ISDN NT1 1010
1010PA
ISDN Network Termination Unit
Part Number: 65-10100101
Download from Www.Somanuals.com. All Manuals Search And Download.
Copyright 1998. ADC Kentrox. All Rights Reserved.
Specifications published here are current or planned as of the date of publication
of this document. Because we are continuously improving and adding features to
our products, ADC Kentrox reserves the right to change specifications without
prior notice. You may verify product specifications by contacting our office.
The information in this document is subject to change without notice.
ADC Kentrox shall not be liable for technical or editorial errors or omissions
which may occur in this document; nor for the incidental or consequential dam-
ages resulting from the furnishing, performance, or use of this document. This
document contains information protected by copyright. No part of this document
may be reproduced in any form without the prior written consent of ADC Ken-
trox.
Document printing history
Part #
Date
Description
65-10100101
December, 1998
Issue 1
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Important safety information
This symbol on the product alerts the user to the presence of important
operating and maintenance (servicing) instructions in the literature accom-
panying the product.
This equipment has been designed to the highest quality standards of materials,
workmanship and safety. Do not bypass any of the safety features of this equipment
or operate it in an improper environment.
WARNING!
To avoid hazard from electrical shock and/or fire, adhere to the
safety practices listed in this section and identified within the
instructions of this document.
Use normal caution when installing or modifying telephone lines. Dangerous volt-
ages may be present.
■
■
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.
■
Never touch uninsulated telephone wires or terminals unless the telephone
line is disconnected at the network interface. Always disconnect all tele-
phone lines at the network interface, and power connections from the wall
outlets before servicing or disassembling this equipment.
All wiring external to the product(s) should follow the provisions of the current edi-
tion of the National Electrical Code or any national wiring rules that apply.
WARNING!
Potentially hazardous voltages inside. Service should be
performed only by qualified personnel.
CAUTION!
For continued protection against risk of fire, replace only with
same type and rating of fuse "F1", located on printed circuited
wiring board. 125V, 1.5A.
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty information
ADC Kentrox warranties to Buyer that the products or services are free from sub-
stantial defects and workmanship under normal use given proper installation and
maintenance for the period of 60 months from the date of original shipment.
Buyer will promptly notify ADC Kentrox of any defect in the product or service.
ADC Kentrox or its agent will have the right to inspect the product or workmanship
on Buyer’s premises. ADC Kentrox has the option to (a) repair, replace or service at
its factory or on Buyer’s premises the product or workmanship found to be defec-
tive; or (b) credit Buyer for the product or service in accordance with ADC Ken-
trox’s credit procedure. Refurbished material may be used to repair or replace the
product. Products returned to ADC Kentrox for repair, replacement, or credit will be
shipped prepaid by ADC Kentrox during the warranty period. Upon expiration of
the warranty, freight will be prepaid by the Buyer.
Limitation of warranty
ADC Kentrox assumes no warranty liability with respect to defects in the product
caused by: (a) modification, repair, installation, operation, or maintenance of the
product by anyone other than ADC Kentrox or its agent, except as described in ADC
Kentrox’s documentation; or (b) the negligent or other improper use of the product.
Other manufacturer’s equipment purchased by ADC Kentrox and resold to Buyer
will be limited to that manufacturer’s warranty. ADC Kentrox assumes no warranty
liability for other manufacturer’s equipment furnished by the Buyer.
No agent, distributor, or representative is authorized to make any warranties on
behalf of ADC Kentrox or to assume for ADC Kentrox any other liability in connec-
tion with any ADC Kentrox product or service.
The equipment may contain reconditioned parts, but those parts will be subject to
the same specifications and quality control standards we apply to new materials and
will be warranted as if they were new.
Disclaimer of warranty and limitation of remedies
BUYER UNDERSTANDS AND AGREES AS FOLLOWS:
■
THE ABOVE WARRANTY REPLACES ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, AND ALL OTHER OBLIGATIONS OR
LIABILITIES OF ADC KENTROX, INCLUDING ANY WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE. ALL OTHER WARRANTIES ARE DISCLAIMED AND
EXCLUDED BY ADC KENTROX.
