AccuSync LCD72XM
AccuSync LCD92XM
User’s Manual
For the Customer to use in U.S.A. or Canada
Canadian Department of Communications Compliance Statement
DOC: This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouiller du Canada.
C-UL: Bears the C-UL Mark and is in compliance with Canadian Safety Regulations according to CSA C22.2 No. 60950-1.
Ce produit porte la marque ‘C-UL’ et se conforme aux règlements de sûrele Canadiens selon CAN/CSA C22.2 No. 60950-1.
FCC Information
1.
Use the attached specified cables with the AccuSync LCD72XM/AccuSync LCD92XM colour monitor so as not to
interfere with radio and television reception.
(1)
The power supply cord you use must have been approved by and comply with the safety standards of U.S.A.,
and meet the following condition.
Power supply cord
Length
Non shield type, 3-conductor
1.8 m
Plug shape
U.S.A
(2)
Please use the supplied shielded video signal cable. Use of other cables and adapters may cause interference
with radio and television reception.
2.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult your dealer or an experienced radio/TV technician for help.
If necessary, the user should contact the dealer or an experienced radio/television technician for additional
suggestions. The user may find the following booklet, prepared by the Federal Communications Commission, helpful:
“How to Identify and Resolve Radio-TV Interference Problems.” This booklet is available from the U.S. Government
Printing Office, Washington, D.C., 20402, Stock No. 004-000-00345-4.
Declaration of Conformity
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions. (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
U.S. Responsible Party: NEC Display Solutions of America, Inc.
Address:
500 Park Blvd, Suite 1100
Itasca, Illinois 60143
(630) 467-3000
Tel. No.:
Type of Product:
Display Monitor
Equipment Classification: Class B Peripheral
Model: AccuSync LCD72XM (L174F1)/AccuSync LCD92XM (L194F2)
We hereby declare that the equipment specified above conforms
to the technical standards as specified in the FCC Rules.
English-2
Contents
Your new NEC AccuSync LCD monitor box* should contain the following:
•
•
•
•
•
•
•
•
AccuSync LCD monitor with tilt base
Audio Cable
•
DVI-D Cable (LCD92XM only)
Power Cord
Video Signal Cable
User’s Manual
CD-ROM
Base Stand
Cable Holder
DVI-D Cable
(LCD92XM only)
Cable Holder
CD-ROM
User’s Manual
Audio Cable
Power Cord
Video Signal Cable
Base Stand
AccuSync LCD monitor
(base stand not connected)
*
Remember to save your original box and packing material to transport or ship the monitor.
Quick Start
To attach the Base to the LCD Stand:
1. Insert the front of the LCD stand into the holes in the front of the Base (Figure S.1).
2. Next, position the locking tabs on the back side of the LCD stand with the holes on the Base. Lower the Stand in place until
locking tabs are secure (Figure S.1).
To attach the Cable Holder:
1. Insert the tabs of Cable Holder into the hole of Stand neck (Figure S.1).
NOTE:
Please confirm that the tabs are completely secure.
Stand
Cable Holder
Locking Tabs
Base
Macintosh Cable
Adapter (not included)
Figure S.1
Figure A.1
Figure A.2
To attach the AccuSync LCD monitor to your system, follow these instructions:
1. Turn off the power to your computer.
2. For the PC or MAC with DVI digital output: Connect the DVI-D signal cable (included with LCD92XM only) to the
connector of the display card in your system (Figure B.1). Tighten all screws.
For the PC with Analog output: Connect the 15-pin mini D-SUB signal cable to the connector of the display card in your
system (Figure A.1). Tighten all screws.
For the Mac: Connect the MultiSync Macintosh cable adapter (not included) to the computer. Attach the 15-pin mini
D-SUB signal cable to the MultiSync Macintosh cable adapter (Figure A.2). Tighten all screws.
NOTE:
Some Macintosh systems do not require a Macintosh cable adapter.
English-3
3. Connect the 15-pin mini D-SUB of the video signal cable and Audio Cable to the appropriate connector on the back of the
monitor (Figure B.1). Connect the Headphone (not included) to the appropriate connector at the front of the monitor
(Figure C.1).
4. Connect one end of the power cord to the monitor and the other end to the power outlet. Place the Video Signal Cable and
power cord to the Cable holder (Figure B.1).
