Acer Altos R920 Series
User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
iii
Notices
FCC declaration of conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
The following local manufacturer/importer is responsible for this declaration:
Product:
Server
Model number:
R920
Name of responsible party:
Address of responsible party:
Acer America Corporation
333 West San Carlos St., San Jose,
CA 95110, U. S. A.
Contact person:
Phone number:
Fax number:
Acer Representative
1-254-298-4000
1-254-298-4147
FCC notice
Class A devices do not have an FCC logo or FCC IDE on the label. Class B devices
have an FCC logo or FCC IDE on the label. Once the class of the device is
determined, refer to the following corresponding statement.
Class A equipment
This device has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be required to
correct the interference at personal expense.
Download from Www.Somanuals.com. All Manuals Search And Download.
iv
However, there is no guarantee that interference will not occur in a particular
installation. If this device does cause harmful interference to radio or television
reception, which can be determined by turning the device off and on, the user
is encouraged to try to correct the interference by one or more of the following
measures:
•
•
•
Reorient or relocate the receiving antenna
Increase the separation between the device and receiver
Connect the device into an outlet on a circuit different from that to which
the receiver is connected
•
Consult the dealer or an experienced radio/television technician for help
Notice: Shielded cables
All connections to other computing devices must be made using shielded cables
to maintain compliance with FCC regulations.
Notice: Peripheral devices
Only peripherals (input/output devices, terminals, printers, etc.) certified to
comply with the Class A limits may be attached to this equipment. Operation
with noncertified peripherals is likely to result in interference to radio and TV
reception.
Caution: Changes or modifications not expressly approved by the
manufacturer could void the user’s authority, which is granted by
the Federal Communications Commission, to operate this server.
Use conditions
This part complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Notice: Canadian users
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Download from Www.Somanuals.com. All Manuals Search And Download.
v
Remarque à l'intention des utilisateurs canadiens
Cet appareil numérique de la classe A est conforme a la norme NMB-003 du
Canada.
Laser compliance statement
The CD or DVD drive used with this computer is a laser product. The CD or DVD
drive's classification label (shown below) is located on the drive.
CLASS 1 LASER PRODUCT
CAUTION: INVISIBLE LASER RADIATION WHEN OPEN. AVOID EXPOSURE TO
BEAM.
APPAREIL A LASER DE CLASSE 1 PRODUIT
LASERATTENTION: RADIATION DU FAISCEAU LASER INVISIBLE EN CAS
D'OUVERTURE. EVITTER TOUTE EXPOSITION AUX RAYONS.
LUOKAN 1 LASERLAITE LASER KLASSE 1
VORSICHT: UNSICHTBARE LASERSTRAHLUNG, WENN ABDECKUNG GEÖFFNET
NICHT DEM STRAHLL AUSSETZEN.
PRODUCTO LÁSER DE LA CLASE I
ADVERTENCIA: RADIACIÓN LÁSER INVISIBLE AL SER ABIERTO. EVITE
EXPONERSE A LOS RAYOS.
ADVARSEL: LASERSTRÅLING VEDÅBNING SE IKKE IND I STRÅLEN.
VARO: LAVATTAESSA OLET ALTTINA LASERSÅTEILYLLE.
VARNING: LASERSTRÅLNING NÅR DENNA DEL ÅR ÖPPNAD ÅLÅ TUIJOTA
SÅTEESEENSTIRRA EJ IN I STRÅLEN.
VARNING: LASERSTRÅLNING NAR DENNA DEL ÅR ÖPPNADSTIRRA EJ IN I
STRÅLEN.
ADVARSEL: LASERSTRÅLING NAR DEKSEL ÅPNESSTIRR IKKE INN I STRÅLEN.
Macrovision copyright protection notice
"U.S Patent Nos. 4,631,603; 4,819,098; 4,907,093; 5,315,448; and 6,516,132."
This product incorporates copyright protection technology that is protected by
U.S. patents and other intellectual property rights. Use of this copyright
protection technology must be authorized by Macrovision, and is intended for
home and other limited viewing uses only unless otherwise authorized by
Macrovision. Reverse engineering or disassembly is prohibited.
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
CE Declaration of conformity
We,
Acer Computer (Shanghai) Limited
3F, No. 168 Xizang Medium Road, Huangpu District,
Shanghai, China
Contact Person: Mr. Easy Lai
Tel: 886-2-8691-3089
Fax: 886-2-8691-3120
E-mail: easy_lai@acer.com.tw
Hereby declare that:
Product:
Server
Trade name:
Model number:
SKU number:
Acer
R920
R920xx ("x" = 0~9, a~z, A~Z or blank)
Is compliant with the essential requirements and other relevant provisions of
the following EC directives, and that all the necessary steps have been taken
and are in force to assure that production units of the same product will
continue to comply with these requirements.
•
EMC Directive 2004/108/EC, amended by conformity with the
following harmonized standards:
•
•
•
•
EN55022:1998 + A1:2000 + A2:2003, AS/NZS CISPR22:2002, Class A
EN55024:1998 + A1:2001 + A2:2003
EN61000-3-2:2000 + A2:2005, Class D
EN61000-3-3:1995 + A1:2001
•
•
Low Voltage Directive 2006/95/EC as attested by conformity with
the following harmonized standard:
•
EN60950-1:2001 + A11:2004
RoHS Directive 2002/95/EC on the Restriction of the Use of certain
Hazardous Substances in Electrical and Electronic Equipment
Director, Acer Computer (Shanghai) Limited
Download from Www.Somanuals.com. All Manuals Search And Download.
vii
Declaration of conformity for EU countries
Hereby, Acer, declares that this PC series is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
Russian regulatory certification compliance
Download from Www.Somanuals.com. All Manuals Search And Download.
viii
Information for your safety and
comfort
Safety instructions
Read these instructions carefully. Keep this document for future reference.
Follow all warnings and instructions marked on the product.
Turning the product off before cleaning
Unplug this product from the wall outlet before cleaning. Do not use liquid
cleaners or aerosol cleaners. Use a damp cloth for cleaning.
CAUTION for plug as disconnecting device
Observe the following guidelines when connecting and disconnecting power to
the power supply unit:
•
•
•
Install the power supply unit before connecting the power cord to the AC
power outlet.
Unplug the power cord before removing the power supply unit from the
server.
If the system has multiple sources of power, disconnect power from the
system by unplugging all power cords from the power supplies.
CAUTION for accessibility
Be sure that the power outlet you plug the power cord into is easily accessible
and located as close to the equipment operator as possible. When you need to
disconnect power to the equipment, be sure to unplug the power cord from the
electrical outlet.
Usage warnings
•
•
•
Do not use this product near water. Never spill liquid of any kind onto or
into the product.
Do not place this product on an unstable cart, stand or table. If the product
falls, it could be seriously damaged.
Slots and openings are provided for ventilation to ensure reliable
operation of the product and to protect it from overheating. These
openings must not be blocked or covered. The openings should never be
blocked by placing the product on a bed, sofa, rug or other similar surface.
This product should never be placed near or over a radiator or heat
register, or in a built-in installation unless proper ventilation is provided.
Download from Www.Somanuals.com. All Manuals Search And Download.
ix
•
Never push objects of any kind into this product through cabinet slots as
they may touch dangerous voltage points or short-out parts that could
result in a fire or electric shock.
•
•
To avoid damage of internal components and to prevent battery leakage,
do not place the product on a vibrating surface.
Never use it under sporting, exercising, or any vibrating environment
which will probably cause unexpected short current or damage rotor
devices, hard drives, optical drives, and even exposure risk from lithium
battery pack.
Using electrical power
•
This product should be operated from the type of power indicated on the
marking label. If you are not sure of the type of power available, consult
your dealer or local power company.
•
•
Do not allow anything to rest on the power cord. Do not locate this
product where people will walk on the cord.
If an extension cord is used with this product, make sure that the total
ampere rating of the equipment plugged into the extension cord does not
exceed the extension cord ampere rating. Also, make sure that the total
rating of all products plugged into the wall outlet does not exceed the fuse
rating.
•
•
Do not overload a power outlet, strip or receptacle by plugging in too
many devices. The overall system load must not exceed 80% of the branch
circuit rating. If power strips are used, the load should not exceed 80% of
the power strip's input rating.
This product's power supply is equipped with a three-wire grounded plug.
The plug only fits in a grounded power outlet. Make sure the power outlet
is properly grounded before inserting the power supply plug. Do not insert
the plug into a non-grounded power outlet. Contact your electrician for
details.
Warning! The grounding pin is a safety feature. Using a
power outlet that is not properly grounded may result in
electric shock and/or injury.
Note: The grounding pin also provides good protection from
unexpected noise produced by other nearby electrical devices that
may interfere with the performance of this product.
Download from Www.Somanuals.com. All Manuals Search And Download.
x
•
Use the product only with the supplied power supply cord set. If you need
to replace the power cord set, make sure that the new power cord meets
the following requirements: detachable type, UL listed/CSA certified, type
SPT-2, rated 7 A 125 V minimum, VDE approved or its equivalent, 4.6
meters (15 feet) maximum length.
Safe listening
Follow these instructions, suggested by hearing experts, to protect your
hearing.
•
Gradually increase the volume until you can hear it clearly and comfortably
and without distortion.
•
•
•
•
After setting the volume level, do not increase it after your ears adjust.
Limit the amount of time listening to music at high volume.
Avoid turning up the volume to block out noisy surroundings.
Turn the volume down if you can't hear people speaking near you.
Product servicing
Do not attempt to service this product yourself, as opening or removing covers
may expose you to dangerous voltage points or other risks. Refer all servicing to
qualified service personnel.
Unplug this product from the wall outlet and refer servicing to qualified service
personnel when:
•
•
•
•
•
the power cord or plug is damaged, cut or frayed
liquid was spilled into the product
the product was exposed to rain or water
the product has been dropped or the case has been damaged
the product exhibits a distinct change in performance, indicating a need
for service
•
the product does not operate normally after following the operating
instructions
Note: Adjust only those controls that are covered by the
operating instructions, since improper adjustment of other
controls may result in damage and will often require extensive
work by a qualified technician to restore the product to normal
condition.
Download from Www.Somanuals.com. All Manuals Search And Download.
xi
Disposal instructions
Do not throw this electronic device into the trash when discarding. To minimize
pollution and ensure utmost protection of the global environment, please
Equipment (WEEE) regulations, visit
Download from Www.Somanuals.com. All Manuals Search And Download.
xii
Tips and information for comfortable use
Computer users may complain of eyestrain and headaches after prolonged use.
Users are also at risk of physical injury after long hours of working in front of a
computer. Long work periods, bad posture, poor work habits, stress, inadequate
working conditions, personal health and other factors greatly increase the risk
of physical injury.
Incorrect computer usage may lead to carpal tunnel syndrome, tendonitis,
tenosynovitis or other musculoskeletal disorders. The following symptoms may
appear in the hands, wrists, arms, shoulders, neck or back:
•
•
•
•
•
numbness, or a burning or tingling sensation
aching, soreness or tenderness
pain, swelling or throbbing
stiffness or tightness
coldness or weakness
If you have these symptoms, or any other recurring or persistent discomfort
and/or pain related to computer use, consult a physician immediately and
inform your company's health and safety department.
The following sections provide tips for more comfortable computer use.
Finding your comfort zone
Find your comfort zone by adjusting the viewing angle of the monitor, using a
footrest, or raising your sitting height to achieve maximum comfort. Observe
the following tips:
•
•
•
Refrain from staying too long in one fixed posture.
Avoid slouching forward and/or leaning backward.
Stand up and walk around regularly to remove the strain on your leg
muscles.
•
•
•
Take short rests to relax your neck and shoulders.
Avoid tensing your muscles or shrugging your shoulders.
Install the external display, keyboard and mouse properly and within
comfortable reach.
•
If you view your monitor more than your documents, place the display at
the center of your desk to minimize neck strain.
Download from Www.Somanuals.com. All Manuals Search And Download.
xiii
Taking care of your vision
Long viewing hours, wearing incorrect glasses or contact lenses, glare, excessive
room lighting, poorly focused screens, very small typefaces and low-contrast
displays could stress your eyes. The following items provide suggestions on how
to reduce eyestrain.
•
Eyes
•
•
Rest your eyes frequently.
Give your eyes regular breaks by looking away from the monitor and
focusing on a distant point.
•
Blink frequently to keep your eyes from drying out.
•
Display
•
•
Keep your display clean.
Keep your head at a higher level than the top edge of the display so
your eyes point downward when looking at the middle of the display.
•
•
Adjust the display brightness and/or contrast to a comfortable level
for enhanced text readability and graphics clarity.
Eliminate glare and reflections by:
– placing your display in such a way that the side faces the window or
any light source
–
–
–
–
–
minimizing room light by using drapes, shades or blinds
using a task light
changing the display's viewing angle
using a glare-reduction filter
using a display visor, such as a piece of cardboard extended from
the display's top front edge
•
•
Avoid adjusting your display to an awkward viewing angle.
Avoid looking at bright light sources, such as open windows, for
extended periods of time.
Download from Www.Somanuals.com. All Manuals Search And Download.
xiv
Developing good work habits
Develop the following work habits to make your computer use more relaxing
and productive:
•
•
•
•
Take short breaks regularly and often.
Perform some stretching exercises.
Breathe fresh air as often as possible.
Exercise regularly and maintain a healthy body.
Warning! We do not recommend using the computer on a
couch or bed. If this is unavoidable, work for only short
periods, take breaks regularly, and do some stretching
exercises.
Download from Www.Somanuals.com. All Manuals Search And Download.
Notices
FCC declaration of conformity
iii
Laser compliance statement
Macrovision copyright protection notice
CE Declaration of conformity
v
Declaration of conformity for EU countries
Information for your safety and comfort
Safety instructions
Tips and information for comfortable use
1 System tour
Features summary
External and internal structure
Front bezel
Front panel
Rear panel
Internal components
System boards
Mainboard
Memory board
Control panel
LCD control panel (optional)
System LED indicators
Control panel LED indicators
Hot-plug HDD carrier LED indicators
Hot-swap fan module LED indicators
Hot-plug power supply module LED indicators
Hot-plug PCI Express slot LED indicators
Memory board LED indicators
System jumpers
19
22
2 System setup
29
31
31
32
33
34
35
36
Setting up the system
Pre-installation requirements
Connecting peripherals
Turning on the system
Power-on problems
Configuring the system OS
Turning off the system
Download from Www.Somanuals.com. All Manuals Search And Download.
xvi
3 System upgrade
68
82
83
Installation precautions
ESD precautions
Pre-installation instructions
Post-installation instructions
Opening the server
Removing and installing the processor air baffle
Configuring hot-pluggable components
Removing and installing a hard disk drive
Configuring cold-pluggable components
Installing a 5.25-inch drive
Upgrading the processor
Installing and removing DIMM modules
Removing and installing a non-hot-plug PCI card
Configuring server management components
Installing and removing the I/O expansion module
Installing and removing the ARMC/3 R2 module
Configuring the hardware RAID components
Installing and removing the SAS module
Installing and removing the RAID activation key
and RAID cache
Installing and removing the RAID BBU
4 System BIOS
BIOS overview
Entering BIOS setup
BIOS setup menus
BIOS setup keyboard commands
Main menu
101
102
104
105
107
111
112
113
115
Advanced menu
Processor Configuration
Memory Configuration
Mass Storage Controller Configuration
Serial Port Configuration
USB Configuration
PCI Configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
LAN Configuration
System Acoustic and Performance Configuration
Security menu
Server Management menu
Console Redirection
System Information
Intel Remote Management Module Information
Boot Options menu
Boot Manager menu
Error Manager menu
Exit menu
123
127
Upgrading the BIOS
Troubleshooting
137
139
Resetting the system
Problems following initial system installation
First steps checklist
Hardware diagnostic testing
Verifying proper operation of key system lights
Specific problems and corrective actions
Rack installation information
Rack mount configuration
Vertical mounting hole pattern
Installing the system into the rack
Appendix B: Memory configuration
Introduction
Memory board installation order
FBDIMM module population order
Memory configuration
163
165
167
171
172
173
175
Dual-channel mode
Single-channel mode
Memory sparing mode
Memory mirroring mode
Appendix C: SAS and SAS RAID
configuration utilities
Overview
177
179
Download from Www.Somanuals.com. All Manuals Search And Download.
xviii
SAS configuration utility
SAS RAID configuration utility
180
182
Index
185
Download from Www.Somanuals.com. All Manuals Search And Download.
The Altos R920 is a powerful, feature-rich platform
designed to deliver superior performance,
scalability, and flexibility to meet the needs of
various network environments. It is specially suited
for minimizing system downtime and maintaining
mission critical applications accessible.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Features summary
This section lists the impressive computing features of the Altos R920
system.
