25E2-CU025E
DR25E2-BT025E
DR25E2-BU025E
HT025E
HU025E
IPD25E2-IT025E
ST025E
25
CHD25G2-CU025N
Pound
DR25G2-BA025L
DR25G2-BA025N
DR25G2-BT025N
DR25G2-BT025L
DR25G2-BU025N
UU025L SU025S
UU025N UT025S
SU025E
UT025E
UU025E
SA025N
UU025S
CHD30G2-CA030L
CHD30G2-CA030N
CHD30G2-CT030L
CHD30G2-CT030N
CHD30G2-CU030L
DR30G2-BU030L
SA030L
SA030N
HA030L
HA030N
ST030D CHD30S2-CU030S
ST030L CHD30S2-CT030S
ST030N DR30S2-BT030S
SU030L DR30S2-BU030S
SU030N HT030S
CHD30E2-CU030E
CHD30E2-CT030E
DR30E2-BT030E
DR30E2-BU030E
HT030E
CHD30G2-CU030N
DR30G2-BA030N
DR30G2-BA030L
DR30G2-BT030D
DR30G2-BT030L
DR30G2-BT030N
DR30G2-BU030N
HT030D
HT030L
HT030N
HU030L
HU030N
IPD30G2-IT030N
IPD30G2-IT030L
UA030L HU030S
UA030N IPD30S2-IT030S
UT030L ST030S
UT030N SU030S
UU030L UT030S
HU030E
IPD30E2-IT030E
ST030E
SU030E
UT030E
30
Pound
UU030N UU030S
UU030E
CHD30STG2-CAT30L DRST30G2-BTT30N HUT30L CHD30STS2-CUT30S
CHD30STG2-CAT30N DRST30G2-BUT30L HUT30N CHD30STS2-CTT30S
CHD30STG2-CTT30L DRST30G2-BUT30N SAT30L DRST30S2-BUT30S
CHD30STE2-CUT30E
CHD30STE2-CTT30E
DRST30E2-BUT30E
DRST30E2-BTT30E
HTT30E
HUT30E
IPD30STE2-ITT30E
STT30E
CHD30STG2-CTT30N HAT30L
CHD30STG2-CUT30L HAT30N
CHD30STG2-CUT30N HTT30D
DRST30G2-BAT30L HTT30L
DRST30G2-BAT30N HTT30N
SAT30N DRST30S2-BTT30S
STT30D HTT30S
STT30L HUT30S
STT30N IPD30STS2-ITT30S
SUT30L STT30S
30
Pound
Stacked
DRST30G2-BTT30D IPD30STG2-ITT30N SUT30N SUT30S
DRST30G2-BTT30L IPD30STG2-ITT30L
SUT30E
CHD35G2-CA035L
CHD35G2-CA035N
CHD35G2-CT035L
CHD35G2-CT035N
CHD35G2-CU035L
CHD35G2-CU035N
DR35G2-BA035N
DR35G2-BA035L
DR35G2-BT035N
DR35G2-BT035L
DR35G2-BU035N
DR35G2-BU035L
HA035L
HA035N
HT035L
HT035N
HU035L
HU035N
IPD35G2-IT035L
IPD35G2-IT035N
SA035L
ST035L CHD35S2-CU035S
ST035N CHD35S2-CT035S
SU035L DR35S2-BT035S
SU035N DR35S2-BU035S
UA035L HT035S
UA035N HU035S
UT035L IPD35S2-IT035S
UT035N ST035S
CHD35E2-CT035E
CHD35E2-CU035E
DR35E2-BT035E
DR35E2-BU035E
HT035E
HU035E
IPD35E2-IT035E
ST035E
35
Pound
UU035L SU035S
UU035N UT035S
SU035E
UT035E
UU035E
SA035N
UU035S
Models continued on next page.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
(Continued)
Gas
Steam/Thermal Oil
Electric
CTT45L
CTT45N
DRST45G2-BAT45L HTT45D
DRST45G2-BAT45N HTT45L
DRST45G2-BTT45D HTT45N
HAT45L
HAT45N
SAT45L
SAT45N
STT45D
STT45L
STT45N
SUT45L
SUT45N
45
Pound
Stacked
Not Applicable
Not Applicable
DRST45G2-BTT45L HUT45L
DRST45G2-BTT45N HUT45N
DRST45G2-BUT45L IPD45STG2-ITT45N
DRST45G2-BUT45N IPD45STG2-ITT45L
CA050L
CA050N
CT050L
CT050N
CU050L
CU050N
DR55G2-BA050N
DR55G2-BA050L
DR55G2-BT050D
DR55G2-BT050L
DR55G2-BT050N
DR55G2-BU050N
DR55G2-BU050L
HA050L
HA050N
HT050D
HT050L
HT050N
HU050L
HU050N
ST050D CT050S
ST050L CT050T
ST050N CU050S
SU050L CU050T
SU050N DR55S2-BT050T SU050S
UA050L DR55S2-BT050S SU050T
UA050N DR55S2-BU050S UT050S
UT050L DR55S2-BU050T UT050T
UT050N HT050S
UU050L HT050T
UU050N HU050S
HU050T
IPD50S2-IT050S CT050E
IPD50S2-IT050T CU050E
ST050S
ST050T
DR55E2-BT050E
DR55E2-BU050E
HT050E
HU050E
IPD50E2-IT050E
ST050E
50
Pound
IPD50G2-IT050N
IPD50G2-IT050L
SA050L
UU050S
UU050T
SU050E
UT050E
UU050E
SA050N
CA055L
CA055N
CT055L
CT055N
CU055L
CU055N
HA055L
HA055N
HT055D
HT055L
HT055N
HU055L
HU055N
IPD55G2-IT055N
IPD55G2-IT055L
SA055L
SA055N
ST055D
HU055L
HU055N
SU055L
SU055N
UA055L
UA055N
UT055L
UT055N
UU055L
UU055N
CT055E
CU055E
HT055E
HU055E
IPD55E2-IT055E
ST055E
SU055E
UT055E
55
Pound
Not Applicable
ST055L
ST055N
UU055E
CA075L
CA075N
CT075L
CT075N
CU075L
CU075N
DR80G2-BA075N
DR80G2-BA075L
DR80G2-BT075D
DR80G2-BT075L
DR80G2-BT075N
DR80G2-BU075N
DR80G2-BU075L
HA075L
HA075N
HT075D
HT075L
HT075N
HU075L
HU075N
IPD75G2-IT075L
IPD75G2-IT075N
SA075L
SA075N
ST075D
ST075N CT075S
STF75L CT075T
STF75N CU075S
SU075L CU075T
SU075N DR80S2-BT075T SU075T
UA075L DR80S2-BT075S UT075S
UA075N DR80S2-BU075T UT075T
UT075L DR80S2-BU075S UU075S
IPD75S2-IT075S CT075E
ST075S
ST075T
SU075S
CU075E
DR80E2-BT075E
DR80E2-BU075E
HT075E
HU075E
IPD75E2-IT075E
ST075E
75
Pound
UT075N HT075S
UU075T
SU075E
UTF75L HT075T
UTF75N HU075S
UU075L HU075T
UU075N IPD75S2-IT075T
UT075E
UU075E
ST075L
Models continued on next page.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Electric
(Continued)
Gas
DR120G2-BU120N ST120L CT120S
Steam/Thermal Oil
CA120L
CA120N
CT120L
CT120N
CU120L
CU120N
HU120T
HA120L
HA120N
HT120L
HT120N
HU120L
ST120N CT120T
SU120L CU120S
SU120N CU120T
UA120L DR120S2-BT120T ST120T
UA120N DR120S2-BU120S SU120S
UT120L DR120S2-BU120T SU120T
IPD120S2-IT120S
IPD120S2-IT120T
ST120S
120
Pound
Not Applicable
DR120G2-BA120L HU120N
DR120G2-BA120N IPD120G2-IT120N UT120N DR120S2-BT120S UT120S
DR120G2-BT120L IPD120G2-IT120L
DR120G2-BT120N SA120L
DR120G2-BU120L SA120N
UU120L HT120S
UU120N HT120T
HU120S
UT120T
UU120S
UU120T
CA170L
CA170N
CT170L
CT170N
CU170L
CU170N
DR170G2-BU170N ST170L CT170S
HU170T
HA170L
HA170N
HT170L
HT170N
HU170L
ST170N CT170T
SU170L CU170S
SU170N CU170T
UA170L DR170S2-BT170T ST170T
UA170N DR170S2-BU170S SU170S
UT170L DR170S2-BU170T SU170T
IPD170S2-IT170T
IPD170S2-IT170S
ST170S
170
Pound
Not Applicable
DR170G2-BA170L HU170N
DR170G2-BA170N IPD170G2-IT170N UT170N DR170S2-BT170S UT170S
DR170G2-BT170L IPD170G2-IT170L
DR170G2-BT170N SA170L
DR170G2-BU170L SA170N
UU170L HT170S
UU170N HT170T
HU170S
UT170T
UU170S
UU170T
Includes models with the following control suffixes:
EO – OPL electronic
RE – reversing OPL electronic
Nameplate Location
The nameplate is located on the back of the machine
and is programmed in the Control.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Preliminary Information
Audit Information
About the Control
The control collects and stores audit information,
which can be accessed with a PDA or PC. Refer to the
following list for some of the available audit
information. Refer to PC and PDA Application User
Instructions.
