External Control
NEC LCD Monitor
1. Application
Thisdocumentdefines thecommunicationsmethodfor controlofthe NECLCDmonitor, MultiSyncX461UN
/X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461 /M521 when using
an external controller
.
2. Connectors and wiring
2.1 RS-232C Remote control
Connector: 9-pin D-Sub
Cable: Cross (reversed) cable or null modem cable
(Please refer “Controlling the LCD monitor via RS-232C Remote control” on User’s manual.)
2.2 LAN control
Connector: RJ-45 10/100 BASE-T
Cable: Category 5 or higher LAN cable
(Please refer “Controlling the LCD monitor via LAN control” on User’s manual.)
3. Communication Parameter
3.1 RS-232C Remote control
(1) Communication system
(2) Interface
Asynchronous
RS-232C
9600bps
8bits
(3) Baud rate
(4) Data length
(5) Parity
None
(6) Stop bit
1 bit
(7) Communication code
ASCII
3.2 LAN control
(1) Communication system
(2) Interface
TCP/IP (Internet protocol suite)
Ethernet (CSMA/CD)
(3) Communication layer
Transport layer (TCP)
* Using the payload of TCP segment.
(Default) 192.168.0.10
(4) IP address
* If you need to change,
Please refer “Network settings” on User’s manual.
7142 (Fixed)
(5) Port No.
(Note)
The monitor will disconnect the connection if no packet data is received for 15 minutes.
And the controller (PC) has to re-connect to control the monitor again, after 15 minutes or more.
3.3 Communication timing
The controller should wait for a packet interval before next command is sent.
The packet interval needs to be longer than 600msec for the LCD monitor.
(1/50)
2ndbyte) Reserved: Reserved for future extensions.
On this monitor, it must be ASCII '0'(30h).
3rdbyte) Destination: Destination equipment ID. (Receiver)
Specify a commands receiver’s address.
The controller sets the “MONITOR ID” or “GROUP ID” of the monitor controlled in here.
On the reply, the monitor sets ‘0’ (30h), always.
“MONITOR ID”, “GROUP ID” to “Destination Address” conversion table is as follows,
Monitor
ID
Destination
Address
Monitor
ID
Destination
Address
Monitor
ID
Destination
Address
Monitor
ID
Destination
Address
1
2
3
4
5
6
7
8
41h(‘A’)
42h(‘B’)
43h(‘C’)
44h(‘D’)
45h(‘E’)
46h(‘F’)
47h(‘G’)
48h(‘H’)
49h(‘I’)
4Ah(‘J’)
4Bh(‘K’)
4Ch(‘L’)
4Dh(‘M’)
4Eh(‘N’)
4Fh(‘O’)
50h(‘P’)
51h(‘Q’)
52h(‘R’)
53h(‘S’)
54h(‘T’)
55h(‘U’)
56h(‘V’)
57h(‘W’)
58h(‘X’)
59h(‘Y’)
2Ah(‘*’)
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
5Ah(‘Z’)
5Bh
5Ch
5Dh
5Eh
5Fh
60h
61h
62h
63h
64h
65h
66h
67h
68h
69h
6Ah
6Bh
6Ch
6Dh
6Eh
6Fh
70h
71h
72h
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
73h
74h
75h
76h
77h
78h
79h
7Ah
7Bh
7Ch
7Dh
7Eh
7Fh
80h
81h
82h
83h
84h
85h
86h
87h
88h
89h
8Ah
8Bh
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
8Ch
8Dh
8Eh
8Fh
90h
91h
92h
93h
94h
95h
96h
97h
98h
99h
9Ah
9Bh
9Ch
9Dh
9Eh
9Fh
A0h
A1h
A2h
A3h
A4h
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
ALL
Group
ID
Destination
Address
Group
ID
Destination
Address
Group
ID
Destination
Address
Group
ID
Destination
Address
A
B
C
31h(‘1’)
32h(‘2’)
33h(‘3’)
D
E
F
34h(‘4’)
35h(‘5’)
36h(‘6’)
G
H
I
37h(‘7’)
38h(‘8’)
39h(‘9’)
J
3Ah(‘:’)
Ex.) If you want to control a monitor that has the "ID No." as '1', specify a destination address
'A'(41h). If you want to control all of the monitors which are connected by a daisy chain, specify
a destination address ‘
*’(2Ah).
4thbyte) Source: Source equipment ID. (Sender)
Specify a sender address.
The controller must be ‘0’ (30h).
On the reply, the monitor sets the own MONITOR ID in here.
(3/50)
5thbyte) Message Type: (Case sensitive.)
Refer to section 4.2 “Message block format” for more details.
ASCII 'A' (41h): Command.
ASCII 'B' (42h): Command reply.
ASCII 'C' (43h): Get current parameter from a monitor.
ASCII 'D' (44h): "Get parameter" reply.
ASCII 'E' (45h): Set parameter.
ASCII 'F' (46h): "Set parameter" reply.
6th -7th bytes) Message Length:
Specify the length of the message (that follows the header) from STX to ETX.
This length includes STX and ETX.
The byte data must be encoded to ASCII characters.
Ex.) The byte data 3Ah must be encoded to ASCII characters '3' and 'A' (33h and 41h).
The byte data 0Bh must be encoded to ASCII characters '0' and 'B' (30h and 42h).
4.2 Message block format
Message
Header
Check code
Delimiter
“Message block format” is allied to the “Message Type” in the “Header”.
Refer to the section 6 “Message format” for more detail.
1
)Get current parameter
The controller sends this message when you want to get the status of the monitor.
For the status that you want to get, specify the “OP code page” and “OP code”,
refer to “Appendix A. Operation code table”.
“Message format” of the “Get current parameter” is as follows,
OP code page
Hi Lo
OP code
Hi
STX
ETX
Lo
Refer to section 5.1 “Get current parameter from a monitor.” for more details.
2
)
Get Parameter reply
The monitor will reply with the status of the requested item specified by the controller
in the “Get parameter message”.
“Message format” of the “Get parameter reply” is as follows,
OP code
page
Result
Lo
OP code
Hi Lo
Type
Hi
Max value
LSB
Current Value
MSB LSB
STX
ETX
Hi
Hi
Lo
Lo
MSB
Refer to section 5.2 “Get parameter reply” for more details.
3
)
Set parameter
The controller sends this message to change a setting of the monitor.
(4/50)
Message format of the “Set parameter” is as follows,
OP code
page
OP code
Hi Lo
Set Value
MSB
STX
ETX
Hi
Lo
LSB
Refer to section 5.3 “Set parameter” for more details.
4
)
Set Parameter reply
The monitor replies with this message for a confirmation of the “Set parameter message”.
Message format of the “Set parameter reply” is as follows,
OP code
page
Requested setting
Value
Result
OP code
Hi Lo
Refer to section 5.4 “Set parameter reply” for more details.
Type
Max value
ETX
STX
Hi
Lo
Hi
Lo
Hi
Lo
MSB
LSB
MSB
LSB
5
)
Command
“Command message” format depends on each command.
Usually, this “command message” is used for some non-slider controls and some special operations,
such as “Save current settings”, “Get timing report”, “power control”, “Schedule”, etc. Refer to
section 5.5 “Commands message” for more details.
6
)
Command reply
The monitor replies to a query from the controller.
“Command reply message” format depends on each command.
Refer to section 5.5 “Commands message” for more details.
Check code
Header Message
Delimiter
4.5 Check code
Check code is the Block Check Code (BCC) between the Header and the End of Message except SOH.
27
26
25
24
23
22
21
20
SOH
D0
D1
D2
D3
D4
D5
D6
D7
D8
|
Reserved
Destination
Source
Type
Length(H)
Length(L)
STX
Data
|
|
|
ETX
Check code
Dn
Dn+1
P
P
P
P
P
P
P
P
Dn+1 = D1 XOR D2 XOR D3 XOR ,,, Dn
XOR: Exclusive OR
(5/50)
Following is an example of a Check code (BCC) calculation.
