USER MANUAL
E
T
H
E
R
N
E
T
1
B
0
R
B
I
D
a
G
s
E
e
T
LINK
Campus-REX RS Interface Card
Catalog Number: CAD1069I5 Issue 5
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC Notice
FCC NOTICE
This unit complies with the limits for a Class A digital device, pursuant to
Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the situation by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Consult the dealer or an experienced radio or television technician
for help.
Any changes or modifications not expressly approved by the grantee of this
device voids the user’s authority to operate the equipment.
Campus-REX RS Interface Card User Manual
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Using This Manual
USING THIS MANUAL
This manual documents the Campus-REX® RS Interface Card (part number
150-1175-51). It includes information on how to:
•
install the card in either a Campus-RS™ Desktop Unit (150-1158-01,
150-1158-02, 150-1158-51, or 150-1158-52) or Campus-Star® chassis
(150-1220-01, 150-1220-02, or 150-1220-51)
•
•
•
configure the Campus-REX to operate as a bridge or a router
monitor the Campus-REX
contact ADC for assistance.
DOCUMENT CONVENTIONS
Two types of messages, identified by icons, appear in the text.
Notes contain information about special circumstances.
Cautions indicate the possibility of personal injury or
equipment damage.
This manual uses the following conventions:
•
Keycaps, such as ESC , indicate keys that you press on a terminal
keyboard.
•
Key names in bold font indicate buttons on the desktop unit or line unit
that you press.
For a list of abbreviations used in this manual, see “Abbreviations” on
page B-1.
iv
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Unpack and Inspect the Shipment
UNPACK AND INSPECT THE SHIPMENT
Upon receiving the Campus-REX RS Interface Card:
1
Unpack the card and inspect it for signs of damage. If it has been
damaged in transit, report the extent of the damage to the transportation
company and to your sales representative immediately. Order
replacement equipment if necessary.
2
Compare the contents of the package against the packing list to ensure a
complete and accurate shipment. If the shipment is incomplete or
incorrect, contact ADC as described in “Contacting ADC” on page D-1.
If you need to store the unit for several days or more before installing it, return
it to the original packaging.
Campus-REX RS Interface Card User Manual
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Unpack and Inspect the Shipment
vi
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Chapter 1: About the Product_________________________1-1
Product Features..................................................................................1-2
Establishing an HDSL Link ................................................................1-5
Application..........................................................................................1-6
Point-to-Point LAN Extension..............................................1-6
Interface Card ____________________________2-1
Install the Card ....................................................................................2-1
Installing into a Campus-Star Chassis ..................................2-3
Connect the Ethernet Line...................................................................2-4
Chapter 3: Set Up the Campus-REX System_____________3-1
Set Up an ASCII Terminal..................................................................3-2
Connecting the ASCII Terminal to the Campus Unit...........3-3
Logging Onto the Terminal ..................................................3-5
Set the HDSL Operating Mode ...........................................................3-7
Using the LCD ......................................................................3-8
Campus-REX RS Interface Card User Manual
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Configure the Campus-REX as a Bridge or Router...........................3-19
Entering Port Addresses........................................3-26
Set the Timing Source........................................................................3-29
Chapter 4: Configuring and Monitoring
through the LCD _________________________ 4-1
Navigating the LCD Menus.................................................................4-2
Restoring the System to Default Values..............................................4-3
Configuring the Campus-REX as a Master or Slave Unit...................4-4
viii
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Viewing System Information ............................................................4-12
Viewing Status Information ..............................................................4-13
Chapter 5: Configuring with an ASCII Terminal_________5-1
Setting Up and Logging On to an ASCII Terminal.............................5-2
Logging Onto a Remote Campus Unit................................................5-3
Logging Off of a Campus Unit............................................................5-3
Campus-REX RS Interface Card User Manual
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Configuring Loopbacks .....................................................................5-20
Initiating a Loopback...........................................................5-22
Chapter 6: Monitoring with an ASCII Terminal_________ 6-1
Monitoring HDSL Performance ..........................................................6-2
24-Hour Performance History...............................................6-4
Seven-Day Performance History...........................................6-5
Viewing Local Alarm History .............................................................6-6
Viewing Ethernet Statistics..................................................................6-8
Viewing Product Information ............................................................6-10
x
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Overview ________________________________7-1
Static IP Routing .................................................................................7-4
SNMP..................................................................................7-11
Campus-REX SNMP Agent ...............................................7-12
Appendix A: Technical Reference _____________________ A-1
Specifications ..................................................................................... A-1
Default Settings .................................................................................. A-2
LCD Menu Reference ........................................................................ A-3
ASCII Terminal Menu Reference ...................................................... A-5
Appendix B: Abbreviations __________________________ B-1
Appendix C: The Documentation Set __________________ C-1
Campus-REX RS Interface Card User Manual
xi
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Product Support ..................................................................................D-1
Advance Replacement ........................................................................D-2
Billing .................................................................................................D-2
Index _____________________________________________ E-1
xii
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
ABOUT THE PRODUCT
The Campus® Remote Ethernet eXpress (Campus-REX) RS Interface Card
installs into a:
1
•
Campus-Star® chassis, along with a Campus-RS™ (Rate Selectable)
Line Unit
•
Standalone Campus-RS Desktop Unit
This comprises half of a High-bit-rate Digital Subscriber Line (HDSL)
transmission system. When connected to another Campus-RS, Campus-T1®,
Campus-768®, or Campus-E1® Desktop Unit or Line Unit, the Campus-RS
system can transport digitized voice, data, and video signals over existing
copper wire at a number of different HDSL rates.
This version of the Campus-REX must be installed in a
Campus-RS or Campus-HRS Desktop Unit or with a
Campus-RS or Campus-HRS Line Unit. It cannot be installed
in an older Campus Desktop Unit or with an older Campus
Line Unit.
The Campus HDSL system provides a connection between geographically
distributed Ethernet Local Area Networks (LANs) in a campus environment.
To provide the connection, the Campus-REX performs transparent 802.3
MAC bridging or static IP routing over an HDSL line. You can use existing
telephone-grade copper wiring as the HDSL transmission medium.
Campus-REX RS Interface Card User Manual
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
About the Product
PRODUCT FEATURES
The Campus-REX provides complete main bridging tasks such as dynamic
address learning, forwarding, filtering, and hashing/buffer management.
Other features include:
•
•
embedded Simple Network Management Protocol (SNMP) agent
IEEE 802.1d transparent MAC level bridging with Spanning Tree
protocol support
•
•
•
static IP Routing
BOOTP for configuration of IP parameters
HDLC (High-level Data Link Control) or PPP (Point-to-Point Protocol)
frame encapsulation options
•
•
10BASE-T port for connection to an 802.3 LAN
console port for maintenance and management
COMPATIBILITY WITH EARLIER CAMPUS
PRODUCTS
When mated with a Campus-RS Desktop Unit or Campus-RS Line Unit, the
Campus-REX RS Interface Card is compatible, over the HDSL link, with
earlier versions of Campus products, such as the Campus-T1, Campus-E1,
and Campus-768, as shown in the following illustration. Campus-RS units are
not currently compatible with Campus-384 products.
Campus-T1, Campus-E1 or
Campus-RS
Campus-768
Campus-REX T1,
Campus-REX E1, or
Campus-REX 768
Campus-REX RS
Interface card
HDSL
1-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
About the Product
All earlier versions of Campus products are manufactured to operate at a
single HDSL transmission rate, while the Campus-RS transmission rate is
user-selectable. To support compatibility with earlier Campus Products, the
following configuration options must be set on the Campus-REX:
•
•
Set the HDSL Operating Mode to Standard Mode.
Set the Standard Mode HDSL Rate to T1, E1, or 768, to match the rate
of the earlier product.
If a Campus-RS unit is connected over an HDSL link to an earlier Campus
product, and if either unit has the HDSL Transceiver (XCVR) Mode set to
AUTO, the HDSL link may not operate properly.
When operating the Campus-RS product with an earlier version of the
Campus products, to avoid any problems with link startup or operation, it is
recommended that the Transceiver Mode be set as follows:
•
•
Campus-RS = MASTER
Campus E1/T1/768 = SLAVE
If one or both units are already set to AUTO and the HDSL link is active,
disconnect the HDSL link, change the settings as recommended, and
reconnect the link. This will assure the link integrity on any subsequent
startups.
This situation does not apply to a circuit with two Campus-RS
units. You may leave the units set to their default setting of
AUTO, and they will operate properly.
For information on setting these options, see “Set the HDSL Operating
Mode” on page 3-7.
Campus-REX RS Interface Card User Manual
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
About the Product
COMPATIBILITY WITH CAMPUS-RS PRODUCTS
The Campus-REX RS Interface Card is also compatible, over the HDSL link,
with another Campus-RS unit, as shown in the following illustration.
Campus-RS
Campus-RS
Campus-RS
Interface card
Campus-REX RS
Interface card
HDSL
When connecting to another Campus-RS Desktop Unit or Line Unit,
Standard Mode is still supported, providing access to HDSL transmission
rates of T1, E1 and 768 kbps. In addition, the Campus-RS system can be
configured to support an extended set of HDSL transmission rates, over either
one or two HDSL loops.
To support these additional transmission rates, set the following options on
the Campus-REX:
•
•
Set the HDSL Operating Mode to Extended Mode or AutoSync Mode.
Set the Extended Mode Loop Configuration to 1 Loop or 2 Loops,
depending on the physical layout of your HDSL network.
•
Set the Extended Mode HDSL Rate to the desired setting.
1-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
About the Product
The range of rates available for the HDSL Rate depends on the setting of
the Extended Mode Loop Configuration:
–
1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments
–
2 Loop HDSL Rate settings are between 256 kbps and 2.304 Mbps,
in 128 kbps increments
Not all of these modes and rates are available if the remote
Campus-RS system does not support them. Refer to the
remote interface card User Manual to see the HDSL modes
and rates supported by the card.
For information on setting these options, see “Set the HDSL Operating
Mode” on page 3-7.
ESTABLISHING AN HDSL LINK
Before an HDSL link can be established in Standard or Extended Mode, the
HDSL parameters for both the local and remote units must be set identically.
Using AutoSync Mode allows one unit to determine the HDSL parameters.
In AutoSync Mode, one unit is configured as a master and the other as a slave.
Upon startup, the HDSL parameters of the master unit are used to establish
the HDSL link. No further configuration of the slave unit is required.
If the remote unit is not configured as an AutoSync slave, an AutoSync
connection will not be established and the system generates an AutoSync
minor alarm. After several failed attempts, the master enters Fallback Mode
and attempts to establish a normal HDSL link with the same HDSL
parameters. If this is unsuccessful, for example, if the slave unit is configured
to a different HDSL Rate, the master unit reverts to attempting to establish an
AutoSync connection.
Campus-REX RS Interface Card User Manual
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
About the Product
APPLICATION
When installed in a Campus-RS Desktop Unit or Campus-Star chassis, the
Campus-REX functions as a remote bridge or static IP router.
You can use the Campus-REX to extend subnetworks to remote sites within
a campus. Or, for sites separated by greater distances, you can use the
Campus-REX to connect them through a public T1/E1 Wide Area Network
(WAN). See “Point-to-Point LAN Extension” and “LAN Connections Over
a WAN” on page 1-7 for more information.
Campus-REX software provides complete main bridging tasks of learning,
forwarding, filtering, and hashing/buffer management, 802.1d Spanning Tree
protocol, 802.3 drivers, packet sequencing, segmentation and reassembly,
and other local tasks. The Campus-REX is specifically designed for
10BASE-T LANs that use unshielded twisted pair (UTP) segments with
reach of more than 100 meters and that require low-cost, high performance
connectivity.
The Campus-REX performs full-bandwidth filtering on the 10BASE-T port,
and forwarding at the selected transmission rate.
Point-to-Point LAN Extension
As organizations move or change, LANs also evolve and may become
fragmented or physically separated. The Campus-REX provides a lower-cost
alternative to other LAN-extension solutions. The Campus-REX provides a
built-in 10BASE-T LAN interface that eliminates the need for other
internetworking devices while providing 30 times the performance of other
sub-rate wireless connectivity options, as shown in the following figure.
1-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
About the Product
LAN Connections Over a WAN
When LANs are distributed over a large physical area (such as within a
metropolitan area) or cabling is not available between sites, you can lease
appropriate unloaded copper pairs from a local carrier for LAN connectivity.
For transport over public networks, you can connect the public T1 network
(DSX-1 signal) to the LAN through Desktop Units with CSU/DSX-1
interface cards and the Campus-REX in a Desktop Unit. This application, as
shown in the following figure, simplifies access to public high-speed WANs
for LAN connectivity to remote sites.
LAN
10BASE-T
Campus-RS
Campus-RS
Campus-REX
Campus-REX
10BASE-T
LAN
DSX-1
WAN
LAN
10BASE-T
Campus-REX
LAN
LAN
10BASE-T
10BASE-T
Campus-REX
Campus-REX
Campus-Star
Public T1
Network
DSX-1
LAN
10BASE-T
Campus-T1
Campus-REX
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
1-7
About the Product
LAN Extension in a Routed Environment
The Campus-REX, set for bridging over PPP, can extend LAN access to a
centralized router. This application, as shown in the following figure, requires
two settings for the remote Campus-REX units:
•
•
set the Bridge/Router mode to Bridge
set the Encapsulation to PPP
LAN
LAN
10BASE-T
10BASE-T
Campus-RS
Campus-RS
Campus-REX
Campus-REX
V.35
LAN
10BASE-T
Campus-REX
V.35
External
network
LAN
LAN
10BASE-T
10BASE-T
Campus-REX
Campus-REX
Campus-Star
Router
connections
V.35
LAN
10BASE-T
Campus-T1
Campus-REX
In this application, the router ports must be configured for
bridging with PPP encapsulation.
1-8
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING
THE CAMPUS-REX RS
2
Campus-RS Line Unit.
To Learn How to:
See Page:
Install the Card
2-1
2-4
2-7
Connect the Ethernet Line
Power Up and Check the Ethernet Line
INSTALL THE CARD
The following sections describe how to install the Campus-REX RS Interface
Card.
Make sure you install the Campus-REX into a Campus-RS
Desktop Unit or into a Campus-Star chassis with a
Campus-RS Line Unit. The Campus-REX will not operate if it is
installed in an earlier version of these Campus products.
Ensure you read important information on surge protection
for HDSL line installation in the line unit or desktop unit
manual before installing the interface card.
Campus-REX RS Interface Card User Manual
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Campus-REX RS Interface Card
Installing into a Campus-RS Desktop Unit
This section describes how to install the Campus-REX into a Campus-RS
Desktop Unit.
Turn off the power on the Desktop Unit before you install the
card. Installing the card with the power on may cause damage
to the Desktop Unit, the card, or both.
1
Slide the card into the guide rails in the rear of the Desktop Unit.
Campus-RS Desktop Unit chassis
Guide rail
Campus-REX RS
Interface card
C
A
M
P
U
S
-
R
S
120
or 220
V
A
C@60Hz
V
A
.2A MCa@x50Hz
6
3
1
E
T
H
E
CFGRN
E
T
B
R
I
D
G
E
L
IN
E
1
0
B
a
L
s
e
I
N
T
K
2
Gently press the card into place until it is seated firmly in the mating
connector.
3
4
Use the two screws on the card to secure it into place.
To connect the Campus system to an HDSL line, see the Campus-RS
Desktop Unit User Manual.
2-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Campus-REX RS Interface Card
Installing into a Campus-Star Chassis
This section describes how to install the Campus-REX in a Campus-Star
chassis.
Before installing the Campus-REX, make sure there is not a
Line Unit installed in the corresponding slot on the front of the
Campus-Star chassis. The Campus-REX is not
hot-swappable. Installing the Campus-REX with a
corresponding Line Unit installed may cause damage to the
Campus-REX, the Line Unit, or both.
1
Slide the card into the guide rails in the desired slot on the rear of the
Campus-Star chassis.
DSX
DSX
-
X
S
620
FG
C
D
X
S
D
G
620
F
C
Campus-Star
chassis
FG
C
Campus-REX RS Interface card
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
2-3
Installing the Campus-REX RS Interface Card
2
Gently press the card into place until it is seated firmly in the mating
connector.
3
4
Use the two screws on the card to secure it into place.
To install a Campus-RS Line Unit to work with the interface card, and to
connect the Campus system to an HDSL line, see the Campus-RS Line
Unit User Manual.