This control is an advanced, programmable computer
that lets the owner control most machine features by
pressing a sequence of keypads.
The control allows the owner to program custom
cycles, run diagnostic cycles, and retrieve audit and
error information.
Total Number of Individual Cycle Counters
End of Cycle to Loading Door Open Time
End of Cycle to Start of Next Cycle Time
Total Number of Machine Cycles
Tumblers shipped from the factory have default cycles
and other settings built in. The owner can change the
default cycle or any cycle.
IMPORTANT: It is extremely important that the
tumbler has a positive ground and that all
mechanical and electrical connections are made
before applying power to or operating the tumbler.
Total Number of Operating Minutes
Power Failure Audit Data
The PDA or PC can receive audit and program data
from the control, and send programming data and
diagnostic commands to the control. Refer to PC and
PDA Application User Instructions for additional
information.
Power Failure Recovery
If a cycle is in progress when the power fails, and if
the power outage lasts three or more seconds, the cycle
is lost and cannot be resumed when power recovers. If
the power outage lasts less than three seconds, the
control will resume the cycle when the power
recovers.
Some of the above listed audit data is available
manually. Refer to Collecting Audit Information
section.
Communications
The control has the ability to communicate with a
PDA and a laptop with an IrDA device running the
control software. Devices such as PDAs and laptops
that are IrDA capable (able to transmit information to
machine) that have been tested and approved for use
with the software can be used as a tool for managing
the machine.
70444901
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Preliminary Information
Restore to Factory Defaults
Entering Program Mode
When the user resets to factory default, the control
resets all of the default values. The control also resets
Machine Cycles #1 through #30. The control will also
reset the following to factory-defaults:
1. Press and hold Stop ( ), then Back ( ), then
Up ( ) to enter the programming options.
Default Global Settings
Ignition Retries = 3
Temperature Units = Fahrenheit (°F)
High (H) Temperature = 190 (°F)
Medium (M) Temperature = 160 (°F)
Low (L) Temperature = 140 (°F)
Very Low (VL) Temperature = 120 (°F)
Cool Down Temperature = 100 (°F)
Cool Down Time = 2 minutes
Rapid Advance = Disabled
Multi-Segment Cycles = Disabled
Daylight Saving = Enabled
Key Pad Audio = Enabled
End of Cycle Audio = Enabled (5 seconds)
End of Cycle External Signal = Enabled (5 seconds)
Clean Lint Screen Reminder = Off
Display Limit Errors = Disabled
Manual Diagnostics = Enabled
*Manual Programming = Enabled
**Reverse Cylinder Rotate Time = 120 (seconds)
**Reverse Cylinder Stop Time = 6 (seconds)
**Advanced Reversing = Disabled
***Advanced Options for Moisture Dry = Disabled
***Display Moisture Sensor Error = Disabled
*If manual programming is disabled, programming
changes to the control can only be made with an
external communication device. Refer to PC and PDA
Application User Instructions.
**Only available on units equipped with reversing
feature.
***Only available on units equipped with moisture
sensing feature.
Refer to Factory Defaults, Menu section for
information on Restoring Factory Defaults.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
7
Control Identification
U Models
Operational Keypad
The control includes five keypads. These functions are
available to the operator and are intended to control
and manage operation of the tumbler. Refer to
PROGRAM REVERSING ENERGY HEATING
SAVER
S Models
STOP
START
BACK
PROGRAM REVERSING ENERGY HEATING
SAVER
TMB1371R
Figure 3
STOP
B, C, and I Models
START
BACK
TMB1345R
Figure 1
ECO
H Models
PROGRAM REVERSING ENERGY HEATING
SAVER
TMB1375R
Figure 4
NOTE: The reversing feature is not available on all
models.
STOP
START
BACK
TMB1346R
Figure 2
70444901
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Control Identification
Keypad
UP ARROW
Description
Press to scroll through menu options and edit parameter values.
Press to scroll through menu options and edit parameter values.
DOWN ARROW
BACK ARROW
STOP
Press to go to the list of parameters without saving the value when adjusting the value of a
programming parameter. Also, press to go to the previous menu when the control displays a
parameter, return to Idle Mode when the control displays the main menu or clear an error
message from the display.
Press to pause a cycle while in Run Mode or abort a cycle if the control is in Pause Mode.
Press to start the selected cycle, select an option when in the menu or save a value when
editing a parameter.
START
Status Indicator LED
Description
LED will light up if the control is in Manual Programming Mode or if a cycle is being
modified.
PROGRAM
LED will light up when cylinder is reversing.
LED will light up when a Moisture Dry or Auto Dry cycle is running.
LED will light up when the machine is in the heat portion of the cycle.
Table 1
REVERSING
ENERGY SAVER
HEATING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Identification
Rapid Advance Mode
Operation Modes
If the Rapid Advance Option is enabled, the user can
advance a running machine cycle by pressing the
General Modes of Operation
In each mode of operation, the user may press keypads
or communicate with the control to change the
displayed menu.
Start (
Start (
) keypad. In a Time Dry cycle, pressing the
) keypad will decrease the remaining time
by one minute. Pressing and holding the Start (
keypad will decrease the remaining time by four
minutes per second until the end of the cycle.
)
Power-up Mode
The control enters this mode at power-up. When
power is applied to the tumbler, the control becomes
active and will display its software version as “XX”
(“XX” is the version number) for one second. If the
control was not powered down during a running cycle,
it will enter the Idle Mode. After the control completes
operation in the Power-up Mode it will enter Idle
Mode.
In the Auto-Dry and Moisture Dry cycles, pressing the
Start ( ) keypad will advance the cycle to the next
enabled segment. Note that Auto-Dry cycles only have
one programmable segment.
In the Cool Down segment, pressing the Start (
keypad will decrease the remaining time by one
minute.
)
Idle Mode
When the cycle is completed, the audit counter, Total
Rapid Advance Cycles, is incremented rather than the
Total Machine Cycles audit counter. If the Rapid
Advance Option is disabled preventing a manual
Rapid Advance, the user may still execute a Rapid
Advance using the PDA or PC. Refer to PC and PDA
Application User Instructions for additional
information on using a PDA or PC to Rapid Advance a
cycle.
The control is ready for operation in Idle Mode.
Control can display different menus depending on user
input (keypad press, opening or closing the loading
door, or PDA communication). If there is no user input
for 10 minutes, display will turn off.
While in Idle Mode the control will display the active
cycles. Anytime the control returns to Idle Mode after
a cycle has been run, the control will display the last
run cycle (except the first time the control is powered
up it will show the first cycle).
Pause Mode
If Stop ( ) keypad is pressed or the loading or lint
door is opened while in Run Mode, control enters
Pause Mode.
Press the up arrow ( ) to increment the cycle number.
Press the down arrow ( ) to decrease the cycle
number. If the Start (
) keypad is pressed and
If the door was opened to enter Pause Mode, the
control will show “” until the door is closed or
Pause Mode is exited. If the door is closed, the control
will show “” for one second followed by
“” for one second as well as flash the
either the loading door or lint door is open the control
will show “” for five seconds or until door is
closed.
If the control is in Idle Mode, Cycle Menu is
displayed, loading and lint door closed, and the
Start (
off.
) keypad LED one second on/one second
Start (
Mode.
) keypad is pressed, control will enter Run
If the Stop ( ) keypad was pressed to enter Pause
Mode and the loading door is closed, the control will
show “” until Pause Mode is exited.
Run Mode
The Control enters Run Mode during a cycle. Display
shows machine cycle time remaining, the current cycle
type, segment and temperature. Loading and lint doors
are closed during Run Mode. Press Stop ( ) keypad
to stop cycle and enter Pause Mode. Control enters
Pause Mode if loading or lint door opens. Press
Any time “” is shown on the control, the
Start (
) keypad LED will flash one second on/one
second off to prompt the user to restart the cycle.