■
THE FOREGOING WILL BE THE SOLE AND EXCLUSIVE REMEDY
WHETHER IN CONTRACT, TORT, OR OTHERWISE AND
ADC KENTROX WILL NOT BE LIABLE FOR INJURIES OR DAM-
AGES TO PERSONS OR PROPERTY RESULTING FROM ANY
CAUSE WHATSOEVER, WITH THE EXCEPTION OF INJURIES OR
v
Download from Www.Somanuals.com. All Manuals Search And Download.
DAMAGES CAUSED BY THE GROSS NEGLIGENCE OF
ADC KENTROX.
■
THIS LIMITATION APPLIES TO ALL SERVICES AND PRODUCTS
DURING AND AFTER THE WARRANTY PERIOD. IN NO EVENT
WILL ADC KENTROX BE LIABLE FOR ANY SPECIAL, INCIDEN-
TAL, OR CONSEQUENTIAL DAMAGES OR COMMERCIAL LOSSES
EVEN IF ADC KENTROX HAS BEEN ADVISED THEREOF.
Transfer of product ownership from original purchaser (other than VARS or distrib-
utors) voids existing warranties of any kind.
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
Who to call for assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 2 Setting up your hardware
Chapter 3 Installing your unit
Wiring instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wall mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Power source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Chapter 4 S/T bus configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Chapter 5 Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
This manual explains how to install, power up, and configure the 1010PA ISDN
Network Termination Unit.
Who is this manual for?
This manual is for the person installing an ISDN NT1 unit. It contains everything an
installer needs to know to power on the unit and confirm that it is functioning cor-
rectly.
Who to call for assistance
If you need assistance with this product, or have questions not answered by this
manual, you are welcome to call our Technical Support service. Before doing so,
please have the product’s model number and serial number available to give to
your Technical Support representative.
1-800-733-5511 (continental USA only)
1-503-526-6199
If you ever need to return your unit to ADC Kentrox for repair, first call our Cus-
tomer Service department at the numbers above and obtain a Return Authorization
(RA) number. ADC Kentrox does not accept returns without an RA number.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
C
H
A
P
T
E
R
1
Introduction
The 1010 is a compact, versatile, and affordable Network Termination 1 (NT1)
device. The 1010 is used for connecting Integrated Services Digital Network
(ISDN) voice or data Terminal Equipment (TE) to the ISDN line provided by the
telephone company.
The NT1 is pictured in Figure 1. Three LEDs on the front panel indicate the status of
the power, the S/T & U interfaces, and Central Office (CO) loopback testing.
This installation guide describes how to install the 1010 for use with ISDN TE(s).
The 1010 may be mounted on a wall or simply placed on a desktop.
Figure 1—1010 NT1 physical dimensions
3.9”
5.7”
1.3”
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
C
H
A
P
T
E
R
2
Setting up your hardware
Taking inventory
The 1010 package contains the following items:
■
■
■
■
■
■
■
■
■
One 1010 unit
One RJ11 to RJ45 cable
One RJ45 to RJ45 cable
One power supply unit (AD62010)
One plastic wall mount bracket
Two jumpers
Two screws and two plastic anchors for wall mounting
User’s Guide
One warranty card
Front panel LEDs
There are three (3) LEDs on the front panel of the 1010.
Figure 2—1010 NT1 front panel
U
LOOP
BACK
POWER
S/T&U
Power LED
When the 1010 is plugged into the wall outlet, the POWER LED will be on.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
S/T&U LED
The S/T&U LED will flash for a few seconds when the 1010 is first powered on.
This LED will then go off, provided that the S/T & U interfaces are working prop-
erly.
a
If there is no ISDN line connected to the U-interface or the line is not acti-
vated, then the S/T&U LED will be on continuously.
b
If the U-interface is detected, but is not in sync., the S/T&U LED will flash
eight times per second. In this case, the S/T device will not work until
sync. is restored on the U-interface.
c
d
If the U-interface is in sync., but the S/T-interface is not, then the S/T&U
LED will flash once per second. There must be an S/T device connected to
the S/T-interface before this light will go off.
