Oricom eco50 Series
DECT Digital Cordless Phone
USER GUIDE
Keep this user guide for future reference.
WARNINGS AND SAFETY INFORMATION 1
recommended that you position the base unit at least
one metre from such appliances.
IMPORTANT
• This telephone complies with applicable safety
requirements for exposure to radio waves (EMR).
The mean power of this telephone does not exceed
20mW limit at which point testing is required.
• The earpiece of the handset may attract small metal
objects such as staples and pins. Care should be
taken when placing the handset near these items.
• Avoid exposure of this telephone to moisture or liquid.
• To prevent electric shock, do not open the handset or
base cabinet.
• Avoid metallic contact (e.g. metal clips, keys) between
the battery contacts and charging conductors.
• There is a slight chance that the telephone could be
damaged by an electrical storm. It is recommended
that users unplug the phone from the mains supply
and telephone socket during a storm.
• This telephone is not designed for making emergency
telephone calls when the mains power fails.
• Always have a corded phone available to be able to
make and receive calls to emergency services if the
mains power fails.
• Do not use your telephone during an electrical storm
thunderstorm as it is possible to get an electric shock.
• Do not use the handset in an explosive hazard area
such as where there is gas leaking.
• Follow the local regulations regarding the disposal of
your packing materials, exhausted batteries and used
phone. Wherever possible, recycle those materials.
• We advise that this phone should not be used near
intensive care medical equipment or by persons with
pacemakers.
• Clean with a dry, soft, lint-free cloth. Never use cleaning
agents, particularly aggressive solvents.
• Refer to information contained in White pages directory.
• This phone is designed for connection to a PSTN
telephone line or an analogue extension port of a
PBX system. If you connect this device to a digital
extension of a PBX, damage may result to the PBX.
• Because the phone works by sending radio signals
between base station and handset, wearers of
hearing aids may experience interference in the form
of a humming noise.
• Your phone can interfere with electrical equipment
such as answering machines, TV and radio sets,
clock radios and computers if placed too close. It is
CAUTION
Use only the mains adaptors supplied with this product.
Incorrect adaptor polarity or voltage can seriously
damage the unit.
!
Adaptor for base unit and charger:
Input: 100~240VAC 50Hz/60Hz 100mA Output: 6.5VDC 200mA
2 GETTING STARTED
Installation and Charger
WARNING
1. Connect the mains adaptor (supplied)
to the socket on the back of the base
unit and to the wall mains supply.
2. Connect the telephone cord to the
phone socket on the back of the base
unit and into the wall phone socket.
DO NOT USE STANDARD/ALKALINE BATTERIES IN
THIS PRODUCT, AS THERE IS A RISK OF EXPLOSION
AND/OR INJURY. USE ONLY NI-MH RECHARGEABLE
BATTERIES AS SPECIFIED IN THIS USER GUIDE.
CONTACT ORICOM FOR REPLACEMENT BATTERIES.
!
RISK OF EXPLOSION IF BATTERY IS REPLACED BY
AN INCORRECT TYPE.
Never use non-rechargeable batteries. Use recommended
type supplied with this product.
3. Insert 2 rechargeable Ni-MH AAA
batteries (included), observing the
correct polarity, into the battery compartment on the
handset. Slide the battery door firmly into place.
• Never use alkaline or lithium batteries.
• Do not dispose of the batteries in a fire, as they can
explode.
4. Place the handset on the charging cradle and charge
the batteries for a full 15 hours before using it for the
first time.
• Do not open or mutilate the battery. Released
electrolyte is corrosive and can cause damage to the
eyes or skin. It can be toxic if swallowed.
• Avoid contact with metal objects when handling the
battery. These objects could short out the batteries or
cause the conductor to overheat resulting in burns.
Note:
It may take some time for the cordless handset to power
up, and it may get warm during initial charge. This is
normal.
• Do not attempt to recharge the battery cell by heating
it. Sudden release of battery electrolyte can cause
burns or irritation to the eyes or skin.
• Observe the proper polarity, or direction, of any battery.
Reverse insertion of the battery cell can result in
leakage or explosion.
Tip!
It is good practice to put the cordless handset on the
charging cradle when it is not in use to ensure that the
handset is always fully charged.
• Remove the batteries if you do not plan to use the
product for several months at a time.
• Follow the local regulations regarding the disposal of
your packing materials, exhausted batteries and used
phone. Wherever possible, recycle those materials.