Processor
•
Supports one to four physical processors
®
•
•
Quad-core Intel Xeon™ processors 7300 series
®
Dual-core Intel Xeon™ processors 7200 series
®
•
•
64-bit Intel Xeon™ processors with 2 x 4 MB L2 cache
1066 MHz front side bus
1
•
Support for the following Intel technologies :
•
•
•
•
•
•
Extended Memory 64-bit Technology
Enhanced Intel SpeedStep Technology
Demand-Based Switching for power savings
Execute-disable bit for hardware support of security features
Intel Virtualization Technology
Enhanced power and thermal management
Chipset
•
•
Intel 7300 Chipset Memory Controller Hub (north bridge)
Intel Enterprise South Bridge 2 (ESB2) I/O Controller (south bridge)
Memory subsystem
•
Supports up to 128 GB of DDR2-667 MHz (PC2-5300) fully buffered
DIMM (FBDIMM) memory modules
•
Supports one to four removable memory boards
•
Each memory board supports:
-
-
-
Eight FBDIMM slots
A fault LED to report DIMM failures and error conditions
Connection through x16 PCI-Express slots
1
site at http://www.intel.com/products/processor/xeon7000/index.htm.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
4
•
Memory reliability, availability, and serviceability (RAS)
features
-
-
-
Memory scrub engine
Memory mirroring
Memory sparing
Note: For more information on system RAS features, refer to
“Appendix B: Memory configuration” on page 163.
Media storage
•
One 5.25-inch device bay supports:
•
•
•
DAT 160 tape drive
AIT-2 tape drive
LT0-3 half-height tape drive
•
Up to eight hot-plug drive carriers
2.5-inch SAS hard disk drives
•
SAS controller
•
•
LSI 1078 SAS controller
Supports RAID levels 0, and 1
Integrated hardware RAID (optional)
•
Supports RAID levels 0, 1, 5, 6, 10, 50, and 60 with installation of
the following components:
•
•
•
RAID activation key (iButton)
DDR2-667 registered ECC DIMM for RAID cache
RAID Battery Backup Unit (BBU). Available as an upgrade
option.
Serial ATA port
•
•
Two internal 7-pin vertical SATA ports
Supports transfer rate of up to 3.0 GB/s
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Networking
•
•
•
Intel ESB2 I/O controller
Intel 82563EB Gigabit Ethernet controller with dual ports
Intel 82575 Gigabit Ethernet controller with dual ports (optional
I/O expansion module)
•
•
Supports Intel I/O Acceleration Technology
Supports boot from integrated SCSI (iSCSI)
PCI- Express I/O
•
•
•
Two hot-plug x8 PCI Express slot
Two x8 PCI Express slot
Three x8 PCI Express slots (with x4 throughput)
Note: The PCI hot-plug function allows the removal of a standard
PCI adapter from the system without stopping the software or
powering down the unit.
Graphic interface
®
•
ATI ES1000 video controller with 32 MB video RAM
Server management
•
•
Integrated Trusted Platform Module (TPM)
Integrated Baseboard Management Controller (BMC) module
•
Intelligent Platform Management Interface (IPMI) 2.0
compliant
•
In-band and out-band server management
•
Acer Remote Management Card/3 Revision 2 (ARMC/3 R2) module
(optional)
•
•
•
High performance KVM redirection
Includes a dedicated NIC port
USB mouse, keyboard, and media redirection
Control panel
•
•
Button control panel
LCD control panel (optional)
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
6
I/O ports
•
•
Front
•
VGA/monitor port
•
Three USB 2.0 ports
Rear
•
•
•
•
Serial port
VGA/monitor port
Two USB 2.0 ports
Four Gigabit LAN ports (RJ-45) (two ports optional)
2
•
Server management port (RJ-45)
Operating system and software
• Operating system options:
®
®
•
•
•
•
•
•
Microsoft Windows Server 2003, x64 Edition
®
®
Microsoft Windows Server 2003
®
Red Hat Enterprise Linux 5.0
®
Red Hat Enterprise Linux 5.0, EM64T
®
SUSE Linux Enterprise Server 10.0
®
SUSE Linux Enterprise Server 10.0, EM64T
•
Server management utilities and applications
3
•
Acer Server Manager (ASM)
3
•
•
Acer EasyBUILD™ (includes SAS RAID Configuration Utility)
Acer eBusiness Value Pack
2
Reserved for remote management of server. This requires installation of an
ARMC/3 R2 module.
3
For more information on how to install and use ASM and EasyBUILD utilities,
refer to the manual on the EasyBUILD DVD.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
8
External and internal structure
Front bezel
The front bezel provides an interface for system management via
status LED indicators. The light pipes on the backside of the front bezel
allow the system status LEDs to be monitored when the front bezel is
closed.
The front bezel is removable to allow access to server’s hard drives,
peripheral device, and control panel. For details on how to remove the
front bezel, see “To remove the front bezel” on page 41.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
10
Rear panel
A
4
B
C
1
2
3
5
6
7
I
K
N
D
G
H
L
M
E
F
J
Item
Component
A1 - A7
A1 Hot-plug PCI Express x8 slot
A2 Hot-plug PCI Express x8 slot
A3 PCI Express x8 slot
A4 PCI Express x8 slot
A5 PCI Express x8 slot (with x4 throughput)
A6 PCI Express x8 slot (with x4 throughput)
A7 PCI Express x8 slot (with x4 throughput)
B
ARMC/3 R2 Ethernet port*
I/O expansion module Ethernet ports
USB 2.0 ports
C
D
E
VGA/monitor port
F
Serial port
G, K
H, L
I
Power supply indicators
AC input power connector
I/O expansion module (optional)
Gigabit LAN ports (10/100/1000 Mbps)
System ID button
J
M
N
System ID indicator
* Reserved for remote management of server. This requires installation of an ARMC/3 R2
module.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
12
System boards
Mainboard
The mainboard becomes accessible once you open the system. It should
look like the figure shown below.
D
A
H
J
M
B
C
E
F
G
I
K
L
CC
BB
AA
N
O
Z
Y
X
W
V
P
Q
T
S
R
U
Item Description
Item Description
A
B
Dual Ethernet ports
I/O expansion module slot
P
Front panel connector
Q
Power distribution board (PDB)
signal connector
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Item Description
Item Description
C
PCI Express x8 (with x4
R
CPU socket 1
throughput) - (slot 7)
D
E
Serial port A (internal)
S
CPU socket 2
CPU socket 3
PCI Express x8 (with x4
throughput) - (slot 6)
T
F
PCI Express x8 (with x4
throughput) - (slot 5)
U
CPU socket 4
G
H
I
PCI Express x8 (slot 4)
PCI Express x8 (slot 3)
V
SAS module slot
Chassis intrusion
Internal USB port*
W
X
Hot-plug PCI Express x8
(slot 2)
J
Hot-plug PCI Express x8
(slot 1)
Y
Memory board slot C
K
L
Serial port B
VGA port
Z
SATA connectors
AA
BB
Memory board slot D
Real-time clock battery
M
USB 1 (top)
USB 2 (bottom)
N
O
Memory board slot A
Memory board slot B
CC
Trusted Platform Module (U2D1)
* Reserved for tape drives.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
14
Memory board
The memory board connects to the mainboard through x16 PCI Express
slots.
H
F
D
B
A
I
G
E
C
Q
P
O
N
M
L
K
J
Item
Description
Item
Description
DIMM 1 slot
DIMM 2 slot
DIMM 3 slot
DIMM 4 slot
DIMM 5 slot
DIMM 6 slot
DIMM 7 slot
DIMM 8 slot
A
B
C
D
E
F
Power good indicator
DIMM 1 fault indicator
DIMM 2 fault indicator
DIMM 3 fault indicator
DIMM 4 fault indicator
DIMM 5 fault indicator
DIMM 6 fault indicator
DIMM 7 fault indicator
DIMM 8 fault indicator
J
K
L
M
N
O
P
G
H
I
Q
Download from Www.Somanuals.com. All Manuals Search And Download.
15
Control panel
The Altos R920 system supports either the button control panel,
providing basic functionality, or the LCD control panel, which adds
additional server management features. Both control panels utilize a
combination of control buttons, status LED indicators, along with I/O
ports, to centralize system control, monitoring, and accessibility.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
16
Button control panel
Item
Icon
Component
A
HDD (hard disk drive) activity indicator
B
LAN1 status indicator displays network activity in either
LAN ports on the mainboard.
LAN2 status indicator displays network activity in either
LAN ports on the optional I/O expansion module.
C
Status/fault indicator
Power indicator
D
E
F
System ID indicator
System ID button
Power button
G
H
Reset button
Download from Www.Somanuals.com. All Manuals Search And Download.
17
LCD control panel (optional)
Item
Icon
Component
A
B
C
D
E
LCD display
Scroll up button
Scroll down button
Back button
Select button
F
System ID indicator
G
H
Power indicator
Power button
I
Status/fault indicator
J
LAN1 status indicator displays network activity in either
LAN ports on the mainboard.
LAN2 status indicator displays network activity in either
LAN ports on the optional I/O expansion module.
K
L
HDD (hard disk drive) activity indicator
Reset button
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
18
Control panel button function overview
The following table list and describe the function of the control
buttons available on the control panel.
Control button
Function
NMI button
Puts the server in a halt-state for diagnostic purposes
and allows you to issue a non-maskable interrupt.
After using the interrupt, a memory download can be
performed to determine the cause of the problem.
Reset button
Reboots and initializes the system.
Power/sleep button
Toggles the system power on and off. This button also
functions as a sleep button if enabled by an ACPI-
compliant operating system.
System ID button
Toggles the front panel ID LED and the mainboard
system ID LED on and off. The mainboard system ID
LED is visible through the rear of the chassis and
allows you to locate the server you’re working on
from behind a rack of servers.
Scroll up button
Scroll down button
Back button
With an LCD control panel, use these navigation
buttons to do the following.
•
•
Navigate through the menu options.
Select an option in the menu and confirm your
selection.
Select button
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
20
Control panel LED indicators
The following table list and describe the LED indicators available on
the mini or optional full-function control panel.
LED
indicator
LED
status
System
status
Item
Color
Description
A
HDD
activity
Green
On
—
HDD is installed and
functioning correctly.
Note: LED may blink
if all drives are active
at the same time.
Green
Blinking
—
—
HDD is active.
Amber On
HDD or HDD slot
failure.
Amber Slow
—
—
A predictive HDD or
HDD slot failure or
rebuild is in process.
blinking
(~1 Hz)
Amber Fast
HDD rebuild is
interrupted or
rebuild on empty
slot.
blinking
(~2.5
Hz)
Download from Www.Somanuals.com. All Manuals Search And Download.
21
LED
indicator
LED
status
System
status
Item
Color
Description
B
LAN1,
LAN2
status
Green
On
•
LAN1
active
•
Network activity
in either LAN
ports on the
mainboard.
•
LAN2
active
•
Network activity
in either LAN
ports on the
optional I/O
expansion
module.
Green
—
Blinking Active
Network access
No activity
Off
Off
Idle
C
Status/
fault
·—
Not Ready
•
•
AC power off
POST error
Green
Green
On
Ready
System booted and
ready.
Blinking Degraded
•
•
System is in a
degraded state.
Processor or DIMM
disabled.
Amber On
Critical
condition
•
•
System failure.
Critical power
supply, blower,
voltage, or
temperature
failure.
Amber Blinking Non-
critical
condition
•
•
Redundant power
supply or blower
failure.
Non-critical
blower, voltage,
and temperature
failure.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
22
LED
indicator
LED
status
System
status
Item
D
Color
Description
Power
—
Off
On
Off
Power off
Power on
S4/S5
System is not
powered on.
Green
—
System has power
applied to it.
System in ACPI S4 or
S5 state (power off).
Green
Green
Blinking S1
System in ACPI S1
state (sleep mode).
On
S0
System in ACPI S0
state (legacy power
on).
E
System ID
Blue
—
On
—
—
System identification
is active.
Off
Identification is
disabled.
Hot-plug HDD carrier LED indicators
A
B
Item
Color
Status
Description
A
Amber
Flashing
HDD is not powered on and has a fault
condition.
Amber+ Alternate
green flashing
•
•
HDD is powered on and rebuilding RAID.
HDD is powered on and has a fault
condition.
Download from Www.Somanuals.com. All Manuals Search And Download.
23
Item
Color
Status
On
Description
B
Green
HDD is installed and working correctly.
HDD is active.
Flashing
Off
•
•
No HDD is installed.
HDD is initiated but has no current
activity.
Hot-swap fan module LED indicators
LED
Color
Status
Description
indicator
Fan good
Fan fault
—
Off
On
Fan normal operation.
Amber
Fan failure (Non-critical condition).
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
24
Hot-plug power supply module LED indicators
LED
indicator
Item
Color
Status Description
A
B
Power good Green
On
On
System has power applied to it.
Fault
Amber
Green
•
•
Power rail failure.
Power supply is in a latched
state.
C
AC OK
On
AC power cord is plugged into an
active AC power source.
Download from Www.Somanuals.com. All Manuals Search And Download.
25
LAN port LED indicators
A
B
LED
indicator
Item
Color
Status
Description
A
Status
Green
On
Network link is detected.
No network connection.
Network connection in place.
10 Mbps connection
Off
Blinking
Off
B
Speed
—
Green
Amber
On
100 Mbps connection
On
1000 Mbps connection
Hot-plug PCI Express slot LED indicators
The PCI slots 1 and 2 have a LED indicator to display the PCI hot-plug
status.
LED
indicator
Color
Status
Description
Power
Off
Power off
All main rails are removed from the
slot. Card can be inserted or removed.
Green,
on
Power on
PCI slot 1 or 2 is powered on. Card
cannot be inserted or removed.
Green,
blinking
Power
transition
PCI slot 1 or 2 is in the process of
changing state. Card cannot be
inserted or removed.
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
26
LED
indicator
Color
Status
Description
Attention
Off
Normal
Normal operation
Amber,
on
Attention
Power failure or operational problem
at the slot.
Amber,
Locate
Slot is being identified.
blinking
Memory board LED indicators
The LEDs on the memory board indicate the status of the memory
board power and DIMM.
H
F
D
B
A
I
G
E
C
Item
LED indicator
Color
Description
A
Power good
Green,
on
Power is detected.
The memory board power is good.
Off
Power is not detected on all boards.
B-I
DIMM 1 to 8
fault
Amber,
on
DIMM installed in DIMM slots is
malfunctioning and needs to be
replaced.
Off
DIMM is functioning properly.
Download from Www.Somanuals.com. All Manuals Search And Download.
27
System jumpers
A
C
D
E
F
B
Item
Name
Location
Default
Settings
A
Rolling BIOS
J3D1
1-2 (Empty)
2-3 (Stuff)
Force other bank
Normal mode
B
C
D
Password
disable or clear
J3C2
J3C3
J5C1
1-2 (Stuff)
Password protect
2-3 (Empty)
Password disabled/
cleared
Clear CMOS/
NVRAM
1-2 (Stuff)
Normal
2-3 (Empty)
Forced CMOS/
NVRAM clear
BMC force
update
1-2 (Stuff)
Disable BMC force
update
Enable BMC force
update
2-3 (Empty)
Download from Www.Somanuals.com. All Manuals Search And Download.
1 System tour
28
Item
Name
Location
Default
Settings
E
F
BMC flash write
protect
J6D1
1-2 (Stuff)
Disable flash write
protect
Enable flash write
protect
2-3 (Empty)
Circuit breaker
J6F1
1-2 (Empty)
2-3 (Stuff)
20 A/110 V (USA)
15 A/100 V (Japan)
Download from Www.Somanuals.com. All Manuals Search And Download.
This chapter gives you instructions on how to set up
the system. Procedures on how to connect
peripherals are also explained.
Download from Www.Somanuals.com. All Manuals Search And Download.
31
Setting up the system
Pre-installation requirements
Selecting a site
Before unpacking and installing the system, select a suitable site for
the system for maximum efficiency. Consider the following factors
when choosing a site for the system.
•
•
•
•
•
Near a grounded power outlet
Clean and dust-free
Stable surface free from vibration
Well-ventilated and away from sources of heat
Secluded from electromagnetic fields produced by electrical
devices such as air conditioners, radio and TV transmitters, etc.
Checking the package contents
Check the following items from the package:
•
•
•
•
Acer Altos R920 system
Acer EasyBUILDTM
Acer eBusiness ValuePack
Acer Altos R920 accessory box
If any of the above items are damaged or missing, contact your dealer
immediately.
Save the boxes and packing materials for future use.
Download from Www.Somanuals.com. All Manuals Search And Download.