NOTE:
NOTE:
Adjust position of cable that place under the Cable holder to avoid damage for cable or monitor.
Please refer to Caution section of this manual for proper selection of power cord.
5. Turn on the monitor with the front power button and the computer (Figure C.1).
AUDIO INPUT
DVI-D (Input2)
D-Sub (Input1)
Power Button
Cable holder
Headphone
Connect to
Computer audio output
Figure B.1
Figure C.1
6. No-touch Auto Adjust automatically adjusts the monitor to optimal settings upon initial setup for most timings.
For further adjustments, use the following OSM controls:
• Auto Adjust Contrast
• Auto Adjust
Refer to the Controls section of this User’s Manual for a full description of these OSM controls.
NOTE:
If you have any problem, please refer to the Troubleshooting section of this
User’s Manual.
Tilt
Grasp both sides of the monitor screen with your hands and adjust the tilt as desired
(Figure TS.1).
Remove Monitor Stand for Mounting
To prepare the monitor for alternative mounting purposes:
Figure TS.1
1. Disconnect all cables.
2. Place monitor face down on a non-abrasive surface (Figure R.1).
3. Remove the 4 screws connecting the monitor to the stand and remove the stand as indicated (Figure R.2).
The monitor is now ready for mounting in an alternative manner.
4. Connect the AC cord and signal cable to the back of the monitor (Figure R.3).
5. Reverse this process to re-attach stand.
NOTE:
NOTE:
Use only VESA-compatible alternative mounting method.
Handle with care when removing monitor stand.
English-4
Non-abrasive surface
Figure R.1
Figure R.2
Figure R.3
Removing the Base
NOTE:
Always remove the Base when shipping the LCD.
1. Place monitor face down on a non-abrasive surface (Figure R.1).
2. While using your thumbs, press the bottom tabs upward to unlock.
3. Press the top tabs down to unlock and pull off the stand.
Connecting a Flexible Arm
This LCD monitor is designed for use with a flexible arm.
Please use the attached screws (4pcs) as shown in the picture when installing. To meet the safety requirements, the monitor
must be mounted to an arm which guaranties the necessary stability under consideration of the weight of the monitor.
The LCD monitor shall only be used with an approved arm (e.g. GS mark).
Replace screws
Thickness of Bracket
(Arm) 2.0 ~ 3.2 mm
Tighten all screws
100 mm*
100 mm*
* (LCD72XM/LCD92XM)
Specifications
4-SCREWS (M4)
(MAX depth: 8.5 mm)
If use other
screw, check
depth of hole.
Weight of LCD assembly: 4.3 kg - LCD72XM (MAX)
5.5 kg - LCD92XM (MAX)
English-5
Controls
OSM (On-Screen Manager) control buttons on the front of the monitor
function as follows:
1. Basic function at pressing each key
SELECT
Showing OSM.
Go to Adjustment stage.
1<->2 / RESET
–
+
Button
At No OSD
showing
Shortcut to Bright adjust
window.
Shortcut to Volume adjust
window.
Input signal select.
At OSD showing
(Icon selection stage)
Cursor goes to left.
Cursor goes to right.
At OSD showing Go to Icon selection stage.
(Adjustment stage)
Adjust value decrease or
Adjust value increase or
Reset operation.
Mute off/on switch on Volume
adjustment window.
Cursor for adjust goes to left. Cursor for adjust goes to
right.
2. OSM structure
Main Menu (Icon Select, Analog Input)
Main Menu (Adjust)
Press
“SELECT”
key
Press
“SELECT”
key
Press “SELECT” key
Adjust by using
“–” or “+”
Example Tool:
Press “SELECT” key
Press
“SELECT” key
Press
“–” or “+”
Press
“–” or “+”
Press
“SELECT” key
Sub Menu (Icon Select)
Adjust by using
“–” or “+”
Sub Menu (Adjust)
English-6
AUDIO
Control the sound volume of speakers and headphone.
To mute the speaker sound, press the 1<->2/RESET key.
BRIGHTNESS
Adjusts the overall image and background screen brightness.
CONTRAST
Adjusts the image brightness in relation to the background.
AUTO CONTRAST (Analog Input only)
Adjusts the image displayed for non-standard video inputs.
AUTO ADJUST (Analog Input only)
Automatically adjusts the Image Position, the H. Size and Fine setting.