CONNECT THE ETHERNET LINE
The 10BASE-T MDI port on the rear of the Campus-REX card connects the
Campus-REX to hubs, repeaters, or other routers.
Choosing the Cable
Use a straight-through cable (Category 3 or better) to connect the card to a
device with an MDI-X port. Use a cross-over cable (Category 3 or better) to
connect the Campus-REX to a device with an MDI port.
The following table lists the 10BASE-T interface data signals for both MDI
and MDI-X port configurations.
MDI Pin (a) MDI-X Pin
Signal
Description
1
2
3
4
5
6
7
8
3
6
1
4
5
2
7
8
TD+
TD-
Transmit Data (+)
Transmit Data (-)
Receive Data (+)
RD+
RD-
Receive Data (-)
(a) A 10BASE-T port on a PC is always configured as an
MDI port.
2-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Campus-REX RS Interface Card
The following figures illustrate the signals for straight-through and
cross-over cables.
Campus-REX RS Interface Card User Manual
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Campus-REX RS Interface Card
Connecting the Cable
To connect the 10BASE-T cable to the Campus-REX RS Interface Card:
1
Plug one end of the Category 3 cable into the 10BASE-T MDI connector
on the rear of the Campus-REX.
Campus-RS Desktop Unit chassis
Local equipment
(Ethernet)
6
3
1
ETHERNET BRIDGE
10BASE-T MDI port
10BASE-T port
C
F
G
BaseT
LIN
K
120
or 220
V
A
C@60Hz
V
A
.2A MCa@x50Hz
Category 3 cable
2
Connect the other end of the cable to your local equipment (repeater, PC,
or other 802.3 device).
2-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Campus-REX RS Interface Card
POWER UP AND CHECK THE ETHERNET LINE
1
Verify that the power cord is connected to the Desktop Unit or to the
external power source.
2
Do one of the following:
•
If the Campus-REX is installed in a Desktop Unit, press the power
button on the back of the Desktop Unit.
•
If the Campus-REX is installed in a Campus-Star, continue with
Step 3.
3
Verify that the Link LED on the Campus-REX card is green. This
indicates that the 10BASE-T connection is operating correctly. If the
Link LED does not light green, check the 10BASE-T cabling
configuration.
Campus-REX RS Interface Card User Manual
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Campus-REX RS Interface Card
2-8
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
SET UP THE
CAMPUS-REX SYSTEM
3
There are four sets of configuration options that must be set correctly for the
Campus-REX to operate. With the default settings, the Campus-REX is set to
operate:
•
•
•
with the HDSL Operating Mode set to Standard Mode
with the Standard Mode HDSL Rate set to T1
as a bridge, with the encapsulation format set to HDLC and Spanning
Tree protocol disabled
•
with the Timing Source set to Internal
default settings for one or more of these options. If so, you can skip the
relevant section(s).
To Learn How to:
See Page:
Set Up an ASCII Terminal
3-2
3-7
Set the HDSL Operating Mode
Configure the Campus-REX as a Bridge or Router
Set the Timing Source
3-19
3-29
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-1
Set Up the Campus-REX System
SET UP AN ASCII TERMINAL
You can configure the Campus system through an ASCII terminal connected
to the Desktop Unit or Campus-Star in which the Campus-REX is installed.
The terminal provides access to some configuration options not available
through the LCD menus.
Depending on your immediate configuration plans, you may not need to set
up an ASCII terminal now. However, you need to set up a terminal if one of
the following applies:
•
•
you plan to use the Campus-REX as a router
you need to change the HDSL transmission rate and do not want to use
the LCD menus
•
•
you plan on setting additional configuration options at this time
you want to view performance statistics on the HDSL and 10BASE-T
interfaces
If none of these reasons apply to you, skip this section and proceed to “Set the
HDSL Operating Mode” on page 3-7.
3-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
Connecting the ASCII Terminal to the Campus Unit
To connect the Campus-REX RS Interface Card to an ASCII terminal:
1
2
Plug the console adapter into the standard 9-pin COM port on the ASCII
terminal and tighten the attached screws until they are snug. Skip this
step if the ASCII terminal provides an RJ-48 jack.
Plug one end of the console cable into the console adapter, then do one
of the following:
•
Plug the other end of the console cable into the console port on the
Desktop Unit.
Campus desktop chassis
ASCII terminal
9-pin COM
port
Console port
E
T
H
E
R
N
E
10BaTseT
B
R
I
D
G
E
LINK
120
or 220
V
A
C@60Hz
V
A
.2A MCa@x50Hz
Cable
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-3
Set Up the Campus-REX System
•
If the Campus-REX is installed in a Campus-Star, do one of the
following:
–
plug the other end of the console cable into the console port on
the front of the Line Unit.
Campus-Star chassis
C
M
U
-71
0
M
A
N
A
G
E
M
E
Console port
N
T
U
N
IT
P
O
W
E
R
S
L
O
T
A
L
A
R
ASCII terminal
M
S
M
M
AC
A
I
J
O
R
R
N
Cam
LIN
O
pus HR
O
E
UNIT
S
Campus HRS
LINE UNIT
R
E
S
Cam
E
T
HDSL
TEST
pus HRS
LINE UNIT
Cam
HDSL
TEST
pus HRS
POR
T
LINE UN
IT
Cam
pus HRS
HDSL
TEST
POR
T
LINE UNIT
Cam
HDSL
TEST
pus HRS
POR
T
LINE UNIT
9-pin COM
port
RS-232
CONSOLE
Cam
pus HR
HDSL
TEST
POR
T
LINE UN
S
IT
RS-232
CONSOLE
C
am
pus HRS
LINE
HDSL
TEST
POR
T
UNIT
RS-232
CONSOLE
Cam
pus HR
HDSL
TEST
POR
T
LINE
U
S
NIT
RS-232
CONSOLE
HDSL
TEST
POR
T
RS-232
CONSOLE
HDSL
TEST
POR
T
RS-232
CONSOLE
POR
T
RS-232
CONSOLE
RS-232
CONSOLE
RS-232
CONSOLE
Cable
–
use an adapter to plug the other end of the console cable into the
console port of the Campus Management Unit (CMU) on the
Campus-Star, as described in the Campus-Star User Manual.
3-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
3
Configure the ASCII terminal to the following communications settings:
•
•
•
•
•
9600 baud
no parity
8 data bits
1 stop bit
no hardware flow control
Logging Onto the Terminal
1
Press the SPACEBAR on the ASCII terminal keyboard several times until
the baud rate is established and the Login Password screen displays on
the terminal monitor.
May 3,1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:12:59
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
LOGIN PASSWORD >
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-5
Set Up the Campus-REX System
2
Press ENTER to log on. If you have set a password, type your password
then press ENTER . The Main Menu displays.
May 3 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:14:02
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
MAIN MENU
1) SYSTEM STATUS
2) DATA PORT SETTINGS
3) SYSTEM SETTINGS
4) DIAGNOSTICS
5) REMOTE LOGON
(L)ogout
ENTER CHOICE>
If the system does not respond when you attempt to log on, ensure that
hardware flow control is turned off on the ASCII terminal.
3-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
SET THE HDSL OPERATING MODE
The Campus-REX is set to operate in Standard Mode with a T1 (1.544 Mbps)
HDSL Rate. This is compatible with other Campus-RS products and with
Campus-T1 Desktop Units and Line Units. If this is the desired setting for
on page 3-19. Otherwise, follow the steps in this section to adjust the HDSL
transmission rate.
There are two ways to configure the HDSL line:
•
•
To use the LCD menus, see “Using the LCD,” below.
To use an ASCII Terminal, see “Using an ASCII Terminal” on
page 3-11.
Changes to the HDSL operating mode or transmission rate are
not automatically made to the remote unit. These changes
must be made at both the local and remote units for the HDSL
link to be re-established. If the remote unit is not easily
accessible, you can follow the instructions in “Logging Onto
a Remote Campus Unit” on page 5-3 to use an ASCII terminal
to perform a remote logon (if an HDSL link is up) and make the
desired change. When you change the HDSL settings for the
remote unit, the HDSL link is lost; it is re-established when
you make the identical change(s) to the local unit.
Campus-REX RS Interface Card User Manual
3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
Using the LCD
The steps in this section use the menu buttons and LCD on the front of the
Desktop Unit or the Campus-Star Campus Management Unit (CMU). The
figure below shows the LCD and menu buttons on the Campus-RS Desktop
Unit. See the Campus-Star User Manual for the location of the LCD and
menu buttons on the CMU. For a complete description of how to use the menu
buttons and LCD, see “Navigating the LCD Menus” on page 4-2.
LCD
Menu buttons
CAMPUS RS
HDSL
Test
Next
Escape
Enter
Port
To set the HDSL Transmission Rate:
1
2
3
4
Press Escape until Campus RS I/F: REXdisplays.
Press Next. HDSL LINK CONFIG & STATUSdisplays.
Press Enter. OPERATING MODEdisplays.
Continue with one of the following sections, depending on whether you
are using Standard Mode (page 3-8), Extended Mode (page 3-9), or
AutoSync Mode (page 3-10).
Standard HDSL Mode
This section continues from Step 4 in the previous section to set a Standard
Mode HDSL Rate.
Choose from the following settings:
•
•
•
T1
E1
768
3-8
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
1
2
If the Operating Mode is set to Standard Mode, proceed to Step 3.
Otherwise, press Enter.
Operating Mode changes to Standard.
3
4
Press Next until HDSL RATEdisplays, then press Enter.
Press Next until the desired HDSL transmission rate displays, then
press Enter.
To continue setting up the system, proceed to “Configure the Campus-REX
as a Bridge or Router” on page 3-19.
Extended HDSL Mode
This section continues from Step 4 in “Using the LCD” on page 3-8 to set the
Extended Mode parameters.
To set an Extended Mode HDSL Rate, you must:
•
Set the Extended Mode Loop Configuration to 1 Loop or 2 Loop,
depending on the physical layout of your HDSL network.
•
Set the Extended Mode HDSL Rate to one of the options determined by
the Extended Mode Loop Configuration:
–
1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments.
–
2 Loop HDSL Rate settings are between 256 kbps and 2.304 Mbps,
in 128 kbps increments.
1
2
With the LCD displaying OPERATING MODE, press the Enter button.
Press Next until EXTENDEDdisplays, then press Enter. The LCD
displays OPERATING MODE.
3
4
5
Press Next two times. LOOP MODEdisplays.
Press Enter.
Press Next until the desired Loop Mode setting displays, then press
Enter. The LCD displays LOOP MODE.
Campus-REX RS Interface Card User Manual
3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
6
7
8
Press Next. HDSL RATEdisplays.
Press Enter.
Press Next until the desired HDSL transmission rate displays, then
press Enter.
To continue setting up the system, proceed to “Configure the Campus-REX
as a Bridge or Router” on page 3-19.
AutoSync HDSL Mode
This section continues from Step 4 in “Using the LCD” on page 3-8 to set the
Extended Mode parameters.
To configure AutoSync Mode, you must:
•
•
Set the Transceiver Mode to Master or Slave.
If the Transceiver Mode is set to Master, set the HDSL Loop Mode to
1 Loop or 2 Loop, depending on the physical layout of your HDSL
network.
•
If the Transceiver Mode is set to Master, set the HDSL Rate to one of the
options determined by the HDSL Loop Mode:
–
1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments.
–
in 128 kbps increments.
1
2
With the LCD displaying OPERATING MODE, press Enter.
Press Next until AUTOSYNCdisplays, then press Enter.
OPERATING MODEdisplays. If you are configuring an AutoSync slave
system, skip the remainder of this section and proceed to “Configure the
Campus-REX as a Bridge or Router” on page 3-19. For an AutoSync
master system, continue with the remaining steps.
3
4
5
Press Next until XCVR MODEdisplays.
Press Enter.
Press Next until the MASTER displays, then press Enter. XCVR MODE
displays.
6
Press Next until LOOP MODEdisplays.
3-10
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
7
8
Press Enter.
Press Next until the desired Loop Mode setting displays, then press
Enter. LOOP MODEdisplays.
9
Press Next. HDSL RATEdisplays.
10 Press Enter.
11 Press Next until the desired HDSL transmission rate displays, then
press Enter.
To continue setting up the system, proceed to “Configure the Campus-REX
as a Bridge or Router” on page 3-19.
Using an ASCII Terminal
The steps in this section use an ASCII terminal. To set the HDSL
transmission rate:
1
Follow the steps in “Set Up an ASCII Terminal” on page 3-2 to connect
the ASCII terminal and log on to the Main Menu.
2
From the Main Menu, type 3 then press ENTER . The System Settings
Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:41
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM SETTINGS MENU
1) SYSTEM PARAMETERS
2) HDSL PARAMETERS
(R)eturn
ENTER CHOICE>
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
3-11
Set Up the Campus-REX System
3
Type 2 then press ENTER . The Standard Mode HDSL Parameters or
Extended Mode HDSL Parameters menu displays. While the illustrations
in this section show the Standard Mode HDSL Parameters menu, the
instructions are the same for both menus.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
00:27:03
Local Unit ID: Campus REX Unit #34
Remote Unit ID: Campus REX Unit #12
Circuit ID:
Local I/F: REX
Remote I/F: REX
STANDARD MODE HDSL PARAMETERS
1) HDSL Operating Mode: Standard
(Standard, Extended)
(Master, Slave, Auto)
(768, T1, E1)
2) Transceiver Mode:
3) HDSL Rate:
Auto
T1
Changes will not be effective until this menu is exited!
(R)eturn (M)ain Menu
ENTER CHOICE>
4
Continue with one of the following sections, depending on whether you
are using Standard Mode (page 3-12), Extended Mode (page 3-13), or
AutoSync Mode (page 3-16).
Standard HDSL Mode
This section continues from Step 4 in the previous section to set a Standard
HDSL mode.
Choose from the following settings:
•
•
•
T1
E1
768
3-12
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
To set a Standard HDSL Mode:
1
2
3
4
If the HDSL Operating Mode is set to Extended Mode, type 1 then press
ENTER .
From the HDSL Parameters menu, type 3 then press ENTER . The
HDSL Rate option changes to the next setting.
Repeat the previous step until the HDSL Rate option is set to the desired
setting.
made.
To continue setting up the system, proceed to “Configure the Campus-REX
as a Bridge or Router” on page 3-19.
Extended HDSL Mode
This section continues from Step 4 on page 3-12 to set an extended HDSL
mode.
To set a Standard Mode HDSL Rate, you choose from the list of predefined
rates. To set an Extended Mode HDSL Rate, you must:
•
Set the Extended Mode Loop Configuration to 1 Loop or 2 Loop,
depending on the physical layout of your HDSL network.
•
Set the Extended Mode HDSL Rate to one of the options determined by
the Extended Mode Loop Configuration:
–
1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments.
–
2 Loop HDSL Rate settings are between 256 kbps and 2.304 Mbps,
in 128 kbps increments.
Campus-REX RS Interface Card User Manual
3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
1
From the HDSL Parameters menu, type 1 then press ENTER . The
HDSL Operating Mode options changes from Standard Mode to
Extended Mode.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:19:32
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
EXTENDED MODE HDSL PARAMETERS
1) HDSL OPERATING MODE: Extended
(Standard, Extended)
(Master, Slave, Auto)
(1 Loop, 2 Loops)
2) TRANSCEIVER MODE:
Auto
3) HDSL LOOP MODE:
4) HDSL RATE:
2 Loops
256
*Note:
1 Loop = single loop, full duplex
2 Loops = two loops, full duplex
Changes will not be effective until this menu is exited!
(R)eturn (M)ain Menu
ENTER CHOICE>
2
3
To change the HDSL Loop Mode, type 3 then press ENTER . Repeat this
step until the desired HDSL Loop Mode setting displays.
Type 4 then press ENTER . The Select HDSL Rate menu displays.
3-14
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
Mar 10, 2001
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:19:32
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SELECT HDSL HIGH RATE
Current HDSL Rate: 256
Current Loop Mode: 2 Loops
1) N/A
7) 896 kbps
8) 1024 kbps
9) 1152 kbps
10) 1280 kbps
11) 1408 kbps
12) 1536 kbps
13) 1664 kbps
2) 256 kbps
3) 384 kbps
4) 512 kbps
5) 640 kbps
6) 768 kbps
14) 1792 kbps
15) 1920 kbps
16) 2048 kbps
17) 2176 kbps
18) 2304 kbps
(R)eturn (M)ain Menu
ENTER CHOICE>
4
5
Type the number for the desired HDSL transmission rate then press
ENTER . The terminal returns to the HDSL Parameters menu and displays
the new HDSL Rate.