Error Mode
This mode will be entered to display all fatal machine
errors.
Start (
) to Rapid Advance.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
10
Control Identification
Communication Mode
Extended Tumble Mode
This mode is entered whenever the control is
communicating with a PDA. Refer to PC and PDA
Application User Instructions.
The Extended Tumble Mode has two portions. The
Anti-Wrinkle Tumble is entered two minutes after the
cycle has ended if the door is not opened. The cylinder
will tumble for 30 seconds every two minutes for up to
one hour.
Cool Down Mode
The control enters the Cool Down Mode after the heat
segment of the cycle is completed. The control turns
the heater off and for steam heated units turns the
damper motor on. The cool down segment will end
once the cool down temperature has been reached or
the programmed cool down time expires, which ever
happens first.
If the door hasn’t been opened and no keys have been
pressed one hour after the Anti-Wrinkle Tumble has
ended, the control increments the Anti-Wrinkle Time
Exceeded audit counter and enters the Delayed
Tumble. The cylinder will tumble for two minutes
every 60 minutes for up to 18 hours.
Reversing Mode (reversing models only)
End of Cycle Mode
Models equipped with the reversing feature will rotate
in the forward direction, pause, rotate in the reverse
direction and then pause for programmable times and
segments of the cycle. Factory default rotate time is
120 seconds and reversing stop time is 6 seconds for
all cycles with reversing enabled.
The control enters End of Cycle Mode after the cool
down segment is finished. The display will toggle
between “” and “” for one second each
until End of Cycle Mode is exited. If the door has not
been opened or a keypad has not been pressed after
two minutes, the machine will enter Extended Tumble
Mode. This mode is exited when the door is opened or
Stop ( ) keypad is pressed. The control will then
return to Idle Mode.
Entering Diagnostic Mode From Idle Mode
When entered from the Idle Mode, the control will be
running a test selected by the user via keypad presses
or communication with a device.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
11
Machine Cycle Definition and Operation
There are 30 machine cycles that can be selected and
run. Machine cycles can be modified or made
“unavailable” by manually editing them in Modify
Rotation Sensor Equipped
Machines
Cycle Menu or by using the PDA to download a
modified machine cycle into the control. Machine
cycles cannot be deleted, but can be made
“unavailable” so that they are not visible from the
Cycle Menu. New machine cycles cannot be created,
but existing machine cycles that have been edited to be
“unavailable” may be re-edited to be available again.
On machines equipped with a rotation sensor, the
control monitors the rotation sensor to verify the
cylinder is rotating. The control calculates the
cylinder’s RPM. If the RPM drops to zero while the
cylinder is supposed to be rotating, the control will
advance to the Cool Down segment of the cycle and an
error message will be displayed.
Machine Cycle Operation
To Start a Cycle
When a cycle is run, the control runs the cycle
segment by segment in a sequence. First the control
examines the Cycle Type chosen to determine if it is a
Time Dry, Auto-Dry or Moisture Dry (if equipped)
cycle type. Then the first segment is examined to see if
it is programmed to “” or “”. If the segment is
programmed to “”, control skips to the next
segment.
1. Press the Up ( ) or Down ( ) keypad to change
cycles.
2. Press Start (
) to start selected cycle.
NOTE: If door is not closed when the Start (
)
keypad is pressed, display will show “”.
At the start of some machine cycles, the control
displays a Total Remaining Cycle time. This time is
taken from the machine cycles as they are
programmed. The Total Remaining Cycle Time begins
to count down as soon as the cycle is started.
Time Dry Cycle
In this type of cycle, the control will regulate the
temperature and time duration as programmed for the
cycle chosen.
Auto-Dry Cycle
If this type of cycle is selected, the control determines
the cycle time based on the temperature and dryness
level programmed for the cycle chosen.
Moisture Dry Cycle (if equipped)
In this type of cycle, the control checks the
programmed material type, programmed target
moisture content, programmed temperature and the
data received from the moisture sensing system to
achieve the desired results.
70444901
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Entering the Manual Mode
For programming, testing, and retrieving information
from the control, it is often necessary to enter the
Manual Mode by following the steps below.
Manual Programming can only be turned on or off
with an external device. Refer to the appropriate
instruction manual. Diagnostics can be turned on and
off using an external device by manual programming.
For an overview of entering the Manual Mode, refer to
the flowchart on the following page.
By default, Manual Programming is turned “”.
The manual features available in each group are as
follows (the menu displayed on the display in this
mode is in parentheses).
How to Enter the Manual Mode
1. Control must be in Idle Mode.
Manual Programming ()
Manual Read Audit ()
Manual Reset ()
2. Press and hold the Stop ( ) keypad, then press
and hold the Back ( ) keypad, then press the
Up ( ) keypad.
3. The display will show “”.
Diagnostic Tests ()
4. Press the Up ( ) or the Down ( ) keypad to
scroll through the options until the desired option
appears in the display.
If a manual parameter is turned off or unavailable
(ex: trying to enter diagnostics while a cycle is
running), the display will change from the selected
feature to “”, an audio signal will sound for one
second and the features in the parameter cannot be
entered. The display will then return to the selected
feature.
5. Press the Start (
displayed mode.
) keypad to enter the
6. To exit, press the Back ( ) keypad. The control
will revert back to Idle Mode.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
13
Entering the Manual Mode
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
the Back (ꢀ) keypad.
Manual Mode: Enter by pressing
Stop ( ), then Back (ꢀ), then
Up (ꢁ) keypads
Press the Up (ꢁ) or
the Down (ꢂ) keypad
to scroll through the
Manual Mode options.
Press the Start ( /ꢀ ) keypad to
enter Manual Programming.
Refer to Manual
“Prog”
Manual
Programming
Programming flowchart.
“Avdit”
Manual Read
Audit
Press the Start ( /ꢀ )
keypad to read audit.
“CyCLE”
Total machine cycles
Press the Start ( /ꢀ )
keypad to read audit.
“totHrS”
Total Run Hours
Press the
Start ( /ꢀ ) keypad.
Press the
Up (ꢁ)
or the
Press the Start ( /ꢀ )
keypad to read audit.
“HEAtHr”
Total Heat Hours
Down (ꢂ)
keypad to
scroll through
the Audit
options.
“rA CyC”
Total Rapid
Advance Cycles
Press the Start ( /ꢀ )
keypad to read audit.
Press the Start ( /ꢀ )
keypad to read audit.
“Ab CyC”
Total Aborted Cycles
“AntiCt”
Total Time
Anti-wrinkle Exceeded
Press the Start ( /ꢀ )
keypad to read audit.
“End2OP”
Average Time From End
of Cycle to Door Open
Press the Start ( /ꢀ )
keypad to read audit.
“End2St”
Average Time From End
of Cycle to Run Mode
Press the Start ( /ꢀ )
keypad to read audit.
“rESEt”
Manual Reset
Press the Start ( /ꢀ )
keypad to reset control.
“diAg”
Diagnostic
Tests
Press the Start ( /ꢀ ) keypad to
enter Diagnostic Tests. Refer to
Diagnostic Tests flowchart.
TMB1372R
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
What Can Be Programmed?
How to Program a Cycle
This feature allows the owner to program cycle
parameters and other features by using the keypads.
The control must have the Manual Programming Mode
enabled, which is the factory default. This mode can
only be turned OFF and ON by using an external
device. Refer to this section when programming the
control.
1. Press the Up ( ) or Down ( ) keypad to scroll
through the option list.
2. Press Start (
) to select an option to program.
3. Press the Up ( ) or Down ( ) keypad to change
the value of that option.
4. Press Start (
) to save the change.
For an overview of the programming organization,
refer to the flowcharts on the following pages.
NOTE: Press the Back ( ) keypad to leave the
option without saving any change.
For more advanced users, a quick reference list of the
options available through the programming mode is
located on this page.
5. After pressing Start (
next option in the list.
), control will go to the
6. Press Back ( ) keypad to go to Idle Mode.
NOTE: The codes in the Option Display column of
the Programmable Options List are what will show
in the display when that option is selected.
