Agilent Technologies Laptop 81200 User Manual

Agilent 81200  
The 81200 Data Generator/  
Analyzer Platform  
Configuration Guide  
Release 2.1  
Simplify your verification and characterization process  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Description  
Model Number  
Quantity  
Generator front-ends  
Analyzer front-ends  
Modules  
Generator front-ends 660MHz, RZ/NRZ, 3.5 Vpp, variable transition times SMA (f).  
Generator front-end 330 MHz, RZ/NRZ, variable transition times SMA (f).  
Generator front-end 660 MHz, RZ/NRZ, single channel, 2.5 Vpp SMA (f).  
Dual generator front-end 200 Mbit/s, NRZ, 3.5 VPP SMA (f).  
Agilent E4838A  
Agilent E4842A  
Agilent E4843A  
Agilent E4846A  
Differential analyzer front-end 660 Msa/s, 1 GHz bandwidth, 50SMA (f).  
Single analyzer front-end 660 Msa/s, 1 GHz bandwidth, 50SMA (f).  
Dual analyzer front-end 330 Msa/s, 1 GHz bandwidth, 50SMA (f).  
Agilent E4837A  
Agilent E4844A  
Agilent E4845A  
Agilent E4847A  
High impedance dual analyzer front-end 330 Msa/s, 350 MHz bandwidth, 50SMA (f).  
660 MHz data generator/analyzer module – holds four front-ends, any mix  
660 MHz clock and data generator module – holds two generator front-ends, any mix.  
Clocks up to six Agilent E4841A modules.  
660 MHz central clock module, which clocks up to eleven Agilent E4841A modules  
and up to two Agilent E4805s.  
Agilent E4841A  
Agilent E4831A  
Agilent E4805A  
Required in all systems that include analyzer front-ends, and for all systems with seven  
or more Agilent E4841As.  
Agilent E4805A  
8-line trigger input for TTL signals. When branching on external events  
(hardware signals) other than VXI-ECL trigger lines or compare errors is required.  
Deskewprobe, includes Agilent 1144A 880 MHz active probe and a BNC (f) to SMA (m)  
adapter (part number 1250-1200).  
Agilent E4805A  
Opt 002  
Agilent E4805A  
Opt 003  
Which clock module?  
Front - ends  
Clock module  
Data generator/  
analyzer modules  
+
+
The Agilent E4831A Clock & Data  
Generator Module can be an eco-  
nomic way of building pulse or  
data generators as it includes slots  
for two front-ends. Please remem-  
ber that the Agilent E4831A can  
only be used for generator chan-  
nels. For applications needing  
many channels, analyzer channels  
or more than two looping levels,  
use the Agilent E4805A Central  
Clock Module.  
Generator-only systems.  
(Two looping levels)  
Agilent E4838A 660 MHz/MRZ  
Agilent E4842A 330 MHz RZ/NRZ  
(variable transitions)  
Agilent  
E4831A  
Clock & data  
generator module  
Agilent E4843A 660 MHz RZ/NRZ  
Up to six Agilent E4841A  
modules can be added when  
more generator front-ends are needed.  
Agilent E4846A Dual 200 Mb/s, NRZ  
Generator systems or generator/analyzer systems.  
(Five looping levels)  
Analyzer front ends  
STEP 3: Decision - VXI integration  
or not  
If you want to combine the Agilent  
81200 modules with other VXI  
modules to achieve an "open VXI  
system," then go to STEP 4b.  
Agilent E4837A 660 MSa/s, differential  
+
Agilent E4844A 660 MSa/s  
Agilent E4805A  
Central clock module  
Agilent E4841A  
Data generator/  
analyzer module(s)  
Agilent E4845A Dual 330 MSa/s  
Agilent E4847A High-impedance  
dual 330 MSa/s  
If you want to use the Agilent  
Figure 2: Front-ends and modules  
81200 as a “proprietary system,”  
meaning the Agilent 81200 will not be  
combined with other VXI modules in  
one system, then go to STEP 4a.  