Type R to exit the menu, then confirm any HDSL changes you have
made.
To continue setting up the system, proceed to “Configure the Campus-REX
as a Bridge or Router” on page 3-19.
Campus-REX RS Interface Card User Manual
3-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
AutoSync HDSL Mode
This section continues from Step 4 on page 3-12 to set up AutoSync HDSL
mode.
To configure AutoSync Mode, you must:
•
•
Set the Transceiver Mode to Master or Slave.
If the Transceiver Mode is set to Master, set the HDSL Loop Mode to
1 Loop or 2 Loop, depending on the physical layout of your HDSL
network.
•
If the Transceiver Mode is set to Master, set the HDSL Rate to one of the
options determined by the HDSL Loop Mode:
–
1 Loop HDSL Rate settings are between 128 kbps and 1.152 Mbps,
in 64 kbps increments.
–
2 Loop HDSL Rate settings are between 256 kbps and 2.048 Mbps,
in 128 kbps increments.
1
From the Standard Mode HDSL Parameters menu, type 1 then press
ENTER until the HDSL Operating Mode options changes to AutoSync
Mode. If the terminal is already set to the AutoSync Mode HDSL
Parameters menu, skip this step.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:19:32
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
AUTOSYNC MODE HDSL PARAMETERS
1) HDSL Operating Mode: Autosync
2) Transceiver Mode: Slave
(Standard, Extended, Autosync)
(Master, Slave)
HDSL Loop Mode:
HDSL Rate:
Note:
Remote Unit must be set as Autosync, Master.
Changes will not be effective until this menu is exited!
(R)eturn (M)ain Menu
ENTER CHOICE>
3-16
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
2
To change the Transceiver Mode, type then press ENTER . The
Transceiver Mode changes to the next available setting.
Continue with the following steps if the Transceiver Mode is set to
Master. If you set the Transceiver Mode to Slave, you cannot configure
the remaining options on this menu. These settings will be acquired from
the master unit when the HDSL link is established.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:19:32
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
AUTOSYNC MODE HDSL PARAMETERS
1) HDSL Operating Mode: Autosync
(Standard, Extended, Autosync)
(Master, Slave)
2) Transceiver Mode:
Master
2 Loops
256
3) HDSL Loop Mode:
4) HDSL Rate:
(1 Loop, 2 Loops)*
*Note:
1 Loop = single loop, full duplex
2 Loops = two loops, full duplex
Remote Unit must be set as Autosync, Slave.
Changes will not be effective until this menu is exited!
(R)eturn (M)ain Menu
ENTER CHOICE>
3
4
To change the HDSL Loop Mode, type 3 then press ENTER . The HDSL
Loop Mode changes to the next available setting.
Type 4 then press ENTER . The Select HDSL High Rate (if the HDSL
Loop Mode is set to 1 Loop) or Select HDSL Low Rate (if the HDSL
Loop Mode is set to 2 Loops) menu displays.
Campus-REX RS Interface Card User Manual
3-17
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:19:32
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SELECT HDSL HIGH RATE
Current HDSL Rate: 256
Current Loop Mode: 2 Loops
1) N/A
13) 1664 kbps
14) 1792 kbps
15) 1920 kbps
16) 2048 kbps
2) 256 kbps
3) 384 kbps
4) 512 kbps
5) 640 kbps
6) 768 kbps
7) 896 kbps
8) 1024 kbps
9) 1152 kbps
10) 1280 kbps
11) 1408 kbps
12) 1536 kbps
(R)eturn (M)ain Menu
ENTER CHOICE>
5
Type the number for the desired HDSL transmission rate then press
ENTER . The terminal returns to the HDSL Parameters menu and displays
the new HDSL Rate.
To continue setting up the system, proceed to the next section.
3-18
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
CONFIGURE THE CAMPUS-REX AS A BRIDGE
OR ROUTER
The Campus-REX can be configured to operate in one of two ways:
•
as a bridge to forward 802.3 frames using MAC addresses (see
“Configuring as a Bridge”)
•
as a router to forward IP packets based on a static routing table (see
“Configuring as a Router” on page 3-23)
For an overview of bridges, routers, and other network management
concepts, see “Internetworking and Management Overview” on page 7-1.
Configuring as a Bridge
Two configuration options, described in “MAC-Level Bridging and
Spanning Tree Protocol” on page 7-2, define how the Campus-REX operates
as a bridge. These options:
•
set Encapsulation to HDLC or PPP:
–
–
Use HDLC for most applications.
Use PPP when the remote unit includes a synchronous interface
card, such as a V.35 card.
•
enable or disable Spanning Tree
This section describes how to configure the bridge options for the
Campus-REX.
Campus-REX RS Interface Card User Manual
3-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
From the LCD
The steps in this section use the menu buttons and LCD on the front of the
Desktop Unit or the Campus-Star CMU.
If the Campus-REX has been set as a router, you must use an
ASCII terminal if you want to change it back to a bridge. See
“From an ASCII Terminal” on page 3-21.
To configure the Bridge options:
1
2
Press Escape until Campus RS I/F: REXdisplays.
Press Next twice, until DATA PORT CONFIG & STATUSdisplays,
then press Enter. The LCD displays CONFIGURE REX SETTINGS.
3
4
5
6
Press Enter. The LCD displays REX MODE BRIDGE MODE.
Press Next twice. ENCAPSULATIONdisplays.
Press Enter. The LCD displays the current Encapsulation setting.
Press Next until the desired Encapsulation setting displays, then
press Enter.
7
8
9
Press Next. SPANNING TREEdisplays.
Press Enter. The LCD displays the current Spanning Tree setting.
Press Next until the desired Spanning Tree setting displays, then
press Enter.
10 Press Next. Press Enter to reset interfacedisplays.
11 Press Enter. The Campus-REX restarts with the changes in effect.
3-20
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
From an ASCII Terminal
1
If you have not already done so, follow the steps in “Set Up an ASCII
Terminal” on page 3-2 to connect the ASCII terminal and log on to the
Main Menu.
2
From the Main Menu, type 2 then press ENTER . The Data Port Settings
menu displays.
On the Data Port Settings menu, option 4 to Reset the
Interface Card displays only when you have changed
configuration that requires you to save to NVRAM and then
reset the modem to effect the change.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:16:44
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DATA PORT SETTINGS
00:20:A7:21:2F:6B
MAC ADDRESS:
10 BASE-T STATUS: Up
1) BRIDGE/ROUTER CONFIGURATION
2) SNMP CONFIGURATION
3) WRITE NVRAM
4) RESET INTERFACE CARD
WARNING: NVRAM must be written and interface card reset for any
configuration changes to take effect.
(R)eturn
ENTER CHOICE>
3
Type 1 then press ENTER . The Bridge/Router Configuration menu
displays.
Campus-REX RS Interface Card User Manual
3-21
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:17:00
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
BRIDGE/ROUTER CONFIGURATION
MODE SETTING 1) Bridge/Router Mode:
Bridge
HDLC
Internal
Disabled
(Bridge, Router)
(HDLC, PPP)
(Internal, HDSL)
(Disabled, Enabled)
2) Encapsulation:
3) Timing Source:
4) Spanning Tree:
5) Local IP Address:
6) Local Subnet Mask:
7) Default Router:
0.0.0.0
255.255.255.0
0.0.0.0
8) BOOT Mode:
Local
(Local, Network)
(R)eturn (M)ain Menu
ENTER CHOICE>
4
5
6
To change the packet encapsulation format, type 2 then press ENTER .
The Encapsulation option changes from HDLC to PPP.
To enable Spanning Tree, type 4 then press ENTER . The Spanning Tree
option changes from Disable to Enable.
Type 5 then press ENTER . The terminal prompts you to enter the local
IP address of the Campus-REX. This must be set for the Campus-REX
to respond to the application (SNMP) that uses the IP protocol.
7
8
Type the address, in decimal-dotted notation, then press ENTER . The
Bridge/Router Configuration menu displays the new address.
Type 6 then press ENTER . The terminal prompts you to enter the subnet
mask of the Campus-REX. This allows the Campus-REX to determine if
a host, such as an SNMP management station or trap receiver, is on the
same local subnet. If it is, the Campus-REX can send messages directly
to the host; if not, messages must be sent through a default router. This
must be set for the Campus-REX to respond to applications that use the
IP protocol.
9
Type the subnet mask, in decimal-dotted notation, then press ENTER .
The Bridge/Router Configuration menu displays the new subnet mask.
10 Type 7 then press ENTER . The terminal prompts you to enter the IP
address of the default router the Campus-REX uses to reach a host
(SNMP station or trap receiver) on another network.
3-22
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
11 Type the address, in decimal-dotted notation, then press ENTER .
12 Type R then press ENTER to return to the Data Port Settings menu.
13 Type 3 then press ENTER to write the new bridge configuration to
NVRAM.
14 If you are done making configuration changes, type 4 then press ENTER
to reset the Campus-REX and enable the changes. If you plan to continue
making configuration changes, wait until you have finished before
resetting the system.
Make sure you reset the interface card when you have finished
changing bridge/router configuration options. The changes
do not take effect until the system is reset.
Configuring as a Router
Several options, described in “Static IP Routing” on page 7-4, define how the
Campus-REX operates as a router. Use these options to:
•
•
enter the address of a default gateway router
set Encapsulation to HDLC or PPP:
–
–
Use HDLC for most applications.
Use PPP when the remote unit is a synchronous interface card, such
as a V.35 card.
•
•
enter up to three destination addresses, subnet masks and gateway
addresses into the IP Static Routing Table
enter the IP address and subnet mask for the Campus-REX
This section describes how to configure the Campus-REX as a router.
You can only configure the Campus-REX as a router through
an ASCII terminal. Router options are not available through
the LCD menus.
Campus-REX RS Interface Card User Manual
3-23
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
1
2
If you have not already done so, follow the steps in “Set Up an ASCII
Terminal” on page 3-2 to connect the ASCII terminal and log on to the
Main Menu.
From the Main Menu, type 2 then press ENTER . The Data Port Settings
menu displays.
On the Data Port Settings menu, option 4 to Reset the
Interface Card displays only when you have changed
configuration that requires you to save to NVRAM and then
reset the modem to effect the change.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:16:44
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DATA PORT SETTINGS
00:20:A7:21:2F:6B
MAC ADDRESS:
10 BASE-T STATUS: Up
1) BRIDGE/ROUTER CONFIGURATION
2) SNMP CONFIGURATION
3) WRITE NVRAM
4) RESET INTERFACE CARD
WARNING: NVRAM must be written and interface card reset for any
configuration changes to take effect.
(R)eturn
ENTER CHOICE>
3
Type 1 then press ENTER . The Bridge/Router Configuration menu
displays.
3-24
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:17:00
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
BRIDGE/ROUTER CONFIGURATION
MODE SETTING 1) Bridge/Router Mode:
Bridge
HDLC
(Bridge, Router)
(HDLC, PPP)
(Internal, HDSL)
(Disabled, Enabled)
2) Encapsulation:
3) Timing Source:
4) Spanning Tree:
5) Local IP Address:
6) Local Subnet Mask:
7) Default Router:
8) BOOT Mode:
Internal
Disabled
0.0.0.0
255.255.255.0
0.0.0.0
Local
(Local, Network)
(R)eturn (M)ain Menu
ENTER CHOICE>
4
If the Bridge/Router Mode is set to Bridge, type 1 then press ENTER .
The Bridge/Router Configuration menu displays the router options.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:17:19
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
BRIDGE/ROUTER CONFIGURATION
MODE SETTING 1) Bridge/Router Mode:
Router
HDLC
Internal
(Bridge, Router)
(HDLC, PPP)
(Internal, HDSL)
2) Encapsulation:
3) Timing Source:
LAN PORT
4) LAN IP Address:
5) LAN Subnet Mask:
6) Line IP Address:
7) Line Subnet Mask:
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
LINE PORT
DESTINATION
8) Default Router:
9) 0.0.0.0
10) 0.0.0.0
11) 0.0.0.0
SUBNET MASK
GATEWAY ADDRESS
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
IP STATIC
ROUTING
TABLE
0.0.0.0
0.0.0.0
0.0.0.0
(R)eturn (M)ain Menu
ENTER CHOICE>
5
To change the packet encapsulation format, type 2 then press ENTER .
The Encapsulation option changes from HDLC to PPP.
Campus-REX RS Interface Card User Manual
3-25
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
6
Type 8 then press ENTER . A prompt displays, asking you to enter the
default router IP address. This address defines the next hop default router
for the Campus-REX to use to route packets that have a destination
address that is not in the IP Static Routing Table.
7
8
Type the address, in decimal-dotted notation then press ENTER .
Continue with the following sections.
Entering Port Addresses
This section describes how to enter the port addresses for the Campus unit.
There are two port addresses:
•
The LAN Port IP address is the IP address for the 10BASE-T port on the
Campus-REX.
•
The Line Port IP address is the IP address for the HDSL port on the
Campus Desktop Unit or Campus-Star chassis. If the HDSL line
connects two Campus-REX units, this address is hidden from the rest of
the network. In this case, you can assign artificial parameters to the Line
Port, although the Line Port addresses must belong to the same IP subnet.
1
2
3
4
5
6
From the Bridge/Router Configuration menu, type 4 then press ENTER .
The terminal prompts you to enter the LAN IP Address.
Type the address, in decimal-dotted notation, then press ENTER . The
new address displays.
Type 5 then press ENTER . The terminal prompts you to enter the LAN
Subnet Mask.
Type the mask, in decimal-dotted notation, then press ENTER . The new
subnet mask displays.
Type 6 then press ENTER . The terminal prompts you to enter the Line
IP Address.
Type the address, in decimal-dotted notation, then press ENTER . The
new address displays.
3-26
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
7
8
9
Type 7 then press ENTER . The terminal prompts you to enter the Line
Subnet Mask.
Type the mask, in decimal-dotted notation, then press ENTER . The new
subnet mask displays.
Continue with the following section.
Setting Up the IP Static Routing Table
This section describes how to enter the IP static routing table for the Campus
unit. This table can contain up to four explicit routes and one default router.
Each route consists of the destination network, subnet mask, and next-hop
gateway. The default route does not have a configurable subnet mask, but
uses the mode associated with the LAN or LINE networks, as described in the
previous section.
Fill in as many routing table entries as are appropriate to your network. You
can also proceed to the next section and leave the IP static routing table blank.
The steps in this section assume that you started from the beginning of the
previous section.
1
From the Bridge/Router Configuration menu, type 9 then press ENTER .
The terminal prompts you to enter the destination address for the first
routing table entry.
2
Type the destination address, in decimal-dotted notation, then press
ENTER . The terminal prompts you to enter the subnet mask for the table
entry.
3
4
Type the mask, in decimal-dotted notation, then press ENTER . The
terminal prompts you to enter the gateway address for the table entry.
Type the gateway address, in decimal-dotted notation, then press
ENTER . The terminal displays the Bridge/Router Configuration menu
with the first entry of the routing table filled in.
Campus-REX RS Interface Card User Manual
3-27
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
5
6
Type 1 0 then press ENTER . The terminal prompts you to enter the
Repeat steps 2 through 4. The terminal displays the Bridge/Router
Configuration menu with the first two entries of the routing table filled
in.
7
8
9
Type 1 1 then press ENTER . The terminal prompts you to enter the
Destination address for the third routing table entry.
Repeat steps 2 through 4. The terminal displays the Bridge/Router
Configuration menu with the completed routing table.
Type R then press ENTER to return to the Data Port Settings menu.
10 Type 3 then press ENTER to write the new bridge configuration to
NVRAM.
11 If you are done making configuration changes, type 4 then press ENTER
to reset the Campus-REX and enable the changes. If you plan to continue
making configuration changes, wait until you have finished before
resetting the system.
Make sure you reset the interface card when you have finished
changing bridge/router configuration options. The changes
do not take effect until the system is reset.
3-28
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
SET THE TIMING SOURCE
The Timing Source option determines the source of circuit timing on the
HDSL link. There are two settings for the Timing Source option:
•
Internal: Sets the Campus unit to take its timing from an internal
oscillator. This is the default setting.
•
HDSL: Sets the Campus unit to take its timing from the HDSL link.
The proper setting of the Timing Source option depends upon the interface
card of the remote Campus unit:
•
If the Campus-REX is connected to a Campus unit with another
Campus-REX RS Interface Card, leave the Timing Source option set to
Internal. The Campus system will not operate properly if both units are
set to HDSL.