Programmable Options Available
Option
Number Display
Option
Default
Description
Cycle Programming
Cycle XX (XX represents cycles 1-30) -
Value Range
Value
1
“”
“”
-
-
a
-
1 “”
2 “”
Cycle XX Enable Disable
Cycle XX Type
-
-
on/oFF
tinE (Time Dry), Auto (Auto Dry), noist
(Moisture Dry)
3 “”
Cycle XX Material Type
-
0 (Cotton), 1 (Blend), 2 (Bedding), 3
(Delicate), 4 (Synthetic), 5 (Wool)
4 “”
5 “”
Cycle XX Time Past Target (minutes)
Segment 1
-
-
0-15
CXXS11 (Segment 1 Enable/Disable),
CXXS12 (Segment 1 Time),
CXXS13 (Segment 1 Temperature),
CXXS14 (Segment 1 Auto Dry Target
Level),
CXXS15 (Segment 1 Moisture Dry Target
Moisture),
CXXS16 (Segment 1 Reversing Enable/
Disable)
6 “”
Segment 2
-
CXXS21 (Segment 2 Enable/Disable),
CXXS22 (Segment 2 Time),
CXXS23 (Segment 2 Temperature),
CXXS24 (Segment 2 Auto Dry Target
Level),
CXXS25 (Segment 2 Moisture Dry Target
Moisture),
CXXS26 (Segment 2 Reversing Enable/
Disable)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
Option
Number Display
Option
Default
Value
Description
Value Range
7 “”
Segment 3
Segment 4
Segment 5
-
-
-
-
CXXS31 (Segment 3 Enable/Disable),
CXXS32 (Segment 3 Time),
CXXS33 (Segment 3 Temperature),
CXXS34 (Segment 3 Auto Dry Target
Level),
CXXS35 (Segment 3 Moisture Dry Target
Moisture),
CXXS36 (Segment 3 Reversing Enable/
Disable)
8 “”
CXXS41 (Segment 4 Enable/Disable),
CXXS42 (Segment 4 Time),
CXXS43 (Segment 4 Temperature),
CXXS44 (Segment 4 Auto Dry Target
Level),
CXXS45 (Segment 4 Moisture Dry Target
Moisture),
CXXS46 (Segment 4 Reversing Enable/
Disable)
9 “”
CXXS51 (Segment 5 Enable/Disable),
CXXS52 (Segment 5 Time),
CXXS53 (Segment 5 Temperature),
CXXS54 (Segment 5 Auto Dry Target
Level),
CXXS55 (Segment 5 Moisture Dry Target
Moisture),
CXXS56 (Segment 5 Reversing Enable/
Disable)
10 “”
11 “”
Cool Down
Reversing
CXXCd1 (Cool Down Temperature),
CXXCd2 (Cool Down Time),
CXXCd3 (Cool Down Segment Reversing
Enable/Disable)
-
CXX r1 (Cycle Reversing Enable/Disable),
CXX r2 (Cycle Reversing Rotate Time),
CXX r3 (Cycle Reversing Stop Time)
2
3
“”
Global Cool Down
-
-
a
“ ”
Cool Down Temperature
Cool Down Time (minutes)
Global Reversing Parameters
Rotate Time (seconds)
Stop Time (seconds)
100°F/38°C 70°-110°F/21°-43°C
b
“ ”
2
1-15
“”
“ ”
“ ”
“ ”
“”
“ ”
“ ”
-
-
a
b
c
7 (120)
3-9 (30-540 seconds)
0-4 (6-10 seconds)
0 (oFF), 1 (on)
-
0 (6)
Advanced Reversing
0
4
Global Temperatures
Global Very Low Temperature
Global Low Temperature
-
a
120°F/49°C 100°-120°F/38°-49°C
b
140°F/60°C 120°-140°F/49°-60°C (50, 75, 120, 170
Pound Models), 105°-145°F/41°-63°C (25,
30, T30 Pound Models), 125°-155°F/52°-
68°C (35, T45, 55 Pound Models)
c
“ ”
Global Medium Temperature
160°F/71°C 140°-160°F/60°-71°C (50, 75, 120, 170
Pound Models), 135°-160°F/57°-71°C (25,
30, T30 Pound Models), 145°-165°F/63°-
74°C (35, T45, 55 Pound Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
Option
Number Display
Option
Default
Value
Description
Value Range
d
“ ”
Global High Temperature
190°F/88°C 160°-190°F/71°-88°C (35, T45, 55, 50, 75,
120, 170 Pound Models), 155°-190°F/68°-
88°C (25, 30, T30 Pound Models)
5
6
“” Global Audio Signal
-
-
a
b
c
“ ”
“ ”
“ ”
“”
“ ”
“ ”
End of Cycle
1
5
1
-
0 (oFF), 1 (on)
1-120
End of Cycle Duration (seconds)
Keypad Feedback
0 (oFF), 1 (on)
-
External Signal
a
External Signal End of Cycle
1
0 (oFF), 1 (on)
1-120
b
External Signal End Of Cycle Duration 5
(seconds)
7
8
9
“” Multi-Segment Cycles
“” Advanced Moisture Dry Options
“” Error Displays
0
0
-
1 (Enable), 0 (Disable)
1 (Enable), 0 (Disable)
-
a
“”
“ ”
“ ”
Display Limit Errors
Display Moisture Sensor Error
Temperature
Auto Ignite Retry
Clean Lint Reminder
Real Time Clock
Minutes
0
1
0
3
0
-
1 (Enable), 0 (Disable)
b
1 (Enable), 0 (Disable)
10
11
12
13
0 (Fahrenheit), 1 (Celsius)
“”
0-255
“”
“”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
“ ”
0 (off)-255
-
a
b
c
d
e
f
-
0-59
Hours
-
0-23
Day
-
1-7
Date
-
1-31
Month
-
1-12
Year
-
0-99
g
Daylight Saving
1
0
1
1 (Enable), 0 (Disable)
1 (Enable), 0 (Disable)
1 (Enable), 0 (Disable)
14
15
“” Manual Rapid Advance
“” Manual Diagnostics
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
“Prog”
Manual Programming
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
the Back (ꢀ) keypad.
Press the
Start ( /ꢀ ) keypad
“CyCLE-”
Cycle Programming
“CyCXX”
Cycle to be programmed
“CXXEn”
Cycle XX Enable Disable
“on”
Enable
“oFF”
Disable
“CXXtyP”
Cycle XX Type
“tinE”
Time Dry
Press the Up (ꢁ)
“Avto”
or the Down (ꢂ)
keypad to scroll
through the
Auto Dry
programmable options.
“noist”
Moisture Dry
“CXXnt”
Cycle XX Material Type
“0”
Cotton
“CXXtPt”
Cycle XX
Time Past Target
“1”
Blend
“2”
Bedding
“3”
Delicate
“4”
Synthetic
continued
“5”
Wool
continued
TMB1373R-a
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
continued
continued
the Back (ꢀ) keypad.
“CXXS1-”
Segment 1
“CXXS11”
Segment 1
Enable/Disable
“CXXS12”
Segment 1
Time
“CXXS2-”
Segment 2
“CXXS21”
Segment 2
“CXXS13”
Segment 1
Temperature
Enable/Disable
“CXXS22”
Segment 2
Time
“CXXS3-”
Segment 3
“CXXS14”
Segment 1 Auto Dry
Target Level
“CXXS31”
Segment 3
Press the Up (ꢁ)
“CXXS23”
Segment 2
Temperature
or the Down (ꢂ)
keypad to scroll
through the
Enable/Disable
“CXXS15”
Segment 1 Moisture
Dry Target Level
programmable options.
“CXXS32”
Segment 3
Time
“CXXS24”
Segment 2 Auto Dry
Target Level
“CXXS16”
Segment 1 Reversing
Enable/Disable
“CXXS33”
Segment 3
Temperature
“CXXS25”
Segment 2 Moisture
Dry Target Level
“CXXS34”
Segment 3 Auto Dry
Target Level
“CXXS26”
Segment 2 Reversing
Enable/Disable
“CXXS35”
Segment 3 Moisture
Dry Target Level
“CXXS36”
Segment 3 Reversing
Enable/Disable
continued
continued
TMB1373R-b
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
continued
continued
the Back (ꢀ) keypad.
“CXXS4-”
Segment 4
“CXXS41”
Segment 4
Enable/Disable
“CXXS42”
Segment 4
Time
“CXXS5-”
Segment 5
“CXXS51”
Segment 5
“CXXS43”
Segment 4
Temperature
Enable/Disable
“CXXS52”
Segment 5
Time
“CXXS44”
Segment 4 Auto Dry
Target Level
Press the Up (ꢁ)
“CXXS53”
Segment 5
Temperature
or the Down (ꢂ)
keypad to scroll
through the
“CXXS45”
Segment 4 Moisture
Dry Target Level
programmable options.