LEFT/RIGHT (Analog Input only)
Controls Horizontal Image Position within the display area of the LCD.
DOWN/UP (Analog Input only)
Controls Vertical Image Position within the display area of the LCD.
H. SIZE (Analog Input only)
Adjusts the horizontal size by increasing or decreasing this setting.
FINE (Analog Input only)
Improves focus, clarity and image stability by increasing or decreasing this setting.
COLOUR CONTROL SYSTEMS
Four colour presets (9300/7500/6500/USER) select the desired colour setting.
COLOUR RED
Increase or decreases Red. The change will appear on screen.
COLOUR GREEN
Increase or decreases Green. The change will appear on screen.
COLOUR BLUE
Increase or decreases Blue. The change will appear on screen.
TOOL
Selecting TOOL allows you to get into the sub menu.
FACTORY PRESET
Selecting Factory Preset allows you to reset all OSM control settings back to the factory settings. The RESET button
will need to be held down for several seconds to tage effect. Individual settings can be reset by highlighting the
control to be reset and pressing the RESET button.
EXIT
Selecting EXIT allows you exit OSM menu/ sub menu.
LANGUAGE
OSM control menus are available in seven languages.
OSM TURN OFF
The OSM control menu will stay on as long as it is in use. In the OSM Turn OFF submenu, you can select how
long the monitor waits after the last touch of a button to shut off the OSM control menu. The preset choices are
10 - 120 seconds by 5 seconds step.
English-7
OSM LOCK OUT
This control completely locks out access to all OSM control functions without Brightness and Contrast. When
attempting to activate OSM controls while in the Lock Out mode, a screen will appear indicating the OSM are
locked out. To activate the OSM Lock Out function, press “1<->2/ RESET”, then “+” key and hold down
simultaneously. To de-activate the OSM Lock Out, press “1<->2/ RESET”, then “+” key and hold down simultaneously.
RESOLUTION NOTIFIER
If ON is selected, a message will appear on the screen after 30 seconds, notifying you that the resolution is not at
optimal resolution.
MONITOR INFO
Indicates the model and serial numbers of your monitor.
OSM Warning
OSM Warning menus disappear with SELECT button.
NO SIGNAL: This function gives a warning when there is no signal present. After power is turned on or
when there is a change of input signal or video is inactive, the No Signal window will appear.
RESOLUTION NOTIFIER: This function gives a warning of use with optimized resolution. After power is
turned on or when there is a change of input signal or the video signal doesn’t have proper resolution, the
Resolution Notifier window will open. This function can be disabled in the TOOL menu.
OUT OF RANGE: This function gives a recommendation of the optimized resolution and refresh rate. After
the power is turned on or there is a change of input signal or the video signal doesn’t have proper timing,
the Out Of Range menu will appear.
English-8
Recommended use
Safety Precautions and Maintenance
FOR OPTIMUM PERFORMANCE, PLEASE NOTE
THE FOLLOWING WHEN SETTING UP AND
USING THE ACCUSYNC LCD COLOUR MONITOR:
•
DO NOT OPEN THE MONITOR. There are no user serviceable parts inside and opening or removing covers may expose
you to dangerous shock hazards or other risks. Refer all servicing to qualified service personnel.
•
•
Do not spill any liquids into the cabinet or use your monitor near water.
Do not insert objects of any kind into the cabinet slots, as they may touch dangerous voltage points, which can be harmful
or fatal or may cause electric shock, fire or equipment failure.
•
•
Do not place any heavy objects on the power cord. Damage to the cord may cause shock or fire.
Do not place this product on a sloping or unstable cart, stand or table, as the monitor may fall, causing serious damage to
the monitor.
•
•
When operating the LCD monitor with its AC 125-240V power supply, use a power supply aord that matches the power
supply voltage of the AC power outlet being used. The power supply cord you use must have been approved by and
comply with the safety standards of your country. (Type H05VV-F should be used in Europe).
In U.K, use a BS-approved power cord with molded plug having a black (5A) fuse installed for use with this monitor.
If a power cord is not supplied with this monitor, please contact your supplier.
•
•
Do not place any objects onto the monitor and do not use the monitor outdoors.
The inside of the fluorescent tube located within the LCD monitor contains mercury. Please follow the bylaws or rules of
your municipality to dispose of the tube properly.