Up to 36 front-ends  
Agilent E4849B  
Up to 8 front-ends  
Agilent E480A  
Embedded PC  
STEP 4a: Selecting the mainframe  
If you’ve made the decision to config-  
ure a "proprietary system," you are  
now in the position to select a main-  
frame. Two mainframes are available,  
the Agilent E4840A small frame with  
three free slots and the Agilent  
E4849B mainframe with 10 free  
slots. Both mainframes include a  
built-in PC running Windows NT  
4.0®. The user software is also  
3-slot PC  
10 free slots  
3 free slots  
+
(+)  
3-slot PC  
VXI bus  
extender  
12 free slots  
VXI bus  
extender  
9 free slots  
12 free slots  
VXI bus  
extender  
installed. All modules and front-ends  
ordered with the mainframes come  
factory installed.  
Figure 3: Mainframes and expanders  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Expander frames  
Product Description  
Model Number  
Quantity  
For more module slots, one or two  
Agilent E4848B expander frames can  
be connected. To do this, a VXI exten-  
der module (Agilent E4849B Opt 002)  
is required. The module occupies one  
of the otherwise free slots and is con-  
nected to a corresponding VXI exten-  
der that is supplied as part of the  
expander frame.  
Mainframes  
Small mainframe – 3 free slots.  
Mainframe – 10 free slots  
VXI extender module (E1482B, 1 slot)  
Required if 1 or 2 expander frames  
are needed  
Agilent E4840A  
Agilent E4849B  
Agilent E4849B  
Opt 002  
Expander frame  
Agilent E4848B  
Software  
Agilent 81200 User Software  
5 licenses of Agilent 81200 User Software  
Agilent E4873A  
Agilent E4873A  
Opt 005  
Note that, when one or two expander  
frames are fitted, an Agilent E4805A  
Central Clock Module must be includ-  
ed in all frames. The Agilent E4831A  
Clock & Data Generator Module is  
unsuitable for systems with expander  
frames.  
Open VXI Interfaces  
VXI Mainframe  
with E1406A GPIB  
Slot 0 Command Module  
VXI Mainframe  
with Agilent E8491A  
IEEE-1394 PC-link to VXI  
Personalized system configuration  
Now you are in a position to config-  
ure your system to meet your specific  
requirements with the Agilent 81200  
Configuration Sheets. For configura-  
tion instructions, please consult the  
box on page 9. If you do not fill out  
the configuration sheets, your system  
will be delivered with the convention-  
al configuration pre-installed. Now go  
to STEP 5.  
Any PC running MS Windows NT 4.0®  
VXI Mainframe  
with National  
Instruments  
VXIpc- 850  
VXI Mainframe  
with Agilent E6235A  
VXI-PC  
STEP 4b: Integrating Agilent 81200  
modules with other VXI test equip-  
ment  
Figure 4: Recommended Standard VXI Interfaces  
To run the Agilent 81200 modules in  
a standard VXI test system with other  
VXI test equipment, it is necessary  
that a controller with the operating  
system Windows NT 4.0® is present,  
on which the Agilent E4873A User  
Software for the Agilent 81200 can  
run. Therefore, either an embedded  
VXI controller, or a Slot 0 command  
module has to be installed in the  
mainframe. The command module  
has to be connected to an external  
PC, on which the Agilent E4873A  
User Software is running. For operat-  
ing the Agilent 81200 platform in a  
VXI test system, the following list,  
comprising of VXI controllers, com-  
mand modules and frames, is recom-  
mended. Please also refer to figure 4.  
Command modules:  
• Agilent E1406A GPIB Slot 0  
command module  
Expander frames  
For more module slots, one or two  
Agilent E4848B expander frames can  
be connected. To do this, a VXI exten-  
der module Agilent E1482B is  
required. The module occupies one of  
the otherwise free slots and is con-  
nected to a corresponding VXI exten-  
der that is supplied as part of the  
expander frame.  
• Agilent E8491B IEEE-1394 PC link  
to VXI  
• National Instruments MXI-2  
Interface  
Frames:  
• Agilent E8403A VXI Mainframe, C-Size  
Note that, when one or two expander  
frames are fitted, an Agilent E4805A  
Central Clock Module must be includ-  
Please consider the power require-  
ment of the modules and front-ends  
when you configure your VXI test sys- ed in all frames. The Agilent E4831A  
tem. For details about power require-  
ments, consult Agilent 81200 Data  
Generator / Analyzer Platform, data  
sheets, p/n 5965-3415E, or download  
the power requirement calculation  
table (MS Excel) for the Agilent 81200  
from:  
Clock & Data Generator Module is  
unsuitable for systems with expander  
frames.  