•
If the Campus-REX is connected to a Campus unit with a synchronous
interface card, such as a Fractional V.35 card, the timing source depends
on the setting of the Primary Timing Source option of the remote unit:
–
Set the Timing Source to HDSL if the remote unit is set to Internal
or Port.
–
Set the Timing Source to Internal if the remote unit is set to HDSL.
See the Campus-RS Fractional Interface Card User Manual for
information on the Primary Timing Source option.
•
If the Campus-REX is connected to a Campus unit with a Campus
CSU/DS-1 or CSU/DSX-1 interface card, leave the Timing Source
option set to Internal.
Campus-REX RS Interface Card User Manual
3-29
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
Using the LCD
To set the Timing Source from the LCD:
1
2
Press Escape until Campus RS I/F: REXdisplays.
Press Next twice, until DATA PORT CONFIG & STATUSdisplays,
then press Enter. The LCD displays CONFIGURE REX SETTINGS.
3
4
Press Enter. The LCD displays REX MODE.
Press Next until TIMING SOURCEdisplays, then press Enter. The
LCD displays the current Timing Source setting.
5
Press Next until the desired Timing Source setting displays, then press
Using an ASCII Terminal
To set the Timing Source from an ASCII terminal:
1
Connect the ASCII terminal and log on to the Main Menu. See “Set Up
an ASCII Terminal” on page 3-2 for instructions.
2
From the Main Menu, type 2 then press ENTER . The Data Port Settings
menu displays.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:16:44
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DATA PORT SETTINGS
00:20:A7:21:2F:6B
MAC ADDRESS:
10 BASE-T STATUS: Up
1) BRIDGE/ROUTER CONFIGURATION
2) SNMP CONFIGURATION
3) WRITE NVRAM
4) RESET INTERFACE CARD
WARNING: NVRAM must be written and interface card reset for any
configuration changes to take effect.
(R)eturn
ENTER CHOICE>
3-30
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
3
Type 1 then press ENTER . The Bridge/Router Configuration menu
displays.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:17:00
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
BRIDGE/ROUTER CONFIGURATION
MODE SETTING 1) Bridge/Router Mode:
Bridge
(Bridge, Router)
2) Encapsulation:
3) Timing Source:
4) Spanning Tree:
5) Local IP Address:
6) Local Subnet Mask:
7) Default Router:
8) BOOT Mode:
HDLC
(HDLC, PPP)
(Internal, HDSL)
(Disabled, Enabled)
Internal
Disabled
0.0.0.0
255.255.255.0
0.0.0.0
Local
(Local, Network)
(R)eturn (M)ain Menu
ENTER CHOICE>
4
5
Type 3 then press ENTER . The Timing Source option changes Internal
to HDSL.
Repeat the previous step until the Timing Source option is set to the
desired setting.
Campus-REX RS Interface Card User Manual
3-31
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Up the Campus-REX System
3-32
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURING
AND MONITORING
THROUGH THE LCD
4
You can configure the Campus-REX RS Interface Card and view system
Campus-RS Desktop Unit or a CMU installed in the Campus-Star chassis.
This chapter describes how to use the LCD to set the individual
configuration options.
For Information About:
See Page:
Navigating the LCD Menus
4-2
4-3
Restoring the System to Default Values
Configuring the Campus-REX as a Master or Slave Unit
Viewing and Configuring Alarms
Configuring Loopbacks
4-4
4-5
4-10
4-12
4-13
Viewing System Information
Viewing Status Information
You can also perform these functions through an ASCII terminal connected
to the Desktop Unit or a Campus-RS Line Unit installed in the Campus-Star.
To use an ASCII terminal to configure the system, see “Configuring with an
ASCII Terminal” on page 5-1. To view system and status information, see
“Monitoring with an ASCII Terminal” on page 6-1.
Campus-REX RS Interface Card User Manual
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
NAVIGATING THE LCD MENUS
Use the LCD and menu buttons on the Desktop Unit or CMU to navigate the
menus and configure the Campus-RS system. The illustration below shows
the LCD and menu buttons on the Desktop Unit. See the Campus-Star User
Manual for the location of the LCD and menu buttons on the CMU.
LCD
Menu buttons
CAMPUS RS
HDSL
Test
Next
Escape
Enter
Port
The following table describes how to use the menu buttons to move through
the menus and select items.
Button
Function
Next
Scrolls to the next LCD menu or option at the same level of the
menu structure
Enter
Selects the displayed LCD menu or option
Returns to the previous LCD menu selection
Escape
Instructions for setting individual configuration options are included with
each option. The basic procedure is:
1
2
3
4
5
6
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next until the desired menu name displays.
Press Enter to access the menu options.
Press Next until the desired option name displays.
Press Enter to access the settings for the option.
Press Next until the desired setting displays.
4-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
7
8
Press Enter to select and save the desired option.
If desired, press Escape several times to return to the top of the menu
structure (CAMPUS RS I/F: REX).
See “LCD Menu Reference” on page A-3 for an illustration of the
hierarchical structure of the LCD menus.
RESTORING THE SYSTEM TO DEFAULT VALUES
You can restore all of the configuration options to their factory default values.
This is an easy way to remove undesired configurations you may have set and
want to return to their former settings.
To return the system configuration options to their default values:
1
2
3
4
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Enter. S/W REVdisplays.
Press Next six times. Press ENTER to factory resetdisplays.
Press Enter. The system configuration options return to the
default values.
Some options, such as the HDSL Rate must be the same for
both the local and remote unit. Resetting the Campus unit
configuration values on one unit only may cause the HDSL
link to go down.
Campus-REX RS Interface Card User Manual
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
CONFIGURING THE CAMPUS-REX AS A MASTER
OR SLAVE UNIT
The Transceiver Mode option determines the hierarchy of the two Campus
units when attempting to establish an HDSL link. There are three settings:
Master, Slave and Auto. Master and Slave are available for all three HDSL
Operating Mode settings. Auto Mode is only available for Standard and
Extended Modes, and is not available for AutoSync Mode.
•
If a unit is set to Master, it initiates the HDSL link. The other Campus
unit must be set to Slave or Auto.
•
If a unit is set to Slave, it waits for the other Campus unit to initiate the
HDSL link. The other unit must be set to Master or Auto. Slave is the
default setting for AutoSync HDSL Mode.
•
If a unit is set to Auto, it automatically switches between Master and
Slave until an HDSL link is established. The setting of the other Campus
unit is irrelevant. Auto is the default setting for Standard and Extended
HDSL Modes.
Unless you have a compelling reason for doing otherwise,
leaving the Transceiver Mode option set to Auto is
recommended.
To change the Transceiver Mode:
1
2
3
4
5
6
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next. HDSL LINK CONFIG & STATUSdisplays.
Press Enter. OPERATING MODEdisplays.
Press Next. XCVR MODEdisplays.
Press Enter.
Press Next to scroll through the Transceiver Mode options until the
desired setting displays.
7
Press Enter to select the displayed setting. XCVR MODEdisplays.
4-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
VIEWING AND CONFIGURING ALARMS
To determine if there is an active alarm condition:
1
2
3
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next three times. ALARM CONFIG & STATUSdisplays.
Press Enter. The LCD displays the current alarm status. There are three
indicators that can appear under CURRENT ALARMS:
• HDSLindicates an HDSL alarm
• LOCindicates a local alarm
• REMindicates a remote alarm
If a specific indicator does not display, there is no alarm in that area of
the system.
The following sections describe how to view specific alarm information for
the HDSL, local, and remote ports, and how to configure thresholds for the
various alarms.
HDSL Alarms
This section describes how to view and configure alarms on the HDSL line.
Viewing Current Alarms
If the CURRENT ALARMSdisplay indicates an HDSL alarm, you can
determine the alarm type:
1
2
From the CURRENT ALARMSdisplay, press Next. HDSL LINK
ALARMS CONFIG & STATUSdisplays.
Press Enter. The current status of three alarms displays:
• LINKshows whether the HDSL link is on or off
• ESshows whether the errored seconds threshold has been exceeded
on the local unit, remote unit, or both
• MARGINshows whether the margin threshold has been exceeded on
the local unit, remote unit, or both
Campus-REX RS Interface Card User Manual
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
Configuring Alarm Thresholds
Alarm thresholds determine the level at which an alarm condition is reached.
There are two types of HDSL alarm thresholds:
•
Link ES threshold determines the number of errored seconds that must
occur to trigger an alarm. This threshold can be set to 17 or 170 errored
seconds. You can also disable this alarm.
•
Margin threshold determines the margin, in dB, that triggers an alarm.
This threshold can be set anywhere between 1 dB and 25 dB, in 1 dB
increments. You can also disable this alarm.
To set the alarm thresholds:
1
From the CURRENT ALARMSdisplay, press Next. HDSL LINK
ALARMSdisplays.
2
3
4
5
Press Enter. The current HDSL alarm status displays.
Press Next. HDSL ES THRESHLDdisplays.
Press Enter.
Press Next to scroll through the settings for the ES threshold until the
desired setting displays.
6
Press the Enter button to select the desired setting. HDSL ES
THRESHLDdisplays.
7
8
9
Press Next. MARGIN THRESHLDdisplays.
Press Enter.
Press Next to scroll through the settings for the margin threshold until the
desired setting displays.
10 Press Enter to select the desired setting. MARGIN THRESHLDdisplays.
4-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
Viewing 24-Hour HDSL Alarm History
You can view the number of HDSL alarm conditions that have occurred over
the past 24 hours. The LCD displays 24-hour information for the following
alarms:
•
•
•
•
local errored seconds (LOCAL ES)
remote errored seconds (REMOTE ES)
local unavailable seconds (LOCAL UAS)
remote unavailable seconds (REMOTE UAS)
You may also view the time when the counter was last cleared and clear the
counter.
To view the HDSL alarm history:
1
2
3
4
5
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next. HDSL LINK CONFIG & STATUSdisplays.
Press Enter, then press Next until PERFORMANCE STATUSdisplays.
Press Enter, then press Next to scroll through the alarm history displays.
To reset the counter, press Next until Press ENTER to clear
error cntsdisplays, then press Enter.
AutoSync Alarms
The system generates an AutoSync alarm if the HDSL Operating Mode is set
to AutoSync and an HDSL connection cannot be established in AutoSync
Mode. This alarm is generated even if the HDSL link is eventually established
through Fallback Mode. This section describes how to view and configure
this alarm.
Campus-REX RS Interface Card User Manual
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
Viewing Current Alarms
1
From the CURRENT ALARMSdisplay, press Next until
HDSL LINK ALARMSdisplays.
2
3
4
Press Enter until the current HDSL alarm status displays.
Press Next until AUTOSYNC:displays.
If the AutoSync alarm is on or acknowledged, press Enter for more
information.
Configuring the Alarm
1
From the CURRENT ALARMSdisplay, press Next until
HDSL LINK ALARMSdisplays.
2
3
4
5
Press Enter until the current HDSL alarm status displays.
Press Next until AUTOSYNC CFG ALMdisplays.
Press Enter.
Press Next to scroll through the settings for the AutoSync alarm until the
desired setting displays.
6
Press Enter to select the desired setting. AUTOSYNC CFG ALM
displays.
Local Alarms
Loss of Signal (LOS) alarms can occur on the local unit. This section
describes how to view and configure this alarm.
Viewing Current Alarms
If the CURRENT ALARMSdisplay indicates a local alarm, you can determine
the alarm type:
1
2
From the CURRENT ALARMSdisplay, press Next twice. LOCAL I/F
ALARMS CONFIG & STATUSdisplays.
Press Enter. The current status of the local alarm displays.
4-8
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
Configuring the Alarm
To enable or disable the local Loss of Signal alarm:
1
From the CURRENT ALARMSdisplay, press Next twice. LOCAL I/F
ALARMS CONFIG & STATUSdisplays.
2
3
4
5
6
Press Enter. The current status of the local alarm displays.
Press Next. LOC LOSS OF SIG ALMdisplays.
Press Enter.
Press Next to scroll through the settings for the alarm.
Press Enter to select the desired setting. LOC LOSS OF SIG ALM
displays.
Remote Alarms
Loss of Signal (LOS) alarms can occur on the remote unit. This section
describes how to view and configure this alarm.
Viewing Current Alarms
If the CURRENT ALARMSdisplay indicates a remote alarm, you can
determine the alarm type:
1
2
From the CURRENT ALARMSdisplay, press Nextthree times. RMT I/F
ALARMS CONFIG & STATUS displays.
Press Enter. The current status of the remote alarm displays.
Campus-REX RS Interface Card User Manual
4-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
Configuring the Alarm
To enable or disable the remote Loss of Signal alarm:
1
From the CURRENT ALARMSdisplay, press Nextthree times. RMT I/F
ALARMSdisplays.
2
3
4
5
6
Press Enter. The current status of the remote alarm displays.
Press Next. LOSS OF SIG ALMdisplays.
Press Enter.
Press Next to scroll through the settings for the alarm.
Press Enter to select the desired setting. RMT LOSS OF SIG ALM
displays.
CONFIGURING LOOPBACKS
Loopbacks provide a way to test the data communication path between the
Campus unit, the remote unit, and the remote host equipment. The
Campus-REX supports two types of loopbacks:
•
Local to Remote loopbacks test the remote data port, the data path inside
the remote Campus unit, the HDSL line, the HDSL transceivers of both
units, and most of the internal data path inside the local unit. This
loopback does not test the local data port drivers and receivers.
•
Remote to Remote loopbacks test the remote data port and a small
portion of the remote interface card.
If both the local and remote units have a Campus-REX
interface card, no loopbacks are supported.
Once a loopback condition has been initiated, it remains in effect until
cleared. You may also set a loopback timeout to clear the loopback
automatically after a set period of time has elapsed.
4-10
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
You manage loopbacks through the DIAGNOSTICSmenu:
1
2
3
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next four times. DIAGNOSTICSdisplays.
Press Enter. LOOPBACK MODEdisplays.
The following sections describe how to initiate and clear loopbacks, and to
set a loopback timeout.
Initiating a Loopback
To initiate a loopback condition:
1
2
From the LOOPBACK MODEdisplay, press Enter.
Press Next to scroll through the loopback options until the desired
loopback condition displays.
3
Press Enter to initiate the loopback. LOOPBACK MODEdisplays.
Clearing a Loopback
To clear a loopback condition:
1
2
3
From the LOOPBACK MODEdisplay, press Enter.
Press Next to scroll through the loopback options until NONEdisplays.
Press Enter to clear the loopback. LOOPBACK MODEdisplays.
Campus-REX RS Interface Card User Manual
4-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
Setting the Loopback Timeout
The loopback timeout determines the amount of time before a loopback clears
automatically. To set a loopback timeout:
1
From the LOOPBACK MODEdisplay, press Next. LOOPBACK
TIMEOUTdisplays.
2
3
Press Enter to access the loopback timeout options.
Press Next to scroll through the options until the desired setting appears.
If you set the loopback timeout to NONE, loopbacks run until
you clear them manually or turn the unit off.
4
Press Enter to select the option and return to the LOOPBACK TIMEOUT
display.
VIEWING SYSTEM INFORMATION
Through the LCD menu you can view the following product information
(with the option name in parentheses):
•
•
•
•
•
•
firmware version and PROM checksum (S/W REVand S/W CKSUM)
hardware configuration information (H/W CONFIG)
local unit ID (LOCAL UNIT ID)
remote unit ID (REMOTE UNIT ID)
remote interface card type (REMOTE I/F)
circuit ID (CIRCUIT ID)
You cannot change any of this information through the LCD. Use an ASCII
terminal to set the local and remote unit IDs, and the circuit ID. See “Entering
System Information” on page 5-17.
4-12
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
To view the system information:
1
2
3
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Enter to view the firmware version and PROM checksum.
Press Next to scroll through the remaining options.
VIEWING STATUS INFORMATION
The LCD provides access to the following status information:
•
•
•
Ethernet information, such as the MAC address and 10BASE-T status
Current HDSL margin
Frame statistics on the Ethernet and HDSL ports
Ethernet Information
You can view the following information about the Ethernet port:
•
•
MAC address
current 10BASE-T status
To view Ethernet information:
1
2
3
4
5
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next twice. DATA PORT CONFIG & STATUSdisplays.
Press Enter. CONFIGURE REX SETTINGSdisplays.
Press Next to view the MAC ADDRESS.
Press Next again to view the current status of the 10BASE-T port.