2 System setup
32
Connecting peripherals
Refer to the illustration below for specific connection instructions on
the peripherals you want to connect to the system.
110/220 V
110/220 V
Note: Consult the operating system manual for information on
how to configure the network setup.
Download from Www.Somanuals.com. All Manuals Search And Download.
33
Turning on the system
After making sure that you have properly set up the system, applied
power, and connected all the necessary peripherals, you can now
power on the system.
1
Remove the front bezel.
2
Press the power button.
3
The system starts up and displays a welcome message on the
monitor. After that, a series of power-on self-test (POST) messages
appear. The POST messages indicate if the system is running well
or not.
Download from Www.Somanuals.com. All Manuals Search And Download.
2 System setup
34
Note: If the system does not turn on or boot after pressing the
power button, go to the next section for the possible causes of the
boot failure.
If the POST finds any problems, the system will emit a beep code
followed by an error message displayed on the monitor. Aside from the
POST messages, you can determine if the system is in good condition
by checking if the following occurred.
•
•
The power indicator on the control panel lights up green.
The Num Lock, Caps Lock, and Scroll Lock indicators on the
keyboard light up.
Power-on problems
If the system does not boot after you have applied power, check the
following factors that might have caused the boot failure.
•
The external power cable may be loosely connected.
Check the power cable connection from the power source to the
power cable socket on the rear panel. Make sure that the cable is
properly connected to the power source and to the power cable
socket.
•
•
No power comes from the grounded power outlet.
Have an electrician check your power outlet.
Loose or improperly connected internal power cables.
Check the internal cable connections. If you are not confident to
perform this step, ask a qualified technician to assist you.
Warning! Make sure all power cords are disconnected from
the electrical outlet before performing this task.
Note: If you have gone through the preceding actions and the
system still fails to boot, ask your dealer or a qualified technician
for assistance.
Download from Www.Somanuals.com. All Manuals Search And Download.
35
Configuring the system OS
The Altos R920 system comes with Acer EasyBUILD that allows you to
conveniently install your choice of operating system. To start using
EasyBUILD, follow the steps below.
1
2
Locate the EasyBUILD DVD included in the system package.
With the system turned on, gently press the DVD drive Stop/Eject
button.
3
4
When the disc tray slides open, insert the EasyBUILD DVD with the
label or title side of the disc facing upward.
Note: When handling the disc, hold it by the edges to avoid
smudges or fingerprints.
Gently press the disc down to make sure that it is properly
inserted.
Caution! While pressing the disc, be careful not to bend the disc
tray. Make sure that the disc is properly inserted before closing
the disc tray. Improper insertion may damage both the disc and
the DVD drive.
5
6
Gently press the drive Stop/Eject button again to close the disc
tray.
The Acer EasyBUILD sequence begins. Follow all onscreen
instructions.
For more information, refer to the Acer EasyBUILD Installation guide.
Note: Windows or Linux OS CD is needed when you install the OS
with the EasyBUILD DVD.
Download from Www.Somanuals.com. All Manuals Search And Download.
2 System setup
36
Turning off the system
There are two ways to turn off the server—via software or via
hardware. The software procedure below applies to a system running
on a Windows OS. For other OS shutdown procedures, refer to the
related user documentation.
To turn off the system via software:
1
Press Ctrl+Alt+Delete on the attached keyboard or click the Start
on the Windows taskbar.
2
3
Select Shut Down.
Select Shut down from the drop-down menu, then click OK.
To turn off the system via hardware:
If you cannot shut down the server via software, press the power
button for at least four seconds or until the server shuts down. Quickly
pressing the button may put the server in a Suspend mode only.
Download from Www.Somanuals.com. All Manuals Search And Download.
This chapter discusses the precautionary
measures and installation procedures you
need to know to upgrade the system.
Download from Www.Somanuals.com. All Manuals Search And Download.
39
Installation precautions
Before you install any server component, we recommend that you read
the following sections. These sections contain important ESD
precautions along with pre-installation and post-installation
instructions.
ESD precautions
Electrostatic discharge (ESD) can damage the processor, disk drives,
expansion boards, motherboard, memory modules and other server
components. Always observe the following precautions before you
install a server component.
•
Do not remove a component from its protective packaging until
you are ready to install it.
•
•
Do not touch the component pins, leads, or circuitry.
Components with a Printed Circuit Board (PCB) assembly should
always be laid with the assembly-side down.
•
Wear a wrist grounding strap and attach it to a metal part of the
server before handling components. If a wrist strap is not
available, maintain contact with the server throughout any
procedure requiring ESD protection.
•
Keep the work area free of nonconductive materials, such as
ordinary plastic assembly aids and foam packing.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
40
Pre-installation instructions
Perform the steps below before you open the server or before your
remove or replace any component.
Warning! Failure to properly turn off the server before you
start installing components may cause serious damage. Do
not attempt the procedures described in the following
sections unless you are a qualified service technician.
1
2
3
4
5
6
Turn off the system and all the peripherals connected to it.
Unplug the power cord from the power outlet.
Unplug all peripheral cables from the system.
Place the system unit on a flat, stable surface.
Open the system according to the instructions on page 41.
Follow the ESD precautions described in this section when
handling a server component.
Post-installation instructions
Perform the steps below after installing a server component.
1
See to it that all components are installed according to the
described step-by-step instructions.
2
Reinstall all hardware structure or cable that have been previously
removed.
3
4
5
6
Reinstall the top cover.
Reinstall the front bezel.
Reconnect the necessary cables.
Turn on the system.
Download from Www.Somanuals.com. All Manuals Search And Download.
Opening the server
Caution! Before you proceed, make sure that you have turned
off the system and all peripherals connected to it. Read the “Pre-
installation instructions” section on page 40.
You need to open the server before you can install additional
components. The front bezel and top cover are removable to allow
access to the system’s internal components. Refer to the following
sections for instructions.
Removing and installing the front bezel
To remove the front bezel:
Grasp the front bezel at outer edge and pull straight out.
Download from Www.Somanuals.com. All Manuals Search And Download.
43
Removing and installing the top cover
To remove the top cover:
1
2
Perform the pre-installation instructions described on page 39.
Loosen the two captive screws located on the faceplate of the
chassis (A).
3
4
Slide the top cover toward the back of the chassis until the tabs on
the cover disengage with the slots on the chassis.
Lift the top cover away from the server and put it aside for
reinstallation later (B).
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
44
To install the top cover:
1
2
Perform the pre-installation instructions described on page 39.
Place the top cover on the chassis so that the tabs on the cover
align with the slots on the chassis (A).
3
4
Slide the top cover toward the front of the chassis until it is fully
closed.
Tighten the captive screws on the faceplate of the chassis (B).
A
B
Download from Www.Somanuals.com. All Manuals Search And Download.
45
Removing and installing the processor
air baffle
To remove the processor air baffle:
You will need to remove the processor air baffle to perform the
following procedures.
•
•
•
•
•
Removing and installing a heat sink
Removing and installing a processor
Removing and installing the SAS module
Removing and installing the RAID activation key and RAID cache
Removing and installing the RAID BBU
1
2
Perform the pre-installation instructions described on page 39.
Disconnect the 100-pin cable from the mainboard connector on
the front panel I/O board then move cable over the side of the
chassis.
3
Disconnect any cables attached to the device in the 5.25-inch
peripheral bay.
4
5
Insert your fingers into the holes on the top of the baffle.
Pull the baffle up and back to disengage the baffle from the two
sheet-metal tabs on front of the baffle.
6
Lift the baffle from the chassis.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
46
To install the processor air baffle:
1
2
Perform the pre-installation instructions described on page 39.
Insert the front of the processor air baffle (A) under the two metal
tabs at the front of the baffle (B), just below the SAS backplane
board. One tab is located on each side of the chassis.
A
B
B
Download from Www.Somanuals.com. All Manuals Search And Download.
47
3
Lower the rear of the baffle into place (A), making sure the guides
on each side of the air baffle will correctly engage in the left and
right chassis slots (B).
A
A
B
A
B
B
4
5
Push down the air baffle to ensure it is fully seated.
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
48
Configuring hot-pluggable
components
Hot-pluggable components are the components that can be removed
and replaced while the system is powered on. For this server model, it
refers to the following components.
•
•
•
•
Hard disk drive
System fan assembly
Power supply
PCI card with OS hot-plug interface
Download from Www.Somanuals.com. All Manuals Search And Download.
49
Removing and installing a hard disk drive
The system supports eight hot-plug drive carriers. Each carrier holds a
standard 2.5-inch SAS hard drive.
Note: Use only Acer-qualified HDDs. To purchase an HDD, contact
your local Acer representative.
Caution! To ensure proper airflow and server cooling, all drive
or a hard disk carrier cover.
Determining drive status
Each HDD carrier features two status LED indicators to display the hard
drive status. If you are replacing a failed HDD, determine which drive
has failed by checking the drive status LED. For more information on
how to determine the drive status, refer to “Control panel LED
indicators” section on page 20.
To remove an HDD:
1
2
Observe the ESD precautions described on page 39.
Remove the front bezel. Perform the instructions described in “To
remove the front bezel” section on page 41.
3
4
If you are removing a failed HDD, determine which drive has failed
by checking the drive status LEDs.
Press the green HDD carrier latch (A).
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
50
5
Pull the lever and slide the carrier from the chassis (B).
B
A
6
7
Place the HDD carrier on a clean, static-free work surface.
If you are replacing a hard disk, remove the four screws that secure
the hard disk to the HDD carrier, then remove the disk from the
HDD carrier.
8
To install an HDD:
Note: To purchase an HDD carrier, contact your local Acer
representative.
1
Perform steps 1 through 5 of the “To remove an HDD” section on
page 49.
Download from Www.Somanuals.com. All Manuals Search And Download.
51
2
3
Remove the four screws that secure the air baffle to the HDD
carrier (A).
Remove the air baffle from the HDD carrier (B).
4
5
6
Save the air baffle and screws for later use.
Remove the HDD from its protective packaging.
Install a hard disk on the HDD carrier, then secure it with the four
screws (A) that came with the HDD carrier (B).
B
A
7
With the lever still extended, slide the HDD carrier all the way into
the drive bay (A).
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
52
8
Use the lever to push the HDD carrier until it docks into place, then
close the HDD carrier lever (B).
A
B
9
Setup the new hard drive’s RAID configuration.
For related instructions, refer to “RAID configuration utilities” on
page 177.
Removing and installing the system fan
The system has two cooling fan assemblies — two fan modules for each
assembly — located on the front panel and four cooling fans located at
the rear of the chassis.
Cautions:
•
System fan hot-swap operations should be performed only if a
failure occurs in the fan assembly.
•
System cooling is reduced during the fan replacement process. Do
not leave a system fan removed for longer than two minutes.
•
Do not touch the fan blades while they are turning.
Download from Www.Somanuals.com. All Manuals Search And Download.
53
Determining fan status
Each fan or fan assembly has an amber LED to indicate a failed fan
condition. If the amber LED is on, the fan assembly needs to be
replaced. The LED remains off during normal operation.
To remove the front system fan assembly:
1
2
Observe the ESD precautions described on page 39.
Remove the front bezel. Perform the instructions described in “To
remove the front bezel” section on page 41.
3
4
5
Locate the fan assembly you are replacing. If a fan in the assembly
has failed the amber LED will be lit (A).
Press the green button on the front of the fan assembly to release
the handle (B).
Use the handle to pull the fan from the system (C).
To install the front system fan assembly:
Warning! To ensure proper system cooling, the replacement
of a failed system fan module should be completed within
one minute.
1
2
If necessary, remove the old front system fan assembly. See
previous section.
Slide the new fan into the fan bay (A).
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
54
3
Push the handle closed until it clicks into place (B).
To remove a rear system fan:
1
2
Perform the pre-installation instructions described on page 39.
Locate the fan assembly you are replacing. If a fan in the assembly
has failed the amber LED will be lit.
3
Grasp the fan by the finger holes and squeeze together, then lift
the fan upward.
Download from Www.Somanuals.com. All Manuals Search And Download.
55
To install a rear system fan:
Warning! To ensure proper system cooling, the replacement
of a failed system fan module should be completed within
one minute.
1
2
3
If necessary, remove the old rear system fan. See previous section.
Lower the new fan into the fan bay.
Push down on the fan until it clicks into place.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
56
Removing and installing a power supply
The server has two power supply bays on the rear panel that accept
hot-swap redundant power supply modules. The system ships out with
at least one power supply module installed.
Power supply redundancy is available if two power supplies are
installed. A redundant power configuration enables a fully-configured
system to continue running even if one power supply module fails.
WARNING! To reduce the risk of personal injury or damage to
the equipment, the installation of power supply modules
should be referred to individuals who are qualified to service
server systems and are trained to deal with equipment capable
of generating hazardous energy levels.
WARNING! To reduce the risk of personal injury from hot
surfaces, observe the thermal labels on each power supply
module. You can also consider wearing protective gloves.
WARNING! To reduce the risk of personal injury from electric
shock hazards, do not open the power supply modules. There
are no serviceable parts inside the module.
Caution! Electrostatic discharge can damage electronic
components. Make sure that you are properly grounded
before handling a power supply module.
Caution! The system operating voltage range is 110 to 240
VAC. Do not plug the power cord into an incorrect voltage
source.
Determining power supply status
The power supply module has three status LED indicators to display the
power supply status. If the center LED is lit, the power supply needs to
be replaced. For more information on how to determine the power
supply status, refer to “Hot-plug power supply module LED indicators”
section on page 24.
Download from Www.Somanuals.com. All Manuals Search And Download.
57
To remove a power supply:
Caution: Power supply hot-swap operations should be performed
only if a failure occurs in the power supply.
1
2
3
4
5
Observe the ESD precautions described on page 39.
Remove the AC power cord from the power supply.
Press down on the latch to release the power supply handle (A).
Open the handle on the power supply (B).
Pull the power supply from the chassis and set it on a clean, static-
free surface (C).
A
C
B
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
58
To install a power supply:
1
2
If necessary, remove the old power supply. See previous section.
With the handle in the open position, push the power supply in
the bay fully (A).
3
4
Rotate the handle to the closed position (B).
Tighten the thumbscrew to secure the power supply (C).
A
B
5
6
Plug the power cord into the AC receptacle on the power supply.
Verify that the LEDs on the power supply are functioning. Refer to
the “Hot-plug power supply module LED indicators” section on
page 24 for more information.
Download from Www.Somanuals.com. All Manuals Search And Download.
59
Removing and installing a PCI card
Important: Only PCI add-in cards in PCI slots 1 and 2 are
hot-pluggable. If you are installing or removing a PCI card from
PCI slot 3 through 7, see page 82 for more information.
Caution: Expansion slot covers must be installed over all vacant
slots to maintain the electromagnetic emission characteristics of
the server and to ensure proper system cooling.
Determining PCI slot status
The PCI slots 1 and 2 have a LED indicator to display the PCI hot-plug
status. For more information on how to determine the slot status, refer
to “Hot-plug PCI Express slot LED indicators” section on page 25.
To remove a hot-plug PCI card with OS hot-plug interface:
1
2
Perform the pre-installation instructions described on page 39.
If you are using a Microsoft Windows operating system, double-
click the Unplug/Eject icon in the taskbar to open the Unplug or
Eject Hardware menu.
3
4
Select the device to be removed and click Stop.
Make sure that the power LED on the rear of the PCI slot is turned
off before disconnecting any cables attached to the card.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
60
5
6
Open the yellow caution plate (A).
Rotate the slot retention latch on the rear of the card slot upward
(B).
7
Release the vertical edge of the card and pull it away from the
chassis (C).
B
d
ar
dd-in C
PCI A
e
ution Plat
A
a
PCI C
C
8
9
Store the card in an antistatic protective wrapper.
If installing a new PCI card, see “To install a new PCI hot-plug PCI
card” section.
10 Observe the post-installation instructions described on page 40.
To remove a hot-plug PCI card with hardware interface:
1
2
Perform the pre-installation instructions described on page 39.
Press the attention button for this slot.
Download from Www.Somanuals.com. All Manuals Search And Download.
61
Note: Press the attention button again within five seconds to
abort the hot-plug operation.
3
Make sure that the power LED on the rear of the PCI slot is turned
off before disconnecting any cables attached to the card.
4
5
Open the yellow caution plate (A).
Rotate the slot retention latch on the rear of the card slot upward
(B).
6
Release the vertical edge of the card and pull it away from the
chassis (C).
B
d
ar
dd-in C
PCI A
e
ution Plat
A
a
PCI C
C
7
8
Store the card in an antistatic protective wrapper.
If installing a new PCI card, see “To install a new PCI hot-plug PCI
card” section.
9
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
62
To install a new hot-plug PCI card:
1
2
3
4
If your server is operating, use your OS to power down the PCI slot.