“CXXS54”
Segment 5 Auto Dry
Target Level
“CXXS46”
Segment 4 Reversing
Enable/Disable
“CXXS55”
Segment 5 Moisture
Dry Target Level
“CXXS56”
Segment 5 Reversing
Enable/Disable
continued
continued
TMB1373R-c
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
the Back (ꢀ) keypad.
continued
continued
“CXXCd-”
Cool Down
“CXXCd1”
Cool Down
Temperature
Press the Up (ꢁ)
or the Down (ꢂ)
keypad to scroll
through the
“CXXCd2”
Cool Down Time
programmable options.
“CXXCd3”
Cool Down
Segment Reversing
Enable/Disable
“CXXr-”
Reversing
“CXX r1”
Cycle Reversing
Enable/Disable
“Cd-”
Global Cool Down
“CXX r2”
Cycle Reversing
Rotate Time
“Cd 1”
Cool Down
Temperature
“CXX r3”
Cycle Reversing
Stop Time
“Cd 2”
Cool Down
Time
continued
TMB1373R-d
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
continued
the Back (ꢀ) keypad.
“rEv-”
Global Reversing
Parameters
“rEv 1”
Rotate Time
“rEv 2”
Stop Time
Press the Up (ꢁ)
or the Down (ꢂ)
keypad to scroll
through the
“rEv 3”
Advanced Reversing
(On/off)
programmable options.
“tEnp-”
Global Temperatures
“tEnp 1”
Global Very
Low Temperature
“tEnp 2”
Global Low
Temperature
“tEnp 3”
Global Medium
Temperature
“tEnp 4”
Global High
Temperature
continued
TMB1373R-e
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
continued
the BACK (ꢀ) keypad.
“Avdio-”
Global Audio Signal
“Avd 1”
End of Cycle
(On/off)
“Avd 2”
End of Cycle
Duration
Press the Up (ꢁ)
or the Down (ꢂ)
keypad to scroll
through the
“Avd 3”
Keypad Feedback
(On/off)
programmable options.
“ESig 1”
“ESig-”
External Signal
External Signal
End of Cycle (on/off)
“ESig 2”
“nvLSEg”
Multi-Segment Cycles
(on/off)
External Signal
End of Cycle Duration
“ndryOP”
Advanced Moisture
Dry Options
(Enable/Disable)
“LiNitS”
Display Limit Errors
(Enable/Disable)
“Error-”
Error Displays
“noist”
continued
Display Moisture
Sensor Error
(Enable/Disable)
TMB1373R-f
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Control
To enter a programming
option, press the Start ( /ꢀ )
keypad. To exit, press
the BACK (ꢀ) keypad.
continued
“t FC”
Temperature
“AIg”
Auto Ignite Retry
Press the Up (ꢁ)
“Lint”
Clean Lint Reminder
or the Down (ꢂ)
keypad to scroll
through the
programmable options.
“rtC 1”
Minutes
“rtC-”
Real Time Clock
“rtC 2”
Hours
“rtC 3”
Day
“rtC 4”
Date
“rtC 5”
“rAPdEn”
Manual Rapid Advance
(on/off)
Month
“rtC 6”
Year
“diAgEn”
Manual Diagnostics
(on/off)
“rtC 7”
Daylight Savings
(on/off)
TMB1373R-g
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Collecting Audit Information
This feature allows the owner to retrieve audit
2. Once the desired option appears in the display,
information stored in the tumbler by pressing a
sequence of pads on the control. For an explanation of
the audit options available, refer to the Audit Options
List on this page.
press the Start (
audit count.
) keypad once to start the
3. Press the Start (
) keypad again. The control
will go to the next audit option in the Audit
Options List.
How to Enter Audit Feature
4. To select other audit options, repeat steps 1 – 3.
1. Control must be in Manual Mode to start. Refer
to Entering the Manual Mode.
How to Exit Audit Feature
2. Press the Up ( ) or the Down ( ) keypad until
Press the Back ( ) keypad until the control returns to
Idle Mode.
“” appears.
3. Press the Start (
appear.
) keypad. “” will
If the procedure did not work, the control will return to
the Idle Mode.
How to Read Audit Data
1. Use the Up ( ) or the Down ( ) keypad to scroll
through various options until the desired option is
shown in the display. Refer to the Audit Options
options available.
Audit Options List
Display
Description
Total # of Machine Cycles
Total # of Run Hours
Total # of Heat Hours
Total # of Rapid Advance Cycles
Total # of Aborted Cycles
Total # of Times Anti-Wrinkle Exceeded
Average Time from End of Cycle to Door
Open (Last 25 Cycles)
Average Time from End of Cycle to Run
Mode (Last 25 Cycles)
Table 2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
25
Manual Reset
This feature allows the owner to reset the tumbler
control’s programming data to the factory default
settings by pressing a sequence of pads on the control.
For an explanation of the Factory Default Settings,
refer to Default Tumbler Settings.
How to Enter Manual Reset
1. Control must be in Manual Mode to start.
Refer to Entering the Manual Mode.
2. Press the Up ( ) or the Down ( ) keypad until
“” appears.
3. Press the Start (
) keypad. The control will
be blank until the programming is complete.
Once the program has been reset, the control will
revert back to the Manual Mode, displaying
“”.
70444901
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
26
Testing Machine and
Electronic Control Functions
This feature allows the owner to run diagnostic tests
3. Press the Start (
) keypad. Display will
on various tumbler operations without servicing the
tumbler. The tests that are available are shown in
change to “” indicating the control
software version number test.
4. Press the Up ( ) or the Down ( ) keypad to
scroll through the diagnostic test options.
For an overview of the manual diagnostic test feature,
refer to the flowchart on the following page.
How to Start Tests
To start a diagnostic test, refer to the quick reference
How to Enter Testing Feature
) keypad
1. Enter Manual Mode. Refer to Entering the
Manual Mode.
when the desired test is displayed. For detailed
information on each test, read the appropriate description.
2. Press the Up ( ) or the Down ( ) keypad until
How to Exit Testing Feature
“” appears.
Press the Back ( ) keypad. The display will return to
Idle Mode.
Diagnostic (Testing) Mode - Quick Reference Chart
Display
“”
Diagnostic Mode
Control Software Version
Loading Door Status
Lint Door Status
“”
“”
“”
Heater Interlock Test
“”
Fan Motor Contactor Status ( represents input status, open “” or closed “”
“”
“ ”
“ ”
“ ”
Fan Motor Centrifugal Switch Status ( represents input status, open “” or closed “”
Cabinet High Limit Thermostat Status ( represents input status, open “” or closed “”
Stove High Limit Thermostat 1 Status ( represents input status, open “” or closed “”
Stove High Limit Thermostat 2 Status ( represents input status, open “” or closed “”
DIP Switch Status
“”
“”
“”
“”
“”
“”
“”
“”
“”
ICM Alarm Status
ICM Reset Test
External Alarm Test
Dryer On Temperature Test
Thermistor Temperature Test
Machine Config #2 Display
Machine Config #3 Display
Airflow Switch Test
“”
Fan Motor Test
“”
“”
“”
“ ”
“ ”
Damper Motor Test*
Reverse Motor Test*
Rotation Sensor Test*
Moisture Sensor Test (Shorted test jumper)*
Moisture Sensor Test (Resistance test jumper)*
* = Tests only shown if enabled by the DIP switch configuration.
Table 3
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
27
Testing Machine and Electronic Control Functions
“diAg”
Diagnostic Tests
“dSoft”
To enter a diagnostic test,
press the Start ( /ꢀ ) keypad.
To exit, press the Back (ꢀ) keypad.
Control Software Version Number Test
Press the Start
(
/ꢀ ) keypad.
“ddoor”
Press the Up (ꢁ) or
the Down (ꢂ) keypad
to scroll through the
Diagnostic Test options.
Loading Door Status
“dLint”
Lint Door Status
“dHEAt”
Heater Interlock Test
“ddiP”
DIP Switch Status
“FCOnXX”
Fan Motor Contactor Status
“diCnAL”
ICM Alarm Status
“FnCSXX”
Fan Motor Centrifugal Switch
“diCnrS”
ICM Reset Test
“Cab XX”
Cabinet High Limit Thermostat Status
“dEALrn”
External Alarm Test
“SL XX”
Stove High Limit Thermostat 1 Status
“ddryon”
Dryer On Temperature Test
“SL2 XX”
Stove High Limit Thermostat 2 Status
“dtHEr”
Thermistor Temperature Test
“dConF2”
Machine Config #2 Display
“dConF3”
Machine Config #3 Display
“dAFS”
Airflow Switch Test
“dFAn”
Fan Motor Test
“ddAnPr”
Damper Motor Test
“drEvSE”
Reverse Motor Test
“drotAt”
Rotation Sensor Test
“drnC 1”
Moisture Sensor Test (Shorted)
“drnC 2”
Moisture Sensor Test (Resistance)
R
TMB1374R
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing Machine and Electronic Control Functions
Heater Interlock Test
Diagnostic Test Descriptions
While this test is running, the control will show the
status of the following inputs for two seconds each.