Campus-REX RS Interface Card User Manual
4-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
HDSL Margin
You can view the current HDSL loop margin values, measured in dB, for the
local and remote HDSL loop. The listed values represent the margin relative
to a signal-to-noise ratio required for a Bit Error Rate (BER) of 10-7. A margin
value greater than zero indicates a performance of better than 10-7. The
system provides a minimum margin of 6 dB, which translates to a
performance of 10-10 BER or better.
To view the HDSL margin:
1
2
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next. HDSL LINK CONFIG & STATUSdisplays then
press Enter.
3
Press Next until MARGINdisplays.
Port Statistics
You can view the following statistics for the Ethernet and HDSL ports:
•
•
•
number of frames correctly received (IN)
number of frames correctly transmitted (OUT)
number of frames dropped due to an overflow of the input or output
buffer on the port (DSCRD)
•
number of frames received in error from both the input and output
buffers, such as CRC errors, alignment errors, and dribbling hit errors
(ERR)
To view the port statistics:
1
2
3
4
5
Press Escape until CAMPUS RS I/F: REXdisplays.
Press Next four times. DIAGNOSTICSdisplays.
Press Enter. LOOPBACK MODEdisplays.
Press Next two times. REX STATISTICSdisplays.
Press Enter. ETHERNET PORT FRAMESdisplays.
4-14
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
6
7
8
Press Next until the desired port displays, then press Enter.
Press Next to scroll through the statistics for the selected port.
To clear the counters, press Next until Press ENTER to clear
statisticsdisplays, then press Enter.
9
When you have finished, press Escape to return to REX STATISTICS.
Campus-REX RS Interface Card User Manual
4-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring and Monitoring through the LCD
4-16
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
CONFIGURING WITH AN
ASCII TERMINAL
configure Campus system options and generate system reports. The ASCII
terminal connects to the console port on the Campus-RS Desktop Unit or on
the Campus-RS Line Unit installed in the Campus-Star chassis.
This chapter describes how to use an ASCII terminal to set the individual
page 6-1.
For Information About:
Setting Up and Logging On to an ASCII Terminal
Logging Onto a Remote Campus Unit
Logging Off of a Campus Unit
5-2
5-3
Using the Terminal Menus
5-4
Returning Configuration Options to Default Values
Configuring the Campus-REX for SNMP Management
Configuring Startup Parameters
5-5
5-10
5-12
5-15
5-17
5-20
5-24
Configuring the Campus-REX as a Master or Slave Unit
Configuring Alarms
Entering System Information
Configuring Loopbacks
Updating the Campus-REX Firmware
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5-1
Configuring with an ASCII Terminal
You can also use the LCD and menu buttons on the front of the Campus-RS
Desktop Unit or on the Campus Management Unit (CMU) on the
Campus-Star chassis. To do this, see “Configuring and Monitoring
Through the LCD” on page 4-1.
SETTING UP AND LOGGING ON TO AN
ASCII TERMINAL
See “Set Up an ASCII Terminal” on page 3-2 for complete information on
setting up and logging on to the ASCII terminal Main Menu.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:14:02
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
MAIN MENU
1) SYSTEM STATUS
2) DATA PORT SETTINGS
3) SYSTEM SETTINGS
4) DIAGNOSTICS
5) REMOTE LOGON
(L)ogout
ENTER CHOICE>
5-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
LOGGING ONTO A REMOTE CAMPUS UNIT
This section describes how to log on to a remote Campus unit.
1
Press the spacebar on the ASCII terminal keyboard several times until
the baud rate is established and the Login Password screen displays on
the terminal monitor.
2
3
Press ENTER to log on. If you have changed the password, type your
password then press ENTER . The Main Menu displays.
Press 5 then press ENTER .
The menu header changes to indicate the remote unit ID as the local unit,
and local unit ID as the remote. This shows that the terminal program is
physically connected to the local unit, but is configuring as if it were
connected to the remote unit. The prompt changes to REMOTE LOGON
PASSWORD.
If the remote unit is a Campus-REX, the screens and procedures on the
Remote Main Menu are identical to those on the Local Main Menu,
except the REMOTE LOGON option is unavailable. If the remote unit is
not a Campus-REX, the screens will be those for the remote interface
card. See the User Manual for the interface card for a description of the
screens and configuration options.
LOGGING OFF OF A CAMPUS UNIT
From the Main Menu, type Q then press ENTER to log off of the unit menus.
If the Main Menu is not the current menu, type R then press ENTER until the
Main Menu displays.
Campus-REX RS Interface Card User Manual
5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
USING THE TERMINAL MENUS
The bottom of each menu screen identifies all of the keys you can use on that
screen. Several keys operate identically on all of the menu screens:
•
•
To access menu items, type the number of the item then press ENTER .
Press ESC or type R then press ENTER to exit the current menu and
return to the previous one.
•
In menus more than one level below the Main Menu, type M then press
ENTER to return to the Main Menu.
There are two types of configuration options. One type lets you select the
desired value from a list of predefined values. The other type prompts you to
type in the required information.
To set an option from a list of predefined values:
1
Type the number of the option then press ENTER . The option setting
changes to the next value in the list and the screen redraws.
2
Repeat the first step until the option is set to the desired value.
To set an option that requires you to enter information:
1
Type the number of the option then press ENTER . The screen prompts
you for information.
2
Type the information, in the format requested then press ENTER .
See “ASCII Terminal Menu Reference” on page A-5 for an illustration of the
hierarchical structure of the ASCII terminal menus.
5-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
RETURNING CONFIGURATION OPTIONS TO
DEFAULT VALUES
You can restore all of the configuration options to their factory default values.
This is an easy way to remove undesired configurations you may have set and
want to return to their former settings.
To restore the system to its default configuration:
1
From the Main Menu, type 3 then press ENTER . The System Settings
Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:41
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM SETTINGS MENU
1) SYSTEM PARAMETERS
2) HDSL PARAMETERS
(R)eturn
ENTER CHOICE>
2
Type 1 then press ENTER . The System Parameters screen displays.
Campus-REX RS Interface Card User Manual
5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:50
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM PARAMETERS
1) Change System Time
2) Change System Date
3) Change Unit ID
4) Change Circuit ID
5) Change Password
6) HDSL ES Alarm Threshold:
Disabled
(Disabled, 17, 170)
7) HDSL Margin Alarm Threshold: Disabled
8) Autosync Configuration Alarm: Enabled
(Enabled, Disabled)
(Disabled, Enabled)
(Disabled, Enabled)
9) Local Data Port LOS Alarm:
10) Remote Data Port LOS Alarm:
Disabled
Disabled
11) RESET TO FACTORY DEFAULT
(R)eturn (M)ain Menu
ENTER CHOICE>
3
Type 1 1 then press ENTER .
The system restores the configuration options to their default values.
Some options, such as the HDSL Rate must be the same for
both the local and remote unit. Resetting the Campus unit
configuration values on one unit only, may cause the HDSL
link to go down.
CONFIGURING THE CAMPUS-REX FOR SNMP
MANAGEMENT
The SNMP protocol provides a way to configure the Campus-REX system
over the network. For more information about SNMP management, see
“SNMP” on page 7-11.
5-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
The following SNMP parameters must be set to manage the Campus-REX
over an SNMP network:
•
SNMP Read Only Comm String provides the authentication string used
for SNMP read-only operations
•
SNMP Read Write Comm String provides the authentication string used
for SNMP read-write operations
You can also set the Campus-REX to perform authentication error trap
generation. To enable this feature, do the following:
•
•
•
•
•
Set the Authentication Trap Status to Enabled or Disabled.
Enter the IP Address for the first Trap Receiver.
Enter a comm string for the first Trap Receiver.
Enter the IP Address for the second Trap Receiver.
Enter a comm string for the second Trap Receiver.
To configure the SNMP parameters:
1
From the Main Menu, type 2 then press ENTER . The Data Port Settings
menu displays.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:16:44
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DATA PORT SETTINGS
00:20:A7:21:2F:6B
MAC ADDRESS:
10 BASE-T STATUS: Up
1) BRIDGE/ROUTER CONFIGURATION
2) SNMP CONFIGURATION
3) WRITE NVRAM
4) RESET INTERFACE CARD
WARNING: NVRAM must be written and interface card reset for any
configuration changes to take effect.
(R)eturn
ENTER CHOICE>
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5-7
Configuring with an ASCII Terminal
2
Type 2 then press ENTER . The SNMP Configuration menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:03
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SNMP CONFIGURATION
1) SNMP Read Only Community String:
public
2) SNMP Read/Write Community String:
3) Authentication Trap Status:
4) Trap Receiver 1 IP Address:
5) Trap Receiver 1 Community String:
6) Trap Receiver 2 IP Address:
7) Trap Receiver 2 Community String:
private
Disabled
0.0.0.0
public
0.0.0.0
public
(Disabled, Enabled)
(R)eturn
ENTER CHOICE>
3
Continue with the following sections to enter the required parameters
and, if desired, enable authentication error trap generation.
Entering Required SNMP Parameters
To set the required parameters:
1
2
3
4
From the SNMP Configuration menu, type 1 then press ENTER . The
system prompts you to enter the Read Only Comm String.
Type Public, or another string of up to 32 characters then press ENTER .
The SNMP Configuration menu displays.
Type 2 then press ENTER . The system prompts you to enter the Read
Write Comm String.
Type Private, or another string of up to 32 characters as prompted then
press ENTER . The SNMP Configuration menu displays.
5-8
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
Enabling Authentication Error Trap Generation
To enable authentication error trap generation:
1
2
3
4
5
From the SNMP Configuration menu, type 3 then press ENTER . The
system enables authentication trap generation.
Type 4 then press ENTER . The system prompts you to enter the IP
address for the first trap receiver.
Type the IP address, in decimal-dotted notation, then press ENTER . The
SNMP Configuration menu displays.
Type 5 then press ENTER . The system prompts you to enter the
character string for the first trap receiver.
Type a string of up to 64 characters then press ENTER . The SNMP
Configuration menu displays. If you are only using one trap receiver, you
have finished setting up authentication error trap generation. Otherwise,
continue to set up the second trap receiver.
6
7
8
9
Type 6 then press ENTER . The system prompts you to enter the IP
address for the second trap receiver.
Type the IP address, in decimal-dotted notation, then press ENTER . The
SNMP Configuration menu displays.
Type 7 then press ENTER . The system prompts you to enter the
character string for the second trap receiver.
Type a string of up to 64 characters then press ENTER . The SNMP
Configuration menu displays.
Campus-REX RS Interface Card User Manual
5-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
CONFIGURING STARTUP PARAMETERS
The Campus-REX can take its startup information from its internal NVRAM
or from a network server. For more information about downloading startup
information from a network, see “Management Protocols” on page 7-11.
Set the Boot Mode option to one of the following:
•
Local sets the Campus-REX to receive its protocol and network
configuration from internal memory.
•
Network sets the Campus-REX to receive its startup data from a network
server.
Set the Boot Mode only when the Campus-REX is set as a
bridge. The Boot Mode setting has no effect when the
Campus-REX is in router mode.
1
From the Main Menu, type 2 then press ENTER . The Data Port Settings
menu displays.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:16:44
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DATA PORT SETTINGS
00:20:A7:21:2F:6B
MAC ADDRESS:
10 BASE-T STATUS: Up
1) BRIDGE/ROUTER CONFIGURATION
2) SNMP CONFIGURATION
3) WRITE NVRAM
4) RESET INTERFACE CARD
WARNING: NVRAM must be written and interface card reset for any
configuration changes to take effect.
(R)eturn
ENTER CHOICE>
5-10
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
2
Type 1 then press ENTER . The Bridge/Router Configuration menu
displays.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:17:00
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
BRIDGE/ROUTER CONFIGURATION
MODE SETTING 1) Bridge/Router Mode:
Bridge
(Bridge, Router)
2) Encapsulation:
3) Timing Source:
4) Spanning Tree:
5) Local IP Address:
HDLC
(HDLC, PPP)
(Internal, HDSL)
(Disabled, Enabled)
Internal
Disabled
0.0.0.0
6) Local Subnet Mask:
7) Default Router:
255.255.255.0
0.0.0.0
8) BOOT Mode:
Local
(Local, Network)
(R)eturn (M)ain Menu
ENTER CHOICE>
3
4
If the Bridge/Router Mode is set to Router, type 1 then press ENTER .
The Bridge/Router Configuration menu displays the bridge options.
To change the Boot Mode, type 8 then press ENTER . The Bridge/Router
Configuration menu displays the new Boot Mode.
Campus-REX RS Interface Card User Manual
5-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
CONFIGURING THE CAMPUS-REX AS A MASTER
OR SLAVE UNIT
The Transceiver Mode option determines the hierarchy of the two Campus
units when attempting to establish an HDSL link. There are three settings:
Master, Slave and Auto. Master and Slave are available for all three HDSL
Operating Mode settings. Auto Mode is only available for Standard and
Extended Modes, and is not available for AutoSync Mode.
•
If a unit is set to Master, it initiates the HDSL link. The other Campus
unit must be set to Slave or Auto.
•
If a unit is set to Slave, it waits for the other Campus unit to initiate the
HDSL link. The other unit must be set to Master or Auto. Slave is the
default setting for AutoSync HDSL Mode.
•
If a unit is set to Auto, it automatically switches between Master and
Slave until an HDSL link is established. The setting of the other Campus
unit is irrelevant. Auto is the default setting for Standard and Extended
HDSL Modes.
Unless you have an important reason for doing otherwise,
leaving the Transceiver Mode option set to Auto is
recommended.
5-12
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
To change the Transceiver Mode:
1
From the Main Menu, type 3 then press ENTER . The System Settings
Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:41
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM SETTINGS MENU
1) SYSTEM PARAMETERS
2) HDSL PARAMETERS
(R)eturn
ENTER CHOICE>
2
Type 2 then press ENTER . The Standard Mode HDSL Parameters menu
or Extended Mode HDSL Parameters menu displays. The following
illustration shows the Standard Mode HDSL Parameters menu, but the
instructions are identical if the HDSL Operating Mode is set to Extended
Mode.
Campus-REX RS Interface Card User Manual
5-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
00:27:03
Local Unit ID: Campus REX Unit #34
Remote Unit ID: Campus REX Unit #12
Circuit ID:
Local I/F: REX
Remote I/F: REX
STANDARD MODE HDSL PARAMETERS
1) HDSL Operating Mode: Standard
(Standard, Extended)
(Master, Slave, Auto)
(768, T1, E1)
2) Transceiver Mode:
3) HDSL Rate:
Auto
T1
Changes will not be effective until this menu is exited!
(R)eturn (M)ain Menu
ENTER CHOICE>
3
Type 2 then press ENTER . The HDSL Parameters menu displays the
new Transceiver Mode setting. Repeat this step until the desired setting
displays.
5-14
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
CONFIGURING ALARMS
You can configure four different alarm options:
•
•
•
•
HDSL ES Alarm Threshold determines the number of errored seconds
that must occur to trigger an alarm
HDSL Margin Alarm Threshold determines the margin, in dB, that
triggers an alarm
Alarm on Local I/F LOS lets you enable or disable the local Loss of
Signal alarm
Alarm on Remote I/F LOS lets you enable or disable the remote Loss of
Signal alarm
To configure the alarm options:
1
From the Main Menu, type 3 then press ENTER . The System Settings
Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:41
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM SETTINGS MENU
1) SYSTEM PARAMETERS
2) HDSL PARAMETERS
(R)eturn
ENTER CHOICE>
2
Type 1 then press ENTER . The System Parameters menu displays.
Campus-REX RS Interface Card User Manual
5-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:50
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM PARAMETERS
1) Change System Time
2) Change System Date
3) Change Unit ID
4) Change Circuit ID
5) Change Password
6) HDSL ES Alarm Threshold:
Disabled
(Disabled, 17, 170)
7) HDSL Margin Alarm Threshold: Disabled
8) Autosync Configuration Alarm: Enabled
(Enabled, Disabled)
(Disabled, Enabled)
(Disabled, Enabled)
9) Local Data Port LOS Alarm:
10) Remote Data Port LOS Alarm:
Disabled
Disabled
11) RESET TO FACTORY DEFAULT
(R)eturn (M)ain Menu
ENTER CHOICE>
3
To configure the HDSL ES Alarm Threshold, type 6 then press ENTER .
The System Parameters menu shows the new HDSL ES Alarm
Threshold setting. Repeat this step until the desired setting displays.
4
5
To configure the HDSL Margin Alarm Threshold, type 7 then press
ENTER .