Perform the pre-installation instructions described on page 39.
Open the yellow caution plate (A).
Rotate the slot retention latch on the rear of the card slot upward
(B).
5
6
Remove the PCI card from its protective packaging.
Align then insert the card into the selected slot. Make sure that
the card is properly seated (C).
B
d
ar
dd-in C
PCI A
e
A
ution Plat
a
PCI C
C
7
8
9
Rotate the retention latch downward.
Connect any required cable to the card.
When using the hot-plug PCI card with OS hot-plug interface:
•
Wait for the software user interface to appear on your
monitor and then confirm the device to be enabled.
•
Wait for the power LED to turn on.
If using the hot-plug PCI card with hardware interface:
•
Press the attention button for the slot. If you need to abort
the hot-plug operation, press the attention button again
within five seconds.
•
Wait for power LED to turn on.
10 Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
63
Configuring cold-pluggable
components
Cold-pluggable components are the components that require the
system to be powered down before you can remove or replace them.
The cold-pluggable components installed in the server include.
•
•
•
•
•
•
•
•
•
•
•
DVD drive
5.25-inch drive
Processor
Memory board assembly
DIMM module
PCI card
I/O expansion module
ARMC/3 R2 module
SAS module
RAID activation key and RAID cache
RAID BBU
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
64
Removing and installing the DVD drive
To remove the DVD drive:
1
2
Perform the pre-installation instructions described on page 39.
Disconnect the power and SATA cables from the SATA-to-IDE
converter board on the rear of the media device (A).
3
4
Press the blue release latch on the media device carrier (B).
Slide the media device from the front opening in the faceplate of
the system (C).
5
6
Lift the rear right corner of the media device to remove it from the
carrier (D) and (E).
Remove the SATA-to-IDE converter board (F).
Download from Www.Somanuals.com. All Manuals Search And Download.
65
7
Observe the post-installation instructions described on page 40.
To install the DVD drive:
1
2
3
4
Perform the pre-installation instructions described on page 39.
If necessary, remove the old DVD drive. See previous section.
Remove the new drive from its protective packaging.
Attach the SATA-to-IDE converter board to the new media device
(A).
5
Install the media device into the carrier (B).
6
7
Slide the carrier into the front opening in the chassis (C).
Plug the SATA and power cables into the converter board (D).
8
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
66
Installing a 5.25-inch drive
The 5.25-inch drive bay allows you to install a tape drive to provide the
system with additional storage capacity.
To install a 5.25-inch drive:
1
2
3
Perform the pre-installation instructions described on page 39.
Push the tabs on both sides of the carrier filler panel (A).
Hold the tabs in while pulling the carrier filler panel from the bay
(B).
4
5
Remove the screws that attach the slide rails to the filler panel.
Attach the slide rails to the device, then secure it with screws you
removed earlier.
6
Attach the Y-power cable to the rear of the device.
Download from Www.Somanuals.com. All Manuals Search And Download.
67
Slide the 5.25-inch peripheral device into the server until it clicks
7
into place.
8
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
68
Upgrading the processor
The server supports up to four processors, the following models are
supported.
•
•
Quad-core Intel Xeon processors 7300 series
Dual-core Intel Xeon processors 7200 series
Processor configuration guidelines
Observe the following guidelines when replacing or installing a
processor.
•
•
Use only Acer-qualified processors.
The CPU 1 socket must always be populated. If no processor is
installed in this socket, the system will fail to boot.
•
•
Before removing a processor, make sure to back up all important
system files.
When installing a second, third, or fourth processor, make sure it
has same stepping and frequency specifications as the default
processor.
•
•
Handle the processor and the heatsink carefully. Damage to either
may prevent the system from functioning properly.
Caution! Make sure to install a processor thermal blank and a
heat sink to replace the thermal blank. Only power on a system
that has all four CPU sockets populated with heat sinks and/or
thermal blanks.
To install a new processor:
1
2
Warning! The heat sink becomes very hot when the system
is on. NEVER touch the heat sink with any metal or with
your hands.
If necessary, remove the processor air baffle. Perform instructions
described in “To remove the processor air baffle” section on page
45.
Download from Www.Somanuals.com. All Manuals Search And Download.
69
3
Remove the thermal blank.
(1) Loosen the four screws on the thermal blank.
(2) Pull the thermal blank away from the CPU socket.
hermal
T
Blank
(3) Store the thermal blank in a protective bag.
Remove the new processor from its protective packaging.
Install the new processor.
4
5
(1) Pull the CPU socket retainer lever to a fully open position.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
70
(2) Position the processor over the socket, matching the two
triangle markers (A) and lining up the processor pins with the
socket (B).
(3) Press the retainer lever down to lock the processor in place.
6
7
Apply thermal grease.
Apply approximately 0.1 ml of the thermal grease compound to
the top of the processor.
Install the heat sink.
(1) Set the heat sink on the processor, aligning the four screws in
the heat sink with the screw sockets in the chassis.
Download from Www.Somanuals.com. All Manuals Search And Download.
71
(2) Tighten the screws in the order shown, approximately one full
turn at a time until each is evenly tightened. Do not fully
tighten one screw at a time.
3
1
2
4
8
Observe the post-installation instructions described on page 40.
To remove a processor:
Important: Before removing a processor from the mainboard,
make sure to create a backup file of all important data.
1
Warning! The heat sink becomes very hot when the system
is on. NEVER touch the heat sink with any metal or with
your hands.
2
3
If necessary, remove the processor air baffle. Perform instructions
described in “To remove the processor air baffle” section on page
45.
If a heatsink is installed, remove the heat sink.
(1) Loosen the four screws on the heat sink in the order shown.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
72
(2) Pull the heat sink away from the CPU socket.
3
1
2
4
(3) Lay down the heat sink in an upright position—with the
thermal patch facing upward. Do not let the thermal patch
touch the work surface.
(4) Use an alcohol pad to wipe off the thermal grease from both
the heat sink and processor.
4
Remove the processor.
Warning! The processor becomes very hot when the system
is on. Allow it to cool off first before handling.
(1) Pull the CPU socket retainer lever to the fully open, upright
position.
Download from Www.Somanuals.com. All Manuals Search And Download.
73
(2) Pull out the processor from the socket.
(3) Store it in an antistatic bag.
5
6
7
If you are not installing a new processor, reinstall the processor
thermal blank to maintain proper airflow within the chassis.
If you going to install a new processor, perform instructions
described in “To install a new processor” section.
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
74
Removing and installing a memory board
assembly
The server supports up to four memory boards. At least one memory
board and two FBDIMMs must be installed for the server to function.
Each memory board supports eight DIMM slots and a DIMM fault LED
for each FBDIMM that is used to report DIMM failures and error
conditions.
The supported memory board configurations are as follows.
•
•
•
side of the system.
Two memory boards, installed in memory board slots A and B, the
two boards at the right side of the system.
All four memory boards, slots A, B, C, and D.
Important: Refer to the memory board installation order table
on page 166 when installing and removing memory boards.
Caution! Damage to the system occurs if power is not removed
from the system prior to removal or installation of memory
boards.
To remove the memory board assembly:
Note: If you remove a memory board from the server, you must
replace it with a replacement memory board.
1
Perform the pre-installation instructions described on page 39.
Download from Www.Somanuals.com. All Manuals Search And Download.
75
2
3
Lift the latches on the memory board to disengage the memory
board from the mainboard (A).
Lift the memory board by the latches (B).
B
A
4
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
76
To install the memory board assembly:
1
2
3
Perform the pre-installation instructions described on page 39.
Locate an empty memory board slot.
Add or replace memory DIMMs as needed. For instructions, see
“Installing and removing DIMM modules” section.
4
Lift the memory board latches to the fully open position.
5
Insert the memory board until latches are securely locked.
6
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
77
Installing and removing DIMM modules
The server’s memory board supports eight DIMM slots. Each slot
supports 1 GB, 2 GB, and 4 GB DDR2-667 (PC2-5300) FBDIMM modules.
The server’s maximum memory capacity is 128 GB.
DIMM module configuration guidelines
Observe the following guidelines when replacing or installing DIMM
modules to the memory boards.
•
The system supports up to four memory boards. At least one
memory board and two DIMMs must be installed for the server to
function. Each memory board must have a minimum of two
DIMMs installed.
•
•
•
DIMMs must be installed in pairs. For example, DIMM slots 1 and 2,
DIMM slots 3 and 4, DIMM slots 5 and 6, DIMM slots 7 and 8
DIMMs in the same memory board must be identical in size, speed,
and vendor.
The system does not support mixed-sized DIMMs or DIMMs from
different vendors within the same memory board.
Warning! Functionality issues may be encountered if mixed
memory types are installed on the memory board.
•
•
The system does not support combination of single-rank with dual-
rank memory.
Use only DDR2 FBDIMMs. Other type of DIMMs will not fit into the
damage and/or the socket or the DIMM.
•
•
Hold DIMMs only by the edges. Do not touch the components or
gold edge connectors.
Install DIMMs with gold-plated edge connectors only.
Important: Follow the DIMM module “FBDIMM module
population order” section on page 167 when installing and
removing DIMMs.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
78
DIMM population guidelines
The following rules apply when adding DIMMs to the memory boards.
•
DIMMs must be populated beginning with memory board A,
DIMM slots A1 and A2.
•
All DIMM slots must be populated with either a DIMM or a DIMM
thermal blank.
Important: DIMM thermal blanks must be installed to empty
DIMM slots to ensure proper system thermal performance.
d
y Boar
emor
M
ocket 8
ocket 7
ocket 6
ocket 5
ocket 4
ocket 3
ocket 2
ocket 1
S
S
S
S
S
S
S
S
FBDIMM
•
FBDIMMs should be identical in terms of timing, technology, and
size.
Note: For additional memory configuration, see “Appendix B:
Memory configuration” section on page 163.
Download from Www.Somanuals.com. All Manuals Search And Download.
79
To install DIMMs in the memory board:
Caution! Use extreme care when installing a DIMM. Applying too
much pressure can damage the connector. DIMMs are keyed and
can be inserted in only one way.
Note: DIMM slots on the memory board must be installed only in
certain configurations. Numbers next to DIMM slots correspond to
installation sequence. DIMMs may be installed in pairs.
1
2
Perform the pre-installation instructions described on page 39.
Remove the memory board assembly. Perform the instructions
described in “To install the memory board assembly” section on
page 76.
3
Remove the DIMM cover from the memory board.
(1) Press down on the hooks on the underside of the memory
board to disengage them (A).
(2) Lift the DIMM cover from the memory board (B).
B
A
4
Install DIMMs in the correct order. See “DIMM population
guidelines” section on page 78.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
80
5
6
7
Open the clips on the DIMM slot(s) (A).
Align (B) then insert the DIMM into the socket (C).
Push down on the top edge of the DIMM. Make sure the holding
clips lock the DIMM in place (D).
8
Visually check that each latch is fully closed and correctly engaged
with each DIMM slot (E).
Note: The DIMM slot is slotted to ensure proper installation. If
you insert a DIMM but it does not fit easily into the socket, you
may have inserted it incorrectly. Reverse the orientation of the
DIMM and insert it again.
E
C
E
B
D
A
9
Install the DIMM cover to the memory board.
(1) Lower the DIMM cover over the DIMM slots.
(2) Line up the hooks in the cover with the notches on the bottom
edge of the memory board.
(3) Press the DIMM cover down until it clicks into place.
10 Install the memory board assembly. For instructions, see “To install
the memory board assembly” section on page 76.
11 Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
81
To remove DIMMs on the memory board:
Before you can install a new DIMM in a socket, remove first any
previously installed DIMM from that socket.
Important: Before removing any DIMM from the memory board,
make sure to create a backup file of all important data.
Caution! Use extreme care when removing DIMMs. Too much
pressure can damage the connector. Apply only enough pressure
on the plastic levers to release the DIMM.
1
2
Perform steps 1 to 3 described in the “To install DIMMs in the
memory board” section.
Press the holding clips on both sides of the DIMM slot outward to
release the DIMM.
3
4
Gently pull the DIMM upward to remove it from the socket.
Install the memory board assembly. For instructions, see “To install
the memory board assembly” section on page 76.
5
Observe the post-installation instructions described on page 40.
To reconfigure the system memory:
The system automatically detects the amount of memory installed. Run
the BIOS setup to view the new value for total system memory and
make a note of it.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
82
Removing and installing a non-hot-plug PCI card
PCI cards installed in slots 1 and 2 are hot-pluggable. If you are adding
or removing a card from one of these slots, you can do so without
powering down the server. For information, refer to page 59.
To remove a non-hot-plug PCI card:
Caution! Damage to the system occurs if power is not removed
from the system prior to removal or installation of non-hot-plug
boards.
1
2
3
Perform the pre-installation instructions described on page 39.
Disconnect any cables attached to the PCI card.
Perform steps 5 through 10 described in the “To remove a hot-plug
PCI card with OS hot-plug interface” section on page 59.
To install a non-hot-plug PCI card:
1
2
Perform the pre-installation instructions described on page 39.
Perform steps 2 to 8 described in the “To install a new hot-plug PCI
card” section on page 62.
Download from Www.Somanuals.com. All Manuals Search And Download.
83
Configuring server management
components
Altos R920 system provides an upgrade path to advanced server
management capabilities through installation of the following
components.
•
•
I/O expansion module
ARMC/3 R2 module
Installing and removing the I/O expansion module
The optional I/O expansion module is a vertical riser with a dedicated
management Ethernet port, and additional dual-gigabit Ethernet
ports.
To install the I/O expansion module:
1
2
3
4
5
Perform the pre-installation instructions described on page 39.
Rotate the retention latch on the rear of the card slot upward (A).
Pull up the slot cover (B).
Remove the board from its protective packaging.
Align the board in the empty slot (C).
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
84
6
Insert the module into the I/O expansion module slot on the
mainboard. Make sure that the card is properly seated (D).
B
A
C
D
7
8
Rotate the retention latch downward.
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
85
To remove the I/O expansion module:
1
2
Perform the pre-installation instructions described on page 39.
Rotate the retention latch on the rear of the I/O expansion module
slot upward (A).
3
Pull the board away from the chassis (B).
B
A
4
5
Store the board in an antistatic bag.
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
86
Installing and removing the ARMC/3 R2 module
The optional ARMC/3 R2 module provides server management
firmware and functionality for the system.
To install the ARMC/3 R2 module:
1
2
Perform the pre-installation instructions described on page 39.
Remove the I/O expansion module. Perform instructions described
in “To remove the I/O expansion module” section on page 85.
3
Set the I/O expansion module on a static controlled surface with
components facing up.
4
5
6
Record the MAC address on the ARMC/3 R2 module.
Peel off the backing from the EMI gasket (A).
Adhere the gasket to the I/O expansion module where the ARMC/3
R2 NIC module will contact the I/O expansion module (B).
Net
w
ork I/O Expansion M
odule
B
A
Download from Www.Somanuals.com. All Manuals Search And Download.
87
7
Install the ARMC/3 R2 NIC module.
(1) Attach the ARMC/3 R2 NIC module to the I/O expansion
module.
(2) Secure the ARMC/3 R2 NIC module to the I/O expansion
module with the two screws provided.
Net
w
ork I/O Expansion M
odule
ARMC/3
NIC
8
Install the ARMC/3 R2 module.
(1) Insert the standoff into the hole in the ARMC/3 R2 module
(A). The standoff installs on the bottom side of the module.
(2) Attach the module to the module connector on the I/O
expansion module and snap the standoff into the matching
hole on the I/O module (B).
Net
w
ork I/O Expansion M
odule
ARMC/3
NIC
A
ARMC/3
A
B
9
Install the I/O expansion module. Perform instructions described
on “To install the I/O expansion module” section.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
88
10 Observe the post-installation instructions described on page 40.
To remove the ARMC/3 R2 module:
1
2
Perform the pre-installation instructions described on page 39.
Remove the I/O expansion module. Perform instructions described
in “To remove the I/O expansion module” section on page 85.
3
4
Set the I/O expansion module on a static controlled surface with
components facing up.
Remove the ARMC/3 R2 NIC module.
(1) Remove the three screws on the ARMC/3 R2 NIC module.
(2) Pull the ARMC/3 R2 NIC module to remove it.
Remove the ARMC/3 R2 module.
5
6
(1) Pull up the ARMC/3 R2 module to remove it from the
connector.
(1) Remove the three standoffs from the mainboard, then keep
the standoffs for later installation.
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
89
Configuring the hardware RAID
components
Altos R920 system supports SAS hardware RAID through installation of
of a SAS module. With the addition of the following components to
the SAS module enhanced RAID capability is enabled.