Once both the S/T- and U-interfaces are in sync., the S/T&U LED will go
off.
Loopback LED
The U LOOP BACK LED will light only during a telephone company full "2B+D"
loopback test. The ISDN line will not be available until this testing is completed.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
C
H
A
P
T
E
R
3
Installing your unit
Rear panel
1
The 1010 rear panel (see Figure 3) has three RJ45 connectors, two for the
S/T-interface and one for the U-interface.
2
The two RJ45 connectors for the S/T interface, located on the left side of
the rear panel, are connected in parallel internally. When one RJ45 connec-
tor is being used, the maximum range is 3,300 feet (1,000 meters). When
both RJ45 connectors are being used, the total range on both shall not
exceed 660 feet (200 meters). The RJ45 pin connector assignments for the
S/T interface are shown in Table 1.
Figure 3—1010 NT1 rear panel
S/T
S/T
U
Table 1—S/T interface (RJ45) connector pin assignments
Pin
Function
Pin
Function
1
3
6
7
—
2
4
5
8
—
RX +
RX -
TX +
TX -
GND
-40 VDC
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2—U interface pin assignments
Pin
Function
Pin
Function
1
3
5
7
—
2
4
6
8
—
—
TIP
—
RING
—
—
Power connector
The 4-pin mini DIN power connector is located on the side of the 1010. This design
will prevent the weight of the 1010 power adapter from accidentally pulling off,
when the 1010 is wall mounted. The power connector pin assignments are shown in
Table 3.
Table 3—Power connector pin assignments
Pin
Function
Pin
Function
1
3
+9 VDC
2
4
- 40 VDC
GND for 9V
GND for -40V
DIP switch setting
A block of four DIP switches is located on the bottom of the 1010. Use the DIP
switches to configure the 1010 according to the settings shown in Table 4. For S/T
wiring configuration, please refer to Chapter 4.
Table 4—Dip switch pin assignments
Switch
Function
On
Off
1, 2
3
S/T - termination
Bus timing mode
Yes *
No
Short passive
bus
Point-to-point, or
extended passive bus
4
Spare
N/A *
N/A
* = default setting
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Internal jumper settings
The 1010 is shipped with 100Ω Termination Resistance (TR). This TR is added to
the S/T bus when dip switches 1 & 2 are set to the on position. If the installed S/T
bus ISDN CPE provides 100Ω TR, dip switches 1 & 2 should be set to the off posi-
tion to provide 0Ω. When the ISDN CPE provides 50Ω, the 1010 needs to be
adjusted to provide the other 50Ω, instead of its default of 100Ω. Changing the 1010
TR is done through an internal jumper. Following is the procedure to change the
internal jumper.
WARNING!
Always disconnect all telephone lines at the network interface,
and power connections from the wall outlets before servicing
or disassembling this equipment.
1
2
To open the 1010, remove the four corner screws from the bottom of the
1010.
On the component side of the printed circuit board, locate JP3 & JP4 (in
the middle of the board). Table 5 shows the setting of the dip switch 1 & 2
for different Termination Resistance settings.
Table 5—Jumper setting for termination resistance
Dip Switch
1 & 2
JP3 & JP4
not jumpered
JP3 & JP4
jumpered
ON *
OFF
100 ohms *
0 ohm
50 ohms
0 ohm
* factory default
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring instructions
Figure 4 shows the wiring diagram of the 1010 with the ISDN Customer Premise
Equipment (CPE) and the Line Termination (LT). Follow the instructions given
below to set up the 1010:
Figure 4—Wiring diagram
1
2
Adjust the DIP switches for the desired S/T wiring setup (see Table 4).
Connect the DC power plug of the AD62010 to the power connector on the
side of the 1010.
3
4
5
Plug the AD62010 into the AC power outlet. The POWER LED will light
and the S/T&U LED will light or flash depending on the line status.
Connect one end of the RJ45 cable into the U-interface connector on the
1010. The other end goes into the U-interface wall outlet.
Switch on the power to the ISDN terminal equipment. Connect one end of
the RJ45 cable provided, to one of the S/T connectors on the 1010, and
connect the other end to the ISDN TE.