The control will continue scrolling through the input
status displays until the test is aborted.
Control Software Version Number Test
This option displays the control software version
number. To start test, control must be in the Testing
Mode. Refer to “How to Enter Testing Feature” at the
beginning of this section.
To start test, the control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start (
) keypad. The display
will show “xx” where “xx” is the software version
number.
To enter, press Start (
). Refer to five sections
below for more details on individual statuses.
To exit the Software Version Number Test, press the
Back ( ) keypad. The control will return to the testing
mode.
NOTE: These switches are tested in sequence. If
one switch is sensed open, the rest will be open as
well. For example, if the fan motor contactor switch
is open, all of the switches will be open.
Loading Door Test
This option tests the loading door switch. To start test,
control must be in the Testing Mode. Refer to “How to
Enter Testing Feature” at the beginning of this
section.
To exit the test, press the Back ( ) keypad. The
control will return to the testing mode.
Fan Motor Contactor Switch
The display will show “” if the switch is
sensed open and “” if the switch is sensed
closed.
To enter, press the Start (
) keypad. The display
will show “” when the loading door switch is
open and “” when the loading door switch is
closed.
Fan Motor Centrifugal Switch
The loading door switch has to be closed or open for at
least one second for the control to register the switch
as closed or open.
The display will show “” if the switch is
sensed open and “” if the switch is sensed
closed.
To exit the Loading Door Test, press the Back ( )
keypad. The control will return to the testing mode.
Cabinet High Limit Thermostat
The display will show “ ” if sensed open for at
least 1.5 seconds and “ ” if sensed closed for at
least one second.
Lint Door Test
This option tests the lint door switch. To start test,
control must be in the Testing Mode. Refer to “How to
Enter Testing Feature” at the beginning of this
section.
Stove High Limit Thermostat 1
The display will show “ ” if sensed open for at
least 1.5 seconds and “ ” if sensed closed for at
least one second.
To enter, press the Start (
will show “” when the lint door switch is open
and “” when the lint door switch is closed.
) keypad. The display
Stove High Limit Thermostat 2
The lint door switch has to be closed or open for at
least one second for the control to register the switch
as closed or open.
The display will show “ ” if sensed open for at
least 1.5 seconds and “ ” if sensed closed for at
least one second.
NOTE: Loading door must be closed while testing
lint door.
To exit the Lint Door Test, press the Back ( ) keypad.
The control will return to the testing mode.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
29
Testing Machine and Electronic Control Functions
Dip Switch Status
according to the DIP switch configuration. The control
will show which switches are in the ON position.
DS8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
DS7
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
DS6
OFF
OFF
OFF
OFF
OFF
OFF
ON
DS5
OFF
OFF
OFF
OFF
OFF
ON
DS4
OFF
OFF
OFF
OFF
ON
DS3
OFF
OFF
OFF
ON
DS2
OFF
OFF
ON
DS1
OFF
ON
Display
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Table 4
ICM Alarm Status
External Alarm Test
This option shows the status of the ICM (Ignition
Control Module) Alarm.
This option tests whether the external alarm is
working.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start (
) keypad. The display
To enter, press the Start (
will show “” and the external alarm will
sound until the test is exited.
) keypad. The display
will show “ ” if the alarm is active for at least
one second or “” if the alarm is not active for
one second.
To exit this test, press the Back ( ) keypad. The
control will return to the testing mode.
To exit the test, press the Back ( ) keypad. The
control will return to the testing mode.
ICM Reset Test
The ICM Reset Test can be used to both activate the
ICM alarm signal and reset the ICM alarm. When this
test is started, the ICM reset will become active. If the
reset signal is active for a long enough period of time
(4 seconds) the ICM Lockout input will become
active. To reset the ICM, stop the ICM Reset Test and
then start the test again until the ICM Lockout input
becomes inactive (4 seconds) and then stop the ICM
Reset Test. If “” shows on the display, ICM
Reset output is active.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
30
Testing Machine and Electronic Control Functions
Tumbler On Temperature Test
Machine Configuration Display #2 Test
This option tests the temperature inside the cylinder
while running a cycle.
This option shows the machine configuration values
for the machine type.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start (
will show “ ” (Fahrenheit) or “ ”
(Celsius). Use the Up ( ) or the Down ( ) keypad to
) keypad. The display
To enter, press the Start (
) keypad. The display
will show “ XXX”, with “XXX” the number
corresponding to the machine capacity. Refer to
select desired temperature. Press the Start (
)
keypad to begin cycle. While the test is running the
control will display the temperature estimated in the
cylinder (“ ” or “ ”). Once the cylinder
temperature stabilizes at the target temperature, the
heater is turned off and there is a two minute cool
down period. During cool down, the control will
display the time remaining as “ ”.
Value
Description
25, 30 Pound Tumbler
2
4
30, 45 Pound Stack Tumbler
35, 55 Pound Tumbler
5
12
50, 75, F75, 120, 170 Pound Tumbler
NOTE: This test does not increment the Total # of
Cycles audit counter.
Table 5
To exit Machine Configuration Display #2 Test, press
the Back ( ) keypad. The control will return to the
testing mode.
To exit the test, press the Back ( ) keypad. The
control will return to the testing mode.
Thermistor Temperature Test
This option displays the temperature sensed at the
thermistor in 5°F increments.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start (
) keypad. The display
will show “ ” or “ ”. The “” will show
Fahrenheit, the “” will show Celsius and the “”
will show degrees. If control senses a shorted
thermistor, the display will show “ ”. If the
control senses an open thermistor, the display will
show “ ”.
To exit this test, press the Back ( ) keypad. The
control will return to the testing mode.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
31
Testing Machine and Electronic Control Functions
Machine Configuration Display #3 Test
Fan Motor Test
This option shows the fan motor running.
This option shows the machine configuration values
for the machine capacity.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start (
) keypad. The display
will show “
” to indicate the fan motor is going
To enter, press the Start (
will show “ XXX”, with “XXX” representing the
) keypad. The display
to run.
The test must run for at least six seconds before it can
be exited and off for six seconds before the test can be
run again.
To exit Machine Configuration Display #3 Test, press
the Back ( ) keypad. The control will return to the
testing mode.
NOTE: This test does not count towards the total
machine run time operation.
Value
0
Description
To exit Fan Motor Test, press the Back ( ) keypad.
The control will return to the testing mode.
Tumbler
17
18
19
20
21
22
23
24
25
26
27
28
29
30
25 Pound Tumbler
Damper Motor Test
30 Pound Tumbler
This option shows the damper motor running.
30 Pound Stack Tumbler
30 Pound Stack Tumbler – Lower Pocket
30 Pound Stack Tumbler – Upper Pocket
35 Pound Tumbler
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start (
will show “” to indicate the damper motor is
going to run.
) keypad. The display
45 Pound Stack Tumbler
45 Pound Stack Tumbler – Lower Pocket
45 Pound Stack Tumbler – Upper Pocket
50 Pound Tumbler
The test must run for at least six seconds before it can
be exited and off for six seconds before the test can be
run again.
55 Pound Tumbler
NOTE: This test does not count towards the total
machine run time operation.
75, F75 Pound Tumbler
120 Pound Tumbler
To exit Damper Motor Test, press the Back ( )
keypad. The control will return to the testing mode.
170 Pound Tumbler
Reverse Motor Test
Table 6
This option shows the reverse motor running.
Airflow Switch Test
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
This option shows the current state of the airflow
switch.
To start test, control must be in the Testing Mode.
Refer to “How to Enter Testing Feature” at the
beginning of this section.
To enter, press the Start (
) keypad. The display
will show “” to indicate the reverse motor is
going to run.
To enter, press the Start (
) keypad. The display
The test must run for at least six seconds before it can
be exited and off for six seconds before the test can be
run again.
will show “ ” or “ ”, with “ ”
being open and “ ” being closed.
Switch has to be closed for at least one second or open
for at least one second for a valid change.
NOTE: This test does not count towards the total
machine run time operation.
To exit Airflow Switch Test, press the Back ( )
keypad. The control will return to the testing mode.
To exit Reverse Motor Test, press the Back ( )
keypad. The control will return to the testing mode.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
32
Testing Machine and Electronic Control Functions
4. The control will advance through the sequence of
test steps whenever any keypad is pressed, with
the exception of the Keypad Test. Refer to
Production Test Cycle
To Enter Production Test Cycle
1. Be certain control is in Idle Mode.
To Exit Production Test Cycle
2. While pressing and holding the Down ( )
keypad with one hand, press the Back ( )
keypad with the other hand.