•
•
•
RAID activation key
RAID cache
RAID BBU (battery backup unit)
Installing and removing the SAS module
The SAS module works with the SAS backplane board to support eight
SAS hard drives. The SAS module supports RAID levels 0, 1, 1a, and 10
without any additional components.
To install the SAS module:
1
2
Perform the pre-installation instructions described on page 39.
Remove the processor air baffle. Perform instructions described in
“To remove the processor air baffle” section on page 45.
3
4
Remove the SAS module from its protective packaging.
If you want to install a RAID activation key, RAID cache, RAID BBU
on the adapter, refer to succeeding sections for instructions.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
90
5
Align then insert the SAS module in the SAS module slot on the
mainboard. Make sure that the edge of the card is properly seated
(A).
6
Press down on the card until the metal bracket on the card is flush
with the chassis (B) and locks into place (C).
A
C
B
Download from Www.Somanuals.com. All Manuals Search And Download.
91
7
8
Attach the SAS expander cables to the SAS connector A (A) and
the SAS connector B (B) on the adapter.
Attach the SES cable to the SES connector on the SAS module (C).
C
B
A
9
Observe the post-installation instructions described on page 40.
To remove the SAS module:
1
2
Perform the pre-installation instructions described on page 39.
Remove the processor air baffle. Perform instructions described in
“To remove the processor air baffle” section on page 45.
Download from Www.Somanuals.com. All Manuals Search And Download.
3 System upgrade
92
3
Disconnect any cables attached to the SAS module.
4
While pushing back on the slot divider latch, pull the SAS module
away from the chassis.
5
6
Store the card in an antistatic bag.
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
93
Installing and removing the RAID activation key
and RAID cache
The optional RAID activation key and RAID cache enables enhanced
RAID functionality on the SAS module. The RAID cache serves as
to the drives. The RAID cache must be a 512 MB DDR2-667 DIMM.
To install the RAID activation key and RAID cache:
1
2
Perform the pre-installation instructions described on page 39.
Remove the processor air baffle. Perform instructions described in
“To remove the processor air baffle” section on page 45.
3
Remove the SAS module. Perform instructions described in “To
install the SAS module” section on page 89.
4
5
Remove the RAID activation key from its protective packaging.
Align then insert the activation key into the RAID activation key
connector on the SAS module (A).
6
7
8
Open the clips on the RAID cache slot on the SAS module (B).
Align then insert the RAID cache into the slot (C).
Push down on the top edge of the RAID cache until the holding
clips snap in place (D).
B
RAID
Key
C
A
D
9
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
94
To remove the RAID activation key and RAID cache:
1
2
Perform the pre-installation instructions described on page 39.
Remove the processor air baffle. Perform instructions described in
“To remove the processor air baffle” section on page 45.
3
4
Remove the SAS module. Perform instructions described in
“To remove the SAS module” section on page 89.
Insert the tip of a small flat-bladed screwdriver under the plastic
tab on the retainer holding the activation key to the mainboard.
5
6
Gently push down to detach the activation key (A).
Press the holding clips on both sides of the slot outward to release
the RAID cache (B).
7
8
Gently pull the RAID cache upward to remove it from the slot (C).
Close the clips (D).
B
RAID
Key
C
A
D
9
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
95
Installing and removing the RAID BBU
If power to the SAS controller on the SAS module drops below
specifications, the optional RAID BBU maintains the contents of the
DIMM by keeping the cache in self-refresh mode until power is
restored. After power is restored, the data is safely written to the
drives, maintaining the integrity of the disk array.
To install the RAID BBU:
1
2
Perform the pre-installation instructions described on page 39.
Remove the processor air baffle. Perform instructions described in
“To remove the processor air baffle” section on page 45.
3
4
5
Remove the SAS module. Perform instructions described in “To
remove the SAS module” section on page 89.
Align then insert the RAID BBU into the battery connector on the
SAS module.
Secure the RAID BBU with the three screws provided.
Battery
Connector
RAID Battery
Backup Unit
Mounting
Holes
SAS Module
6
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
96
To remove the RAID BBU:
1
2
Perform the pre-installation instructions described on page 39.
Remove the processor air baffle. Perform instructions described in
“To remove the processor air baffle” section on page 45.
3
Remove the SAS module. Perform instructions described in “To
remove the SAS module” section on page 89.
4
5
6
Remove the three screws on the RAID BBU.
Remove the RAID BBU from the SAS module.
Observe the post-installation instructions described on page 40.
Download from Www.Somanuals.com. All Manuals Search And Download.
This chapter gives information about the
system BIOS and discusses how to configure
the system by changing the settings of the
BIOS parameters.
Download from Www.Somanuals.com. All Manuals Search And Download.
99
BIOS overview
The Aptio Setup Utility is a hardware configuration program built into
the system's Basic Input/Output System (BIOS). Since most systems are
already properly configured and optimized, there is no need to run this
utility. You will need to run this utility under the following conditions.
•
•
•
When changing the system configuration settings
When redefining the communication ports to prevent any conflicts
When changing the password or making other changes to the
security settings
•
When a configuration error is detected by the system and you are
prompted ("Run Setup" message) to make changes to the BIOS
setup
Note: If you repeatedly receive Run Setup messages, the battery
may be bad. In this case, the system cannot retain configuration
values in CMOS. Ask a qualified technician for assistance.
BIOS setup loads the configuration values in a battery-backed
nonvolatile memory called CMOS RAM. This memory area is not part of
the system RAM which allows configuration data to be retained when
power is turned off.
Before you run BIOS setup, make sure that you have saved all open
files. The system reboots immediately after you close the Setup.
Note: Aptio Setup Utility will be simply referred to as “BIOS
setup”, “Setup”, “System BIOS” or “Setup Utility” in this guide.
The screenshots used in this guide display default system values.
These values may not be the same as those found in the system.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
100
Entering BIOS setup
Power on the server to start the system POST process. During bootup,
press F2 to enter the BIOS setup screen.
Note: You must press F2 while the system is booting. This key does
not work during any other time.
BIOS setup menus
There are several tabs on the setup screen corresponding to the eight
primary BIOS menus.
•
•
•
•
•
•
•
•
Main
Advanced
Security
Server Management
Boot Options
Boot Manager
Error Manager
Exit
In the descriptive table following each of the screen illustrations,
settings in boldface are the default and suggested parameter settings.
Download from Www.Somanuals.com. All Manuals Search And Download.
101
BIOS setup keyboard commands
Use the following commands to navigate through the Setup Utility.
•
Left and Right arrow keys - Move between selections on the
menu bar.
•
•
Up and Down arrow keys - Move the cursor to select an item.
+ and - keys - Press the keys to scroll through drop down list values
in ascending or descending order without displaying the full list.
Note: Grayed-out items have fixed settings and are not
user-configurable.
•
Esc key - If you press this key:
•
•
•
While a drop-down list is displayed, the primary menu
displays.
While a sub-menu is displayed, the submenu is closed and the
primary menu displays.
On one of the primary menu screens, the Exit menu displays.
•
Enter key - Display a submenu screen as well as drop-down lists.
Note: When a parameter is preceeded by a [>], it means that a
submenu screen is available.
•
•
F9 key - Load the default configuration.
F10 key - Save changes made and close the BIOS setup.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
102
Main menu
The Main menu displays basic and important information about the
system. These information are necessary for troubleshooting and may
be required when asking for technical support. These entries are for
your reference only and are not user-configurable.
Parameter
Description
Option
Logged in as
<Administrator/
User>
Displays the security account used to enter the Setup
Utility.
Platform ID
Displays the system name.
System BIOS
Version
Version of the BIOS.
Build Date
Date BIOS was created.
Download from Www.Somanuals.com. All Manuals Search And Download.
103
Parameter
Description
Option
Processor
Type
Specification of the processor currently installed in the
server.
Processor clock speed in GHz or MHz.
Core Frequency
Number of processors currently installed in the server.
Count
Memory
Size
Total size of system memory detected during POST.
Quiet Boot
When enabled, the BIOS splash screen
displays during startup.
Enabled
Disabled
When disabled, the diagnostic screen
displays during startup.
POST Error Pause
When enabled, the system will enter the
Error Manager for critical POST errors.
When disabled, the system will continue
to boot bypassing the Error Manager for
critical POST errors.
Enabled
Disabled
System Date
System Time
Sets the date following the month-day-year format.
Valid values for weekday, month, day, and year are:
Month: 1 to 12
Day: 1 to 31
Year: 1998 to 2099
Sets the time following the hour-minute-second
format. Valid values for hour, minute, and second are:
Hour: 00 to 23
Minute: 00 to 59
Second: 00 to 59
Download from Www.Somanuals.com. All Manuals Search And Download.
105
Processor Configuration
Parameter
Description
Option
Core Frequency
Frequency at which the processors currently run in.
Frequency of the processor front side bus.
System Bus
Frequency
Enhanced Intel
SpeedStep Tech
When enabled, this feature allows the OS Enabled
to reduce power consumption.
Disabled
When disabled, the system operates at
maximum processor speed.
Intel (R)
Virtualization
Technology
Enables or disables the system to run
multiple operating systems and
applications in different partition.
Enabled
Disabled
Execute Disable
Bit
Enables or disables the execute disable bit Enabled
to prevent certain classes of malicious
buffer overflow attacks.
Disabled
Hardware
Prefetcher
Enables or disables the processor
Hardware Prefetch feature.
Enabled
Disabled
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
106
Parameter
Description
Option
Adjacent Cache
Line Prefetch
When enabled, cache lines are fetched in
pairs (even line + odd line).
Enabled
Disabled
When disabled, only the current cache line
required is fetched.
Simulated MSI
Support
Enables or disables the simulation of
Message Signal Interrupt (MSI) support.
Enabled
Disabled
Note: This feature can be enabled in the
case where there is no OS support for MSI.
Processor
Retest
When an error message associated with
the processor occurs during POST, you can
enable this parameter to eliminate the
error message.
Enabled
Disabled
Processor <n>
Information
Displays information about the system processor, such as
family or generation, frequency supported, cache size,
stepping number, and processor ID register value.
Press Enter to access the Processor # Information
submenu.
Download from Www.Somanuals.com. All Manuals Search And Download.
107
Memory Configuration
Parameter
Description
Total Memory
Total amount of onboard memory in MB or GB. The
memory size is automatically detected by BIOS during the
POST. If you install additional memory, the system
automatically adjusts this parameter to display the new
memory size.
Effective
Memory
Amount of memory available to the operating system in
MB or GB.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
108
Parameter
Description
Current
Configuration
Displays either one of the following memory
configuration:
•
Maximum performance mode - System memory is
configured for optimal performance and efficiency. No
RAS features are enabled.
•
•
Single channel mode - System memory is functioning in
a reduced efficiency fail-safe mode.
Memory mirroring mode - System memory is
configured for maximum reliability in the form of
memory mirroring.
•
Dual-DIMM sparing mode - System memory is
configured for optimal performance and efficiency.
Sparing is also enabled.
Current
Memory Speed
Displays the speed the memory is currently running at 533
MT/s (266 MHz) or 667 MT/s (333 MHz).
Memory RAS
and
Performance
Configuration
Customize several memory configuration options, such as
whether to use memory mirroring or memory sparing.
Press Enter to access the Memory RAS and Performance
Configuration submenu.
Memory Riser
Board <n>
Displays details about the memory boards and associated
FBDIMMs installed.
Configuration
Press Enter to access the Memory Riser Board <n>
Configuration submenu.
Download from Www.Somanuals.com. All Manuals Search And Download.
109
Memory RAS and Performance Configuration
Parameter
Description
Option
Memory
Mirroring
Possible
Indicates if system memory is configured Yes/No
for memory mirroring.
Memory
Indicates if system memory is configured Yes/No
Sparing Possible for memory sparing.
Select Memory
RAS
Configuration
Provides options for configuring
Memory RAS. The possible options for
this menu item are:
RAS Disabled
Sparing
Mirroring
•
RAS Disabled - Normal mode of
operation.
•
Sparing - Improves reliability by
reserving memory for use as a
replacement in the event of DIMM
failure.
•
Mirroring - Optimizes reliability by
using half of physical memory as a
backup.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
110
Parameter
Description
Option
Snoop Filter
The Snoop Filter component monitors
and controls the data transactions
between memory and the processor.
Enabled
Disabled
FSB High
Bandwidth
Optimization
Enables or disables optimize front side
bus for higher bandwidth when 1333
MHz FSB processor(s) is installed.
Enabled
Disabled
Note: Some applications will benefit
with this option enabled. Configure
based on performance result.
Download from Www.Somanuals.com. All Manuals Search And Download.
111
Mass Storage Controller Configuration
Parameter
Description
Option
SAS Option
ROM
Enables or disables the onboard SAS
controller option ROM.
Enabled
Disabled
SATA Mode
When set to IDE, system supports up to 4
SATA ports with Parallel ATA emulation.
IDE
AHCI
When set to AHCI, system supports all
SATA ports using the Advanced Host
Controller interface.
SW RAID
When set to SW RAID, system supports
configuration of SATA ports for RAID via
RAID configuration software.
SATA Port 0, 1,
2, 3, 4, 5
Indicates information for the device connected to the
SATA connector.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
112
Serial Port Configuration
Parameter
Description
Option
Serial A Enable Enables or disables the onboard serial A
port.
Enabled
Disabled
Address
Set the base I/O address for serial A port.
3F8
2F8
2E8
3E8
IRQ
Set the interrupt request line for the serial
A port.
4
3
Serial B Enable Enables or disables the onboard serial B
port.
Enabled
Disabled
Address
Set the base I/O address for serial B port.
2F8
3F8
2E8
3E8
Download from Www.Somanuals.com. All Manuals Search And Download.
113
Parameter
Description
Option
IRQ
Set the interrupt request line for the serial
B port.
3
4
USB Configuration
Parameter
Description
Indicates the number of USB devices.
Option
Detected USB
Devices
USB Controller
When enabled, all onboard USB controllers Enabled
will be turned on and accessible by the OS.
Disabled
When disabled, all onboard USB
controllers will be turned off and
inaccessible by the OS.
Legacy USB
Support
Enables or disables support for legacy USB Enabled
devices.
Disabled
Auto
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
114
Parameter
Description
Option
Port 60/64
Emulation
Enables or disables the I/O port 60/64h
emulation support.
Enabled
Disabled
This parameter is enabled for complete
USB keyboard legacy support for non-USB
aware OS.
Device Reset
Timeout
Select the number of seconds POST waits
for the USB mass storage device after the
start unit command.
10 Seconds
20 Seconds
30 Seconds
40 Seconds
Storage
Emulation
RMM
When set to Auto, USB mass storage
devices with less than 530 MB will be
emulated as a floppy drive.
Auto
Floppy
Forced FDD
Hard Disk
CD-ROM
When set to Forced FDD, HDD formatted
drive will be emulated as FDD (e.g. Zip
drive).
USB 2.0
Controller
Enables or disables onboard USB ports to
support USB 2.0 mode.
Enabled
Disabled
Download from Www.Somanuals.com. All Manuals Search And Download.
115
PCI Configuration
Parameter
Description
Option
Memory
Mapped I/O
Start Address
Select the start of the reserved memory
region for PCI memory mapped I/O space
that ends at 4 GB.
2.00 GB
2.25 GB
2.50 GB
1.50 GB
1.75 GB
Note: Depending on the system
configuration, this option may impact the
amount of system memory detected by an
OS without Physical Address Extension
(PAE) support.
Memory
Mapped I/O
Above 4 GB
Enables or disables memory mapped I/O
of 64-bit PCI devices to 4 GB or greater
address space.
Enabled
Disabled
Onboard Video
Enables or disables the onboard VGA
controller.
Enabled
Disabled
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
116
Parameter
Description
Option
Dual Monitor
Video
Select a graphic controller as a primary
boot device.
Enabled
Disabled
Note: This parameter will be disabled
when the Onboard Video is set to
Disabled.
Slot <n> ROM
Controls execution of the add-in adapter
option ROM during POST.
Enabled
Disabled
Note: If set to disabled, the adapter may
not be used to boot the system.
Download from Www.Somanuals.com. All Manuals Search And Download.
117
LAN Configuration
Parameter
Description
Option
Intel (R) I/OAT Enables or disables the onboard LAN’s
I/O Acceleration Technology. The I/O AT
accelerates TCP/IP processing for onboard
NICs, delivers data movement efficiencies
across the entire server platform and
minimizes system overhead.
Enabled
Disabled
Onboard NIC1 Enables or disables the load of embedded
Enabled
or NIC2 ROM
option ROM for onboard network controller.
Disabled
Note: If disabled, NIC1 and NIC2 cannot be
used to boot the system.
Onboard NIC
iSCSI ROM
Enables or disables the load of embedded
Internet SCSI option ROM for the onboard
network controller.