6
7
If a second ISDN TE will be used, repeat step 5 to connect the second ter-
minal to the second S/T connector.
The S/T&U LED may begin to flash for a few seconds. The LED will go
off when the communication paths have linked. When the LED goes off,
the ISDN CPE is ready for communication.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Wall mounting instructions
To mount the 1010 on a wall, follow these instructions.
1
2
3
4
5
Drill two holes in the wall corresponding to the holes on the wall mount
bracket provided with the 1010.
Insert the plastic wall anchors into the wall holes, using a hammer if neces-
sary.
Align the bracket with the anchors, and use the screws provided to mount
the bracket on the wall.
Align the holes on the back of the 1010, with the hooks on the wall mount
bracket.
Press the 1010 gently but firmly onto the mounting bracket. Then slide the
1010 down gently until it hooks onto the bracket and locks into position.
Figure 5—Wall mounting
Power source
Use the 1010 only with power adapter model AD62010. The power adapter sup-
plies power to the NT1 only.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
C
H
A
P
T
E
R
4
S/T bus configuration
The 1010’s dip switch settings relate to the five possible
configurations of the S/T bus. The 1010 allows the user to
adjust the S/T bus Termination Resistance (TR) and S/T bus
timing.
Figure 6—End of Passive Bus (P-P)
TE.
DIP SWITCHES
1010
O 1
2
3
4
N
TR
3300 ft.
Figure 7—Short Passive Bus (Point-to-Multipoint)
TE.1
TE.2
DIP SWITCHES
1010
O 1
2
3
4
N
TR
TR
660 ft.
Figure 8—Short Passive Bus (Linear)
TE.1
TE.8
DIP SWITCHES
1010
O 1
2
3
4
N
TR
660 ft.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 9—Extended Passive Bus (Cluster Multipoint)
TE.1
TE.4
DIP SWITCHES
1010
O 1
2
3
4
N
TR
1600 ft.
Figure 10—Extended Passive Bus (Linear)
TE.1
TE.4
DIP SWITCHES
1010
O 1
2
3
4
N
TR
100 ft.
1600 ft.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
C
H
A
P
T
E
R
5
Specifications
Table 6—Specifications
Parameter
Specification
Physical
Height - 1.3"
Width - 3.9"
Depth - 5.7"
Weight - 1.0 lb.
Environment
Complies with AT&T Pub. 62310.
0°C to 60°C (32°F to 140°F)
-25°C to 60°C (-13°F to 140°F)
0% to 95% noncondensing
Operating temperature
Storage temperature
Relative humidity
Power
+7.5 VDC with 1W dissipation
Provides automatic lightning and surge
protection for the S/T and U interfaces
Power adapter option
Network Interface
Line
Provides power to the NT1 only
Automatic ANSI maintenance functions
Two-wire, full duplex
Data rate
144 kbps available to customer
2B1Q per ANSI T1.601, 1992
2.5V, zero-to-peak
Line code
O/P amplitude
Connector
One RJ45 or one RJ11
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 6—Specifications
Parameter
Specification
Terminal S/T interface
Supports point-to-point and multipoint
Conforms to ANSI T1.605, 1991-TX source
impedance, RX impedance, receive sensitivity
Line
Four-wire, full duplex
144 kbps available to customer
AMI, 100% duty cycle
0.75V, zero-to-peak
Two RJ45
Data rate
Line code
O/P amplitude
Connector
DIP switches
S/T interface termination
S/T bus timing mode
LED indicators
Front panel power status lamp
S/T and U line error status lamp
U loopback status lamp
Mounting Options
Regulatory
Standalone desktop or wall mount
FCC part 15, Class B approval
UL 1459 approval
DOC CS03 approval
CUL CSA-235 approval
FCC compliance information
This device complies with part 15 of the FCC rules. Operation is subject to the fol-
lowing conditions: 1) This device may not cause harmful interference, and 2) this
device must accept any interference received, including interference that may cause
undesired operation.