VXI Controller:  
• Agilent E6235A VXI PC  
• National Instruments VXIpc-850  
It is necessary to order the Agilent  
E4873A User Software for the Agilent  
81200 separately.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
STEP 5: Choosing the user inter-  
face, support options, installation  
options, and test accessories  
User Interface  
The following user interfaces are available  
as Agilent E4840/49B mainframe options:  
The compact choice is the display  
and entry panel that mounts onto the  
front of the mainframe and hinges for  
optimum viewing/connector access. It  
can only be used when connected to  
the frames Agilent E4840A and  
Agilent E4849B in the “proprietary  
system.”  
Option 001 display and entry panel  
Includes 5"x 4" flat VGA display,  
miniature keyboard and touch pad  
Alternatively, a VGA display, PC key-  
board and mouse provide a larger,  
higher resolution display and stan-  
dard-sized keys.  
Option 003/004/005:  
15"/17"/21" Ultra VGA displays  
Support, documentation and rackmount  
options  
Please consult the table below.  
We recommend that a CD-ROM drive  
is ordered so that user software  
upgrades can be installed.  
Option 006 keyboard (U.S./ English)  
and option 007 mouse  
Figure 5: User interfaces  
Product Description  
Model Number  
Quantity  
Agilent E4840A/49B  
Agilent E4840A/49B  
User interface options  
Interface options  
5" x 4" display and entry panel  
Opt 001  
15" VGA monitor  
17" VGA monitor  
21" VGA monitor  
Keyboard, US/English  
Mouse (two button)  
Opt 003  
Opt 004  
Opt 005  
Opt 006  
Opt 007  
Opt 008  
CD-ROM SCSI drive includes SCSI-2 cable and termination  
Documentation options Additional user manual set  
Opt OB1  
Opt ABJ  
Opt OBW  
Japanese localization  
CD-ROM Service Guide (part number E4849-91022)  
Rackmount options  
Support options  
Rack flange kit (part number E8400-80923)  
(Only for the Agilent E4849B and Agilent E4848B)  
Opt AX4  
One year on-site warranty  
Opt W01  
Five year return repair service  
Opt W50  
Software update notification service (12 per year)  
Commercial calibration with test report  
Five year return calibration with service  
Opt +NAO  
Agilent E4805A/31A/41A Opt UK6  
Agilent E4805A/31A/41A Opt W52  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Controlling instruments with the Agilent  
81200 (only for "proprietary systems")  
The embedded PC of the frames  
Agilent E4849B and Agilent E4840A  
includes a GPIB interface so that  
other GPIB instruments can be con-  
trolled with the Agilent 81200 plat-  
form (figure 6). To do this, you need  
to install suitable controller software  
such as C or VEE. The GPIB interface  
also allows the Agilent 81200 to be  
controlled from another computer,  
such as an ATE system controller.  
The supplied GPIB interface  
let's you use the Agilent  
81200's built-in PC as a test  
system controller  
Agilent 81200 (E4840A or E4849B mainframe)  
with Windows-NT -based C,  
HP-Basic or VEE  
Other GPIB instruments  
VXI system  
Other GPIB instruments  
The Agilent 81200 can be  
integrated into a  
GPIB test system  
GPIB  
Communicating over networks (only for  
"proprietary systems")  
Any controller or PC with C,  
C++, HP-BASIC or VEE  
Agilent 81200  
(E4840A or E4849B mainframes)  
The Agilent 81200's PC also includes  
a LAN interface. The Agilent 81200  
can be controlled from a network  
computer and for convenient vector  
transfer, servers may also be accessed  
(figure 6). The data format used for  
transferring vectors is a STIL  
VXI system  
The Agilent 81200 can be  
integrated into LAN's  
LAN  
(Standard Test Interface Language)  
subset (ASCII file with header and  
footer). Vector files can also be trans-  
ferred via 3.5" disks or the optional  
external CD-ROM drive.  