Header
Message
OP code
Check
code
(BCC)
Delimiter
Destination
Address
Source
Address
Message
type
OP code
page
SOH Reserved
Message length
STX
Set Value
ETX
01
D0
30
D1
41
D2
30
D3
45
D4
30
D5
41
D6
02
D7
30 30 31 30 30 30 36 34
D8 D9 D10 D11 D12 D13 D14 D15
03
77
0D
D16
D17
D18
Check code (BCC) D17 = D1 xor D2 xor D3 xor … xor D14 xor D15 xor D16
= 30h xor 41h xor 30h xor 45h xor 30h xor 41h
xor 02h xor 30h xor 30h xor 31h xor 30h xor 30h
xor 30h xor 36h xor 34h xor 03h
= 77h
Delimiter
Header Message Check code
4.6 Delimiter
Packet delimiter code; ASCII CR(0Dh).
(6/50)
5. Message type
5.1 Get current Parameter from a monitor.
OP code page
Hi Lo
2nd-3rd
OP code
Hi
STX
1st
ETX
6th
Lo
4th–5th
Send this message when you want to get the status of a monitor.
For the status that you want to get, specify the “OP code page” the “OP code”, refer to “Appendix
A. Operation code table”.
1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) OP code page: Operation code page.
Specify the “OP code page” for the control which you want to get the status.
Refer to “Appendix A Operation code table” for each item.
OP code page data must be encoded to ASCII characters.
Ex.) The byte data 02h must be encoded to ASCII characters '0' and '2' (30h and 32h).
OP code page 02h -> OP code page (Hi) = ASCII '0' (30h)
OP code page (Lo) = ASCII '2' (32h)
Refer to Operation code table. (Appendix A)
4th–5thbytes) OP code: Operation code
Refer to “Appendix A Operation code table” for each item.
OP code data must be encoded to ASCII characters.
Ex.) The byte data 3Ah must be encoded to ASCII characters '3' and 'A' (33h and 41h).
OP code 3Ah ->
OP code (Hi) = ASCII '3' (33h)
OP code (Lo) = ASCII 'A' (41h)
Refer to Operation code table.
6thbyte) ETX: End of Message
ASCII ETX (03h)
5.2 "Get parameter" reply
Result
2nd-3rd
OP code page
OP code
Type
Lo
8th -9th
Max value
10th -13th
Current Value
MSB LSB
STX
1st
ETX
Hi
Lo
Hi
Lo
Hi
Lo
Hi
MSB
LSB
4th–5th
6th –7th
14th -17th
18th
The monitor replies with a current value and the status of the requested item (operation code).
1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) Result code.
(7/50)
These bytes indicate a result of the requested commands as follows,
00h: No Error.
01h:Unsupportedoperationwiththismonitororunsupportedoperationundercurrentcondition.
This result code from the monitor is encoded to ASCII characters.
Ex.) The byte data 01h is encoded to ASCII character '0' and '1' (30h and 31h).
4th–5thbytes) OP code page: Operation code page.
These bytes indicate a replying item's OP code page.
This returned value from the monitor is encoded to ASCII characters.
Ex.) The byte data 02h is encoded to ASCII character '0' and '2' (30h and 32h).
Refer to the operation code table.
6th –7thbytes) OP code: Operation code
These bytes indicate a replying item's OP code.
This returned value from the monitor is encoded to ASCII characters.
Refer to the operation code table.
Ex.) The byte data 1Ah is encoded to ASCII character '1' and 'A' (31h and 41h).
8th -9thbytes) Type: Operation type code
00h: Set parameter
01h: Momentary
Like the Auto Setup function which automatically changes the parameter.
This returned value from the monitor is encoded to ASCII characters.
Ex.) The byte data 01h is encoded to ASCII character '0' and '1' (30h and 31h).
10th-13thbytes) Max. value: Maximum value which monitor can accept. (16bits)
This returned value from the monitor is encoded to ASCII characters.
Ex.) '0','1','2' and '3' means 0123h (291)
14th -17thbytes) Current Value: (16bits)
This returned value from the monitor is encoded to ASCII characters.
Ex.) '0','1','2' and '3' means 0123h (291)
18thbyte) ETX: End of Message
ASCII ETX (03h)
5.3 Set parameter
OP code page
Hi Lo
2nd-3rd
OP code
Hi Lo
4th-5th
Set Value
LSB
STX
1st
ETX
MSB
6th-9th
10th
Send this message to change monitor’s adjustment and so on.
The controller requests a monitor to change value.
1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) OP code page: Operation code page
(8/50)
This OP code page data must be encoded to ASCII characters.
Ex.) The byte data 02h must be encoded to ASCII '0' and '2' (30h and 32h).
Refer to the Operation code table.
4th-5thbytes) OP code: Operation code
This OP code data must be encoded to ASCII characters.
Ex.) OP code 1Ah ->
OP code (Hi) = ASCII '1' (31h)
OP code (Lo) = ASCII 'A' (41h)
Refer to the Operation code table.
6th-9thbytes) Set value: (16bit)
This data must be encoded to ASCII characters.
Ex.) 0123h ->
1st(MSB) = ASCII '0' (30h)
2nd = ASCII '1' (31h)
3rd = ASCII '2' (32h)
4th(LSB) = ASCII '3' (33h)
10thbyte) ETX: End of Message
ASCII ETX (03h)
5.4 "Set parameter" reply
Requested setting
Value
Result
Hi Lo
2nd-3rd
OP code page
OP code
Hi Lo
6th-7th
Type
Lo
8th-9th
Max value
10th-13th
STX
1st
ETX
Hi
Lo
Hi
MSB
LSB
MSB
LSB
4th-5th
14th -17th
18th
The Monitor echoes back the parameter and status of the requested operation code.
1stbyte) STX: Start of Message
ASCII STX (02h)
2nd-3rdbytes) Result code
ASCII '0''0' (30h, 30h): No Error.
ASCII '0''1' (30h, 31h): Unsupported operation with this monitor or unsupported operation under
current condition.
4th-5thbytes) OP code page: Echoes back the Operation code page for confirmation.
Reply data from the monitor is encoded to ASCII characters.
Ex.) OP code page 02h ->
OP code page = ASCII '0' and '2' (30h and 32h)
Refer to Operation code table.
6th-7thbytes) OP code: Echoes back the Operation code for confirmation.
Reply data from the monitor is encoded to ASCII characters.
Ex.) OP code 1Ah ->
OP code (Hi) = ASCII '1' (31h)
OP code (Lo) = ASCII 'A' (41h)
Refer to Operation code table
8th-9thbytes) Type: Operation type code
(9/50)
ASCII '0''0' (30h, 30h): Set parameter
ASCII '0''1' (30h, 31h): Momentary
Like Auto Setup function, that automatically changes the parameter.
10th-13thbytes) Max. value: Maximum value that monitor can accept. (16bits)
Reply data from the monitor is encoded to ASCII characters.
Ex.) '0''1''2''3' means 0123h (291)
14th -17thbytes) Requested setting Value: Echoes back the parameter for confirmation. (16bits)
Reply data from the monitor is encoded to ASCII characters.
Ex.) '0''1''2''3' means 0123h (291)
18thbyte) ETX: End of Message
ASCII ETX (03h)
5.5 Commands
"Command message format" depends on each command
.
Some commands are shown with usage. Refer to
section 7 to 13.
5.5.1 Save Current Settings.
The controller requests for the monitor to store the adjusted value.
Command code
STX
ETX
'0'
'C'
Send "OC"(30h, 43h) as Save current settings command.
