3M Door II 2529 User Manual

Fibrlok II 2529  
Universal Optical Fiber Splice  
Instructions  
January 1994  
Issue 1, 34-7035-4458-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.0 General  
1.01  
The 3M brand Fibrlok II 2529 Universal Optical Fiber Splice provides permanent mechanical splices for  
single- or multimode fiber having 125 m diameter cladding. The Fibrlok II 2529 Universal Splice is  
designed to accommodate any combination of fibers with coating diameters from 250 m to 900 m.  
1.02  
All Fibrlok II 2529 Universal Optical Fiber Splices are gray in  
Cap  
color and are marked with the 3M Fibrlok II logo on the splice  
cap.  
End Plug  
(each end)  
1.50" (38.1 mm)  
0.250"  
(6.4 mm)  
.150"  
(3.8 mm)  
Jacket  
Fiber Entry Port  
(each end)  
1.03  
Fibrlok 2501 Assembly Tool  
Pivoted Handle  
(shown open)  
Splice Holding  
Cradle  
Fiber Alignment  
Guides (2)  
Fiber Retention  
Pad  
Toggle Arm  
Toggle Arm  
Fiber Retention  
Pad  
Finger Cutout  
Instruction Label  
(2)  
Base  
Fiber Cleave  
Length Gauge (both  
ends of tool)  
Mounting Holes  
(4)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.04  
Tools and Materials Required are as follows:  
1.05  
Some Compatible Organizers are:  
• 3M 2118, 3M 2524, 3M 2672  
• AT&T UC-SS/M1  
• GTE Part 910470 0000, 910470 1000  
• Siecor M67-070  
• Keptel LightLink  
• Fibrlok2500 or 2501 Assembly Tool  
• Plastic Coating (Buffer) Stripper  
• Reagent Grade Isopropyl Alcohol  
• Lint-free Wipes  
• Cleaver  
• Fibrlok 2505 Assembly Tool  
Mounting Adaptor (optional)  
Others compatible with minor modifications:  
• DiTel UST 3000, UST 3010, UST 3500  
• AT&T 846 280 626, 846 280 634,  
846 280 642, 846 280 659  
• Fibrlok II Video Instruction Tape (optional)  
Tool Kit (optional)  
• Raychem FOSC 100/TK  
2.0 Splicing Set-Up  
2.01  
The splicing area should be clean, dry and well-lighted.  
A clean, well-organized splicing area will improve splice  
efficiency and minimize the risk of contamination of fibers or  
splices.  
2.02  
Open the buffer tubes, expose and clean the fibers per your  
company practice.  
Note:  
Storage, use and disposal of isopropyl alcohol should be  
per your company health, safety and environmental  
instructions. Refer to solvent label or Material Safety  
Data Sheet.  
2.03  
See Section 6.0 for recommended procedures for fiber  
organization and splice storage.  
2.04  
Remove Fibrlok splice from protective package. Load the  
splice into the assembly tool by pressing firmly at the ends of  
the splice.  
Note:  
Carefully follow health, safety and environmental  
information on Fibrlok II Splice label or Material Safety  
Data Sheet.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.05  
If using the Fibrlok 2501 Assembly Tool, rotate the toggle  
arms for the appropriate fiber size.  
Inward – 250  
m
Outward – 900  
m
3.0 Fiber Preparation  
3.01  
Remove the minimum length of fiber required to prepare and  
splice the fibers.  
1" to 2" (25 mm - 51 mm)  
(depending on cleaver)  
3.02  
Strip approximately 1 to 2 inches (25 mm to 51 mm) of  
plastic coating from the fiber using a mechanical stripper.  
Note:  
The stripper should be in good operating condition to  
prevent scratches or other damage to the glass cladding.  
3.03  
Clean the bare glass by pulling the fiber through an alcohol  
soaked lint-free wipe. This will remove any fragments or dirt  
remaining on the fiber.  
Note:  
Note:  
Do not wipe the fibers more than two times, and limit the  
time that the bare fiber is exposed to the atmosphere.  