Server/Hard disk  
(STIL subset)  
Agilent 81200 (E4840A  
or E4849B mainframes)  
Figure 6: The Agilent 81200 can be integrated into all common system  
test environments  
Additional test software for automated  
characterization of your design  
Product Description  
Model Number  
Quantity  
If you want to automate your charac-  
terization measurements and create  
shmoo plots, jitter measurements and  
eye diagrams, you can simply install  
the Agilent E4974A Characterization  
Software Components. For details,  
also including the system require-  
ments, please consult Agilent E4974A  
Characterization Software  
Agilent 81200  
dedicated Accessories  
Agilent 81200 Test Fixture  
Agilent E4839A  
Pogo cable kit: 4*SMA(m) & 2 Pogo  
adapter for the Agilent E4839A  
Universal DUT Test Board  
Agilent E4839A  
Opt. 001  
Agilent E4839A  
Opt. 002  
Adapter Kit: 4*SMA(m) I/O Adapter  
Characterisation Software Components  
Cable Kit: 4*SMA(m) to SMA(m)  
Agilent 15440A  
Test Software  
Components, data sheet, p/n 5968-  
4259E.  
General Accessories  
Agilent 15442A  
Cable Kit: 10*SMA(m) to SCI Connector Agilent 15441A  
SMA coax. cable, 1 m.  
Torque wrench, SMA.  
Agilent 8120-4948  
Agilent 8710-1582  
Agilent 15440A  
Agilent 1250-1200  
Agilent 1250-1249  
Agilent 1250-1397  
Agilent 1250-1698  
Agilent 11667B  
Agilent 15433B  
Agilent 15434B  
Agilent 15438B  
Agilent 10833B  
Agilent E2120F  
Adapter Kit: 4* SMA(m) I/O Adapter  
Adapter SMA (m)/BNC (f).  
Adapter right-angle SMA (m-f).  
Adapter right-angle SMA (m-m).  
Adapter tee SMA.  
Pulse adder/splitter, SMA.  
500 ps transition converter.  
1 ns transition converter.  
2 ns transition converter.  
Cable, GPIB.  
VEE 5.0 on CD-ROM.  
BASIC on 3.5" disks.  
Agilent E2060B  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
For more details please consult  
Agilent 81200 Data Generator/  
Analyzer Platform, data sheet, p/n  
5965-3415E.  
DUT Fixturing  
I want to integrate the Agilent 81200 into a  
system. How can I control it and transfer  
test vectors?  
These requirements can be fulfilled  
via LAN or GPIB. Interfaces for both  
are installed on the Agilent 81200  
Controller. The vector file format is a  
STIL subset (Standard Test Interface  
Language; ASCII file with header and  
footer).  
For convenient and reliable DUT fix-  
turing for DUT’s with up to 192 pins,  
there is the Agilent E4839A Test  
Fixture available. For details, please  
consult Agilent E4839A Test Fixture,  
data sheet, p/n 5968-3580E.  
I want to run a PRBS pattern on one chan-  
nel and data from another channel at the  
same time. Is that possible?  
Yes, but you have to use two mod-  
ules, one for the PRBS and one for  
the control signals.  
Simulation data link for VHDL and Verilog  
BestLink/81200, a simulation data  
link is available to process and trans-  
fer simulation data from Verilog and  
VHDL simulators. For details, please  
consult the BestLink/81200  
Simulation Data Link for the Agilent  
81200, product information, p/n  
5968-2548E or visit:  
I want to use just the Agilent 81200 analyzer  
channels. Is this configuration possible?  
Yes, but we recommend that one gen-  
erator channel as a timing reference  
for the system is used, otherwise the  
trigger output would have to be used  
as a timing reference.  
Mainframe/system control and accessories:  
Test accessories  
Please consult the table on page 6.  
I'd like to fit a VXI DVM into a spare slot in  
the Agilent 81200 frame. Will that work?  
Yes, if you have configured the  
Agilent 81200 platform as described  
in the section STEP 4b as an "open"  
system.  
STEP 6: Checking your configuration  
Front-ends and modules:  
What do I need to run generator channels  
up to 1.32 Gbit/s?  
I test my designs in a remote environment  
so I won't need monitors and so on con-  
nected to the Agilent 81200. Will it boot  
without a monitor and keyboard?  
You need two Agilent E4843A or  
Agilent E4838A generator front-ends,  
which are EXOR-ed internally added  
to generate one 1.32 Gbit/s signal. For  
better signal performance, for signals  
above 1 Gbit/s, please also consider  
an external addition, by using an  
Agilent 11667B (APC-3.5 power split-  
ter, DC to 26.5 GHz) or an Agilent  
11636B (DC to 26.5 GHz power  
divider, APC-3.5).  