Enabled
Disabled
Onboard NIC1 Indicates the media access control of the system’s LAN
or NIC2 MAC
Address
controller.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
118
Parameter
Description
Option
I/O Riser
Board NIC
ROM
Load the embedded option ROM for the I/O
expansion module network controllers.
Enabled
Disabled
Note: If disabled, the I/O expansion module
(NIC1 and NIC2) cannot be used to boot or
wake the system.
I/O Riser
Enables or disables the I/O expansion module
Enabled
Board NIC1 or network controller.
NIC2
Disabled
I/O Riser
Indicates the media access control of the I/O expansion
Board NIC1 or module’s LAN controller.
NIC2 MAC
Address
Download from Www.Somanuals.com. All Manuals Search And Download.
119
System Acoustic and Performance Configuration
Parameter
Description
Option
Throttling
Mode
Closed loop allows the system to achieve
higher performance by monitoring system
temps and adjusting bandwith.
Closed Loop
Open Loop
Open loop does not rely on a thermal
sensor on the board and sets up a static
level which equates to a fixed bandwidth.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
120
Security menu
The Security menu allows you to safeguard and protect the system
from unauthorized use by setting up access passwords.
Parameter
Description
Option
Administrator
Password
Status
Indicates the status of the administrator password.
User Password
Status
Indicates the status of the user password.
Set
Administrator password prevents unauthorized access to
the Setup Utility.
Administrator
Password
Press Enter to change the Administrator password.
Set User
Password
User password is used to control entry access to the Setup
Utility. User password is available only when an
Administrator password is set.
Press Enter to change the User password.
Download from Www.Somanuals.com. All Manuals Search And Download.
121
Parameter
Description
Option
Front Panel
Lockout
When enabled, the front panel power
and reset buttons will be locked. The
power and reset operation must be
controlled via system management
interface.
Enabled
Disabled
TPM State
Shows the current state of the Trusted
Platform Module (TPM) device.
Enabled &
Activated
Enabled &
Deactivated
Disabled &
Activated
Disabled &
Deactivated
TPM
Administrative
Control
When set to no operation, there are no
changes made to this parameter.
Turn On
Turn Off
When set to turn on, TPM is enabled and
activated.
Clear
Ownership
When set to turn off, TPM is disabled and
deactivated.
No Operation
When set to clear ownership, TPM
ownership authentication is removed
and returned to factory default state.
Note: By default, the BIOS setting will
return to the no operation state on every
boot cycle.
Setting a system password
1
Use the up/down keys to highlight a password parameter (Set
Administrator Password or Set User Password) then press Enter.
2
Type a password then press Enter.
The password may consist of up to seven alphanumeric characters
(A-Z, a-z, 0-9).
3
Retype the password to verify the first entry then press Enter
again.
After setting the password, the system automatically sets the
chosen password parameter to Installed.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
122
Changing a system password
1
Use the up/down keys to highlight either change password
parameters (Set Administrator Password or Set User Password)
then press Enter.
2
3
4
Type the original password then press Enter.
Type a new password then press Enter.
Retype the password to verify the first entry then press Enter
again.
Removing an administrator password
Note: Removing the administrator password also removes the
user password.
1
Use the up/down keys to highlight the Set Administrator Password
parameter then press Enter.
2
3
Enter the current password then press Enter.
Press Enter twice without entering anything in the new and
confirm password fields.
After doing this, the system automatically sets the User password
parameter to Not Installed.
Download from Www.Somanuals.com. All Manuals Search And Download.
123
Server Management menu
The Server Management submenu lets you specify the appropriate
settings for the system’s event handling function.
Parameter
Description
Option
Resume on AC Defines the mode of operation if a power
Stay Off
Last state
Reset
Power Loss
loss occurs.
When set to Stay Off, the system remains off
after power shutdown.
When set to Last state, the system returns to
the state it was prior to the AC power loss.
When set to Reset, the system will turn on
after power is restored.
Clear System
Event Log
Deletes all entries in the System Event Log.
Enabled
Disabled
Reset on Fatal When enabled, system will trigger a reset in Enabled
Error
response to fatal errors.
Disabled
When disabled, system will trigger a non-
masked interrupt in response to fatal errors.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
124
Parameter
Description
Option
FRB-2 Enable
When enabled, the BMC (Baseboard
Management Controller) will reset the
system if BIOS does not complete the POST
before the FRB-2 (Fault Resilient Boot) timer
expires.
Enabled
Disabled
OS Boot
Watchdog
Timer
Enables or disables the BIOS timer. It helps
to determine if the OS has loaded
successfully or followed the OS boot
watchdog timer policy.
Enabled
Disabled
The BIOS timer can only be shut off using
the management software after the OS
loads.
OS Boot
Watchdog
Timer Policy
When set to Power Off, the system powers
off if the watchdog timer expires.
Power Off
Reset
When set to Reset, the system performs a
reset if the watchdog timer expires.
Note: The OS Boot Watchdog Timer must
be enabled at the same time.
OS Boot
Timeout value BIOS will use to configure the 10 minutes
Watchdog
Timer Timeout
watchdog timer.
15 minutes
20 minutes
5 minutes
Console
Displays console redirection-related settings.
Redirection
Press Enter to access the Console Redirection submenu.
System
Information
Displays basic system ID information, as well as firmware
versions.
Press Enter to access the System Information submenu.
Intel (R)
Displays information about the I/O expansion module.
Remote
Management
Module
Press Enter to access the System Information submenu.
Note: This option is displayed if the I/O expansion module is
installed.
Information
Download from Www.Somanuals.com. All Manuals Search And Download.
125
Console Redirection
Parameter
Description
Option
Console
Redirection
Define the serial port used for server
management tasks.
Disabled
Serial Port A
Serial Port B
Flow Control*
Baud Rate*
Set hardware flow control.
None
RTS/CTS
Set the serial port transmission speed.
115.2 K
9.6 K
19.2 K
38.4 K
57.6 K
Terminal Type* Set character formatting used for console
redirection.
VT100
VT100+
VT-UTF8
PC-ANSI
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
126
Parameter
Description
Option
Legacy OS
Redirection*
Enables or disables the legacy OS
redirection (i.e. DOS) on the serial port. If it
is enabled the associated serial port is
hidden from the legacy OS.
Enabled
Disabled
* These fields are not shown on the above screenshot.
Download from Www.Somanuals.com. All Manuals Search And Download.
129
Boot Options menu
The Boot Options menu allows you to set the network device priority
during system bootup. It also displays information about the installed
storage devices.
Parameter
Description
Option
xxxxx
Boot Timeout
Sets the automatic boot time-out value.
Note: A value of 65535 will disable the
timeout completely.
Boot Option
#<n>
Set system boot order by selecting the boot option for this
position.
CDROM Order
Specifies the boot device priority sequence for available
CD drives.
Network Device Specifies the boot device priority sequence for available
Order
network devices.
Boot Option
Retry
This will continually retry non-EFI based
boot options without waiting for user
input.
Enabled
Disabled
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
130
Boot Manager menu
The Boot Manager menu lets you set the device priority during system
bootup. The server will attempt to boot from the first device on the
list. If the first device is not available, it will continue down the list until
it reaches an available device. Select a boot option, then press Enter.
Download from Www.Somanuals.com. All Manuals Search And Download.
131
Error Manager menu
The Error Manager menu lets you view the system POST errors
detected by the system.
Parameter
Error Code
Severity
Description
Attribute
Displays the POST error beep codes.
Major severity requires user intervention
but does not stop system boot.
Major
Minor
Fatal
Minor severity do not require user
intervention or stop the booting of the
system.
Fatal severity requires user intervention
and prohibits the system boot.
Instance
Displays the instance value. The instance value identifies
the component in error.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
132
Exit menu
The Exit menu displays the various options to quit from the BIOS setup.
Highlight any of the exit options then press Enter.
Parameter
Description
Save Changes and Exit
Discard Changes and Exit
Save Changes
Saves changes made and close the BIOS setup.
Discards changes made and close the BIOS setup.
Saves changes made in the BIOS setup.
Discards all changes made in the BIOS setup.
Discard Changes
Load Default Values
Loads the default settings for all BIOS setup
parameters. Setup defaults are quite demanding
in terms of resources consumption. If you are
using low-speed memory chips or other kinds of
low-performance components and you choose to
load these settings, the system might not
function properly.
Download from Www.Somanuals.com. All Manuals Search And Download.
133
Parameter
Description
Save as User Default
Values
Saves current values to be restored later.
Load User Default Values
Restores previously saved user default values.
Download from Www.Somanuals.com. All Manuals Search And Download.
4 System BIOS
134
Upgrading the BIOS
The upgrade utility allows you to upgrade the BIOS in the flash
memory. To prepare to upgrade the BIOS, you need to record the
current BIOS settings and download the BIOS image file to a temporary
folder on your hard drive or a USB flash memory device.
To record the current BIOS settings:
1
2
Run BIOS setup. See “Entering BIOS setup” on page 100.
Write down the current settings in the Setup Utility.
To download the BIOS image file:
Download the image file to a temporary folder on your hard drive or a
USB flash memory device.
Note: Review the instructions and release notes that are provided
in the Readme file distributed with the BIOS image file before
attempting a BIOS upgrade. The release notes contain critical
information regarding jumper settings, specific fixes, or other
information to complete the upgrade.
To upgrade the BIOS:
Follow the instructions in the Readme file that came with the BIOS
upgrade. When the update completes, remove the bootable media
from which you performed the upgrade.
Note: Do not power down the system during the BIOS update
process. The system will reset automatically when the BIOS update
process is completed. You may encounter a CMOS checksum error
or other problem after reboot. It this happens, shut down the
system and boot it again. CMOS checksum errors require that you
enter Setup, check your settings, save your settings, and exit
Setup.
Download from Www.Somanuals.com. All Manuals Search And Download.
This chapter provides possible solutions for specific
problems. If you cannot correct the problem,
contact your local Acer representative or
authorized dealer for assistance.
Download from Www.Somanuals.com. All Manuals Search And Download.
137
Troubleshooting
This chapter helps you identify and solve problems that might occur
while you are using the system.
For any issue, first ensure that you are using the latest firmware and
files. In addition to the server firmware and files, make sure to update
any drivers used for components you have installed in your system,
such as video drivers, network drivers and SAS drivers.
If you are unable to resolve your server problems on your own, contact
your dealer or local Acer representative for assistance.
Resetting the system
Before going through in-depth troubleshooting, attempt first to
perform reset the system using one of the methods below.
To do this
Press
Soft boot reset to clear the system memory and reload the
operating system.
Ctrl+Alt+Del
Clear system memory, restart POST, and reload the OS.
Reset button
Power off/on
Cold boot reset. Turn the system power off and then on.
This clears system memory, restarts POST, reloads the
operating system and halts power to all peripherals.
Problems following initial system installation
Problems that occur at initial system startup are usually caused by an
incorrect installation or configuration. Hardware failure is a less
frequent cause. If the problem you are experiencing is with a specific
software application, see "There is problem with the application
software" on page 144.
Download from Www.Somanuals.com. All Manuals Search And Download.
5 System troubleshooting
138
First steps checklist
•
AC power available at the wall outlet?
•
Are the power supplies plugged in? Check the power cable(s) on
the back of the chassis and at the AC source.
•
•
•
Are all cables correctly connected and secured?
Is the processor fully seated in the socket on the mainboard?
Are all standoffs in the proper location and not touching any
components, causing a potential short?
•
Are all expansion boards fully seated in their slots on the
mainboard?
•
•
Are all jumper settings on the mainboard correct?
Are all jumper and switch settings on expansion boards and
peripheral devices correct? If applicable, ensure that there are no
conflicts - for example, two expansion boards sharing the same
interrupt.
•
•
Are all peripheral devices installed correctly?
If the system has a hard disk drive, is it properly formatted or
configured?
•
•
•
Are all device drivers properly installed?
Are the configuration settings made in BIOS setup correct?
Is the operating system properly loaded? Refer to the operating
system documentation.
•
•
•
Did you press the system power button on the front panel to turn
the server on (power indicator should be lit)?
Is the system power cord properly connected to the system and
plugged into an outlet for 110-240 V?
Are all integrated components from the tested components lists?
Check the tested memory, and chassis lists, as well as the supported
hardware and operating system list.
Download from Www.Somanuals.com. All Manuals Search And Download.
139
Hardware diagnostic testing
This section provides a more detailed approach to identifying a
hardware problem and locating its source.
Caution! Before disconnecting any peripheral cables from the
system, turn off the system and any external peripheral devices.
Failure to do so can cause permanent damage to the system and/
or the peripheral devices.
1
Turn off the system and all external peripheral devices. Disconnect
each of device from the system, except for the keyboard and the
video monitor.
2
3
Make sure the system power cord is plugged into a properly
grounded AC outlet.
Make sure your video display monitor and keyboard are correctly
connected to the system. Turn on the video monitor. Set its
brightness and contrast controls to at least two thirds of their
maximum ranges (see the documentation supplied with your video
display monitor).
4
If the operating system normally loads from the hard disk drive,
make sure there is no disc in the optical drive.
5
6
If the power indicator does light, attempt to boot from a disc.
Turn on the system. If the power indicator does not light, see
“Power indicator does not light” on page 140.
Verifying proper operation of key system lights
As POST determines the system configuration, it tests for the presence
of each mass storage device installed in the system. As each device is
activity indicator lights briefly? If not, see “HDD activity indicator does
not light.” on page 141.
Confirming loading of the OS
Once the system boots up, the operating system prompt appears on
the screen. The prompt varies according to the operating system. If the
operating system prompt does not appear, see "No Characters Appear
on Screen" on page 145.
Download from Www.Somanuals.com. All Manuals Search And Download.
5 System troubleshooting
140
Specific problems and corrective actions
The following contains specific problems that may arise during the use
of your server. Possible solutions are listed for each problem.
Power indicator does not light.
Do the following:
•
•
•
Make sure the power button on the front panel is turned on.
Make sure the power cable is connected correctly.
Make sure that the wall outlet has power. Test it by plugging
another device.
•
Remove all non-hot-plug expansion cards and see if the system
boots. If successful, add the cards back in one at a time with a
reboot between each addition.
•
•
Make sure the memory board and memory modules comply with
the system requirements.
Make sure the memory modules have been populated according
to the system requirements.
•
•
•
•
Remove and reseat the memory board.
Remove and reseat the memory modules.
Make sure the processor complies with the system requirements.
Make sure the processor is populated according to the system
requirements.
•
•
Remove and reseat the processor.
Make sure the chassis standoffs are installed only below mounting
holes. Misplaced standoffs may have contact to the pins on the
bottom of the mainboard and cause a short.
Server powers on but turns off often with fault light.
Do the following:
•
•
Make sure the memory boards are properly seated.
Make sure the processor is properly seated.
Download from Www.Somanuals.com. All Manuals Search And Download.
141
Server boot does not complete POST.
Do the following:
•
•
Make sure the processor is properly seated.
Check the BIOS release notes to ensure the BIOS installed on the
platform supports the stepping and the family of processors
currently installed.
•
Make sure the memory boards are populated according to system
requirements.
Server does not recognize all of the processors installed.
Make sure the processor is properly seated.
•
HDD activity indicator does not light.
Do the following:
•
•
Make sure the drive is not disabled in the system BIOS.
Make sure the drive’s power and data cables are connected
correctly.
•
•
Make sure the drive is compatible.
Make sure you have not exceeded the power budget for the
server.
•
If using a RAID configuration with SAS drives, make sure the server
RAID adapter is installed correctly.
If you have installed one or more hard drives in the system, do the
following:
•
Make sure the power and signal cables are connected correctly.
ODD (Optical disk drive) activity indicator does not light.
Do the following:
•
•
Make sure the power and signal cables are properly installed.
Check that relevant switches and jumpers on the drive are set
correctly.
Download from Www.Somanuals.com. All Manuals Search And Download.
5 System troubleshooting
142
•
•
Check that drive is properly configured.
Check that onboard IDE controller is enabled in the BIOS Setup
Utility.
ODD tray cannot be ejected.
•
Insert the tip of a paperclip into the small hole on the ODD drive.
Slowly pull the tray out from the drive until the tray is fully
extended then remove the disc.
ODD drive cannot read a disc.
Do the following:
•
•
•
•
Make sure you are using the correct type of disc.
Make sure the disc is properly seated in the drive.
Make sure the disc is unscratched.
Make sure all cables are connected to the ODD.
Hard drives are not recognized.
•
•
Make sure the drive is not disabled in the system BIOS.
Make sure the drive is connected correctly and the power cable is
plugged to the power supply.
•
•
Make sure the drive is compatible.
Make sure that you have not exceeded the power budget for the
server.