Carefully follow health, safety and environmental  
information on container label or Material Data Sheet for  
isopropyl alcohol being used.  
3.04  
Cleave fiber to 12.5 mm 0.5 mm (0.492 0.020 inches).  
Important: The Fibrlok II 2529 Universal Splice uses a cleave length of  
12.5 mm 0.5 mm (0.492 0.020 inches) for both 250 m and  
900 m coated fibers.  
Note:  
The cleaver should be in good operating condition and used  
in accordance with the manufacturer's instructions. It is  
recommended that the cleaver provide a consistent cleave-  
to-coating length within 0.5 mm. In addition, standard  
cleavers should produce cleaved ends within 2of  
perpendicular and free of major defects. Cleavers  
specifically designed to produce controlled, angled cleaves  
of greater than 2may also be used with the FibrlokII  
Optical Splice.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.05  
Check the cleave length using the 12.5 mm cleave length  
gauges on the Fibrlok Assembly Tool. Adjust the cleaver to  
provide the prescribed cleave lengths. Check cleave lengths  
periodically during subsequent splicing operations.  
Note:  
Do not allow cleaved end to contact tool. Do not clean  
the fibers again after they have been cleaved.  
250 µm 900 µm  
250 µm : 12.5 mm  
900 µm : 14.0 mm  
900 µm : 12.5 mm  
4.0 Splice Assembly  
4.01  
Push the fiber down into the fiber retention pad on the proper  
side of the splice.  
Note:  
Hold the coated portion of the fiber ONLY. Do not allow  
the cleaved end to contact any surface before insertion  
into the splice.  
4.02  
Grasp the coated fiber about .25 inches (6 mm) from the bare  
glass and move the fiber end onto the fiber alignment guide  
on the assembly tool such that the end is resting on the  
alignment guide outside of the splice.  
Note:  
Note:  
When splicing 250 m to 900 m coated fiber, always  
insert the 250 m coated fiber first.  
Fiber should be placed in the retention pad and inserted  
into the splice immediately following cleaning to  
minimize exposure to the atmosphere and reduce the risk  
of contamination.  
Note:  
Push fiber straight into fiber alignment guide,  
NOT AT AN ANGLE.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.03  
Gently continue pushing the fiber into the splice until  
resistance is felt. When fully inserted, the first fiber should be  
straight or have a slight bow – up to .1 inch (3 mm).  
Note:  
If properly inserted, bare glass should not be visible  
outside of splice. If bare glass is visible, pull back slightly  
on fiber and continue insertion until resistance is met.  
Never fully remove fibers from splice after initial  
insertion. Do not pull on fiber after it has been properly  
inserted.  
4.04  
4.05  
Prepare second fiber (strip, clean and cleave) as described in  
Section 3.  
Lay fiber into foam retention pad and begin to insert the fiber  
end into the splice, as in 4.01 and 4.02.  
4.06  
4.07  
Gently push the second fiber in small increments straight  
through the alignment guide into the fiber entry port. As the  
coating of the second fiber enters the fiber entry port, watch  
for the bow in the first fiber to increase. This occurs when the  
end face of the second fiber contacts the first fiber and pushes  
the first fiber slightly back out of the splice. Continue gently  
pushing the second fiber until it meets resistance.  
Following proper insertion, the second fiber will be  
approximately straight, but may have up to a .1 inch (3 mm)  
maximum bow. At this point, the first fiber will have a larger  
bow than the second fiber and larger than it had initially.  
4.08  
Push the first fiber back against the second fiber until there  
are equal bows in both fibers.  
Note:  
Do not pull on either of the fibers following  
establishment of the bows in the first and second fibers.  
The fiber ends must be held together by the compressive  
forces induced by the bows to produce a low loss splice.  
If fiber bows are NOT observed to move as described,  
repeat steps 4.02 – 4.07 of Splice Assembly but DO NOT  
fully remove fibers from the splice. If bow movement is  
still not observed, remove fibers, strip, clean and re-  
cleave, checking for proper cleave length. Re-splice per  
splicing procedure using a new splice.  
