AMX TV Converter Box AXB REL8 User Manual

instruction manual  
AXB-REL8  
Axcess Relay Controller  
AXlink Bus Controllers  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Table of Contents  
i
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
ii  
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product Information  
Product Information  
The AXB-REL8 Relay Controller provides remote control for up to eight relay functions. Suitable  
for stand-alone or rack mount applications, the AXB-REL8 may be used with AXCESS or  
AXCENT systems via the four-wire AXlink data bus.  
Front and Rear Panels  
The front and rear panels of the AXB-REL8 are shown in FIG. 1.  
Device DIP  
switch  
Relay  
LEDs (1-8)  
AXlink LED  
DEVICE  
AXlink  
1
2
3
4
5
6
7
8
ON  
Relay contacts 1-4  
(shared commons)  
Relay contacts 5-8  
(discrete commons)  
AXlink  
connector  
8
7
6
5
4
3
2
1
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
AXlink  
FIG. 1 AXB-REL8 front and rear views  
Specifications  
The following table details the specifications for the AXB-REL8 Axcess Relay Controller.  
Specifications  
Dimensions (HWD)  
Enclosure  
1.51" x 5.55" x 5.45" (3.84 cm x 14.10 cm x 13.84 cm)  
Non-glare, high-impact black matte plastic  
Power Consumption  
Baseline draw  
• 90 mA @ 12 VDC (min)  
With all 8 relays On  
Weight  
• 170 mA @ 12 VDC (max)  
17.50 oz. (496.11 g)  
Included Accessories  
Optional Accessories  
Metal tab strips included for external adjacent relay communing.  
AC-RK Accessory Rack Kit  
1
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Product Information  
Specifications (Cont.)  
Dimensions (HWD)  
Enclosure  
1.51" x 5.55" x 5.45" (3.84 cm x 14.10 cm x 13.84 cm)  
Non-glare, high-impact black matte plastic  
Power Consumption  
Baseline draw  
• 90 mA @ 12 VDC (min)  
• 170 mA @ 12 VDC (max)  
With all 8 relays On  
Front Panel Components  
AXlink Status indicator  
AXlink LED (green and blinks to indicate AXlink communication activity and  
power:  
• Full-Off indicates no power is being received or the controller is not  
functioning properly.  
• One blink per second indicates power is active and AXlink communication is  
functioning.  
• Full-On indicates there is no AXlink control or activity, but power is On.  
Device DIP switch  
An eight-position DIP switch is used to set the device number for the  
AXB-REL8.  
Relay LEDs 1-8 (Red)  
Illuminate when associated relay is closed. Relay LED's should match panel  
control function.  
Rear Panel Components  
AXlink connector  
Four-pin captive wire receives power and information via the AXlink bus and  
AXlink system controller.  
Relay contacts  
Eight (normally -open) isolated two-pin relay contacts 1 A @ 28 VAC or VDC:  
• Relays 1-4 can share a common if use jumper"A" pins with a tab strip  
• Relays 5-8 use discrete commons (wire commons individually)  
2
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connection and Wiring  
Connection and Wiring  
Setting the DEVICE Dip Switch  
The eight-position Device DIP switch is located on the front panel of the AXB-REL8 as shown in  
FIG. 1 on page 1. Each device in the AXlink bus must have a unique AXlink device number.  
If you later change the device number, remove and reconnect the AXlink connector.  
This enters the new device number into memory. The device number takes effect only  
on power-up.  
2
3
The device can be 1 of the 255 devices in an Axcess, AXCENT, AXCENT , or AXCENT system.  
The device number must match the device assignment in the Axcess program. AMX assigns device  
numbers into the following three segments:  
Cards 1 through 95  
Boxes 96 through 127  
Panels 128 through 255  
Set the device number by setting the DEVICE DIP switch. The device number is the total of all of  
the switches in the ON (down) position. The following table shows the switch numbers and their  
corresponding values.  
Device DIP switch settings  
Position  
Value  
1
1
2
2
3
4
4
8
5
6
7
8
16  
32  
64  
128  
As an example, the following DIP switch (FIG. 2) defines the AXB-REL8 as device number  
97 (1 + 32 + 64 = 97).  
DEVICE  
ON  
1
2
3
4
5
6
7
8
FIG. 2 Example device DIP switch with value of 97  
Set the AXB-REL8 device number before connecting AXlink wiring. Do not install relay wiring at  
this time.  
Wiring Requirements  
The AXB-REL8 uses a four-pin AXlink Central Controller connector for power and data. If the  
distance between the AXB-REL8 and the Central Controller exceeds power consumption limits,  
you must connect an optional 12 VDC power supply. Refer to the following section for more  
information.  
3
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Connection and Wiring  
Do not connect power to the AXB-REL8 until the wiring is complete. If you are using a  
12 VDC power supply, apply power to the AXB-REL8 only after installation is  
complete.  
Preparing captive wires  
To connect the wiring into a captive-wire connector:  
1. Strip 1/4 inch off the wire insulation for all four wires.  
2. Tin 2/3 of the exposed wire.  
3. Insert each wire into the appropriate captive-wire connector up to the insulation.  
4. Tighten the captive screws to secure the fit in the connector.  
Wiring guidelines  
The AXB-REL8 requires 12 VDC power to operate properly. The Central Controller supplies  
power via the AXlink cable. The maximum AXlink wiring distance between the Central Controller  
and AXB-REL8 is determined by power consumption, supplied voltage, and the wire gauge used  
for the cable. The following table lists wire sizes and the maximum lengths allowable between the  
AXB-REL8 and the Central Controller, based on the maximum power consumption rating of 170  
mA (all eight relays ON).  