Complete "Save Current setting" command packet as follows;
ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-43h-03h-CHK-0Dh
SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'C'-ETX-CHK- CR
The monitor replies the packet for confirmation as follows;
SOH-'0'-'0'-'A'-'B'-'0'-'6'-STX-'0'-'0'-'0'-'C'-ETX-CHK- CR
5.5.2 Get Timing Report and Timing reply.
The controller requests the monitor to report the displayed image timing.
Command code
STX
ETX
'0'
'7'
Send "07"(30h, 37h) as Get Timing Report command.
Complete "Get Timing Report" command packet as follows;
ASCII: 01h-30h-41h-30h-41h-30h-34h-02h-30h-37h-03h-CHK-0Dh
SOH-'0'-'A'-'0'-'A'-'0'-'4'-STX-'0'-'7'-ETX-CHK- CR
The monitor replies status as the following format;
Command
'4' 'E'
SS
H Freq.
V Freq.
STX
ETX
Hi
Lo
MSB
LSB
MSB
LSB
SS: Timing status byte
Bit 7 = 1: Sync Frequency is out of range.
Bit 6 = 1: Unstable count
(10/50)
Bit 5-2
Bit 1
Reserved (Don't care)
1:Positive Horizontal sync polarity.
0:Negative Horizontal sync polarity.
1:Positive Vertical sync polarity.
0:Negative Vertical sync polarity.
Bit 0
H Freq: Horizontal Frequency in unit 0.01kHz
V Freq: Vertical Frequency in unit 0.01Hz
Ex.) When H Freq is '1''2''A''9' (31h, 32h, 41h, 39h), it means 47.77kHz.
5.5.3 NULL Message
Command code
STX
ETX
'B' 'E'
The NULL message returned from the monitor is used in the following cases;
A timeout error has occurred. (The default timeout is 10sec.)
The monitor receives an unsupported message type.
The monitor detects a packet BCC (Block Check Code) error.
To tell the controller that the monitor does not have any answer to give to the host (not
ready or not expected)
Following operations need a certain time for to execute, so the monitor will return
this message when another message is received during execution.
Power ON, Power OFF, Auto Setup, Input, PIP Input, Auto Setup and Factory reset.
Complete "NULL Message" command packet as follows;
01h-30h-30h-41h-42h-30h-34h-02h-42h-45h-03h-CHK-0Dh
SOH-'0'-'0'-'A'-'B'-'0'-'4'-STX-'B'-'E'-ETX-CHK- CR
6. Typical procedure example
Thefollowingisasampleofprocedurestocontrolthemonitor,theseareexamplesof"Getparameter",
"Set parameter" and "Save current settings".
6.1. How to change the “Brightness” setting.
Step1.ThecontrollerrequeststheMonitortoreplywiththecurrentbrightnesssettingandcapability
to support this operation. (Get parameter)
Header
Message
STX-'0'-'0'-'1'-'0'-ETX
Check code
BCC
Delimiter
SOH-'0'-Monitor ID-'0'-'C'-'0'-'6'
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message type is "Get parameter command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the OP code page 0).
ETX (03h): End of Message
(11/50)
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step2.ThemonitorreplieswithcurrentBrightnesssettingandcapabilitytosupportthisoperation.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'
STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'
-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 100(0064h).
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Brightness setting is 50(0032h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 3. The controller request the monitor to change the Brightness setting
Check
code
BCC
Header
Message
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'E'-'0'-'A'
STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller .
'E' (45h): Message Type is "Set parameter command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Set Brightness setting 80(0050h).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
(12/50)
CR (0Dh): End of packet
Step 4. The monitor replies with a message for confirmation.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'- Monitor ID -'F'-'1'-'2'
STX-'0'-'0'-'0'-'0'-'1'-'0'—'0'-'0'-'0'
-'0'-'6'-'4'-'0'-'0'-'5'-'0'-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'F' (46h): Message Type is "Set parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 100(0064h).
'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Received a Brightness setting was 80(0050h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Repeat Step 1 and Step 2, if you need to check the Brightness setting. (Recommended)
Step 5. Request the monitor to store the Brightness setting. (Save Current Settings Command)
Header
Message
STX-'0-'C'-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'0'-'4'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to store the setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'4' (30h, 34h): Message length is 4 bytes.
Message
STX (02h): Start of Message
'0'-'C' (30h, 43h): Command code is 0Ch as "Save current settings".
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
6.2. How to read the measurement value of the built-in temperature sensors.
MultiSync X461UN /X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461
/M521 have three built-in temperature sensors.
The controller can monitor inside temperatures by using those sensors with external control.
(13/50)
The following shows the procedure for reading the temperatures from the sensors.
Step 1. Select a temperature sensor which you want to read.
Check
code
BCC
Header
Message
Delimiter
CR
SOH-'0'-MonitorID-'0'-'E'-'0'-'A'
STX-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'1'-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'E' (45h): Message Type is "Set parameter command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'8' (37h, 38h): Operation code is 78h (on page 2).
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Select the temperature sensor #1 (01h).
00h: No meaning
01h: Sensor #1
02h: Sensor #2
03h: Sensor #3
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies for confirmation.
Check
code
BCC
Header
Message
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'F'-'1'-'2'
STX-'0'-'0'-'0'-'2'-'7'-'8'-'0'-'0'-'0'-'0'
-'0'-'3'-'0'-'0'-'0'-'1'-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicates a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'F' (46h): Message Type is "Set parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'8' (37h, 38h): Operation code is 78h (in the page 2).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of temperature sensors are 3 (0003h).
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): temperature sensor is #1.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
(14/50)
Delimiter
CR (0Dh): End of packet
Step 3. The controller requests the monitor to send the temperature from the selected sensor.
Header
Message
STX-'0'-'2'-'7'-'9'-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'C'-'0'-'6'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message Type is "Get parameter".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 4. The monitor replies a temperature of selected sensor.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'
STX-'0'-'0'-'0'-'2'-'7'-'9'-'0'-'0'
-'F'-'F'-'F'-'F'-'0'-'0'-'3'-'2'-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'2' (30h, 32h): Operation code page number is 2.
'7'-'9' (37h, 39h): Operation code is 79h (in the page 2).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'F'-'F'-'F'-'F' (46h, 46h, 46h, 46h): Maximum value.
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): The temperature is 25 degrees Celsius.
Readout value is 2's complement.
Readout value
Binary
Temperature[Celsius]
Hexadecimal
00FAh
0032h
0001h
0000h
FFFFh
FFCEh
FF92h
+125.0
+ 25.0
+ 0.5
0
- 0.5
- 25.0
- 55.0
0000 0000 1111 1010
0000 0000 0011 0010
0000 0000 0000 0001
0000 0000 0000 0000
1111 1111 1111 1111
1111 1111 1100 1110
1111 1111 1001 0010
ETX (03h): End of Message
(15/50)
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
7. Power control procedure
7.1 Power status read
1) The controller requests the monitor to reply a current power status.
Header
Message
STX-'0'-'1'-'D'-'6'-ETX
Check code
BCC
Delimiter
SOH-'0'-Monitor ID-'0'-'A'-'0'-'6'
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message Type is "Command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'1'-'D'-'6': Get power status command.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor returns with the current power status.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'1'-'2'
STX-'0'-'2'-'0'-'0'-'D'-'6'-'0'-'0'-'0'
-'0'-'0'-'4'-'0'-'0'-'0'-'1'-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message Type is "Command reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX(02h):Start of Message
'0'-'2' (30h, 32h): Reserved data
'0'-'0' (30h, 30h): Result code
00: No Error.
01: Unsupported.
'D'-'6'(44h, 36h): Display power mode code
'0'-'0' (30h, 30h): Parameter type code is "Set parameter".
'0'-'0'-'0'-'4' (30h, 30h, 30h, 34h): Power mode is 4 types.
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Current power mode
<Status>
(16/50)
0001: ON
0002: Stand-by (power save)
0003: Suspend (power save)
0004: OFF (same as IR power off)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
7.2 Power control
1) The controller requests the monitor to control monitor power.