•
•
•
Do not bend power cord.
Do not use monitor in high temperature, humid, dusty, or oily areas.
Do not cover vent on monitor.
Immediately unplug your monitor from the wall outlet and refer servicing to qualified service personnel under the following
conditions:
•
•
•
•
•
•
When the power supply cord or plug is damaged.
If liquid has been spilled, or objects have fallen into the monitor.
If the monitor has been exposed to rain or water.
If the monitor has been dropped or the cabinet damaged.
If the monitor does not operate normally by following operating instructions.
If monitor is broken, do not come in contact with the liquid crystal and handle with care.
•
Allow adequate ventilation around the monitor so that heat can properly dissipate. Do not block ventilated
openings or place the monitor near a radiator or other heat sources. Do not put anything on top of
monitor.
CAUTION
•
•
The power cable connector is the primary means of detaching the system from the power supply. The
monitor should be installed close to a power outlet, which is easily accessible.
Handle with care when transporting. Save packaging for transporting.
•
Image Persistence: Please be aware that LCD Technology may experience a phenomenon known as Image Persistence.
Image Persistence occurs when a residual or “ghost” image of a previous image remains visible on the screen. Unlike CRT
monitors, LCD monitors’ image persistence is not permanent, but constant images being displayed for a long period of
time should be avoided.
To alleviate image persistence, turn off the monitor for as long as the previous image was displayed. For example, if an
image was on the monitor for one hour and a residual image remains, the monitor should be turned off for one hour to
erase the image.
As with all personal display devices, NEC DISPLAY SOLUTIONS recommends displaying moving images and using a
moving screen saver at regular intervals whenever the screen is idle or turning off the monitor when not in use.
English-9
CORRECT PLACEMENT AND ADJUSTMENT OF THE MONITOR CAN
REDUCE EYE, SHOULDER AND NECK FATIGUE. CHECK THE
FOLLOWING WHEN YOU POSITION THE MONITOR:
•
•
For optimum performance, allow 20 minutes for warm-up.
Adjust the monitor height so that the top of the screen is at or slightly below eye level.
Your eyes should look slightly downward when viewing the middle of the screen.
•
Position your monitor no closer than 40 cm and no further away than 70 cm from your
eyes. The optimal distance is 50 cm.
•
•
Rest your eyes periodically by focusing on an object at least 6 m away. Blink often.
Position the monitor at a 90° angle to windows and other light sources to minimize glare
and reflections. Adjust the monitor tilt so that ceiling lights do not reflect on your screen.
•
•
•
•
If reflected light makes it hard for you to see your screen, use an antiglare filter.
Adjust the monitor’s brightness and contrast controls to enhance readability.
Use a document holder placed close to the screen.
Position whatever you are looking at most of the time (the screen or reference material) directly in front of you to minimize
turning your head while you are typing.
•
•
Avoid displaying fixed patterns on the monitor for long periods of time to avoid image persistence (after-image effects).
Get regular eye checkups.
Ergonomics
To realize the maximum ergonomics benefits, we recommend the following:
•
•
•
•
Use the preset Size and Position controls with standard signals.
Use the preset Colour Setting.
Use non-interlaced signals with a vertical refresh rate between 60-75 Hz.
Do not use primary colour blue on a dark background, as it is difficult to see and may produce eye fatigue to insufficient
contrast.
Cleaning the LCD Panel
•
•
•
•
When the liquid crystal panel is stained with dust or dirt, please wipe with soft cloth gently.
Please do not rub the LCD panel with hard material.
Please do not apply pressure to the LCD surface.
Please do not use OA cleaner it will cause deterioration or discolor on the LCD surface.
Cleaning the Cabinet
•
•
•
Unplug the power supply
Gently wipe the cabinet with a soft cloth
To clean the cabinet, dampen the cloth with a neutral detergent and water, wipe the cabinet and follow with a dry cloth.
NOTE:
Many plastics are used on the surface of the cabinet. DO NOT clean with benzene, thinner, alkaline detergent,
alcoholic system detergent, glass cleaner, wax, polish cleaner, soap powder, or insecticide. Do not touch rubber or
vinyl to the cabinet for a long time. These types of fluids and fabrics can cause the paint to deteriorate, crack or
peel.