Yes, but you will need a mouse.  
However, you will need a monitor to  
perform tasks such as shut down and  
to install user software upgrades.  
Can I fit Agilent 81200 modules into an  
existing VXI system?  
Yes, please refer to STEP 4b. Plug and  
play drivers for the Agilent 81200 are  
an integral part of the Agilent  
E4873A Rev. 2.1 User Software.  
For operation in EXOR addition mode  
you only need two Agilent E4843A  
respectively Agilent E4838A front-  
ends per module.  
Can I combine rack & stack instruments  
with the Agilent 81200?  
I need generator channels that operate up  
to 200 Mbit/s and with more than 512 Kbit  
memory depth per channel. Can I use the  
Agilent E4846A dual generator front-ends?  
No. If you need more than 512 Kbit,  
you should use the Agilent  
E4843A/38A (max. 660 Mbit/s) front-  
ends. The Agilent E4846A dual gener-  
ator front-ends share the channel's  
memory depth of 1024 Kbit, this is  
why they only support 512 Kbit. This  
is also true for dual analyzer front-  
ends.  
Yes. You can use an external con-  
troller or you can use the Agilent  
81200's built-in PC as a controller. A  
GPIB (IEEE 488.2) interface is  
already installed on the Agilent 81200  
system controller. You will however,  
need to install controller software  
such as VEE, Agilent HP-BASIC or C.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extensions  
Upgrading an existing Agilent  
81200 data generator/analyzer  
platform  
The Agilent 81200 Data Generator/  
Analyzer Platform can be extended or  
adapted as needed. Front-ends, mod-  
ules and expander frames can be  
added at any time. Orders for individ-  
ual units are supplied with the instal-  
lation instructions.  
Data generator/analyzer  
Example for 16 channels  
• Agilent E4849B mainframe  
• Option 001 display and entry  
panel  
• Agilent E4805A clock module  
• 4 Agilent E4841A modules  
• 8 Agilent E4843A front-ends  
• 8 Agilent E4844A front-ends  
If more than two channels are needed,  
add one or two Agilent E4841A mod-  
ules with up to four front-ends each.  
For data rates below 200 Mbit/s  
(NRZ) the Agilent E4846A dual-out-  
put front-end can be used instead of  
the Agilent E4838A. This can econo-  
mize on the number of front-ends and  
modules required.  
With the above configuration, eight  
data generator channels and eight  
analyzer channels are provided. Other  
mixes are feasible, as the Agilent  
E4841A can accept any mix of front-  
ends.  
User software upgrades  
For data rates up to 660 MHz, the  
Agilent E4843A front-ends should be  
used.  
Revisions and enhancements to the  
user software will be available from  
time-to-time on CD-ROM, for which  
an external CD drive is needed such  
as the Agilent E4840A/49B Opt 008.  
The operating system should not be  
upgraded because the user software  
is specified for operation on Windows  
NT Rev 4.0 US-English localization.  
Data generators  
Requirements  
Similar to those of the pulse/pattern  
generators, additional requirements are:  
Note however, that all front-ends  
within a module have the same  
sequence. Thus, when connecting to  
I/O ports (where analysis must take  
place at a different time from data  
generation), the generator front-ends  
should use different Agilent E4841A  
modules to the analyzer front-ends.  
For more than eight channels, the  
Agilent E4849B mainframe should be  
ordered, instead of the Agilent  
E4840A. For I/O applications where  
there is not enough signal to drive  
25(that is the effective resistance of  
a generator channel connected to an  
Agilent E4844A or Agilent E4845A  
analyzer front-end), the Agilent  
• deep, segmentable, loopable  
memory for generating many  
vectors  
• bus, control and clock signals from  
a single source  
Example configurations (for a "proprietary  
system")  
Here are some example configura-  
tions, providing an overall impression  
of the scope of the Agilent 81200  
Data Generator/Analyzer Platform.  
Example for 20 channels  
• Agilent E4849B mainframe  
• Option 001 display and entry  
panel  
• Agilent E4805A clock module  
• 5 Agilent E4841A modules  
• 20 Agilent E4838A front-ends  
Clock generators, pulse/pattern  
generators  
Requirements  
A single or multi-channel generator  
with:  
• independent phase and duty cycle  
adjustment  
• variable slopes  
• frequency f and f/n simultaneously  
• up to 660 MHz  
E4847A analyzer front-end with selec-  
table high-impedance should be used.  