Bootable CD drive is not detected.
•
Make sure the Boot settings in the system BIOS is configured to
allow the CD drive to be the first bootable device.
Download from Www.Somanuals.com. All Manuals Search And Download.
143
New memory modules installed are not detected.
Do the following:
•
•
•
Make sure the memory modules are properly seated on the
memory board’s DIMM slots.
Make sure the memory modules comply with the system
requirements.
Make sure the memory modules have been populated according
to the system requirements.
External device connected to a USB connector does not work.
Do the following:
•
•
Reduce the number of external devices connected to a USB hub.
Refer to the documentation that came with the device.
Cannot connect to a server.
•
Make sure the network cable is securely attached to the correct
connector at the system rear panel.
•
•
•
Try a different network cable.
Make sure you are using the correct and the current drivers.
Make sure the driver is loaded and the protocols are bound.
Problems with the network
Network status indicator does not light.
Do the following:
•
Check the cabling and network equipment to make sure that all
cables are properly connected.
•
•
Reinstall the network drivers.
Try another port or hub on the switch.
Download from Www.Somanuals.com. All Manuals Search And Download.
5 System troubleshooting
144
Diagnostics pass but the connection fails.
•
•
Make sure the network cable is securely attached.
Make sure you specify the correct frame type in the NET.CFG file.
The controller stopped working when an adapter was installed.
•
•
•
Make sure the cable is connected to the port from the onboard
network controller.
Make sure the other adapter supports shared interrupts and your
OS supports shared interrupts.
Try reseating the adapter.
The adapter stopped working without apparent cause.
•
•
Try reseating the adapter first, then try a different slot if necessary.
The network files driver may be corrupt or deleted. Delete and
reinstall the drivers.
•
Run the diagnostics.
Network activity indicator does not light.
Do the following:
•
•
Make sure the correct network drivers are loaded on the system.
Network might be idle. Try accessing the server.
Server hangs when the drivers are loaded.
Change the PCI interrupt settings.
•
There is problem with the application software.
Do the following:
•
Verify that the software is properly configured for the system.
Refer to the software installation and operation documentation
for instructions on setting up and using the software.
Download from Www.Somanuals.com. All Manuals Search And Download.
145
•
Try a different version of the software to see if the problem is with
the copy you are using.
•
•
Make sure all cables are properly connected.
If other software runs correctly on the system, contact your vendor
about the defective software.
No characters appear on the screen.
Check the following:
•
Is the keyboard functioning? Test it by turning the “Num Lock”
function on and off to make sure the Num Lock light is
functioning.
•
•
Is the video monitor plugged in and turned on? If you are using a
switch box, is it switched to the correct system?
Are the brightness and contrast controls on the video monitor
properly adjusted?
•
•
Is the video monitor signal cable properly installed?
Does this video monitor work correctly if plugged into a different
system?
•
•
Is the onboard video controller enabled in the BIOS Setup Utility?
Remove all expansion cards and see if the system boots. If
successful, add the cards back in one at a time with a reboot
between each addition.
•
•
Make sure the memory modules comply with the system
requirements.
Make sure the memory modules have been populated according
to the system requirements.
•
•
•
•
Remove and reseat the memory boards.
Remove and reseat the memory modules.
Make sure the processor complies with the system requirements.
Make sure the processor is populated according to the system
requirements.
If you are using a video controller board, do the following:
1
Verify that the video works using the onboard video controller.
Download from Www.Somanuals.com. All Manuals Search And Download.
5 System troubleshooting
146
2
Verify that the video controller board is fully seated in the
mainboard connector.
3
4
Reboot the system for changes to take effect.
If there are still no characters on the screen after you reboot the
system and POST emits a beep code, write down the beep code
you hear. This information is useful for your service representative.
5
If you do not receive a beep code and characters do not appear,
the video display monitor or video controller may have failed.
Contact your service representative or authorized dealer for help.
Characters are distorted or incorrect.
Check the following:
•
Are the brightness and contrast controls properly adjusted on the
video monitor? Refer to the documentation that came with the
video monitor.
•
•
Are the video monitor’s signal and power cables properly
connected.
Is the video monitor working correctly when plugged into a
different system?
System cooling fan do not rotate properly.
If the system cooling fan is not operating properly, it is an indication of
possible system component failure.
Check the following:
•
Is the power indicator lit? If not, see “Power indicator does not
light.” on page 140 .
•
•
•
Is the hot-swap fan module LED lit?
Are any other control panel LEDs lit?
Have any of the fan motors stopped? Use the server management
subsystem to check the fan status.
•
•
Have your fans speeded up in response to an overheating
situation?
Have your fans speeded up in response to a fan that has failed?
Download from Www.Somanuals.com. All Manuals Search And Download.
147
•
•
•
•
Is the fan’s power connector properly connected to the
mainboard?
Is the front panel board cable connected to both the mainboard’s
front panel board connector?
Are the power supply cables properly connected to the
mainboard?
Are there any shorted wires caused by pinched cables or have
power connector plugs been forced into power connector sockets
the wrong way?
Download from Www.Somanuals.com. All Manuals Search And Download.
5 System troubleshooting
148
Download from Www.Somanuals.com. All Manuals Search And Download.
This appendix shows you how to set up the
Altos R920 system in a rack mount configuration.
Download from Www.Somanuals.com. All Manuals Search And Download.
151
Rack installation information
Important! Observe the electrostatic discharge (ESD) precautions
indicated on page 39 when perfoming the following procedures.
Do not attempt the procedures described in the following sections
unless you are a qualified technician.
Rack installation precautions
Follow the rack manufacturer's safety and installation instructions for
proper rack installation.
The following additional rack safety installation measures should be
considered:
•
Anchor the equipment rack
The equipment rack must be anchored to an unmovable suitable
support to prevent the rack from falling over when one or more
systems are fully extended out of the rack assembly. You must also
consider the weight of any other devices installed in the rack
assembly. The equipment rack must be installed according to the
manufacturer's instructions.
•
•
Main AC power disconnect
You are responsible for installing an AC power disconnect for the
entire rack unit. This main disconnect must be readily accessible,
and it must be labeled as controlling power to the entire unit, not
just to the system(s).
Earth ground the rack installation
To avoid the potential for an electrical shock hazard, the rack
assembly itself must be suitably earth grounded, according to your
local regional electrical codes. This typically will require the rack to
have its own separate earth ground. We recommend you consult
your local approved electrician.
Download from Www.Somanuals.com. All Manuals Search And Download.
152
•
Appendix A: Rack mount configuration
Elevated operating ambient temperature
The maximum operating temperature of the system is 35 °C (95°F).
Careful consideration should be given to installing the system in
an environment compatible with the 35 °C (95°F) maximum
ambient temperature.
•
Reduced airflow
The amount of airflow required for the safe operation of the
equipment should not be compromised when installing the system
in a rack.
•
•
Mechanical loading
Exercise care when mounting the system in a rack to avoid any
accidents.
Circuit overloading
Appropriate consideration should be given when connecting the
supply circuit to the system to avoid any circuit overload. The
system name plate rating should be used when addressing
concerns about circuit overload.
Download from Www.Somanuals.com. All Manuals Search And Download.
153
Rack mount configuration
The Altos R920 server system should be mounted into a rack cabinet. A
rack rail and CMA (cable management arm) kit is available for
installing system to a rack cabinet.
The figure below shows the Altos R920 system in a rack-mount
position.
Download from Www.Somanuals.com. All Manuals Search And Download.
154
Appendix A: Rack mount configuration
Vertical mounting hole pattern
The four vertical rails of the system rack contain mounting holes
arranged in a manner shown in the figure below:
The system occupies 4U in the rack. Count the U positions and hole
numbers from the bottom up.
The distance from the center of two holes with closer spacing to the
center of the next pair is equivalent to 1U.
Note: The unit of measurement used in this guide is "U"
(1U = 1.75 inches or 44.45 mm). The total sum of the heights of all
components in the rack measured in "U" cannot exceed the
height of the rack. For more information, refer to the
documentation that came with the system rack.
When installing components, you must start your measurement from
the center of the two holes with closer spacing. Otherwise, the screw
holes on the component may not match those on the rack.
Download from Www.Somanuals.com. All Manuals Search And Download.
155
Installing the system into the rack
Caution! To minimize the chances of injuries, make sure that two
or more people help in installing the server.
To install the system into a four-post rack:
1
Remove the inner rails from the mounting rails.
(1) Extend the inner rail from the mounting rail until the rail
release latch clicks.
(2) Depress the release latch (A) and slip the inner rail out (B).
Download from Www.Somanuals.com. All Manuals Search And Download.
156
Appendix A: Rack mount configuration
(3) Do the same thing to the other mounting rail.
Caution! To avoid personal injury, care should be taken when
pressing the inner rail release latches and sliding the component
into the rack.
2
Attach the inner rails to both sides of the server.
Please use screws that came with the rack-mount kit when
attaching the inner rails to both sides of the server. If your system
already has screws attached, please remove them.
Note: Using screws other than those supplied in this rack-mount
kit to attach the rails will void the warranty, Acer cannot be held
responsible for any damage for incorrect installation.
(1) Align the screw holes of the inner rail to the server screws (A).
(2) Slide the rails to the left until the rails lock into place with an
audible click (B).
Download from Www.Somanuals.com. All Manuals Search And Download.
157
3
Install the mounting rails to the rack posts.
(1) Determine the vertical position in the rack. Refer to “Vertical
mounting hole pattern” on page 154 for more information.
(2) Align and insert the mounting rail into the rack posts’
mounting holes (A).
(3) Make certain the proper mounting holes on the rack post are
selected.
(4) Use two metal screws to secure the front and rear mounting
rail to the rack (B).
(5) Do the same thing to the other mounting rail.
Download from Www.Somanuals.com. All Manuals Search And Download.
158
Appendix A: Rack mount configuration
(6) Fully extend the mounting rails on the rack.
Download from Www.Somanuals.com. All Manuals Search And Download.
159
4
Install the server into the rack.
Caution! To avoid personal injury, care should be taken when
pressing the inner rail release latches and sliding the component
into the rack.
(1) Carefully align the inner rails attached to the server with the
fully extended mounting rails on the rack.
(2) Press the release latch on both sides of the server (A).
(3) Insert the inner rails into the mounting rails, then push the
server into the rack until you hear a click sound (B).
(4) Secure the server to the rack using the two front panel
thumbscrews (C).
Download from Www.Somanuals.com. All Manuals Search And Download.
160
5
Appendix A: Rack mount configuration
Attach the CMA (cable management arm) to the rear of the server.
The CMA allows you to tie-wrap all cables to and from the system.
As you slide the system in and out of the rack, the CMA collapses
and extends, keeping the cables untangled and attached to the
system.
(1) Insert the smaller CMA extension into the rear of the left inner
rail (A1).
(2) Insert the larger CMA extension into the rear of left mounting
rail (A2).
(3) Insert the CMA extension connector into the rear of the right
mounting rail (B1).
(4) Insert the CMA arm connector into the blue plastic cutout on
the CMA extension connector (B2).
(5) Attach the cable clips into the appropriate mounting holes in
the CMA (C).
Download from Www.Somanuals.com. All Manuals Search And Download.
161
(6) Connect the power, peripheral and networking cables into
their appropriate ports.
Refer to “Connecting peripherals” on page 32 for detailed
instructions.
(7) Route all cables through the cable clips.
Download from Www.Somanuals.com. All Manuals Search And Download.
162
Appendix A: Rack mount configuration
Download from Www.Somanuals.com. All Manuals Search And Download.
This chapter provides details on how to configure
the system memory boards. Recommended memory
board and FBDIMM installation order and FBDIMM
population order tables are also included.
Download from Www.Somanuals.com. All Manuals Search And Download.
165
Introduction
The system’s memory architecture supports up to four memory boards
organized by branches and channels. The MCH (memory controller
hub) on the north bridge has two branches with branch 0 going to
channels 0 and 1 or memory board A and B, and branch 1 to channels 2
and 3 or memory board C and D.
In dual-channel mode, FBDIMMs on adjacent channels work in lockstep
to provide the same cache line data and a combined ECC. In the single-
channel mode only channel 0 is active. The BIOS dynamically configures
the memory controller in accordance with the available FBDIMM
population and the selected RAS (reliability, availability, serviceability
(RAS) mode operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: Memory configuration
166
The memory boards connect to the mainboard through the memory
board slots A, B, C, and D (Each slot support the x16 PCI Express
mechanical slot, refer to “Mainboard” on page 12 for the location of
the memory board slots.). Each memory board is equipped with eight
DIMM slots that supports 1 GB, 2 GB, or 4 GB DDR2-667 MHz (PC-5300)
FBDIMM modules. The memory board includes a DIMM fault LED that
is used to report DIMM failures and error conditions.
Refer to “Memory configuration” on page 171 for details on the
available system memory configuration.
Memory board installation order
The table below lists the suggested memory board installation order.
Installation order
Memory sparing Memory mirroring
configuration configuration
Memory
board
slot
Normal
configuration
A
B
C
D
1
2
3
4
Set 1
Note: Requires
installation of four
memory boards with
equal memory capacity.
Set 2
Note: Requires
installation of two or four
sets of memory boards,
paired as sets of two. Each
memory board in a set
must have same amount
of memory board
installed.
Download from Www.Somanuals.com. All Manuals Search And Download.
167
FBDIMM module population order
Single and dual channel population
The tables below list the suggested FBDIMM module population for
normal configuration.
Population with one memory board
Total
DIMM slot Memory board A Memory board B Memory board C Memory board D
memory
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
2 x 1 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
2 GB
4 GB
6 GB
8 GB
4 GB
8 GB
12 GB
16 GB
8 GB
16 GB
24 GB
32 GB
Population with two memory boards
Total
memory
DIMM slot Memory board A Memory board B Memory board C Memory board D
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
2 x 1 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
2 x 1 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 GB
8 GB
12 GB
16 GB
8 GB
16 GB
24 GB
32 GB
16 GB
32 GB
48 GB
64 GB
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: Memory configuration
168
Population with four memory boards
Total
memory
DIMM slot Memory board A Memory board B Memory board C Memory board D
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
2 x 1 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
2 x 1 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
2 x 1 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
2 x 1 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
8 GB
16 GB
24 GB
32 GB
16 GB
32 GB
48 GB
64 GB
32 GB
64 GB
96 GB
128 GB
Download from Www.Somanuals.com. All Manuals Search And Download.
169
Memory sparing population
The tables below list the suggested FBDIMM module population for
memory sparing configuration.
Population with two memory boards
Total memory
DIMM Memory board Memory board Memory board Memory board
Physical
memory
Detected
by OS
slot*
A
B
C
D
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
2 x 1 GB
2 x 1 GB
4 GB
3 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
8 GB
7 GB
12 GB
16 GB
8 GB
11 GB
15 GB
6 GB
16 GB
24 GB
32 GB
16 GB
32 GB
48 GB
64 GB
14 GB
22 GB
30 GB
12 GB
28 GB
44 GB
60 GB
* DIMM slot 1 in memory boards A and B is configured to sparing mode.
Population with four memory boards
Total memory
DIMM Memory board Memory board Memory board Memory board
Physical
memory
Detected
by OS
slot*
A
B
C
D
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
2 x 1 GB
2 x 1 GB
2 x 1 GB
2 x 1 GB
8 GB
6 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
16 GB
24 GB
32 GB
16 GB
32 GB
48 GB
64 GB
32 GB
64 GB
96 GB
128 GB
14 GB
22 GB
30 GB
12 GB
28 GB
44 GB
60 GB
24 GB
56 GB
88 GB
120 GB
* DIMM slot 1 in memory boards A, B, C, and D is configured to sparing mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: Memory configuration
170
Memory mirroring population
The table below list the suggested FBDIMM module population for
memory mirroring configuration.
Population with four memory boards
Total memory
DIMM Memory board Memory board Memory board Memory board
slot
A
B
C
D
Physical
memory
Detected
by OS
(Mirror)
(Mirror)
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
1 to 2
1 to 4
1 to 6
1 to 8
2 x 1 GB
2 x 1 GB
2 x 1 GB
2 x 1 GB
8 GB
4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
4 x 1 GB
6 x 1 GB
8 x 1 GB
2 x 2 GB
4 x 2 GB
6 x 2 GB
8 x 2 GB
2 x 4 GB
4 x 4 GB
6 x 4 GB
8 x 4 GB
16 GB
24 GB
32 GB
16 GB
32 GB
48 GB
64 GB
32 GB
64 GB
96 GB
128 GB
8 GB
12 GB
16 GB
8 GB
16 GB
24 GB
32 GB
16 GB
32 GB
48 GB
64 GB
Download from Www.Somanuals.com. All Manuals Search And Download.