GETTING STARTED 3
Pack contents
Purchasing additional handsets
Depending on the model you have purchased this pack You may expand your eco50 by adding more handsets
should contain the following items:
(eco5050WH). These can be purchased separately from
the retailer where you purchased the product, or directly
from Oricom (Australia). The eco50 can accommodate a
total of 5 cordless handsets.
If any of these are missing, please contact Oricom directly.
eco50-1
eco50-2
Base units
1
1
0
1
1
1
1
2
1
1
1
1
Important:
Do YoU HaVE BroaDBanD/aDSL?
If you do, you must connect an in line filter (not supplied) between
the telephone socket and your eco50 base to ensure that your
broadband and eco50 will work properly. If you do not install the filter
you will experience interference on the eco50 and your Broadband
may suffer dropouts. Please refer to the user guide of the in line filter
for installation.
Cordless handsets
Charging cradle and power adaptor
Power adaptors
Line cord
User guide
Handset Rechargeable AAA
Ni-MH Batteries (1.2V 500mAh)
2
4
ꢀ GETTING STARTED
Your cordless handset
1 Talk
2 Left / Recall / Dial mode
3 Handsfree
4 Phonebook
5 Right / CID (Caller ID)
6 Intercom
1
2
3
4
5
6
7
7 Delete / Mute
8 Numeric keys
9
/ Ringer Off (On)
*
8
10 Ringer Melody / Ringer Volume / Receiver Volume
11 # / Keypad lock
11
12
9
12 LNR (Last Number Redial) / Pause /Long (Short)
flash
10
GETTING STARTED ꢁ
Understanding the cordless handset display
Left Arrow / Phonebook records are being
reviewed
Battery level (3 bars fully charged)
Ringer is turned off
Speakerphone on
Keypad lock
Connected to telephone line
Flashes when there is an incoming call
X appears: microphone muted
Caller display
Antenna in range / out of range
Intercom call to another handset
Right Arrow / Message waiting
6 BASIC OpERATION
During standby
Answering an incoming call
When there is an incoming call, the phone rings and flashes
Note:
on the display. If a CID record is received,
caller information is displayed.
flashes and the
If the power is not connected to the base unit.
The cordless handset CANNOT operate.
1. Press [
2. Press [
] key to answer the call.
] key again to end the call.
Cordless handset's LCD display
HANDSET 1 : Handset number
: Current battery level
Making an external call
Normal dialling
: A constant signal icon indicates the
cordless handset is linked to the base unit.
When signal icon is flashing the handset
needs to be re-registered.
1. Press [
] key.
2. Enter a telephone number. If you enter more than 12
digits, you only see the last 12 digits on the display.
3. Press [
] key to end the call.
Pre-dialling
1. Enter a telephone number.
2. When necessary, press [ ] to erase the digit individually.
Note:
The signal icon will also flash if the handset is out of range.
3. Press [
4. Press [
] key to dial.
] key to end the call.
BASIC OpERATION ꢂ
Mute feature
Checking the signal strength
Place a call on hold so that the caller will NOT be able to The signal icon
displays the link status between your
hear you but you can still hear the caller.
handset and the base unit. A steady icon means your
handset and the base unit are linked. A flashing icon
means your handset and the base unit are not linked.
During talking mode,
1. Press [
] key on the handset to mute the call,
is
If you move too far away from the base unit while you are
on the phone, you will hear warning tones notifying you that
your handset is almost out of range – lost link. Take your
handset closer to the base unit or your call may be cut off
shortly after the warning
shown on the display.
2. Press [ ] key again to resume the call.
Handset range
Your eco50 handset has a range of up to 300 metres
outdoors and up to 50 metres indoors, in ideal conditions.
Note:
If your handset has lost the link with the base, you will not
be able to make or receive calls. You will also not be able
to carry out many of the phone functions and features.
If you carry the handset too far away from the base, you
may go out of communication range and the antenna icon
will flash on the display.
If you are already on a call and move out of range, the call
quality will degrade as the range limit is reached and the
call may be disconnected. You will need to move closer
to the base to be able to continue the call and make any
further calls.
Important notE:
Emergency Call. This telephone is not designed for making
emergency telephone calls when the power fails. Alternative
arrangements should be made for access to emergency services.