For data rates below 200 Mb/s, the  
Agilent E4846A dual-output front-end  
can be used instead of the Agilent  
E4838A. This way, control channels  
can be accommodated economically.  
Example configuration  
As an alternative to the display and  
entry panel, a full-size monitor, key-  
board and mouse can be ordered. See  
figure 4 for details.  
• Agilent E4840A three-slot mainframe  
• Option 001 display and entry  
panel  
• Agilent E4831A clock/data generator  
• Two Agilent E4838A front-ends  
• SMA cables (Agilent 15442A)  
Product Description  
Model Number Quantity  
Software  
Agilent 81200 user software  
upgrade to latest revision.  
Agilent E4873A  
Opt 001  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Systems needing more than ten module  
slots  
The Agilent E4849B mainframe can  
be extended using the Agilent E4848B  
expander frame. The maximum con-  
figuration with one expander is:  
3) Select the desired slot for your front-end:  
Each module holds up to four front-  
ends. Make use of the table on page 2  
again and write the product number  
(e.g. E4847A) the kind of front-end  
you would like to have in the appro-  
priate slot. Please note:  
Steps to configure your own per-  
sonal system:  
1) Select the configuration sheets to fill out  
• For configuration of the Agilent  
E4840A Small mainframe, use the  
configuration sheet on page III  
• Agilent E4849B mainframe  
• Option 001 display and entry panel  
(ormonitor/keyboard/mouse  
options)  
• Option 002 VXI extender module  
• Agilent E4805A clock module  
• 8 Agilent E4841A modules  
• 32 front-ends, any mix  
• Agilent E4848B expander frame  
• Agilent E4805A clock module  
• 11 Agilent E4841A modules  
• 44 front-ends, any mix  
• Configuring the Agilent E4849B  
mainframe as a standalone system  
(without the Agilent E4848B  
Expander frames) use the sheet on  
page V  
• Module Agilent E4805A doesn’t  
hold any front-ends  
• Module Agilent E4831A holds only  
two front-ends (only generator  
front-ends) in the 3rd and 4th  
front-end slot  
• Configuring a system with more  
than one frame, use the configura-  
tion sheets on pages VII, IX and XI  
• Module Agilent E4841A holds four  
front-ends  
2) Select the desired slot for your module  
On the 1st row of each sheet you can  
mark with a cross, what kind of mod-  
ule you want to have plugged into  
which slot. For this task, make use of  
the table on page 3 where you have  
already entered your choice of mod-  
ules and front-ends.  
4) Check the power requirements  
The maximum number of front-ends  
for this configuration is 76.  
Checking for power requirements for  
each frame with the power require-  
ment calculation table (MS Excel) is  
useful, to be on the safe-side. The  
power requirement spreadsheet can  
be downloaded from:  
All required connecting cables are  
supplied with the above products.  
SMA cables have to be ordered sepa-  
rately.  
Systems needing more than 19 module slots  
A second expander frame can be con-  
nected. The maximum configuration  
with two expanders is 120 channels.  
5) Fill out the Fax Cover Sheet on the next  
page, and fax it together with the complet-  
ed configuration sheets to the Fax number  
on the cover sheet.  
If in doubt, please contact your local  
Agilent Technologies representative.  
Please make sure that you specify  
your Agilent order number on the fax  
cover sheet, otherwise your personal  
configuration requirement will not be  
processed.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fax  
Cover Sheet  
Agilent 81200 Configuration Guide  
To:  
OFC/BVS Agilent Technologies GmbH,  
Herrenberger Straße 130,  
71034 Böblingen, Germany  
Fax Number: +49 (7031) 464-6532  
If you have problems with this fax, please contact:  
+49 (7031) 464-7674  
From:  
Name:  
Company:  
Telephone:  
Email:  
Sales representative:  
Agilent order no. (mandatory):  
Comments:  
I
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Sheet: E4840A Small Frame  
E4805A  
E4831A  
E4841A  
E4831A  
E4841A  
E4831A  
Please choose one of the front-  
ends:  
E4837A  
E4838A  
E4843A  
E4844A  
E4845A  
E4846A  
E4847A  
and write the product number  
(e.g. E4837A) in the  
appropriate slot  
Slot  
0
1
2
III  
Download from Www.Somanuals.com. All Manuals Search And Download.  