Header
Message
Checkcode
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'0'-'C'
STX-'C'-'2'-'0'-'3'-'D'-'6'-
'0'-'0'-'0'-'1'-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'C (30h, 43h): Message length is 12 bytes.
Message
STX (02h): Start of Message
'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control command
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode
0001: ON
0002, 0003: Do not set.
0004: OFF (same as the power off by IR)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
SOH-'0'-'0'-Monitor
ID-'B'-'0'-'E'
Message
Check ode
BCC
Delimiter
CR
STX-'0'-'0'-'C'-'2'-'0'-'3'-'D'-'6'-
'0'-'0'-'0'-'1'-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'N'-'N': Message length
Note.) The maximumdata length that can be written to the monitorat atime is 32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
(17/50)
'0'-'0' (30h, 30h): Result code. No error.
'C'-'2’,'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h): power control reply command
The monitor replies same as power control command to the controller.
'0'-'0'-'0'-'1' (30h, 30h, 30h, 31h): Power mode
0001: ON
0002, 0003: Do not set.
0004: OFF (same as the power off by IR)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
8. Asset Data read and write
MultiSync X461UN /X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461
/M521 have the area for to store user’s asset data of up to 64bytes.
8.1 Asset Data Read Request and reply
This command is used in order to read Asset Data.
1) The controller requests the monitor to reply with Asset data.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'0'-'A'
STX-'C'-'0'-'0'-'B'-'0'-'0'-'2'-'0'-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get data.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A' (30h, 41h): Message length is 10 bytes.
Message
STX (02h): Start of Message
'C'-'0'-'0'-'B' (43h, 30h, 30h, 42h): Asset read request command.
'0'-'0' (30h, 30h): Offset data from top of the Asset data.
At first set 00h: Read data from the top of Asset data area.
'2'-'0' (32h, 30h): Read out data length is 32bytes.
Secondly set 20h: Read data from the 32bytes offset point in the Asset data area.
Maximum readout length is 32bytes at a time.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Asset data to the controller.
Header
Message
STX-'C'-'1'-'0'-'B'-
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-N-N
Data(0)-Data(1)---Data(N)-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
(18/50)
'B' (42h): Message type is "Command reply"
N-N: Message length
Ex.) The byte data 20h is encoded to ASCII characters '2' and '0' (32h and 30h).
Note.) This length includes STX and ETX.
Message
STX (02h): Start of Message
'C'-'1'-'0'-'B' (43h, 31h, 30h, 42h): Asset read reply command
Data(0) – Data(N): Retuned Asset data
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
8.2 Asset Data write
This command is used in order to write Asset Data.
1) The controller requests the monitor to write Asset data.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-N-N
STX-'C'-'0'-'0'-'E'-'0'-'0'-
Data(0)-Data(1)---Data(N)-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID in which you want to write data.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
N-N: Message length
Note.) The maximumdata length that can be written to the monitorat a time is 32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h): Asset Data writes command
'0'-'0'(30h, 30h): Offset address from top of Asset data.
00h : Write data from top of the Asset data area.
Data(0) –- Data(N): Asset data. The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-MonitorID-'B'-N-N
STX-'0'-'0'-'C'-'0'-'0'-'E'-'0'-'0'-
Data(0)-Data(1)---Data(N)-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
(19/50)
Note.) The maximumdata length that can be written to the monitorat a time is 32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (34h and 30h).
Message
STX (02h): Start of Message
'0'-'0': Result code. No error.
'C'-'0'-'0'-'E' (43h, 30h, 30h, 45h): Asset Data write command
'0'-'0'(30h, 30h): Offset address from top of Asset data.
00h : Write data into from top of the Asset data area.
Data(0) –- Data(N): Asset data. The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
9. Date & Time read and write
9.1 Date & Time Read
This command is used in order to read the setting of Date & Time.
1) The controller requests the monitor to reply with the Date & Time.
Header
SOH-'0'-Monitor
Message
STX-'C'-'2'-'1'-'1'-ETX
Checkcode
BCC
Delimiter
CR
ID-'0'-'A'-'0'-'6'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'1' (43h, 32h, 31h, 31h): Date & time read request command.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Date & Time to the controller.
Header
Message
STX-'C'-'3'-'1'-'1'-YY-MM-DD-WW-HH-MN
-DS-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'1'-'4'
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller
Monitor ID: Indicate a replying Monitor ID
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply"
'1'-'4'(31h, 34h): Message length
Message
STX (02h): Start of Message
(20/50)
'C'-'3'-'1'-'1' (43h, 33h, 31h, 31h): Date & Time read reply command
'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data
YY: Year (offset 2000)
'0'-'0'(30h, 30h): 2000
|
'6'-'3'(36h, 33h): 2099 (99 = 63h)
MM: Month
'0'-'1'(30h, 31h): January
|
'0'-'C'(30h, 43h): December
DD: Day
'0'-'1'(30h, 31h): 1
|
'1'-'E'(31h, 45h): 30(=1Eh)
'1'-'F'(31h, 46h): 31(=1Fh)
WW: weekdays
'0'-'0'(30h, 30h): Sunday
'0'-'1'(30h, 31h): Monday
'0'-'2'(30h, 32h): Tuesday
'0'-'3'(30h, 33h): Wednesday
'0'-'4'(30h, 34h): Thursday
'0'-'5'(30h, 35h): Friday
'0'-'6'(30h, 36h): Saturday
HH: Hours
'0'-'0'(30h, 30h): 0
|
'1'-'7'(31h, 37h): 23 (=17h)
MN: Minutes
'0'-'0'(30h, 30h): 0
|
'3'-'B' (33h, 42h): 59 (=3Bh)
DS: Daylight saving (Summer time)
'0'-'0'(30h, 30h): NO
'0'-'1'(30h, 31h): YES
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
9.2 Date & Time Write
This command is used in order to write the setting of the Date & Time.
1) The controller requests the monitor to write Date & Time.
Header
Message
STX-'C'-'2'-'1'-'2'-YY-MM-DD-WW-HH-MN
-DS-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'1'-'2'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change the setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'2'(31h, 32h): Message length
(21/50)
Message
STX (02h): Start of Message
'C'-'2'-'1'-'2' (43h, 32h, 31h, 32h): Date & Time write command
'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data
YY: Year (offset 2000)
'0'-'0'(30h, 30h): 2000
|
'6'-'3'(36h, 33h): 2099 (99 = 63h)
MM: Month
'0'-'1'(30h, 31h): January
|
'0'-'C'(30h, 43h): December
DD: Day
'0'-'1'(30h, 31h): 1
|
'1'-'E'(31h, 45h): 30(=1Eh)
'1'-'F'(31h, 46h): 31(=1Fh)
WW: weekdays
'0'-'0'(30h, 30h): Sunday
'0'-'1'(30h, 31h): Monday
'0'-'2'(30h, 32h): Tuesday
'0'-'3'(30h, 33h): Wednesday
'0'-'4'(30h, 34h): Thursday
'0'-'5'(30h, 35h): Friday
'0'-'6'(30h, 36h): Saturday
HH: Hours
'0'-'0'(30h, 30h): 0
|
'1'-'7'(31h, 37h): 23 (=17h)
MN: Minutes
'0'-'0'(30h, 30h): 0
|
'3'-'B' (33h, 42h): 59 (=3Bh)
DS: Daylight saving (Summer time)
'0'-'0'(30h, 30h): NO
'0'-'1'(30h, 31h): YES
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
Message
STX-'C'-'3'-'1'-'2'-ST-YY-MM-DD-WW-HH-MN
-DS-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'1'-'6'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'6'(31h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'2' (43h, 33h, 31h, 32h): Date & Time write reply command
(22/50)
ST: Date & Time Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
'YY'-'MM'-'DD'-'WW'-'HH'-'MN'-'DS': Date & Time data
YY: Year (offset 2000)
'0'-'0'(30h, 30h): 2000
|
'6'-'3'(36h, 33h): 2099 (99 = 63h)
MM: Month
'0'-'1'(30h, 31h): January
|
'0'-'C'(30h, 43h): December
DD: Day
'0'-'1'(30h, 31h): 1
|
'1'-'E'(31h, 45h): 30(=1Eh)
'1'-'F'(31h, 46h): 31(=1Fh)
WW: weekdays
'0'-'0'(30h, 30h): Sunday
'0'-'1'(30h, 31h): Monday
'0'-'2'(30h, 32h): Tuesday
'0'-'3'(30h, 33h): Wednesday
'0'-'4'(30h, 34h): Thursday
'0'-'5'(30h, 35h): Friday
'0'-'6'(30h, 36h): Saturday
HH: Hours
'0'-'0'(30h, 30h): 0
|
'1'-'7'(31h, 37h): 23 (=17h)
MN: Minutes
'0'-'0'(30h, 30h): 0
|
'3'-'B' (33h, 42h): 59 (=3Bh)
DS: Daylight saving (Summer time)
'0'-'0'(30h, 30h): NO
'0'-'1'(30h, 31h): YES
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
10. Schedule read and write
10.1 Schedule Read
This command is used in order to read the setting of the Schedule.