The test will be exited when the time reaches “” on
the control in the 10 Minute Test Cycle. Otherwise, the
control must be powered down to end the test.
3. When the control enters the Production Test
Cycle, it will first display “ ” with the “”
showing the software version of the control.
Production Test Cycle Quick Reference Table
Display
Test Mode
Software Version
Control Type
Comments
XX is the software version number.
“
”
“ ”
“
2, 3, 4, 5 or 6, depending on brand.
”
Keypad Test
When a key is pressed, the control will display the number assigned to
the keypad. As each keypad is pressed, the control will display the
number assigned to it in the last digit of the display until the next key is
pressed (example, if Key 1 is pressed the control will show “ ”).
When all keypads have been pressed, the control will advance to next
step after a one second delay.
“” or
“”
Loading Door Test
Lint Door Test
The control will display the status of the loading door: “” if door
is open or “” if door is closed.
“” or
“”
The control will display the status of the lint door: “” if door is
open or “” if door is closed. Loading door must be closed.
All LEDs and
display segments
will light
Show Entire Display Mode The audio signal is turned off. Control will stay in this mode until any
key is pressed.
“
”
Machine Configuration #2 is the configuration byte value. The control will remain in this mode
Display
until any key is pressed.
–
DIP Switch Configuration The control will show the sum of all switches in the position. The
control will remain in this mode until any key is pressed.
Degrees in 5°F
increments,
Thermistor Temperature
Test
The temperature will be displayed in either Fahrenheit or Celsius,
depending on machine’s configuration (refer to Programming Control).
If control senses a shorted thermistor, SH will be displayed. If control
senses an open thermistor, OP will be displayed.
“
“
”,
”
–
Moisture Sensor 1 Test
(Shorted)
Refer to Diagnostic Test Descriptions. Test step lasts for 15 seconds.
–
Moisture Sensor 2 Test
(Resistance)
Refer to Diagnostic Test Descriptions. Test step lasts for 15 seconds.
“ ”
10 Minute Test Cycle
Determines if tumbler can function in a cycle for 10 minutes. Start pad
will flash one second on and one second off. The Start pad can be used to
decrease time remaining. If Start pad is not pressed within 4.25 minutes,
the control will return to Idle Mode.
NOTE: If power to the control is turned off before 10 Minute Test Cycle has ended, the cycle will be cleared
from control.
Table 7
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Machine Errors
The control displays and logs errors as they occur.
Shorted Thermistor Error
When the control senses the error condition, the audit
counter for that error increases by one. The control
saves the time and date of the last eight (8) errors that
have occurred. Following is a list of possible errors:
Any time the control senses a temperature greater than
210 + 4 °F during an active cycle, the control will
enter the Cool Down portion of the cycle, display this
error message, and turn on the audio signal. The
control will continue to display the error message until
any of the keypads are pressed, the Cool Down portion
of the cycle has ended, and the temperature reading is
less than 210 °F. Press any keypad to stop audio signal.
Once all three occur, the control will return to the Idle
Mode. This error will cause the corresponding Shorted
Thermistor Error Audit Counter to be incremented and
is saved in the Last Eight Alarms Menu.
PDA Communications Error
These errors may occur during communications.
When an error occurs, the display indicates the error
message on the control for a few seconds. When a
PDA communication error occurs, the audit counter
Total Bad IR Communications is incremented, the
hour, date, and year of the event are saved, and the
error code is saved. An active machine cycle is not
affected when there is an error during PDA
Stove and Cabinet Limit Errors
communications and this error information is not
stored in the Last Eight Alarms Menu.
There are up to two Stove Limit thermostats and one
Cabinet Limit thermostat on the machine. While the
heat relay is on, if the stove temperature or cabinet
temperature reaches the high temperature for the
particular limit thermostat, the heater will turn off
automatically and the control will continue the cycle
with no heat until the limit thermostat resets. Once the
control reaches the End of Cycle the control will
display the appropriate error message, if programmed
to do so, and sound the audio signal. The control will
continue displaying the error message until the control
returns to Idle mode.
Open Thermistor Error
Any time the control senses a temperature less than 0
°F after the first three minutes of an active cycle, the
control will go to Cool Down, display this error
message, and then turn on the audio signal. The
control will continue to display the error message until
any of the keypads are pressed, the Cool Down portion
of the cycle has ended, and the temperature reading is
greater than 0°F. Press any keypad to stop audio
signal. Once all three occur, the control will return to
the Idle Mode. This error will cause the corresponding
Open Thermistor Audit Counter to be incremented and
is saved in the Last Eight Alarms Menu.
The control will increment the appropriate stove or
cabinet error counter and record the error in the Last
Eight Alarms Menu.
NOTE: On some models the stove and cabinet limit
thermostats need to be manually reset. The
remainder of the cycle will be run with no heat. On
these models, the thermostat(s) must be reset prior
to cycling power or the control will return back to
Error Mode.
70444901
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
34
Machine Errors
Airflow Switch Does Not Close After Cycle
Started
Auto Ignition Retry (Gas Models
Only)
If the airflow switch does not close within 5 seconds
of the start/re-start of a cycle, the control will go to the
Cool Down portion of the cycle, display an error
message and sound the audio alarm. Once the Cool
Down portion of the cycle ends, the control will
continue to display the error message until the power
is cycled to the machine or the Back ( ) keypad is
pressed. When this error occurs, the Airflow Switch 2
error counter will be incremented and the error will
also be saved to the Last Eight Alarms Menu.
If the Ignition Control Module (ICM) fails to ignite the
gas valve the ICM will send an ICM Lockout Alarm to
the control. When the control receives the ICM
Lockout Alarm it will increment the ICM Lockout
Alarm audit counter. When the error becomes fatal
(user input needed to restart the machine) the control
will increment the Heat Error audit counter and record
the Heat Error in the Last Eight Alarms Menu.
If the ICM needs to be manually reset, when the
control receives the ICM Lockout Alarm it will
display the Cycle Stopped Menu with text prompting
Airflow Switch Bounces During A
Running Cycle
the user to press the Start (
) keypad to reset the
ICM. The user can continue to reset the ICM until
there are no more programmable retry attempts
(factory default is 3) or the gas ignites. On machines
equipped with an ICM that does not need to be
manually reset, when the control receives the ICM
Lockout Alarm it will turn the heat relay off for twenty
(20) seconds and then turn it back on to try and ignite
the gas. The control will continue to try and ignite the
gas until there are no more programmable retry
attempts (factory default is 3) or the gas ignites. If the
ICM fails to ignite the gas on the last attempt the
control will start the Cool Down portion of the cycle,
display the heat error message and sound the audio
signal. When the Cool Down portion of the cycle ends
the control will continue to display the error message
until power is cycled to the machine or a user presses
the Back ( ) keypad.
If the airflow switch is open for at least one second,
the heat will be turned off and will remain off until the
switch is observed closed for at least 5 seconds (it is
flagged as an airflow switch bounce). If there are 5
airflow switch bounces within 5 minutes the control
will go to the Cool Down portion of the cycle, display
an error message and sound the audio signal. When the
Cool Down portion of the cycle ends, the control will
continue displaying the error message until power is
cycled or a user presses the Back ( ) keypad. When
this error occurs, the Airflow Switch Bounce Error
will be incremented and the error will also be saved to
the Last Eight Alarms Menu. The Airflow Switch
Bounce counter will be incremented for every instance
of an airflow switch bounce.
Rotation Sensor Error
Air Flow Switch Errors
If the machine is equipped with a rotation sensor, the
control will constantly monitor the input and calculate
the cylinder’s rpm. If the rpm drops to zero while the
cylinder is supposed to be spinning, the control will go
to the Cool Down portion of the cycle. The control
will display an error message and sound the audio
signal. Once the Cool Down portion ends, the control
will continue to display the error message until power
is cycled to the machine. This error will increment the
Rotation Sensor Error counter and will be saved in the
Last Eight Alarms Menu.
The control will flag an Airflow Switch Error under
several conditions. Airflow Switch Errors will be
processed differently depending upon what state the
machine was in when the error was detected.