The maximum wiring lengths for using AXlink power are based on a minimum of 13.5 volts  
available at the Central Controller's power supply.  
Wiring Guidelines at 170 mA  
Wire Size Maximum Wiring Length  
18 AWG  
20 AWG  
22 AWG  
24 AWG  
690.42 feet (210.43 m)  
436.80 feet (133.13 m)  
272.33 feet (83.00 m)  
171.66 feet (52.32 m)  
If the AXB-REL8 is installed farther away from the control system than recommended in the above  
table, connect a 12 VDC power supply to the AXlink connector on the AXB-REL8 rear panel (see  
Wiring AXlink with Optional 12 VDC Power Supply).  
Connecting the Wiring  
The following paragraphs describe wiring connections for using the AXlink and relay connectors.  
If using power from AXlink, disconnect the wiring from the control system before  
wiring the AXB-REL8.  
4
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Connection and Wiring  
AXlink data and power connections  
Connect the control system's AXlink connector to the AXlink connector on the rear panel of the  
AXB-REL8 for data and 12 VDC power as shown in FIG. 3.  
PWR +  
PWR +  
AXP/TX  
AXP/TX  
AXM/RX  
GND -  
AXM/RX  
GND -  
AXB-REL8  
Central Controller  
FIG. 3 AXlink wiring  
Wiring AXlink with optional 12 VDC power supply  
Connect the control system's AXlink connector to the AXlink connector on the rear panel of the  
AXB-REL8 as shown in FIG. 4.  
PWR (+)  
Local +12 VDC power supply  
(coming from the PSN power supply)  
GND (-)  
PWR +  
PWR +  
AXP/TX  
AXP/TX  
AXM/RX  
GND -  
AXM/RX  
GND -  
AXB-REL8  
FIG. 4 Wiring AXlink with Optional 12 VDC power supply  
Central Controller  
Use a 12 VDC power supply when the distance between the control system and AXB-REL8  
exceeds the limits described in the Wiring Guidelines at 170 mA table on page 4, or the power  
supply current capacity cannot accommodate the 170 ma (max) draw of the AXB-REL8. Make sure  
to connect the GND and +12 VDC wire on the AXB-REL8 AXlink connector end. Do not connect  
the optional +12 VDC power supply wire to the control system's power supply side of the AXlink  
connector (FIG. 4).  
Checking the installation  
After set-up is complete:  
1. Check continuity of relay wiring.  
2. Check cable numbers and wiring, interfaces and sources against supplied documentation.  
3. Install tab strips to jumper between shared commons and clip off excess tabs.  
4. Insert relay wiring terminals into AXB-REL8.  
Relay connections  
The relay specification is 1 A @ VAC or VDC. FIG. 5 on page 6 shows the relay wiring diagram  
for the AXB-REL8. The dotted lines are used to indicate commons. Install supplied tab strips to  
jumper between shared commons. Clip off excess tabs and bend strip up, away from other wiring.  
5
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Connection and Wiring  
A
B
A
B
A
B
A
1
2
RELAYS SHARING A COMMON  
Jumper "A" pins with tab strip  
3
4
5
B
A
B
A
B
A
B
A
B
6
7
RELAYS WITH DISCRETE COMMONS  
Wire commons individually  
8
FIG. 5 Relay wiring diagram  
Testing the installation  
1. Check AXlink status LED - it should blink once per second (see Specifications table for  
AXlink status LED).  
2. Relay LED lights, but source does not activate:  
3. Check wiring continuity.  
4. Check jumpers used for shared commons.  
5. Check cable and source against supplied documentation.  
6. Check operational status of interface or source.  
Rack-Mounting the AXB-REL8 (optional)  
To rack-mount the AXB-REL8 into the optional AC-RK Accessory Rack Kit:  
1. Remove any connected relay and AXlink connectors from the rear panel.  
2. Remove the two screws on the front panel of the AXB-REL8.  
3. Remove the front panel and the space bracket behind the panel.  
4. Place the unit in the appropriate opening in the AC-RK.  
5. Place the front panel of the AXB-REL8 on the front of the rack, over the unit.  
6. Fasten the front panel to the rack and to the unit with the two screws you removed.  
6
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Connection and Wiring  
System Worksheet and Installation Guide  
AXB-REL8  
Dealer ID#  
Dealer  
Job  
PO#  
SO#  
Description  
Serial#  
8
7
6
5
4
3
2
1
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
AXlink  
Device #  
Function  
Color/Pin  
AMX Cable/Infc #  
Source  
Wiring  
A
B
A
B
A
B
A
1
2
3
4
5
B
A
B
A
B
A
B
A
B
6
7
8
7
AXB-REL8 Axcess Relay Controller  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
AMX reserves the right to alter specifications without notice at any time.  
brussels • dallas • los angeles • mexico city • philadelphia • shanghai • singapore • tampa • toronto* • york  
3000 research drive, richardson, TX 75082 USA • 469.624.8000 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Network Router 3CRWEASY96A User Manual
Abit Computer Hardware NI8 SLI User Manual
Agilent Technologies Portable Generator 83622B User Manual
Airlink101 Network Router 300N User Manual
AMX Switch NXA ENET24 User Manual
Ask Proxima Projector DP6105 User Manual
Axis Communications Security Camera P3904 R User Manual
Axis Communications Security Camera Q6115 E PTZ User Manual
BB Electronics Network Router Digi One IA User Manual
Beko Freezer CF1100APW User Manual