1) The controller requests the monitor to read Schedule.
Header
Message
STX-'C'-'2'-'2'-'1'-PG-ETX
Checkcode
BCC
Delimiter
CR
SOH-'0'-MonitorID-'0'-'A'-'0'-'8'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
(23/50)
'0'-'8'(30h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'2'-'1' (43h, 32h, 32h, 31h): Schedule read request command.
PG: Program No.
The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Schedule to the controller.
Header
Message
Checkcode
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'2'-'6'
STX-'C'-'3'-'2'-'1'-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-P MODE-
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'2'-'6'(32h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'2'-'1' (43h, 33h, 32h, 31h): Schedule read reply command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE-
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn't set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h,30h): No mean (works on last memory)
(24/50)
'0'-'1'(30h,31h): VGA
'0'-'2'(30h,32h): RGB/HV
'0'-'3'(30h,33h): DVI
'0'-'5'(30h,35h): Video1
'0'-'6'(30h,36h): Video2
'0'-'7'(30h,37h): S-Video
'0'-'A'(30h,41h): TV
'0'-'C'(30h,43h): DVD/HD1
'0'-'D'(30h,44h): Option
'0'-'E'(30h,45h): DVD/HD2
'0'-'F'(30h,46h): Display Port
'1'-'1'(31h,31h): HDMI
WD: Week setting
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
P MODE: Picture mode
'0'-'0'(30h,30h): No mean (works on last memory)
'0'-'1'(30h,31h): sRGB
'0'-'3'(30h,33h): Hi-Bright
'0'-'4'(30h,34h): Standard
'0'-'5'(30h,34h): Cinema
'0'-'6'(30h,36h): ISF-Day
'0'-'7'(30h,37h): ISF-Night
'0'-'B'(30h,42h): Ambient-1
'0'-'C'(30h,43h): Ambient-2
EXT1: Extension1
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT2: Extension 2
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT3: Extension 3
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT4: Extension 4
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT5: Extension 5
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT6: Extension 6
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT7: Extension 7
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
ETX (03h): End of Message
(25/50)
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
***Following command also can be used for to keep backward compatibility, in order to
read the setting of the Schedule.
1) The controller requests the monitor to read Schedule.
Header
Message
STX-'C'-'2'-'1'-'3'-PG-ETX
Checkcode
BCC
Delimiter
CR
SOH-'0'-MonitorID-'0'-'A'-'0'-'8'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'3' (43h, 32h, 31h, 33h): Schedule read request command.
PG: Program No.
The data must be ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies Schedule to the controller.
Header
Message
Checkcode
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'1'-'6'
STX-'C'-'3'-'1'-'3'-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'6'(31h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'3' (43h, 33h, 31h, 33h): Schedule read reply command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
(26/50)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn't set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h, 30h): DVI
'0'-'1'(30h, 31h): VGA
'0'-'2'(30h, 32h): RGB/HV
'0'-'3'(30h, 33h): DVD/HD1
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): S-VIDEO
'0'-'7'(30h,30h): No mean (Works on last memory)
WD: Week setting
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
10.2 Schedule Write
(27/50)
This command is used in order to write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'2'-'6'
STX-'C'-'2'-'2'-'2'-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-P MODE-
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'2'-'6'(32h, 36h): Message length.
Message
STX (02h): Start of Message
'C'-'2'-'2'-'2' (43h, 32h, 32h, 32h): Schedule writes command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h,30h): No mean (works on last memory)
'0'-'1'(30h,31h): VGA
'0'-'2'(30h,32h): RGB/HV
'0'-'3'(30h,33h): DVI
'0'-'4'(30h,34h): HDMI (Set only)
'0'-'5'(30h,35h): Video1
'0'-'6'(30h,36h): Video2
'0'-'7'(30h,37h): S-Video
'0'-'A'(30h,41h): TV
'0'-'C'(30h,43h): DVD/HD1
'0'-'D'(30h,44h): Option
'0'-'E'(30h,45h): DVD/HD2
'0'-'F'(30h,46h): Display Port
'1'-'1'(31h,31h): HDMI
* Please select active input on your system (setting).
* If you select inactive input here, the input change execution will be ignored.
(28/50)
WD: Week setting
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
* When bit 0 and bit 1 are '1', it behaves as Everyday.
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
P MODE: Picture mode
'0'-'0'(30h,30h): No mean (Works on last memory)
'0'-'1'(30h,31h): sRGB
'0'-'3'(30h,33h): Hi-Bright
'0'-'4'(30h,34h): Standard
'0'-'5'(30h,34h): Cinema
'0'-'6'(30h,36h): ISF-Day
'0'-'7'(30h,37h): ISF-Night
'0'-'B'(30h,42h): Ambient-1
'0'-'C'(30h,43h): Ambient-2
* Please select active picture mode on your system (setting).
* If you select inactive picture mode here, the input change execution will be ignored.
EXT1: Extension1
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT2: Extension 2
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT3: Extension 3
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT4: Extension 4
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT5: Extension 5
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT6: Extension 6
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT7: Extension 7
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
(29/50)
2) The monitor replies a data for confirmation.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'2'-'8'
STX-'C'-'3'-'2'-'2'-ST-PG-ONHOUR-ONMIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-P MODE-
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'2'-'8'(32h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'2'-'2' (43h, 33h, 32h, 32h): Schedule writes reply command
ST: Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE
EXT1-EXT2-EXT3-EXT4-EXT5-EXT6-EXT7: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h,30h): No mean (works on last memory)
'0'-'1'(30h,31h): VGA
'0'-'2'(30h,32h): RGB/HV
'0'-'3'(30h,33h): DVI
'0'-'5'(30h,35h): Video1
'0'-'6'(30h,36h): Video2
'0'-'7'(30h,37h): S-Video
'0'-'A'(30h,41h): TV
'0'-'C'(30h,43h): DVD/HD1
'0'-'D'(30h,44h): Option
'0'-'E'(30h,45h): DVD/HD2
'0'-'F'(30h,46h): Display Port
'1'-'1'(31h,31h): HDMI
WD: Week setting
bit 0: Monday
(30/50)
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
* When bit 0 and bit 1 are '1', it behaves as Everyday.