English-10
Specifications for AccuSync LCD72XM
Monitor Specifications
AccuSync LCD72XM Monitor
Notes
LCD Module
Diagonal: 43 cm/17 inches
Viewable Image Size: 43 cm/17 inches
Active matrix; thin film transistor (TFT)
liquid crystal display (LCD); 0.264 mm dot
pitch; 250 cd/m2 white luminance,
450:1 contrast ratio, typical;
Native Resolution (Pixel Count): 1280 x 1024
response time: 8 ms.
Input Signal
Video: ANALOG 0.7 Vp-p/75 Ohms
Digital Input: DVI
Sync: Separate sync.TTL Level (Positive/Negative)
Horizontal sync. Positive/Negative
Vertical sync. Positive/Negative
Display Colours
Analog input: 16,2 M
Depends on display card used.
Synchronization Range
Horizontal: 31.5 kHz to 81.1 kHz
Vertical: 55 Hz to 76 Hz
Automatically
Automatically
Viewing Angle
Left/Right: -70°/+70°(CR>10)
Up/Down: -65°/+60°(CR>10)
Resolutions Supported Landscape: 720 x 400*1 : VGA
Some systems may not
support all modes listed.
640 x 480*1 @ 60 Hz to 75 Hz
800 x 600*1 @ 56 Hz to 75 Hz
832 x 624*1 @ 75 Hz
1024 x 768*1 @ 60 Hz to 75 Hz
1152 x 864*1 @ 70 Hz
1152 x 870*1 @ 75 Hz
1280 x 960*1 @ 60 Hz to 75 Hz
Recommended resolution is 60 Hz for
1280 x 1024 @ 60 Hz to 75 Hz................... optimal display performance.
Horizontal: 337.9 mm
Vertical: 270.3 mm
Practical Audio Output: 1.0 W + 1.0 W
100 - 240 V ~ 50/60 Hz
34 W
Active Display Area
Speakers
Power Supply
Power Consumption
Dimensions
Landscape: 375.4 mm (W) x 389.0 mm (H) x 180 mm (D) (with stand)
375.4 mm (W) x 326.5 mm (H) x 61 mm (D) (without stand)
Weight
4.7 kg
Environmental Considerations
Operating Temperature: 5 °C to 35 °C
Humidity: 30% to 80%
Altitude: 0 to 3,048 m
Storage Temperature: -10 °C to +60 °C
Humidity: 10% to 85%
Altitude: 0 to 12,192 m
*1 Interpolated Resolutions: When resolutions are shown that are lower than the pixel count of the LCD module, text may appear different. This is
normal and necessary for all current flat panel technologies when displaying non-native resolutions full screen. In flat panel technologies, each dot on
the screen is actually one pixel, so to expand resolutions to full screen, an interpolation of the resolution must be done.
NOTE:
Technical specifications are subject to change without notice.
English-11
Specifications for AccuSync LCD92XM
Monitor Specifications
AccuSync LCD92XM Monitor
Notes
LCD Module
Diagonal: 46.26 cm/19 inches
Active matrix; thin film transistor (TFT)
liquid crystal display (LCD); 0.294 mm dot
pitch; 270 cd/m2 white luminance,
550:1 contrast ratio, typical;
Viewable Image Size: 46.26 cm/19 inches
Native Resolution (Pixel Count): 1280 x 1024
response time: 8 ms.
Input Signal
Video: ANALOG 0.7 Vp-p/75 Ohms
Sync: Separate sync.TTL Level (Positive/Negative)
Horizontal sync. Positive/Negative
Digital Input: DVI
Vertical sync. Positive/Negative
Display Colours
Analog input: 16,2 M
Depends on display card used.
Synchronization Range
Horizontal: 31.5 kHz to 81.1 kHz
Vertical: 55 Hz to 76 Hz
Automatically
Automatically
Viewing Angle
Left/Right: -70°/+70°(CR>10)
Up/Down: -65°/+60°(CR>10)
Resolutions Supported Landscape: 720 x 400*1 : VGA
Some systems may not
support all modes listed.
640 x 480*1 @ 60 Hz to 75 Hz
800 x 600*1 @ 56 Hz to 75 Hz
832 x 624*1 @ 75 Hz
1024 x 768*1 @ 60 Hz to 75 Hz
1152 x 864*1 @ 70 Hz
1152 x 870*1 @ 75 Hz
1280 x 960*1 @ 60 Hz to 75 Hz
Recommended resolution is 60 Hz for
1280 x 1024 @ 60 Hz to 75 Hz................... optimal display performance.