ꢃ BASIC OpERATION
Recall selection
Handsfree mode
You can use the Recall button on your telephone when using During talking or standby mode,
your network operator's services such as call waiting etc.
A subscription may apply for these services. Contact your
network operator for more information. If this is not working
correctly, change the setting using the instruction below:
1. Press [ ] key to switch to speakerphone mode.
2. Press [ ] key again to cancel this feature.
Volume adjustment
Selecting recall duration:
During standby mode adjust the handset ringer volume.
1. Press and hold [
] for 3 seconds.
1. Press [ ] key.
2. Press [ R/ ] or [
2. The display will show “L” or “S”
(L: New Zealand ; S: Australia).
\
] key to adjust the handset
volume level, there are 5 volume levels and Volume off
for selection.
During handset talking mode adjust the handset receiver
volume.
Press [
] key repeatedly to adjust the handset volume
level (5 volume levels).
CALLER ID OpERATION 9
If you subscribe to your telephone operators service 1. Press [ R/ ] key.You will hear a dial tone.
(charges may apply), numbers of the incoming calls will be
displayed on the screen and stored in the call log (please
consult your telephone service provider for details).
2. Press [ 2 ] to put the current call on hold and talk with
the second caller.
3. Repeat steps 1-2 to swap between the two callers.
The eco50 series can store the last 20 calls including: the
record number, date/time, and phone number (up to 24
digits for the cordless handset).
Review Caller ID records
During standby mode,
When you have new/unanswered calls,
flashes on the
cordless handset. If a call has been answered, then the call
is set to old call.
1. Press [
\
] key to display the latest call. The following
will appear on the display.
45748888
Call waiting (Australia only)
You can use the recall function to answer a second call
while you are on the phone. However this service needs to
be turned on. For example, to turn on Telstra’s Call Waiting
service:
If the list is empty, “NO” is shown on the display.
2. Press [
] key to view the data and time of the CID.
3. Press [
\
] key to view to the previous call.
1. Press [
] on the cordless handset to wait for dial tone
Press [ R/ ] key to view the next call.
then press [ ] [4] [3] [#].
Only when the network sends the time/date together with
the telephone number! On some networks with caller ID,
time and date will not be displayed.
2. You will hear a service tone then press [
] again.
Take two different calls at the same time
During a call, you will hear two loud beeps periodically to
notify you of another incoming call. If you wish to answer
this call,
10 CALLER ID OpERATION
Store a CID number
Delete CID record(s)
You can save a CID record into the Phonebook/Direct While you are viewing the CID record that you wish to
memory provided that it contains a valid phone number and delete,
the Phonebook/Direct memory is not full.
Press and hold [ ] key for about 3 seconds.
While you are viewing the CID record that you wish to save,
Note:
1. Press and hold [
] key for about 2 seconds. The
If there are no more CID records, a message “NO” is
displayed.
following will appear on the display.
_
45748888
Calling a number from the CID records
2. The space after the last digit of the CID will blink, and
press the numeric keys to edit the CID number and then
When you are viewing the CID records,
1. Press [
2. Press [
\
] or [ R/ ] key to scroll to desired number.
] key. The number will be dialled automatically.
press [
] key to confirm.
3. Press the numeric keys to edit the memory location
(0-9) where you want to store the number. If you made a
mistake, press [ ] key to edit it.
4. Press [
mode.
] key again to confirm and go back to standby
The record is now saved into the phonebook. Then it goes
back to the call log.
LNR FuNCTION (LAST NuMBER REDIAL) 11
2. The space after the last digit of the Redial number will
Redial the last number
blink, and you can press numeric keys to edit the Redial
number. Then press [ ] key to confirm.
Your cordless handset stores the last 3 external numbers
dialled, up to 24 digits per number. If the number exceeds
24 digits, the last 24 digits will be stored to memory.
3. Press the numeric keys to edit the memory location
(0-9) where you want to store the number. If you made a
mistake, press [ ] key to edit it.
During standby mode,
4. Press [
mode.
] key again to confirm and go back to standby
1. Press [
2. When necessary, press [
selected your desired number.
] key.
] key again until you have
The record is now saved into the phonebook. Then it goes
back to the call log.
3. Press [
] key to dial.
Or
Delete last number dialled
1. Press [
2. Press [
] key.
While you are viewing a previously dialled number that you
wish to delete,
] key to redial the last number.
Press and hold [ ] key for about 3 seconds.