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
P MODE: Picture mode
'0'-'0'(30h,30h): No mean (works on last memory)
'0'-'1'(30h,31h): sRGB
'0'-'3'(30h,33h): Hi-Bright
'0'-'4'(30h,34h): Standard
'0'-'5'(30h,34h): Cinema
'0'-'6'(30h,36h): ISF-Day
'0'-'7'(30h,37h): ISF-Night
'0'-'B'(30h,42h): Ambient-1
'0'-'C'(30h,43h): Ambient-2
EXT1: Extension1
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT2: Extension 2
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT3: Extension 3
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT4: Extension 4
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT5: Extension 5
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT6: Extension 6
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
EXT7: Extension 7
'0'-'0'(30h,30h): (On this monitor, it is always ‘00’)
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
3) The controller requests the monitor to write Enable/Disable Schedule.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-MonitorID-'0'-'A'-'0'-'A'
STX-'C'-'2'-'1'-'5'-PG-EN-ETX
Header
(31/50)
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h, 41h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'5' (43h, 32h, 31h, 35h): Enable/Disable Schedule writes command
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
4) The monitor replies a data for confirmation.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'0'-'C'
STX-'C'-'3'-'1'-'5'-ST-PG-EN-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'C' (30h, 43h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'5' (43h, 33h, 31h, 35h): Enable/Disable Schedule writes reply command
ST: Enable/Disable Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
(32/50)
***Following command also can be used for to keep backward compatibility, in order to
write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'1'-'6'
STX-'C'-'2'-'1'-'4'-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'6'(31h, 36h): Message length.
Message
STX (02h): Start of Message
'C'-'2'-'1'-'4' (43h, 32h, 31h, 34h): Schedule writes command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h, 30h): DVI
'0'-'1'(30h, 31h): VGA
'0'-'2'(30h, 32h): RGB/HV
'0'-'3'(30h, 33h): DVD/HD1
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): S-VIDEO
'0'-'7'(30h, 37h): (Works on last memory)
* Please select active input on your system (setting).
* If you select inactive input here, the input change execution will be ignored.
WD: Week setting
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
(33/50)
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
* When bit 0 and bit 1 are '1', it behaves as Everyday.
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'1'-'8'
STX-'C'-'3'-'1'-'4'-ST-PG-ONHOUR-ONMIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'1'-'8'(31h, 38h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'4' (43h, 33h, 31h, 34h): Schedule writes reply command
ST: Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.
ON_MIN: Turn on time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59
'3'-'C'(33h, 43h): On timer isn’t set.
OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
(34/50)
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h, 30h): DVI
'0'-'1'(30h, 31h): VGA
'0'-'2'(30h, 32h): RGB/HV
'0'-'3'(30h, 33h): DVD/HD1
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): S-VIDEO
'0'-'7'(30h,30h): No mean (Works on last memory)
WD: Week setting
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
* When bit 0 and bit 1 are '1', it behaves as Everyday.
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
3) The controller requests the monitor to write Enable/Disable Schedule.
Header
Message
Check code
Delimiter
CR
SOH-'0'-MonitorID-'0'-'A'-'0'-'A'
STX-'C'-'2'-'1'-'5'-PG-EN-ETX
BCC
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'A'(30h, 41h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'5' (43h, 32h, 31h, 35h): Enable/Disable Schedule writes command
(35/50)
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
4) The monitor replies a data for confirmation.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'0'-'C'
STX-'C'-'3'-'1'-'5'-ST-PG-EN-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'C' (30h, 43h): Message length
Message
STX (02h): Start of Message
'C'-'3'-'1'-'5' (43h, 33h, 31h, 35h): Enable/Disable Schedule writes reply command
ST: Enable/Disable Schedule Status command
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
PG-EN: Enable/Disable Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
11. Self diagnosis
11.1 Self-diagnosis status read
This command is used in order to read the Self-diagnosis status.
1) The controller requests the monitor to read Self-diagnosis status.
Header
Message
STX-'B'-'1'-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'0'-'4'
Header
(36/50)
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get status.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'4'(30h, 34h): Message length
Message
STX (02h): Start of Message
'B'-'1' (42h, 31h): Self-diagnosis command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a result of the self-diagnosis.
Header
Message
STX-'A'-'1'-
ST(0)-ST(1) --------ST(n)-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-N-N
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximumdata length that can be written to the monitorat a time is 32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (34h and 30h).
Message
STX (02h): Start of Message
'A'-'1' (41h, 31h): Application Test Report reply command
ST: Result of self-tests
'0'-'0'(30h, 30h):00: Normal
'7'-'0'(37h, 30h):70: Standby-power +3.3V abnormality
'7'-'1'(37h, 31h):71: Standby-power +5V abnormality
'7'-'2'(37h, 32h):72: Panel-power +12V abnormality
'7'-'3'(37h, 33h):73: Main-power +2.5V abnormality
'7'-'4'(37h, 34h):74: Main-power +1.8V abnormality
'7'-'5'(37h, 35h):75: Main-power +5V abnormality
'7'-'6'(37h, 36h):76: Sub-power +3.3V abnormality
'7'-'7'(37h, 37h):77: Main-power +3.3V abnormality
'8'-'0'(38h, 30h):80: Cooling fan-1 abnormality
'8'-'1'(38h, 31h):81: Cooling fan-2 abnormality
('8'-'2'(38h, 32h):82: Cooling fan-3 abnormality)
'9'-'0'(39h, 30h):90: Inverter abnormality
'A'-'0'(41h, 30h):A0: Temperature abnormality – shutdown
'A'-'1'(41h, 31h):A1: Temperature abnormality – half brightness
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
(37/50)
12. Serial No. & Model Name Read
12.1 Serial No. Read
This command is used in order to read a serial number.
1) The controller requests the monitor to read a serial number.
Header
Message
STX-'C'-'2'-'1'-'6'-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-Monitor ID-'0'-'A'-'0'-'6'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get serial number.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'6' (43h, 32h, 31h, 36h): Serial No. command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the serial No. data to the controller.
Header
Message
STX-'C'-'3'-'1'-'6'-
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-N-N
Data(0)-Data(1)---Data(n)-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximum data length that can be returned from the monitor at a time is
32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'3'-'1'-'6' (41h, 33h, 31h, 36h): Serial No. reply command
Data(0)-Data(1)----Data(n):Serial Number
These data are encoded to ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
12.2 Model Name Read
This command is used in order to read the Model Name.
1) The controller requests the monitor to read Model Name.
Header
Message
Check code
Delimiter
(38/50)
SOH-'0'-MonitorID-'0'-'A'-'0'-'6'
STX-'C'-'2'-'1'-'7'-ETX
BCC
CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID which you want to get Model Name.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'6'(30h, 36h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'7' (43h, 32h, 31h, 37h): Model Name command
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the model name data to the controller.
Header
Message
STX-'C'-'3'-'1'-'7'-Data(0) -Data(1)—---
-Data(n)-ETX
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-N-N
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
N-N: Message length
Note.) The maximum data length that can be returned from the monitor at a time is
32bytes.
Ex.) The byte data 20h is encoded as ASCII characters '2' and '0' (32h and 30h).
Message
STX (02h): Start of Message
'C'-'3'-'1'-'7' (43h, 33h, 31h, 37h): Model Name reply Command
Data(0) -Data(1)----Data(n):Model name
These data are encoded to ASCII characters strings.
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
13. Security Lock
13.1 Security Lock Control
This command sets the condition of security lock function to "LOCK" or "UNLOCK".
If security pass codes 1st to 4th are matched with monitor resisted pass codes, then this
command is executed, and reply no error status and a new condition.
If codes aren't matched with them then setting isn't changed, and reply error status and
a current condition.
If the monitor receives this command while waiting for Pass codes inputs, then it only
checks Pass cords (and releases image muting if Pass codes are OK) and doesn't apply "EN"
parameter.
(39/50)
1) The controller requests the monitor to set the condition of security lock.
