Safety Instructions  
Overview  
Please read these instructions before using your AMX Solecis device. Failure to  
comply with these instructions could result in fire, electrical shock, personal injury,  
death, or damage to the equipment.  
The Solecis AVB-DA-RGBHV-0106 1:6 RGBHV Distribution Amplifier  
(FG1340-4516-01) is a 1 in 6 out RGB HV distribution amplifier on BNC  
connectors. All outputs are 75 ohm driven for connection to long cable runs.  
Power Source  
The high performance wide bandwidth circuitry ensures compatibility across all  
resolutions and the AVB-DA-RGBHV-0106 can be used for RGBHV, RGBS,  
RGsB, YUV, and composite video.  
Use only a 3-wire grounding type source. The power source should not exceed  
264VAC. Do not remove under any circumstances the ground wire.  
Power Cord  
The AVB-DA-RGBHV-0106 is housed in a 1U metal enclosure and features an  
internal 100-240V power supply.  
Use only the cord shipped with the unit. Do not use the cord if it has become damaged  
or frayed. Contact your AMX Solecis dealer if you need to replace the power cord.  
Grounding  
(front)  
The interface is grounded through the grounding conductor on the power cord. To  
avoid electric shock plug the power cord into a properly wired receptacle. Do not  
defeat the purpose of the grounding-type plug.  
Fuse  
For protection against the risk of fire, use only a fuse of the same rating and type.  
Liquid Spills  
Do not set drinks on top of the unit or immerse the unit in liquid.  
Do Not Disassemble  
This device contains no user serviceable parts. All servicing must be performed by a  
qualified service technician.  
(rear)  
FIG. 1 Solecis AVB-DA-RGBHV-0106  
For Safety Reasons  
Product Specifications  
Do not place the unit on an unstable surface.  
Do not use near water or sources of heat.  
Use only recommended attachments.  
Use the type of power supply as specified.  
AVB-DA-RGBHV-0106 Specifications  
RGB Input  
Unplug the power to the unit and refer servicing to qualified personnel under the  
following conditions:  
Number:  
1
If liquid has been spilled or the unit has been exposed to rain or water.  
If it does not operate normally when the operating instructions are followed or if it  
exhibits a distinct change in performance indicating a need for service.  
If the unit has been dropped or the cabinet damaged.  
Connector:  
Level:  
BNC  
Analog  
1V p-p  
75 ohm  
Max Level:  
Connections  
Connect the PC input and outputs on the rear panel of the unit.  
Impedance:  
Sync Input  
Type:  
Note: It is imperative that the input source is fully compatible with the display  
devices.  
Analog or TTL  
Impedance:  
RGB Video Bandwidth:  
RGB Return Loss:  
75 ohm  
The RGB input is 75 ohm terminated and the outputs fully 75 ohm driven for  
connection to long cable runs.  
350MHz -3dB  
The unit can now be connected to the mains and the power switched on.  
-40dB@10MHz, -27dB@100MHz  
Adjacent Channel X-talk: -70dB@10MHz, -48dB@100MHz  
RGB Output  
Number:  
Connectors:  
Level:  
6
BNC  
Analog  
Unity  
75 ohm  
Gain:  
Impedance:  
Sync Output  
Level:  
TTL  
Impedance:  
Power  
75 ohm  
Input Voltage:  
Power Consumption:  
Dimensions (HWD):  
Weight:  
100-240V 50/60Hz  
8W  
1.73” x 17.36” x 6.69” (4.4cm x 44.1cm x 17.0cm)  
5.73 lbs. (2.6kg)  
Certifications:  
• CE  
• UL60950  
• FCC class B, part 15  
• RoHS/WEEE compliant  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Addonics Technologies Computer Drive AD25MSD User Manual
AEG Cooktop HK654200FB User Manual
Aiphone Home Security System NDR 10A User Manual
Allied Telesis Home Security System AR450S User Manual
Amana Refrigerator ASD2522VRB00 User Manual
Audiovox Car Stereo System AVD400TA User Manual
Baldor Microwave Oven MN781 SUP User Manual
BB Electronics Network Card HVD100A3 User Manual
BC Speakers Portable Speaker WG400 User Manual
Beko Flat Panel Television 19WLM550DHID User Manual