Store the last number dialled
While you are viewing a previously dialled number that you
wish to save,
Note:
If there are no more LNR records, a message “NO” is
displayed.
1. Press and hold [
] key for about 2 seconds. The
following will appear on the display.
_
45748888
12 phONEBOOk
Add new records
Review / Edit / Dial stored Phonebook
records
You can store up to 10 phonebook records in each handset.
Each record can contain up to 24 digits per number.
During standby mode,
During standby mode,
1. Press [
] key. The following will appear on the display.
1. Press and hold [
the display.
] key until the
icon appears on
2. Press the numeric keys to enter the telephone number.
If you made a mistake, press [ ] key to edit it. Press
and hold [ ] key to delete the entire number.
2. Press the numeric keys to view the stored records.
3. Press [ ] key to dial the number.
3. Press [
] key to confirm.
4. Press the numeric keys to enter the memory location
(0-9) where you want to store the number.
5. You will hear a confirmation beep.
The record is now saved into the Phonebook. Then it goes
back to standby mode. Repeat step 1 to 5 to add another
record.
While you are viewing the record that you wish to edit,
1. Press and hold [ ] key. The following will appear on
the display The space after the last digit will blink.
.
_
245748888
2. Press [ ] key to erase the last digit, or press and hold
] key to erase the entire digits.
3. Press [ ] key to confirm.
[
CORDLESS hANDSET OpERATION 13
1. Press and hold [ ] key.
Voicemail indication – network service
2. Press [ R/ ] or [
\
] key to select the melody option
(1 to 9 for adjustment).
Note:
3. Press [ ] key to confirm.
Volcemail Indication Service. Requires subscription with
your netwok service provider.
Handset ringer volume
During standby mode,
Voicemail indication is a visual voicemail alert. On this
1. Press [ ] key. Display shows the current volume level.
2. Press [ R/ ] or [
phone, you will see an envelope
icon when there is a
\
] key to select the volume level.
voicemail waiting in your service providers mailbox.
There are 5 levels for adjustment: 1 (lowest) to 5 (highest)
and Volume off (the [
display).
3. Press [ ] key again to confirm.
] icon will be shown on the
Retrieving voicemail(s)
To retrieve your voicemail(s), consult your service provider.
Clearing the voicemail indicator
Handset ringer On / Off
During standby mode, press and hold [
between ringer On/Off.
After checking your voicemail(s), the voicemail indicator
will be cleared automatically after receiving a signal
from the network. You can clear the voicemail indicator
manually if it fails to reset.
] key to switch
1. Remove the batteries of the handset unit. Wait for 30
seconds. Insert batteries again, the voicemail indicator
will be cleared.
appears whenever the ringer is Off.
Handset ringer adjustment
Note:
Handset ringer melody
There is no ringer on the base unit.
During standby mode,
1ꢀ CORDLESS hANDSET OpERATION
2. Key the handset number (1, 2, 3, or 4) you wish to
Multi-handset Operation
transfer.
Your eco50 series phone can have up to 5 handsets
registered to the base unit. Each handset has its own number
HS-1, HS-2, HS-3, HS-4 and HS-5, shown on the left-hand
side of the display.With 2 or more handsets you can:
3. Press [
] key to exit Intercom mode and return to
standby mode.
Conference calls
This function allows 3 parties (yourself + external call +
intercom call ) to be connected at the same time.
•
•
•
•
Make intercom calls while on an external call
Switch between an external call and intercom call
Transfer an external call from one handset to another
Set a 3-way conference call between yourself, an
external call and intercom call
During external call,
1. Press [ INT ] key. The following will appear on the display.
Note:
• A maximum of 1x external call and 2x intercom calls can
take place at the same time.
• If you make an external call + another handset is on line
= result in a busy tone.
• You can make an intercom call when the other handset is
in progress.
2. Key the handset number (1, 2, 3, or 4) you wish to invite
to the conference.
3. Then you can have an intercom call with HS-x.
4. At this moment, you can press and hold [INT] key for 3
seconds to go to 3-way conference call.
Call transfer between cordless handsets
During external call,
Cordless handset keypad lock
During standby mode,
1. Press [ INT ] key. The following will appear on the display.
1. Press and hold [
] key to lock the keypad.
2. To release keypad lock, press and hold [
seconds.
] key for 3
CORDLESS hANDSET OpERATION 1ꢁ
3. Enter the base pin code (0000). If the pin is wrong, the
handset will restart searching for the base.
