Fan Replacement  
C4612M (10/09)  
This document describes how to replace a failed system or CPU fan in a NSM5200 Series network system manager (NSM) or a DAS5200 Series  
direct attached storage (DAS).  
MODELS  
NSM5200-FAN  
NSM5200-FANB  
DAS5200-FAN  
System fan replacement for the NSM5200  
Rear chassis fan replacement for the NSM5200  
System fan replacement for the DAS5200  
REPLACING A SYSTEM FAN  
The NSM5200 and the DAS5200 each have four system fans that are located in the middle of the unit. These fans are hot-swappable and can be replaced  
without turning the unit off and without pulling the unit completely out of the rack. A red indicator light shows the failed fan.  
NOTE: When the unit is pulled out to replace a system fan, make sure that all cables connected to the unit are long enough to avoid being disconnected.  
1. To release the unit from the rack, turn the two captive thumbscrews on the rack counterclockwise to loosen them.  
2. Gently slide the unit toward you until it stops.  
3. Remove the two screws from the appropriate system fan cover; set the screws aside.  
4. Open the system fan cover.  
5. Pinch the latches on either side of the failed fan, and pull the fan out of the slot.  
Figure 1. Replacing a System Fan  
6. Gently slide the replacement fan into the empty slot. Make sure that the latches on the new fan are engaged and the fan is seated properly.  
7. Close the system fan cover and replace the screws.  
8. Slide the NSM5200 back into the rack.  
9. Turn the captive thumbscrews clockwise to tighten them.  

Iiyama Computer Monitor PLT1900 User Manual
Intel GA 8I945GZME RH User Manual
JVC AV 29V331 User Manual
Lenovo THINKCENTRE 4498 User Manual
Magnavox MDV434 User Manual
Omega Speaker Systems VR200 User Manual
Philips 27TS54C User Manual
Philips 28PW6305 User Manual
Philips 190S7FG User Manual
Philips MDV456 User Manual