Do not attempt to "tune" or optimize the splice as this  
may result in higher splice loss. The FibrlokII Splice is  
not designed to be "tuned." Fiber alignment does not  
occur until the splice is activated.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.09  
Pivot the handle of the Fibrlok Assembly Tool down until it  
contacts the cap of the Fibrlok Splice. Squeeze the handle of  
the assembly tool as shown in order to close cap and  
actuate the splice. When possible, secure the tool to a  
work surface for added support. A snap sound will be  
heard when the splice is actuated.  
4.10  
Remove the Fibrlok Splice from the assembly tool by first  
removing the fibers from the foam retention pads and then  
lifting the splice from the splice holding cradle.  
Note:  
In the event a splice must be refabricated, simply cut the  
fibers at each end of the splice (this will remove 1-1/2" of  
fiber from the loop) and re-splice per instructions. Splice  
fabrication will require a new splice and a length of 2  
inches on each fiber.  
DO NOT REMOVE FIBERS AND RE-USE FIBRLOK SPLICES.  
5.0 Fiber Repositioning  
5.01  
If high loss is observed after splice has been actuated, it is  
possible that the fiber ends are separated. In this case, lift the  
splice cap and reposition fiber ends, as instructed below.  
NOTE: DO NOT COMPLETELY REMOVE FIBERS FROM  
FIBRLOK SPLICES.  
5.02  
While the splice is in the splice holding cradle, insert the short  
prongs of the Fibrlok II Splice Cap Lifter into the two holes  
on the side of the splice. The cap lifter will be at an angle to  
the splice. The long prongs will be resting against the top of  
the splice cap.  
5.03  
Slide the bottom of the cap lifter inward until it is in a vertical  
position, lifting the splice slightly out of the cradle.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.04  
5.05  
Hold the cap lifter in place with one hand and push down on  
the ends of the splice with the other hand. This action should  
reseat the splice into the holding cradle and lift the cap at the  
same time.  
Repeat fiber centering and splice actuation (See step 4.06 –  
4.09.) If after two attempts an acceptable splice loss is not  
obtained, remove fiber, strip, clean and re-cleave. Re-splice  
using a new splice.  
6.0 Fiber Organization and Splice Storage  
6.01  
When storing fiber slack in a splice tray, the spliced fiber ends  
will twist one full turn for each full loop of fiber being stored.  
This rotation places stress on the fibers. This rotational stress  
makes fiber organization more difficult and may affect fiber/  
splice performance, particularly in 900 m coated fibers. The  
stiffness of the 900 m fiber does not distribute this stress in  
the same manner as 250 m coated fiber. The following  
procedure is strongly recommended when splicing 900 m  
coated fibers and will improve fiber organization when  
splicing all fiber types.  
6.02  
6.03  
Secure the buffer tubes of the fibers to be spliced to the tray  
so that the fibers are free to rotate through the point of  
attachment.  
Select the first two fibers to be spliced and lay them into the  
tray. Trim the fibers so they are the right length for splicing  
plus approximately 1 to 2 inches (2.5 to 5 cm) for fiber end  
preparation.  
6.04  
Place the splice assembly tool close to or on top of the splice  
tray. Match the orientation of the tool to that of the splice  
holder or tray whenever possible.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.05  
6.06  
6.07  
Remove the minimum amount of fiber required for fiber  
preparation and splicing. Remove less than one loop if  
possible.  
Prepare fibers and complete splice as described in Section 3  
and 4.  
Carefully lay the splice on top of the holder without securing  
the splice into the holder.  
6.08  
For 250 to 250 m and 900 to 900 m splices:  
a. Store the shorter of the two fibers in the tray.  
b. Observe how the splice lays in its relaxed state. Rotate the  
splice through the smallest possible angle to install it in the  
tray.  
c. Store the second fiber.  