171
Memory configuration
The BIOS configures the system memory into the best possible
configuration after comparing the current FBDIMM population with
the desired memory configuration selected by the user in System BIOS.
Possible configurations are:
•
•
•
•
Dual-channel mode (Maximum performance mode)
Single-channel mode
Memory sparing mode
Memory mirroring mode
Only one memory mode can be selected at a time and the BIOS
defaults to maximum performance mode. Support is also included for
memory sparing, where a portion of each memory board is reserved
for failover.
Dual-channel mode
Dual-channel mode (maximum performance mode) is the default
memory configuration and provides the highest system performance
and increased FBD bandwidth. This requires each lock-stepped pair of
FBDIMMs on a branch to be identical. A lock-stepped FBDIMM pair is
defined as the FBDIMMs installed in identically numbered FBDIMM
sockets on both memory boards (channels) on a given memory branch.
No RAS (reliability, availability, and serviceability) features are enabled
in this configuration.
To configure memory to maximum performance mode:
1
2
3
Run BIOS setup. See “Entering BIOS setup” on page 100.
Use the up and down arrow keys to select the Advanced menu.
Use the up and down arrow keys to select Memory
Configuration, then press Enter. The Memory Configuration
menu appears.
4
Use the up and down arrow keys to select Memory RAS and
Performance Configuration, then press Enter. The Memory RAS
and Performance Configuration menu appears.
5
6
Set the Select Memory RAS Configuration to RAS Disabled.
Press F10 to save changes and exit.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: Memory configuration
172
7
Press Y to confirm. The server reboots to activate the changes.
Single-channel mode
Single-channel mode is a failsafe mode when the installed memory
configuration is incompatible with dual-channel operation. In this
mode, only Branch 0, Channel 0 is operational with all other FBDIMMs
disabled automatically.
To configure memory to single-channel mode:
1
2
3
Run BIOS setup. See “Entering BIOS setup” on page 100.
Use the up and down arrow keys to select the Advanced menu.
Use the up and down arrow keys to select Memory
Configuration, then press Enter. The Memory Configuration
menu appears.
4
Use the up and down arrow keys to select Memory RAS and
Performance Configuration, then press Enter. The Memory RAS
and Performance Configuration menu appears.
5
6
7
Set the Select Memory RAS Configuration to RAS Disabled.
Press F10 to save changes and exit.
Press Y to confirm. The server reboots to activate the changes.
Download from Www.Somanuals.com. All Manuals Search And Download.
173
Memory sparing mode
Sparing is only supported in a lock-stepped (dual-channel)
configuration. Memory sparing is the use of a lock-stepped FBDIMM
rank on a memory branch to provide a backup in case any other lock-
stepped FBDIMM rank on the same branch exceeds a user-selectable
Memory ECC Correctable Error threshold in a fixed time period. This
failure prediction mechanism allows the system to automatically:
•
Copy the contents of a failing FBDIMM rank to a backup or spare
FBDIMM rank
•
Disable the failing FBDIMM rank
These actions are completed before the FBDIMM rank begins to
generate more serious memory ECC uncorrectable errors that would
bring down the system by corrupting memory.
Spare memory configurations
Spared memory configurations do not provide redundant copies of
memory. In addition, the system cannot continue to operate when an
ECC Uncorrectable Error / Multi-Bit Error (UE/MBE) occurs. The purpose
of memory sparing is to provide runtime failure prediction for FBDIMM
ranks exceeding a specified frequency of ECC Correctable Error events
in a given time period.
The underlying assumption is that FBDIMMs generating increasing
numbers of ECC Correctable Errors are eventually prone to ECC
Uncorrectable Errors. These FBDIMMs should be removed from service
prior to causing a system crash.
Once a FBDIMM rank exceeds the specified frequency of ECC
Correctable Errors the contents of the failing FBDIMM rank are copied
to the spare (reserved) FBDIMM rank. Hardware then isolates and
removes the failing FBDIMM rank from the set of active FBDIMM ranks.
These actions prevent future memory errors and maintain system
integrity.
Note: The memory sparing feature requires that the spare
FBDIMM rank be at least the size of the largest primary FBDIMM
rank in use. When sparing is enabled, the BIOS selects the spare
rank automatically during POST. No manual configuration of this
feature is required beyond turning on the feature in BIOS Setup.
With sparing enabled, the total effective memory size is reduced
by the size of the spare FBDIMM rank(s).
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: Memory configuration
174
Dual-ranked memory sparing
When a dual-ranked FBDIMM is used as spare, the BIOS can
independently select a physical rank on that FBDIMM as the spare unit
and utilize the other physical rank as a normal unit. This selective
sparing ensures maximization of available memory while still providing
RAS.
Note: Populating differently ranked FBDIMMs for sparing is not a
good practice and may yield unpredictable results.
To configure memory to memory sparing mode:
1
2
3
Run BIOS setup. See “Entering BIOS setup” on page 100.
Use the up and down arrow keys to select the Advanced menu.
Use the up and down arrow keys to select Memory
Configuration, then press Enter. The Memory Configuration
menu appears.
4
Use the up and down arrow keys to select Memory RAS and
Performance Configuration, then press Enter. The Memory RAS
and Performance Configuration menu appears.
5
6
Set the Select Memory RAS Configuration to Sparing.
Return to the Memory Configuration menu option.
•
Make sure Current Configuration indicates Dual-DIMM
Sparing Mode. If the option indicates Current Memory
Configuration, you may need to install more memory to
meet the requirements of the selected configuration.
•
Make sure that Memory Sparing Possible indicates Yes.
7
8
Press F10 to save changes and exit.
Press Y to confirm. The server reboots to activate the changes.
Download from Www.Somanuals.com. All Manuals Search And Download.
175
Memory mirroring mode
Memory mirroring is a high availability mode providing a redundant
image of the system memory. Two identical images of memory data are
maintained, providing maximum redundancy. Mirroring is achieved
across Branch 0 and Branch 1 such that one of these branches is the
primary image and the other the secondary. The memory controller
alternates between both branches for read transactions. Write
transactions are issued to both branches under normal circumstances.
Due to the available system memory being divided into a primary
image and a copy of the image, the effective system memory is
reduced by one-half. For example, if the system is operating in memory
mirroring mode and the total size of the FBDIMMs is 2 GB, the effective
size of the memory is 1 GB because half of the FBDIMMs are the
secondary images.
For memory mirroring to work, memory boards must be installed in
pairs and all DIMMs with the same slot number must match. For e.g.
Memory board A DIMM slot 1 must be the same as memory board B
DIMM slot 1. DIMMS installed must be the same number of ranks,
timing, and size.
The BIOS provides a Setup option to enable memory mirroring. When
memory mirroring is enabled, the BIOS attempts to configure the
memory system accordingly. If the FBDIMM population is not suitable
for mirroring, the BIOS disables mirroring. It then reverts to the default
non-RAS mode with maximum interleave or to the single channel
mode based on the system memory configuration. BIOS Setup then
displays the selected memory configuration on the next boot.
To configure memory to memory mirroring mode:
1
2
3
Run BIOS setup. See “Entering BIOS setup” on page 100.
Use the up and down arrow keys to select the Advanced menu.
Use the up and down arrow keys to select Memory
Configuration, then press Enter. The Memory Configuration
menu appears.
4
Use the up and down arrow keys to select Memory RAS and
Performance Configuration, then press Enter. The Memory RAS
and Performance Configuration menu appears.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B: Memory configuration
176
5
6
Set the Select Memory RAS Configuration to Mirroring.
Return to the Memory Configuration menu option.
•
Make sure Current Configuration indicates Memory
Mirroring Mode. If the option indicates Current Memory
Configuration, you may need to install more memory to
meet the requirements of the selected configuration.
•
Make sure that Memory Mirroring Possible indicates Yes.
7
8
Press F10 to save changes and exit.
Press Y to confirm. The server reboots to activate the changes.
Download from Www.Somanuals.com. All Manuals Search And Download.
This appendix gives an overview of the RAID
configuration utilities supported by your server.
Download from Www.Somanuals.com. All Manuals Search And Download.
179
Overview
The system may be equipped with a SAS or SAS RAID configuration
utility (depending on your system configuration). You can use these
utilities for configuring the internal hard disks.
Caution: Creating a RAID volume erases all data previously saved
in the hard drives. Make sure that you back up important files
before starting a RAID configuration process.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: SAS and SAS RAID configuration utilities
180
SAS configuration utility
This section briefly shows how to create mirror with LSI 1078
integrated SAS.
Starting the SAS configuration utility
To start the SAS Configuration Utility, press CTRL+C when you see the
SAS BIOS during POST.
Loading the factory default settings
1
In the SAS Configuration Utility, press Alt+N to enter the Global
Properties.
2
3
4
5
6
7
Select Restore Defaults and press Enter.
Press Esc, then select Save changes then exit this menu.
Select SAS1078 and press Enter.
Select Advanced Adapter Properties and press Enter.
Select Restore Defaults and press Enter.
Press Esc twice then select Save changes then exit this menu.
Creating a RAID1 volume with a hot spare disk
1
In the LSI Configuration Utility, please select SAS1078 and press
Enter.
2
3
4
5
Select RAID Properties and press Enter.
Select Create IM Volume and press Enter.
Move the cursor to the RAID Disk column.
Press the Space bar and D to change the setting form No to Yes.
The Drive Status will be marked as Primary.
6
7
Move the cursor to another disk.
Press the Space bar to change the setting from No to Yes. The
Drive Status will be marked as Secondary.
8
9
Move the cursor to the Hot Spr column and select another disk.
Press Space bar to change the setting from No to Yes. The Drive
Status will be marked as Hot Spare.
10 Press C and select Save changes then exit this menu.
Download from Www.Somanuals.com. All Manuals Search And Download.
181
Initializing the RAID volume
You can skip this procedure if you selected to create a new IM array
(or pressed D) while performing the creating a RAID 1 volume with
a hot spare disk section. After you create a new IM array, no
synchronization will be performed. You can exit the SAS configuration
utility and proceed to install the OS.
Exiting the SAS configuration utility
In the SAS configuration utility, press Esc twice and select Exit the
Configuration Utility.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: SAS and SAS RAID configuration utilities
182
SAS RAID configuration utility
This section briefly shows how to launch the SAS RAID configuration
utility, load the factory default setting, and create a RAID volume using
the SAS RAID configuration utility.
Starting the SAS hardware RAID configuration utility
To start SAS RAID Configuration Utility, press CTRL+G when you see
the RAID BIOS during POST. After POST finished, the Adapter Selection
page will show on the screen. Click Start to launch the configuration
menu.
Loading the factory default settings
1
2
3
In the Configuration menu, select Adapter Properties. The
current adapter settings appear.
Change the setting of Set Factory Defaults from No to Yes, then
click Submit.
Press <Ctrl+Alt+Del> to reboot the server.
Creating and initialing a RAID volume
1
2
3
4
5
Launch the Configuration menu.
Select Configuration Wizard.
Select Add Configuration (default) and click Next.
Select Custom Configuration (default) and click Next.
Select the drives that you want to add into the array with the
<Ctrl> key.
6
7
After you select the drives, click Accept Array then Next.
Select the RAID level you want to use, create the logical volume by
specifying the size at Select Size and click Accept to create the
logical volume.
8
9
After you create the logical volumes on all of the RAID volume,
click Accept and Yes to save the configuration.
Click Yes to initialize the new logical drives. The logical drives will
be listed.
10 Click Home to go back to the configuration menu.
Download from Www.Somanuals.com. All Manuals Search And Download.
183
11 Now you can reboot the system and install the Operating System.
Select Exit and click Yes.
12 Press <Ctrl+Alt+Del> to reboot the system.
Assigning a hot spare disk
1
2
3
4
Launch the Configuration menu.
Select a free disk marked as Ready and listed under Physical Drives.
Select Make Hotspare and click Go.
Click Home to return to the Configuration menu. The disk will be
marked as Hotspare in pink and listed under Physical Drives.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C: SAS and SAS RAID configuration utilities
184
Download from Www.Somanuals.com. All Manuals Search And Download.
185
memory board 74
Index
5.25-inch drive
installing 66
cold-pluggable components 63
configuring memory
Numerics
maximum performance mode 171
memory mirroring mode 175
single-channel mode 172
A
ARMC/3 R2
specifications
ARMC/3 R2 module
installing 86
removing 88
5
D
B
DIMM module
BIOS menus
Advanced
LAN Configuration 117
Mass Storage Controller
Configuration 111
Memory configuration 107
PCI Configuration 115
Processor configuration 105
Serial Port Configuration 112
System Acoustic and
F
Performance
Configuration 119
front panel
USB Configuration 113
front system fan assembly
Boot Manager 130
Boot Options 129
Error Manager 131
Exit 132
H
Main 102
hard drive
Memory
Memory RAS and Performance
Configuration 109
installing 50
hot-plug
Security 120
changing password 122
removing password 122
Supervisor password 120
User password 120
power supply 56
system fan 52
hot-plug PCI card
removing 59
hot-pluggable components 48
Server Management 123
Console Redirection 125
Intel Remote Management
Module 128
System Information 127
BIOS setup 99
entering 100
I
BMC
I/O expansion module
installing 83
specifications
5
BMC module
installing 86
removing 88
removing 85
installing
5.25-inch drive 66
ARMC/3 R2 module 86
BMC module 86
DIMM module 79
C
cold-plug
ARMC/3 R2 module 86
Download from Www.Somanuals.com. All Manuals Search And Download.
186
DVD drive 65
front bezel 42
front system fan assembly 53
HDD 50
hot-plug PCI card 62
I/O expansion module 83
memory board 76
non-hot-plug PCI card 82
power supply 58
processor 68
installing 46
removing 45
processor air baffle 46
processor air duct 46
RAID activation key 93
RAID BBU 95
R
rack
installing 155
RAID activation key
installing 93
RAID cache 93
rear system fan 55
SAS module 89
top cover 44
internal components 11
removing 94
L
LED indicators
hot-plug HDD carrier 22
hot-plug PCI Express slot 25
hot-plug power supply module 24
hot-swap fan module 23
LAN port 25
RAID configuration
memory board 26
M
create RAID1 volume 180
RAID configuration utilities
SAS RAID utility 182
rear system fan
memory
reconfiguring 81
memory board 14
installation order 166
installing 76
memory population 166
removing 74
installing 55
removing 54
memory configuration 163
dual-channel mode 171
memory mirroring mode 175
memory sparing mode 173
single-channel mode 172
removing
ARMC/3 R2 module 88
BMC module 88
DVD drive 64
N
non-hot-plug PCI card
installing 82
removing 82
hot-plug PCI card 59
I/O expansion module 85
memory board 74
non-hot-plug PCI card 82
power supply 57
processor 71
O
opening the system 41
P
peripherals
connecting 32
power off
via hardware 36
via software 36
power on 33
power supply
processor air baffle 45
RAID activation key 94
RAID BBU 96
RAID cache 94
rear system fan assembly 54
SAS module 91
top cover 43
Download from Www.Somanuals.com. All Manuals Search And Download.
187
S
T
SAS module
top cover
installing 89
removing 91
setting up the system 31
preinstallation requirements 31
specification
chipset
control panel
graphic interface
I/O ports
integrated hardware RAID
media storage
memory subsystem
networking
OS
PCI I/O
power supply
processor
SAS controller
serial ATA port
server management
3
5
5
a
server
6
4
cannot detect bootable drive
4
3
5
6
5
7
3
HDD not recognized 142
4
4
5
system fan
storage devices
7
installing 5.25-inch drive 66
replacing DVD drive 64
system boards 12
mainboard 12
processors
not
141
recognized
memory board 14
system features
3
system jumpers 27
system memory
server boot does not complete
POST 141
server turns off often 140
system fans do not rotate 146
resetting the system 137
verifying key system lights 139
turning off the system 36
turning on the system 33
power-on problems 34
reconfiguring 81
system tour
1
system upgrade 37
ESD precautions 39
installation precautions 39
post-installation instructions 40
preinstallation instructions 40
U
upgrading the BIOS 134
Download from Www.Somanuals.com. All Manuals Search And Download.
188
Download from Www.Somanuals.com. All Manuals Search And Download.
|
3D Connexion Swimming Pool XT1500 User Manual
Accton Technology Switch ES5508 User Manual
Acu Rite Weather Radio 06016RM User Manual
Allied Air Enterprises Air Conditioner 4AC18LT User Manual
Amana Range AGG200AA User Manual
AMD Cash Register SB600 User Manual
American Standard Plumbing Product 8473000H User Manual
Axis Communications Printer 540+ User Manual
Axis Communications Security Camera M3007 P User Manual
Beko Hot Beverage Maker BKK2213 User Manual