n
Master Station with Selective Door Release
TC-10MD 10-Call Master
TC-20MD 20-Call Master
- SUPPLEMENT TO TC-M INSTRUCTIONS -
The TC-MD Intercom and Selective Door Control System is designed for communication between a central master
station and remote door stations. The TC-MD adds door release to the standard TC-M system. All information
regarding installation other than the external control functions is included in the TC-M instructions. In addition to
communication to remote locations, the Master Station can selectively release the corresponding door strike or
maglock.
WIRING DIAGRAM: SYSTEM USED FOR SELECTIVE DOOR RELEASE
TC-10MD
TB-AD1
For Door #10
IE/IF Door
Station
TB-AD1
For Door #9
1
2
3
~
9
1
2
IE/IF Door
Station
1
2
1
2
1
2
10
E
TC-20MD
N
T
R
+
-
N
T
R
+
-
T
R
12+
12-
M
Door Release button
Located below
C
TRANSFER button.
Relays are activated
when the door
release button is
being pressed while
a station button is
selected.
Momentary Closure for Station #1
RY-PA
#1
1
~
9
BLK
YEL
Momentary Closure for Station #9
Momentary Closure for Station #10
RY-PA
#9
BLK
YEL
BLK
10
L
RY-PA
#10
YEL
Common for each closure
PS-1820UL
To convert RY-PA to N/C (normally
closed) contact: Move one yellow wire
from "NO" to "NC". (Internal
modification, soldering required.)
+
-
AC/
DC
Input
x
x
AC Power
for Door
Releases
Individual Components for System:
TC-MD TERMINAL DEFINITIONS:
TC-nMD
RY-PA
Master station with selective contact output capability (10, 20)
Relay for selective output (1 per station requiring external contact)
18V DC, 2A Power Supply
1 Audio Door Adaptor
10 Audio Door Adaptor
+
-
1~10
E
M,C
T
Power input (18V DC or 16V AC)
Negative
Station number
Common communication
Master-to-Master communication
Transmit to door station
Receive from door station
Output to call extension speaker
PS-1820UL
TB-AD1
TB-AD10
TB-ADM10
IMPORTANT:
1. RY-PA must be used for each selective contact to
isolate AC voltage from the intercom circuit.
2. Extra contact connections and L are on the
external terminal block.
10 Video Door Adaptor
R
S, S
SEPARATE TERMINAL BLOCK LOCATED INSIDE MASTER:
1~10 (20) Selective negative for each channel
L
Common Positive output for selective closure
Pg. 1