Horizontal: 376.3 mm
Vertical: 301.1 mm
Practical Audio Output: 1.0 W + 1.0 W
100 - 240 V ~ 50/60 Hz
40 W
Active Display Area
Speakers
Power Supply
Power Consumption
Dimensions
Landscape: 418.0 mm (W) x 427.8 mm (H) x 199.5 mm (D) (with stand)
418.0 mm (W) x 369.5 mm (H) x 68.0 mm (D) (without stand)
Weight
6.5 kg
Environmental Considerations
Operating Temperature: 5 °C to 35 °C
Humidity: 30% to 80%
Altitude: 0 to 3,048 m
Storage Temperature: -10 °C to +60 °C
Humidity: 10% to 85%
Altitude: 0 to 12,192 m
*1 Interpolated Resolutions: When resolutions are shown that are lower than the pixel count of the LCD module, text may appear different. This is
normal and necessary for all current flat panel technologies when displaying non-native resolutions full screen. In flat panel technologies, each dot on
the screen is actually one pixel, so to expand resolutions to full screen, an interpolation of the resolution must be done.
NOTE:
Technical specifications are subject to change without notice.
English-12
Features
Reduced Footprint: Provides the ideal solution for environments requiring superior image quality but with size and weight
limitations. The small footprint and low weight allow it to be moved or transported easily from one location to another.
Colour Control System: Allows you to adjust the colours on your screen and customize the colour accuracy of your monitor
to a variety of standards.
OSM (On-Screen Manager) Controls: Allow you to quickly and easily adjust all elements of your screen image via simple to
use on-screen menus.
No-touch Auto Adjust: No-touch Auto Adjust automatically adjusts the monitor to optimal settings upon initial setup.
ErgoDesign Features: Enhance human ergonomics to improve the working environment, protect the health of the user and
save money. Examples include OSM controls for quick and easy image adjustments, tilt base for preferred angle of vision,
small footprint and compliance with MPRII and TCO guidelines for lower emissions.
Plug and Play: The Microsoft solution with the Windows 95/98/Me/2000/XP operating system facilitates setup and installation
by allowing the monitor to send its capabilities (such as screen size and resolutions supported) directly to your computer,
automatically optimizing display performance.
IPM (Intelligent Power Manager) System: Provides innovative power-saving methods that allow the monitor to shift to a
lower power consumption level when on but not in use, saving two-thirds of your monitor energy costs, reducing emissions
and lowering the air conditioning costs of the workplace.
Multiple Frequency Technology: Automatically adjusts monitor to the display card’s scanning frequency, thus displaying the
resolution required.
FullScan Capability: Allows you to use the entire screen area in most resolutions, significantly expanding image size.
VESA Standard Mounting Interface: Allows users to connect their AccuSync monitor to any VESA standard third party
mounting arm or bracket. Allows for the monitor to be mounted on a wall or an arm using any third party compliant device.
English-13
Troubleshooting
No picture
•
•
•
•
The signal cable should be completely connected to the display card/computer.
The display card should be completely seated in its slot.
Check front power Switch and computer power switch should be in the ON position.
Check to make sure that a supported mode has been selected on the display card or system being used. (Please
consult display card or system manual to change graphics mode.)
•
•
•
Check the monitor and your display card with respect to compatibility and recommended settings.
Check the signal cable connector for bent or pushed-in pins.
Check the signal input.
Power Button does not respond
Unplug the power cord of the monitor from the AC outlet to turn off and reset the monitor.
•
Image persistence
Please be aware that LCD Technology may experience a phenomenon known as Image Persistence. Image
•
Persistence occurs when a residual or “ghost” image of a previous image remains visible on the screen. Unlike CRT
monitors, LCD monitors’ image persistence is not permanent, but constant images being displayed for a long period of
time should be avoided.
To alleviate image persistence, turn off the monitor for as long as the previous image was displayed. For example, if an
image was on the monitor for one hour and a residual image remains, the monitor should be turned off for one hour to
erase the image.
As with all personal display devices, NEC DISPLAY SOLUTIONS recommends displaying moving images and using a
moving screen saver at regular intervals whenever the screen is idle or turning off the monitor when not in use.