6.09  
For 250 to 900 m splices:  
a. Store the 900 m fiber first.  
b. Grasping the splice by the 900 m fiber, observe how the  
splice lays in its relaxed state. Rotate the splice through  
the smallest possible angle to install it in the tray.  
c. Store the 250 m fiber.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7.0 Splicing Accessories  
7.01  
The 3M Fibrlok2524 Splice Organizer Tray holds up to 24  
Fibrlok Splices and provides superior fiber and splice  
organization. Easily installed, the tray will accommodate up  
to eight buffer tubes holding up to 48 fibers (250 m or 900  
m coated fibers) and can be adapted for fusion splice  
storage.  
7.02  
7.03  
The 2524 Splice Tray fits and mounts into the 3M 2177 Fiber  
Optic Splice Closure, the 3M 2178 Fiber Optic Splice Case  
and the 3M 2190 PST Fiber Optic Splice Closure. It is also  
compatible with a variety of non-3M closures.  
The 3M Fibrlok2505 Assembly Tool Mounting Adapter  
permits mounting of the Fibrlok Assembly Tool on standard  
3M MS2Splicing Rigs, conventional camera-type tripods,  
and other standard telco splicing rig components. The 2505  
Mounting Adapter provides the ability to mount the Fibrlok  
Assembly Tool on a variety of surfaces, and in any  
orientation, for splicing in difficult locations such as  
manholes, aerial splice points, pedestals and distribution  
frames.  
7.04  
3M Fiber Preparation Kits provide all the tools necessary for  
the assembly of the Fibrlok Splice. Fiber Splice Preparation  
Kits are available in a variety of combinations with or without  
the Fibrlok Assembly Tool and/or cleaving tool.  
Fiber Splice Preparation Kits:  
3M Stock Number  
#2530 Kit with all components listed below and Thomas & Betts Cleave Tool ..................... 80-6104-5390-6  
#2531 Kit with all components listed below............................................................................ 80-6104-5317-9  
#2533 Kit with all components listed below excluding Fibrlok Assembly Tool..................... 80-6104-5319-5  
Splice Kits Components Listing (available separately)  
Fibrlok 2501 Assembly Tool .................................................................................................... 80-6105-8187-0  
Cable Strippers ......................................................................................................................... 80-6104-4314-7  
Cleaning Alcohol Bottle ........................................................................................................... 80-6104-4329-5  
Scissors ..................................................................................................................................... 80-6104-4754-4  
No-Nik Stripper (.008) ............................................................................................................. 80-6104-4808-8  
Micro Stripper (.006)................................................................................................................ 80-6105-7250-7  
Lint Free Cloth (100/pkg.) ....................................................................................................... 80-6104-4324-6  
Magnifier, Cleaved Fiber Inspection........................................................................................ 80-6104-4799-9  
Coaxial Cable Stripper ............................................................................................................. 78-8073-7415-8  
Instruction Manual ................................................................................................................... 78-6900-1905-0  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Notice  
All statements, technical information and recommendations related to the Seller's products are based on information believed to be  
reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability  
of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use.  
Any statements or recommendations of the Seller which are not contained in the Seller's current publications shall have no force or effect  
unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all  
warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose  
which warranties are hereby expressly disclaimed.  
SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT  
LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES  
SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS THAT WERE DEFECTIVE.  
Telecom Systems Division  
6801 River Place Blvd.  
Austin, TX 78726-9000  
800/426-8688  
Printed in USA  
© 3M 1994 34-7035-4458-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Aastra Telecom IP Phone SIP9133i User Manual
Accusplit Watch 625X User Manual
Actiontec electronic Printer 802PSG User Manual
AEG Washer 86810 User Manual
Aiphone Telephone YAZ 90 3W User Manual
Air King Air Conditioner 5AU42 9215 User Manual
Aiwa Stereo System Z VR55 User Manual
American Audio CD Player MCD 810 User Manual
Atlas Sound Switch AA PPRC User Manual
Barco Automobile Accessories IP 2003 User Manual