Airflow Switch Sensed Closed While Not
In Run Mode
If an airflow switch is sensed closed 30 seconds after
entering Idle Mode, Pause Mode or End of Cycle
Mode, the control will display an error message until
power is cycled or the error clears. The cycle will not
start and all user inputs will be ignored. If the error
does clear, the control will go back to its previous
mode of operation. When this error occurs the Airflow
Switch 1 error counter will be incremented and the
error will also be saved to the Last Eight Alarms
Menu.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
35
Machine Errors
Fan Motor Contactor Error
DIP Switch/Harness Index Mismatch
Error
If the control attempts to turn on the heater relay and
the control does not sense that the Fan Motor
On power up the control reads the Temperature Index
Harness value and compares that with the value of
switch 1, switch 2 and switch 3 on the DIP switch
configuration. If the result is an invalid setup the
control will not enter Idle mode and instead enter Error
Mode. The control will ignore all user inputs and
display an error message. The machine must be
powered down and the correct temperature index
harness must be installed and/or the DIP switch
configuration must be corrected.
Contactor is closed, the control will go to the Cool
Down portion of the cycle, display an error message
and turn on the audio signal. Once the Cool Down
portion of the cycle ends, the control will continue
displaying the error message until power is cycled or
the Back ( ) keypad is pressed. This error will
increment the Fan Motor Contactor Error counter and
will be saved in the Last Eight Alarms Menu.
Fan Motor Centrifugal Switch Error
Moisture Sensor Error
If the control attempts to turn on the fan motor and the
fan motor contactor is sensed closed but the Fan Motor
Centrifugal Switch fails to close, the control will go
into the Cool Down portion of the cycle, display an
error message and turn on the audio signal. Once the
Cool Down portion of the cycle ends, the control will
continue displaying the error message until power is
cycled or the Back ( ) keypad is pressed. This error
will increment the Fan Motor Centrifugal Switch error
counter and will be saved in the Last Eight Alarms
Menu.
When in Idle Mode, the control will begin to monitor
the moisture sensor input. If the moisture sensor
circuitry detects a load present signal read consistently
(every second) for a ten minute period without user
input, the control will declare a load sensed. If at any
time during this sensing period, user input is detected
or the control determines that there is no load present,
it resets the load detected counter. After this ten
minute period with a consistent load sensed, the
control queues the “is dryer empty” (display “”,
“”, “” each for two seconds) prompting
the user to answer whether the machine is currently
empty, pressing the Up ( ) or Down ( ) keypads will
toggle between yes and no. If the operator selects “no”
(display “”), the control returns to the Idle Mode
display. If the operator selects “yes” (display “”)
the control will increment the Moisture Sensor Error
counter and record the error in the queue of the last
eight machine errors and display the Moisture Sensor
Error (display “”), pressing the Back ( )
keypad will clear the error. The “is dryer empty”
prompt will only appear once a day unless machine
power is cycled.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
36
Error Codes
Following is a list of possible error codes for an
electronic control. Errors beginning with “” refer to
external device Infra-red communication errors. All
other errors refer to machine errors.
Cause/
Display
Description
Transmission Failure
Corrective Action
Communication failure. Re-aim external device and try
again.
Device Time-out
Communication failure. Re-aim external device and try
again.
Invalid Command Code
Invalid or Out-of-Range Data
Incorrect machine type. Before downloading, ensure
data is for current machine type.
Incorrect machine type. Before downloading, ensure
data is for current machine type and values entered are
within the minimum and maximum limits.
CRC-16 Error
Communication failure. Re-aim external device and try
again.
Framing Error
Communication error. Re-aim external device and try
again.
Time-out Exceeded
Encryption Error
Communication error. Re-aim external device and try
again.
Incorrect machine type. Before downloading, ensure
data is for current machine type.
Invalid Wake-up or Infra-red Disabled
Communication failure or infra-red is disabled.
Manually enable infra-red on control or re-aim external
device and try again.
Shorted Thermistor Error
Open Thermistor Error
Remove any lint build-up around thermistor. If problem
persists, replace control or thermistor.
Remove any lint build-up around thermistor. If problem
persists, replace control or thermistor.
Airflow Switch Error (Switch Fails to
Open At End of Cycle)
Inspect lint screen and ductwork. Once error is cleared,
control will go back to previous mode of operation.
Airflow Switch Error (Switch Does Not Inspect lint screen and ductwork. Cycle power to
Close After Cycle Starts)
machine (power down, then power up) or push Back ( )
keypad.
Airflow Switch Error (Switch Bounces
During Cycle)
Inspect lint screen and ductwork. Cycle power to
machine (power down, then power up) or push Back ( )
keypad.
Table 8 (continued)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
70444901
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Error Codes
Table 8 (continued)
Cause/
Corrective Action
Display
Description
Machine Did Not Reach Expected
Temperature
Check heating connections, cycle power to machine.
Stove Limit 1 Error
Stove Limit 2 Error
Cabinet Limit Error
Remove any lint build-up around thermostat. If problem
persists, replace control or thermostat.
Remove any lint build-up around thermostat. If problem
persists, replace control or thermostat.
Remove any lint build-up around thermostat. If problem
persists, replace control or thermostat.
ICM Lockout Alarm Active
Rotation Sensor Error
Check for broken or worn belts. Make sure machine is
not over loaded and check if rotation sensor is working.
If problem persists, replace rotation sensor or control.
DIP Switch Configuration Size Mismatch Check temperature index harness and dipswitch settings.
Error
If problem persists, replace temperature index harness or
control.
Fan Motor Contactor Error
Fan Motor Centrifugal Switch Error
Moisture Sensor Error
Check signal to control. If problem persists, replace fan
motor or control.
Check signal to control. If problem persists, replace fan
motor or control.
Push Back ( ) keypad to clear the error.
Table 8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
38
Communications Mode
Infra-red Communications
The Infra-red Communications feature allows the
control to communicate with an external device. The
control can be programmed and have its data read
without using the keypad. It may also be used to start
and stop various diagnostic tests.
How to Begin Communications with An
External Device
The control will go blank and the display will show
“
” until the communication is complete. The
display will return to the previous mode. If an error
occurs that terminates communication, the display will
show the appropriate error code.
NOTE: The Infra-red Communications option
must be turned on.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Download from Www.Somanuals.com. All Manuals Search And Download.
70444901
39
Cycle Charts
Target Moisture
or Time
Cycle No
1
Cycle Name
Cycle Type
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Moisture
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Time Dry
Material Type
Cotton
Bedding
Bedding
Bedding
Bedding
Bedding
Bedding
Synthetic
Blend
Synthetic
Blend
Cotton
Synthetic
Cotton
n/a
Reversing
OFF
ON
Temperature
190°F/88°C
160°F/71°C
190°F/88°C
160°F/71°C
190°F/88°C
190°F/88°C
160°F/71°C
140°F/60°C
160°F/71°C
140°F/60°C
160°F/71°C
190°F/88°C
140°F/60°C
190°F/88°C
190°F/88°C
160°F/71°C
140°F/60°C
n/a
Towels
1%
2
Sheets Blend
5%
3
Sheets Cotton
Sheets Blend Iron
Sheets Cotton Iron
Duvet Cotton
ON
5%
4
ON
20%
5
ON
20%
6
ON
5%
7
Duvet Blend
ON
5%
8
Napkins Synthetic
Napkins Blend
Napkins Synthetic Iron
Napkins Blend Iron
Napkins Cotton Iron
Uniform Perm Press
Uniform Cotton
30 Min High
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
3%
9
3%
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
20%
20%
20%
5%
5%
30 minutes
30 minutes
30 minutes
30 minutes
15 minutes
15 minutes
15 minutes
15 minutes
10 minutes
10 minutes
10 minutes
10 minutes
5 minutes
5 minutes
5 minutes
5 minutes
30 Min Med
n/a
30 Min Low
n/a
30 Min No Heat
15 Min High
n/a
n/a
190°F/88°C
160°F/71°C
140°F/60°C
n/a
15 Min Med
n/a
15 Min Low
n/a
15 Min No Heat
10 Min High
n/a
n/a
190°F/88°C
160°F/71°C
140°F/60°C
n/a
10 Min Med
n/a
10 Min Low
n/a
10 Min No Heat
5 Min High
n/a
n/a
190°F/88°C
160°F/71°C
140°F/60°C
n/a
5 Min Med
n/a
5 Min Low
n/a
5 Min No Heat
n/a
n/a = not applicable
- All cycles include a 2 minute, 100°F (38°C) cool down.
- All cycles with reversing on rotate for 120 seconds and pause for 6 seconds.
- Cool down and reversing settings can be changed from what is pre-programmed from the factory.
- If machine does not have the moisture sensing option, the moisture sensing cycles in the table above are automatically
changed to Auto-Dry cycle type with Dryness Level 0 (zero).
70444901
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
40
Download from Www.Somanuals.com. All Manuals Search And Download.
|