Image is unstable, unfocused or swimming is apparent
•
Signal cable should be completely attached to the computer.
•
Use the OSM Image Adjust controls to focus and adjust display by increasing or decreasing the fine total. When the
display mode is changed, the OSM Image Adjust settings may need to be re-adjusted.
•
•
Check the monitor and your display card with respect to compatibility and recommended signal timings.
If your text is garbled, change the video mode to non-interlace and use 60 Hz refresh rate.
LED on monitor is not lit (no green or amber colour can be seen)
Power Switch should be in the ON position and power cord should be connected.
•
Display image is not sized properly
•
Use the OSM Image Adjust controls to increase or decrease the H.SIZE.
•
Check to make sure that a supported mode has been selected on the display card or system being used.
(Please consult display card or system manual to change graphics mode.)
No Video
•
If no video is present on the screen, turn the Power button off and on again.
•
Make certain the computer is not in a power-saving mode (touch the keyboard or mouse).
No Sound
•
•
•
Check to see if speaker cable is properly connected.
Check to see if mute is activated.
Check to see if volume in OSM is set at minimum.
English-14
TCO’03
Congratulations!
The display you have just purchased carries the TCO’03 Displays
label. This means that your display is designed, manufactured and
tested according to some of the strictest quality and environmental
requirements in the world. This makes for a high performance
product, designed with the user in focus that also minimizes the
impact on our natural environment.
Some of the features of the TCO’03 Display requirements:
Ergonomics
• Good visual ergonomics and image quality in order to improve the working environment for
the user and to reduce sight and strain problems. Important parameters are luminance,
contrast, resolution, reflectance, colour rendition and image stability.
Energy
• Energy-saving mode after a certain time – beneficial both for the user and the environment
• Electrical safety
Emissions
• Electromagnetic fields
• Noise emissions
Ecology
• The product must be prepared for recycling and the manufacturer must have a certified
environmental management system such as EMAS or ISO 14 001.
• Restrictions on:
- chlorinated and brominated flame retardants and polymers
- heavy metals such as cadmium, mercury and lead.
The requirements included in this label have been developed by TCO Development in co-
operation with scientists, experts, users as well as manufacturers all over the world. Since the
end of the 1980s TCO has been involved in influencing the development of IT equipment in a
more user-friendly direction. Our labelling system started with displays in 1992 and is now
requested by users and IT-manufacturers all over the world.
For more information, please visit
English-15
Manufacturer’s Recycling and Energy Information
NEC DISPLAY SOLUTIONS is strongly committed to environmental protection and sees recycling as one of the company’s
top priorities in trying to minimize the burden placed on the environment. We are engaged in developing environmentally-
friendly products, and always strive to help define and comply with the latest independent standards from agencies such as
ISO (International Organisation for Standardization) and TCO (Swedish Trades Union).
For more information, and for help in recycling your old NEC monitors, please visit our website at
Country-specific recycling programmes can also be found at:
Sweden -
Germany -
Holland -
Japan -
Energy saving:
This monitor features an advanced energy saving capability. When a VESA Display Power Management Signaling (DPMS)
Standard signal is sent to the monitor, the Energy Saving mode is activated. The monitor enters a single Energy Saving mode.
LCD72XM
Mode
Power consumption
Approx. 34W
LED colour
Green
Normal Operation
Energy Saving Mode
Off Mode
Less than 2W
Orange
Unlit
Less than 2W
LCD92XM
Mode
Power consumption
Approx. 40W
LED colour
Green
Normal Operation
Energy Saving Mode
Off Mode
Less than 2W
Orange
Unlit
Less than 2W
Disposing of your old NEC product
Within the European Union
EU-wide legislation, as implemented in each Member State, requires that waste electrical and
electronic products carrying the mark (left) must be disposed of separately from normal household
waste. This includes monitors and electrical accessories, such as signal cables or power cords. When
you need to dispose of your NEC display products, please follow the guidance of your local authority,
or ask the shop where you purchased the product, or if applicable, follow any agreements made
between yourself and NEC.
The mark on electrical and electronic products only applies to the current European Union Member
States.
Outside the European Union
If you wish to dispose of used electrical and electronic products outside the European Union, please contact your local
authority so as to comply with the correct disposal method.
English-16
|