Radia Eclipse 4-Channel Dimmer Module (120 or 240 volts)  
Overview  
RE-DM4 Specifications (Cont.)  
The RE-DM4 RADIA Eclipse 4-Channel Integrated Dimmer Module (120 VAC:  
FG706-01; 240 VAC: FG706-02) controls up to six circuits with four 1200-watt onboard  
dimmers and two satellite connectors for RDM series dimmer or switch modules  
(FIG. 1). The RE-DM4 is designed for use with the RDA series of enclosures in an  
AMX Lighting™ modular digital dimming system. The RE-DM4 is controlled by AXLink  
or by dry (contact) closures.  
Idle current draw  
75 mA @ 120 VAC, 50 mA @ 240 VAC, 100 mA @ 13.5  
VDC  
RDM control current  
Certifications  
2 at 200 mA @ 12 VDC with no additional power supply  
• FCC  
• CE  
Mounting  
points  
Power Devices  
• UL North America  
• IEC-60950 Safety  
Line In  
Operating Temp Range  
Included Accessories  
• 0° to 40°C (32° to 104°F)  
Jumper  
Neutral  
• 2 4-pin 3.5mm captive wire connector (41-5047)  
• 4 #8-32x1/2” F-point mounting screws  
High  
Voltage  
Connections  
Required Enclosures  
• RDA-ENC2 (FG606-10)  
• RDA-ENC4 (FG606-11)  
Load out  
• RDA-ENC6/6B (FG606-12/13/15)  
• RDA-ENC12B (FG606-14/16)  
Chokes  
Class 1 wiring  
Suggested Loads  
Dimmed  
Switched  
Motors  
Incandescent  
Neon, cold-cathode  
Fans  
Caution: Pre-Installation Notes  
WARNING: This unit should be installed only by qualified electrical personnel, and in  
compliance with all national electrical codes, local codes and ordinances.To prevent  
possible personal injury or death, disconnect power to the enclosure at the breaker  
box before attempting to work with any AMX Lighting modules.  
Class 2 wiring  
All Class 1 and 2 wiring must be connected to their dedicated terminals.  
Class 1 wiring should be connected through the top of the enclosure, and Class  
2 wiring through the bottom.  
Load conductors must be same size as line conductors, regardless of  
connected load.  
Disconnect power while installing or connecting the unit.  
Keep top and bottom air vents clear at all times, and maintain 12” (30.48 cm)  
clearance around the top and bottom.  
Test loads for shorts before connecting.  
Class 2 wiring must be rated 300V or higher.  
For indoor use only.  
AC lighting loads only.  
This module may require extra power from the AXLink connection or an external  
power supply connected to the control card.  
AXLink  
4-Pin Connectors  
Address  
to RDM series  
Modules  
DIP Switch  
Mounting  
points  
External +12V  
Aux Power  
AXlink Connector  
Dry Closures  
FIG. 1 RE-DM4 4-Channel Integrated Dimmer Module  
Specifications  
RE-DM4 Specifications  
Dimensions (HW)  
Weight  
5.75" x 10.0" (146.05 mm x 254.00 mm)  
4.5 lbs (2.04 kg)  
For more information, refer to the RE-DM4 instruction manual available at  
Line Input  
• 120, 240 VAC, single phase, 2W+G, 50/60 Hz, 2400 W,  
one feed  
Radia Lighting System Configuration Pages  
The AMX Radia Web pages provide a simple interface for users of the Radia Duet  
module. The web pages reside on the AMX master when running the Radia Duet  
module and may be accessed through Internet Explorer or Mozilla Firefox. The RE-  
DM4 may also be configured using NetLinx code or a terminal. For more information,  
refer to the RE-DM4 instruction manual available at www.amx.com.  
• 120, 120/240, 240 VAC, single phase, 3W+G, 50/60  
Hz, 4800 W, dual feed  
Output  
• 1200 W max. per channel @120, 240 VAC  
• 2400 W max. total, all four channels on with single  
2400 W feed  
• 4800 W max. total, all four channels on with dual  
2400 W feeds  
High-Voltage Connections  
Each AMX Lighting module has its high-voltage connectors marked on its circuit  
board. Line, load, and neutrals are also clearly marked.  
• Line input #1 goes to dimmer 1 and 3; line input #2  
goes to dimmer 2 and 4  
• All electrical ratings are for continuous duty  
Load  
Line in  
Load  
Neutral  
Wire rating  
Use only copper wires rated at 75°C (167°F) min.  
To 20 in-lbs (2.3 N/M)  
Torque terminals  
Maximum wire size  
Wire stripping length  
AXLink Port  
10 AWG (4 mm²)  
0.5" (13 mm)  
FIG. 2 High-voltage connections  
4-pin 3.5mm black captive wire connector. AXLink  
communication signaling with 12VDC power in.  
Line-in Connections  
Aux Power  
2-pin 3.5mm green captive wire connector. This is a  
12VDC power input that supplies additional power to the  
Radia PCB and connected Radia modules.  
Using two feeds for Line 1 and Line 2 provides two 2400 W inputs.  
With a jumper, Line 1 and Line 2 provides a single 2400 W input (FIG. 3).  
Dry Contacts  
• Emergency fire alarm relay connection - Closed relay  
activates preset 126. Other control is locked out until  
relay opens. Supports daisy chaining of up to 20  
dimmers for this connection, with a maximum current  
requirement of 200mA when daisy-chained.  
Dual 2400 W Inputs without jumper  
Single 2400 W Input with jumper  
• Failsafe connection - Works with a toggle switch -  
opening the switch triggers preset 128, closing the  
switch triggers preset 127. Supports daisy chaining of  
up to 20 dimmers for this connection with a maximum  
current requirement of 200mA when daisy-chained.  
BTU/hr  
300 single feed (2400 W); 600 dual feed (4800 W)  
FIG. 3 Line-in Connections  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

3Com Cable Box 3CR856 95 User Manual
3M Food Saver 18900 User Manual
Abocom Network Router FM56CC User Manual
AKG Acoustics Microphone C414 XLII User Manual
American DJ Laser Pointer IMAGE 8 DMX User Manual
Atlantis Land Switch A07 ES4612 User Manual
Audiovox Car Stereo System AVD400T User Manual
Avery Door 6032 User Manual
Axis Communications Printer AXIS 5400+ User Manual
BC Speakers Speaker System 6 XT 13 User Manual