Note:
When the keypad is locked, [
be used to answer an external or intercom call.
] key and [ INT ] key can
4. When the handset is registered, it will show “HS”
followed by the handset number.
Note:
Registration
If the base is full and cannot add any more handsets, you
will hear a tone. See the next section to remove a handset.
Register new handsets on the eco50 base
The handsets which come in the same pack are already
registered to the base. If you buy new handsets. You need
to register them before use.
Remove handsets
During standby mode,
1. Press and hold the [
\
] key for 3 seconds, then press
1. Charge the batteries (for 15 hours).
2. Register the handset (to the base unit).
and hold the [ ] key for 3 seconds.
2. Enter the default value 0000. If the pin is wrong, the
handset will go back to standby.
3. Press the numeric keys (1-4) to enter the handset number
you want to remove.
4. The unit will go back to standby if the removal is
successful.
Each base can register up to 5 handsets.
During standby mode,
1. Press and hold the [
the [ ] and [ ] icons flash, then press and hold the
] key for 3 seconds. The following will appear on
\
] key for 3 seconds until both
[
the display.
Note:
You can only remove other handsets in your system but
you are not able to remove the handset you are using.
2. Press 1 and the handset begins to search for the base.
16 AppENDIx
Troubleshooting
Problem
Possible cause(s)
Solution(s)
No dial tone on the
cordless handset.
1. The base unit is not properly connected.
2. Too far from the base unit.
3. Battery charge is low.
1. Check CONNECTION to power and telephone line.
2. Move handset CLOSER to base unit.
3. CHARGE battery.
4. Incorrect battery polarity.
5. Re-register handset.
4. RE-INSERT batteries and check + and .
5. Handset not registered.
Antenna symbol is
flashing.
1. The handset is not registered. If the handset 1. REGISTER the handset.
is unregistered, it displays UNREGISTERED.
2. Move CLOSER to the base unit.
2. The handset is out of range.
3. Check power CONNECTION to the base.
3. The product is not properly connected.
No beep when the
cordless handset is
placed on the charger.
1. The handset is not placed properly on the
charger.
2. Charging contacts are dirty.
3. No power connection to base unit.
4. The handset’s power is turned off.
1. Lift handset off the charger carefully and REPOSITION
correctly.
2. CLEAN charging contacts with a clean and dry cloth.
3. Check power CONNECTION to the base.
4. CHECK batteries.
Handset charged for 24 1. Handset battery is defective or faulty.
1. REPLACE with new AAA rechargeable Ni-MH
batteries.
2. CHECK to make sure the battery icon is scrolling.
3. RE-INSERT batteries and check + and .
4.Check power CONNECTION to the base.
hours but Battery icon
remains empty.
2. Handset is not placed properly on the
charger.
3. Battery installed incorrectly.
4. The product is not properly connected.
AppENDIx 1ꢂ
Problem
Possible cause(s)
1. Battery is empty.
2. The product is not properly connected.
1. Interference from nearby electrical appliance. 1. Try a different connection point, one that is away from
Solution(s)
No symbol on the
display.
1. CHARGE battery.
2. Make sure your product is properly PLUGGED-IN.
Bad audio quality
(crackles,echo, etc.).
other electrical appliances.
2. Install the base unit in a DIFFERENT room OR use
EXTENSION leads.
2. Base unit is installed in a room with thick
walls.
3. The handset is too far from the base unit.
3. Move CLOSER to the base unit.
4. Ensure a in-line ADSL filter is installed on all phone
sockets between wall plate and your phone.
4. If you have Broadband/ADSL you need a in
line filter (not supplied).
Caller ID does not work. Service not activated.
Check your SUBSCRIPTION with the SERVICE provider.
Phone does not ring
when a call comes in.
1. The ringer is off.
2. Too many phones are sharing the same
phone line.
1. Turn ON the ringer.
2. Disconnect some of the phones from the phone line.
3. Check base unit CONNECTIONS.
3. Base unit not plugged in.
Keypad does not work.
Keypad may be locked.
UNLOCK the keypad.
Busy tone + in use light 1. Other handset may still be connected.
1. Check ALL handsets and END all calls.
2. Check CONNECTIONS to wall and base.
on.
2. Check power supply connection.
Can’t transfer a call.