Type the desired margin threshold value, or D to disable, then press
ENTER . The System Parameters menu shows the new HDSL Margin
Threshold setting. Repeat this step until the desired setting displays.
6
7
8
To enable or disable the AutoSync alarm, type 8 then press ENTER . The
System Parameters menu shows the new AutoSync alarm setting. Repeat
this step until the desired setting displays.
To enable or disable the local LOS alarm, type 9 then press ENTER . The
System Parameters menu shows the new Alarm on Local I/F LOS
setting. Repeat this step until the desired setting displays.
To enable or disable the remote LOS alarm, type 1 0 then press
ENTER . The System Parameters menu shows the new Alarm on Remote
I/F LOS setting. Repeat this step until the desired setting displays.
5-16
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
ENTERING SYSTEM INFORMATION
This section describes how to enter information about the system. This
information is not required for system operation, but can assist in
maintenance and troubleshooting tasks. Tasks describes in this section are:
•
•
•
setting the system time and date
setting a password
labeling the unit and circuit with unique identifiers
You perform all of these tasks from the System Parameters menu. To access
this menu:
1
From the Main Menu, type 3 then press ENTER . The System Settings
Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:41
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM SETTINGS MENU
1) SYSTEM PARAMETERS
2) HDSL PARAMETERS
(R)eturn
ENTER CHOICE>
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5-17
Configuring with an ASCII Terminal
2
Type 1 then press ENTER . The System Parameters menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:50
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM PARAMETERS
1) Change System Time
2) Change System Date
3) Change Unit ID
4) Change Circuit ID
5) Change Password
6) HDSL ES Alarm Threshold:
Disabled
(Disabled, 17, 170)
7) HDSL Margin Alarm Threshold: Disabled
8) Local Data Port LOS Alarm:
9) Remote Data Port LOS Alarm:
Disabled
Disabled
(Disabled, Enabled)
(Disabled, Enabled)
10) RESET TO FACTORY DEFAULT
(R)eturn (M)ain Menu
ENTER CHOICE>
3
Continue with the following sections to set the desired options.
Setting the Time and Date
The Campus unit uses the time and date to record system events, such as
alarms. To set the time and date:
1
From the System Parameters menu, type 1 then press ENTER . The
system prompts you to enter the time.
2
Type the correct hour, in 24-hour format, a colon (:), and the minute then
press ENTER . The system displays the System Parameters menu with the
correct time.
3
4
Type 2 then press ENTER . The system prompts you to enter the date.
Type the number of the day, the number of the month, and the four-digit
year, separated by slashes (/) then press ENTER . The system displays the
System Parameters menu with the correct date.
5-18
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
Setting a Password
A password prevents unauthorized access to Campus configuration options.
Once a password has been set, it must be entered to log on to the system.
Your password can be any combination of up to ten letters or numbers, but
the first character must be a letter. Passwords are case-sensitive.
To set a password:
1
From the System Parameters menu, type 5 then press ENTER . The
system prompts you to enter the existing password.
2
If a password has already been set, type the password then press ENTER .
If there is no password, just press ENTER . The system prompts you to
enter the new password.
If you did not enter the correct password, the system prompts you to enter
it again. If this happens, repeat the previous step.
3
4
Type the new password, up to ten characters then press ENTER . The
system prompts you to confirm the password.
Type the new password again then press ENTER . The system displays the
System Parameters menu.
the new password again. Return to Step 3.
If you forget your password and cannot log onto the
Campus-REX, use the LCD to restore the configuration
settings to their default values. This removes the password.
For more information, see “Restoring the System to Default
Values” on page 4-3.
Identifying the Unit and Circuit
The Campus system supports two different identifiers:
•
•
the Unit ID identifies the individual Campus unit
the Circuit ID identifies the individual HDSL circuit, and is the same for
both the local and remote units
Campus-REX RS Interface Card User Manual
5-19
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
To set or change these identifiers:
1
2
3
4
From the System Parameters menu, type 3 then press ENTER . The
system prompts you to enter the Unit ID.
Type a unique identifier for the unit, up to 64 characters then press
ENTER . The system displays the System Parameters menu.
Type 4 then press ENTER . The system prompts you to enter the
circuit ID.
Type a unique identifier for the circuit, up to 32 characters then press
ENTER . The system displays the System Parameters menu.
CONFIGURING LOOPBACKS
Loopbacks provide a way to test the data communication path between the
Campus unit, the remote unit, and the remote host equipment. Depending on
the remote unit, the Campus system supports the following types of
loopbacks:
If both the local and remote units have a Campus-REX RS
Interface Card, no loopbacks are supported.
•
•
The Local to Local loopback tests the local data port and a small portion
of the Campus-REX RS Interface Card.
The Local HDSL loopback tests the local data port and the entire data
path of the local Campus-REX RS Interface Card, including the local
HDSL transceiver. The data path in this loopback extends to the HDSL
line transformer, and causes the HDSL link to go down (a Link Alarm
occurs).
•
The Remote to Local loopback tests the local data port, the entire data
path inside the local Campus unit, the HDSL line, the HDSL transceivers
of both units, and most of the internal data path inside the remote unit.
5-20
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
•
•
The Remote to Remote loopback tests the remote data port.
The Local to Remote loopback tests the remote data port, the entire data
path inside the remote Campus unit, the HDSL line, the HDSL
transceivers of both units, and most of the internal data path inside the
local unit. This loopback does not test the local data port drivers and
receivers.
Once a loopback condition has been initiated, it remains in effect until
cleared. You may also set a loopback timeout to clear the loopback
automatically after a set period of time has elapsed.
All loopback options are accessed through the Loopback Settings menu. To
open this menu:
1
From the Main Menu, type 4 then press ENTER . The Diagnostics Menu
displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:29:35
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DIAGNOSTICS MENU
1) LOOPBACK SETTINGS MENU
2) DOWNLOAD MODE
(R)eturn
ENTER CHOICE>
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
5-21
Configuring with an ASCII Terminal
2
Type 1 then press ENTER . The Loopback Settings Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:29:44
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
LOOPBACK SETTINGS
ACTIVE LOOPBACK: None
1) Local Data Port toward Local Data Port N/A
2) Remote Data Port toward Local Data Port N/A
3) Local Data Port toward Remote Data Port
4) Remote Data Port toward Remote Data Port
5) Terminate Loopbacks
6) Loopback Timeout (min):
None
(20, 60, 120, None)
WARNING: Any loopback will remove data link from service.
(R)eturn (M)ain Menu
ENTER CHOICE>
Initiating a Loopback
To initiate a loopback condition:
1
2
Open the Loopback Settings menu.
Type the number that corresponds to the desired loopback then press
ENTER . The Loopback Settings menu displays the new loopback status.
Clearing a Loopback
To clear a loopback condition:
1
2
Open the Loopback Settings menu.
Type 6 then press ENTER . The system disables the loopback and the
Loopback Settings menu displays.
5-22
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
Setting the Loopback Timeout
The loopback timeout determines the amount of time before a loopback clears
automatically. Choose one of the following:
•
•
•
•
20 minutes
60 minutes
120 minutes
None (disables the loopback timeout)
If you set the loopback timeout to NONE, a loopback runs until
you clear it manually or turn the unit off.
1
2
Open the Loopback Settings menu.
Type 7 then press ENTER . The Loopback Settings menu shows the new
Loopback Timeout setting. Repeat this step until the desired setting
displays.
Campus-REX RS Interface Card User Manual
5-23
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
UPDATING THE CAMPUS-REX FIRMWARE
Before you can upgrade a Campus-RS unit, you must first download the
firmware file(s) to your computer. These files are available on the ADC Web
site, www.adc.com.
1
From the Main Menu, type 4 then press ENTER . The Diagnostics menu
displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:29:35
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DIAGNOSTICS MENU
1) LOOPBACK SETTINGS MENU
2) DOWNLOAD MODE
(R)eturn
ENTER CHOICE>
2
3
Type 2 and press ENTER to select Download Mode.
Type Y and press ENTER to confirm the selection.
The console freezes and the Test LED on the line unit or desktop unit
front panel illuminates, indicating that the Campus-RS unit is in
Download Mode.
4
5
Close the terminal emulation program you are using for the ASCII
terminal.
Start the Download Utility (DNL32.exe).
5-24
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
6
Click Comm, Comm Port, then select the COM port to which the
Campus-RS unit is connected.
7
8
9
Click Comm, Baud Rate, 9600.
Click Protocol, DNL Mode.
In the DNL Mode Options box, set the DNL Rate to Standard.
10 In the DNL Mode Options box, set the Destination to Local.
11 Select the directory and file you want to copy to the Campus-RS unit.
The path and file name display in the Firmware File to Upload box.
12 Click Start Upload.
Within 20 seconds, a status bar displays to indicate upload progress.
When the upload is complete, the unit resets and terminates Download
Mode. If the Test LED remains lit, indicating that the unit is still in
Download Mode, the file was not copied successfully. Repeat the
procedure until the copy is successful.
13 Follow the steps in “Returning Configuration Options to Default Values”
on page 5-5 to restore the Campus-RS unit configuration options to their
default values.
Campus-REX RS Interface Card User Manual
5-25
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring with an ASCII Terminal
5-26
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
MONITORING WITH
AN ASCII TERMINAL
This chapter describes how to use an ASCII terminal to view performance
options, see the previous chapter.
For Information About:
See Page:
Monitoring HDSL Performance
Viewing Local Alarm History
Viewing Product Information
6-2
6-6
6-8
6-10
To view the information described in this chapter, you must first connect an
ASCII terminal to the Campus-RS Desktop Unit or Campus-Star chassis in
which the Campus-REX is installed. See “Set Up an ASCII Terminal” on
page 3-2 for instructions on connecting a terminal. See “ASCII Terminal
Menu Reference” on page A-5 for an illustration of the hierarchical structure
of the ASCII terminal menus.
You may also view this information through the LCD menus. See
“Configuring and Monitoring Through the LCD” on page 4-1 for instructions
on using the LCD panel.
Campus-REX RS Interface Card User Manual
6-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
MONITORING HDSL PERFORMANCE
The Current System Status menu provides a variety of information on the
current performance of the Campus system. To open the Current System
Status menu:
1
From the Main Menu, type 1 then press ENTER . The System Status
Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:14:18
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM STATUS MENU
1) CURRENT SYSTEM STATUS
2) 24 HOUR HDSL PERFORMANCE HISTORY
3) 7 DAY HDSL PERFORMANCE HISTORY
4) LOCAL ALARM HISTORY
5) PRODUCT INFORMATION
(R)eturn
ENTER CHOICE>
6-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
2
Type 1 then press ENTER . The Current System Status menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:14:35
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
CURRENT SYSTEM STATUS
Local Alarms:
Remote Alarms:
Loopback: None
HDSL-A
HDSL-B
LOCAL
REMOTE
--------
mn/cr/mx
na/na/na
00
LOCAL
--------
mn/cr/mx
na/na/na
00
REMOTE
--------
mn/cr/mx
na/na/na
00
--------
mn/cr/mx
na/na/na
00
Margin (dB):
Pulse Attn (dB):
24 Hour ES:
00000
00000
00000
00000
24 Hour UAS:
Last Cleared:
05671
None
00000
05671
00000
(U)pdate (C)lear
(R)eturn (M)ain Menu
ENTER CHOICE>
The Current System Status menu provides the following information:
•
•
•
•
Local Alarms indicates the current local alarm status
Remote Alarms indicates the current remote alarm status
Loopback indicates the current loopback status
Margin indicates the minimum (mn), current (cr), and maximum (mx)
HDSL margin value, measured in dB, relative to the signal-to-noise ratio
required for a Bit Error Rate (BER) of 10-7
•
•
•
•
Pulse Attn indicates the decrease in amplitude of the transmitted signal
as measured at the HDSL receiver
24 Hour ES indicates the number of errored seconds over the last
24 hours
24 Hour UAS indicates the number of unavailable seconds over the last
24 hours
Last Cleared indicates the date and time when the error counter was last
cleared
Campus-REX RS Interface Card User Manual
6-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
The information on the Current System Status menu does not update
automatically. To update this information, type U then press ENTER .
To clear the 24 Hour ES and 24 Hour UAS counters, type C then press
ENTER .
The following sections describe how to monitor HDSL performance history.
24-Hour Performance History
To display HDSL information for the last 24 hours:
1
From the Main Menu, type 1 then press ENTER . The System Status
Menu displays.
2
Type 2 then press ENTER . The 24 Hour HDSL Performance History
screen displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:14:56
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
24 HOUR HDSL PERFORMANCE HISTORY
HDSL-A
HDSL-B
LOCAL
ES/UAS
REMOTE
ES/UAS
LOCAL
ES/UAS
REMOTE
ES/UAS
--------
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
--------
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
--------
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
--------
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
000/000
11:00
11:15
11:30
11:45
12:00
12:15
12:30
12:45
Current
(P)revious (N)ext (U)pdate
(R)eturn (M)ain Menu
ENTER CHOICE>
6-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
To view more history information:
•
•
To view the next page of the report, type N then press ENTER .
To view the previous page, type P then press ENTER .
To update information on this screen, type U then press ENTER .
Performance history information is lost when power is
removed from the Campus unit.
Seven-Day Performance History
To display HDSL information for the last seven days:
1
From the Main Menu, type 1 then press ENTER . The System Status
Menu displays.
2
Type 3 then press ENTER . The 7 Day HDSL Performance History
screen displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:15:13
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
7 DAY HDSL PERFORMANCE HISTORY
HDSL-A
HDSL-B
LOCAL
ES/UAS
REMOTE
ES/UAS
LOCAL
ES/UAS
REMOTE
ES/UAS
--------
--------
--------
--------
Jan 24
Jan 25
Jan 26
Jan 27
Jan 28
Jan 29
Jan 30
Jan 31*
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
00000/00000 00000/00000
*Since Midnight
(U)pdate
(R)eturn (M)ain Menu
ENTER CHOICE>
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
6-5
Monitoring with an ASCII Terminal
To update information on this screen, type U then press ENTER .
Performance history information is lost when power is
removed from the Campus unit.
VIEWING LOCAL ALARM HISTORY
To display alarm history information:
1
From the Main Menu, type 1 then press ENTER . The System Status
Menu displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:14:18
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
SYSTEM STATUS MENU
1) CURRENT SYSTEM STATUS
2) 24 HOUR HDSL PERFORMANCE HISTORY
3) 7 DAY HDSL PERFORMANCE HISTORY
4) LOCAL ALARM HISTORY
5) PRODUCT INFORMATION
(R)eturn
ENTER CHOICE>
6-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
2
Type 4 then press ENTER . The Local Alarm History screen displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:15:34
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
LOCAL ALARM HISTORY
First
Type
HDSL Link,
Current
Last
Nov 31, 1999-12:21:01
Count
ACTIVE Dec 09, 1999-04:30:03
1
0
0
0
0
0
ES,
ES,
HDSL-A
HDSL-B
OFF
OFF
OFF
OFF
OFF
Margin, HDSL-A
Margin, HDSL-B
LOS,
Port
Last Cleared: None
(S)witch to Remote Alarm History
(U)pdate (C)lear
(R)eturn (M)ain Menu
ENTER CHOICE>
This screen shows alarm history of the local unit. If the HDSL line uses two
loops, the screen includes information for both loops. The screen includes
information on the following alarms:
•
•
•
Errored seconds (ES)
Margin
Loss of Signal (LOS)
To view remote alarm history, type S then press ENTER .
To update the information, type U then press ENTER .
To clear the information, type C then press ENTER .
Alarm history information is lost when power is removed from
the Campus unit.
Campus-REX RS Interface Card User Manual
6-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
VIEWING ETHERNET STATISTICS
The REX Statistics screen provides a count of valid Ethernet packets received
and forwarded by the Ethernet and HDSL ports. To open the REX Statistics
screen:
1
From the Main Menu, type 2 then press ENTER . The Data Port Settings
menu displays.
Dec 9, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:16:44
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
DATA PORT SETTINGS
00:20:A7:21:2F:6B
MAC ADDRESS:
10 BASE-T STATUS: Up
1) BRIDGE/ROUTER CONFIGURATION
2) SNMP CONFIGURATION
3) WRITE NVRAM
4) RESET INTERFACE CARD
WARNING: NVRAM must be written and interface card reset for any
configuration changes to take effect.