Header Message
Check
code
BCC
Delimiter
CR
SOH-'0'-MonitorID-'0'-'A'-'1'-'0' STX-'C'-'2'-'1'-'D'-EN-P1-P2-P3-P4-ETX
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'0'(31h, 30h): Message length
Message
STX (02h): Start of Message
'C'-'2'-'1'-'D' (43h, 32h, 31h, 44h): Security Lock Control command
EN-P1-P2-P3-P4: Lock condition control data
EN: Enable /Disable
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
P1: Security Pass code 1st
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
P2: Security Pass code 2nd
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
P3: Security Pass code 3rd
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
P4: Security Pass code 4th
'0'-'0'(30h, 30h): "0"
|
'0'-'9'(30h, 39h): "9"
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies the result to the controller.
Header
Message
Check code
BCC
Delimiter
CR
SOH-'0'-'0'-Monitor ID-'B'-'0'-'A'
STX-'C'-'3'-'1'-'D'-ST-EN-ETX
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length
Message
STX (02h): Start of Message
(40/50)
'C'-'3'-'1'-'D' (43h, 33h, 31h, 44h): Security Lock Control reply command
ST-EN: Lock condition result data
ST: Status
'0'-'0'(30h, 30h): No error
'0'-'1'(30h, 31h): Error
EN: Enable /Disable (Current condition)
'0'-'0'(30h, 30h): Disable
'0'-'1'(30h, 31h): Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
(41/50)
Appendix
A. Operation Code (OP code) Table
Item
OP
OP code
10h
Parameter
Remarks
code
page
00h
Brightness
Contrast
0: dark
|
100(64h): bright
0: low
00h
00h
00h
00h
02h
00h
12h
|
100(64h): high
0: dull
|
82(52h): sharp
0: dark
|
63(3Fh): bright
0: purplish
|
63(3Fh): greenish
0: pale
|
Sharpness
Black Level
Tint
8Ch
92h
90h
Color
1Fh
63(3Fh): deep
0:2600K
Color Temperature
54h
100K/step
|
74(4Ah):10000K
X461HB’s
minimum is
4(04h):3000K
Color control
00h
Red: 9Bh
0:
Yellow: 9Ch
Green: 9Dh
Cyan: 9Eh
Blue: 9Fh
Magenta: A0h
Saturation:
8Ah
|
50(32h):(center)
|
100(64h):
0: pale
|
10(0Ah): deep
Gamma Selection
02h
68h
Gamma
Table Selection
1: Native Gamma
4: Gamma=2.2
8: Gamma=2.4
7: S Gamma
5: DICOM SIM.
6: Programmable
0: None
1: Off
2: Low
3: Middle
4: High
0: Off
Movie
Settings
Adaptive
Contrast
02h
02h
8Dh
20h
Noise
Reduction
|
16(10h) : High
Film Mode
02h
02h
23h
1Ah
1: Off
2: Auto
1: sRGB
Picture mode
sRGB:
3: Hi-Bright
4: Standard
5: Cinema
6: ISF-Day
7: ISF-Night
11: Ambient-1
12: Ambient-2
PCmodeonly
Cinema:
A/V mode only
ISF-Day:
ISF-Night:
Each needs an
adjustmentby
ISF.
(42/50)
Item
OP
OP code
33h
Parameter
Remarks
code
page
10h
Ambient
Ambient
0: dark
Brightness
Low
|
100(64h): bright
Ambient
Brightness
High
Get Current
Illuminance
10h
02h
02h
02h
34h
0: dark
|
100(64h): bright
0:
B4h
Read only
Read only
Momentary
|
Max.
0:
|
255(FFh)
0: None
Bright
Sensor Read
B5h
Menu tree reset
(Picture)
CBh
2: Reset
Picture category
Auto Setup
Auto Adjust
H Position
00h
00h
1Eh
20h
1: Execute
N/A
0: Left side
|
Momentary
Depends on a
display
Max.: Right side
0: Bottom side
|
Max.: Top side
0:
timing
Depends on a
display
V Position
Clock
00h
00h
00h
02h
02h
02h
30h
0Eh
3Eh
50h
51h
DAh
timing
|
Max. :
0:
|
Max. :
0: Low
|
Max. : High
0: Low
|
Max.: High
1: Auto
Clock Phase
H Resolution
V Resolution
Input Resolution
2: 1024x768
3: 1280x768
4: 1360x768
5: 1366x768
6: 1400x1050
7: 1680x1050
3:16:9-ZOOM
4:14:9-ZOOM
5:Dynamic
1:Off (Real)
2:Custom
Zoom Mode
Base Zoom
02h
CEh
Zoom
02h
02h
02h
02h
6Fh
6Ch
6Dh
CCh
1:100
2:101
|
%
%
201:300
%
%
%
Zoom
H-Expansion
1:100
2:101
|
%
%
201:300
Zoom
V-Expansion
1:100
2:101
|
201:300
0: Left side
%
%
Zoom
H-Position
|
Max.: Right side
(43/50)
Item
OP
OP code
CDh
Parameter
Remarks
code
page
02h
Zoom
V-Position
0: Down side
|
Max.: Up side
1: Normal
2: Full
3: Wide
4: Zoom
Aspect
02h
70h
Wide:
A/V mode only
(exc.X431BT)
Notavailable
(X431BT)
5: Trim
Trim:
X431BT only
Menu tree reset
(Adjust)
02h
00h
CBh
93h
0: None
Momentary
3: Reset
Adjust category
O: Left
Balance
Treble
Bass
Notavailable
on X461UN.
|
50:(Center)
|
100: Right
O: Min.
|
50:(Center)
|
100: Max.
0: Min.
|
00h
00h
8Fh
91h
Notavailable
on X461UN.
Notavailable
on X461UN.
50:(Center)
|
100: Max.
PIP Audio
Line out
SURROUND
N/A
N/A
1: Off
2: Low (or On)
3: High (or On)
1: Audio 1(PC)
2: Audio 2
3: Audio 3
4: HDMI
02h
02h
34h
2Eh
Notavailable
on X461UN.
Audio Input
6: TV/Option
7: Display Port
0: None
4: Reset
Audio category
0: Off
Menu tree reset
(Audio)
02h
02h
CBh
2Bh
Momentary
Off Timer
1 hour/step
1: 1 hour
|
24: 24 hours
0: No Mean
1: No.1 Enable
|
7: No.7 Enable
0: No Mean
1: No.1 Disable
|
7: No.7 Disable
0: None
5: Reset
Schedule category
N/A
Enable Schedule
02h
02h
02h
E5h
E6h
CBh
Disable Schedule
Menu tree reset
(Schedule)
Momentary
Keep PIP Mode
(44/50)
Item
OP
OP code
72h
Parameter
Remarks
code
page
02h
PIP Mode
1: Off
POP:
2: PIP
3: POP
(4: Still)
5: Side by side
(aspect)
Side by side
(aspect):
Notavailable
on X431BT
6: Side by side
(Full)
7: POP aspect Main
8: POP aspect Sub
POP
aspectMain:
POP
aspect Sub:
X431BT only
PIP Size
02h
02h
02h
71h
74h
75h
1: Small
2: Middle
3: Large
0: left
|
PIP H Position
PIP V Position
100(64h): right
0: top
|
100(64h): bottom
Aspect
N/A
Text Ticker
Mode
10h
08h
0: None
1: Off
2: Horizontal
3: Vertical
0: Top/Left
|
100: Bottom/Right
0-1: Do not set.
2: Narrow(2/24)
|
Position
Size
10h
10h
09h
0Ah
8: Wide(8/24)
Blend
10h
10h
10h
02h
0Bh
0Ch
0Dh
73h
1: 10%
|
10: 100%
0: None
1: Auto
2: Off
0: None
1: On
Detect
Fade In
2: Off
0: No mean
1: VGA
PIP Input(Sub input)
This
operationhas
limitationof
selection.
Please refer
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: Video1
6: Video2
7: S-Video
10: TV
to
the
monitor
instruction
manual.