1. Handset is busy.
2. Handset is out of range.
3. Wrong handset number.
1. Check ALL handsets and END all calls.
2. Move handset CLOSER to base unit.
3. Check HANDSET NUMBER.
Handset registration
fails continuously.
The base memory may be full.
Delete un-used handset and try again.
1ꢃ AppENDIx
Problem
Possible cause(s)
2nd call service can be activated.
Solution(s)
Cannot make/answer a
2nd call
Check with your service provider. Check the recall
selection is correct.
Note:
If none of the above solutions help, reset your phone by disconnecting the mains power from the base and removing batteries
from handset/s. Reconnect after 15 minutes.
Alternatively please contact Customer Service on 1300 889 785.
AppENDIx 19
Product Specifications
Phone – Oricom eco50
Frequency range
Channel bandwidth
Operating range
Specifications
1.88-1.897 GHz (bandwidth=20MHz)
1.728 MH
Up to 300m outdoors, up to 50m indoors
Up to 100 hours
Standby time
Talk time
Up to 10 hours
Temperature time
Operating 0ºC to 40ºC
Storage -20ºC to 60ºC
Compatibility
Only GAP compatible DECT phones
Up to 5 handsets per base
Up to 4 bases per handset
5 polytones + 4 monotones only
Multiple handset capability
Multiple bases
Ringer melodies
Included Accessories
Battery charge time
15 hours
Rechargeable batteries
AAA Ni-MH 1.2V 500mAh
Mains power supply for base unit and charger
Input: 100~240VAC 50Hz/60Hz 100mA; Output: 6.5VDC, 200mA
20 AppENDIx
(iii) any un-controlled external cause to the phone not
functioning including but not limited to electricity
failure, lighting, over voltage;
(iv) non adherence by you to the warnings in the User
Guide and the User Guide generally;
(v) modification to the product or services carried out
to the product by anyone other than Oricom or on
Oricom’s behalf.
Warranty Information (Australia)
(a) Warranty
Oricom warrants that the product is free from defects in
materials and workmanship for a period of 12 months
effective from the date of purchase. This warranty in
no way affects your statutory warranty under the Trade
Practices Act 1974 or any other similar legislation. It is
important that you read the Warranty Card as it contains
full and additional details of the warranty, limitation
of warranty and conditions for receiving the warranty
services during the warranty period. The Warranty
Card is located in the package. If you cannot locate the
Warranty Card, please contact our Customer Support
Service on 1300 889 785.
Oricom will not be liable for consequential losses including
loss of profits arising from a cause of action in contract, tort
or any other statutory or common law (except where a statute
or any law prohibits this exclusion). The warranty does not
extend to damage caused by misuse, negligence, excessive
voltage, faults on the telephone line or lightning. This warranty
in no way affects your statutory rights. Full details of the
warranty are contained in the enclosed warranty card.
(b)Exclusion and limitation of liability.
Oricom will not be in breach of a warranty or condition
expressly stated in this User Guide or the Warranty
Card or implied by the Trade Practices Act and excludes
any liability arising under any statutory or common law
for damages or any other remedy if the damage occurs
as a result of:
(i) failure by you to follow the instructions in the User
Guide for the installation and proper functioning of
the product;
(ii) negligence on your part or misuse by you of the
product;
CuSTOMER SuppORT 21
If you feel this product is not working correctly please To order spare parts additional handsets, replacement
consult the user guide and ensure that you are using the batteries and in case of any technical issues you may have
product in accordance with the instructions. Remove all with this product please consult our website for further
extra telephone equipment and connect only this telephone information or send us an email for a prompt response to
directly to the telephone socket. If the fault is still present, your enquiry.
connect another telephone (if available) to the telephone
In the unlikely event of a fault developing, please contact us
socket. The results will show you whether the fault lies with
for assistance. If the product is then found to be faulty you
this unit or with the telephone line.
will be asked to return it directly to us with a copy of the
If the product is working correctly the fault is on the purchase receipt.
telephone line. Please contact your network operator for
assistance.
Australia
New Zealand
Oricom International Pty Ltd
Locked Bag 658
Atlas Gentech (NZ) Limited
Private Bag 14927
South Windsor, NSW 2756
Panmure, Auckland
Customer Support
Email: [email protected]
Phone: 1300 889 785
Customer Support
Email: [email protected]
Phone: 0900 50 025 (Toll Call)
Fax: (09) 574 2722
Fax: (02) 4574 8898
|