(R)eturn
ENTER CHOICE>
6-8
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
2
Type 5 then press ENTER . The REX Statistics screen displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version x.xx
13:18:21
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-REX Unit #12
Local I/F: REX
Remote I/F: REX
Circuit ID:
Network Extension Circuit 5001
REX STATISTICS
ETHERNET PORT:
INPUT FRAMES:
0000492348
0000095613
0000000000
0000000000
OUTPUT FRAMES:
DISCARDED FRAMES:
ERRORED FRAMES:
HDSL PORT:
INPUT FRAMES:
0000256138
0000138945
0000000000
0000000000
OUTPUT FRAMES:
DISCARDED FRAMES:
ERRORED FRAMES:
(U)pdate (C)lear
(R)eturn (M)ain Menu
ENTER CHOICE>
The REX Statistics screen monitors the following information for the
Ethernet and HDSL ports:
•
•
Input Frames is the number of frames correctly received by the port
Output Frames is the number of frames correctly transmitted through the
port
•
•
Discarded Frames is the number of frames dropped due to an overflow
of the input or output buffer for the port
Errored Frames is the number of frames received in error from both the
input and output buffers (such as CRC errors, alignment errors, and
dribbling hit errors)
To update the statistics, type U then press ENTER .
To clear the counters, type C then press ENTER .
Campus-REX RS Interface Card User Manual
6-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitoring with an ASCII Terminal
VIEWING PRODUCT INFORMATION
The Product Information screen displays manufacturing information about
the Campus-REX RS Interface Card. This information is important if you
ever need to contact ADC for technical support. To open the Product
Information screen:
1
From the Main Menu, type 1 then press ENTER . The System Status
screen displays.
2
Type 5 then press ENTER . The Product Information screen displays.
May 3, 1999
ADC DSL SYSTEMS INC., CAMPUS RS, Version 4.1e
13:15:50
Local Unit ID: Campus-REX Unit #34
Remote Unit ID: Campus-V.3
Local I/F: REX
Remote I/F: FRAC V.35
Circuit ID:
Network Extension Circuit 5001
PRODUCT INFORMATION
Software Version:
4.1e
B24E
PROM Checksum:
Hardware Version:
FFD0
Desktop
AC
RTC Not Installed
(R)eturn (M)ain Menu
ENTER CHOICE>
The Product Information screen displays the following information:
•
the version number of the Campus-REX software (this also displays in
the heading of all the terminal screens)
•
•
the PROM checksum, a hexidecimal number used to verify unit PROMs
the hardware version of the Campus-REX RS Interface Card
6-10
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
INTERNETWORKING AND
MANAGEMENT OVERVIEW
7
You can configure the Campus-REX as a bridge to forward Ethernet data
based on MAC addresses, or as a router to route Ethernet data based on IP
addresses. You can also configure parameters for management and
encapsulation protocols.
management concepts.
For Information About:
See Page:
MAC-Level Bridging and Spanning Tree Protocol
Static IP Routing
7-2
7-4
Management Protocols
7-11
7-15
Encapsulation Protocols
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
7-1
Internetworking and Management Overview
MAC-LEVEL BRIDGING AND SPANNING TREE
PROTOCOL
The following sections describe the MAC-level bridge and the Spanning Tree
algorithm function.
MAC-Level Bridging
A bridge moves information across an internetwork from a source to a
destination at the link layer (of an OSI reference model). The information is
sent to a physical address known as a Media Access Control (MAC) address.
The Campus-REX provides transparent Ethernet MAC-level bridging. It is a
completely self-contained bridge with a CPU, memory subsystems (RAM,
Flash, etc.), an Ethernet controller and Ethernet drivers, and other glue logic.
It provides complete main bridging tasks of learning, forwarding, filtering,
and hashing/buffer management. Additionally, it offers 802.1d Spanning
Tree protocol, packet encapsulation (through HDLC or PPP framing), and
other local tasks.
Forwarding performance is at a full serial line rate and filtering performance
is at a full Ethernet rate of 14 kpps for 64-byte frames (minimum size).
Spanning Tree
Spanning Tree protocol creates a logical topology to overlay a physical
network. This overlay disables all loops in the data path. Enabling Spanning
Tree ensures a unique, primary path from any node on a network to any other
node. Also, if the primary path is lost, Spanning Tree creates a new primary
path by enabling links in the physical network that were previously disabled
in creating the active topology. The following figure shows an example of
Spanning Tree.
7-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
Example Physical Network*
LAN
Bridge 1
ENET 1
Bridge 2
Bridge 3
LAN
E
N
E
T
Bridge 4
Bridge 5
ENET 3
2
Loop-free Topology
Using Spanning Tree Protocol
LAN
Bridge 1
ENET 1
Bridge 2
Bridge 3
Bridge 4
LAN
E
N
E
T
Bridge 5
ENET 3
2
*This physical configuration is valid only when used
with Spanning Tree to eliminate loops.
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
7-3
Internetworking and Management Overview
To enable or disable Spanning Tree, see “Configure the Campus-REX as a
Bridge or Router” on page 3-19. The Campus-REX uses the Spanning Tree
defaults shown in the table below. These values are user-configurable
through SNMP as part of the Spanning Tree group in RFC 1493.
Spanning Tree Attribute Default Value
ST Bridge Priority
ST Max Age
Hx0000
30 seconds
ST Hello Time
10 seconds
ST Hold Time
10 second
ST Forward Delay
ST Port 1 Priority (LAN)
ST Port 2 Priority (HDSL)
ST Port Path Cost
10 second
0
0
1
STATIC IP ROUTING
Through the static IP routing feature, you can configure the Campus-REX as
an IP router with statically programmed route entries. You can enable this
function as a security feature to prevent eavesdropping and to provide
broadcast filtering, as well as to specify multiple destination gateways. When
static IP routing is enabled, you can access only specific remote IP subnets or
hosts.
Since IP routers make forward or filter decisions based on the network-layer
IP address instead of the MAC hardware address, MAC-level broadcast
frames are prevented from reaching unwanted destinations in the network.
The following example shows a simple Internet Service Provider (ISP) site
that uses the static IP routing feature to filter MAC-level broadcast frames
sourced by ISP Subscriber A from reaching ISP Subscriber B. In this
example, all frames from Subscriber A and Subscriber B are directed to the
router at the Network Access Provider site. From there, frames from both
subscribers are forwarded directly to the Internet.
7-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
The following shows a more complex example of multiple gateways that use
static IP routing to route packets sourced from specific users to different
destination gateways. In this example, packets from each subscriber are
routed through a common hub to a router dedicated to that subscriber.
Campus-REX RS Interface Card User Manual
7-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
When you choose to configure the Campus-REX for static IP routing, set the
configuration options defined in the following table. To set these options, see
“Configuring as a Router” on page 3-23.
7-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
Parameter
Definition
Bridge/Router Mode
Select Bridge or Router. Both Campus-REX units connected
through the HDSL link must be configured as routers for
static routing to work.
Packet Encapsulation
Select either PPP or HDLC. You must set both Campus-REX
units connected through the HDSL link to the same
encapsulation option. For static routing, set this option to
HDLC.
Default Router IP Address Specifies the next hop default router entry. This entry tells the
Campus-REX what to do with a packet that has a destination
address that is not in the Static IP Routing table.
IP Static Routing Table
Specify up to three static route entries, where each entry
includes: destination Subnet or host IP address, destination
Subnet Mask, and the IP address of the next-hop Gateway to
which the packet should be sent. When you configure the
remote end of a point-to-point HDSL connection, you can
leave this table blank and specify a single default router IP
address since all packets will be forwarded to the other end
of the connection. Or for security, you can choose to fill in the
table.
LAN IP Address and
Subnet Mask
Enter the IP address and subnet mask for the LAN Port
(10BASE-T port). These must be configured for static IP
routing to function properly.
Line IP Address and
Subnet Mask
Enter the IP address and subnet mask for the Line Port
(HDSL port). These must be configured for static IP routing
to function properly. When you configure a point-to-point
system, the Line IP address of both units must belong to the
same IP subnet and the Line Subnet Mask parameters for
both units must be the same. The Line IP Address and
Subnet Mask for a point-to-point system are isolated and
hidden from the rest of the network—you may use any
subnet.
Configure a Static Route entry in any of the external routers that may have
been specified as a Default Router IP address or as a Gateway address in the
Campus-REX. This is required because the Campus-REX does not send
periodic route updates using protocols like Routing Information Protocol
(RIP) or Open Shortest Path First (OSPF) so that other external routers can
automatically update their routing tables. This implementation prevents other
Campus-REX RS Interface Card User Manual
7-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
parties from eavesdropping to discover routes to remote sites connected
through the HDSL line. The format of this entry varies among different router
vendors, but it will typically be in the form of Destination, Mask, and Next
Hop Gateway, where:
•
•
destination is the remote IP subnet or host address
gateway is the LAN IP address of the Campus-REX on the same subnet
as the external router
The following figure shows an example of a point-to-point HDSL system
with hypothetical parameter values.
7-8
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
Campus-REX IP Addresses
Each Campus-REX unit has two IP addresses, the LAN address and the Line
address. In the following figure, the non-shaded side of the Campus-REX
indicates the LAN address, which is for the Ethernet (10BASE-T)
connection. The shaded side of the Campus-REX is the IP Line address,
which is for the HDSL connection. Note that the IP Line address is different
from the LAN addresses. When connecting two Campus-REX units
point-to-point through HDSL, the IP Line addresses are completely isolated
and hidden from the rest of the network. You can assign any subnet to the
Line IP addresses.
When routing, data travels one hop at a time. The figure below shows
destination and next hop IP addresses. The destination address indicates the
network and subnetwork of the next hop. The next hop is the next-stop IP
address node. The default gateway is the upstream routing device. Use this
example to help you determine/record static IP routing addresses.
Campus-REX RS Interface Card User Manual
7-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
Default Gateway: upstream router address: 192.168.13.209
Destination: 192.168.242.0 Next Hop 192.168.240.10
Mask: 255.255.255.0
IP: 192.168.13.210
Mask: 255.255.255.0
IP: 192.168.240.1
Mask: 255.255.255.0
The
Internet
Provider Router
DNS Server IP: 192.168.240.20
Mask: 255.255.255.0
Provider Server
Default Gateway: 192.168.240.1 Destination: 192.168.242.0
Mask: 255.255.255.0 Next Hop 172.16.100.2
Provider Modem
IP: 192.168.240.10
Mask: 255.255.255.0
IP: 172.16.100.1
Mask: 255.255.255.0
Default Gateway: 172.16.100.1
IP: 172.16.100.2
IP: 192.168.242.1
Mask: 255.255.255.0
Mask: 255.255.255.0
IP: 192.168.242.5
Mask: 255.255.255.0
Default Gateway: 192.168.242.1
DNS: 192.168.240.20
Subscriber Modem
Subscriber PC
7-10
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
MANAGEMENT PROTOCOLS
SNMP is used for remote configuring of system and bridge parameters,
monitoring statistics, and performing advanced management. BOOTP is
available for the Campus-REX to download system software code.
SNMP
This messaging protocol specifies how to send information between a
Network Management Station (NMS) and managed devices on a network.
Managed devices (such as the Campus-REX) have agent software or
firmware that interprets SNMP requests and responds to them. The NMS
communicates with the agents in the managed devices to:
•
•
•
set configuration options
read configuration information
read status parameters
A Management Information Base (MIB) defines these configuration and
status parameters. The Internet Engineering Task Force (IETF) specifies
standard MIBs for certain types of devices, ensuring that any NMS can
manage them. Additionally, vendors can issue proprietary MIBs for their
devices that provide higher management functionality.
The following table shows the configuration parameters that must be
maintained and restored to the Campus-REX through the system’s local
console port. These parameters are stored in the Campus-REX NVRAM
(non-volatile memory) and are used in subsequent initializations.
Campus-REX RS Interface Card User Manual
7-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
Attribute
Factory Default
Local IP Address
0.0.0.0
Local Subnet Mask
255.255.255.0
0.0.0.0
Boot Router IP Address
Default Router IP Address
Boot Server IP Address
Boot Mode (local, network)
0.0.0.0
0.0.0.0
Local
Image Load Mode (local, network) Local
SNMP RO Community String
SNMP RW Community String
Trap Receiver 1 IP Address
Public
Private
0.0.0.0
Trap Receiver 1 Community String Null string
Trap Receiver 2 IP Address 0.0.0.0
Trap Receiver 2 Community String Null string
Authentication Trap enable/disable Disable
ST Enable/disable
Disable
Campus-REX SNMP Agent
An agent is software or firmware code resident in managed devices (such as
the Campus-REX, modems, nodes, routers and hubs). Agents translate data
on remote networks into code the NMS can read. The NMS uses SNMP as
the transport mechanism to communicate with an agent. SNMP uses the
standard Internet Protocol (IP) to transport incoming and outgoing messages
to the appropriate agent or NMS address. Each SNMP command requires an
IP address or NMS from the agent to transport these messages.
7-12
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
The Campus-REX provides an SNMP agent that supports several MIBs for
the management of the system. The SNMP agent can process datagrams
received from both the Ethernet interface (LAN) and the HDSL interface
(Line). The agent and the protocol stack complies with the following RFCs:
•
•
•
•
•
•
RFC 1155, Structure of Management Information (SMI)
RFC 1157, Simple Network Management Protocol (SNMP)
RFC 826, Address Resolution Protocol (ARP)
RFC 792, Internet Control Message Protocol (ICMP)
RFC 791, Internet Protocol (IP)
RFC 768, User Datagram Protocol (UDP)
MIB and Trap Support
Each managed device has configuration, status, and statistical information
that defines its functionality and operational capabilities. All of these
elements make up the MIB for the device being managed. The MIB defines
the kind of information an NMS can retrieve from a managed device and the
settings an NMS can control in a managed device.
The Campus-REX supports the following MIBs:
•
RFC 1213, Management Information Base for Network Management of
TCP/IP-Based Internets: MIB-II. Covers: system, interfaces, IP, ICMP,
UDP, and SNMP groups. The Ethernet interface has the ifIndex value
of 1.
•
•
•
RFC 1215, A Convention for Defining Traps for Use with the SNMP.
Covers: ColdStart, linkUp, linkDown, and authenticationFailure traps.
Link status traps are sent for events related to Ethernet.
RFC 1493, Definition of Managed Objects for Bridges. Covers: Base,
Spanning Tree, and transparent bridging groups. The Spanning Tree
MIB can only be accessed if the Spanning Tree protocol is enabled.
Proprietary REX MIB, an enterprise specific MIB designed for the agent
in the Campus-REX for managing the HDSL portion of the unit.
Campus-REX RS Interface Card User Manual
7-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
You can download product-specific MIBs through the Internet at
ftp.adc.com. Use the following:
•
•
•
•
•
FTP ftp.adc.com
log in using anonymous as your login name
use guest or your e-mail address as your user password
enter cd /snmp/rex/mib
get pgrexmib.txt
BOOTP
BOOTP is used to download configuration information to the Campus-REX
from a BOOTP server. You can also configure these parameters and save
them in NVRAM so that BOOTP can be bypassed. It is recommended that the
BOOTP server be connected to the same segment as the Campus-REX
10BASE-T port.
The Campus-REX supports both local and remote loading of bootstrap
information (IP configuration only) and operational image code. Local
bootstrap configuration information is contained in NVRAM. Local image
code is contained in Flash devices for local loading of operational code.
When loading over the network is preferred, you can use BOOTP (RFC 951)
to obtain bootstrap information and image files. Booting and image download
are controlled by the use of two attributes which are Boot Mode and Image
Load Mode. Other applicable RFCs are:
•
•
RFC 1533, DHCP Options and BOOTP Vendor Extensions
RFC 1542, Clarification and Extensions for the Bootstrap Protocol
(Updates 951)
7-14
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
ENCAPSULATION PROTOCOLS
You can select from two packet encapsulation formats for Ethernet data for
the Campus-REX:
•
•
High-level Data Link Control (HDLC)
Point-to-Point Protocol (PPP)
HDLC is the default setting, and should be used in most applications. Use
PPP only if the remote unit is a synchronous interface card, such as V.35.
When PPP is selected from bridging mode, the Campus-REX runs the
Bridging Control Protocol (BCP) RFC 1638. PPP provides interoperability
with other product types. HDLC is a compressed version of the encapsulation
protocol and is preferable when there is like equipment.
Campus-REX RS Interface Card User Manual
7-15
Download from Www.Somanuals.com. All Manuals Search And Download.