o n t - E n d 4  
o n t - E n d 3  
F r o n t - E n d 2  
F r o n F t - r E n d 1  
F r  
V
Download from Www.Somanuals.com. All Manuals Search And Download.  
o n t - E n d 4  
o n t - E n d 3  
F r o n t - E n d 2  
F r o n F t - r E n d 1  
F r  
VII  
Download from Www.Somanuals.com. All Manuals Search And Download.  
o n t - E n d 4  
o n t - E n d 3  
F r o n t - E n d 2  
F r o n F t - r E n d 1  
F r  
IX  
Download from Www.Somanuals.com. All Manuals Search And Download.  
o n t - E n d 4  
o n t - E n d 3  
F r o n t - E n d 2  
F r o n F t - r E n d 1  
F r  
XI  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Agilent TechnologiesTest and Measurement  
Support, Services, and Assistance  
Related Literature  
Pub. Number  
Agilent Technologies aims to maximize  
the value you receive, while minimizing  
your risk and problems. We strive to  
ensure that you get the test and measure-  
ment capabilities you paid for and obtain  
the support you need. Our extensive sup-  
port resources and services can help you  
choose the right Agilent products for your  
applications and apply them successfully.  
Every instrument and system we sell has  
a global warranty. Support is available  
for at least five years beyond the produc-  
tion life of the product. Two concepts  
underlie Agilent’s overall support policy:  
“Our Promise” and “Your Advantage.”  
Agilent 81200 Data Generator/Analyzer Platform,  
5968-4261E  
brochure  
Agilent 81200 Data Generator/Analyzer Platform,  
5965-3415E  
5968-4259E  
data sheet specifications  
Agilent E4874A Characterization Software  
Components, data sheet  
Our Promise  
Agilent E4839A Test Fixture, data sheet  
5968-3580E  
5968-2548E  
“Our Promise” means your Agilent test  
and measurement equipment will meet its  
advertised performance and functionality.  
When you are choosing new equipment,  
we will help you with product informa-  
tion, including realistic performance spec-  
ifications and practical recommendations  
from experienced test engineers. When  
you use Agilent equipment, we can verify  
that it works properly, help with product  
operation, and provide basic measure-  
ment assistance for the use of specified  
capabilities, at no extra cost upon  
request. Many self-help tools are avail-  
able.  
BestLink/81200 Simulation Data Link for the Agilent  
81200 Data Generator/Analyzer Platform, product  
information  
Data transfer between Design, Simulation and the  
Agilent 81200, product note  
5967-6276E  
5968-8028E  
Flat Panel Display Link Test,  
Your Advantage  
product note  
“Your Advantage” means that Agilent  
offers a wide range of additional expert  
test and measurement services, which you  
can purchase according to your unique  
technical and business needs. Solve prob-  
lems efficiently and gain a competitive  
edge by contracting with us for calibration,  
extra- cost upgrades, out-of-warranty  
repairs, and on-site education and train-  
ing, as well  
For more information, please visit us at:  
as design, system integration, project  
management, and other professional serv-  
ices. Experienced Agilent engineers and  
technicians worldwide can help you maxi-  
mize your productivity, optimize the  
return on investment of your Agilent  
instruments and systems, and obtain  
dependable measurement accuracy for the  
life of those products.  
Get assistance with all your  
test and measurement needs at:  
Or check your local phone book for the  
Agilent office near you.  
Product specifications and descriptions in  
this document subject to change without notice.  
Copyright © 1999, 2000 Agilent Technologies  
Printed in U.S.A. 5/00  
5965-3417E  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ADC Stereo System MMW 100 User Manual
Addonics Technologies Network Card ADN1GPX User Manual
Addtron Technology Switch PR0017 User Manual
Aiphone Home Security System AI 900 User Manual
Air King Ventilation Hood AK965 User Manual
Amcor Air Conditioner CF14000E User Manual
AMD Typewriter x86 User Manual
AMX Network Card Prestige User Manual
Audiovox Automobile Electronics 128 6927 User Manual
Axis Communications Security Camera P3343 User Manual