12: DVD/HD1
13: Option
14: DVD/HD2
15: Display Port
17: HDMI
Menu tree reset
(PIP)
02h
00h
CBh
68h
0: None
6: Reset
Momentary
PIP category
1: English
2: German
3: French
4: Spanish
5: Japanese
6: Italian
7: Swedish
9: Russian
Language
OSD Language
(45/50)
Item
OP
OP code
FCh
Parameter
Remarks
code
page
00h
OSD Turn Off
0-1: Do not set.
2: 10s
5sec/step
3: 15s
|
48: 240s
OSD
Position
H
02h
02h
02h
38h
39h
3Dh
0: Left
|
MAX.: Right
0: Down
Position
V
Position
|
MAX.: Up
Information OSD
OSD Transparency
0:Disable
information OSD
3-10:
OSD timer [seconds]
0: None
1: Off(Opaque)
2: TYPE1
3: TYPE2
0: None
7: Reset
02h
02h
B8h
CBh
Menu tree reset
(OSD)
Momentary
OSD category
Monitor ID
IR Control
02h
02h
3Eh
3Fh
1-100:ID
1: Normal
2: Primary
3: Secondary
4: Lock (Off)
1
|
10
1
|
Tile
Matrix
H monitor
V monitor
Position
02h
02h
02h
D0h
D1h
D2h
Number
ofH-division
Number
ofV-division
10
1: Upper left
|
MAX.: Lower right
1: Disable (Off)
2: Enable (On)
1: Disable (Off)
and display frame
2: Enable (On)
3: Disable (Off)
and erase frame
(Set only)
0: Off (0sec)
Tile comp
Mode
02h
02h
D5h
D3h
Power On Delay
02h
D8h
│
50:50sec
0: None
1: On
Power Indicator
External control
02h
10h
BEh
3Eh
2: Off
0: No mean
1: RS-232C
2: LAN
Setting copy
N/A
Menu tree reset
(Multi Display)
02h
CBh
0: None
8: Reset
Multi Display
category
0: Off
Momentary
Power Save
00h
02h
E1h
9Ah
1: On
Standby Mode
0: None
1: Standby
2: ECO Standby
(46/50)
Item
OP
OP code
7Dh
Parameter
Remarks
code
page
02h
Fan Control
0: None
Offset
1: Auto(No offset)
2: Forced ON
affects to a
selected
sensor.
3: Auto(offset -2)
4: Auto(offset -4)
5: Auto(offset -6)
6: Auto(offset -8)
7: Auto(offset -10)
Fan Speed
10h
02h
02h
02h
02h
3Fh
DBh
DCh
DDh
DFh
0: None
1: High
2: Low
Screen Saver
Gamma
1: normal
2:screen saving
gamma
1:normal
2:decrease
brightness
0: 0s(Off)
|
90: 900s
0: Black
|
100: White
0: Off
Brightness
Motion
10s/step
Side Border Color
Auto Brightness
02h
02h
2Dh
CBh
1: On
0: None
Menu tree reset
Momentary
(Display Protection)
9: Reset
Display Protection
category
0: First detect
1: Last detect
2: None
Input Detect
02h
40h
3: VIDEO detect
4: Custom detect
0: No mean
1: VGA
Custom
Detect
Priority1
10h
2Eh
2: RGB/HV
3: DVI
Priority2
Priority3
Priority4
Priority5
10h
10h
10h
10h
2Fh
30h
31h
32h
4: HDMI (Set only)
5: Video1
6: Video2
7: S-Video
10: TV
12: DVD/HD1
13: Option
14: DVD/HD2
15: Display Port
17: HDMI
N/A
Input change
Long Cable
Manual
Equalize
Pole
10h
10h
10h
10h
10h
3Dh
36h
37h
38h
39h
0: No mean
1: Off
2: On
0:
|
255(FFh):
0:
|
255(FFh):
0:
|
255(FFh):
0:
Peak
Gain
Offset
|
255(FFh):
(47/50)
Item
OP
OP code
Parameter
Remarks
code
page
02h
SYNC
Terminate
E1h
CFh
7Eh
1: Hi(2.2kohm)
2: Lo(75ohm)
1: DVI-PC
2: DVI-HD
0: No operate
1: RGB
DVI Mode
BNC Mode
02h
10h
2: Component
3: Video
SCART Mode
02h
10h
9Eh
40h
0: Off
1: On
0: None
HDMI Signal
1: Expand
2: Raw
Scan Conversion
Color System
02h
02h
25h
21h
1: Off(INTERLACE)
2: Enable
(IP ON/PROGRESSIVE)
1: NTSC
2: PAL
3: SECAM
4: Auto
5: 4.43NTSC
6: PAL-60
Scan Mode
02h
02h
E3h
CBh
1: Under Scan
2: Over Scan
0: None
Menu tree reset
Momentary
Momentary
(Advanced Option)
10: Reset Advanced
option category
0: None
1: Factory Reset
0: No mean
1: VGA
Menu tree reset
(Factory reset)
Input
02h
00h
CBh
60h
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: Video1
6: Video2
7: S-Video
10: TV
12: DVD/HD1
13: Option
14: DVD/HD2
15: Display Port
17: HDMI
Audio Input
02h
00h
2Eh
62h
1: Audio 1(PC)
2: Audio 2
3: Audio 3
4: HDMI
6: TV/Option
7: Display Port
0: whisper
|
Volume UP/Down
100: loud
Mute
MTS
00h
02h
8Dh
2Ch
0,2: UNMUTE
1: MUTE
0: None
This
1: Main
2: Sub
3: Main + Sub
operation
requires
supported
option
TV
tuner.
Sound
02h
34h
1: Off
2: Low (or On)
3: High (or On)
Notavailable
on X461UN.
(48/50)
Item
OP
OP code
1Ah
Parameter
Remarks
code
page
02h
Picture Mode
1: sRGB
sRGB:
3: Hi-Bright
4: Standard
5: Cinema
PCmodeonly
Cinema:
A/V mode only
6: ISF-Day
7: ISF-Night
11: Ambient-1
12: Ambient-2
ISF-Day:
ISF-Night:
Each needs an
adjustmentby
ISF.
Aspect
02h
02h
70h
72h
1: Normal
2: Full
3: Wide
4: Zoom
1: Off
Wide:
A/V mode only
PIP ON/OFF
Still ON/OFF
2: PIP
3: POP
4: Still
5:Side by side
(aspect)
6: Side by side
(Full)
PIP Input
02h
73h
0: No mean
1: VGA
2: RGB/HV
3: DVI
4: HDMI (Set only)
5: Video1
6: Video2
7: S-Video
10: TV
This
operationhas
limitationof
selection.
Please refer
to
monitor
the
instruction
manual.
12: DVD/HD1
13: Option
14: DVD/HD2
15: Display Port
17: HDMI
Still Capture
02h
02h
76h
EAh
0: Off
Momentary
1: Capture
0: No Action
1: Off
Signal Information
(No indication)
2: On
(Indication
1: Execute
0: No Action
1: Up
)
Auto Setup
TV-Channel UP/DOWN
00h
00h
1Eh
8Bh
Momentary
This
operation
requires
supported
2: Down
option
tuner.
TV
Select Temperature sensor
Readout a temperature
02h
02h
10h
10h
78h
79h
10h
11h
1: Sensor #1
2: Sensor #2
3: Sensor #3
Returned value is
2's complement.
Refertosection6.2
0:
|
999:
Read only
Read only
Read only
Readout carbon footprint
(g)
Readout carbon footprint
(kg)
0:
|
65535:
(49/50)
All data are subject to change without notice.
(Revised at Mar.25/2010)
Copyright 2004-2009 NEC Display Solutions, Ltd. All Right Reserved
This document provides the technical information for users. NEC Display Solutions, Ltd. reserves the right to change or modify the information contained
herein without notice. NEC Display Solutions, Ltd. makes no warranty for the use of its products and bears no responsibility for any errors or omissions which
may appear in this document.
(50/50)
|