Internetworking and Management Overview
7-16
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL REFERENCE
A
SPECIFICATIONS
Physical
Height
0.7 inches (1.8 cm)
2.8 inches (7.0 cm)
5.6 inches (14.1 cm)
4.0 ounces (113.4 gm)
Width
Depth
Weight
Equipment Interface
Ethernet Port
Connector
RJ-45C, 10BASE-T
14 kpps (64-byte frames) max
2.7 kpps Full-duplex
HDLC or PPP
Bandwidth Filtering
Forwarding
Encapsulation Format
Bridging
IEEE 802.1d Transparent Bridging with
Spanning Tree Protocol
Clock Options
Internal ( 50 ppm), HDSL
Electrical
Power Consumption
3.5W max
Campus-REX RS Interface Card User Manual
A-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Reference
Environmental
Operating Temperature
0° to 50° C
Relative Humidity
0 to 85%
Electromagnetic Emissions
Safety Compliance
Per FCC Part 15 Class A, CE
UL, CSA, CE
ADC reserves the right to change features and specifications without notice.
DEFAULT SETTINGS
The following table lists default settings for Campus-REX RS Interface Card
configuration options:
Parameter
Default
Bridge/Router Settings
Bridge/Router Mode
Encapsulation
Timing Source
Spanning Tree
Boot Mode
Bridge
HDLC
Internal
Disable
Local
HDSL Settings
HDSL Mode
Standard
T1
HDSL Rate
XCVR Mode
Auto
Loopback Timeout
20 Minutes
A-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Reference
LCD MENU REFERENCE
The illustration on the following pages diagrams the LCD menu structure.
ENTER
S/W REV
S/W CKSUM
CAMPUS RS
I/F: REX
NEXT
NEXT
H/W CONFIG
NEXT
LOCAL UNIT ID
Press ENTER
NEXT
REMOTE UNIT ID
Press ENTER
NEXT
REMOTE I/F
NEXT
CIRCUIT ID
Press ENTER
NEXT
Press ENTER to
factory reset
NEXT
ENTER
HDSL LINK
CONFIG & STATUS
OPERATING MODE
NEXT
NEXT
XCVR MODE
NEXT
LOOP MODE*
NEXT
HDSL RATE
NEXT
MARGIN (LOC/RMT)
NEXT
Continued next page
* Option displays only in extended mode.
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
A-3
Technical Reference
Continued from previous page
PERFORMANCE
STATUS
LOC ES (24HR)
RMT ES (24HR)
LOC UAS (24HR)
RMT UAS (24HR)
LAST CLEARED
Press ENTER to
clear error cnts
ENTER
REX MODE
DATA PORT
CONFIG & STATUS
CONFIGURE REX
SETTINGS
TIMING SOURCE
ENCAPSULATION
SPANNING TREE
NEXT
NEXT
MAC ADDRESS
NEXT
10BaseT STATUS
Press ENTER to
reset interface
NEXT
ENTER
ALARM
CONFIG & STATUS
CURRENT ALARMS
LOC RMT
NEXT
NEXT
LINK ES MARGIN
AUTOSYNC
HDSL LINK ALARMS
CONFIG & STATUS
NEXT
HDSL ES
THRESHLD
MARGIN THRESHLD
AUTOSYNC CFG ALM
CURRENT
LOC ALM
LOCAL I/F ALARMS
CONFIG & STATUS
NEXT
LOC LOSS
OF SIG
RMT I/F ALARMS
CURRENT
RMT ALM
CONFIG & STATUS
NEXT
RMT LOSS
OF SIG
ENTER
None
Local to
Remote
DIAGNOSTICS
LOOPBACK MODE
NEXT
NEXT
Remote to
Remote
LPBK TIMEOUT
NEXT
REX STATISTICS
ETHERNET PORT
FRAMES
NEXT
HDSL PORT FRAMES
A-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Reference
ASCII TERMINAL MENU REFERENCE
The illustration on the following pages shows the ASCII terminal menu
structure for the Campus-REX unit.
Main Menu
System Status Menu
Current System Status Menu
24 Hour HDSL Performance History
7 Day HDSL Performance History
Local Alarm History Menu
Data Port Settings
Bridge/Router Configuration
SNMP Configuration
Write NVRAM
Reset Interface Card*
System Settings
Menu
System Parameters
HDSL Parameters
Diagnostics Menu
Loopback Settings Menu
REX Statistics
Download Mode
Remote Logon
* Option displays only when configuration is changed that requires you to save to
NVRAM and then RESET the modem.
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
A-5
Technical Reference
A-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
ABBREVIATIONS
B
2 Binary,1 Quaternary
2B1Q
BER
Bit Error Rate
Campus Management Unit
Clear to Send
CMU
CTS
Data Circuit-Terminating Equipment
Data Set Ready
DCE
DSR
DSX-1
DTE
DS1 Cross-connect Frame
Data Terminal Equipment
Data Terminal Ready
DTR
Errored Seconds
ES
High-level Data Link Control
High-bit-rate Digital Subscriber Lines
Loss of Signal
HDLC
HDSL
LOS
Non-volatile Random Access Memory
Plain Old Telephone Service
Point-to-Point Protocol
Receive Data
NVRAM
POTS
PPP
RD
Receive Line Signal Detect
RLSD
Campus-REX RS Interface Card User Manual
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Abbreviations
Rate Selectable
RS
Request to Send
RTS
SCR
SCT
SD
Serial Clock Receive
Serial Clock Transmit
Send Data
Signal-to-Noise Ratio
Terminal Timing
SNR
TT
Unavailable Seconds
Underwriters Laboratory
UAS
UL
B-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
THE DOCUMENTATION SET
C
This table describes the manuals and guides in the Campus-RS
documentation set.
Document
Description
Campus-Star User
Manual
Contains instructions for setting up and using a
Campus-Star. The manual includes instructions for
installing Line Units and interface cards into the
Campus-Star chassis.
Campus-RS Line Unit
User Manual
Describes the features of the Campus-RS Line Unit
and provides installation instructions.
Campus-RS Desktop
Unit User Manual
Describes the features of the Campus-RS Desktop
Unit and provides instructions for installing interface
cards, and connecting the unit to an HDSL line.
Campus Interface Card
User Manuals
Describes the features of the individual Campus
interface cards, one card per manual, and contains
instructions for configuring and monitoring the
system through the cards.
Campus-REX RS Interface Card User Manual
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
The Documentation Set
C-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTACTING ADC
D
PRODUCT SUPPORT
ADC Customer Service Group provides expert pre-sales and post-sales
support and training for all its products.
Technical support is available 24 hours a day, 7 days a week by contacting
the ADC Technical Assistance Center.
•
•
•
Quotation Proposals
Sales Assistance
Ordering and Delivery
General Product Information
800.366.3891 extension 73000
(USA and Canada)
952.917.3000
Fax: 952.917.3237
•
Complete Solutions (from concept to
installation)
Systems Integration
800.366.3891, extension 73000
(USA and Canada)
•
•
•
•
•
•
•
•
•
•
•
•
Network Design and Integration Testing
System Turn-Up and Testing
952.917.3000
Network Monitoring (upstream or downstream)
Power Monitoring and Remote Surveillance
Service/Maintenance Agreements
Systems Operation
Technical Information
ADC Technical Assistance Center
800.638.0031
714.730.3222
Fax: 714.730.2400
Email: [email protected]
System/Network Configuration
Product Specification and Application
Training (product-specific)
Installation and Operation Assistance
Troubleshooting and Repair/Field Assistance
Continued
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
D-1
Contacting ADC
•
•
•
www.adc.com/Knowledge_Base/index.jsp
www.adc.com/library1/
Online Technical Support
Online Technical Publications
ADC Return Material Authorization (RMA)
number and instructions must be obtained
before returning products.
Product Return Department
800.366.3891 ext. 73748 or
952.917.3748
Fax: 952.917.3237
Email: repair&[email protected]
All 800 lines are toll-free in the USA and Canada.
ADVANCE REPLACEMENT
Any product determined by ADC not to comply with the applicable warranty
within 30 calendar days from the date of shipment to the Buyer, or as
otherwise authorized, are eligible for advance replacement free of charge. A
replacement product will be shipped to the Buyer within 24 hours of ADC's
receipt of notification from the Buyer.
If products returned to ADC for advance replacement are not received by
ADC within 30 calendar days of shipment of the replacement product or if no
trouble is found (NTF) as determined by ADC, the Buyer will be responsible
for payment of the cost of the replacement product.
BILLING
Equipment returned for repair, replacement, or credit, whether in warranty or
out of warranty, which is found to be damaged due to customer negligence or
which has had parts removed will be repaired on a time and material basis.
ADC will contact the customer for disposition on any equipment that is in this
condition or found to be unrepairable.
In the event that the returned equipment is not covered by warranty, ADC will
contact the customer with estimated repair or replacement charges and obtain
customer disposition of the product if a purchase order has not been provided.
Equipment returned for repair or replacement is subject to a $70 per unit NTF
(no trouble found) charge in the event that diagnostic evaluation reveals no
evidence of functional failure or physical defects.
D-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
timing source ............................ 3-30
assistance ............................................ D-1
authentication error trap generation ..... 5-9
Auto Master/Slave mode
Numerics
10BASE-T
checking line status .....................2-7
connecting the Ethernet cable
.......................................2-4 to 2-6
port configurations ......................2-4
status .........................................4-13
24-hour HDSL alarm history
ASCII terminal ............................6-4
LCD .............................................4-7
7-day HDSL alarm history ...................6-5
ASCII terminal ..............5-12 to 5-14
LCD ............................................ 4-4
AutoSync Mode
A
ASCII terminal ............................6-4
alarm status
setting on ASCII terminal
...................................3-11 to 3-18
setting on LCD ................3-8 to 3-11
ASCII terminal ..................6-2 to 6-6
LCD .................................4-5 to 4-10
alarm thresholds
billing information .............................. D-2
configuring ....................3-19 to 3-23
Bridge/Router Mode .......................... 3-19
ASCII terminal
bridge configuration ......3-21 to 3-23
communications settings .............3-5
configuring alarms ........5-15 to 5-16
connecting .........................3-2 to 3-5
logging on ...................................3-5
C
cable for Ethernet port ......................... 2-4
Campus Management Unit
See LCD
Campus-REX RS Interface Card User Manual
Index-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Campus-768 ......................................... 1-2
Campus-E1 ........................................... 1-2
Campus-Star
router .............................3-23 to 3-28
installing the card ........................ 2-3
Campus-T1 ........................................... 1-2
LCD .......................................... 4-12
clearing loopbacks
connecting an ASCII terminal .... 3-3
installing the card ....................... 2-2
downloading new firmware ............... 5-24
dropped frames
ASCII terminal .......................... 5-22
LCD .......................................... 4-11
CMU
LCD .......................................... 4-14
E
See LCD
Encapsulation
communications settings for ASCII
ASCII terminal .............3-21 to 3-23
errored second
terminal ............................................ 3-5
configuring
See also ASCII terminal
See also LCD
connecting
ASCII terminal ..................3-2 to 3-5
Ethernet cable ...................2-4 to 2-6
current HDSL status ...................6-2 to 6-6
Ethernet
D
date ..................................................... 5-18
address ........................................ 7-9
checking line status ..................... 2-7
connecting the cable .........2-4 to 2-6
port address ............................... 3-26
status ......................................... 4-13
default configuration settings
restoring on ASCII terminal
.......................................5-5 to 5-6
restoring on LCD ........................ 4-3
E-2
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Extended Mode
installing in
Campus-Star ............................... 2-3
desktop unit ................................. 2-2
IP router ............................................... 7-4
table ........................................... 3-27
setting on ASCII terminal
...................................3-11 to 3-15
setting on LCD ................3-8 to 3-10
F
features .................................................1-2
firmware version ................................4-12
firmware version, updating ................5-24
frame statistics
L
LAN address ........................................ 7-9
ASCII terminal ..................6-8 to 6-9
LCD ...........................................4-14
navigating menus ..............4-2 to 4-3
H
HDSL
setting .....................3-7 to 3-18
status
legacy Campus products ...................... 1-2
Line address ......................................... 7-9
Link alarm ............................................ 4-5
ASCII terminal .........6-2 to 6-6
LCD ...........................4-5, 4-14
timing ............................3-29 to 3-31
history of alarm conditions
ASCII terminal .......... 6-4, 6-6 to 6-7
LCD .............................................4-7
history ...............................6-6 to 6-7
LCD ............................................ 4-8
local HDSL loopback ........................ 5-20
local IP address
I
Image Load Mode ..................5-10 to 5-11
initiating loopbacks
bridge ............................3-21 to 3-23
router ......................................... 3-26
ASCII terminal ..........................5-22
LCD ...........................................4-11
Campus-REX RS Interface Card User Manual
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
local subnet mask
bridge ............................3-21 to 3-23
Master mode
router ......................................... 3-26
local to local loopback ....................... 5-20
local to remote loopback ...........4-10, 5-21
logging off of ASCII terminal ............. 5-3
Loop Configuration
LCD ............................................ 4-4
MDI and MDI-X port configuration .... 2-4
N
setting on ASCII terminal ......... 3-13
setting on LCD ............................ 3-9
loopback timeout
navigating menus
ASCII terminal ........................... 5-4
LCD ..................................4-2 to 4-3
network SNMP management .....5-6 to 5-9
Next button .......................................... 4-2
ASCII terminal .......................... 5-23
LCD .......................................... 4-12
loopbacks
LCD ..............................4-10 to 4-13
LOS alarm
P
password ............................................ 5-19
port statistics
ASCII terminal ..................6-6 to 6-7
LCD ............................................ 4-8
loss of signal alarm
LCD .......................................... 4-14
product release dates .......................... 4-12
PROM checksum ............................... 4-12
protocols ................................7-11 to 7-15
provisioning
See LOS alarm
M
MAC-level bridging ............................. 7-2
main chassis information ................... 4-12
management protocols ...........7-11 to 7-14
margin
See ASCII terminal
See LCD
alarm ........................................... 4-5
ASCII terminal ..................6-2 to 6-6
LCD .......................................... 4-14
E-4
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
R
received frames
3-13
ASCII terminal ..................6-8 to 6-9
remote alarms
setting on LCD ..................3-8 to 3-9
starting loopbacks
ASCII terminal ..................6-6 to 6-7
LCD .............................................4-9
remote to remote loopback ........4-10, 5-21
restoring default settings
ASCII terminal .......................... 5-22
LCD .......................................... 4-11
startup parameters .............................. 7-14
configuring ....................5-10 to 5-11
static IP routing .................................... 7-4
statistics
ASCII terminal ..................6-8 to 6-9
LCD .......................................... 4-14
ASCII terminal ..................5-5 to 5-6
LCD .............................................4-3
Returns ................................................ D-3
router ....................................................7-4
configuration .................3-23 to 3-28
IP static router table ..................3-27
HDSL ................................6-2 to 6-6
straight-through cable .......................... 2-4
S
ASCII terminal ..............5-17 to 5-20
Slave mode
technical assistance ............................. D-1
technical specifications ....................... A-1
terminal
ASCII terminal ..............5-12 to 5-14
SNMP .....................................7-11 to 7-14
configuring ........................5-6 to 5-9
Spanning Tree ......................................7-2
ASCII terminal ..............3-21 to 3-23
LCD ...........................................3-20
specifications ....................................... A-1
See ASCII terminal
testing
Ethernet line ................................ 2-7
loopbacks
ASCII terminal .....5-20 to 5-23
LCD .....................4-10 to 4-13
time .................................................... 5-18
Campus-REX RS Interface Card User Manual
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
timeout
ASCII terminal .......................... 5-23
LCD .......................................... 4-12
timing source ....3-21 to 3-23, 3-29 to 3-31
Transceiver Mode
World Wide Web .................................D-1
ASCII terminal ..............5-12 to 5-14
LCD ............................................ 4-4
transmission rate ........................1-2 to 1-5
setting ..............................3-7 to 3-18
transmitted frames
XCVR Mode
See Transceiver Mode
ASCII terminal ..................6-8 to 6-9
LCD .......................................... 4-14
trap generation ..................................... 5-9
E-6
Campus-REX RS Interface Card User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
ADC DSL Systems, Inc.
14402 Franklin Avenue
Tustin, CA 92780-7013
Tel: 714.832.9922
Fax: 714.832.9924
Technical Assistance
Tel: 800.638.0031
Tel: 714.730.3222
Fax: 714.730.2400
ISO 9001/TL 9000
DNV Certification, Inc.
REGISTERED FIRM
´+cH¶5S¨